1. mains defective after the second attempt to repair or replace the product or it is econo mically unfeasible to repair or replace the product the customer has the right to can cel the order contract or reduce payment accordingly KESSEL must be notified im mediately in writing of defects in a product In the case that the defect is not visible or difficult to detect KESSEL must be notified immediately in writing of the defect as soon as it is discovered If the product is repaired or replaced the newly repaired or replaced product shall receive a new warranty iden tical to that which the original defective product was granted The term defective ur KESSEL product refers only to the product or part needing repair or replacement and not ne cessarily to the entire product or unit KES SEL products are warranted for a period of 24 month This warranty period begins on the day the product is shipped form KES SEL to its customer The warranty only ap plies to newly manufactured products Ad ditional information can be found in section 377 of the HGB In addition to the standard warranty KESSEL offers an additional 20 year warranty on the polymer bodies of class II fuel separators grease separa tors inspection chambers wastewater treatment systems and rainwater storage tanks This additional warranty applies to the watertightness usability and structural soundness of the product 10 A requirement of this additio
2. and the safety lock A locked into place Ill 12 To close the closure valve first lower the sa fety lock A 90 degrees to the horizontal po sition Illustration 13 Number 1 Now push down the red closure handle Number 2 a twisting motion while pus hing down the red handle makes this ea sier Once in the down position the red clo sure handle should be turned in the clock wise direction Ill 14 Number 4 so that the base of the handle is securely locked in the recessed plastic holders The closure valve now is in the closed shut off position Ill 15 To open the closure valve perform the above steps in the reverse order Once open it should be checked that the red clo sure handle is in the fully up position and that the safety lock is re clipped into place to assure that the closure handle is not un intentionally closed 6 Inspektion und Wartung During inspection and maintenance of the Aquailift F Lifting Station the closure valve should also be inspected and serviced if re quired In the closed position no more than j liter of water should pass through the clo sure lock within a period of 15 minutes Note Disassembling the closure valve is not allowed Defective parts should be re placed with only original KESSEL replace ment parts 7 Warranty 1 In the case that a KESSEL product is de fective KESSEL has the option of repairing or replacing the product If the product re
3. INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS KESSEL Closure Valve for KESSEL Aqualift F lifting stations for wastewater with or without sewage Order Nr 28 683 28 694 Product Advantages E Quick installation E Rotatable outlet connection m Easy operation E High pressure resistance O Installation C Service of this unit should be carried out by a licensed professional mK KESSEL Edition 08 2011 ID Number 240 060 Subject to technical amendments Name Sign Company stamp Safety Instructions This instruction handbook contains important security advices which must be followed at all times during installation operation maintenance and repair of the power unit The security advices are labelled as follows AN General warning sign according to ISO 3864 B 3 1 tagging endangering of persons AN Warning sign according ISO 3864 B 3 6 to caution against voltage J This word indicates security advices disregarding these will cause severe danger for the station and it s function This instruction handbook must be available at all times in the station Dear customer We are happy you decided to choose a product made by KESSEL Before leaving the factory the whole station has been subject to a strict quality control However we kindly ask you to check whether the station has been delivered completely and without any damage In case of transport damage please look for the regulations in ch
4. apter guarantee of this instruction Prior to installation and putting into operation of the Aqualift it is in your interest and essential that you carefully read and follow the installation operation maintenance and repair instructions KESSEL AG UK KESSEL Ble e mere oh t ala 1 Safety Instructions 2 General 3 Technical Data 4 Installation and Assembly 5 Operation 6 Inspection and Maintenance 7 Replacement parts 8 Warranty PPE E A E AA E E E A E A Page 2 E E E E A E Page 4 E EA E E E EE E Page 5 E PA E P E P E O E E E Page 7 PAPOEA E AET OE E TA eee Page 10 E E E E E eae eceasaeeeeeee Page 11 OEE OTA O E O E O E O Page 12 E PAO E ONAA E PE E P E AA E E Page 14 ik KESSEL The KESSEL closure valve is available se parately as an accessory or may be already integrated ina KESSEL Aqualift F lifting sta tion for wastewater with or without sewage The lifting station should be installed in frost and weather protected rooms The closure valve consists of the following operational elements see Illustration 1 Operating handle Safety lock DN 100 outlet ill 1 ur KESSEL Closure valve dimensions Inin order for the KESSEL closure valve to operate properly it should only be connec ted to the appropriate KESSEL lifting stati on the appropriate lifting stations are list in the Installation and Assembly portion of this manual If the closure valve is
5. clo sure valve has been installed it should be connected or reconnected to the pressure pi ping be sure that all gaskets are seated properly In order to better meet on site requirements the closure valve is rotatable in 45 degree in crements Illustration 9 ill 9 ATTENTION gt gt The T section on twin pump lifting stati ons should only be installed in the ver tical position see Illustrations 6 and 8 Installing the closure valve in a non ver tical position makes it impossible to firmly secure the fastening bolts which could result in a non water tight connec tion gt The connection from the closure valve s outlet to the on site pressure drainage pipe should only be done with the inclu ded flexible hose connector see lifting station installation and operation ma nual ur KESSEL 4 Installation and Assembly After the closure valve has been installed on a single or twin pump KESSEL Aqualift F Lifting Station it should look like one one of the units shown below ill 10 iki KESSEL 5 Operation The closure valve makes it possible to ea sily close off the outlet pressure pipe before doing any type of service work on the lifting station for example servicing cleanign the integrated non return flap inside the lif ting station s outlet During normal lifting station operation the closure valve should be in the open positi on red handle B in the up position
6. nal warranty is that the product is properly installed and operated in accordance with the valid in stallation and user s manual as well as the corresponding norms regulations 2 Wear and tear on a product will not be con sidered a defect Problems with products resulting from improper installation hand ling or maintenance will also not be consi dered a defect Note Only the manufacturer may open sea led components or screw connections Otherwise the warranty may become null and void 01 06 2010 Replacement Parts Pos Nr Amount Article Number Description 1 1 240 053 90 degree outlet housing DN 100 2 1 240 035 Closure assembly 3 1 240 027 O ring 4 4 240 058 Securing bolts M6 5 4 240 059 Securing nuts M6 Connection with lifting station Pos Nr Amount Article Number Description 6 1 240 037 O ring 7 8 240 038 Securing bolts M8 8 8 240 039 Securing nuts M8 11 AC KESSEL d Backwater protection _ Lifting Stations and pumps _ Drains and shower channels _ Separators Grease Separators Oil Fuel Coalescence Separators Starch Separators Sediment Separators _ Septic Systems _ Inspection Chambers _ Rainwater Management Systems iki KESSEL
7. to be used on different pumps then additional parts are required If this is the case the in stallation company is responsible for proper installation of the closure valve Excessive force should not be applied to the closure valve such as using it as a step Damage occuring to the closure valve from impropery installation operation or use are not covered under this products warranty 3 Technical Data KESSEL Closure Valve dimension installed on an KESSEL Aqualift F lifting station ll 3 shows a single pumpAqualifte F ll 4 shows a twin pump Aqualift F ur KESSEL 3 Technical Data A licensed installation company should in For models up to and incl May 2009 stall the closure valve on the Aqualift F lifting station Insallation requires the following gt Disconnecting the Aqualift F lifting station from its power source gt Assuring that no wastewater enters the lif ting station during installation all drainage fixtures connected to the lifting station must not be used or operated gt During installation workers should wear protective clothing to prevent bodily con tamination with the septic wastewater Smoking eating or drinking during instal For models beginning lation is not allowed June 2009 ill 6 ur KESSEL ill 8 Safety bolts Safety bolts 4 Installation and Assembly Gaskets should be properly lubricated befo re the closure valve is installed Once the

Download Pdf Manuals

image

Related Search

Related Contents

Fisher FIELDVUEt DVC6000 SIS Series Digital  Licensing Information User Manual Sun Server X4-8  Ultra Products ULT31354 User's Manual  manuel d`installation indicateurs pèse-camions bin  Genre Vascellum - Société Mycologique des Hautes Vosges  Sony XR-3500MK2 User's Manual  OWNERS OPERATING & SAFETY MANUAL PRINCIPLE OF PUMP  TOPO Deutschland für GARMIN GPS  東京歯科大学同窓会会報  Nokia N82 2.4" 114g  