Home
USER MANUAL
Contents
1. After discharge signalising appears an accumulator should be charged as quickly as possible by connecting external feeder Charging is more effective when scale is turned off with I O key then charging time is about 10 hours It is also possible to connect accumulator directly to PA6V charger leaving accumulator in a scale or take it out if needed In order to take accumulator out take off a pan disconnect accumulator wire and unscrew mounting screws Charging an accumulator through scale feeder 230V feeder g scale Charging an accumulator directly through charger 230V feeder p charger a scale USER MANUAL 11 10 Balance checking It is advised to check scale indication accuracy before and after series of measurement using any load with known weight To check the scale with legal verification use a calibration weight with valid calibration certificate In case permissible error is exceeded it is advised to contact the nearest service to calibrate the scale 11 Scale adjustment To adjust a balance it is necessary to break protective marks therefore to calibrate the scale please contact the nearest service 12 Connecting a computer or a printer optional The scale is equipped with RS232C or RS485 optional which can be used to RS 232C connect external devices such as a computer or a printer When cooperating with a printer data is send automatically after resu
2. USER MANUAL B SERIES File R B 043 04 09 B42_0 GB USER MANUAL Contents 1s MBCNCKal OOSCHOUON sireva a n O a E EAA EEE iaa 3 De SOTTO SS erai a atl a ted tala ae Ait eens a afc E 3 same fo 0 ore 6 f 2 Reem enter sere repre ne crear reser A E A EAA 4 4 Keys and MAGIC AION S assesses eccteesaucas fatnea niteatesee besa cacwelan ets cule ecbetatananabstnG cacteine ced deuanceoianedie 5 CSE 521611101518 TUES ener ee ee a RR eee ea nee 6 6 Environment protection i is ctecens tt 2 etesewtartasd eetstetn ities Gatnv aun eed boaGamanee 6 7e Preparati oeei meee preter e rer cer trren pene a en ere errr rye tet Ter 7 8 Start Ups hran a a a a a a a 8 9 G neral Ulos reana E A E AR 9 10 Balance CHECKING oeiee naan en araara E ea aAA EREEREER E IRER 11 11 Scale adjustments rene anarei RE eT ea O ERE 11 12 Connecting a computer or a printer optional cccssesessscsessssssnsesssessseeees 11 13 Special functions description ss2e1s51s01s1151en1eresrenreresrenrerrnrenrerrsrenrerrnrenrerrnreneene 14 14 Normal WEIGHING ee via irainen anaa aiena eR EA ERER E TERRE 15 POs Weighing With tal nresnani A OE TREA 15 16 Increased readability wasadescustensnsAvecziizctioanseded caestteeas Pipecinetiocsisnledertanas Mieabinalted 15 17 Autozer SAID seco ras ose ier eae aca eet an aa eee 16 18 Funkejaiczenia sztuk FPCS cccscscscs eco cares sideeta sade eieamayeeesaiats 17 19 Printer cooperation settings FALP
3. WAGA KOMPUTER N 14 USER MANUAL 13 Special functions description All scales beside basic functions like weighing and tare are equipped with the set of additional functions Basic set of user special functions consists of autozero AUD pieces counting PCS constant tare tAr serial port working mode setting LP serial port parameters setting rS menu customisation 4Cf Other special functions can be enabled as an option on customer request all functions are described in additional brochure when ordered Press MENU key to enter the function menu Functions are displayed successively with consecutive numbers F PCS F 2 A Ut etc To customise the function menu with most frequently used functions use Menu Customisation function AC When switching between special functions MODE indicator is displayed To make clear how to manage with each function in further part of instruction descriptions are replaced with pictures Every time the picture of a hand appears press the indicated key Legend o puta load on the pan s remove the load from the pan 2 30 FF press the key when indication is b displayed forced change v automatic change USER MANUAL 15 14 Normal weighing 0 lt key which zeros the scale 0 00 Po operates only when the pan is empty v Wei
4. high resolution zero indicator result stabilization indicator net weight indicator indication with subtracted tare gross mass after use of B G key indicator of pieces counting indications in pieces LCD option special function setting total load indicator graduated 0 100 standby gross mass key B G pieces counting metrological parameters and accuracy class USER MANUAL 5 Security rules To avoid electrical shock or damage of the scale or connected peripheral devices it is necessary to follow the security rules below All repairs and necessary regulations can be made by authorised personnel only To avoid fire risk use a feeder of an appropriate type supplied with the scale Pay attention that supply voltage is compatible with specified technical data Do not use the scale when its cover is opened Do not use the scale in explosive conditions Do not use the scale in high humidity If the scale seems not to operate properly unplug it from the mains and do not use until checked by authorised service 6 Environment protection According to legal regulations it if forbidden to dispose wasted electronic equipment in waste containers Please return wasted scale to the point of purchase or other company specialised in recycling of wasted electronic components USER MANUAL 7 7 Preparation 1 Take the scale out of t
5. Computer Scale S S CR LF 53h 53h 0Dh OAh Scale Computer without response scale zeroing calling 0 lt key press Computer Scale S Z CR LF 53h 5Ah 0Dh OAh Scale Computer without response entering to special function menu calling MENU key press Computer Scale S F CR LF 53h 46h 0Dh OAh Scale Computer without response setting low threshold value Computer Scale S L D DN CR LF 53h 4Ch D1 DN 0Dh 0Ah D1 DN threshold value maximum 8 characters negative value digits dot decimal separator number of digits after dot should be the same as on USER MANUAL 13 scale display Scale Computer without response Example in order to set low threshold 1000g in scale B1 5 d 0 5g the following order should be sent SL1000 0CRLE 53h 4Ch 31h 30h 30h 30h 2Eh 30h ODh OAh in order to set low threshold 100kg in scale B150 d 50g the following order should be sent SL100 00 CRLF 53h 4Ch 31h 30h 30h 2Eh 30h 30h ODh OAh setting high threshold value Computer Scale S H D DN CR LF 53h 48h D1 DN 0Dh OAh D1 DN threshold value see Scale Computer without response Note Network number different than zero F rS nr function changes scale working mode communication with a computer is possible after logging the scale in with 02h scale number command To log the scale out use 03h command Connecting cable WK 1 scale computer 9 pin interface
6. FF buttons hy A measurement is performed in two v phases first phase single piece weight calculation on the basis of defined 23 40 MENU pieces amount 5 10 20 50 100 WwW hy 200 or 500 pieces second phase pieces counting F PCS F hy It is advised that single piece weight v is not less than one reading unit and sample weight used in first phase is F 0 bigger than 100 reading units NZ To leave function press MENU key FE 4 E and then with gt T key chose h F PCS and F 0 Notes 1 Err 3 communicate signalises that a sample was not put on the pan The same communicate appears if single piece weight is less than gt F one reading unit it is possible to hy count pieces but measuring error is bigger 2 To chose previously used pieces amount select in first phase in case no value was chosen error communicate appears 3 During pieces counting T lt key function does not change 4 In scales equipped with LCD display weighing unit is visible and sign is replaced with pes 18 USER MANUAL 19 Printer cooperation settings F LPt 0 00 MENU v b F LAt pE v b F 0 NZ F 1 FE v 0 00 Acti
7. incon wes efccdss costa econ ned facie ea eens 18 20 Serial port parameters Setting F rS csceccsccscssssssssessssssssssssessssssssesssssnseseesenes 19 Dis Gonstantlare SIAN stot oo cola a te cet ate ace Occ desde lat aca diy 20 22 Function Menu customisation F ACt ccccccccccssssssscssssssessesssessecssscssssssessenssanes 22 23 Maintenance and repairs Of small defects ccccscscssssseseseeessssessscssscssssssenenensesees 23 Decl rati n of Conformity snuisteren arana a a a a a eats 24 USER MANUAL 3 1 General description B series platform scales are destined for general use All scales are metrologically tested calibration or legal verification on demand B series scales are made in two main versions with LED display basic and with LCD display option Standard indicator may be changed by indicator with additional keys see appendix B Scales have following verification features a seal protecting scale casing against opening notified body stamps and green metrological marking placed on the balance name plate Legal verification is valid for 3 years unless the seal is broken NACE classification 29 24 23 Certificates pr tCse a PA TSO cl j 2 TM PE Ce oy aS Po oD EC Type Health Quality AXIS management System Approval Certificate Certificate Certificate No PL 04 022 No HZ 06458 01 DIN EN ISO 9001 2000 No 78 100 6386 2 Completeness Standard set consist
8. of 1 Scale User Manual Guarantee card Feeder ZN12V 500mA option Charger PA6V option aa es 4 USER MANUAL 3 Technical data Scale type B15W B120 B150 B200 B300 Maximum loading 15kg 30kg 60kg 120kg 150kg 200kg 300kg Minimum loading 100g 200g 400g Reading unit d 5g 10g 50g 50g 50g 100g 1g 5g 10g 10g 10g 10g 1g g Accuracy class a ees eee Working temperature Weighing time Scale height 740mm Power supply 230V 50Hz 8VA Internal feeding option accumulator 6V 12Ah Accumulator working time ok 50 godz Scale weight 13kg 23kg 23kg 21kg 35kg 35kg 35kg EC Verification Scale type B151 B152 B301 Maximum loading 30kg 60kg 150kg 150kg 300kg Minimum loading 200g 400g Reading unit d ie ri one 10g 10g 10g g Accuracy elass x160mm x130mm x160mm 740mm 230V 50Hz 8VA accumulator 6V 12Ah ok 50 godz opcja EC Verification increased readability for non EC verification applications USER MANUAL 5 4 Keys and indicators metrological data key I O key gt Te key gt 0 lt key E key MENU key B G key HR indicator gt 0 lt indicator er indicator NET indicator indicator 5 indicator MODE bar indicator indicator OFF indicator B G indicator pcs Max Min d e II switch on switch off standby tare subtract package weight from weighed mass zeroing when the platform is empty result printout special function menu gross
9. at the aaa left presents how to set transmission speed value to 9600bps PANY EE j j keni hy To leave the function choose out option Odd FF Send gt T v hy nr br v hy out T 20 USER MANUAL 21 Constant tare F tAr This function enables to measure gross weight of a sample placed in a container of a known weigh value stored in the memory and to display calculated net weight of the sample Tare value is recalled from the memory with gt 0 lt key when the pan is empty Tare value may be entered using the keypad or by sampling container weight from the pan Operation sequence e MENU v b F tAr PF v F 3 ee v b E04 0 v bb 1 vo 1 EE v b 1 0 Fod E0 v bb 1 7 MENU Tad b 0 00 The following options are possible F 0 leave the function F activate the function with the previous tare value F 2 sample tare value from the pan F 3 enter tare value with keys gt 0 lt gt T and MENU If the function is NET indicator is displayed active Options F enables to activate the function with previous tare value after leaving the function with F 0 option Note Tare value is stored in memory also after unplugging the sca
10. ed out by Laboratorium Badawcze Oddzia u Instytutu Elektrotechniki in Gda sk accredited by PCA EC Type Approval Certificate No PL 04 022 was issued by G wny Urz d Miar in Warsaw Notified Body no 1440 Gda sk 5 09 2006 r Per pro Director of AXIS Sp z 0 0 Production Manager Jan Ko czak ignature
11. ghing result should be read when gt a the indicator 4 lights 2 30 15 Weighing with tare The scale is equipped with tare equal to its range 2 30 FF v NET 0 00 To display gross weight press B G v key NET 40 01 Note fh Press B G key to return to net weight indication v 42 31 16 Increased readability Press HR key to display the weighing 2 30 A result for 5s with the highest readability possible This function is 7Y hy especially helpful in scales with legal verification with d e 2 29 The weighing result with increased wd readability can be used for informational purposes only and cannot be printed or sent to a computer with k key 2 30 16 USER MANUAL 17 Autozero F AUt w 0 01 mw v b F AUT FF v F 0 v F 1 pF v 0 00 When F Aut function is activated the scale automatically ensures stable zero indication if the pan is empty or if zero indication was acquired by pressing 7T lt key To leave the function press MENU key then with 7 lt key chose F AUt and F 0 Note Autozeroing function is activated automatically for 10 min after switching on USER MANUAL 17 18 Pieces counting F PCS This function enables to count identical pieces e g turnbuckles or 0 00
12. h a tare equal to its range To tare the scale press T lt key left or right Storing a tare value does not extend measuring range but only subtracts it from a load placed on a pan To make weight control easier and to avoid range overdrawing the scale is equipped with a load indicator graduated in percentages 3 Weighing result should be read when the indicator 4 lights which signalises stabilisation of a result 4 When the scale is not used but it is necessary to be ready to work immediately it can be switched off by pressing I O key The scale reading system is then switched off to standby mode signalled by the indicator OFF in version with the LCD display To switch the scale on press I O key The scale is immediately ready to operate maximum accuracy after self tests 5 Weighed sample should be placed in the centre of the pan Place the scale on a platform to avoid dropping weighed objects on the pan Do not overload the scale more then 20 of maximum load Max 6 Protect the scale against dust aggressive dusts and liquids To clean the scale wash it with water with soap and dry it afterwards 7 A scale equipped with lead acid accumulator automatically controls accumulator state signalises its discharge on LCD display and after around 1h a scale switches itself off to avoid discharging the accumulator below threshold voltage AN Do not discharge an accumulator because it can be damaged 10 USER MANUAL
13. he package removing protective foils 2 Take a pan off and remove protective elements from below the pan 3 Place the scale on a stable ground not affected by mechanical vibrations and airflows 4 Level the scale with the rotating rear legs so that the air bubble in the water level at the back of the scale is in the middle Lock Correct Wrong the legs with the nut 5 Put on the pan 6 Remove everything from a pan and plug a scale to the mains with a ground contact After self tests and result stabilisation the scale displays zero indication To feed a scale use only socket with a ground connector 7 In scales with external feeder connect feeder plug to a connector on a display post Plug a feeder to the mains 230V ground connector is not necessary 8 USER MANUAL 8 Start up Leave the pan empty plug a scale to the mains with a ground contact The scale proceeds with following start up actions FS Sue Display test WwW C l Basic electronic components tests CZ C 2 C 6 C 6 WY b Program version R 0 mia OG The scale is now ready to work USER MANUAL 9 9 General rules 1 Before each measurement make sure that zero indicator is displayed If zero indicator does not displayed or communicate appears press gt 0 lt key and wait until zero indication and zero indicator appears 2 The scale is equipped wit
14. le from the mains USER MANUAL 21 Weighing with constant tare 1 70 bO NET 10 00 BG 13 70 When tAr function is activated press gt 0 lt key to zero the indication and to recall tare value from the memory Tare value is displayed with sign B G key enables for instant switching between net and gross weight Note When the pan is empty 7 lt key does not operate to tare the scale use 0 lt key 22 USER MANUAL 22 Function Menu customisation F ACt 0 00 IMENU v F ACt PF v b F AUt z z F rS k F 0 Z F 1 PE This function enables to select special functions that will be displayed after pressing MENU key Easy access to the most useful functions will shorten operation time and make work more comfortable Operation sequence shown on the picture presents how to add RS232C parameters setting function F rS to the Function Menu To remove a function from the Function Menu choose F 0 in the last operation USER MANUAL 23 23 Maintenance and repairs of small defects 1 The scale should be kept clean 2 Take care that no dirt gets between the platform and the scale base If found any remove the pan lift it up remove dirt and then replace the pan 3 In case of i
15. lt stabilisation but next transmission is possible after removing previously weighted sample RxD receiver TxD transmitter GND Case The scale sends following information successive number of weighing and weighing result see printer cooperation mode setting The scale may be equipped with the second A Pinout interface optional used for example for B continuous weighing result transmission to A h an additional external display B When cooperating with the scale a computer should be equipped with a program which enables processing data from the scale available in AXIS with extra charge Case 12 USER MANUAL Computer cooperation protocol A scale sends data with following settings Communication parameters 8 bits 1 stop bit no parity baud rate 4800bps Available orders and scale responses initialising signal data send order Computer Scale S I CR LF 53h 49h 0Dh OAh Scale Computer scale response according to description below 16 bytes Description of response bytes Byte l1 signor space Byte 2 space Byte 3 4 digit or space Byte 5 9 digit decimal point or space Byte 10 digit Byte 11 space Byte 12 k l c porspace Byte 13 g b t cor Byte 14 space Byte 15 CR Byte 16 LF scale tarring calling 7 lt key press Computer Scale S T CR LF 53h 54h 0Dh OAh Scale Computer without response scale turning on off calling key press
16. mproper operation caused by short lasting power supply decay unplug the scale from the mains and then plug it again after few seconds 4 If the scale is switched on with empty pan and Err b communicate appears the load cell has been mechanically damaged 5 It is forbidden to make any repairs by unauthorised persons 6 To repair the scale please contact our nearest service Error communicates Communicate Possible cause Remedy C l 6 over min selftests failed if displayed more than 1 minute contact an authorised service not appear Err b the scale was switched on with loaded pan _ remove a load from the pan mechanical damage of the load cell contact an authorised service L pan missing put the pan on mechanical damage contact an authorised service H overloading remove the load from the pan mechanical damage contact an authorised service place the scale on a stable unstable ground e n ground not affected by vibrations ae mechanical vibrations and indicator does air flows airflows scale is damaged contact an authorised service taring in progress as above taring could not be finished the load is too small or B G key was used zero the scale or press B G key again the load is too big to be zeroed tare the scale T lt 24 USER MANUAL Declaration of Conformity We AXIS Sp ka z 0 0 80 125 Gdansk ul Ka
17. rtuska 375B confirm with all responsibility that scales B1I5W B30 B60 B120 B150 B200 i B300 oraz B33 B63 B151 B152 B301 marked with CE mark comply with the following 1 EN 61010 1 standard Safety requirements for electrical equipment for measurement control and laboratory use General requirements harmonized with the directive 73 23 EEC Low Voltage Directive 2 EN 55022 2000 standard Limits and methods of measurement of radio disturbance characteristics of information technology equipment and IEC 61000 4 3 Electromagnetic compatibility EMC Part 4 3 Testing and measurement techniques Radiated radio frequency electromagnetic field immunity test harmonised with the Council Directive 89 336 EEC Additionally scales with the following markings on the name plate C a sticker with two digit number of the year in which the mark was XX 1443 affixed and the number of the Notified Body responsible for EC verification a green metrology sticker with M mark a protective seal affixed by the Notified Body comply with requirements stipulated on the EC Type Approval Certificate No PL 04 022 and was verified by Notified Body No 1440 to comply with 3 EN 45501 Metrological aspects of non automatic weighing instruments harmonised with the Council Directive 90 384 EEC amended with 93 68 EEC Additional information Conformity evaluation for the Council Directive 73 23 EEC and 89 336 EEC were carri
18. vate the function for automatic serial port working mode cooperation with a printer After activation the scale prints a header Weighing result with a successive measurement number is printed automatically after result stabilisation without using gt key To select computer cooperation mode EG key activated and weighing results without successive numbers press MENU key then with gt T key chose F LPt and F 0 USER MANUAL 19 20 Serial port parameters setting F rS using L gt key approx 10 results per 4800 second SEnd 0 1 0 00 MENU The function enables to set the WwW hy following transmission parameters standard parameters underlined F S G transmission speed bAud 1200 4800 9600 hd h the number of bits in a byte bit 7 F 0 8 parity control PArItY 0 1 Odd 0 SF 1 _ network number when working in F 1 bE multistand computer system when hn working as a single scale the value should be 0 baud th continuous transmission without SZ Default parameters underlined 9600 pT To set desired transmission Ww hn parameters activate F rS function choose appropriate parameter and bit gt F press T key to accept needed hn parameter value The example