VMB4RYLD
Contents
1. VMB4RYLD Programmable 4 channel voltage out relay module for Velbus system A On DESCRIPTION ii iii 3 CHARACTERISTICS nnen neneneenennenenensenenennenennanenensenenensenenensenenensanenennenenennse 3 VELBUS CHARACTERISTICS osrstenie ila eE E AE aE E aE aE REN ADAE APONEA 5 ENNEN 6 EED INDICA HONS oaren eea EEE NEEE nidi ariana aan 7 LOCAL GONTROL TTT 8 51 i 9 Mains Voltage Connection Diagram i 9 Low Voltage Connection Diagram ee 11 JEE EIERE 12 CORNOUFAO i a ee 13 En 13 Se GOI AC DEAVIO D ee 13 OT Ol ICONS senen nnee 13 CHECKING THE SOFTWARE VERSION 17 2 VMB4RYLD 4 channel relay module user manual version 1 DESCRIPTION This relay module is suited for switching on or off the lighting in the living room the garden fountain the mains outlets in the children s room and many more In order to limit the wiring in the switchboard cabinet this module features a mains voltage input and four voltage outputs to which the consumer can be connected directly This is only suited for use in a Velbus system Multiple functions e g switching on off timers are to be programmed via the Velbuslink software CHARACTERISTICS Use e suitable for switching on off mains powered lighting or consumers e connection of a low voltage e g 12V instead of a high mains voltage to the voltage input allows the switching of up to 4 low voltage consumers e g 12V light bulbs
2. are switched on again All appliances get intelligent how about your home Choosing for Velbus means choosing for a future proof system which provides comfort safety and a better energy management at a price which is just slightly higher than classical wiring A sudden noise wakes you up in the middle of the night Press your bedside button and your home comes alive All lighting is turned on while all blinds open The garden lighting starts to flash to attract attention Velbusmodules on Velleman website Velleman Forum ENERGYSAVING Zi I a Bedtime Again you press a single button All lighting is turned off and nightlights start to glow The garden remains lit for an hour Wall outlets are turned off again for safety and to reduce electrosmog Finally the heating is lowered with a couple of degrees Refer to our website for more information www velbus be VMB4RYLD 4 channel relay module user manual version 1
3. switch off LEDs on a control module switch on LEDs on a control module slow or fast blinking of the LEDs on a control module The relay module can receive following messages pushbutton module status The relay module can receive following commands switch on relay channel switch off relay channel start timer start blinking timer recall relay status recall module type and software version recall communication error counter recall relay names recall memory contents overwrite memory contents switch off pushbutton indication LED VMB4RYLD 4 channel relay module user manual version 1 OVERVIEW ar SIN rar STN C LOAD1 LOAD2 LOAD3 LOAD4 4 Ch relay module VMB4RYLD 2D 90000000 SUPPLY BUS L IN N Connections consumer output channel 1 power LED consumer output channel 2 Velbus RX receive LED consumer output channel 3 d Velbus TX transmit LED consumer output channel 4 consumer output voltage Velbus Velbus power supply 6 VMB4RYLD 4 channel relay module user manual version 1 LED INDICATIONS TI STIN T2r STIN TI STIN T4r STIN C CCC CC C C LOAD1 LOAD2 LOAD3 LOAD4 4 Ch relay module VMB4RYLD 7 00000000 L NN VMB4RYLD 4 channel relay module user manual version 1 7 LOCAL CONTROL Remove the cover Tar STIN TA STIN LOAD1 LOAD2 LOAD3 LOAD4 1 2 Rx Tx TERM PS DV QO O OO CO OC S
4. e only suitable for use in a Velbus installation Outputs e 4 voltage outputs with common N connection e single pole NO relay contact e relay contact debounce e switching capacity o 16A 230VAC input voltage o 12A 30VDC input voltage o allowed switch on current up to 80A lamp switch on current e Total allowed consumption of the 4 channels o 16A 230VAC o 12A 30VDC each relay channel may be inverted in order to simulate an NC contact e 1 extra virtual channel LED indications e status indication for all 4 channels o continuously lit relay switched on o Slow blinking timer 1 running o fast blinking timer 2 running o two short blinks communication error e power voltage present e data reception and transfer over the Velbus e status notification of the relay channels to the control modules Module power supply e required power voltage 12 18VDC e consumption in stand by 30mA e max consumption 250mA Dimensions e standard DIN rail housing 4 modules e LxWxH 90 x 71 x 58mm Configuration e only configurable via the Velbus PC interface VMB1USB VMB1RS or VMBRSUSB and the Velbuslink software addressing through software up to 250 addresses storage space for 39 different pushbuttons and their function multiple functions and timer settings are configurable through software learned pushbuttons are saved in case of a power failure Control e local on off control on the module e no direct pushbutton connecti
5. removed Je lt lt Le KE Remark In case of a wiring with multiple branches only place a termination into a single module in the distribution box and in the control panel which is the farthest from the distribution box When communication problems occur you can place an extra termination on another branch It is highly recommended to limit the number of terminations as too large a number may overload the bus 12 VMB4RYLD 4 channel relay module user manual version 1 Configuration This relay module can only be configured through the Velbuslink software The address behaviour and control functions can be configured manually Address Each module in the Velbus connection must have a unique address Configure the address through the software Relay Contact Behaviour The relay contact will behave as an NO contact no voltage on the outputs at no load With the software this behaviour can be modified to an NO contact at no load when the indication LED does not light the relay contact will be closed and the output will present a voltage Make sure however this occurs when the relay module is live Control Functions The relay module is controlled through pushbuttons connected to the Velbus system via a pushbutton interface or control panel You may assign up to 39 different pushbuttons Each pushbutton may activate a different function Function Description Momentary The relay remains switched on as long as the
6. the lighting in the attic The lighting will automatically switch off after a preset time A press of the pushbutton switches on the relay for a preset time A press of the pushbutton while the relay is switched on restarts the timer If desired the short and long press delays can be set This function is also called a staircase lighting timer A press of the pushbutton switches on the relay for a preset time A press of the pushbutton while the relay is switched on has no effect The relay status remains unchanged with the closing of the switch The relay is switched on for a preset time with the opening of the switch The relay is switched off with the closing of the switch The relay remains switched on for a preset time with the opening of the switch Nothing happens as long as the relay remains switched off At the release of the pushbutton the switched on relay will remain switched on for a preset time Pressing the pushbutton will switch on the relay after the expiration of the switch on delay The relay is switched off again after expiration of the switch off delay Pressing the pushbutton while the switch on or switch off delay is running will annul the timer and switch off the relay Pressing the pushbutton will switch on the relay after the expiration of the switch on delay The relay is switched off again after expiration of the switch off delay Pressing the pushbutton while the switch on delay is running wil
7. the pulse and pause time between 1 sec and 2 min in steps of 1 sec 2 min and 5 min in steps of 15 sec 5 min and 30 min in steps of 30 sec 30 min and 1 hour in steps of 1 min 1 hour and 5 hours in steps of 15 min 5 hours and 10 hours in steps of 30 min 10 hours and 24 hours in steps of 1 hour 2 days 3 days no switch off timer O O O O O O O O O O 16 VMB4RYLD 4 channel relay module user manual version 1 CHECKING THE SOFTWARE VERSION The software version can be verified via the Velbus link software Check on http www velbus eu whether you have the latest version If a newer version is available download it Connect the Velbus interface to a PC and run the upgrade software and follow the instructions on the screen Remark Upgrading a module is not without risk Do not interrupt the process If for any reason the upgrade should fail the module will cease normal operation The module will have to be returned to the manufacturer VMB4RYLD 4 channel relay module user manual version 1 17 18 HOME AUTOMATION by Selene What is velbus Products Virtual demo Downloads Pricelist Newsletter Links Professional Velleman eu e Lett Imagine coming home from a long day at work With a single button press you turn on the heating the blinds close several lights turn on and create a cosy intimate atmosphere The wall outlets which were shut off for safety reasons during your absence
8. UPPLY BUS L_IN N VMB4RYLD 4 channel relay module user manual version 1 Connecting a 230V mains voltage to the input allows you to switch 4 mains voltage consumers like lighting a pump an electric heater electric valves etc Connecting a 12V low voltage to the input allows you to switch 4 low voltage consumers like low voltage lighting LED strips low voltage LED spots etc The module is integrated into the Velbus system and controlled through the VMB4PD control panel or by means of pushbuttons connected to a VMB8PB pushbutton interface VMB6IN or any other relay module To interconnect the Velbus modules it is recommended to use a twisted pair cable EIB 2x2x0 8mm UTP 4x2x0 51mm CAT5 or equivalent Make sure to use a heavy gauge wire 0 5mm or more in case of a multiple module connection gt 10 modules or with log connections gt 50m Connect the bus to the module mind the polarity Ti SIN Tar Sn Tar SN T4 SIN O CCC CO OG LOAD1 LOAD2 LOAD3 LOAD4 A Kies A Ch relay module gt velleman VMB4RYLD Geer ZIL H CCCG OOO O OCO OC SUPPLY BUS L IN N BUS ue VISI rr I 12 18Vde 12 18Vdc VMB4RYLD 4 channel relay module user manual version 1 9 A double pole load e g mains outlet requires an extra double pole relay A triple pole load e g water heater requires a quadrupole relay Tir Sn rar Sn rar Sn rar SN 0 C
9. c 000000 LOADI LOAD LOAD3 LOAD4 4 Ch relay module VMBARYLD H l CCCG 70000000 L3 L2 L1 N H BUS L us SOCH 12 18Vde 12 18Vde 10 VMB4RYLD 4 channel relay module user manual version 1 The module is also suitable for controlling 12V or 24V LED bulbs or strips The input will then be connected to a low voltage power supply 12V or 24V Choose a power supply which can deliver the required consumption while the total consumption does not exceed 12A TSN Tar STN Tr STIN TE BTN C C CCC CC C LOAD1 LOAD2 LOAD3 LOADA I e LU NL DC OK AN V Switched Mode Power Supply VMBSMPS INPUT 100240VAC BA VE 4 Ch relay module 50 60Hz C K velleman VMB4RYLD OUTPUT 12V 4 5A ON Rx Tx CY GE E E Designed in Europe made in Terwan 0000 00000000 SUPPLY BUS NN 4 gt gt IN AVATA iE 12 18Vde 12 18Vde MADE IN TAIWAN ADJ BUS BUS i ES F T VMB4RYLD 4 channel relay module user manual version 1 11 Termination Remove the cover Tir BIN T2r BIN TI SIN 74 STIN C O O C CC C C LOAD1 LOAD2 LOAD3 LOAD4 OOC L INN SUPPLY BUS Generally only 2 TERM terminators must be used in a complete Velbus installation Usually this will be on one module inside the distribution box and on the module which is physically located furthest from the distribution box On all other modules the terminator must be
10. ced on mode pushbutton press Remark The forced on status can still be determined by the function forced off at opened or closed switch Inhibit at closed switch The relay is switched off as long as the switch is closed The functions will still be active internally The internal status will be transferred to the relay at the opening of the switch functions will still be active internally The internal status will be transferred to the relay at the closing of the switch Inhibit at pushbutton press Pressing the pushbutton will switch off the relay for a preset time The functions will still be active internally 7 Toggle inhibit at pushbutton Pressing the pushbutton will switch off the relay for a preset time Inhibit at open switch The relay is switched off as long as the switch is open The press The functions will still be active internally Repressing that same pushbutton will cancel the inhibition mode VMB4RYLD 4 channel relay module user manual version 1 15 Cancel inhibit at pushbutton Pressing the pushbutton will transfer the internal status to the press relay A light sensor will switch on the garden lighting at dusk A pushbutton on the control panel will inhibit the output at 23h00 a second pushbutton will cancel this inhibition at 06h00 via the weekly program This will keep the garden lighting switched off between 23h00 and 06h00 Some functions allow you to set the switch off time the switch on delay or
11. e the switching on of the relay for a preset time The use of a control panel with weekly program allows you to disable the output control of an output for a preset time Toggle forced off at Pressing the pushbutton will disable the switching on of the relay pushbutton press for a preset time Repressing that same pushbutton will cancel the forced off mode Cancel forced off at Pressing the pushbutton will cancel the forced off mode pushbutton press Remark The forced off status can still be determined by the function forced off at opened or closed switch Forced on at closed switch The relay is switched on as long as the switch is closed All other commands are ignored Remark The forced off function overrules the forced on function Forced on at open switch The relay is switched on as long as the switch is open All other commands are ignored Remark The forced off function overrules the forced on function Forced on at pushbutton press Pressing the pushbutton will switch on the relay All other commands are ignored for a preset time Remark The forced off function overrules the forced on function Toggle forced on at Pressing the pushbutton will switch on the relay All other pushbutton press commands are ignored for a preset time Repressing that same pushbutton will cancel the forced on mode Remark The forced off function overrules the forced on function Cancel forced on at Pressing the pushbutton will cancel the for
12. l restart the switch on delay Pressing the pushbutton will switch on the relay after the expiration of the switch on delay The relay is switched off again after expiration of the switch off delay Pressing the pushbutton while the switch on or switch off delay is running does not affect the general status Pressing the pushbutton will switch on the interval timer for a preset time The output is thus repeatedly open and closed The switch on and switch off delays can be set Pressing the pushbutton while the interval timer is running will stop the interval timer VMB4RYLD 4 channel relay module user manual version 1 Restartable interval timer Pressing the pushbutton will switch on the interval timer for a preset time The output is thus repeatedly open and closed The switch on and switch off delays can be set Pressing the pushbutton while the interval timer is running will restart the interval timer Non restartable interval timer Pressing the pushbutton will switch on the interval timer for a preset time The output is thus repeatedly open and closed The switch on and switch off delays can be set Forced off at closed switch The relay cannot be switched on as long as the switch is closed A light sensor will keep the driveway lighting switched off during daylight Forced off at opened switch The relay cannot be switched on as long as the switch is open Forced off at pushbutton press Pressing the pushbutton will disabl
13. on the relay and the timers remain enabled A long press of the pushbutton switches on the relay but the timers cannot be restarted Each press toggles the relay status on off Normal lighting control in a room VMB4RYLD 4 channel relay module user manual version 1 13 Toggle with timers disabled Toggle with timers disabled at short press Toggle with timers disabled at long press Start stop timer Restartable timer Non retriggerable timer Trigger on release timer Delayed off at release Delayed off at release only when relay is on Start stop with delayed on off Restartable delayed on off Non restartable delayed on off Start stop interval timer Each press toggles the relay status on off The timers cannot be started when the relay is switched on A PIR detector will switch on the driveway lighting this lighting can switched on off with a pushbutton A driveway lighting switched on through the pushbutton will not be affected by the PIR detector Each press toggles the relay status on off The timers cannot be started when the relay was switched on by a short press Each press toggles the relay status on off The timers cannot be started when the relay was switched on by a long press A press of the pushbutton switches on the relay for a preset time A press of the pushbutton switches off the switched on relay immediately If desired the short and long press delays can be set Control of
14. ons e through Velbus commands or pushbuttons connected to the Velbus system VMB4RYLD 4 channel relay module user manual version 1 3 e multiple control functions o moment off on on off timer start stop restartable or non restartable switch on off delay interval output forced off output forced on output inhibition etc O O O O O 0 0 0 Timer presets e only configurable through the Velbuslink software e timer presets configurable between o 1 sec and 2 min in steps of 1 sec 2 min and 5 min in steps of 15 sec 5 min and 30 min in steps of 30 sec 30 min and 1 hour in steps of 1 min 1 hour and 5 hours in steps of 15 min 5 hours and 10 hours in steps of 30 min 10 hours and 24 hours in steps of 1 hour 2 days 3 days no switch off timer O O O O O OOOO 4 VMB4RYLD 4 channel relay module user manual version 1 VELBUS CHARACTERISTICS 2 wire communication for Velbus data and 2 wires for power data transfer 16 6 kbit s serial data protocol CAN Controller Area Network short circuit proof towards or of power bus error indication 2 short blinks of the operation mode LED self restoring after 25 seconds in case of a bus error Possibility to assign a name max 16 characters to each output channel The relay module can send following messages relay status relay module type with software version channel names communication error counter memory capacity The relay module can send following commands
15. pushbutton is pressed The relay is switched off In order to create an all off function the same pushbutton of all relay channels will be configured as an off function ER Off with timers disabled The relay is switched off and the timers cannot be restarted Off with timers disabled at A short press of the pushbutton switches off the relay but the short press timers cannot be restarted A long press of the pushbutton switches off the relay and the timers remain enabled Off with timers disabled at long A short press of the pushbutton switches off the relay and the timers remain enabled A long press of the pushbutton switches off the relay but the timers cannot be restarted The relay is switched on May be used in a control panel with weekly program to switch on an output at a certain point in time On with timers disabled The relay is switched on and the timers cannot be restarted When a PIR detector is triggered the driveway lighting will switch on for 10 minutes A pushbutton with the On with timers disabled function allows to switch on the driveway lighting continuously without the PIR detector having an influence on the action On with timers disabled at A short press of the pushbutton switches on the relay but the short press timers cannot be restarted A long press of the pushbutton switches on the relay and the timers remain enabled On with timers disabled at long A short press of the pushbutton switches