Home

02070060 ES5200 User Manual

image

Contents

1. LED display as the following YY number low order of the year such as 2000 high order fixed 20 low order 00 99 can be set press ENT to edit LED display input the new number press ENT again to confirm Such as input 3 press ENT means the low order is 3 it is 2003 NON__number display the present month of the controller such as NON 11 means November press ENT to edit LED display input the new number press ENT again to confirm Such as input 3 press ENT means the month should be 3 it is March DD _ number display present date of the controller such as DD 18 means 18th press ENT to edit LED display input the new number press ENT to confirm again Such as input 16 press ENT the day is 16 it will be 16th DE _ number display the present week of the controller such as DE 5 means Frida Controller will calculate the day to display as reference HH number display the oresent Time such as HH 18 means 18 00 press ENT to edit LED display input the new number press ENT again Such as input 16 press ENT means 16 00 NIN number display the oresent Time such as HH 18 means 18 minutes press ENT to edit LED display input the new number press ENT again Such as input 16 press ENT means 16 minutes SS number display the oresent Time such as HH 18 means 18 seconds press ENT to edit
2. Size L382mmxW200mmxH71mm Color Black 6 characters digital LED display Display Color red illuminance gt 150 Lux 17pcs conductive rubber pad Color grey Pressure 100g 1000g MAX 10Kg Times more than 100 thousand times Keypad ES5200 User Manual eek 2550g 3 more or less because of the different packing DC Voltage DC12V 5 Current do not read card 30 50mA Read card drive the relay and buzzer lt 100mA Ripple wave gt 500mV 1KHz Instant absorption interference gt 2000V 600W 100uS Relay output MAX DC12V 2A 25Sec Power Drive DC24V 2A 25Sec AC75V 3A 25Sec Temperat Working O C 55 C ure Not use 20 C 70 C Working 20 90 Not use 5 95 Time Deviation lt 30 seconds per month Humidity EFT 2kV 5kHz power supply and all the input and output ports Noise of flexibility 2kV power supply and all the input and output ports ESD Immunity 6kV contact discharge 8kV air discharge all the leakage technical parts and terminals EMI Commun ication RS485 Interface User Registered user 1700 can be extended more than 10 thousand Record Records 6144 can be extended more than 10 thousand 1 4 ES5200 Functions 1 4 1 Maximum registered different users 1700 Card No of the proximity card 5 bytes User ID 4 bytes Valid date of user Jan 1 2000 to Dec 31 2099 Personal password of the user 4 bytes Types of user
3. for example OPT 20 means open delay 20 X 0 1 2 seconds Press ENT to change input new number 20 255 and then press ENT to confirm For example press ENT LED display input 100 and press ENT t the open delay is changed to 10 seconds If wrong input greater than 255 or less than 20 request input again Open delay define Legal swiping card controller is waiting for open the door do not open the door to entry at this time it will make arecord swipe card but not entry alarm record ouput the alarm or not it depends on the electic magnetic lock can close the lock when controller close it or not If it can be lock no alarm if not the door is actually open need open and close these merchanical operation using merchanical pressuer can press the spring inside the lock back to lock It is for electric impulse lock So Open delay means after swiping card in this time interval to inspect the door open or close open delay finished inspect if the door is closed dual use 2 3 5 Infared monitor IrS number From appear the infared alarm to be confirmed by the controller it is the relay time of the alarm infared alarm happens not always alarms if there is legal swiping card in the delay time it is not alarm And after the legal card is swiped controller will close the infared monitor If in the delay time there is no legal card swiped the system will make it as illegal entry monitoring
4. normal user special user VIP Limit of the allowed time interval 1 4 2 Support many kinds of way to open gt Swipe the card to open the door single car double cards gt Swipe card and user password keypad gt User ID and user password keypad gt gt VVVVVV Remote control Exit button 1 4 3 Support network Working settings of the controller edit or change User management authorize add user or cancel authorization delete user Vv ES5200 User Manual gt Data collecting story records loading gt Reald time monitoring door open or close infrared monitor status of the controller etc gt Remote control gt Communication standard under the standard of YDN023 1996 1 4 4 Time interval control 1 working days and holidays management entry time interval Working days can set 16 limited time interval list for different user every list can have 6 different limited time interval Resting days and Holidays Resting days in a week for every week can be set none any day or any two days as resting days Legal holidays can be set 40 groups For example Jan 1 May 1 etc Can set one allowed time interval list have 4 different allowed time interval 2 Managing allowed time interval by week from Monday to Sunday Can set 16 allowed time interval list for different user every list have 6 allowed time interval 3 Protection period normally open normally close intrusi
5. LED display input the new number press ENT again Such as input 16 press ENT means 16 seconds ES5200 User Manual 2 3 3 Network communication ID number display the address code 1 of the controller limits 1 254 press ENT to edit inpute the number and press ENT to confirm Such as press ENT LED display _ input 114 and press ENT it makes RS485NET address code 1 changed to 114 For example inlput wrong re input is requested grP__number display the packet address GROUP of the controller range 0 15 If the connected devices are more than 254 pcs in one RS485 system it will make the devices as 0 15 groups total 16 groups So the RS485NET address ID of the controller It is called address code in the group Press ENT to change input the number and press ENT to confirm For example press ENT LED display input new number 1 and press ENT make the RS485NET as group address code change to 1 If wrong input re input again means make the device as GROUP 1 CID1 114 means addess code in group is 114 BAUD number speed between the controller and the system 0 means 4800BPS 1 means9600BPS 2 means 19200BPS 3 means 2400BPS Using RS485 as the communicate between controller and the system maximum distance is 1000m in one net line can connect 32 controllers at the most but do not advice to do that because once the net line was cut by the accident or the drive of the controller have some problem
6. by the sunshine 4 Avoid the controller to get wet by rain 5 Before the installation must check the wireless jumping take correct of the controller 4 1 Preparation before the installation Before install the ES5200 controller must investigate and know the environment of installing and using Even the service time of the controller is set long time but the controller can not be used in the following environment for long tim maybe affect the service time Shining under the sunlight for long time Working under high temperature and humidity environment Working under sault fog environment for long time Working under the acid gas or other corrosive gas environment for long time So when install the device avoid intalling them in above environment if must install in that area do some protection for the devices 4 2 Controller installation Even the service time of ES5200 is set very long but any electric device can not work forever maybe out of use any time The controller itself make some design to make it install and repair expediently when install the controller also need to think about maintainance and repairment in the future to be convenience Installation steps Picture 4 2 22 ES5200 User Manual 330 HANK MRE ARENT Picture 4 2 ES5200 installation map Installtion steps 1 use the key to open metal box of the controller 2 install the metal box in the selec
7. circuit with GND or the other signal wireless 5 4 card is registered the authorization by the software why still display ERR 08 when swipe card Swipe card and display ERRO8 means can not find this card in the controller The controller can save the Card No only but there are many ways to get the Card No For different user have different requests different developers also have different handlings so one card using different ways get different Card No Through the software to get card No when register the authorization depends on software handling and card issuer For example card No is 04 B5 13 A2 09 The controller has its own handling when swipe card to get the card No if the handling 5 is the same as the software uses it can get the same Card No 04 B5 13 A2 09 if they are different it will get different Card No such as 00 00 13 A2 09 So must make the handling methods be the same setting 5 5 what is confirm time delay of the invasion detection infared sensor When ES5200 has connected with invasion detection sensor and open the invasion detection functions once the controller receive invasion signal start timekeeping immediately and detect if it has swiped legal card time should be the Ir S ruling time for details Chapter 2 3 5 If it swipes legal card in the time controller willl judge it as registered authorization people entry no alarm if it does not swipe legal card in the time
8. it will make troubles of all the devices normal user and it is also not easy to make the maintaince Here propose to use concentrator to do the project It make one net line as 4 separate branch lines the branch line can connect 32 devices at the most Even one branch have problems the other branch lines also can work well ES5200 use RS485 for the communication can support the verifications are as follows SPACE verification MASK verification ODD verification EVENverification NO verification Default support 1start bit 8 data bit 1 stop bit no verification bit S O E number verification methods of RS485 network communication 0 no verification 1ODD 2 evenparity verification 3 MARK 1 verification 4 SPACE 0 verification default 0 1start bit 8 data bit 1 stop bit no verification ES5200 User Manual 2 3 4 Controller parameters rLY__number means the operating time of the relay get the signal to open the door unit 0 1 second for example RLY 30 means 3 seconds If the electic magnetic lock is power up door open close power off will open close the door automatically so RLY delay and OPT delay are the same if the electric magnetic lock is power up door open close power off can not automatically open close the door so RLY delay and OPT delay are different Maybe RLY delay 0 2 seconds but OPT delay 2 seconds OPT number means OPEN DELAY unit 0 1 seconds
9. lock is usual closed power off close actually Please check the following sheet JMP2 kinetic energy definition 18 ES5200 User Manual JMP2 usual open usual close settings define 1 2 short circuit usual close lock ei Wai r HEB JMP2 2 3 short circuit a usual open lock power off lock 3 Picture3 3 1 extend usual open lock JMP2 must be 2 3 broke up status For example extend usual closed lock JMP2 must be 1 2 borke up status 3 3 2 ES5200 extend double lock i ia ee ups es es 5 LOCK a eeoa Picture 3 3 2 ES5200 extend double lock Remark 1 Above two methods of extend single lock are the same as the internal port optional 2 ES5200 extend double lock JMP3 jumping take must set it as 1 2 short circuit Picture 3 3 2 JMP3 defines check Chapter 3 3 1 3 Picture 3 3 2 extend usual open lock JMP2 must be 2 3 broke up status If extend usual closed lock JMP2 must be 1 2 broke up status 4 Extend double lock use RJ45 LOCK to extend double lock because of the defines of the RJ 45 change over panel inside connection door switch of the lock must set it closed door open the principle is as picture 3 3 2 1 19 ES5200 User Manual 4 C 3 NO 3 NO 4 C 4 C Q O ES5200 fT TRAHI BAT JRAH2 3 NO Picture 3 3 2 1 Connection principle of the double lock door switch Both ends of the door swit
10. 1 Allow input ID and Password to open the door personally Remind linkage input CPINS the effective electric level is fixed by the controller as low electrical level 0 5V 0 3V or touch point input means short circuit C3 number working method of the controller control second byte default 0 Caculate it as follows One byte D7 D0 D7 high bit defines as follows BIT Control defines 1 using usual closed time interval in the set closed time D7 0 1 usually close the door 0 1 using usual open time interval in the set open time open pe 1 the door except holidays and rest days D5 0 1 0 inspect the allowed time interval of the allowed people 1 do not inspect D4 oA 0 inspect the valid authorized date of the allowed people 1 do not inspect D3 0 1 1 open intimidation alarm function 0 close D2 0 1 1 time interval for right swiping card and personal password open i Fission swipe card head right swiping card and must D1 input personal password 0 Fission swipe card head right swiping card a Subject swipe card head after right swiping card must DO input personal password 0 Subject swipe card head swipe card right will be ok 2 4 Add card or delete card on the keypad Afte r the password confirmation press F3 start add or delete card operation LED will display as follows ADD CD add card Press ENT to start display ID requests to input
11. CAN SET If wrong input LED display PIN ERR can input again but only three times if all the three times are woring LED remind HALT must wait for a few while and then can input again by the keypad Afer the password confirmation controller can load the keypad settings If the interval more than 8 seconds and no operation the controller will automatically close the allowed setting authorization Next time to make settings must confirm the password again 2 3 1 Controller settings password edit Press F1 to edit the settings password After LED display CHG PIN and need to input the new password it will remind input the six numbers of password and ENT to confirm LED will remind second times confirmation AGAIN it will display input the six numbers again the numbers must be the same to be valid ES5200 make the new password as the keypad password Attention keypad settings passord is the part of the systempassword of the controller 5 bytes software aggravating password 2 bytes ES5200 User Manual keypad settings password 3 bytes So using keypad to change keypad settings password must change the device system password which is saved inside the software database in the computer 2 3 2 Date and Time settings After the password confirmation controller load the keypad settings press F2 to display or edit the control parameters
12. ES5200 User Manual Contents 1 ES5200 Access Controller brief introduction 000 0000000 3 V1 SUMMAniZO a a heat a a a cto es latest e cee hts oe 3 1 2 SWUCTULE diaga Miseni Medes eedhvteel aiden hide deste 3 1 3 ES5200 Parameters snie aei ke ere rai 3 1 4 ES5200 Functions ccccccccccessneceeeeneeeeceneeeeeceaeeeeseeeeesenseeeesseeeeeas 4 1 5 ES5200 Packing list 2 che a e ide a e a a 6 2 ES5200 Keypad operation nuncnniennicninenkenuainnmnnenunennd 6 22 Eror prompt osina an a a a E A E E REA AE A NEA 6 2 2 keypad ihstr ctUons cars uar a RAE EESE at Mate innate ITET 7 2 3 system settings 2 3 1 Edit password of the controller gt il 451 E EIB 7 2 3 2 Date and Time SettingS eeccceeeeseeeseneeeseneeeeeeeeeeeeneeeeeaeeeeenaeeseeeeeteaees 8 2 3 3 network communication 9 2 3 4 Controller Parameters 10 2 3 5 infared monitor 10 2 3 6 control byte 2 4 add delete card by keypad 2 5 open infare by the keypad 14 2 6 open door and edit password by the keypad 14 2 7 secondary encrypt ou eee 15 2 8 reset controller password 15 3 ES5200 connection defines sisisi caiiiiisaniiini aen iaanuni soian cuaine auei inei Seaca 16 3 1 RJ45 change over panel functions instructions eeseeeeeeeeeeeeeeeeeeneeeeeeees 16 3 2 ES5200 RS485 communication 3 3 ES5200 extend electrical control lockl 3 3 1 ES5200 extend single lock 00 0 e ce eeeeeseeeseeesee
13. aessessseesseanseneeeeeaea 3 3 2 ES5200 extend double lOck eceeeseeeeeeeeeeeeneeeeeeeeeeeeeseeneeeeeneeeseaee 3 4 ES5200 extend card reader 3 5 ES5200 extend infare eeeceeeeeseeeeeteeeeeneeeees 3 6 ES5200 extend exit button and emergency input 0 eee eee eens 21 4 INStAllAtiON INStUCTIONS a enian oa Note ness deen deve sdauocc ta eva ane sence aai Aaaa aAa 22 4 1 preparation before installation 4 2 installation of the controller common problems and questions 0 cc ieee ee eee cesta 5 1 why using RS485 to be network but can not communicate 5 2 how to extend the communication distance for RS485 422 5 3 why display ERR 00 when swipe Card ue ee eee cece eee c eect ee teae seas eee eneeeeee 24 5 4 card is registered the authorization by the software why still display ERR 08 when SWIDG Card on c ct Ac et saa a Mele ean il on ah ee a 24 5 5 what is confirm time delay of the invasion detection infared sensor 24 5 6 how to close Door Status alarm ccccccsescescesessecesseecseeeeseeesaeseeseeeeaeseseeseneeees 24 5 7 how to close Infare alarem ccesccceeseeeeeeneeeeeeeeeeneeeeeaeeeseaeeeseaeeseeaeeeseneeeees 25 5 8 Closed the infared alarm after swipe legal card why after the delay time alarm again Pit cn see cee Pete are de Aca alte Mav nck ie cunts meat cre eared tater we Mera tentde 25 5 9 Why press the Exit Button but no response ceceeeeeeeeeeneeeeene
14. area to make alarm Unit 0 1 seconds For example IrS 50 means 5seconds means the time from the legal user entry the monitoring area until swipe the card on the reader IrT number allowed registered people using ES5200 keypad to open the 10 ES5200 User Manual infared sensor monitoring controller will have a delay time to let the authorizated people to leave in case it illegal entry the monitoring area to have alarm Unit 0 1 seconds for example IrT 50 means 5 seconds meaning legal people open the infared monitor through the keypad depaly 5 seconds to let him leave AL d number effective drive tim of the alarm OC output At the alarm when OC output break over or disconnect the settings are made D3 bit in ral the sheet C2 second control byte check Chapter 2 3 7 AL D valid nge 0 255 valid time 0 1 25 5 AL D 0 stop the alarm output 2 3 6 Control word C1 number working method of the controller control the first byte default 0 The calculate way as follows one byte D7 D0 D7 high bit defines as follow BIT contro Defines 0 Do not monitor the door open or close status Monitor the door open or close through door switch unusual alarm D7 1 unusual open the door 1 2 lock which can not close door automatically swipe card and then close the door merchanical operation 3 after open delay finish door still not close 0 No
15. cally whatever the above D7 0 or D7 1 On the basis of the settings of D3 number detect if the door is open illegally in the Protection Time Interval so it must make correct settings of D3 If do not install door switch cut the door switch signal wireless of the controller and use the eltectrical tape to be surrounded set D7 0 and D3 0 5 7 how to close Infare alarem Most of the time the reason is that do not install Infared Device and make correct settings of the infared device in the controller For detaisl please check Chapter 2 3 6 Two bytes manage infare D6 0 whatever the detector is on or off do not detect no alarm If D6 1 must make correct settings of D2 as 0 or 1 Must know the character input of the infared detector and can make the correct numbers of D2 and no mistake alarm Reminds change it from the software and then give the commands through RS485 RS422 both chaging the device settings and change the database of the software If change the device settings only but do not change the data information in the software it will make wrong settings by the software next time Infared monitor has a Protection Time Interval if it is open it will automatically detect the infare whatever the above D6 0 or D6 1 On the basis of correct numbers of D2 detect if it has illegal invasion in the Protection Time Interval so must make correct settings of D2 If do not install infared device cut the infare signal wireless o
16. ch 4 C and 3 NO are closed when the door is closed when 3 4 ES5200 extend card reader imei poe CHD601S tH RUAS TCPIP RU45 IRID TCPIPM ORR 735 pe Rie He MSS INPI sng gees Eeim es ss mss RJ45 RS485 RJ45 LOCK RJ45 READER B ee Li CHD601S H the door is open it will be broke up iD T Picture 3 4 ES5200 extend card reader 20 ES5200 User Manual 3 5 ES5200 extend infare HON NC COM NO GND 1 Tr RJ45 TCPAP TCPIPRURH 753 T B Rie He SSI memes eee y ure RJ45 R5485 RU45 LOCK RV45 READER Picture 3 5 ES5200 extend infared input 3 6 ES5200 extend exit button and emergency input NC COM NO GND 12 HOIN GNO MOIN GND 4C 3NO 2 11 aran Pointy tn AtA MaRS RJ45 TCP IP RJ45 IR ID TCPIPRORH 733 123 i23 ree meam JMP3 ee me6 JMP2 HARARE RJ45 RS485 RJ45 LOCK RJ45 READER EJA KRHA F RERA AMS CHIP pEi e 0 KEMA P EWA AT Pa CHIP Picture 3 6 ES5200 extend exit button input 21 ES5200 User Manual 4 Installation instructions Attention 1 It must think about the maintainance and repairment for the future to be convenience when install the controller 2 Do not install the controller in the area that maybe high temperature and high humidity for a long time 3 Avoid the controller to be shining directly
17. controller will judge it as illegal people invasion make illegal invasion alarm record inside and ALARM of the controller make signal of alarm Invasion detection infare strike delay When the authorized legal people leave the limited area and try to start the invasion detection monitoring functions of ES5200 delay time is from giving signal to ES5200 by the keypad press F4 details as Chapter 2 5 until ES5200 start the functions actually in case the authorizated people have enough time to leave the monitored area no mistake alarms 5 6 how to close Door Status alarm Most of the time the readson maybe do not install door switch and do not make correct 24 ES5200 User Manual settings about the Door Switch for the controller For the details check Chapter 2 3 6 If two bytes manage the door switch D7 0 whatever door is open or closed it will notdetect and no alarms If D7 1 must set D3 0 or D3 1 correctly Must know the character output of the door ii switch and make the correct settings of D3 and no mistake alarms Reminds change it from the software and then give the commands through RS485 RS422 both chaging the device settings and change the database of the software If change the device settings only but do not change the data information in the software it will make wrong settings by the software next time Door switch motor also have a Protection Time Interval if open it will detect the door switch automati
18. ed it will have ERR 02 all the time Must set the D5 of the first byte C1 in the controller 1 install impulse anode electrical lock and install door switch can set D5 1 must set D3 byte as the charater of door switch 2 other situation D5 0 27
19. eeeeeeeeeeeneeeeeneeeees 26 ES5200 User Manual 5 10 Why display HALT swiping the Card eeesceeseeeeeeeeneeeeeeeeeeeeeeeeeeeeseneeeeeneeeees 26 5 11 Why mistake door open happened uo ee ee cee cee ece cee eee setae seas eeeeteeeeee 26 5 12 Why the controller make voice Beep frequently eee e eee eee eee eee 27 5 13 Why display ERR 02 and can not delete 0 0 eee cece eee e cee eeee teen eee 27 ES5200 User Manual 1 ES5200 Access Controller brief introduction 1 1 Summarize ES5200 include ES5200 host controller RJ45 connection change over panel DC12V 3A power supply Good installation wireless connection and wiring look With the special security of proximity intelligent card electric lock infrared sensor and network communication it makes safety and intelligent In Out controlling system which also have network connected security and monitor functions It is widely used in Bank Access Control and Smart residential area etc 1 2 Structure Diagram ES5200 is installed inside a metal box all the extend wireless are connected with the RJ45 change over panel and change to network wireless through the bottom to connect with the outside As Figure 1 1 having power supply and the function settings are set already for the device parameter settings it will be better to make settings by the software easy to operate and manage Figure 1 1 Structure Diagram 1 3 ES5200 Function parameters Parameters
20. el functions instructions ES5200 make the connection easier through RJ45 change over panel as Picture 3 1 HDIN GND MDIN GND 4C 3 NO 2 1 4 N C COM N O GND 12V HT BEER MES oR mh MEH AT LR RU45 TCP IP RJ45 IR ID TCPIPHOHH 735 123 123 niedi fe meemi ips wes se uue2 RJ45 RS485 RJ45 LOCK RJ45 READER Picture 3 1 RJ45 Change over connection defines 1 RJ45 RS485 defines 2 RJ45 LOCK defines No Sign Wireless 1 Orange white 2 orange 3 Green white No Wireless 4 GND blue 1 Orange white 5 GND Blue white 2 orange 6 green 3 Green white 7 485A Brown white 4 Blue 8 485 B brown 5 Blue white 6 Green Door switch Brown 7 white 8 GND brown 16 ES5200 User Manual 3 RJ45 READER defines 4 RJ45 IR ID defeinse infared interface No Sign Wireless 7 WDO Orange Sign Wireless white 12V Orange 2 WD1 Orange white 3 Green white arange 4 GND Blue white 5 12V Blue white GND Blue 6 Green GND Blue white 7 Brown white Green 8 Brown Brown white 5 terminal blocks defines IRID Brown No Sign Wireless Wireless 1 HDIN Exit button anode yellow 8 1 Electric control lock o o oo o ooo anode red 2 GND Exit buttone cathode black 9 N C Alarm output obligate 3 MDIN Fire linkage anode orange 10 COM 4 GND Fire linkage cathode black 11 N O 5 4 Lock public terminal white 12 GND Power supply input o O o cathode black 6 3 NO Lock door switch usual open 13 12V Power supplyinput te
21. f the controller use the electrical tape to be surrounded set D6 0 and D2 0 5 8 Closed the infared alarm after swipe legal card why after the delay time alarm again After swipe legal card inside the limited area the infared monitor close automatically but after the delay time open again the reason should be 1 software run well infared monitor start again through the network operation 2 If the reason is not software network operation the reason should be the current time is in the Protection Time Interval detect the infare automatically whatever the above D6 0 or 1 on the basis of the numbers of D2 detect if it has illegal invasion in the Protection Time Interval So must make the correct settings 23 ES5200 User Manual A opening method of the infare B rationality of the Protection Time Interval 5 9 Why press the Exit Button but no response Reasons should be as follows 1 connection of the button is not well 2 D4 byte of the First Control Byte details as Chapter 2 3 6 C1 one byte is set by 1 close the Exit Button Door Open function If it is not the aboved two reasons it should the problem of the controller please go the specified maintaince point or express it to the manufacture to repair 5 10 Why display HALT swiping the card When the controller is under Usual Closed Protection not allowed swipe card swipe card and password to open the door etc Display HALT means not availab
22. gain Press ENT to confirm to start the monitor controller will make a delay for details please check Chapter 2 3 6 to wait for the people leave the limited area Using keypad can open the monitor only can not close only the legal swiping card can close the monitor 2 6 Password open the door and personal password edit by the keypad Press F5 LED display ID inquires to input User ID If the controller does not have this user LED display NO USER Input the User ID four numbers correctly and press ENT then inquires to input PIN For example 1 2 3 4 and press ENT If the PIN is correct controller open the door if not LED display PIN 14 ES5200 User Manual ERR LED display PASS press F5 LED display CHG PIN and press ENT to confirm LED display PIN inquires to input the new personal password four numbers can not be 0000 ENT to confirm then LED display AGAIN inquires to repeat input the new password again the password should be the same and then the controller will save the new password and delete the old password Four number are all 0 of the password here make it special it must using the software to make the setting People who hold the 0000 as the password when they use swipe card and password methong do open the door no need to input the password This is just for some special people to be their password 2 7 second encrypt After swiping card correctly LED dis
23. ipe card must confirm password and then open the door 0 Do not allow using keypad press ENT only to open the door manually Do zi Allow using keypad to press ENT to open the door manually no more EXIT BUTTON For example open door switch monitor D7 1 128 Do not use infared monitor D6 0 Lock can not be locked automatically D5 1 32 Allow to use open door manually D4 0 Door switch open circuit when door open D3 1 8 Password second confirmation Di 1 2 not allowed to press ENT to open door DO 0 Plus all 128 32 8 2 170 input 170 by the keypad and present to confirm C2 number working method of the controller control the second byte default 0 Calculate it as follows one byte D7 D0 D7 high bit define as follows BIT control defines D7 Linkage input CPIN1 effective electrical level 0 D6 Linkage input CPIN2 effective electrical level D5 linkage CPLD1 CPLD2 input controller will give D4 response the ruled operations D3 0 1 ALARM output connect 0 when it alarms open circuit 1 D2 1 Swipe card and send the Wiegand signal to the computer which is connected by RS485 0 forbidden bj emergency event input MDIN and GND close close D1 the door Any card no response 0 emergency event input MDIN and GND closed always open Personal input ID and password to open the door DO 0 i forbidden 12 ES5200 User Manual
24. le Usual Closed Protection have two types 1 depends on the Usual Closed Time Interval in the Usual Closed Time Interval controller will usually closed swiping card is not available Set the Usual Closed Time Interval by the software for example 20 00 23 59 00 00 7 00 2 Temporary Closed Protection it is also set by the software the maximum time from the command start until end the protection is 4 hours Please check 1 Usual Closed Time Interval is set to be open 2 maybe set as Usual Closed by mistake operation Please check Chapter 2 3 6 the instructions of C3 control byte 5 11 Why mistake door open happened Reasons are 1 Wrong connection of the Exit Button wireless or the extended wireless is too long chafage wrong connected of the electric wireless 2 MDIN signal GND of the Fire Linkage selection is not good Fire Host have two contacts of the switch at the fire alarm output contact 1 should connect with GND of the power supply for the controller contact 2 connect with MDIN Fire Linkage is start by the fire host must connect with the fire host output contacts correctly If the selection of MDIN signal reference groud for Fire Linkage is wrong it will make the MDIN signal electrical level wrong for the controller It is not a stable open contacts input because of the low MDIN signal make the input optocoupler open be accepted by the controller 26 ES5200 User Manual Attention When the con
25. on detection switch monitor second times password confirmation 1 4 5 Keypad operation standalone only gt System control parameters settings time clock timing gt Add user gt Delet user gt Open infrared monitor gt User ID and password to open 1 4 6 Environment monitor and event management Door open or close monitor install the door switch Monitor the detector such as IR ID monitor or connect with smoke sensor Swipe card legal or illegal records Controller parameters are changed Allowed in user settings are changed Support linkage operation functions 1 4 7 Support many various electrical magnetic locks gt Normally open normally close gt Relay drive time 0 1 seconds to 25 seconds finish settings gt Open relay of waiting for in 2 seconds to 25 seconds finish setting 1 4 8 Record details All the events will real time making record maximum records are 6144 records VVVVVV 1 Door open records gt Records of swiping card to open the door gt Records of using User ID and password to open the door gt Records of manually push button to open the door gt Records of using RS485 remote control 2 Monitoring records gt Records of chaging working parameters of the controller gt Records of open and close the infare monitor gt Records of registered user swipe card but do not go in or go in but do not close the door on time gt Invalid swiping card unregistered card tr
26. play PIN input the password on the card reader and then open the door controller will wait the user for 5 seconds to input the password and then ENT to confirm If input the wrong number LED display PIN ERR inquires to input again if wrong input three times controller will not allow to input again If the user forget its password must use the system management software to get the user information the user password is one of the contents of the user information Or delete this user from the controller and issue again after issued 1 2 3 4 is as the default password user can change it themselves 2 8 Reset the controller password If forget the controller password not different with the personal password can not go inside the system to set Software database broke up lost the device password can not make the communicate between the device and the software Doing the settings as follows 1 Power off the controller 2 Opent he controller short circuit the inside password reset jump take RST 3 Power on wait for the controller to display the time 4 Power off push aside RST short sub jump take and install the controller again 5 Power on again all the numbers of the system password 5 bytes will be 0 Means software aggravating password 2 bytes will be 0 0 Keypad set password 3 bytes will all be 0 15 ES5200 User Manual 3 ES5200 connection defines 3 1 RJ45 change over pan
27. rminal white Cano e red 7 2 Electric control lock cathode black 3 2 ES5200 RS485 communication ES5200 use RS485 communication interface inquires the devices hand in hand chain connection methods Such as Picture 3 2 ES5200 1 OT Ra Rea ais 6 amp 9 oe oe om pE M i ES5200 4N Efi Picture 3 2 ES5200 RS485 communication connection 17 ES5200 User Manual Remark RS485 inquires the devices to be connected hand in hand chain connection ways the terminals must connect with 120Q terminal resistance RJ45 change over panel provide 1200 terminal resistance as incoming end as Picture 3 1 JMP1 JMP1 485 receiving end resistance defines 1 2 short circuit JMP1 2 3 short circuit 3 3 ES5200 extened electric control lock 3 3 1 ES5200 extened single lock RAPID RUAS TCPIP TCPIPRORH 735 Rie Eeee ips wes Mem RU45 RS485 RJ45 LOCK Picture 3 3 1 ES5200 extend single lock Remark 1 aboved two kinds of extending single lock its internal port is the same select one is ok 2 ES5200 extend single lock JMP3 jumping take must be set as 2 3 short circuit Picture 3 3 1 JMP3 make defines as follows JM3 single lock double lock settings defines 1 2 short circuit Connect double locks JMP3 2 3 short circuit Connect single lock As picture 3 3 1 when the lock that ES5200 extended is usual open power off lock open if the
28. s 0145 1 0146 repeat the same operation Press ESC to quit If the user id that the controller made is exist in the controller already controller requests to input the user id again to start Attention Doing the keypad operation on the controller can not issue the personal password of the user or change the password to be 0 make the settings on the computer throught the software only DEL CD Delet card After press ENT LED display CARD swipe the cads that plan to delete one by one if the card which is planning to delete is not exist in the controller it will display NO CD means no card need to delete and the corresponded user is also canceled means cancel the authorization DEL ID Delete user After press ENT LED display ID inquires to input the user ID that want to delete For example 0145 press ENT means delete the user which ID is 0145 and its corresponed card authorization is also canceled DEL ALL Delete all Press ENT at the first time LED display AGAIN ask for second ENT to confirm and then make all the entry and exit records be cleaned If do not press ENT to confirm can not do the Delete operation 2 5 Open the infare on the keypad Press F4 LED display r ON press ENT to confirm means open the infared monitor The controller will close the area infared monitor after the legal swiping card to entry the limited area If all the people leave need to open the monitor by the keypad a
29. status monitor functions of the door ERR 02 Right swiping card controller open the door relay but no merchanical operation pulse electic magnetic lock ERR 03 Infared alarm after open the infared monitoring function of the controller please transfer Chapter 7 ERR 08 unregistered card swipe ES5200 User Manual ERR 09 out of date of the registered card can not entry the previous authorized allowed area ERR 10 regisgered user try to entry the protected area at thenot allowed entry time interval when the controller is under the allowed time interval monitoring ERR 11 swipe card and password entry management right swiping card user input wrong password three times no authorization to entry when remind HALT must wait around 2 minutes to retry again 2 2 Keypad instructions Number keypad 0 1 2 3 4 5 6 7 8 9 for inputing the numbers Function keypad F1 F2 F3 F4 F5 ESC ENT for functions operation F1 entry functions setting change password F2 parameter setting of the entry controller F3 entry user management F4 invasion sensor protection by keypad F5 input user ID and password to open the door ESC exit setting ENT confirm input or setting 2 3 System settings Enter the system and make settings must have keypad setting confirmation of the password press F1 LED display PIN input 6 numbers as keypad setting password If correct input LED display
30. t use infared monitor Infared monitor illegal entry the monitoring area and alarm make records Legal swiping card to entry or input user ID or password to D6 P entry on the KEYPAD RS485 remote control to open entry controller will automatically close infared monitor Using RS485 remote control to open or using KEYPAD to open directly using KEYPAD can not close open only legal swiping card only can close 0 Electric magnetic lock close automatically after power off or power up D5 2i Must be open and then close using elastic force of the merchanical operation to be closed D4 T Can use open manually short circuit signal wireless and GND wireless to open the door 1 forbidden Set the door switch output level as 0 Door open the two signal wireless is short circuit connect door close D3 two wireless are open block up Set the door switch output level as 1 Door open the two signal wireless is blocked up open door close two wireless is short circuit connect 11 ES5200 User Manual Set the output level of the infared detector short circuit connect as alarm as usual no alarm two signal wireless is short circuit block up ve Set the output level of the infared detector alarms signal wireless short a circuit block up normally no alarm signal short circuit disconnect 0 Legal swipe card can open the door no more confirm password D1 again 1 Sw
31. ted area that want to install 3 make all the outside wireless import from the two round holes at the bottom of the metal box 4 connect all the wireless with the controller details as Chapter 3 1 connection defines 5 check all the connection test all can work well 6 close the cover of the metal box and lock 5 Common problems and question 5 1 why using RS485 to be network but can not communicate The reasons that maybe make the communication failed 1 device ID repetitive chand ID and GRP number details as Chapter 2 3 3 all the device ID can not be the same when login the devices in the software database network device ID installed can not be repetitive either make settings by the device keypad 2 communication wireless A and B reversed connect them correctly 3 signal communication wireless GND did not connect sometimes connected sometimes disconnected and lose data connect the DND is OK 4 both ends of the communication speed are different or both ends of the verification method are different 23 ES5200 User Manual 5 2 how to extend the communication distance for RS485 422 Extend the communication distance for RS485 RS422 must use the signal enhancement devices such as HD485HUB CHD422HUB etc 5 3 why display ERR 00 when swipe card Signal output of the reader WDO WD1 reversed when connect with the controller interconvert WDO and WD1 is ok Or one of the signal wireless in WDO and WD1 short
32. the User ID No which will hold the card for the details check Appendix 2 in the system every user have one User ID and one card if lost the card can cancel its authorization and issue a new one the User ID no need to change User Id is comprised by four number such as input 0145 and press ENT means ID No of the new user is 0145 If the ID No is exist in the controller already LED will display HAS IT and request to input again LED display UD means to input the authorization valid date of the user from the beginning issue the card to the end of the card authorization For example 13 ES5200 User Manual expired date is May 23 2004 input 040523 and press ENT If press ENT directly means the expired date is Dec 31 2099 it is always valid After input the valid date LED will display CARD means Please swipe card the controller will automatically set this card as Allowed Entry Card If the Card No is exist in the controller already LED will display HAS IT it is not allowed that one card for different user by the controller If want to change a new card swipe the card again Controller will automatically give the new user a default password PIN 1 2 3 4 the user can set its PIN itself check the details as follow Controller add 1 for the user id automatically to the new card If the new user id is not exist in the controller display CARD then swipe the next card again and its corresponded user id a
33. troller distinguish Exit Button and Fire Linkage will make identify treatment for the signal width 200 milliseconds The inteferrence pulse is less than 200ms it will have no response by the controller 5 12 Why the controller make voice Beep frequently Because the voltage of the power supply is not enough or the power can not support enough current make the controller can not start reset frequently voice again and again controller display the Model No 5 13 Why display ERR 02 and can not delete Such as pulse anode electric lock after power up the spring bolt will retract the lock body after power off spring bolt can not strech out automatically If can not strech out means can not close the lock and the door is open need the merchanical open door and close door operation the merchanical operation pressure can retract the sping inside the lock body let the spring bolt strech out and locked it is specially used on electrical impulses lock ERR 02 means spring bolt retract but can not lock the door automatically to be the alarm When using impulse anode electrical lock it is power up and open the lock when swipe the card must open the door and close it if not the door will always be OPEN status because the spring bolt is retractile To judge the door open or close must install door switch If install the impulse anode electronical lock but do not install the door switch controller can not judge the door open or clos
34. y to swipe card and go in ES5200 User Manual gt Invalid authorization out of valid date or unauthorization of the limited time interval try to go in 3 Alarm records gt Infared sensor alarm illegal entry gt Door is open unnormally illegal entry 1 4 9 Alarm Output gt ES5200 support OC door alarm output and can set the output status in alarms 1 4 10 6 characters LED digital display Real time display Keypad operation remind Swiping card operation remind Alarm codes remind VVVV 1 5 ES5200 Packing List White box barcode tag outside ES5200 1pcs Model tag and Date of manufactured Fixed gel column tapping screw abatch AC220V power plug wire 1pcs User Manual include Wireless connection and installation map Guaranty card and Certification 2 ES5200 Keypad operation introductions ES5200 have various keypad operation system time setting controller working parameters setting register card or delete by keypad password open and Infare anti intrustion protection etc 2 1 ERROR prompt ERR 00 Card No inspection error If the controller receive the Card No that is read by the reader does not follow the ruled data format controller will show ERR 00 Reason for this error is the data maybe interfered at the data transportation or wrong connection of WDO and WD1 ERR 01 after swiping card but do not close the door after open the Open Close

Download Pdf Manuals

image

Related Search

Related Contents

  Portail Imagerie médicale des cliniques Saint Jean Mode d`emploi  Accu-Chek Mobile  Oreck XL20R7RH User's Manual  Guide d`utilisation ST70  ONAG user manual - Innovations Foresight    DPF-742 SPANISH manual    Delta Electronics DVPDT02-H2 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file