User manual SETHDIN
Contents
1. the conversion that one wants execute it is necessary to configure the DIP SWITCHES in the following way FOR R 232RS485 AND ETHERNET gt RS485 CONVERSION 2 3 4 ON FOR RS232 RS422 AND E ETHERNET RS422 CONVERSION 2 3 4 OFF For RS232 ETHERNET convention the configuration of DIP SWITCH is irrelevant VER 02 00 03 0046 SETHDIN 13 03 EN 9 RESET OF MODULE To reset the module and return at initial settings is necessary do the following operations switch off the instrument open the tool so as to be able to close the jumper J2 close the jumper J2 Switch on the tool now the 2 cpu card LEDs red and green flash repeatedly to complete the reset open the jumper and restart the instrument
2. 1 of one module with the Port 1 of the other one or vice versa To activate this modality is enough to set the UDP Remote IP Address parameter at the same value so the address of the other module for both serial ports Set this address to 0 0 0 0 to disable the tunneling function over the relative serial port 02 00 03 0046 SETHDIN 13 03 3 4 GENERAL SETTINGS The Miscellaneous Settings page allows to set some general parameters of the SETHDIN module mostly concerning its function mode and connections to the network Miscellaneous Settings Port 0 RS232 min Ere 02 00 03 0046D Settings EVEN 155 168 16 205 Port 1 RS485 422 50 0 50 c2 ab 71 da Settings Miscellaneous Settings IP Address Selection Setting 5 Static IP Sees 192 165 16 205 255 255 255 0 Default Gateway fi 0 0 0 General Configuration Settings VRSTIESUEIEM SETH DIN Serial 2 Ethernet UPnP port number 6432 Web Server Port Number zi IRE Serial Ethernet Restore Factory Defaults Restore all options to their factory default The pages Port0 RS232 Settings and Port1 RS485 422 Settings allow to set the communications parameters of the ports 232 and 485 422 VER 02 00 03 0046 SETHDIN 13 03 EN 4 SETHDIN 4 1 SERIAL TO ETHERNET To set this function mode is necessary do Select the page Miscellaneous
3. BRX B 1 10 TX A 2 11 TX A 2 DIP SWITCH 7 234 OFF 8 1 RS 232 CONNECTION PC 9 pin SETHDIN STANDARD CABLE male RS232 gt P o px mo pe Do sew 9 2 RS 485 CONNECTION Below is the RS485 connection of the module Modue Serial line TX RX 8 A TX RX 9 B On the same RS 485 line it s possibile to connect up to 32 devices 13 VER 02 00 03 0046 SETHDIN 13 03 EN Disp 1 Disp 2 X Dx Disp n Figure 1 electrical diagram of RS485 connections UseaSTP Shielded Twisted Pair cable in order to make the connection twisted and shielded pair s with single shielding for each pair through aluminium band and total shielding through external sheathing The maximum reachable length from the line with the use of the appropriate cable for RS 485 connections the twisted 2x24 AWG duplex cable shielded with external sheathing aluminium band is of about 1200 meters see section 1 1 3 With very long cables the cable capacity normally near 50pF m starts being a dominant factor in the power consumption and increases with the increase of speed This implies that the maximum distance can t be covered with the maximum possible speed For an approximate value one can consult the following table Baud rate Total capacity of the cable pF 1200 2400 4800 As a general rule if one has any doubts it is always preferable to choose the cable with a greater section On the RS485 network normall
4. OPERATIVE MANUAL SETHDIN SETHNET SETHDIN SETHNET C232485 13 03 EN VER 02 00 03 0046 SETHDIN 13 03 EN INDEX Al INTRODUCTION 3 2 IDENTIFICATION OF THE DEVICE ON THE NETWORK ttt 3 3 PARAMETERS CONFIGURATION THROUGH WEB 5 4 3 1 STATUS AND CONFIGURATION Home page 4 3 2 SETTING OF THE PROTECTION 8 annann nn 5 3 3 TUNNELING FUNCTIONING MODE iiie 5 3 3 4 DOUBLE TUNNELING 5 3 4 GENERAL 6 ec Gee aaa 7 TO EE NED 7 4 2 MODBUS TCP ETHERNET CONVERSION 8 4 3 SETH BROADCAST FUNCTION MODE ttc 9 4 3 SETH BROADCAST FUNCTION MODE 9 56232405 10 5 1 RS432 gt RS485 422 CONVERSION 10 11 6 1 NETWORK ADAPTER FUNCTION MODE 11 7 MAIN TECHNICAL 12 8 SETHDIN CONNECTIONS ctam etsium d DM MALUM D MALE UD ALD D 13 CONNEC TON ees te
5. Settings Change the parameter Operating Mode in Serial To Ethernet Click on Save and Reboot to save the configuration and restart the module In this function mode you can choose the following conversions RS232 ETHERNET R8485 5 ETHERNET R8422 ETHERNET As follow its will be necessary set the DIP SWITCH present on the board to perform the various conversions see cap 8 3 DIP SWITCH Miscellaneous Settings Port 0 R5232 aims 02 00 03 00460 SEDES EVITE 192 168 16 205 Port 1 RS485 422 Eee nrw 00 50 c2 ab 71 da Settings Reboot Miscellaneous Settings IP Address Selection Password Setting Static IP T Seen 192 168 16 205 SIM 255 0 255 255 0 Default Gateway 0 0 o General Configuration Settings eee ene SETH DIN Seral 2 Ethernet UPnP port number 6432 Web Server Port Number E0 Seral Ethernet Restore Factory Defaults Restore all options to their factory default When you change the function mode of module the browser will show a message window where you can see the parameters that had been changed Messaggio dalla pagina Web 25 ih MODBUS TCP mode will set both serial ports to 9600 8 2 with no flow control Modbus RTU on both serial ports TCP local ports to 502 and 503 Press SAVE and REBOOT to commit new operating mode VER 02 00 03 0046 SETHDIN 13 03 EN 4 2 MODBUS gt ETHERNET CONVERSION
6. The SETHDIN module permits to do the conversions MODBUS TCP ETHERNET To set the module Select the page the Miscellaneous Settings Change the parameter Operating Mode in MODBUS TCP Click on Save and Reboot to save the configuration and restart the module Miscellaneous Settings Home SETH DIN Serial 2 Ethernet Port 0 R5232 mini ruat 02 00 03 0046D mx EVITE 15 168 16 205 Port 1 RS485 422 utim 00 50 c2 ab 71 da Settings Miscellaneous Settings IP Address Selection Password Setting SusclP 192 168 16 205 Smee 255 255 255 0 Default Gateway 10 o General Configuration Settings SETHDIN Serial 2 Echemne UPnP port 632 Web Server Port Number 20 Operating Mode Momem M Restore Factory Defaults Restore all options to their factory default The function mode MODBUS TCP requires a network connection that uses the TCP IP protocols In order to establish a communication using the Modbus protocol is sufficient connect the module on RS232 485 to tool that supports the Modbus RTU or Modbus ASCII VER 02 00 03 0046 SETHDIN 13 03 EN 4 3 SETH BROADCAST FUNCTION MODE It is possible set the function mode BROADCAST on module This configuration allows to have a module MASTER that sends the data to N modules setted on the same UDP port PRINTER 1 REMOTE DISPLAY fetececoe ETC J ee S232 RS485 RS422 In this type of app
7. e eie E mM ance E E EE 13 D 5 ONNEE TION E N E 13 cech UE MEME cease cece 15 ORE SEF Ol MODULE sensors MU a 16 VER 02 00 03 0046 SETHDIN 13 03 EN 1 INTRODUCTION Allows the following conversions RS232 lt ETHERNET RS485 lt ETHERNET SETHDIN R8422 ETHERNET 5232 5485 5232 RS422 MODBUS TCP 5SETHERNET SETHNET Allows to share the archives between 2 3590E EGT AF03 C232485 It serial converter that allows you to convert RS232 RS485 2 IDENTIFICATION OF THE DEVICE ON THE NETWORK The SETH module increase uses the technology UPnP Universal Plug and Play which allows to use a device when it connects at the network This means that when they are connected at the network the SETHDIN devices should automatically appear on the Windows Network Resources where it will also shows the IP address associated from the DHCP server or the configured fixed address The SETHDIN module has the default address 192 168 16 205 the default password Password To establish a communication with a computer or any other device connected at the network it is necessary that the module belongs to the same class of network in our case the network should have the addresses of this type 192 168 16 xxx otherwise must assign to SETHDIN an IP address that belongs to the class of network or device to which you connect The steps required to perform these operation
8. e technical manual of E AF03 11 VER 02 00 03 0046 SETHDIN 13 03 EN 7 MAIN TECHNICAL SPECIFICATIONS POWER SUPPLY SETHDIN 8 36 232485 BOX 12 with internal 100 240 Vac 50 60 Hz 12 adapter MAX ABSORPTION 200 mA 5W at 24Vdc OPERATING TEMPERATURE 10 C 50 C CASE SETHDIN In plastic suitable for mounting on DIN bar or on the wall C232485 BOX in ABS with IP 67 protection Ethernet interface PROTOCOLS TCP UDP DHCP SNMP SSL 3 0 TLS 1 0 HTTP SMTP ICMP IGMP CONNECTION Through RJ45 standard connector WEB INTERFACE 10 100 Base T SPEED COMMUNICATION 10 100Mbps Available conversions RS232 ETHERNET RS485 ETHERNET RS422 lt ETHERNET RS232 RS485 RS232 RS422 LED meaning GREEN LED YELLOW LED GREN YELLOW SOME CONSECUTIVE Atthe start up indicates that the module is ON BLINKINGS When the module is on indicates the presence of serial activities Newokcbienocomeded SO FIXED Device connected at the network BLINKING a Presence of network activity VER 02 00 03 0046 8 SETHDIN CONNECTIONS POWER SUPPLY 1 Vdc 2 GND 6 EARTH Earth 8Vdc 36Vdc GND SETHDIN_13 03_EN 3 4 5 6 7 8 9 40 11 SERIALS TX RX GND EARTH SHD BRX TX TX RS232 3 TXD TX 4 RXD RX 5 GND GND RS485 SETHDIN 7 SHD Shield Mu T ET DINI ARGED 9 BRX B DIP SWITCH 2 3 4 ON POWER RS422 8 36Vdc 7 SHD Shield 8 ARX A 1 9
9. estore Factory Defaults Restore Defaults and Reboot Restore all options to their factory default These are the standard parameters of 232485 converter that allow the convertions RS232 gt RS485 default configuration of DIP SWITCH RS232 gt RS422 Then it will be necessary to configure the DIP SWITCHES of the board to make the conversion see the chapter 8 3 DIP SWITCH 10 VER 02 00 03 0046 SETHDIN 13 03 EN 6 SETHNET 6 1 NETWORK ADAPTER FUNCTION MODE To set this function mode Change the parameter Operating Mode in Network Adapter Click on Save and Reboot to save the configuration and restart the module Miscellaneous Settings Home SETH DIN Serial 2 Ethernet Port 0 05232 mium ueri 02 00 03 00460 means DEVE 15 168 16 205 Port 1 RS485 422 tutiw 00 50 c2 ab 71 da Settings Miscellaneous Settings IP Address Selection Password Setting 55 Static IP 192 168 16 205 Sa Ew 255 0 255 2355 0 Default Gateway 0 0 0 General Configuration Settings FIIESUEINISM SETH DIN Serial 2 Ethernet UPnP port number 5432 Web Server Port Number Operating Mode Restore Factory Defaults Restore all options to their factory default This function mode currently is adapted only to DiniArgeo indicators This function premise to share the archives between 2 3590E EGT AF03 indicators for more information see th
10. lication in addition to setting the same UDP port of MASTER on all modules that must receive the data it is necessary set 255 255 255 255 as broadcast address on MASTER UDP Settings Current Updated Local UDP Port Number 2001 3001 Remote UDP Port Number 3001 3001 10 decimal ASCII code 10 char 0 for no trigger char WB MEC ds 100 milliseconds 100 milliseconds iis for no timeout UDP Remote ESSERE 0 0 0 0 25 F Make these settings permanent VER 02 00 03 0046 SETHDIN 13 03 EN 9 C232485 5 1 R8432 gt RS485 422 CONVERSION SETHDIN allows to make a conversion from RS232 to RS485 RS422 by avoiding the Ethernet connection To configure the module Select the Miscellaneous Settings page Change the Operating Mode in Serial Bridge item like marked in figure Click on Save and Reboot to save the configuration and restart the module Miscellaneous Settings Home SETH Serial2Ethernet Module Port 0 RS232 aiu 01 02 01 0027 Settings SEWER 102 168 16205 Port 1 RS485 422 eue eli 00 50 2 0 9 Settings Miscellaneous IP Address Selection Settings 55 Static IP 5 192 168 16 205 STORM 255 255 o Default Gateway le Save and Reboot General Configuration Settings Module Name UPnP port number Web Save and Reboot R
11. s by the computer are Assigned to the PC an IP address that belongs to the class of the module standard 192 168 16 xxx Connect the module to the computer through ethernet cable Enter the home page of module and assign a free IP address that belongs to the class of network when will be used VER 02 00 03 0046 SETHDIN 13 03 EN 3 PARAMETERS CONFIGURATION THROUGH WEB SERVER 3 1 STATUS AND CONFIGURATION Home page By making double click on the SETHDIN module listed on the Network Resources or digit the IP address on the address bar of your browser see below example A ed Jc N 19216816 D 2X the home page of the web server will appears on the default browser which will shows the status and the configuration of the module Status amp Configuration Home SETH DIN Serial 2 Ethernet Port 0 RS232 EN 02000300460 Port 1 RS485 422 00 50 c2 ab 71 da Settings Password Current port settings Setting Port 0 RS232 Port 1 RS485 422 9600 bits second 9600 bits second 8 bits character 8 bits character None None 1bit s 1bit s None None 3001 3002 3001 3002 10 decimal ASCII 10 decimal ASCII 100 ms 100 ms 0 0 0 0 0 0 0 0 23 26 Server Server N A N A 0s 0s RTU RTU VER 02 00 03 0046 SETHDIN 13 03 EN 3 2 SETTING OF THE PROTECTION PASSWORD It s possible to protect the device configuration from writing and reading through a password Choose the Password Setting option from the menu Type
12. two times the desidered password and click on Submit and it will be permanently memorized from the module If the two boxes are empty the password protection will be disabled After which to access at the home page it will necessary to insert the correct password and click on Enter Enter Password If the inserted password is wrong the same page appear 3 3 TUNNELING FUNCTIONING MODE The tunneling mode allows to turn away a device for example a repeater or a printer connected at the instrument everywhere there is an node of the Ethernet network In this way one can easily overcome the limits of the typical serial connections Of course one needs two SETHDIN modules one to be connect at the serial of the instrument and the other one at the serial port of the device Over every module one has to configure the UDP Remote IP Address and UDP Remote Port parameter who indicates the input data destination over the serial with the IP address and the UDP local port of the other module Example P MODULE 1 MODULE 2 IP address 192 168 16 205 192 168 16 204 UDP Remote IP Address 192 168 16 204 192 168 16 205 UDP Remote Port 3001 3001 3 3 1 DOUBLE TUNNELING The SETH can manage two tunneling processes simultaneously one for every serial port Two virtual connections will be created one for the Port 0 of the modules and the other one for the Port 7 This association is fixed so it is not possible to connect the Port
13. y one connects 2 termination resistances equal to the characteristic impedance of the cable tipically 120 O see Figure 1 ONLY on the 2 devices which are at the 2 ends of the ring connection The difference of potential between the A and B terminals in rest conditions for example with instrument in set up phase must be of at least 0 2 V To create a resistive divider which maintains this difference of potential also when all the transmitters are disabled inert in the RS485 port of the indicator where there are the termination resistances the polarisation or fail safe resistences Figure 1 The value of these resistances is between 390 and 2 2 ncase of connection with non Dini Argeo devices there may be different ways of line marking generally one presumes that the A B indication corresponds to the and HI LO markings but this is not always true Therefore if the device does not function one should try inverting the connections even if everything seems to be correct 14 VER 02 00 03 0046 SETHDIN 13 03 EN 8 3 DIP SWITCH For the connection 5485 and 5422 it s necessary to configure the DIP SWITCHES of the board with the module so that to address the data on the desidered port 1234 The DIP SWITCH 1 is used to enable the terminal resistance of 1200 RT to be used only for RS485 comunication DIP SWITCH FOR RS232 RS485 422 ETHERNET RS485 422 ETHERNET RS232 CONVERTION Depending on