Home
User Manual - ADFWeb.com
Contents
1. Ledi Green Power ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 9 of 22 Industrial Electronic Devices HD67575 Al1 WITH C S B150 LED Normal Mode Boot Mode l l l Blinks quickly Boot state 1 Ethernet comm green Blinks quickly when receive Ethernet commands i l Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state 2 Device State green Blinks slowly 1Hz l Blinks very slowly 0 5Hz update in progress i l l Blinks quickly Boot state 3 PROFIBUS comm green Blinks quickly when there is PROFIBUS communication Blinks very slowly 0 5Hz update in progress ON Powered ON Powered 4 Power green OFF Not powered OFF Not powered ON Ethernet cable connected ON Ethernet cable connected 5 Ethernet Link green OFF Ethernet cable disconnected OFF Ethernet cable disconnected Led3 Led2 Ledi Green Green Green r PROFIBUS comm Device State Ethernet comm o Ei cece ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices PROFIBUS The PROFIBUS uses a 9 pin D SUB connector The pin assignment is defined like in the right figure Here some codes of cables Belden p n 183079A Continuous Armor DataBus ISA SP 50 PROFIBUS Cable User Manual Eth
2. Industrial Electronic Devices User Manual Revision 1 010 English Ethernet Server from to PROFIBUS Master Order Code HD67575 A1 for Website information http www adfweb com Product HD67575 for Price information http www adfweb com Price HD67575 Al Benefits and Main Features Very easy to configure Low cost Industrial temperature range 40 C 85 C 40 F 185 F ADFweb com Srl IT31010 Mareno Treviso User Manual Document code MN67575_ENG Ethernet Server from to PROFIBUS Master Revision 1 010 Page 1 of 22 For others PROFIBUS devices see also the following links PROFIBUS Slave from to www adfweb com Product HD67045 www adfweb com Product HD67053 www adfweb com Product HD67551 www adfweb com Product HD67552 www adfweb com Product HD67553 www adfweb com Product HD67554 www adfweb com Product HD67555 www adfweb com Product HD67561 www adfweb com Product HD67562 www adfweb com Product HD67563 www adfweb com Product HD67564 www adfweb com Product HD67565 Do you have an your customer protocol See the following links www adfweb com Product HD67003 SL LON LON LON LON ON LOO EN EON CNN G G C C Serial M Bus Master CANopen CAN J1939 DeviceNet Slave DeviceNet Master Modbus Master Modbus Slave Ethernet Server Modbus TCP Client Modbus TCP Server Do you need to choose a device
3. Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode Figure 6 Update Device windows FIRMWARE OK PROJECT OK At this point the configuration firmware on the device is correctly update Note A When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67575 A1 device Warning If the Fig 7 appears when you try to do the Update before require assistance try these points Try to repeat the operations for the updating Try with another PC Try to restart the PC io Semen If you are using the program inside a Virtual Machine try to use in the main FIRMWARE PROTECTION Operating System If you are using Windows Seven or Vista make sure that you have the administrator privileges Take attention at Firewall lock Check the LAN settings Wer 1 001 PROJECT PROTECTION Figure 7 Protection window In the case of HD67575 A1 you have to use the software SW67575 www adfweb com download filefold SW67575 zip ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 16 of 22 Industrial Electronic Devices ETHERNET PROTOCOL This protocol has got a single function for write and or read fr
4. 00 00 Response 03 14 00 OF F4 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 20 42 3F 00 01 42 3F 00 02 42 3F 00 03 42 33 00 04 82 3F 00 05 82 3F 00 06 82 3F 00 07 82 33 00 08 00 00 Example3 Request to get data from address PROFIBUS 21 and writing of 5 bytes In this case the Byte3 gives No Error response for writing Request 14 01 05 01 02 03 04 05 Response 03 14 01 OF F4 11 22 33 44 55 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
5. 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 20 42 3F 00 01 42 3F 00 02 42 3F 00 03 42 33 00 04 82 3F 00 05 82 3F 00 06 82 3F 00 07 82 33 00 08 00 00 Example4 Request to get data from address PROFIBUS 21 and writing of 5 bytes but only four bytes are written in the request In t his case the Byte3 gives an error response for writing Request 14 01 05 01 02 03 04 Response 03 14 05 OF F4 11 22 33 44 55 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 20 42 3F 00 01 42 3F 00 02 42 3F 00 03 42 33 00 04 82 3F 00 05 82 3F 00 06 82 3F
6. 00 07 82 33 00 08 00 00 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 19 of 22 Industrial Electronic Devices EXTENDED MODE The Extended Protocol is enabled by adding a 0x80 to Byte Number 1 The request include the following byte Byte Number n Number of Byte to Write If the Number of Byte to Write n has got the value 0x00 there are no data to write The response includes the following byte Byte Number Abbreviation Description DLR 7 DLR CLP 6 DLR CLP 7 DLR CLP 8 DLR CLP DLW 7 DLR CLP DLW 9 DLR CLP DLW CLD 8 Configuration of device Pp DIR CLUP DLW CLD 9 sd FixedaatO OoOo ee A S ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 20 of 22 Industrial Electronic Devices The Writing state Byte 3 can have these values 0x00 0x01 0x02 0x03 0x04 0x05 Writing not required No error Slave does not exist or does not respond in time or is not connected to line Writing not possible because the start byte is too big Writing cannot be made because the length is too high The data sent are insufficient for writ
7. 2 Coy Update Device www ADFweb com Figure 2 Main window for SW67575 NEW PROJECT OPEN PROJECT The New Project button creates the folder which contains the entire device configuration i Select directory of project Pro j ect name Example b Berg DCMI t BGA Beetz b 9 BIOGAS_Strullendorf b p Colinkeane_ SonothermSN3003 revi p Wii Copia di ABB DELTAplus A device configuration can also be imported or exported t Copy 3 of ENTALPIA_HS532 e Double Zenner Zelsius To clone the configurations of a Programmable Ethernet Server from to PROFIBUS Master b jy ECB Gateway in order to configure another device in the same manner it is necessary to p Wt ECE Corrected maintain the folder and all its contents E aen To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another name and open the new folder with the button Open Project ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG_ Revision 1 010 Page 12 of 22 Industrial Electronic Devices SET COMMUNICATION SET COMMUNICATION i This section defines the fundamental communication parameter of two buses PROFIBUS and Ethernet nae By pressing the Set Communication button from the main window for SW67575 Fig 2 the wind
8. 2 Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate PRODUCTS AND RELATED DOCUMENTS Part Description URL HD67181 CAN bus Repeater www adfweb com product HD67181 HD67316 CAN bus Analyzer www adfweb com product HD67316 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31
9. B153 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 4 of 22 Industrial Electronic Devices Connector1 Power Supply port OV Ground V Positive wire V AC min 8V max 24V E E m V DC min 12V max 35V HUHI OV V Rail DIN a I OSTA SZSZ9NW ZE ZT TVSZSZ90H FE CO 20 23 F9 0T OVH Me Pama faa clamp ny3 apop 20g apogawea aonad LOTEG IN HES uwos snaisoyd 011 O amod KOI 0O n TW S2S290H woxqansqyMmm lll ll Ill h ll Ih IIl Ill Il Mon E sand eW SNEIIOUd O1 Wod JausayyZ ABMa D SUB9 Female p d 30 ASEM TT PIN3 wire A oyes i PINS GND ae l Figure 1b Connection scheme for HD67575 A1 with c s B150 PINS wire B 54321 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Document code MN67575_ENG Industrial Electronic Devices CHARACTERISTICS Ethernet Server from to PROFIBUS Master The configurable Ethernet Server from to PROFIBUS Master gateway allows the following characteristics iF F F F TCP IP and UDP protocol at Ethernet side Mountable on 35mm Rail DIN Power Supply 8 24V AC or 12 35V DC Temperature range 40 C to 85 C CONFIGURATION You need Compositor SW67575 software on your PC in order to perform the following ka
10. do you want help Ask it to the following link www adfweb com Cmd helpme INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices INDEX INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS CONNECTION SCHEME CHARACTERISTICS CONFIGURATION POWER SUPPLY FUNCTION MODES LEDS PROFIBUS ETHERNET USE OF COMPOSITOR SW67575 NEW PROJECT OPEN PROJECT SET COMMUNICATION PROFIBUS NETWORK UPDATE DEVICE ETHERNET PROTOCOL MECHANICAL DIMENSIONS ORDER CODE ACCESSORIES WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY PRODUCTS AND RELATED DOCUMENTS ADFweb com Srl IT31010 Mareno Treviso Page es ee oe NEB OOMNAUUMWNNNNN 13 User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 2 of 22 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code and download the updates To obtain the updated documentation for the product that you own note the Document Code Abbreviated written Doc Co
11. 2 WORD Slave Out Master In i 3 WORD Slave Out Master In 4 WORD Slave Out Master In 5 WORD Slave Out Master In 6 WORD Slave Out Master In 7 WORD Slave Out Master In 8 WORD Slave Out Master In Maximum Value I O in use Configuration Data ex Op ai ae 00 01 02 03 04 05 06 07 08 09 0A oB 0c OD OF OF Max Output 244 Output 2 Max Data 488 Max Modules 244 Figure 5 PROFIBUS Device window V ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Figure 4 PROFIBUS Network window AL Industrial Electronic Devices User Manual Ethernet Server from to PROFIBUS Master UPDATE DEVICE Document code MN67575_ENG Revision 1 010 Page 14 of 22 By pressing the Update Device button it is possible to load the created Configuration into the device and also the Firmware if is necessary If you don t know the actual IP address of the device you have to use this procedure HD67575 Al1 WITH C S B153 ka ka ka Turn off the Device Put Dip2 of Dip Switch A at ON position Insert the IP 192 168 2 205 Turn on the device Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device Put Dip2 o
12. 20 ASE et 19 JV AbT S AO At Ayddns samod Housing PVC Weight 200g Approx 120 mm 4 72 inch f ESTA S SLONW ZE ZE bE 00 L0 Z3 9 01 IVW E een ena ES 7S apo 20g 3p03 ajyeq LOTEG N jeas c V IPIMS dIA aio Q E a O O SHO TV SZSZ9GH worqgamyay mmm in O ey T ma gt a M il h NN UH Ill Mtl Moon B EY SEW SNAIFONd OF WOd PWI User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 21 of 22 RBI 0 9 inch Figure 8 Mechanical dimensions scheme Gateway Ethernet TCP IP UDP Server from to PROFIBUS Master Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Rail DIN Power Supply 110V AC 50 60Hz 12 V AC ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 22 of 22 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following 1 Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem
13. Slave PROFIBUS you must write the PROFIBUS address of your slave In the section Available modules there are all the modules you can select for this slave to add a modules you can select it and click on the hands or with a double click on the module o HD67575 PROFIBUS MASTER Add Slave PROFIBUS EL6731 0010 ID 2 Model Name EL6731 0010 Modify Stave PROFIBUS Vendor Name BECKHOFF Ident Number 0x095F Prm Data Len 237 Prm Data 0x08 Number Input 2 Number Output 2 Modules Conf Configured from GSD file HD67552 ID 1 Model Name HD67552 Vendor Name ADFweb com Ident Number OxAFF9 Prm Data Len 12 Prm Data 0x00 0x00 0x00 Number Input 71 Number Output 64 Modules Conf Configured from GSD file If the field Use modules configuration readed from device is checked the HD67575 A1 uses the configuration inside the slave device and not the one loaded with the gsd file ID Slave PROFIBUS 2 i Module Selection Model Name EL6731 0010 Vendor Name BECKHOFF Ident Number 0x095F Prm Data Len 237 Prm Data 0x08 E Use modules configuration readed from device Select Modules Available modules stot name Timpu Output tadd oada mame 1 1WORD Slave Out Master In 2 o 1 BYTE Slave Out Master In 2 1 WORD Slave In Master Out 0 2 g 1 WORD Slave Out Master In
14. ames This routine can use both the UDP protocol and the TCP by setting the parameter wanted with the SW67575 Compositor STANDARD MODE The request include the following byte Byte Number Address PROFIBUS Slave Number of Byte to Write n 4 4 n 1 Data Write n Number of Byte to Write Starting Address Write If the Number of Byte to Write n has got the value 0x00 there are no data to write The response includes the following byte po CByte Number Description Abbreviation a Address PROFIBUS Master Z po Address PROFIBUS Slave Writing state S A o 4 Slave informations 7A So Bata tength read DIR 6 DLR 5 Data read o o o l A o DLR 6 Configuration length programmed CLP 1 DLR 7 DLR CLP 6 Configuration programmed ofl EU FixedatO o S A Oo DLR CLP 7 Fixed at 0 PER CLP HF C SOCS DLR CLP 8 Fixed at 0 ld ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 17 of 22 Industrial Electronic Devices The Writing state Byte 3 can have these values 0x00 0x01 0x02 0x03 0x04 0x05 Writing not required No error Slave does not exist or does not respond in time or is not connected to line Writing not possible because the start byte is too big Writing cannot be made bec
15. ause the length is too high The data sent are insufficient for writing The Slave informations Byte 4 gives informations about the slave interrogated Every bit has a meaning BitO Configuration corresponds Bitl Parameters OK Bit2 Configuration OK Bit3 Data OK If all is correct you have to read OxOF Examplel Request to get data from address PROFIBUS 21 without writing nothing Request 15 00 00 Response 03 15 00 OF BA 27 28 45 65 71 00 00 00 00 00 00 00 00 6B 04 00 00 1A 00 00 00 00 00 A1 11 00 00 00 00 00 00 00 00 6B 04 00 00 1A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 27 28 45 65 71 00 00 00 00 00 00 00 00 6B 04 00 00 1A 00 00 00 00 00 A1 11 00 00 00 00 00 00 00 00 6B 04 00 00 1A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 36 10 13 13 13 1313 1313 13 1313 131313111113 111113 13 1113 13 fel LOS tele le leis ieee ie le lols S i aS boa lS 13800 00 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 18 of 22 Industrial Electronic Devices Example2 Request to get data from address PROFIBUS 20 without writing nothing Request 14
16. de on the label on the product and download the updated from our web site www adfweb com download REVISION LIST Revision Date Author Chapter Description 1 000 07 11 2011 Fl All First release version 1 010 16 03 2012 Fl All Software changed v1 101 WARNING ADFweb com reserves the right to change information in this manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS All trademarks mentioned in this document belong to their respective owners INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 3 of 22 Industrial Electronic Devices CONNECTION SCHEME Connectori Power Supply port OV Ground V Positive wire min 8V max 24V a EE gt min 12V max 35V HNN OV V ESTE SZSZ9NH t pe gOdOTI tO OVW wwo puana z071 O 7S2 apop IO apog apd LOTEA N EHAS ayes a320 EON O VMS icy i Hino 55 T SZS 90H Worqganggy mmm T onl l wilt ll lll II Iil Iil Hit Rea yur Fea 097 O E y NaIOYd woy awaya Ae D SUB9 Female PIN3 wire A PINS GND PINS wire B 54321 oao Dip Switch A Dipi Not Used Dip2 Functioning Mode Normal Mode a l E gt aan aE Fe Figure 1a Connection scheme for HD67575 A1 with c s
17. ernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 10 of 22 Connectors3 PROGIBUS port D SUB9 Female PINS wire A PINS GND PINS wire B g 54321 ETHERNET The Ethernet connection must be made using Connector3 of HD67575 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable i Connector2 i i i Ethernet port RJ45 Plug ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 11 of 22 Industrial Electronic Devices USE OF COMPOSITOR SW675 75 To configure the Gateway use the available software that runs with ADFweb com Compositor SW67575 PROFIBUS m 2 Ethemet Exemplel Windows called SW67575 It is downloadable on the site as s www adfweb com and its operation is described in this document lea This manual is referenced to the last version of the software present al New project 2 Open project on our web site The software works with MSWindows MS 2000 XP When launching the SW67575 the right window appears Fig
18. f Dip Switch A at OFF position Turn on the device HD67575 Al1 WITH C S B150 w Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode ADFweb com Srl IT31010 Mareno Treviso INFO Turn off the Device Disconnect the Ethernet cable Insert the IP 192 168 2 205 Turn on the device Connect the Ethernet cable Press the Ping button must appear Device Found Press the Next button Check the Connection the device Device Found cot neo Update Firmware from Etherne rit P Update Device Options Zil Firmware Tl Read Firmware when finish zj Project Til Read Project when finish Execute update firmware www adfweb com Phone 39 0438 30 91 31 User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 15 of 22 Industrial Electronic Devices At this point the configuration firmware on the device is correctly updated If you know the actual IP address of the device you have to use this procedure B SW67575 Ethernet Update Turn on the Device with the Ethernet cable inserted INIT OK Ver 1 001 Insert the actual IP of the Gateway Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the
19. ing The Slave informations Byte 4 gives informations about the slave interrogated Every bit has a meaning BitO Configuration corresponds Bitl Parameters OK Bit2 Configuration OK Bit3 Data OK If all is correct you have to read OxOF Example5 Request to get data from address PROFIBUS 21 without writing nothing Extended Mode Request 95 00 00 Response 03 15 00 OE BA 27 28 45 65 71 00 00 00 00 00 00 00 00 6B 04 00 00 1A 00 00 00 00 00 Ai 11 00 00 00 00 00 00 00 00 6B 04 00 00 1A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 27 28 45 65 71 00 00 00 00 00 00 00 00 6B 04 00 00 1A 00 00 00 00 00O A1 11 00 00 00 00 00 00 00 00 6B 04 00 00 1A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 36 ROM weet ete TONA aana tot ote APS lS AO Sls 1S als oe 3 el StS Sle e eae aS eS Bela 3S 10 13 13 131313135 de ie Io tests AS ti tet ae 131115313111313 1013 13 13 13 13 13 13 13 13 13 13 13 13 11 11 13 11 11 13 13 11 13 13 11 13 12 00 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL MECHANICAL DIMENSIONS ORDER CODE Order Code HD67575 A1 ACCESSORIES Order Code AC34001 Order Code AC34002 Industrial Electronic Devices
20. l F Define the parameter of the PROFIBUS Define the parameter of the Ethernet line Define the PROFIBUS network ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Revision 1 010 Page 5 of 22 Phone 39 0438 30 91 31 User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 6 of 22 AL Industrial Electronic Devices POWER SUPPLY The device can be powered between a wide range of tensions For more details see the two tables below Consumption at 24V DC Oooo owie woa A Caution Not reverse the polarity power Connectori Power Supply port OV Ground E V Positive wire V AC min 8V max 24V OV V V DC min 12V max 35V HD67575 A1 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 7 of 22 Industrial Electronic Devices FUNCTION MODES HD67575 Al1 WITH C S B153 The device has got two functions mode depending of the position of the Dip2 of Dip Switch A The first with Dip2 in Off position factory setting is used for the normal working of the device The second with Dip2 in On position is used for upload the Project Firmware Dip Switch A Dipi Not Used Dip2 Functioning Mode ver BBE Boot Mode HD67575 Al1 WITH C S B150 The device has got t
21. ow Set SEn Communication appears Fig 3 Baud rate Ethernet The window is divided in two sections one for the PROFIBUS and the other for the Ethernet EEE The means of the fields for PROFIBUS are SUBNET Mask Inthe field ID Dev the address of the PROFIBUS side is defined oo Inthe field Baud rate the baud rate for the PROFIBUS side is defined he GATEWAY The means of the fields for Ethernet are s2 jiss e e Inthe field IP ADDRESS insert the IP address Port Inthe field SUBNET Mask insert the SubNet Mask If the GATEWAY field is checked it is possible to insert in the field under the IP Address for going out to the net j Inthe field Port insert the number of the port Figure 3 Set Communication window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 13 of 22 Industrial Electronic Devices PROFIBUS NETWORK By pressing the PROFIBUS Network button from the main window for SW67575 Fig 2 the window PROFIBUS Network Fig 4 appears In this section you can add modify remove the GSD files of the PROFIBUS slaves When you select the slave by double click or by the Modify Slave PROFIBUS button the window PROFIBUS Device Fig 5 appears Inthe section ID
22. wo functions mode The first Normal Mode is used for the normal working of the device The second Boot Mode is used for upload the Project For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Ethernet Server from to PROFIBUS Master Document code MN67575_ENG Revision 1 010 Page 8 of 22 Industrial Electronic Devices LEDS The device has got five LEDs that are used to give information of the functioning status The various meanings of the LEDs are described in the table below HD67575 Al WITH C S B153 LED Normal Mode Boot Mode ON Powered ON Powered 1 Power green OFF Not powered OFF Not powered l l l Blinks quickly Boot state 2 Ethernet comm green Blinks quickly when receive Ethernet commands i l Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state 3 Device State green Blinks slowly 1Hz Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state 4 PROFIBUS comm green Blinks quickly when there is PROFIBUS communication Blinks very slowly 0 5Hz update in progress ON Ethernet cable connected ON Ethernet cable connected 5 Ethernet Link green l l OFF Ethernet cable disconnected OFF Ethernet cable disconnected
Download Pdf Manuals