Home
        Kelly KLS8080I/IPS User Manual V1
         Contents
1.    Value Range 0 1023 maps 0 5V     6 Line Hall Amplitude The position signal based on Zero crossing point It is only useful when  the speed sensor is at 4    For example if the Line hall Amplitude is 1 1V the signal output of Sine Cosine sensors is from  1 9V to 4 1V  3 1 1 1 9V 3 1 1V 4 1V    Value Range 0 1023 maps 0 5V     7 Line Hall High Err lt is only useful when the speed sensor is at 4    If the signal output of Sine Cosine speed sensor is above this setting the controller will report  hall error Please adjust Line Hall High Err to a higher value to eliminate this error    Value Range 0 1023 maps 0 5V     8 Line Hall Low Err It is only useful when the speed sensor is at 4    If the signal output of Sine Cosine speed sensor is below this setting the controller will report  hall error also Please adjust Line Hall Low Err to a lower value to eliminate this error    Value Range 0 1023 maps 0 5V    18    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    4 3 Step 3     1 RLS_TPS Brk    RLS TPS Braking Percent  the percent of Releasing Pedal BRK in max  braking  Range  0 50   This is used to adjust the regen current of releasing throttle regen mode type The regen will  happen as long as the throttle is released completely    Factory set is 0     2 NTL Brk    NTL Braking Percent  the percent of Neutral Braking in max braking  Range   0 50   Only useful when you enable Three gears switch in user program    The regen will happen when you turn F
2.   17  3 hall position sensor inputs  Open collector  pull up provided Sin Cosin Speed  sensors inputs     18  Enhanced regen brake function  A novel ABS technique provides powerful and  smooth regen The regen can happen at any speeds until zero speed     19  Cruise control     20  KLS 8080I IPS can support Broadcast type CAN bus function lt is 250Kbps     A    Caution  The regen is not a safe function  Usually you may use the mechanical brake     Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    2 2 Features    1  Intelligence with powerful microprocessor    2  Synchronous rectification  ultra low drop  fast SVPWM and FOC to achieve very high   efficiency      Electronic reversing      Voltage monitoring on 3 motor phases  bus  and power supply      Voltage monitoring on voltage source 12V and 5V      Current sense on all 3 motor phases      Current control loop    8  Hardware over current protection      Hardware over voltage protection    0  Configurable limit for motor current and battery current    1  Low EMC    2  Battery protection  current cutback  warning and shutdown at configurable high and low  battery voltage      Rugged aluminum housing for maximum heat dissipation and harsh environment      Rugged high current terminals  and rugged aviation connectors for small signal    15  Thermal protection  current cut back  warning and shutdown on high temperature      Controller can do auto_Identification angle for different Sine Cosine Spe
3.   Controller case temperature is above 90  C   warning Current will be limited  Reduce controller loading  or switch Off until controller cools down    2  Clean or improve heatsink or fan    2 1 mo a Motor did not start  Motor did not reach 25 electrical RPM within 2  seconds of start up  Hall sensor or phase wiring  problem    2 2 aa aa Internal volts fault 1  Measure that B   amp  PWR are correct when   measured to B  or RTN    2  There may be excessive load on the  5V supply  caused by too low a value of Regen or throttle  potentiometers or incorrect wiring    3  Controller is damaged  Contact Kelly about a  warranty repair    2 3 oa aaa Over temperature  The controller temperature has exceeded 100  C  The  controller will be stopped but will restart when  temperature falls below 80  C    2 4 xa aaa    Throttle error at Throttle signal is higher than the preset    dead zone    at   power up Power On  Fault clears when throttle is released    3 1 noo a Frequent reset May be caused by over voltage  bad motor  intermittent earthing problem  bad wiring  etc    3 2 aga aa Internal reset May be caused by some transient fault condition like  a temporary over current  momentarily high or low  battery voltage  This can happen during normal  operation    3 3 paa aan Hall throttle is open When the throttle is repaired  a restart will clear the   or short circuit fault    3 4 xaa paan Non zero throttle on Controller won t allow a direction change unless the   direction change throttle
4.   Customers can do program on PC software or Android App The Android Tablet is  prefered First of all oeople need to do Identification angle function for KLS controller before  running the motor The controller needs to be connected to batteries motor and throttle before  Identification operation That is to say  it is not enough to connect only power supply PWR pin7   to batteries for Identification Angle operation     Please download the instruction how to use Identification angle function from our website   www kellycontroller com support php    4 1 Step 1     1 Low Volt  The min voltage of reporting this fault   Range 18 180  Controller will not operate when battery voltage is near the value so as to protect battery   Suggestion  Set according to the practical situation By default  it is set at 18V      2 Over Volt  The max voltage of reporting this fault   Range 18 180   Controller will not operate when battery voltage is higher than the value so as to protect battery  and controller    Suggestion  Set according to the practical situation    Here is the max voltage for each model    72V controller 90V   96V controller 120V   120V controller 136V   144V controller 180V    13    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual    V 1 5 02                                     Controller Rated voltage   Under Voltage Range  V    Over Voltage Range V   72V 18 90 18 90  96V 18 120 18 120  120V 18 136 18 136  144V 18 180 18 180  Figure 4 1     3 Current Perce
5.  IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    3 2 2 Standard Wiring of KLS8080I IPS Controller       Battery pack    2K 20W Precharge resistor      ie    Main contactor    HAR     KLS8080I Controller    Fuse    B  Red Ure  Black                            Yellow    BLDC motor with hall sensors       5V Purple                                          Hall A Yellow  Hall B Green Hall Sensors  Hall C Blue        GND Black    GND Black  Motor Temp Raddle                               PWR Pink       Reverse Orange          Forward White  12V Red             Boost Brown       Boost Switch    Micro SW Ga              5V Purple  Throttle NavyGreen oA  GND Black               DJ7061Y 2 3 21       12V Brake Yellowish       o  Brake Switch        1 The switch signal is valid to 12V  2 12V only can be used for LED or Switch signals       Figure 3  KLS8080I controller standard wiring    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    Battery pack            KLS80801PS Controller       Main contactor               BLDC motor with hall sensors       Hall B Dark Green Cosin Sin Cosin  Hall C Dark Blue Speed Sensors  GND Black  GND Black  Motor Temp Raddle                                         PWR Pink    O E  Key switch 2A Fuse       Reverse Orange    Forward White                             Reversing switch          Boost Brown     Boost Switch Throttle  Micro SW Ga  sv Purple  Throttle NavyGreen a         GND Black leno  B  12V B
6.  N R switch from Forward or backward to Neutral  position    Factory set is 0     3 Accel Time  Accel Time  the time of TPS Torque from O to max  accuracy 0 1s  5 is equal to  0 5s  Range  1 250  Factory set is 10     4 Accel RIs Time  Accel Release Time  the time of TPS Torque from max to 0  accuracy 0 1s   Range  1 250  Factory set is 1     5 Brake Time  Brake Time  the time of Brake Torque from 0 to max  accuracy 0 1s  Range   1 250  Factory set is 15     6 Brake Rls Time  Brake Release Time  the time of Brake Torque from max to 0  accuracy 0 1s   Range  1 250  Factory set is 1     7 BRK_SW Brk    BRK_SW Braking Percent  the percent of BRK_SW in max braking  Range   0 50   The brake switch regen mode You have to turn on the brake switch after the throttle is released  for the regen to occur    Factory set is 10     8  Torque Speed KP  Speed Percent Kp in Torque Mode  Range  0 10000 Factory set is 3000  Torque Speed KI  Speed Integral Ki in Torque Mode  Range  0 500 Factory set is 80   Speed Err Limit  Speed Error Limit in Torque Mode  Range  50 4000 Factory set is 1000   These three parameters are used for PID adjustment    If you think the acceleration performance is very very strong please adjust them to a lower value  respectively     19    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02     9 Change Dir brake Value range  Enable and Disable   It is only useful when you Enable the joystick function    If you want to get swift direction ch
7.  or speed is at zero  Fault clears when throttle  is released    4 1 mood a Regen or Start up Motor drive is disabled if an over voltage is detected   over voltage at start up or during regen  The voltage threshold  detection level is set during configuration    4 2 paon na Hall sensor error 1  Incorrect or loose wiring or a damaged hall sensor   2  Also be caused by incorrect hall angle  configuration  60 degree or 120 degree    4 3 nooo ama Motor Motor temperature has exceeded the configured    maximum  The controller will shut down until the          motor temperature cools down        V 1 5 02    22    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual    Contact Us     Kelly Controls  LLC    Home Page   http  Awww KellyController com    E mail     Sales Kelly Controls com    Phone    01  224 637 5092    V 1 5 02    23    
8. 0I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    Chapter 1 Introduction    1 1 Overview    This manual introduces the Kelly sinusoidal wave brushless BLDC motor  controllers    features  their installation and their maintenance  Read the manual carefully  and thoroughly before using the controller  If you have any questions  please contact the  support center of Kelly Controls  LLC     Kelly   s programmable motor controllers provide efficient  smooth and quiet controls  for electric motorcycles  golf carts and go carts  as well as industrial motor control  It is mainly  supposed to solve noise problems of BLDC motor driving application  KLS controller can not  support sensorless brushess motor for now Compared to the traditional trapezoidal waveform  control technology  this technique based on sinusoidal wave driving technology to reduce the  operation noise and 1 3 switching loss  which well meets the noise reduction and efficiency  requirements in the application of DC brushless motor  It uses high power MOSFET   s and   SVPWM and FOC to achieve efficiencies of up to 99  in most cases  A powerful  microprocessor brings in comprehensive and precise control to the controllers  It also allows  users to adjust parameters  conduct tests  and obtain diagnostic information quickly and  easily People can program the KLS controller on PC software and Android App There is one  more choice for customers to program KLS controller now The APP software is based on 
9. Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    Kelly KLS8080I IPS Motor    Controller User s Manual    KLS72501 80801 KLS72601 80801 KLS72701 80801  KLS96501 80801 KLS96601 80801 KLS12401 80801  KLS12601 80801 KLS14201 80801 KLS14301 80801    KLS72501 8080IPS KLS72601 8080IPS KLS72701 8080IPS  KLS96501 8080IPS KLS96601 8080IPS KLS12401 8080IPS  KLS12601 8080IPS KLS14201 8080IPS KLS14301 8080IPS       Rev 1 5 02  September 2015    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    Contents  Chapter 1 Introduction  scsisaind aik EE KERKEE En 2  OI A nn E  ey doaes eet 2  Chapter 2 Features and SpecificatiOnS                coocoononnnonononornorraronrnons 3  Za General TUNISIA a eae 3  22 PRAMS A A did 4  pS GI ALON So cactus Sova cuss cavtect usec ae E EEN acoso he gears die ase Re 5  2A NTS  Req A EN NE BE 5  Chapter 3 Wiring and  Installation 6  3 1 Mounting a A nde sdsere at eadees cadacanvesececstenntetcaderde acted tdecds sees 6  3 2 COMPS CHONG eos dit cit REA AEA T  3 2 Installation Check ISE A AA A Ms AN 12  Chapter 4 Programmable Parameters      ooccoccocnoncnoconinoniconanonncnanonanonanonnoranaranonos 13  AMES AA AA INS AN RR 13  4 2 Step A fa eaag alec A E aul ala aaah tase oe tanec a 18  ARSE  1e  Ps o a e 18  Chapter 5   Maintenant sessioon EEEE SEES 20  A AS 20  52 GOMMOUAM ON 2 ht a a as hatin Seales Madara iba a abate evict E AA 20  Table 1 ERROR CODES ido rd 21  Contactanos 23    Kelly KLS808
10. LS8080I controller    3 3 Installation Check List    Before operating the vehicle  complete the following checkout procedure  Use LED code as  a reference as listed in Table 1        Caution    e Put the vehicle up on blocks to get the drive wheels off the ground before beginning these  tests      Do not allow anyone to stand directly in front of or behind the vehicle during the checkout        Make sure the PWR switch and the brake is off     Use well insulated tools              e Make sure the wire is connected correctly  e     Turn the PWR switch on     e The fault code will be detected automatically at restart     12    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    e With the brake switch open  select a direction and operate the throttle  The motor should    spin in the selected direction  Verify wiring or voltage and the fuse if it does not  The motor  should run faster with increasing throttle  If not  refer to the Table 1 code  and correct the  fault as determined by the fault code       Take the vehicle off the blocks and drive it in a clear area  It should have smooth    acceleration and good power     Chapter 4 Programmable Parameters    KLS Configuration program allow users to set parameters according to the vehicle actual  working environment so as to be at its best    The default parameters of the controller are not recommended for all applications  Make  sure set the proper parameters before making any test to avoid danger  
11. PS High Err  Hall active pedal  if higher than the value  report the fault of TPS Type  Range   80 100   As you may know the output of hall throttle from Kelly is about from 0 86V to 4 2V    Our controller will report 3 3 error code if the output of hall throttle is below 0 5V or above 4 5V  by default    The controller will think the hall throttle is shorted or damaged if the output is beyond the range  from 0 5V to 4 5V    You can adjust the threshold voltage below or above 0 5V The controller will report the 3 3 code  to protect the system according to different types of hall throttle    Because there are many different hall throttle suppliers in the world The initial output can not be    14    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02  always in the range of 0 5V to 4 5V     But it doesn t make any differences if you choose 0 5V or 3 wire pot for the throttle type  That is  to say these two settings are only useful for hall active throttle or pedal when you chose throtle  type at 2     As the same goes  it is valid to adjust the high threshold voltage above 4 5V or below 4 5V   Usually the hall output voltage is 4 2V Max If you adjust it to lower value which is near 4 2V it  may trigger the error code in normal way      8 TPS Type  TPS Type  1 0 5V 3 wire 0 5K pot 5K is normal 2K 20K can be used 2 Hall active  throttle or pedal  Range  1 2     9 TPS Dead Low  TPS Dead Zone Low  Range  5 40  Functional description  Set throttle effecti
12. Tablet  with Android OS Customers may add a Z TEK USB to RS232 cable for programming KLS  controller if they want to use Android Tablet    Both PC software and Android APP can provide one screen to monitor the controller  parameters Sometimes people can use a small Android Tablet as display device    KLS8080I IPS is designed by opto isolated technology We specify 8 30V for power  supply which must be isolated from main battery pack B  B  You may use an isolated  DCDC converter or a separate 12V battery for power supply KLS8080I is supposed to  work with BLDC motor with hall sensors KLS8080IPS can work with brushless motor  with Sin Cosin speed sensors     KLS8080I IPS controller included the fuse and shunt on the case     Kelly KLS80801 1PS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    Chapter 2 Features and Specifications    2 1 General functions     1  Extended fault detection and protection  Customers can read the error code in PC  software or Android Tablet also     2  Monitoring battery voltage  It will stop driving if the battery voltage is too high and it  will progressively cut back motor drive power as battery voltage drops until it cuts  out altogether at the preset    Low Battery Voltage    setting     3  Built in current loop and over current protection     4  Configurable motor temperature protection range     5  Current cutback at low temperature and high temperature to protect battery and  controller  The current begins to ramp down at 90  C c
13. anging by using joystick function you may enable Change Dir  brake item in user program    It will help the motor change the direction of motor quickly after you shift throttle from OV to 5V or  from 5V to OV    Suggestion factory default is Disable     Note  Thermistor is optional  Default to KTY84 130 or 150    Chapter 5 Maintenance    There are no user serviceable parts inside the controllers  Do not attempt to open the  controller as this will void your warranty  However  periodic  exterior cleaning of the controller  should be carried out    The controller is a high powered device  When working with any battery powered vehicle   proper safety precautions should be taken that include  but are not limited to  proper training   wearing eye protection  avoidance of loose clothing  hair and jewelry  Always use insulated  tools     5 1 Cleaning   Although the controller requires virtually no maintenance after properly installation  the following   minor maintenance is recommended in certain applications    e Remove power by disconnecting the battery  starting with battery positive    e Discharge the capacitors in the controller by connecting a load  such as a contactor coil   resistor or a horn  across the controller s B  and B  terminals    e Remove any dirt or corrosion from the bus bar area  The controller should be wiped with a  moist rag  Make sure that the controller is dry before reconnecting the battery      Make sure the connections to the bus bars  if fitted are tigh
14. ase temperature  shutting down at  100  C     6  The controller keeps monitoring battery recharging voltage during regen braking     7  Maximum reverse speed and forward speed can be configured between 20  and  100  respectively and separately     8  A4pin connector to RS232 port and a Z TEK USB to RS232 cable allows for  configuration  programming and software upgrades using the tablet which must be  based on Android OS now People can do the same things on PC software by using  a standard USB to RS232 cable instead     9  Provision of a  5 volt and  12 volt output to supply various kinds of hall sensors     10  5 switch inputs which are activated by connection to 12V  Default to throttle switch   brake switch reversing switch forward switch and Boost switch     11  2 analog 0 5V inputs that default to throttle input  and motor temperature input    12  Copy signal of one of sensors     13  Configurable boost switch  Enables the maximum output power achievable if the  switch is turned on     14  12V brake switch input used different port from motor temperature sensor  You can use  both brake switch and motor temperature sensor functions at the same time on the latest  version Pin 25 is 12V brake switch input port Pin1 is motor temperature sensor input port     15  Optional joystick throttle  A bi symmetrical 0 5V signal for both forward and  reversing     16  Configurable motor over temperature detection and protection with the  recommended thermistor KTY84 130 or KTY84 150   
15. ed sensors Can  adjust the zero crossing point and signal amplitude to match different Sine Cosine speed  sensors    17  Configurable high pedal protection  the controller will not work if high throttle is detected at  power on    18  Current multiplication  Take less current from battery  output more current to motor    19  Easy installation  3 wire potentiometer will work    20  Standard PC Laptop computer to do programming  There is one more choice for customers  to program KLS controller Standard Tablet with Android OS to do programming Need a  Z TEK USB TO RS232 cable for connecting the controller to App program in Tablet    21  User program provided  Easy to use  No cost to customers    22  Support motors with any number of poles    23  Up to 70 000 electric RPM standard   Electric RPM   mechanical RPM   motor pole   pairs Motor pole pairs Motor poles 2      Kelly KLS80801 1PS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    2 3 Specifications     Frequency of Operation  20kHz    e Standby Battery Current   lt  0 5mA     5V or 12V Sensor Supply Current  40mA    e Controller supply voltage range  PWR  8V to 30V for pin7 and pin6 which must be isolated  from main battery pack B  B     e Supply Current  PWR  30mA Typical     Configurable battery voltage range  B   Max operating range  18V to 1 25 Nominal Voltage    Standard Throttle Input  0 5 Volts 3 wire resistive pot   1 4 Volts hall active throttle     e Throttle Input  0 5 Volts  Can use 3 wire pot to p
16. ggestion factory default is Disable    17       Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    4 2 Step 2     1 Motor Poles  Motor Poles  The pair pole number 2  Range  2 128  Suggestion  Set according to the real motor poles on the nameplate of the motor  factory default  is at 8      2 Speed Sensor Type  Speed Sensor Type  2 Hal  3 Resolver  4 Line Hall  Range  2 4  Different sensors type By defualt it is set at 2   If you have a motor with 5V Sin Cosin GND speed sensors please choose it at 4 And please  inquire the KLS 8080IPS model before ordering      3 Resolver Poles  Resolver Poles  The pair pole number 2  Range  2 32  It is only used for the Resolver sensor type      4 Motor Temp Sensor  Motor Temp Sensor  0 None  1 KTY84 130 or 150  Range  0 1   High Temp Cut Out    C  Motor High Temp Cut Out  nominal value 130   C  Range  60 170  Resume    C  Motor High Temp Resume Temp  nominal value 110   C The controller will  resume work when the motor temp is at 110 degrees inside  Range  60 170     5 Line Hall Zero It is only useful when the speed sensor is at 4    Zero Crossing point of Sine Cosine linear hall sensors output signal Usually the Sine Cosine  speed sensor supplier provided sensors with 2 5V or 3 0V zero crossing point    You can change it back between 2 5V and 3 0V if the motor can not run    Suggestion  Set according to the practical situation  factory default is 613 3 0V  for Mars  1114 1115 1302 1304 from Motenergy company 
17. hat the motor is connected before trying to run Identification angle  function in the configuration software The controller needs to be connected to  batteries motor and throttle before Identification operation That is to say  it is  not enough to connect only power supply PWR pin7  to batteries for    Identification Angle operation       Configuration software will be regularly updated and published on the website  Please  Update your Configuration Software regularly  You must uninstall the older version  before updating     Please try to use Identify function for motor and hall sensors in the user program          Table 1  ERROR CODES    Buzzer Error Codes       Code    Explanation    Solution       1 1     el    a    Automatic error  identification    1     Wrong wiring of motor phase line or hall   Please suspend the motor when enable  Auto Identify function        1 2    aa    Over voltage error    Battery voltage is too high for the controller   Check battery volts and configuration   Regeneration over voltage  Controller will have  cut back or stopped regen    This only accurate to   2  upon Overvoltage  setting           1 3       aaa    Low voltage error          The controller will clear after 5 seconds if battery  volts returns to normal   Check battery volts 8 recharge if required           21    Kelly KLS80801 1PS Sinusoidal Brushless Motor Controller User s Manual                                              over temperature       1 4 le auna  Over temperature 1
18. ing and Installation  3 1 Mounting the Controller    The controller can be oriented in any position which should be as clean and dry as possible   and if necessary  shielded with a cover to protect it from water and contaminants    To ensure full rated output power  the controller should be fastened to a clean  flat metal  surface with four screws  Applying silicon grease or some other thermal conductive material to  contact surface will enhance thermal performance    Proper heat sinking and airflow are vital to achieve the full power capability of the controller    The case outline and mounting holes  dimensions are shown in Figure 1                                      Figure 1 KLS8080I IPS mounting holes    dimensions  dimensions in millimeters     Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    3 2 Connections  3 2 1 Pin definition of KLS8080I IPS Controller    Orange  REV_SW  14    DJ7091Y 2 3 21    DJ7061Y 2 3 21    1 The switch signal is valid to 12V  2 12V only can be used for LED or Switch signals       Figure 2 KLS8080  waterproof connector  DJ7091Y 2 3 11 Pin Definition     14  REV_SW  Reverse switch input  Orange    6  RTN  Signal return or power supply return  Black   12  FWD  Forward switch White    11  12V 12V Source Red    25  12V brake switch  Yellowish    9  Relay  Main contactor driver  Blue   33 CAN H Green    7  PWR  Controller power supply  input   Pink   34 CAN L Dark Gray    Kelly KLS8080I IPS Sinusoidal Brushless Mot
19. ion  Set according to the practical situation  factory default is Enable      17 Brake H Pedal Releasing Brake High Pedal Disable   Value range  Enable and Disable   Functional description  If enabled  the controller will detect the current pedal status when  release the brake  If throttle got effective output  the controller will report fault and not operate   Suggestion  Set according to the practical situation  factory default is Disable      18 NTL H Pedal Neutral position High Pedal Disable Only useful when Three gears switch  function is enabled    If enable the controller will detect the current pedal position or signal When the switch is in  neutral poistion    If the throttle got effective output signal the controller will not operate and report fault code   Suggestion  Set according to the practical situation  factory default is Disable      19 Joystick function    If enable the controller can drive the motor on two directions without using any reversing switch   Just one single throttle can drive the motor on forward and reversing direction    The stick shift throttle firmware can be called wig wag or joystick operation It is only a software  function Usually It is useful for electric boat project You still can use the common 0 5K pot or  0 5V throttle for the controller lf you don t choose the joystick you operated the throttle in this  way The motor speed will increase when the throttle is from OV to 5V    If you enable joystick for this controller in user progra
20. m you will start the motor from 2 5V  position 2 6V to 5V is forward 2 4V to OV is backward    2 4V to 2 6V is the throttle dead zone Customers can adjust the throttle dead zone in user  program also    Please note the common throttle will spring back to original position if you release the throttle   Suggestion factory default is Disable      20 Three Gears switch It is used for function of F N R control    Please check the wiring diagram in the manual for F N R control    Suggestion  Set according to the practical situation  factory default is Disable     20 A Three Gears Switch   Value range  Enable and Disable   Functional description  If enabled  the Forward switch will be activated  Please see figure 4 1   Suggestion  Set according to the practical situation  factory default is Disable     20 B Foot Switch   Value range  Enable and Disable   Functional description  If enabled the foot switch will be activated The controller will not accept  the throttle signal if the foot switch is turned off  Please see figure 4 1    Suggestion  Set according to the practical situation  factory default is Disable     16       Kelly KLS80801 1PS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02                                                          Configuration Pin Status Runnin  Forward Foot Switch a Se N Foot P  Switch  12   14   15    OFF OFF x Neutral  OFF ON X Reverse  Enable Disable ON OFF X Forward  ON ON xX Neutral   x OFF OFF Can t operate   l X ON OFF Can t opera
21. nt  Phase Current Percent  Range  20 100  Functional description  The max motor current is  The Value   Peak Current of the Controller    Suggestion  Factory default is 100       4 Battery Limit  Battery Limit Current  Limit the max value of Battery Current  Range  20 100  Functional description  Set max battery current so as to protect battery  A lower value means a  lower battery output current and better protective effect  But excessively low value will affect  acceleration    Suggestion  Factory default is 100       5 Identification Angle  Please download the instruction to how to use Identification angle  function from the website    www kellycontroller com support php   If you can read 85 in Identification Angle item that is to say the system is stable and  normal Please fill in 170 for Identification Angle item in user program Then   please click Write button in user program Please wait a few seconds before restart the power  supply You will see some info on Monitor screen after power supply is   reset lf you see Reset error on the Monitor screen that is to say the auto_Identification is  finished You can see 85 in the Identification Angle item again And the controller will   blink error code This is normal Please reset the power supply again Then everything will be  fine The motor is ready to be drived by the KLS controller    Range  85 or 170 nothing else      6 TPS Low Err  Hall active pedal  if lower than the value  report the fault of TPS Type  Range   0 20    7 T
22. or Controller User s Manual    DJ7091Y 2 3 21 Pin Definition     15  Micro_SW  Throttle switch input  Gray    3  Throttle  Throttle analog input  0 5V  Dark Green   1  Temp  Motor temperature sensor input  Raddle    20  RTN  Signal return  Black    8  Meter  Copy signal of hall sensors  Dark Blue   4  5V  5V supply output   lt 40mA  Purple    2  BOOST  Boost function  Brown    DJ7061Y 2 3 21 Pin Definition     21  RTN Signal return  Black   5  5V  5V supply output  lt 40mA Purple     18  Hall A  Hall phase A  Yellow  This is Sine signal input on KLS8080IPS     17  Hall B  Hall phase B  Dark Green  This is Cosine signal input on KLS8080IPS    16  Hall C  Hall phase C  Dark Blue  There is no hall C signal input on KLS8080IPS     V 1 5 02          Notes   1  All RTN pins are internally connected   2  Meter function is to copy either of hall sensors   3  Switch to 12V is active  Open switch is inactive   Caution       Do not apply power until you are certain the controller wiring is correct and has been    double checked  Wiring faults will damage the controller       Ensure that the B  wiring is securely and properly connected before applying power     The preferred connection of the system contactor or circuit breaker is in series with the B     line       All contactors or circuit breakers in the B  line must have precharge resistors across their  contacts  Lack of even one of these precharge resistors may severely damage the controller    at switch on           Kelly KLS8080I
23. rake Yellowish A   Brake Switch Pog ES E    1 The switch signal is valid to 12V  2 12V only can be used for LED or Switch signals       Figure 4  KLS8080IPS controller standard wiring    10    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    3 2 3 Optional wiring of KLS8080I IPS controller  The 12V input signal of the pin supplies the second braking function of the controller     Brake Switch 12V   pin25 Brk sy 12V supply      From Controller  RTN 12V supply      Figure 5  Wiring of brake switch 12V   12V is provided by external source     Brake Switch 12V   pin25 Brk        From Controller  inl1l 12V    Figure 6  Wiring of brake switch 12V   12V is provided by KLS8080I controller on pin11    KTY84 130    pinl Motor_ Temp       From Controller    pin6 RTN       Figure 7  Wiring diagram for motor temperature sensor    NOTE The motor temperature sensor and brake switch used the same I O port on pin1 Both  functions can not be used at the same time KLS controller can support KTY84 150 and  KTY84 130 thermistors     11    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    3 2 4 Communication Port    A 4pin connector to RS232 port is provided to communicate with host computer for calibration and  configuration           O O GO O O 6 O    Oo 0 O                   Figure 8  RS232 Interface on 4pin connector to RS232 converter                   SM 4P Female     Figure 9  SM 4P connector for communication interface on K
24. roduce 0 5V signal     Main Contactor Coil Driver lt 2A     Full Power Operating Temperature Range  0 C to 70 C MOSFET temperature       Operating Temperature Range   40 Cto 100  C  MOSFET temperature       Motor Current Limit  1 minute  400A   700A  depending on the model    e Motor Current Limit  continuous  200A   300A  depending on the model     Max Battery Current  Configurable     2 4 Name Regulation    The name regulation of Kelly KLS motor controllers     KLS 80801 IPS   KLS Kelly BLDC motor controller based on sinusoidal waveform KLS8080I is supposed  to work with brushless motor with three hall sensors while KLS8080IPS can work with  Sin Cosin speed sensors There are  5V Sin Cosin and GND I O ports for brushless motor  with Sin Cosin speed sensors    I KLS8080I is designed by opto isolated technology We specify 8 30V for power supply  which must be isolated from main battery pack B  B         Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller                                        10 seconds Continuous  MORRI Current Amp  Current Amp  voltage Vol   KLS72501 8080I IPS 500 200 24 72  KLS72601 8080I IPS 600 240 24 72  KLS72701 8080I IPS 700 280 24 72  KLS96501 8080I IPS 500 200 24 96  KLS96601 8080I IPS 600 240 24 96  KLS12401 8080I IPS 400 160 24 120  KLS12601 8080I IPS 600 240 24 120  KLS14201 8080I IPS 200 80 24 144  KLS14301 8080I IPS 300 120 24 144                Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    Chapter 3 Wir
25. t  To avoid physically stressing  the bus bars use two  well insulated wrenches     5 2 Configuration    You can configure the controller with a host computer through either an RS232 or USB port    e     Disconnect motor wiring from controller for configuring existing parameters in the user  program or Android APP  If this operation is too much extra job for you  please make sure  the motor must be stopped before programming    e The controller may display fault code  but it doesn t affect programming or  configuration But it will affect the Identification angle operation Please try to eliminate the    20    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual    error codes before Identification angle operation   Use a straight through RS232 cable or USB converter provided by Kelly to connect to a  host computer  Provide  gt  18V to PWR  for a 24V controller  provide  gt  8V    Wire power  supply return supply negative  to any RTN pin   KLS controller requires a 4pin connector to Kelly RS232 Converter to support the  communication And customers may need a Z TEK USB cable for Tablet with Android OS     V 1 5 02    Customers may download PC software or Android APP to program the controller  before running the motor You may do Identification angle for brushless motor with  hall sensors after running the software or Android APP Every item in the  configuration program can show the explanation automatically when you click it           Caution      Make certain t
26. te  Disable Enable y ON ON Reverse  X OFF ON Forward    x OFF Xx Forward  Disable Disable ON x Reverse   Note  X means can be on or off  Figure 4 2     21 Boost If enabled the controller will output max power for a while    Boost function is just full throttle position when you turn on boost switch even if the throttle is not  operated at all    The boost function is still based on limiting of the motor current and battery current settings in  user program    Suggestion  Set according to the practical situation  factory default is Disable      22 Foot switch lt is used for microswitch lf enabled the controller will only accept the throttle  signal after received the valid foot switch signal    If there is no foot switch signal the controller will ignore the throttle signal    Suggestion  Set according to the practical situation  factory default is Disable      23 Cruise Control Value range  Enable and Disable   If enable if you hold throttle at certain position about 3 4 seconds the controller will get into  Cruise control    Release throttle and turn the throttle again or turn on the brake switch will make the Cruise  control quit    Suggestion factory default is Disable      24 Change Direction   If the direction is not what you expected after finish the Identification angle operation please just  choose Change Direction item   Please click Write button to activate Change Direction function  The motor direction will be what  you expected after the power supply is reset   Su
27. ve starting point  Suggestion  Set according to the practical situation  factory default is 20  5V 1 0V      10 TPS Dead High  TPS Dead Zone High  Range  60 95  Functional description  Set throttle effective ending point  Suggestion  Set according to the practical situation  factory default is 80  5V 4 0V      11 Max output Fre  Max output frequency  Unit Hz   Functional description It will affect the top speed of the motor    Suggestion  Set according to the practical situation  factory default is 1000Hz Please don t set it  1000HZz above      12 Max Speed  Max Speed  rpm   Range  0 10000 By default it is set at 4000      13 Max Fwd Speed    The forward speed of the percentage of maximum speed  Range   20 100 By default it is set at 100      14 Max Rev Speed    The reverse speed of the percentage of maximum speed  Range   20 100 By default it is set at 100      15 PWM Frequency  Frequency of PWM operation  Unit KHz   Functional description 20KHz is better for hub motor with strict quiet control    Suggestion  Set according to the practical situation  factory default is 20KHz Please don t set it  20KHz above    Value Range 10KHz or 20KHz     16 Start up H Pedal   Value range  Enable and Disable    15    Kelly KLS8080I IPS Sinusoidal Brushless Motor Controller User s Manual V 1 5 02    Functional description  If enabled  the controller will detect the current pedal status at power up   If throttle got effective output  the controller will report fault and not operate   Suggest
    