Home

iSerial User Manual

image

Contents

1. Using DHCP will mean that the IP address of the Gi lt m ISERIAL May change making it much more difficult to maintain your connection to the Ecm ISERIAL If you choose to use DHCP it is assumed that you have your own reasons for doing so that you know what you are doing and that you won t need instruction or guidance 5 0 System Status This screen shows the GICM ISERIAL current status All of the information provided is read only system Status MAC Address 00 00 11 33 FF 00 Nickname NetUART Update System Version 3 0 060110 5 1 Load default setting Allow Users to reset the EIM initial value but the MAC Address will not be updated Load Default Setting to EEPROM Load ISERIAL to return the 5 2 Operation mode The Gicm ISERIAL supports four operation modes TCP Server TCP Client UDP Server and UDP Client These modes are listed in the Web page for the Operation Mode setting Each setup screen and available features will differ depending on what kind of operation mode you select Default is TCP Server Em METERING kWh meters utilize TCP Server mode 5 3 TCP Server Port Number default 50000 range 0 to 65535 If your device is acted as passive to accept commands from remote and the data be guaranteed to be received by peer is your concern then you can set GICM ISERIAL as TCP Server Be sure the value of item Port Number is same as your remote control application using Client mode inacti
2. that opens type ipconfig no quotes and hit the ENTER key ct C WINDOWS system3 2 cmd exe Connection specific DNS Suffix hsdi ca comcast net IP s 2 Se Subnet Mask 255 0 Default Gateway z E Ge h Documents and Settings compaquser gt ipconf ig Mindows IP Configuration thernet adapter Local Area Connection Connection specific DNS Suffix VP AddPasS e262 as a ok wt ar ar a ot ae SEES LOR Subnet Mask s 255 255 Default Gateway Ethernet adapter Wireless Network Connection Connection specific DNS Suffix hsdi ca comcast net IP t 0 93 Subnet Mask z 255 0 Default Gateway z ep Eh i Documents and Settings compaquser gt The information returned will tell you your IP address If IP address is in the range range 192 168 1 xxx skip to section 4 3 If not go to the following section 4 2 4 2 Step 1 From the START menu choose Settings gt Control Panel gt Network Connections Double click the Network Connections icon In the Network Connections window double click Local Area Connection S Network Connections File Edit View Favorites Tools Advanced Help Back Bi 4 Search i Folders Ei s Network Connections kal Goa eee S LAN or High Speed Internet Network Tasks il Create a new connection ce HP Set up a home or small office network Change Windows te Firewall settings mie Sd MetXtreme Gigabit E g B
3. EIKMmMm iISERIAL V 2 3 0 Hardware Installation amp Initial Setup TCP IP to RS232 422 485 Converter 3 1 RS 232 Pinout DB9 Male 3 6 Connection Diagram User s Manual DB9Male Siora RS 232 Connection RS232 maii i E DB9 Female DB9 Female RD 2 1 0 Introduction The GICM ISERIAL is a cost effective and highly eis integrated Serial to Ethernet Converter Embedding a 3 2 RS 422 485 Pinout six Terminal from left GND 5 8051CPU 64KB OTP ROM 32K bytes SRAM 10 100Mbps Terminal J 5 P Ethernet and serial port support handshake RTS CTS The No RS 422 Connection i 9 24 EKM ISERIAL can control 1 x RS232 422 485 devices a pte f fee fe 238 ono located virtually anywhere via Ethernet or Internet VDC San RS 422 Automatically finds devices in the network Configuration 9 24 k R i i o ese aes 928 eno a i over Driver Panels serial Port Telnet WEB Browser R 4 T SNMP Automatic mode switching between Driver and _ EIM SERIAL RAW mode Support TCP IP UDP DHCP PPPoE 3 3 Connect to 10 100M EKM ISERIAL 10 100 M Port Connect to a switch or TRPA e o e 44D 2 0 Features HUB using a straight through cable F 3 in 1 RS 232 422 485 interface Max 230Kbps Serial 3 4 Power Supply interface and 10 100 Mbps Ethernet The Gicm ISERIAL TCP IP converter can use the RS 485 Connection Supports 4 and 2 wire RS 485 with AUTO SEND and product s 9V power a
4. ERIAL as TCP Client Be sure the value of item Remote Connection Port Number is same as your remote control application using and set the correct value of Remote Host IP Address 5 7 UART Control RS 232 RS 422 RS 485 The GICM ISERIAL supports three serial types RS232 RS422 and RS485 Select the appropriate Mode EIM METERING kWh meters utilize RS 485 serial mode and the following default settings Baud Rate default 1200 range 300bps to 230 4Kbps Character Bits 5 6 7 default 8 Parity Check Even default even odd space mark Stop Bits 1 default 1 5 or 2 Hardware Flow Control None default CTS RTS or Hardware UART Control tem Current value Setting Baudrate 1200 1200 Character Bits 7 7 Parity Type even even Stop Bit i a Hardware Flow Control none none gt Update
5. Manager of the relevant setting page 4 4 Authentication Configuration The Users can change the username and password to prevent unauthorized access Login ID and password authentication the maximum is 15 characters and numbers User Name default admin Password default admin Authentication Configuration Setting Value adnan max 15 Password a max 15 Confirm me Update Username 4 5 System IP Configuration The EIM 1S RIAL supports two IP connection types Static IP DHCP These types are listed in the Web page for the IP Configuration setting Each setup screen and available features will differ depending on what kind of IP connection types you select Default is Static IP We will only guide you through the use of Static IP and its configuration System IP Configuration Setting Value IP Address fica files p ft Subnet Mask 55 255 255 po PE ew ONS a ie Ps Static DHCP Gateway IP Configure Static or Fixed IP IP Address default 192 168 1 125 Subnet mask default 255 255 255 0 Gateway default 192 168 1 1 Primary DNS default_ 0 0 0 0 If you have need to change these settings perform these steps Step 1 Enter IP address that is consistent with your LAN IP address range Step 2 Enter Subnet mask Step 3 Enter Gateway Router IP address Step 4 Enter Primary DNS IP address Step 5 click Update button 4 6 DHCP
6. dapter for power supply or use other DC built in terminator power or device 9 24VDC 500 1000mA Supports industrial 24 VDC power input 3 5 EKM ISERIAL LED indication onion Device LINK Indication Ethernet Link Green on Ethernet Link Terminal block accessories for easy RS 422 485 serial wiring ember OARRA Supports IP configuration by MAC address established Supports configuration store and copy for easy deployment ACT Data Sending Receiving between Serial and the E Devi e e o i Supports Driver TCP Server Client UDP Server Client Pair Ethernet evice Device PWR Indication of Power ON Connection operation modes Easy and powerful configuration program Approval CE RoHS 4 0 Configuration and Operation For your computer to be able to communicate with your EIC mM ISERIALL your computer must have an Ethernet card and TCP IP installed TCP IP should already be installed on computers using Windows 98 2000 XP and later operating systems If your LAN Local Area Network already uses the IP address range 192 168 1 xxx skip to section 4 3 If not use section 4 2 to set up your computer to assign it a static IP address in the 192 168 1 2 to 192 168 1 254 range with a subnet mask of 255 255 255 0 If you are not sure what your LAN IP address range is use the following section 4 1 4 1 From the START menu choose Run Type cmd no quotes in the edit field and click OK In the window
7. roadi reen MLOGE Connection JE Local Area Connection In the Local Area Connection Status window click the Properties button Local Area Connection Status General Support Connection Status Connected Duration 15 days 11 18 24 Speed 1 0 Gbps Received Packets I Properties Disable In the Local Area Connection Properties window select Intrnet Protocol TCP IP Y and click the Properties button 4 Local Area Connection Properties General Authentication Advanced Connect using S Broadcom NetXtreme Gigabit Etheme This connection uses the following items C2 Client for Microsoft Networks v B File and Printer Sharing for Microsoft Networks v aos Packet Scheduler vi 3 Intemet Protocol TCP IP Install Uninstall Properties Description Allows your computer to access resources on a Microsoft network Show icon in notification area when connected Notify me when this connection has limited or no connectivity OK Cancel In the Intrnet Protocol TCP IP Proerties window note if Obtain and IP address automatically or Use the following IP Address is selected If Use the following IP Address is selected write down the IP address and Subnet mask settings You will need these settings to restore your computer s Original settings Click the radio button for Use the following IP Address In
8. ternet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address Subnet mask Default gateway Use the following DNS server addresses Preferred DNS server Altemate DNS server Advanced L ok _Cancel_ In the IP address line enter the IP address 192 168 1 237 In the Subnet mask line enter 255 255 255 0 Click OK Click OK Click Close Step 2 Open your web browser and type http 192 168 1 125 in the browser s address box This address is the factory set IP Address of your GICM ISERIAL Press Enter Step 3 The ID and Password required prompt box will appear Type admin default username in the ID field and typie admin default password in the Password field Click OK The setup screen will then appear USER IN Site 192 168 1 125 ID hmin SSCSC S Password pp User login to enter a password Default ID Default Password admin admin 4 2 The menu features as below Administrator Authentication System IP system Status Load default setting Functions TCP Mode UDP Mode UART Reset Device All of the above functions are explained below 4 3 Administrator Setup
9. ve timeout minutes default 20 0O Disable If you want to keep the connection between GI cm ISERIAL and your remote control application always on then set the value of item Client mode inactive timeout minutes to 0 otherwise when the inactive time of no any traffic on line reach the setting value GICM ISERIAL will terminate this connection 5 4 TCP Client Remote Connection Port Number default 50000 range 0 to 65535 Remote Host IP Address default 210 200 181 102 If your device is acted as active to report real time status to remote and the data be guaranteed to be received by peer is your concern then you can set GICM ISERIAL as TCP Client Be sure the value of item Remote Connection Port Number is same as your remote control application using and set the correct value of Remote Host IP Address 5 5 UDP Server Local Port Number default 50000 range 0 to 65535 If your device is acted as passive to accept commands from remote and the data be guaranteed to be received by peer is not your concern then you can set EIM ISERIAL as UDP Server Be sure the value of item Local Port Number is same as your remote control application using 5 6 UDP Client Remote Connection Port Number default 50000 range 0 to 65535 Remote Host IP Address default 192 168 1 2 If your device is acted as active to report real time status to remote and the data be guaranteed to be received by peer is not your concern then you can set the Ecm IS

Download Pdf Manuals

image

Related Search

Related Contents

Fujitsu PRIMERGY TX100 S1  MANUALE PER l`ISTALLAZIONE E LA  Lightolier Calculite 6" Compact Fluorescent DC User's Manual  ASUS X550CA-XO591H  MANUAL DE INSTRUÇÕES para as prensas transfer Secabo TC 2  Brother PE-600II User's Manual  Baker WinAST  Samsung GT-S7330 Uživatelská přiručka  日本の判例状況一覧 最終版 20140623    

Copyright © All rights reserved.
Failed to retrieve file