Home
User Guide - Nexia Home Intelligence
Contents
1. User Settings User Settings allow the user to customize various settings on the 624 control To access User Settings simply press the Menu button once and User Settings will be displayed To enter the User Settings menu press the Select button then use the Next button to navigate through the options below The default setting will be shown in brackets After each selection press the Done button to save changes Thermostat Setting Range Description Temperature Scale Cooling RH Setpoint Fahrenheit Celsius Select the temperature display scale Select the desired indoor relative humidity during cooling mode Dehu 30 60 50 midification must be enabled in the Installer Settings for this option to be available Smart Continuous Fan Yes No If yes is selected continuous fan mode is disabled when indoor humidity exceeds the Cooling RH Setpoint Continuous Fan Airflow 35 100 50 Select the desired fan speed when the Fan Mode selected is Continuous variable speed blower required Fan Circulate On Time 1 59 minutes Off Select the desired amount of time the fan will cycle per hour when the Fan Mode selected is Circ Local Schedule Enable Yes No Select whether scheduling will be enabled or disabled Max Heat Setpoint 55 90 Degrees Select the highest heating setpoint allowed Min Cooling Setpoint 60 99 Degrees Select
2. COPY _ _ To is displayed at the top of the screen Yes and No buttons are displayed on the right side of the screen Pressing Yes will copy the day displayed to the next day in the week If Yes is pressed five more times the scheduled will be copied to the remaining 5 days in the week To skip over a day and avoid copying the schedule to that day press No Press Done EDIT SCHEDULE To return to the Home Screen press Done one more time menu is displayed Press Done Home Screen is displayed The schedule may be changed locally at the control with the Edit Schedule menu If the 624 comfort control is connected to Nexia Home Intelligence the schedule may be changed remotely from the Nexia website using the websites Edit Schedule menu User Guide Scheduling Copying Schedules Press the following button sequence to access Copying Schedules from the Home Screen Copying Schedules Button Press Menu Displayed What Needs to Be Done Menu Next USER SETTINGS screen Select EDIT SCHEDULE screen Next COPY SCHEDULE screen Select COPY FROM screen Mon Defaults to Monday Next Advances to next day Back Goes back to previous day Select Copy To screen Select the day to copy to by pressing on Yes or No buttons until the copy to day is selected Press Done COPY SCHEDULE Continue copying one days schedule at a time to another or Press
3. a On the Edit Home Firrmware Updates page the 624 will appear If a firmware update is available an Update Firmware button will appear Welcome mkateley Logout View Home QA2 Home Edit Home HOME INTELLIGENCE Dashboard Automation Event History My Alerts My Account Viewing QA2 Home June 11 2013 10 15am EDT Location 80211 Show Photo Edit Home PTERA Home Information Y Advanced a SENSORS t5 7 L Bridge Firmware VIDEO Firmware Version 001 027 003 lt Z Wave Version 2 78 LIGHTING amp zafi 5 Device Firmware G MODULES oe AmStd 624 6 39 4 CLIMATE Firmware Version 0 5 Update Firmware E 2012 Schlage Privacy Policy Terms and Conditions Subscriber Community Where to Buy Contact Nexia Help E 10 User Guide b connect to the device and then it will display the firmware update progress When the user selects the Update Firmware button an Update Firmware dialog will appear The dialog will first Update Firmware y Connecting to device n Firmware update 0 complete Estimated time remaining 45 minutes After the firmware has been downloaded it is then applied to the TCONT624 Update Firmware y Connecting to device y Firmware update 100 complete Estimated time remaining 0 minutes 3 Applying new firmware version to device This process will take
4. about 90 seconds corcel a d The portal retrieves version information from the TCONT624 a Update Firmware v Connecting to device y Firmware update 100 complete Estimated time remaining 0 minutes Applying new firmware version to device This process will take about 90 seconds 3e Retrieving new version information Cancel x e Finally the user is shown that the firmware was updated successfully Update Firmware Connecting to device y Firmware update 100 complete Estimated time remaining 0 minutes x Applying new firmware version to device This process will take about 90 seconds o Retrieving new version information J Firmware update successful OK k About About Setting Range Version Current firmware version loaded on the control ZWAVE Ver Current version of the ZWAVE firmware Node ID ZWAVE identification for this device Home ID ZWAVE identification for the connected ZWAVE network Out Type Identifies the type of outdoor unit installed C O Type Indicates whether the switchover valve SOV is energized in cooling or heating mode In Type Identifies the type of indoor unit installed Once all selections have been made press the Done button to exit and return to Menu Press Next to navigate to the next setting Clean Screen Clean Screen Setting Range Description Clean Screen Yes No chemicals Selecting yes allows the user to clean the scr
5. policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice
6. unless otherwise specified Increased utility usage costs REFRIGERANT POLICY 1 Manufacturer Installed Refrigerant Beginning on January 1 2010 R 22 refrigerant will no longer be used as a manufacturer installed refrigerant as required by federal regulation All Products with manufacturer installed refrigerant will include R 410A refrigerant Any and all expenses or costs associated with replacing Product parts that are not R 410A compatible will not be covered by the terms and conditions of this limited warranty 2 Non Manufacturer installed Refrigerant For Products manufactured and sold by the Company without refrigerant only manufacturer approved and genuine alternate refrigerants shall be used The use of contaminated counterfeit non genuine or non manufacturer approved alternate refrigerant will void this limited warranty 3 All Products Products include a liquid line filter drier which must be replaced when a compressor replacement is necessary A suction line filter drier must be added for compressors defined as burnouts and failure to do so will void this warranty Non approved refrigerant and or non approved refrigerant system additives including but not limited to dyes will void this limited warranty GW 658 2213 Warranty ADDITIONAL TERMS THIS LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES WHETHER IN CONTRACT OR IN NEGLIGENCE EXPRESS OR IMPLIED IN LAW OR IN F
7. 32 5088 01 Touchscreen S PANE Comfort Control 4 E Model TCONT624AS42DA N E X lA User Guide HOME INTELLIGENCE Nexia Home Intelligence Customer Service 877 288 7707 For HVAC related issues contact your servicing dealer NOTE A 24 Volt common and hot wire MUST be connected to the TCONT624A for operation Contents User Guide Feal S esnie n E S ANO 2 Operati aran a a E a a i a a E E 3 User SEUNG Sis s a A E T O S S 4 Schedules ne AA N Mhemmtade susansiaseucbadten Se dasmmeadecnadieae 5 Enrolling into Z Wave Network Nexia Home Intelligence ceccceecceeeceeeseeceeeeeeeeeaeeceaeeesaeseaeeseeeeseeseseeseesereeenee 8 Un enroll comfort control from existing Z Wave Network Nexia Home Intelligence ccccceeeeeeeeetetteteeeeeeees 9 Firmware Upgrades aeisi a EES EO EE a S E een adds 10 POUL ninae seca oa A E S OS 11 CEAN SOOO au Eana O E O R 11 Limited Wamran esaa a AN a Aa G 12 FOCHC NOICS asrnane anian a E EE eins ase a a a a oai 14 User Guide Features TCONT624AS42DA Features 24v Z Wave comfort control Remote access via smart phone tablet or P C requires SK101 and a Nexia Home Intelligence account Interactive 4 3 black amp white touchscreen 7 Day programmable 4 schedules day Built in humidity sensor with RH display Filter maintenance humidifier service reminders Remote temper
8. ACT THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE APPLICABLE PRODUCT WARRANTY COMPANY DOES NOT AUTHORIZE ANY PERSON TO CREATE FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE PRODUCTS NOTWITHSTANDING ANYTHING IN THIS LIMITED WARRANTY TO THE CONTRARY COMPANY SHALL NOT BE LIABLE FOR ANY INCIDENTAL CONSE QUENTIAL INDIRECT SPECIAL AND OR PUNITIVE DAMAGES WHETHER BASED ON CONTRACT WARRANTY TORT INCLUDING BUT NOT LIMITED TO STRICT LIABILITY OR NEGLIGENCE PATENT INFRINGEMENT OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES COMPANY S MAXIMUM LIABILITY HEREUNDER IS LIMITED TO THE ORIGINAL PURCHASE PRICE OF THE PRODUCTS No action arising out of any claimed breach of this limited warranty may be brought by a Purchaser more than one 1 year after the cause of action has arisen This limited warranty gives you specific legal rights and you may also have other rights as otherwise permitted by law If this Product is considered a consumer prod uct please be advised that some local laws do not allow limitations on incidental or consequential damages how long a warranty lasts based on registration or how long an implied warranty lasts so that the above limitations may not fully apply Refer to your local laws for your specific rights under this limited warranty Consumer Relations 20 Corporate Woods Dr Bridgeton MO 63044 Or visit our website at w
9. Done until the Home Screen Appears Press Done SCHEDULE Press Done HOME SCREEN is dis played Press Done Home Screen is displayed The schedule may be changed locally at the control with the Edit Schedule menu If the 624 comfort control is connected to Nexia Home Intelligence the schedule may be changed remotely from the Nexia website using the websites Edit Schedule menu Edit Schedule Remotely from Nexia Home Intelligence Go to MyNexia com log into your account and select a TCONT624 comfort control from the Climate Page Click on Edit Schedule and follow the online instructions If you have not set up a Nexia Home Intelligence account go to MyNexia com and click on Get Started to set up an account Arouter and Nexia Bridge kit SK101 includes one Nexia Bridge and one Z wave module is required for remote access to the 624 control For questions about connecting to Nexia Home Intelligence contact Nexia Home Intelligence Customer Service at 877 288 7707 User Guide Enroll Comfort Control into existing Z Wave Network Nexia Home Intelligence Prepare the bridge for enrollment Bridge kit SK101 purchased separately gt Note If the bridge is already installed follow the instructions as they are written in the following steps If the bridge is not installed follow the instruc tions shipped with the bridge kit Blue a Unplug Ethernet and power cables from bridge liah
10. ature sensing option 1 indoor 1 outdoor Auxiliary amp compressor heat lockouts Dehumidification overcooling Enhanced dehumidification cooling Adjustable variable speed fan settings pwm Energy Savings Mode ESM Screen lock and guest lock Upgradable firmware requires a Nexia Home Intelligence account Service test modes User Guide Operation The model TCONT624AS42DAA Comfort Control provides typical operation of a forced air heating and cooling HVAC system The TCONT624 comfort control also features a Z Wave module for remote control ieeLitiem GUTSIGE 6G jo cy B L F Cooling Te LV Hold Cool Auto Menu Sched Mode Fan GS TRANE Normally the Comfort Control displays the Home Screen as shown above Description Notes O_O Item Clock Display Dynamic Labels and Func tion Control Buttons Setpoint Display and Set point Up Down Buttons Temperature Display Menu Button System Mode Button Fan Mode Button Schedule Mode Button The current time is displayed in the upper left corner of the main screen The time will blink when the clock has not been set The buttons are defined by the dynamic labels in each button As you navigate through menus the labels for the buttons will change The current heat or cool setpoint is displayed These setpoints may be set using Nexia Home Intelligence the Control s i
11. b Install a quality 9 volt battery ight c Verify that blue light is blinking If blue light is solid battery is dead d Take bridge to the location where the Comfort Control is mounted Battery Enroll the Comfort Control into the bridge Inclusion If you are using a controller that is not a Nexia bridge consult the instructions that shipped with the controller to find out how to enroll a new device a Hold the bridge within 6 feet 1 8 meters of the Comfort Control throughout steps b through f ee Duron gt After you begin the enrollment process you have 30 seconds to complete the remainder of the steps Study the steps below before beginning K Press and release the plus button on the bridge Press the MENU button on the Comfort Control Press the NEXT button to advance to the Z WAVE menu Press SELECT Observe the lights on the bridge The orange light will blink while enrollment is taking place Enrollment is complete when the orange light becomes solid pao Verify enrollment of the Comfort Control a Press Menu Button on the main Comfort Control screen b Press the Next Button to advance to the About screen and press the Select Button c Press the Next Button to advance through the menu options to Node ID e If the number listed there is anything other than 00 the Comfort Control has been successfully enrolled Ifthe number listed there is 00 the Comfo
12. correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment IC Notice IC 9374A XR624 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement LY Ingersoll Rand 2013 Trane Residential Solutions Literature Order Number 32 5088 01 File number 32 5088 01 Supersedes New Trane 6200 Troup Highway Tyler TX 75707 Date 07 13 www trane com Trane has a
13. de Scheduling Edit Schedule Local Press the following button sequence to edit or create an entirely new daily schedule Edit Schedule Button Press Menu Displayed What Needs to Be Done Press Menu from Home screen USER SETTINGS Press Next SCHEDULE Press Select EDIT SCHEDULE Press Select SELECT DAY Continue to press Next until the day of week to edit is displayed Press Select SET TIME Set the start time for each of four periods for the day displayed Use the Up Down buttons to set the start time for the period displayed Wake is the default period Pressing the Next button three times cycles through the period displayed Wake Day Evening and Night Press Next HEAT SETPOINT Use the Up Down arrows to set the Heat set point for the period displayed Press Next COOL SETPOINT Use the Up Down arrows to set the Heat set point for the period displayed Press Next Continue pressing Next and using up down arrows until all Heat amp Cool set points are set for the day displayed After editing a start time or editing the set point temperature for one or more periods press Done to save edits If Done is not pressed edits will not be saved After Pressing Done Copy Schedule is dis played at the top of the screen Yes and No buttons are dis played on the right side of the screen Press yes to copy or no to return to Edit Schedule menu Press Yes to Copy
14. een without activating any of the onscreen touch points Use only water and a soft cloth no harmful Once all selections have been made press the Done button to exit and return to Menu Press Next to navigate to the next setting 11 Warranty 12 Base Limited Warranty Subject to the terms and conditions of this limited warranty Trane U S Inc Company extends a limited warranty against manufacturing defects for the product s identified in Tables 1 1A 1B attached hereto Products that are installed in a residential multi family application personal family or household purposes under normal use and maintenance in the United States and Canada This limited warranty applies to Products manufactured on or after August 1 2011 In order to maximize the available benefits under this limited warranty the Purchaser as defined below should read it in its entirety All repairs of Product parts covered under this limited warranty must be made with authorized service parts and by a licensed HVAC service provider Additionally commercial applications are treated differently under this limited warranty as stated in Tables 1 1A 1B attached hereto For purposes of this limited warranty commercial applications shall mean any ap plication other than for personal family or household use TERM The limited warranty period for Products is as stated in Tables 1 1A 1B attached hereto If the Purchaser pr
15. eturn to Menu Press Next to navigate to the next setting Reminders Setting Range Description Filtration Enable Yes No Selecting yes enables the Filter Reminder feature Filter Period Monthly Quarterly Semi Annu Select how often the reminder will be displayed ally Annually Filter Start Month Jan Dec Select the Filter Reminder start month System Maint Enable Yes No Selecting yes enables the System Maintenance Reminder feature First Maint Month Jan Dec Select the first System Maintenance month Second Maint Month Jan Dec Select the second System Maintenance month Once all selections have been made press the Done button to exit and return to Menu Press Next to navigate to the next setting Scheduling Schedule Setup Procedure The 624 comfort control is preset at the factory with a 7 Day energy savings schedule Each day of the week is pre programmed with the following schedule Scheduling Time Schedule Name Heat Temperature Setting Cool Temperature Setting 6 00 AM Wake 70 F 78 F 8 00 AM Day 62 F 85 F 6 00 PM Evening 70 F 78 F 10 00 PM Night 62 F 78 F The schedule may be changed locally at the control with the Edit Schedule menu If the 624 comfort control is connected to Nexia Home Intelligence the schedule may be changed remotely from the Nexia website using the website s Edit Schedule menu User Gui
16. gistered Limited Warranty Period ten 10 years AIR CLEANERS TFD amp AFD Base Limited Warranty Period five 5 years Registered Limited Warranty Period ten 10 years VARIABLE SPEED OIL FURNACE HV V LF V LR V DF V Base Limited Warranty Period Parts five 5 years Heat Exchanger twenty 20 years Registered Limited Warranty Period Parts ten 10 years Heat Exchanger Lifetime GW 658 2213 13 FCC Notice FCC ID WIBTZW012 INFORMATION TO USER This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to
17. ings e Display Lock Disables selection of all menus and settings e Guest Access Disables selection of all menus and settings except the following Raise or lower heating or cooling setpoint 5 degrees and change system mode Note When Display Lock or Guest Lock is selected a lock icon will appear next to the up arrow Note To disable Display Lock or Guest Access press and hold the up and down arrows until the lock icon disappears Once all selections have been made press the Done button to exit and return to Menu Press Next to navigate to the next setting User Guide User Settings Continued User Settings allow the user to customize various settings on the 624 control To access User Settings simply press the Menu button once and User Settings will be displayed To enter the User Settings menu press the Select button then use the Next button to navigate through the options below The default setting will be shown in brackets After each selection press the Done button to save changes Date 1 31 Time Date Setting Range Description Hour 1 12am 1 12 pm Select the current hour of day Minutes 0 59 Select current minute of day Day of Week Sun Sat Select current day of week Year 2013 2113 Select current year Month Jan Dec Select current month of year Select current day of month Once all selections have been made press the Done button to exit and r
18. ipping and freight expenses required to ship Product replacement parts Failures defects or damage including but not limited to any loss of data or property caused by 1 any third party product service or system connected or used in conjunction with the Products 2 any use that is not designed or intended for the Products 3 modification alteration abuse misuse negligence or accident 4 improper storage installation maintenance or operation including but not limited to operation of electrical equipment at voltages other than the range specified on the Product nameplate 5 any use in violation of written instructions or specifications provided by Company 6 any acts of God including but not limited to fire water storms lightning or earthquakes or any theft or riots or 7 a corrosive atmosphere or contact with corrosive materials such as but not limited to chlorine fluorine salt provided that indoor and outdoor coils will only be covered if a Sea Coast Kit is installed sulfur recycled waste water urine fertilizers rust or other damaging substances or chemicals Products purchased direct including but not limited to Internet or auction purchases and purchases made on an uninstalled basis Cabinets or cabinet pieces that do not affect product performance air filters refrigerant refrigerant line sets belts wiring fuses surge protection devices non factory installed driers and Product accessories
19. nternal schedule or by pressing the Set point Up Down buttons Pressing the setpoint button changes the setpoint screen The current mode is dis played at the top of the screen Adjust the setpoint by pressing the up or down arrows To change setpoint mode press the MODE button See TIME DATE for more information If the control is connected to Nexia Home Intelligence the clock will be updated by the Nexia portal The setpoints will push each other if they are adjusted to within the minimum heat cool separation setting This is normally 3 degrees The Comfort Control displays the current temperature The internal temperature sensor can be adjusted as as sensed by the internal temperature sensor necessary Button used to access other Comfort Control menus Other Comfort Control menus can be accessed by pressing the MENU button Button used to change the system mode Button used to change the fan mode Button used to change the schedule mode Off System off Heating Heating only Cooling Cooling only Auto Heating Cooling as necessary EM Heat Indoor Heat only Auto Fan on when cooling heating is necessary On Fan constantly on Circ Fan on for a user selected number of minutes per hour Hold System maintains the current temperature set points Schedules are disregarded Run Run the system schedule Energy Saving Mode ESM Temperature setpoints in ESM Setpoints are maintained User Guide
20. on The Edit Home screen button is located about mid way own the Nexia Home Page Dashboard Automation Event History My Alerts My Account Viewing QA2 Home june 17 2013 12 30pm COT 80211 Dashboard ta SENSORS a New Nexia Features and Functionality New Nexia Automation Functionality Our latest release includes more intuitive and flexible Scenes and Schedules are now combined VIDEO features for your Nexia system including under one Automation tab New capabilities Video All cameras and videos are now under one tab New format to set up simple or complex el LIGHTING amp 5 Lock codes On all Schiage looks you now have the automated actions ability to a user le to multiple locks same T gt MODULES time Ability to start an automated action based on mulitple triggers Alerts Create manage and customize alerts in the new My Alerts tab Easier to create delayed actions for CLIMATE automations z z Device Event Date Time arh r Garage Enury Unlocked ynnjans e Front Entry Light Tumed off 17 Jun 2013 05 59 am Front Entry Light Activated 17 Jun 2013 off automation 05 59 am Garage E ht Turned off 17 un 2013 sist 203 am Backyard Pato Turned off 17 un 2013 Ughi 1202 am Garage Entry Light Activated 17 3un 2013 E a aa 20h am mame am em Corana Enen tacked ethno T Q Aco rome 2012 Schiage Privacy Policy Terms end Conditions Subscriber Community Where to Buy Contact Nexia Heip E
21. operly registers the Products the limited warranty period shall be extended as stated in Tables 1 1A 1B attached hereto Regardless of registration the Commencement Date for a limited warranty period shall be the date that the original installation is complete and all Product start up procedures have been properly completed and verified by an installer s invoice If the installation and start up date cannot be verified by the installer s invoice the Commencement Date shall be sixty 60 days after the factory manufacture date which is verified by the Product serial number Where a Product is installed in a newly constructed home the Commencement Date is the date the Purchaser purchased the residence from the builder Proof of Product purchase installation and or closing date of the residence may be required to confirm the Commencement Date The installation of Product replacement parts under this limited warranty shall not extend the original warranty period The warranty period for any Product part re placed under this limited warranty is the applicable warranty period remaining under the original Product warranty WHO IS COVERED This limited warranty is provided only to the original owner and his or her spouse Purchaser of the residence where the Products are originally installed This warranty is not transferable except according to terms stated on the applicable website identified below under Registration Requirements Company has the
22. ort pages warranty aspx and click Begin Online Registration If a Purchaser does not register within this stated time period the base limited warranty terms shall apply ELIGIBILITY REQUIREMENTS The following items are required in order for the Products to be covered under this limited warranty The Products must be in the same location where they were originally installed The Products must be properly installed operated and maintained by a licensed HVAC service provider in accordance with the Product specifications or installation operation and maintenance instructions provided by Company with each Product Failure to conform to such specifications and or instructions shall void this limited warranty Company may request written documentation showing the proper preventative maintenance All Product parts replaced by Company under this limited warranty must be given to the servicing provider for return to Company Air handlers air conditioners heat pumps cased or uncased coils and stand alone furnaces must be part of an Air Conditioning Heating and Refrigeration Institute rated and matched system or a specification in a Company provided bulletin or otherwise approved in writing by a Company authorized representative EXCLUSIONS The following are not covered by this limited warranty e Labor costs including but not limited to costs for diagnostic calls or the removal and reinstallation of Products and or Product parts Sh
23. right to request any and all proof of Product purchase or installation and or closing date of the residence WHAT COMPANY WILL DO Company may request proof of Product purchase and or installation in order to provide Product parts under this limited warranty As Company s only responsibility and Purchaser s only remedy under this limited warranty Company will furnish a replacement part to the licensed HVAC service provider without charge for the part only to replace any Product part that fails due to a manufacturing defect under normal use and maintenance The Purchaser must pay for any and all shipping and handling charges and other costs of warranty service for the replacement part If a Product part is not available Company will at its option provide a free suitable substitute part or provide a credit in the amount of the then factory selling price for a new suitable substitute part to be used by the Purchaser towards the retail purchase price of anew Company product Any new Product purchase shall be at Purchaser s sole cost and expense including but not limited to all shipping removal and installation costs and expenses REGISTRATION REQUIREMENTS All Products must be properly registered online by the Purchaser within sixty 60 days after the Commencement Date to receive the registered limited warranty terms To register online go to http www trane com Residential For Owners Warranties or http www americanstandardair com servicesupp
24. rt Control has NOT been successfully enrolled In this case repeat step 18 and verify again d Press Done button 2 times when finished Item Description VERSION 010000 Firmware version number may vary ZWAVE VER 034006 Z Wave version number may vary NODE ID 01 Z Wave node ID number may vary HOME ID 00000000 Z Wave Home ID number may vary OUT TYPE AC Outdoor type may be AC HP or NONE C O WITH COOL Energize Reversing Valve with COOL or with HEAT HP only IN TYPE GAS OIL Indoor type may be GAS OIL ELECTRIC or HYDRONIC User Guide Enroll Comfort Control into existing Z Wave Network Nexia Home Intelligence Continued 4 Establish Online Connection to the Comfort Control Nexia Home Intelligence account must be active before continuing See nexiahome com for more information a Remove the battery from the bridge b Plug the Ethernet and power cord back into the bridge c Log into your account at www mynexia com d Click the Climate tab and follow the on screen instructions Note If the new thermostat icon remains gray or cannot be controlled remotely you might need to add Z wave repeaters to improve communications Contact your local Nexia expert or call 877 288 7707 for assistance Un enroll Comfort Control from existing Z Wave Network Nexia Home Intelligence 1 If you need to remove the 624 from a Nexia Home Intelligence account follow
25. the Exclusion steps This will delete the ability to control the thermostat remotely If you are unsure please contact Nexia support at 877 288 7707 Install a new high quality 9 volt battery into the bridge a Hold the bridge within 6 feet 1 8 meters of the Comfort Control throughout the entire exclusion process gt After you begin the exclusion process you have 30 seconds to complete the remainder of the steps Study the steps below before beginning Press and release the minus button on the bridge Press the MENU button on the Comfort Control Press NEXT button to scroll to Z WAVE screen then press SELECT Press the Yes button to exclude the Comfort Control Observe the lights on the bridge The orange light will blink while exclusion is taking place Exclusion is complete when the orange light becomes solid gt Z Wave controllers from various manufacturers may support the Z Wave Thermostat General V2 Device class used by the Z Wave Comfort Control If you are using a controller that is not a Nexia bridge consult the instructions that came with the controller to find out how to enroll a new device 9290 User Guide Firmware Upgrades 1 Firmware Upgrades allow the user to update the 624 control Upgrades may take up to 45 minutes The system operation will be maintained during the upgrade process To access the Firmware Upgrades navigate to mynexia com and look for the Edit Home screen butt
26. the lowest cooling setpoint allowed H C Delta 3 15 Degrees Select the minimum deadband between Heating and Cooling setpoints Once all selections have been made press the Done button to exit and return to Menu Press Next to navigate to the next setting Energy Savings Mode Setting ESM Heat Setpoint Range Description Select the desired Heating Setpoint when ESM Energy Savings Mode is 55 90 degrees 62 selected ESM Cooling Setpoint 60 99 Degrees 85 Select the desired Cooling Setpoint when ESM Energy Savings Mode is selected Once all selections have been made press the Done button to exit and return to Menu Press Next to navigate to the next setting Display Setting Range Description Screen Timeout 0 90 Seconds Select how long after the last button press before the screen timeouts to a minimized screen Backlight Timeout 0 90 Seconds 20 Select how long after the last button press before the backlight dims Backlight On Percent 0 100 Percent Select the screen brightness when the backlight is lit Backlight Off Percent 0 100 Percent Select the screen brightness when the backlight timeout expires Buzzer Enable Yes No Select whether button presses are audible Security Unlocked Display Lock Guest Access Select security level e Unlocked Enables selection of all menus and sett
27. ww trane com or www americanstandardair com Table 1A Warranty Time Periods for Controls Zoning Products Humidifiers Energy Recovery Ventilators Air Cleaners and Oil Furnaces Variable and Non Variable Speed COVERAGE TERMS FOR RESIDENTIAL APPLICATIONS Pursuant to the Trane U S Inc Company limited warranty terms and conditions the following Products are covered for the base time periods as stated below Base Limited Warranty period If registered the Base Limited Warranty Periods for certain products will be extended as stated below Registered Limited Warranty Period CONTROLS CONT200 CONT401 CONT402 CONT600 amp CONT602 Base Limited Warranty Period one 1 year Registered Limited Warranty Period five 5 years CONTROLS ZEMT500 CONT624 CONT800 CONT802 CONT803 CONT824 CONT900 ZONE940 ZONE950 Base Limited Warranty Period five 5 years Registered Limited Warranty Period ten 10 years ZONING PRODUCTS ZONE950 ZONE940 ZONE930 ZZONEPNLAC52Z ZZONEEXPAC52Z ZZSENSAL0400 BAYSENO1ATEMPA BAY24VRP ZDAMPRD ZDAMPSM ZDAMPBM ZDAMPRR Base Limited Warranty Period five 5 years Registered Limited Warranty Period ten 10 years HUMIDIFIERS HUMD200 HUMD300 amp HUMD500 Base Limited Warranty Period five 5 years Registered Limited Warranty Period ten 10 years ENERGY RECOVERY VENTILATOR ERV ERVR100 ERVR200 amp ERVR300 Base Limited Warranty Period five 5 years Re