1. 1 System must include 2 independent high output LED illuminators with integrated hard coated fluorescence bandpass excitation and emission filters for each cube GFP 470 22 ex 510 42 em amp RFP 531 40 ex 593 40 em 2 Objectives included should be phase compatible 10x 40x and Oil immersion 100X objective 3 Compatible vessel holders should be provided for Dual slide holder amp Universal holder Biosafety cabinet ITI three 1 Quantity required 1 2 Safety of laboratory worker and safety of all staff while handling biohazard level II organism a biosafety cabinet III three is needed Airstream Class III biohazard safety cabinet General specification External dimensions 1340x850x2250mm WxDxH Internal work zone 1240x650x650mm WxDxH Number of glove ports 2 ports Air volume at initial 603 cmh 355 cfm velocity Cabinet negative 274Pa 1 1 in H20 exceeds pressure EN12469 2000 requirement of 199 3Pa 0 8in H20 and NSF49 requirement of 124 5 Pa 0 5in H20 Standards compliance Individually performance tested and certified at factory under controlled conditions for General requirement CCOO2 2 and AS1386 5 Air cleanliness ISO 664 1 class 3 IEST G CC1001 IEST G CC1002 and other equivalent air cleanliness requirements Filter performance IEST RP CC034 1 IEST RP CC007 1 IEST RP CC001 3 and EN1822 Electrical safety IEC 61010 1 EN61010 1 U
2. apparatus Temperature bath for determination of oxygen and carbon dioxide uptake and release during respiration inner chamber polished stainless steel tank geared motor and eccentric arrangement fitted to the unit to provide uniform oscillation of manometers immersion heater is fitted in the tank stirrer unit is provided to keep temperature uniform throughout the tank manometers are fitted on graduated scales or easy reading of pressure changes Warburg s reaction flask with central well and side flask are provided for each manometer Warranty Guarantee card and User s Manual to be provided 11 Haldens analyzer gas Gas analyzer used for quantitative and qualitative determination analysis of oxygen carbon dioxide methane carbon monoxide ammonia hydrogen etc Warranty Guarantee card and User s Manual to be provided 12 Spirometer 6 litre capacity stainless still chamber with chain compensates counter balance to float through pulley calibrated to donate volume inlet and outlet tubes complete with corrugated rubber tube and mouth piece Warranty guarantee card be included 13 Ion slective electrode ISE electrolyte analyser e Principle Direct measurement of ions with lons with ion selective electrode ISE e Sample whole blood serum plasma fluoride or heparinside CSF Urine Parameters Option of 2 3 or 4 ions from Na K Cl 1Ca Li Display 8 lines 20 characters line larg
3. 0 01 C or better 7 Bath Tank Depth At least 15 Cm 8 Bath tank area At least 200 Sq Cm 9 Capacity of bath tank 7 to 10 Litres 10 Bath tank body must be made of corrosion resistant stainless steel 11 Must have a drain port for completely draining fluids from the bath tank 12 Must have digital display of set and run parameters 13 Must include all tubings clamps and port adapters for external circulation 14 Safety Features Over temperature indication with audible visual alarms low water level in tank warning etc 15 Provision to on off the circulator pump as per requirement 16 Must have RS 232 interface for data logging applications 17 Electrical power requirement 230V 50Hz 18 Warranty At least two years from date of installation 19 Any other accessory that may enhance the performance of this system may be quoted as optional Double All quartz double distillation unit demountable boiler panel series Distillation vertical model Distillation water output 2 5 litre h 230 250 volt apparatus single phase 4 4 kw Minimum cooling water requirement 2litre min Biological activity pyrogen free Conductivity S em lt 1x10 TOC lt 500 microgram litre Organic matter nil total solids lt 0 1 meg litre Distilled temperature 65 75 C Total plate count zero Stanstandard plate count zero Yeast and mould zero KMnO colour retention 1h UV absorbance at 254 nm 0 007 10 Warburgh Warburg s
4. 0ul 6 The system should be sensitive quantifying samples with concentrations as low as 10pg ul of DNA and 12 5ug ml of proteins 7 The system should have internal memory storing at least 1000 analysis data 8 System should have Dynamic range 5 orders of magnitude 9 Processing time should not be more lt 5 seconds sample 10 Light sources Blue LED max 470 nm 11 Red LED max 635 nm 12 Excitation filters Blue 430 495 nm Red 600 645 nm 13 Emission filters Green 510 580 nm Red 665 720 nm 14 Detectors Photodiodes measurement capability from 300 1000 nm 15 Calibration type 2 or 3 point standard 16 Tube type 0 5 mL Real Time PCR polypropylene tubes 17 Warm up time lt 35 seconds 18 The system should at least have 1 year of warranty post installation MOBILE 1 Should be easy to use and controlled by Apple I phone 4 4S POCKET mobile phone SIZE 2 Should be able to screen more patients no stress or shaving VETERINAR required for most of the Animals Y ECG 3 Should be powerful and Clinical quality single lead ECG MONITOR recorder 4 Should provide better accuracy in rate and rhythm compared to traditional systems 5 Should Store email and record ECG s for print outs pH meter 1 It should be accurate and reliable to measure the pH of different media solutions buffers and other laboratory use 2 It should be able to measure the pH from 0 14 with resolution of 0 01
5. COLLEGE OF VETERINARY SCIENCE amp ANIMAL HUSBANDRY KUTHULIA REWA M P TENDER NOTICE No 557 Store Purchase 2015 Dated 15 01 2015 Sealed tenders are invited from the reputed firms manufacturers and their authorized dealers for the supply of laboratory equipments for CoVSc amp AH Rewa on terms and conditions as mentioned in the tender documents The tender documents including detailed specifications terms and conditions of supply can be directly downloaded from our website www mppcvv org Tenders may be submitted along with EMD and other documents positively by 06 02 2015 5 00 P M to the undersigned by Registered Speed Post Only Tenders will be opened on the 07 02 2015 at 3 00 P M DEAN College of Vety Sci amp AH Kuthulia Rewa MP ANNEXURE I TECHNICAL SPECIFICATIONS FOR THE EQUIPMENTS INSTRUMENTS ABOVE 1 LAKH Name of Technical specification of the equipments instruments for equipments Tender 2014 15 instruments 1 Fluorescent 1 System must be a single compact integrated unit including cell Microscope imaging system digital camera computer high power fluorescence lighting system and LCD display and imaging Software 2 Fluorescence LED light cube must be a single interchangeable cube can be easily removed and installed 3 Fluorescence LED illuminators must have a lifetime of 50 000 hours at 100 power 4 System must automatically recognize which cube is installed and adjust the software
6. Distance LWD phase contrast objectives Transmitted light LWD air objectives and coverslip corrected objectives e Objectives included should be phase compatible 10x 40x and Oil immersion 100X objective 6 Instrument should have Rack and pinion focus mechanism 7 Rack and pinion glide stage with SBS microplate opening and accessory vessel holders 8 Compact footprint the entire system should be easily moved into a cell culture hood or glove box 9 Instrument must have Low power consumption less than 20 Watts hr 10 Instrument should have On board software applications e Time Lapse with avi movie creation e Manual Cell Counting e Downloadable software updates e Multiple user accounts 11 Instrument should have One DVI port and three USB output ports 12 Direct output to USB or networked storage device 13 Supported output file formats jpg bmp tif and png Automatic distillation system for protein estimation Autosequencing Microprocessor based PC Compatible Distillation System with in built software with 50 Predefinable User Storage Auto Sequence Programmes Automatic sequencing with auto Intelligent run of programmable steps which include Automatic Dilution Automatic Boric Acid addition Automatic Alkali Addition Automatic Steam injection Process over indication with alarm with delay time features Automatic Titration Connectivity feature for future upgradation Microbrilliant distillate control with adju
7. L3101 1 CSA C22 2 No 1010 92 IEST RP Air cleanliness within working area ISO 14644 1 Class 3 US federal standard 209 E class1 M1 5 AS 1386 Class 1 5 JIS B9920 class 3 BS5295 class C Class M10 000 as per KS 27030 1 and other equivalent cleanliness classifications of the VDI 2083 and AFNOR X44101 main filter type ULPA filter with integral metal guards and filter frame gaskets fully compliant with EN1822 and IEST RT CC001 3 requirement Flow exhaust 2 ULPA filter with integral metal guards and filter frame gaskets fully compliant with EN1822 and IEST RT CC001 3 requirement Main filter efficacy ratings Down Minimum 99 997 at 0 3um 99 988 flow at 0 12um 99 987 at MPPS Typical 99 999927 at 0 3 wum 99 9977 at 0 12 pwm 99 9972 at MPPS Minimum 99 99962 at 0 1 3um 99 99965 at 0 12 um 99 99946 at MPPS Typical 99 999928 at 0 3 um 99 99996 at 0 12 um 99 999924 at MPPS exhaust a Minimum 99 99916 at 0 3um 99 99965 at 0 12 um 99 9982 at MPPS Typical 99 99983 at 0 3 um 99 99979 at 0 12 um 99 999971 at MPPS exhaust Pre filter Disposable and non washable polyester fiber with 85 arrestance EU3 rated Noise filter Typically lt 60dBA at initial blower speed setting measured as per EN 12469 2000 based on 4 feet cabinet subject to acoustic properties of test environment Light intensity gt 1200lux gt 111 foot ca
8. apparatus Should have quick snap electrode assembly Should have casting gates to cast directly in the electrophoresis cell Gel casters should offer the flexibility of accommodating several different size UV Transparent gel trays UV transparent tray for horizontal system 2 no Output Range programmable Approx Volts 10 300 V Current 4 400 Power supply MA Power 75 W Timer 1 999 min Display 3 digit LED No of Output k jacks 4 sets in parallel Safety Features No Load detection sudden load unit change detection overload short circuit detection over voltage protection Should have regulatory certification EN 61010 CE 21 A type amp California Cage Size 20 X 18 X 15 X 13 No of Birds 05 Box California A Cage Size 20 X 15 X 17 X 15 No of Birds 05 Box type Layer cages 22 Milk analyzer High measurement speed Inbuilt Fan for Indian weather Very high reliability amp Accuracy Separate serial ports for Printer amp P C Fat Range 0 12 Resolution 0 01 SNF Range 0 15 Resolution 0 01 Added Water 0 100 Resolution 0 01 Repeatability 0 05 Accuracy 0 10 Power Supply 120 220Vac TENDER FORM TERMS AND CONDITIONS OF TENDER FOR PURCHASE OF LABORATORY M s EQUIPMENTS DURING THE YEAR 2014 2015 29 The tenders can be received from the Office of the Dean College of Vety Sci amp A H Rewa by submitting the Indian postal Order or Deman
9. approx Comb 8 well Comb Thic 1 5 mm Capacity well 40ul ANNEXURE II TECHNICAL SPECIFICATIONS FOR THE EQUIPMENTS INSTRUMENTS UPTO RS 1 LAKH Name of Technical specification of the equipments instruments for equipments Tender 2014 15 instruments I BIND 1 Instrument must be automated western processing unit capable WESTERN of carrying out all steps from blocking to final wash SYSTEM 2 Should provide hands free convenience plussuperior sensitivity and reproducibility overtraditional manual methods 3 Instrument should not require any external power supply and should work on sequential lateral flow to provide more reproducible results 4 Instrument should allow Timely release of solutions using mechanical pressureand glass fiber embedded membrane 5 Should be compatible with both HRP and Alkaline phosphatase chemistry with both nitrocellulose and PVDF membrane 6 Should allow entire membrane development within 2 5 hrs 7 Should carry all essentials FLUOROME 1 Instrument should be a Fluorescence based quantification TER platform for DNA RNA and Proteins 2 The system should have Large 5 7 Capacitive LCD color touch screen to ensure precision 3 The system should have Automatic data logging and USB port for efficient data management 4 The system should display Standard curve after calibration completion 5 The system should provide long range of sample workable volume ranging from lul 2
10. bservation tube rotatable through 360 degree fitted with fungus resistant anti reflection coated prism compensating widefield paired eyepiece WF10x F N 20 and with right hand co axial low drive mechanical stage substage Abbe condenser 1 25 N A with iris diaphragm focusable with rack amp pinion and with blue Filter Plan Infinity Optics Excellent Field Flatness F N 20 Seidentopf Head hard coated stage with double slide holder Easily replaceable lamp Inward facing nosepiece upper limit stopper for prevent the specimen in high magnification observation Universal Power supply ensures constant voltage amp International Build Quality EOS series Interchangeable Lens Type Live View 18 mega pixels Digital Camera body having CMOS sensor with USB interface along with one zoom lens EFS 18 55mm rechargeable battery with charger USB cable camera software compatible 8GB memory card etc Inverted Completely integrated all in one inverted cell imaging system phase contrast microscope 1 Microscope should be a Single compact unit including inverted microscope digital color camera computer and LCD display and imaging software 2 Must have Long life LED illumination up to 50 000 hours 3 Microscope must have a Color camera built in to the microscope base 4 System should have a 5 position objective turret 5 Instrument should provide flexibility for wide selection of objective options e Long Working
11. configuration accordingly 5 LED illuminators must have independent intensity control 6 System must be able to simultaneously accommodate 4 fluorescent LED light cubes 7 System must include an integrated high sensitivity monochrome interline CCD camera with 1 4 million 6 45um pixels 8 System must be able to accommodate a minimum of 5 objectives at once 9 System must include a rack and pinion focus mechanism 10 System must include a rack and pinion glide stage with SBS microplate opening and accessory vessel holders 11 The entire system footprint including all computer and monitor components must not exceed a 18 5 deep x 14 0 wide footprint 12 System must consume less than 20 Watts hr with all illumination sources turned to the ON position 13 System must provide a 1 click RGB channel overlay 14 System must be able to sequentially acquire a phase contrast image and a fluorescence image with a single mouse click then overlay them automatically 15 System must include time lapse imaging capability with automatic avi movie creation 16 System must include manual cell counting capability 17 System must include free downloadable software updates 18 System must include multiple user accounts 19 System must have at least one DVI output port and three USB output ports 20 System must support direct output to USB and networked storage 21 System must provide the following output file formats jpg bmp tif and png Accessories
12. control 10 For quality of instruments cheque provide light cheque 11 Preset 10 point master curve with just two point calibration for adjustment 12 tube can use 12 x 60 mm 13 RLU LIA and QUAL assay mode for quantity and quality testing 14 Advance processor with software for data input results summary quality control results storage and inquiry 15 Built in printer 16 Users friendly software and easy to use 17 Instrument have ISO and CE certified 18 Local service engineer is available 19 Power supply 230 v FULLY AUTOMATE D 3 PART HEAMATOL OGY ANALYZER 20 Light weight not more then 10 kg 1 The system should be a fully automated 22 parameter 3 part heamatology analyzer and should include the three part differentiation in the form of Lymphocyte Mid cells and Granulocyte 2 The system should analyze with a minimum speed of 75 to 80 tests samples per hour 3 Sample volume should not be more than 25ul in normal mode and not more than 50ul in pre diluted mode 4 The system should display all the 22 parameters and the histograms The system should have open tube system and should have a automatic sample rotor to hold the sample 6 The system should have a minimum of 2 chambers for measurement of WBC and RBC 7 The system should work on the principle of Electrical impedence method and the sample aspiration should be through th
13. d Draft of Rs 1 000 or can be downloaded from the website of the University www mppcvv org up to 30 01 2015 before 05 00PM In case the tender has been downloaded from the website of the University tender has to be submitted along with Indian postal Order or Demand Draft of Rs 1 000 in the name of the Dean College of Veterinary Science amp Animal Husbandry Rewa contain separate envelopes and mention tender cost in block letter Tenders must be submitted in sealed cover addressed to the undersigned by Registered Speed Post only and with acknowledgement due so as to reach on or before 06 02 2015 up to 05 00 P M The cover shall bear the address of the tenderer and super scribed with the words The tender will be opened in presence of the tenderers or their authorized representatives at 03 00 P M on 07 02 2015 In case any tenderer fails to present himself on the appointed time the competent authority shall have the right to open any tender in the absence of the concerned tenderer or his representative The tender shall not be acceptable without the receipt of earned money security deposit in the shape of Fixed Deposit Receipt FDR only of Equivalent to 3 of the cost of each equipment item for Equipments issued by any Nationalized Bank duly discharged in the name of Dean College of Veterinary Science amp Animal Husbandry Rewa which will be refunded after warranty period The above amount of earnest money security shall be refunde
14. d in full if the tender is rejected The tenders are to be submitted in four envelopes Envelope A will contain FDR as earnest money security deposit for the items Envelope B will contain the detail specifications of different equipments and all other documents related to tender Envelope C will contain specifications in brief including name of the manufacturing company make model etc as per the enclosed proforma with appendix along with price bid for different items Envelope D will contain all the above three and tender cost envelopes All the envelopes should be properly sealed The above security is taken for due performance of the contract as per provisions of the conditions mentioned in tender form The same will be refunded on the expiry of the contract on successful completion of the supply with reference to specifications with proper supply and adjustment of any loss by way of purchasing the goods from other party parties in case of dishonoring of the indent for supply and deliberate non supply Specifications are attached as ANNEXURE I along with Terms amp Conditions Quantity of the items to be purchased will depend up on the requirement and their shall be no obligation to place order for any quantity of the item 10 11 12 13 14 15 16 17 18 19 20 2l 22 23 Reputed firms manufacturers and their authorized dealers should only submit the tenders for ANNEXURE I without which no tender
15. e difference in cost of purchase from open market on quotation basis and approved tender rate will be recovered from the security of the tenderer and or bills pending for payments it will be decided by the Dean Further defaulter firm who has failed to supply the goods within prescribed period may not be considered during next term or tender All leases during transit i e breakage and shortage etc will have to be supplied by the tenderer at his own cost within a period of 15 days from the date of receipt of such notices 24 25 26 2 28 29 30 31 32 33 34 35 36 The undersigned does not bind himself to accept only the lowest rates The tenderer shall not submit whole or any portion of the contract to any party or parties else the competent authority is free to cancel the contract and forfeit the security deposit The VAT TAX has to be shown separately which will be deducted by the institute and certificate regarding this will be issued by the institute All other taxes if any has to be paid by the supplier himself Excise duty sales tax with and without concession certificate and other levies if any should be shown separately and the total price of each item should be worked out incorporating the same Custom duty exemption certificate will be not provided for imported items Single rate should be offered for the entire tender period i e up to 31 03 2015 Rates quoted for less than this period are liable t
16. e graphic display e Keypad compact numerical keypad with YES NO keys for easy guidance of operation e Printer inbuilt noiseless 24 characters line thermal printer with ON OFF facility e Data storage 100 patient results and upto 90 quality control results of normal low high controls Additional data on USB e Calibrators On demand and automatic 2 point calibration every 4 or 8 hour e Sampling probe Stainless steel anti rust probe with automatic sampling and probe wiping e Electrode Ionophore based PVC polymer electrode which are maintenance free and low cost e Power supply 110 220 VAC 50 60 HZ 0 75 Amp Optional battery for 5 10 hrs e Reagents Compact reagent pack with RFID Radio frequency identification system to avoid wastage and monitor proper availability e Reproducibility lt 2 0 CV 14 ELISA 1 Elisa plate reader with u v and flate bottom microplate 2 Test mode end point kinetic multi analysis reader 3 Measuring system minimum 8 channel optical system 4 Light source tungstan halogen 12v 20w 5 Wevelength 8 filters position 405 450 492 630 6 Reading range 0 000 4 000 abs 7 Reading speed 5 secound in single wavelength and 10 secound in double wavwlength 8 96 well plate multiple test in single plate 9 Parameters can be modified and stored 10 Plate shaking facility with variable speed and time 11 Self cheking and clibration function facility 12 Linearity range
17. e use of syringe technology and not through SRV 8 The system should have a aperture of 70um for RBC and 100 um for WBC measurements 9 The system should be available with different sample modes like goat canine sheep cattle and other veterinary purposes 10 The system should have facility for high voltage pulse for cleaning of aperture after every sample analysis 11 The system should have manual and automatic calibration for the parameters of WBC HGB RBC PLT MCV HCT RDW and MPV 12 The system should have an easy to use menu driven user interface with touch screen with separate START button and with Status of the test LED 13 The system should have a minimum storage capacity of at least 10 000 tests with histograms of WBC RBC and PLT on board 14 The system should be able to perform only HB TC and DC when required without performing the other parameters like RBC and PLT for saving of reagents 15 The system should have an internal printer and should have an additional USB interface for connecting to an external printer 16 The system should be compact in size and should use minimum power of not more than 60W operating power 17 The system should be an CE approved product Deep Freezer gt 86 C freezer capacity 24000 samples of 2ml tubes gt Programmable Temp Range from 20 C up to 86 C in increment of 1 C even at ambient temp up to 32 C gt The Capacity should be 410 liter gt Low Power consumpti
18. g Chain 2 mm Thick 4 x 10 3 Nos 17 Thin layer chromatography Comprising of moveable applicator Spreader with built in arrangement 0 2 mm Perspex base plate 114 x 23 cm Aluminium oe Carrier Perspex spotting temp plate developing chamber with lid Five T L C plates 20 x 20 cm two T L C plates 20 x 5 cm scriber for marking lines micropipette and glass sprayer with rubber bellow With Chrome plated Brass Applicator With Aluminium Applicator 18 Chromatograph This is made of wood with glass on all four sides and on top internal y cabinet for surface is wax coated for solvent resistance Hinged top provided with paper rubber gasket for air tight closing and window with air tight door In chromatography f S lower portion heavy castors provided for easy movement Finished in natural colour nitrocellulose lacqure Supplied as standard equipment are two stainless steel troughs and six glass rod For accomodating 4 filter papers of 45 x 57 cm 19 Photo electric Compact digital blood end chemical analyzer with end point chemical colorimeter and biochemical analysis displayed on digital display high standard glass filters ranging from 400 680 wavelength complete the 6 8 Volt 250 mA tungsten lamp light source special selenium photo cell detector and sample system of 15 mm diameter matched glass cuvettes 20 Horizontal gel Gel size should be 7 X 10 cm which can resolve upto 30 samples
19. gt 0 999 13 Qc westguard multi rule automated qc alert 14 Open system test item and parameters can be added or modified 15 Large storege for 1000 test item and 1 00 000 results 16 Large colour display 17 Printer external jet printer multi form patient report 18 Built in portable computer easy to use the machine 19 Interface with rs232 usb and pc connection 15 ELISA micro 1 Microplate washer with interchangeable manifolds for 16 8 x 2 plate washer and 24 12 x 2 96 well or srips 2 Minimal residual volume lt 1lul well 3 Dispense precision cv lt 2 4 Built in internal plate incubatator temperature precision 37 0 3c 5 Itcould be wash flat u or v bottom plate 6 Manifold with two needles for aspiration and 2 for dispens avoid cross contamination 7 Warning for waste water and solution 8 Dispense volume 0 950ul and it could be adjestable 9 Washing cycles 1 to 99 10 Soaking time 0 to 999 secound 11 Shaking speed 0 to 999 secound 12 100 test programs can be stored in memory 13 It should be interface with rs 232 14 It should have large Icd display 16 Trevis 1 Size Height 2440mm Length 1700 mm Breath 860 mm Cross Bar 3 Nos 900 mm 2 Materials a Dia 2 G I B Class b Dia 11 4 G I B Class Cross Bar c Lock rod 16 mm round rod d Bottom Plate 4 mm size 75 x 150 mm e Cross Bar with chain and lock key f Trevis Bolt and Nut 5 8 x 5 4 Nos
20. n full or in part without assigning any reason s therefore it also reserves the right to place an order wholly or in part with one or more than one firm as they may be convenient to the College The submission of a tender by a tenderer implies that he has read all the terms and conditions of tender contract and is fully aware of the scope and specification of the supplies to be made He also must satisfy himself regarding the suitability and availability of the materials The tenderer who is not satisfied by our terms and conditions of the contract need not submit the tender The competent authority Dean College of Vety Sci amp A H Rewa reserves the right to increase decrease or withdraw any item items of supply during the contract under tender and the tender will be bound to comply without any claim for compensation The rates quoted shall be F O R delivery at College of Vety Sci amp A H Rewa for ANNEXURE I The rates quoted should be inclusive of packing and forwarding charges loading unloading handling charges freight full risk coverage insurance etc The supply of material of order should reach within 2 4 week to destination from the date of issue of supply order In case the tenderer fails to execute the orders of supply within the stipulated period the competent authority Dean College of Vety Sci amp A H Rewa will forfeit the security amount and will be free to make alternate arrangement for purchase of goods Th
21. ndles measured at work surface level zero background as per IEST RP CC00 2 Main body construction 1 5mmt 0 06 16 gauge electro galvanised steel with white oven baked epoxy powder coated finish Front widow construction Colourless and transparent UV absorbing 8mm 0 31 tempered glass Work surface construction 1 2mmt 0 05 18gauge stainless steel grade 304 Maximum 220 1144W 4 97 1164W 5 1180 5 13A power 240VAC A 6A consumption 50Hz 1 current Ph 110 130 1632W 13 6 162W 13 1668W 13 9 VAC 60 A 77A A Hz 1ph Net weight 351 5kgs 775 439 4kgs 527 3kgs 11 approx Ibs 969lbs 631lbs Max shipping weight 601 751 2kgs 901 5 kgs 1325lbs 1656 Ibs kgs 1988lbs Max shipping 1995x1300x 2245x130 2550x1300x dimensions WxDxH 2759mm 0x2750 2750mm mm Max shipping volume 7 13cbm 251 8 03cbm 2 9 12cbm 32 S8cdf 83 6cbf 2 07cbf VOLTAGE Voltage regulator of appropriate rating to STABILIZER be included to cope with 160 260V Trinocular microscope and digital SLR camera Complete with built in 6V20W halogen light illuminator with universal power supply 100V 240V through SMPS circuit quadruple ball bearing inward nosepiece focusing by co axial coarse and fine focusing controls high resolution Infinity Corrected Plan Achromatic Objectives 4x 10x 40x spring 100x oil spring with an inclined Seidentopf Trinocular o
22. o be rejected In case of any dispute arising out of this contract the arbitration power rests with the Vice Chancellor NDVSU Jabalpur whose decision will be final to both the parties If any dispute the legal area of jurisdiction will be Rewa M P Tenders once submitted by the tenderer cannot be withdrawn by the tenderer Tenderer has to write clearly the name address and telephone mobile number of the firm Photocopy of sales registration Original registration will have to be produced within a week for verification if the tender is approved Please quote the rates in Indian Currency A demonstration of the equipments supplied will be done at College of Veterinary Science and Animal Husbandry Rewa by the supplier free of cost An agreement accepting above terms and conditions and signed by authorised signatory should be submitted on a non judicial stamp of Rs 100 along with tender documents DEAN College of Vety Sci amp AH Kuthulia Rewa MP
23. on 8 7Kwh per day gt It should have S M A R T plus Diagnostic Software System Monitoring amp Reporting Technology Software built In for fault diagnosis or set point variance gt System should be single door with 5 compartments gt The freezer must have Heated air Vent to prevent ice formation with Spring Assisted plunger to remove vacuum for easy opening gt Performance Pull Down to 85 C 5 6 hours 5 5 hours 5 hours Sound 51 dBA 56 dBA 54 dBA Uniformity 5 C 5 C 5 C gt Heat Output 505 Watts 520 Watts 580 Watts gt The system should have Non Volatile memory amp Auto re start and Battery Backup for the display gt The system must come with 4 digit password protection for temp amp alarm set points gt CFC Free and HCFC free refrigerants with biodegradable Polyolester oil compressor gt High efficiency freezers use high efficiency vacuum insulation panels in addition to a think polyurethane providing a full 130 mm thick layer for superb insulating efficiency PCR Format 0 2 ml tubes 96 well plate Capacity 96 x 0 2 ml tubes 1 x 96 well plate Block Format 0 2 ml Alloy Block Reaction Volume Range 10 80 uL Reaction Speed Fast Standard Accuracy 0 25 C 35 C to 99 9 C Program Features Auto re start after power outages Program overwrite protection Dimensions Height 24 5cm 9 6 in Width 23 7 cm 9 3 in Depth 48 5 cm 19 1 in Weight 11 4 kg 25 b Tempe
24. pH 3 It should have simple 1 2 or 3 point calibration routine with automatic buffer recognition plus a sensor efficiency function to ensure the most accurate data 4 The instrument should be powered by batteries or through AC power 5 It should have keypad with a large easy to read backlit display ideal for the lab 6 It should have laboratory grade pH mV temperature sensors 7 It should have large backlit display and easy to use keypad 8 It should have ATC temperature sensor or manual input 9 It should have sensor efficiency check function to ensure data integrity 10 It should have Calibration check facility amp Calibration Error indication for 7 00 amp 4 00 pH 11 All accessories required for function of instrument should be provided with the instruments 12 It should have 2 year instrument warranty Meat Mincer 350 watt Capacity 5kg with Kebbe attachment 3 die plates Rotary Automatic retraction Cassette holder Knife holder base Object microtome orientation unit Section waste tray Disposable blade Pack of 50 semiautomati Blades c Technical Data Section thickness Setting values Trimming sections Thickness setting range Setting values Specimen Retraction Motorized operation Horizontal specimen feed Vertical specimen feed Sectioning modes Maximum Specimen Size Specimen Orientation Operating voltages Nominal frequency Dimensions basic instrument
25. rature Range 4 0 99 9 C Temperature Uniformity lt 0 5 C 20 sec after reaching 95 C Platform Thermal Cycler Ramp Rate Max Block Ramp Rate 3 9 CSec Max Sample Ramp Rate 3 35 C Sec Product Size instrument Tm Calculator Menu driven through touch screen Display Interface 6 5 in VGA 32k color with touch screen Instrument Memory USB and On board Regulatory Statement For Research Use Only Not for use in diagnostic procedures High Throughput Compatibility High Throughput Compatible gt The system should be a 96 well Thermal Cycler with 6 separate peltier blocks to provide independent temperature zones to run six different assays with varying annealing temperatures at the same time gt Each block to accommodate 16 wells and having the ability to set up PCR with a specific temperature differential of up to 5 degree centigrade between blocks Mouse or stylus free navigation capability with VGA colour touch screen allowing for easy intuitive graphical user interface programming Scalability capability to interlink up to 11 PCR systems via single Ethernet hub The machine should be duly certified authorized for PCR process and the vendor should produce the certificate for the same With Horizontal GEL Electrophoresis 1 Submarine Tank with comb slots 2 Power supply 50 100V 3 Acrylic comb pre height adjusted 4 Connecting cord Gel Size 100x70mm Dimension MM 160x80x20mm Buffer Vol 170ml
26. s Weight including hand wheel Depth including waste tray Height with storage cover Section Thickness Setting range 0 5 mm to 90 mm From 0 5mm increments From 1 mm increment Imm in 0 5mm 99mm in Imm 0 5 mm99mm From 0 5mm increment From 1 mm increment Imm in 0 5mm 99mm in Imm Varying with section speed Approx 30 mm Approx 60 mm 1 manual mode 50mm L x 60mm H x 40 W Horizontal 8 Vertical 8 Z 360 Nominal supply voltages 100V 120V 230V 240V 50 60 Hz 390mm 510mm 305mm Weight with accessories Approx 26 Kg Centrifuge Table top model step less speed regulator with zero start interlock and dynamic brake digital speed indicator 0 99 min digital countdown timer imbalance detector with cutoff safety lid interlock to prevent cover opening during centrifuge speed should be between 15000 20000 rpm RCF 27440xg with two rotors 12x15 ml and 24x1 5 ml and connected load 0 8 KVA Water Bath Fully programmable microprocessor controlled refrigerated as well as heating circulator water bath with following features 1 Bench top model convenient to place on a work bench of 30 inch width 2 The bath can be used for internal as well as external temperature control applications 3 Working temperature range lt 10 C to gt 150 C 4 Heating Capacity 2KW 5 Circulating Pump Capacity gt 20 Litres Minute 6 Temperature Stability
27. stable sensor Two line Alpha numeric Digital LCD Display Inbuilt safety features with CE Certification to fulfill all statutory requirement of Good laboratory Practice Automatic sensing of no water condition in the condenser with auto alarm and warning signal to alert user Auto deactivation of operation after few minutes of warning on no water condition in case of user non availability Automatic measuring and monitoring of high temperature in distillate with auto warning signal and alarm to control distillate temperature Auto door open warning indication Auto tube insert error indication Auto deactivation of System on error diagnosis Automatic Reagent level sensor with alarm Adjustable steam power Auto online water saving mechanism Stainless steel non corrosive steam Generator Perilstatic pump for reagents addition ISO 9001 2008 Certified Electrical Requirement 220 230V 50Hz Hormone analyser 1 Measurement double tube mode and stat function 2 spectral range 400 600 nm 3 Touch screen display 4 Ultra low noise PMT with single photon counting 5 More than 100 test can perform 6 Tumors marker fertility thyroid torch cardiac drugs kidneys one metabolism anemia cardiac hepatic ebv hepatitis and others test can perform 7 Ceramic piston pump with two injectors 8 Small RFID label for all information of reagent and calibration 9 Kits should have 2 calilbrator and 2
28. will be accepted In case authorized dealers is submitting the tender certificate of authorized dealership from the company should be enclosed along with the tender The tender should be accompanied by detailed printed technical literature in original both hard amp soft copy specification make and model number of each item and each sub item quoted in the tender Specifications given in the offer must match to the printed technical literature Please compile a comparative chart of required specifications with your quoted specifications which is mentioned in your original literature both soft and hard copy Please provide maximum discount No further negotiation will be done No person or Firm is permitted to submit more than one tender under different names Tenders shall not be accepted without sales tax registration number of the firm All tenders must be accompanied by an Income Tax clearance certificate pertaining to the financial year 2013 2014 assessment year 2014 2015 without which the tenders shall not be entertained or in exceptional case where the income tax department has given a certificate that the concerned firm has been newly started Tenders will be accepted only from those dealers who pay regular income taxes The rates of tender shall not be altered by the tenderer during the contract of supply The competent authority Dean College of Vety Sci amp A H Rewa reserves the right to accept or reject any or all offers i