1.  on the mounting position      Install your blades and or blanking panels  see Section 1 1 2   Connect the power cable to the rear of the unit s      Lift the now populated chassis and bracket assembly into the rack at the desired level  and  attach with rack screws  not provided      1 3 Hardware Inventory    1   2   3   4     AC power cord   DC power supply   Four rubber feet     RS 232 console cable     1 4 Blade Installation and Removal       Note  Itis important that the module be properly aligned with the slot guides before it is inserted  into the appropriate slot on the chassis  It is recommended that the user   s line of sight be  level with the middle of the backplane in order to see both slot guides clearly        Install a VSI blade into the chassis as follows        Caution  Use proper ESD precautions when installing or removing a VSI blade to avoid  damaging the unit   s circuitry        Slide the blade  open end first  into the desired slot on the chassis until it plugs into the  connector located on the backplane at the rear of the unit     To insure that the blade is properly seated in the chassis and mated to the rear connectors   push firmly on the blade s front panel  Ensure that the front panel face is flush with the  chassis ends and sides  Note the red and black handle on the blade does not mount or lock  to anything on the MPP200 chassis     Tighten the captive thumb screw located at the top of the blade to provide a more secure  mounting     If desire
2. MPP200 User   s Manual    Status 1 m     DCIN     o    aan  lt  la   amp  S  3 Status 2     Video 2    Visionary Solutions  Inc M P P    Video 1 m    IP Media Processing Platform         2011 Visionary Solutions  Inc  All rights reserved     Please visit the support section of our website at www vsicam com  for manuals  other documentation  and software downloads     Visionary Solutions  Inc   2060 Alameda Padre Serra  Suite 100   Santa Barbara  CA 93103  T 805 845 8900  F 805 845 8889  www vsicam com    July 10  2011  Revision 1 0 5    About This Guide    VSI recommends that you download the most recent version of this Manual from www vsicam com     Limited Liability   In no event shall Visionary Solutions  Inc  be liable  whether in contract  tort  or otherwise  to OEM or Customers for  a  any damages resulting from  loss of use  data or profits howsoever arising hereunder in relation to or in connection with Visionary Solutions  Inc  Software   b  any special  indirect   incidental or consequential damages  even if Visionary Solutions  Inc  has been advised of the possibility thereof  Visionary Solutions  Inc  s total  liability in contract  tort or otherwise arising out of  in connection with or in relation to the Software or otherwise under this Agreement shall be limited to  the amount paid to Visionary Solutions  Inc  or and authorized Visionary Solutions  Inc  reseller for the Visionary Solutions  Inc  Software or Hardware  for a Customer in the 12 month period immedi
3. ately preceding the event which has given rise to the liability    The contents of this document are subject to revision without notice due to continued progress in methodology  design  and manufacturing  Visionary  Solutions  Inc  shall have no liability for any error or damages of any kind resulting from the use of this document     Trademark Acknowledgements  All trademarks or registered trademarks are properties of their respective owners     Visionary Solutions  Inc   Limited 12 Month MPP200 Warranty    We appreciate your purchase of this Visionary Solutions  Inc  product  We feel confident that in normal use it will provide years of satisfactory  performance    Visionary Solutions  Inc  warrants to the original user that the video equipment supplied by us will be free of defects in materials and workmanship for  a period of twelve  12  months from the date of purchase from Visionary Solutions  Inc  or an authorized reseller of Visionary Solutions  Inc  Visionary  Solutions  Inc    s obligation under this warranty shall be to the repair including any necessary parts and the cost of labor connected therewith  or at its  option  the exchange or the refund of the purchase price  of any video equipment that is determined by us to have a manufacturing defect within the  warranty period    Replacement parts furnished in connection with this warranty shall be warranted for a period equal to the unexpired portion of the original equipment  warranty    Warranty Exclusions   This 
4. bligations    The original  dated  bill of sale should be retained as proof of purchase and must be presented to the Visionary Solutions  Inc  or a Visionary Solutions   Inc  Authorized Service Center when this equipment is to be serviced under the provisions of this warranty   The cost of transportation to and from the Authorized Service Center is the responsibility of the user     How to Obtain Warranty Service    Should this equipment require warranty service you may obtain specific information on how to obtain this service by directly contacting Visionary  Solutions  Inc   or the reseller who sold you this equipment           The MPP200 User   s Manual    1 1 The MPP200    The Media Processing Platform  MPP  200 is a high density  blade chassis used in VSI IPTV  applications  It can be rack mounted in a 1U space or used as a stand alone     Slots 1 and 2 on the chassis can be filled with any VSI blade product   1 1 1 MPP200 Front Panel Slots    Blade Slots       MPP200  lo                    T a 1 Visionary Solutions  Ine   O ellolfellelellellelleleleie  G   vsicam com  g  T O        amp                 1 1 2 MPP200 Rear Panel       Status 1 O  Video 1 0    Power O    sue  0 Gs MPP200         Vidao2 O Visionary Solutions  In IP Madia Processing Platform          Status 1     Copies the status LED pattern of the blade inserted into Slot 1  For more information  about the blade  refer to the VSI User s Manual for that blade     Video 1     Copies the video LED pattern of th
5. d  an additional Phillips screw can be installed through the handle     The Status LED will blink once a second when the blade is properly installed  powered  and  operational           To remove a VSI blade   1  Loosen the mounting screw at the top of the blade   2  If installed  loosen the additional Phillips screw in the ejector handle    3  To pull the blade out of its slot and away from the chassis  pull on the mounting screw at the  top of the blade and on the handle at the bottom     1 5 Installing Blanking Panels    After all blade options have been installed  all empty slots must be populated with blanking  panels  Install blanking panels as follows        Warning  Failure to populate empty slots with blanking panels will negatively effect  EMC radiation and immunity           Note  Blanking panels are used to cover each of the empty blade slots        1  Place the blanking panel onto the face of the MPP200     2  Tighten the two captive screws on the front of the blanking panel     1 6 MPP200 Safety and Compliance  Unit Ratings    A Caution  5Vdc  4A   Power Supply Rating    A Caution  100 250V   50 60 Hz  1 0A    Fuse Rating   No user accessible fuse     Safety Approvals     UL Listed I T E  E257717       
6. e blade inserted into Slot 1  For more information  about the blade  refer to the VSI User s Manual for that blade     Power     The Power LED illuminates green when power is supplied to the chassis           Status 2     Copies the status LED pattern of the blade inserted into Slot 2  For more information  about the blade  refer to the VSI User s Manual for that blade     Video 2     Copies the video LED pattern of the blade inserted into Slot 2  For more information  about the blade  refer to the VSI User s Manual for that blade     1 2 Rack Mounting the MPP200       Warning  Before installing the MPP200  be sure to read the safety and equipment  information contained in this chapter           Caution  Use proper electrostatic discharge  ESD  precautions when installing or removing  the MPP200 to avoid damaging the unit   s circuitry        The MPP200 is designed to be rack mountable  It is 5 7 inches wide and utilizes 1U of rack  space when mounted  Refer to the sections that follow for information on installing blades and  blanking panels     In order to install the MPP200 on a rack  you will need an MPP200 Rack Mount Kit and a Phillips  screwdriver  The kit includes 2 small brackets  1 medium length bracket  1 long bracket  and   10 screws  The MPP200 Rack Mount Kit can mount one or two MPP200s in a 1U space  and can  be purchased online at www vsicam com     1  Locate and remove two pairs of screws from the chassis  depending upon the desired final  position of the chas
7. sis in the rack  front or back      For example  to mount the chassis in the rack with the front facing out  remove the pairs of  screws  left and right  closest to the front of the chassis  leaving the middle and back screws  in place     2  Install one MPP200 chassis  you will need one small bracket  the long bracket  and four  screws from the MPP200 Rack Mount Kit     a  On the side of the chassis that is to be next to the rack sidewall  attach one of the small  brackets  using the smaller holes on the bracket and the empty screw holes on the  chassis  Make sure that the larger holes on the bracket are flush with the face of the  chassis     b  Attach the long bracket to the other side of chassis so that the longest face of the bracket  is flush with the chassis  front or back depending on the mounting position      3  Install two MPP200 chassis  you will need two small brackets  the medium bracket  and  eight screws from the MPP200 Rack Mount Kit     a  Attach a small bracket to each chassis so that the brackets are attached on opposite  sides  e g   so that one chassis has a bracket on the left side and the other has a bracket  on the right side   using the smaller holes on the bracket and the empty screw holes on  the chassis  Make sure that the larger holes on the brackets are flush with the face of the  chassis           b  Attach the medium bracket between the two chassis so that the longest bracket face is  flush with the face of the chassis  front or back depending
8. warranty does not apply to repairs or replacements necessitated by any cause beyond the control of Visionary Solutions  Inc   including  but not  limited to  acts of nature  improper installation  misuse  lack of proper maintenance  accident  voltage fluctuations  and unauthorized repairs or  modifications    This warranty becomes void in the event serial numbers are altered  defaced  or removed    Visionary Solutions  Inc  reserves the right to make changes in the design  or make additions to  or improvements upon  this product without incurring  obligations to install the same on products previously manufactured    The foregoing warranty is in lieu of all other warranties  expressed or implied  including  but not limited to  the implied warranties of merchantability and  fitness for a particular purpose  Visionary Solutions  Inc  neither assumes nor authorizes any person to assume for it any other obligations or liabilities  in connection with the sale of its products  In no event shall Visionary Solutions  Inc  or its authorized resellers be liable for special or consequential  damages arising from the use of its products  or any delay in the performance of this warranty due to causes beyond its control    IN THE U S A   SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS AND OR THE EXCLUSION OR  LIMITATION OF CONSEQUENTIAL DAMAGES  SO THE PREVIOUSLY STATED LIMITATIONS ON IMPLIED WARRANTY AND  CONSEQUENTIAL DAMAGES MAY NOT APPLY TO YOU     Customer O
    
Download Pdf Manuals
 
 
    
Related Search
 (MPP200_Users_Manual) 
    
Related Contents
Philips SPP3160C  PDFファイル    MYOB Accounting v16 and Accounting Plus v16: User Guide  MANUAL DE INSTRUCCIONES LAVADORA DE ROPAS  Hoover Commercial Windtunnel C1705  MOTM-190 User Manual - Synthesis Technology  Experiencias de creación de objetos de aprendizaje en dominios    Expandable and remote controlled Burglar alarm control panel Cod    Copyright © All rights reserved. 