Home
        manual ultrasonic cleaner pce-uc series
         Contents
1.    Instruments    PCE Americas Inc  PCE Instruments UK Ltd   711 Commerce Way Units 12 13  Suite 8 Southpoint Business Park  Jupiter Ensign way  FL 33458 Hampshire   Southampton  USA United Kingdom  S031 4RF  From outside US   1 From outside UK   44  Tel   561  320 9162 Tel   0  2380 98703 0  Fax   561  320 9176 Fax   0  2380 98703 9  info pce americas com info pce instruments com    www pce instruments com english  www pce instruments com    Manual    Ultrasonic Cleaner PCE UC Series                     Se   aes Bee W   ISS   4      R rman       De Mn    a      eins       Version 1 0    Date of creation  02 02 2015  Date of last change  17 04 2015    Manual PCE Instruments    Contents   ROCCO E E E E EEE E A E EA 3  1 1 Ee TTT 3  1 2 BIS NES TTT qraatena Giaeunatiavetsndauad mer eniean E E 3  2 MAIV TIO COS acne cones a ae dns ne ee us ne 4  3 ODOCITICAUIONS  een san san en sean ea aaia 5  4 SNSI  MACSCFTIDHON            nes sese nenen enen 6  IS TEUCHIONS nc nesnea aan ee ee 8  5 1 CA Earle TT 8  5 2 Starting the ultrasonic cleaning function    ss 8  5 3 Staring ie heating ACTOR ee a ete a ox 8  5 4 Finishing the cleaning process    eee ee eee ee 8  5 5 Cleaning OPUONS DR EO aE E Aae 8  6 sir c  tee tees tees ees ete eee ee cteee is se se ee Ua eectsee ben ees tees deueseesiees beeeseeetseeeseee 9  E e   lt   AS Uae ace ne Se ice ntas 9  7 1 PO STRUT OILS WON sees a aan a ton aan ten a nono 9  7 2 POE AMENG ee ee eee eee 9    NO    PCE instruments Manual       1 Introductio
2.   1 x PCE UC device  1 x cover   1 x mains cable   1 x outlet filter   1 x mesh basket    Take the ultrasonic cleaner out of the packaging and check whether the appropriate mains cable and the  listed accessories are included  Keep the packaging for storage of the device or for the unlikely case that  you have to send the product back for repair     Manual PCE Instruments       2 Safety notes   Please read this manual carefully and completely before you use the device for the first time  The device  may only be used by qualified personnel and repaired by PCE Instruments personnel  There is no  warranty of damages or injuries caused by non observance of the manual       The device may only be used in approved temperature ranges      The case should only be opened by qualified personnel of PCE Instruments      The instrument should never be placed with the user interface facing an object  e g  keyboard side ona  table       You must not make any technical changes to the device      The appliance should only be cleaned with a damp cloth   use only pH neutral cleaner  no abrasives or  solvents      Never operate the ultrasonic cleaner for longer than one complete cleaning cycle  99 minutes  as this  might cause damage to the device      Never use the device without any liquid in the cleaning tank  Always make sure that the level of liquid is  between the minimum and the maximum marking      Be careful when you place the products in the cleaning tank and always use the basket  if 
3. 8 x 11 81 x 7 87     180 x 165 x 230 mm 530 x 165 x 310 mm 530 x 330 x 380 mm    7 09 x 6 50 x 9 05     20 89 x 6 50 x 12 20       20 89 x 12 99 x 14 96            Manual PCE Instruments       4 System description       LED display   heating temperature indication  safety precautions  temperature setting  heater on   off  cleaner on   off  timer setting   drain valve   lifting handle   LED display   timer  LED   cleaner   LED   heater            OONOOOfWND                   PCE Instruments Manual       Manual PCE Instruments    5 Instructions    5 1 Getting started    1  Make sure that the ultrasonic cleaner is placed on a clean and even surface   2  Ensure that the mains cable is correctly connected to the ultrasonic cleaner and that there is no liquid  at the junction     5 2 Starting the ultrasonic cleaning function    1  Fill the cleaning tank with water  at least half full    2  Connect the ultrasonic cleaner to the power supply system    3  Set the cleaning time by means of the    timer setting    keys   Up  increase time  Down  decrease time   4  Press the    cleaner on   off    key to start cleaning  The remaining cleaning time is displayed in the timer  display in minutes and seconds     5 3 Starting the heating function    1  Set the temperature by means of the    temperature setting    keys   Up  increase temperature  Down  decrease temperature  Press the    heater on  off    key to start the heating function     5 4 Finishing the cleaning process    1  When the de
4. n    1 1 General    Thank you for purchasing an ultrasonic cleaner of the PCE UC series from PCE Instruments    Our PCE UC series ultrasonic cleaners have a resilient industrial grade tank made of stainless steel   which is equipped with a circuit board that is insulated against humidity  If handled properly  this device  will render good service for many years    Ultrasonic cleaners work on the basis of the phenomenon called cavitation which means that pressure  fluctuations inside the cleaning liquid are created by means of ultrasound  These fluctuations in pressure  cause small cavities filled with vapour  As the pressure returns to normal  the bubbles collapse and the  liquid suddenly returns to the cavity  Note that extreme pressure surges may occur during a short period  of time  The ultrasonic cleaner uses these pressure surges to clean surfaces    Ultrasonic cleaners can be used for various purposes  e  g  for cleaning      spray guns   vehicle   plane components     calligraphy brushes and tips   plotter pens   tips     surgical and dental instruments   injection nozzles     geological and metallurgical samples   injection needles     printer cartridges   lenses and other optical components    laboratory glass instruments and appliances   metal and rubber seals     metal   fibre filters   scientific instruments     micro electronic circuits and components   spectacle frames and lenses     spray nozzle   circuit boards     watches   jewellery    1 2 Delivery content  
5. possible  as  otherwise the cleaning tank might be damaged      Ensure that the products in the cleaning tank are non contacting as this would deteriorate the result  substantially      Keep the cover closed during cleaning to avoid splashing and evapouration      Disconnect the device from the circuit before filling it      Make sure that the fan on the bottom side of the cleaner is not covered      Always turn off the heater after cleaning in order to avoid evapouration of the cleaning liquid      Never operate the device when your hands are wet      Only use this device with PCE accessories or equivalent      Before use  check the case for visible damage  In case any damage is visible  do not use the device      Do not use the device in explosive atmospheres      If you do not observe these safety notes  this might cause damage to the device or injury to the user     This manual is published from PCE Instruments without any guarantee   We expressly point to our general guarantee terms which can be found in our general terms of business     If you have any questions please contact PCE Instruments     PCE Instruments Manual    3 Specifications    PCE UC 20 PCE UC 100 PCE UC 270    Cleaning 50 W 200 W 500 W  capacity  RE H a    0   80   C  0     176 F  0   20   C  0  176 F  0   80   C  0     176 F     Time settings  40 KHz E KHz 40 KHz  Dimensions    gt     Cleaning tank 150 x 140 x 100 mm 505 x 135 x 150 mm 500 x 300 x 200 mm   5 90 x 5 51 x 3 94   19 88 x 5 31 x 5 90   19 6
6. vice is on  press the    cleaner on   off    key to finish the cleaning process   2  When the heater is on  press the    heater on   off    key to finish the heating function   3  Disconnect the device from the power supply system    4  Empty the cleaning tank    5  Clean the inside as well as the outside of the device thoroughly with a dry cloth     5 5 Cleaning options    1  Standard cleaning  Use only tap water at a temperature of more than 50   C  122   F    2  Improved cleaning  Add a few drops of    non acid    cleaning agent to the water  e  g  liquid soap    3  Extensive cleaning  If you wish to clean stubborn dirt accumulations extensively  we recommend to add a special ultrasonic  cleaning solution to the water bath  Check our website for appropriate cleaning solutions     Warning  The use of high acid or alkaline cleaning liquids will cause corrosion and damage to the  cleaning tank and other components of the device     PCE Instruments Manual    6 Disposal   For the disposal of batteries  the 2006 66 EC directive of the European Parliament applies  Due to the  contained pollutants  batteries must not be disposed of as household waste  They must be given to  collection points designed for that purpose     In order to comply with the EU directive 2012 19 EU we take our devices back  We either re use them or  give them to a recycling company which disposes of the devices in line with law     If you have any questions  please contact PCE Instruments     7 Contact  If 
7. you have any questions about our range of products or measuring instruments please contact PCE  Instruments     7 1 PCE Instruments UK    By post    PCE Instruments UK Ltd    Units 12 13 Southpoint Business Park  Ensign Way  Southampton  Hampshire    United Kingdom  SO31 4RF    By phone   02380 987 035    7 2 PCE Americas    By post    PCE Americas Inc   711 Commerce Way  Suite 8   Jupiter   33458 FL   USA    By phone   561 320 9162       Ad    www pce insiruments com       
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Porte soufflante modèle Q46 - La Centrale du Diagnostiqueur    Olympus Fluoview FV1000 User's Manual  土地改良施設管理基準 − 排水機場編− 基準(案)対比表 平成20年3月  Philips 871150066272910 energy-saving lamp      Inhaltsverzeichnis  KitchenAid KEMS377B User's Manual  Samsung WA16A2Q3 Manual de Usuario    Copyright © All rights reserved. 