Home
        SANbox Manager Release Notes Version 1.03.28
         Contents
1.   the port and provides the highest level of test coverage of the three types of port  tests    o The online test can be performed on any port with an active login     e Remote logging via syslog   Logs can now be spooled remotely as well as being written to  local flash  To use this feature  select    Enable Remote Logging  syslog     from Network  Properties  Once selected  you need to enter an IP address of a UNIX machine that is  running syslog in the    Logging  syslog  Host IP Address    box  Refer to the SANbox2  Firmware Release Notes for an example of how to set up logging on the UNIX machine     Platform requirements    Host OS Windows NT  Windows 95 98  Windows 2000  Linux  RedHat 6 2   Solaris  2 8   Memory 128MB   Disk Space 150MB per installation   Processor 300MHz    Patch Requirements   This version of SANbox Manager uses  and includes  Java 2 SDK  Standard Edition  v1 4 0  The  SUN site below references patches that are required to be installed on your Solaris system in order  to work with this version    http   java sun com j2se 1 4 install solaris patches html    Documentation    Installation  setup and management of the SANbox2 switch are described in the following manuals   These manuals are available on the SANbox2 distribution CD     e SANbox2 Switch Management User s Manual  Publication No 59022 03 Rev  B  e SANbox2 16 Fibre Channel Switch Installer s User s Manual  Publication No 59021 03 Rev  B    Installation  setup and management of the SANbox swit
2.   there are  intermittent performance problems  This is noticed by occasional short delays in  processing requests and or the switches not responding  blue status icons  for a few  seconds        4791    When running offline online tests on E_Ports  the GUI will occasionally show a port as  offline when it is actually online and operational  A workaround is to do a fabric  refresh  The correct port states will then show up        4792    When changing the switch configuration in telnet back and forth between offline and  online  the GUI got into the state where it believed the switch was in the offline state   A refresh will correct this problem        When running from a remote login  the font size used for the text in the Help file is too  small to read   This is just an X Window font config issue   Edit  or create  a  Xdefaults file in your home dir    for root  and put the  following lines in it   Netscape documentFonts xResolution iso 8859 1  100  Netscape documentFonts yResolution iso 8859 1  100  While the above changes may provide a solution  in some cases it may not  In such  cases  the user may also be able to resolve the small font size by modifying the font  preferences in Netscape to be  Use my default fonts  overriding document specified  fonts         4814    If a saved fabric is restored and has a switch with a Domain ID that conflicts with an  active switch in the fabric then the fabric is not displayed correctly  ISLs are not  mapped correctly in the fabric 
3.  Rediscover of the fabric will display them correctly        4818    The GUI may lock up during fabric rediscovery after doing zone deletion  creation  and  merging  The GUI will repaint the screen and return to normal operation  but this may  take several minutes           4825       After a reset of the entry switch of an 8 switch mesh  one of the other switches was left  in the blue  no response  state though it could be accessed by Telnet  The refresh  button did not clear the problem  although rediscovering the fabric did  This is a very  intermittent problem        Support    Please feel free to contact your QLogic approved reseller or QLogic Technical Support at any  phase of integration for assistance  QLogic Technical Support can be reached by the following    methods     Web  http   www qlogic com support report_problem asp  Email  support qlogic com    Phone         952  932 4040       
4. SANbox Manager  Release Notes  Version 1 03 28    50208 06 Rev A    This software is licensed by QLogic for use by its customers only   Copyright  c  2001 QLogic Corporation  All rights reserved    Version 1 03 28 is a feature release of the QLogic SANbox     Manager Fabric Management  Application  SANbox2    version 1 3 25 and SANbox version 4 01 45 firmware  or greater  must be  used in conjunction with SANbox Manager     SANbox Manager does not support the legacy T_Port mode and therefore does not interface with  MKII switches or SANbox switches in T_ Port mode     Features in this Release    Version 1 03 28 provides the following features     e User Preferences     You can choose to configure the following options     O    Working directory     set the location for files to be saved  The default is the user   s  home directory    Browser location    location for the internet browser to be used to display on line  help    Polling frequency     how often SANbox Manager polls the switch for updated  information    View file auto save and load     enable or disable having the default fabric view file  automatically saved each time you exit SANbox Manager  The default is    enabled      Preferred initial port view    choose whether your default port view  in the faceplate  display  displays each port   s mode  state  speed or media  Any alternative view may  be selected from the faceplate display  Also  all information is listed in the Port Info  tab in the faceplate display r
5. ch  running 4 01 firmware with E_Port  are  described in the following manuals  These manuals are available only through QLogic Technical    Support   e SAN  e SAN   5903    e SAN    5903          box 8 16 with E Ports Switch Management Manual  Publication No  59033 00 Rev  A  box 8 with E_Ports Fibre Channel Switch Installer   s User   s Manual  Publication No    0 00 Rev  A   box 16STD with E_Ports Fibre Channel Switch Installer   s User   s Manual  Publication No   1 00 Rev  A    e SANbox 16HA with E_ Ports Fibre Channel Switch Installer   s User   s Manual  Publication No     5903    2 00 Rev  A    Issues Corrected in this Version       Problem  ID    Symptom       3601    Drag and drop of zone members in the Zoning window is not consistent on a Solaris  platform  If failure occurs  use the menu buttons instead        3610    Warning messages are displayed when installing on a Solaris platform  The messages  can be ignored  They include    Warning    Name  HorScrollba   Class  XmScrollba   The specified Scrollbar value is greater than the maximum   Scrollbar value minus the Scrollbar slider size       3649    Highlighting multiple members for zoning using the control button does not work  All  items are no longer highlighted when zone is selected        3904    There have been a few circumstances where the GUI becomes unresponsive to mouse  clicks  To recover from this  hold down the  lt ctrl gt  key while clicking on the left mouse  button           4057    Occasionally 
6. egardless of the port view displayed     e Archive restore chassis configuration to a file   If a switch must be replaced  you can  save the configuration information to a file  replace the switch and restore that configuration  information to the new switch  These options are found in the Switch menu in the faceplate  display     e Set beacon on switch     If you need to easily locate a specific switch  set the beacon on that  switch  This will cause the switch LEDs to blink  To set beacon  select    Toggle beacon     from the    Switch    menu     e Simple Broadcast Support     This feature allows for a frame to be broadcasted to the entire  fabric  including outside vendor switches  when those vendors support this functionality   Broadcast frames are not sent out to TL ports  To enable this feature  select    Switch  Properties    from the    Switch    menu and then enable    Broadcast support        e On line diagnostics support     The Port Loopback Test  available via the Port menu  now  supports internal  external and online port tests    o The internal test is a loopback test and can only be performed on a port that is ina  diagnostic state  The internal loopback tests all of the hardware on the port and may  be useful in situations where it is inconvenient to install a loopback plug in a port    o The external test is a loopback test and can only be performed on a port that is in a  diagnostic state and has a loopback plug installed  This tests all of the hardware on
7. font  path on the machine that is displaying SANbox Manager  not the machine on which  the application is executing   This can be done using the sdtfontadm utility  and must  be done as root    4417 The    Load Firmware    and    Edit Zoning    dialog boxes can become hidden behind the  main window and give the appearance that the GUI is hung    4533 Drag and drop from Zoning dialog to application window hangs the GUI  This is caused  by Sun Bug ID  4633417 and 4623377    4562 The port loopback test times out occasionally on a multi processor system    4692 When changing DomainID to a value greater than 31  a warning message is presented  telling you that the DomainID is invalid but the operation is allowed    4763 On Windows based PCs  on occasion the GUI will abort when entering the faceplate  display  Restarting the GUI will correct this problem  This bug is caused by Sun Bug  ID  4482430  4500800 and 4523926    4764 If an ISL goes down between a SANbox2 and McData switch  the ISL state is             sometimes not reflected until you click on Refresh        4765    If    set switch state    is used in CLIsh to set the switch offline  the GUI does not  recognize this state  This is because    set switch state    in CLIsh is a temporary setting   The GUI reflects the permanent setting set by    set config switch           4774    With a mixed SANbox 1Gb and SANbox2 switch configuration  if you add a fabric to  SANbox Manager by entering the IP address of a SANbox 1Gb switch
8. when you minimize the SANbox Manager application and then attempt  to maximize it  it will not come up  On a windows platform  bring up the Task  Manager  select SANbox Manager  select End Task and then restart the application  On  a UNIX platform  kill the SANbox Manager process              Known Installation and Packaging Issues                         Problem   Symptom   ID   4321 The uninstall script is located in the UninstallerData subdirectory instead of the main  installation directory    4324 If installing on a UNIX platform as root  you cannot install in the home directory    4392 After the installation is complete  the installer may tell the user to click    Done    to quit  the installer when the user really must click    Next    and then    Done       4466 On the  Install Complete  screen  if the user selects the  Previous  button  all other  buttons become inactive and the user is forced to make an un graceful exit  Note that at  this point  the GUI has already been installed    4467 When exiting the Installer  an  Install Not Complete  message is received that states            To cancel Install select  Quit   and     If you exit  the SANbox Manager will not be  installed      The installation is not cancelled and the SANbox Manager remains installed even if the   Quit  button is selected           Known Functionality Issues                                                    Problem   Symptom   ID   4250 When scrolling through the Trap log  the refresh of the 
9. window places the scroll  position at the bottom of the window  A work around would be to export the trap log  and view with an editor    4328 If you make a change  for example changing port state  that change may not be  instantaneous and no wait message or other indication is given    4338 SANbox Manager disappeared unexpectedly  leaving behind a core file in the install  directory  This is caused by Sun Bug ID  4641535  JDK 1 4 Solaris  memory leak when  remote displaying     The workaround is to define the environment variable JZEDFONTSCALER 12k before  running the GUI     export JEDFONTSCALER t2k    SANbox_ Manager   4340 After running for approximately 18 hours  SANbox Manager had an out of memory  exception error  This is caused by Sun Bug ID  4641535  JDK 1 4 Solaris  memory leak  when remote displaying     The workaround is to define the environment variable JZEDFONTSCALER 12k before  running the GUI     export JEDFONTSCALER t2k    SANbox_ Manager   4411 When launching SANbox Manager  you may receive an error regarding your font   settings  For example     Cannot convert string monotype arial regular       This is a configuration issue with X windows and does not affect the functionality of  the GUI  The font path of the machine whose X server is displaying the application  needs to have a directory which either has the specified font  Arial  or a font alias to  re map it to another font   For example  you might add the  usr openwin lib X11 TrueType directory to the 
    