1. through our web site http www nevion com Please contact Nevion s Customer Support for assistance with recycling if this site does not show the information you require Where it is not possible to return the product to Nevion or its agents for recycling the following general information may be of assistance Before attempting disassembly ensure the product is completely disconnected from power and signal connections All major parts are marked or labeled to show their material content Depending on the date of manufacture this product may contain lead in solder Some circuit boards may contain battery backed memory devices nevion com 8
2. NeEVIEN FC PWR 1RU Flashlink Compact Power Supply User manual Rev B FC PWR Rev B Nevion Support Nevion Europe Nevion USA P O Box 1020 1600 Emerson Avenue 3204 Sandefjord Norway Oxnard CA 93033 USA Support phone 1 47 33 48 99 97 Toll free North America 866 515 0811 Support phone 2 47 90 60 99 99 Outside North America 1 805 247 8560 E mail support nevion com See http www nevion com support for service hours for customer support globally Revision history Current revision of this document is the uppermost in the table below Rev Repl Date _ Sign Change description _ DEE HE a ee BEE EEE ae ee BEE EEE ae ee C d DoC d h E over page update DoC removed no other ES A changes to content 2012 08 02 First released document 2012 01 18 Initial document nevion com 2 FC PWR Rev B Contents RWIS IOI SLORY ee Renee 2 1 PROGUGE OVERVICW sci cnacciscs a ee 4 2 Speellicall ns mans ete oa eel ean eae eae 4 reais Wil S121 EEE E E EE eS OC rN ERROR NE Eee NN E E ee eee 4 3 POWEr CONNECHONS Zune ea shacgeeceaateesseaeees 5 4 Replacement of power supplies u2200220020000000 0000 nnne nun ennn nun nun anne nnnnnnnennne nennen 5 General environmental requirements for Nevion equipmert 2 02200220022senenenn 6 Product Waranty zus 7 Appendix A Materials declaration and recycling information cccecseceseeeeeeeeseeeeees 8 A 1 Materials deelamallon
3. eyes een ie 8 Ase Recycling INFOFMALON ansehe 8 nevion com 3 FC PWR 1 Product overview Rev B The FC PWR is a 120W 1RU redundant power frame enable to power up to 4 Flashlink Compact units redundantly The power supply has 8 power output ports and is delivered with 8 power cables The power supply features resettable fuses on every power output ensuring one faulty Flashlink Compact unit to not pull down the rest of the units 2 Specifications 2 1 General AC input voltage DC output voltage Max total output current per row 4 output ports Max total output all rows both power present non redundant Max power per port 100V 240V AC 12V 10A 20A 2 5A protected by re settable fuses nevion com 4 FC PWR Rev B 3 Power connections Be 12V dc Max 10A per row Figure 2 The figure above shows the pin out of the connector 4 Replacement of power supplies Disconnect Mains Lead Remove Power Supply Disconnect from unit nevion com 5 FC PWR Rev B General environmental requirements for Nevion equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating room temperature 0 C to 40 C range Operating relative humidity range lt 90 non condensing 2 The equipment will operate without damage under the following environmental conditions Temperature range 5 C to 50 C Relative humidity range l
4. t 95 non condensing nevion com 6 FC PWR Rev B Product Warranty The warranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Nevion which are available on the company web site www nevion com nevion com 7 FC PWR Rev B Appendix A Materials declaration and recycling information A 1 Materials declaration For product sold into China after 1st March 2007 we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products In the first stage of this legislation content of six hazardous materials has to be declared The table below shows the required information Toxic or hazardous substances and elements Toxic or hazardous substances and elements hazardous substances and elements HREH KTR SRKE R E Part Name a Pe nn Hexavalent Polybrominated Polybrominated Pb Hg Cd Chromium biphenyls diphenyl ethers Cr VI PBB PBDE SIRE 2 8 O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T 11363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SU T11363 2006 This is indicated by the product marking A 2 Recycling information Nevion provides assistance to customers and recyclers

Download Pdf Manuals

image

Related Search

Related Contents

Infusystemes France  UI Escalier de chantier-FR-0933.fm  Downloadable - BrandsMart USA  Emerson MR98 Drawings & Schematics  vänEE 100H and 200H User Manual (20509 rev. 03).indd  Garland All Purpose Oven User's Manual  (経済産業省と事故防止のための注意喚起) [PDFファイル/796KB]  M4348 Data logger NEW Language: English  聖闘士聖衣神話EX アリエスシオン ~聖戦Version~ 取扱説明書  Kenmore 153.330401 Water Heater User Manual  

Copyright © All rights reserved.
Failed to retrieve file