1. User friendly sealed keypad allows easy digital setting on running time speed and optimum temperature condition Large easy to read LCD display presents a menu of functional readouts Automatic shutoff at end of study via electronic timer adjustable from 1 minute to 500 hours 8 Automatic shutoff of shaker when lid is opened which ensures operator safety Non volatile memory retains setpoints during a power failure and restarts shaker automatically Alarms programmed to warn of setpoints deviation and to indicate when timer operation has expired A high volume air circulation system maintains optimum temperature uniformity as well as providing maximum oxygen transfer See through chamber door provides complete visibility and minimize the need to open the chamber frequently Mirror finished stainless steel interior provides excellent durability and an easy to clean surface Laboratory Equipment Pty Ltd 2 LEVEL INCUBATOR SHAKER 2013 VERI1 01 3 Control Panel Timer LED display Alarm Temperature ThCkeENnG Increase Speed Decrease Start Pause AKIN Heating Power Refrigeration on off Cooling SetiConfirmation 4 Starting the Unit Turn on the power to the unit by pressing the Main Switch located on the right side of the unit body the unit enters into the running mode All keys on the control panel are activated in the running mode The LED Display shows the preset temperature speed t
2. LEVEL INCUBATOR SHAKER 2013 VER1 01 9 Defrosting Operation the unit at a low temperature for a long period of time causes the buildup of frost which degrades the freezing performance and may disable the temperature from being controlled at the setpoint The defrosting function guarantees the unit to operate smoothly and continuously in such a case Defrosting function is set via the following steps e First press the Set Confirmation key then press the Increase key to enter the password 9 Press the Refrigeration key the unit enters into refrigeration mode first stage e Press the Refrigeration key again the unit enters into defrosting timer setting mode second stage Defrosting timer value can be set via the Increase Decrease key e Press the Refrigeration key once more the unit enters into defrosting time period setting mode Defrosting time period can be set via the Increase Decrease key e To confirm the new setting press the Set Confirmation key Defrosting Timer Setting refers to the function by which the unit starts defrosting every given time period For example if the defrosting timer value is set at 1 the unit starts defrosting every 1 hour If the defrost timer value is set at 2 the unit starts defrosting every 2 hour However if the defrost timer value is set at 0 the unit does not start defrosting at all Defrosting Time Period refers to the time span from the moment the unit starts defrosting till it exits defro
3. ABEC INSTRUCTION MANUAL JABEC Laboratory Equipment Pty Ltd a amp amp amp amp s Laboratory Equipment Pty Ltd email sales labec com au Ph 02 9560 2811 lt Fax 02 9560 6131 wwvw labec com au LABORATORY EQUIPMENT PTY LTD WWW LABEC COM AU TWO LEVEL INCUBATOR SHAKER USER S MANUAL Content Safety Instructions Description Control Panel Starting the Unit Temperature Control Overtemperature Alarm Speed Control Timer Function Defrosting 10 Non volatile Memory 11 Technical Specifications 12 Trouble shooting 13 Packing List OONDOARWN Laboratory Equipment Pty Ltd 2 LEVEL INCUBATOR SHAKER 2013 VER1 01 Thank you very much for choosing ZHWY 2102 2112 series Two Layers Incubator Shakers To ensure a smooth operation of this unit we would like to ask you to read this instruction manual thoroughly and always operate the machine as guided by this manual Also keep this manual with the unit for maintenance reference In case you meet problems with this unit please feel free to contact Laboratory Equipment Pty Ltd We will help you identify the problem and provide trouble shooting service for you 1 Safety Instructions 1 The unit must be properly wired to ensure safety either to the operator or facilities It is recommended to use dedicated line to avoid interference from other equipment 2 Please verify the local electric power supply is in accordance with the elec
4. and Refrigerated Ambient 20 C to 60 C Ambient 20 C to 60 C Range Set Division Uniformity 1rpm 1rpm 1rpm 1rpm 0 500 hours 0 500 hours 0 500 hours 0 500 hours Capacity 50mlx90 or 50mlx48 or 50m1x154 or 50m1x154 or 100mIx90 or 100mIx48 or 100mIx154 or 100mIx154 or 250mIx56 or 250mIx30 or 250mIx90 or 250mIx90 or 500mI x48 or 500mI x24 or 500mI x70 or 500mI x70 or 750mIx36 or 750mIx18 750mIx56 or 750mIx56 or 1000mIx30 1000mIx36 1000mIx36 Platform Size 134x458 mm 500x350 mm 970x560 mm 940x580 mm Overall Size 700x590x1230 950x 710x1250 1200x820x1600 1200x820x1600 rots wad mm mn Requirement Weight 235Kg 150Kg 456Kg A86Kg 1 year Laboratory Equipment Pty Ltd 2 LEVEL INCUBATOR SHAKER 2013 VER1 01 12 Trouble Shooting Problem Description Possible Causes Non running of unit no Failure of power supply Proper wiring Solitons aca the unit display of LED indicator Damage of fuse Replace the fuse however the unit is running from other equipments unit temperatures correctly set Measured temperature is Preset temperature value too Remove the wind inlet above preset value high cover at the back of the Frequent overtemperature unit or set the alarming refrigeration value to 0 5 Unit is not placed on flat floor Place the unit on flat floor the platform clamps 13 Packing List Upon receipt of the unit examine if there 1s any damage done to the unit during transportation In the event of shipping
5. damage a claim must be filed with the transportation carrier within 7 days of receipt Remove the packing material from the box take care that the accessories are not thrown away with the packing material Lift the unit out of the box Do not lift the unit by the door handle Check all the items have been received Included in the box should be the following Fuss oS Fuse Tool for changing platforms Water tray Instruction Manual Laboratory Equipment Pty Ltd 2 LEVEL INCUBATOR SHAKER 2013 VER1 01
6. imer and finally measured temperature Press the Start Pause key the unit will operate on the preset parameters Second press the Start Pause key while the unit is running stops the operation Holding the Power On Off key for more than 3 seconds the unit is powered off 5 Temperature Control Temperature of the unit can be set from ambient 20 C to 60 C Temperature setting 1s completed by the following steps l Press the Set Confirmation key then press the Increase key to enter the password 3 2 Press the Temperature key the unit enters into temperature setting mode Temperature value can be set via the Increase Decrease key To confirm the new setting press the Set Confirmation key Setting of a new value overwrites the old value in the memory Laboratory Equipment Pty Ltd 2 LEVEL INCUBATOR SHAKER 2013 VERI1 01 Refrigeration Press the Set Confirmation key then press the Increase key to enter the password 9 Press the Refrigeration key the unit enters into refrigeration setting mode Refrigeration parameter can be set via the Increase Decrease key To confirm the new setting press the Set Confirmation key e If the unit is to be used in the temperature range of ambient 5 C to ambient 5 C the refrigeration parameter can be set at the value 0 2 e If the unit is to be used in the temperature range of ambient 20 C to ambient 5 C the refrigeration parameter can be set at the value 0 5 e If the unit is to be used in
7. sting mode For example if the defrosting time period is set at 1 the unit will defrost for 1 minute If the defrosting time period is set at 2 the unit will defrost for 2 minutes Due to the specific application conditions the defrosting timer value and defrosting time period may vary greatly However the following values can be viewed as a starting point or general rule Defrosting Timer Value 6 Defrosting Time Period 3 If the above values are set the unit will defrost for 3 minutes every 6 hours under refrigerated operation During defrosting the water tray enclosed in the package must be taken out for fetching the melted water Laboratory Equipment Pty Ltd 2 LEVEL INCUBATOR SHAKER 2013 VER1 01 10 Non volatile Memory Function Non volatile memory retains parameters during a power interrupt and restarts the incubator shaker automatically Non volatile Memory Function can be set by the following steps l First press the Set Confirmation key then press the Increase key to enter the password 5 2 Press the Timer key the unit enters into non volatile memory setting mode The LED indicator displays ON OFF options 3 Press the Increase Decrease key to choose between ON and OFF When ON is selected the non volatile memory function is started When Off is selected the memory function is canceled 11 Technical Specifications ltem Incubator Incubator Incubator Incubator Shaker Shaker Shaker Shaker ZHWY 2112B Heated
8. temperature recovery 14 The unit must be kept away from volatile flammable explosive liquids or gases This may cause damages either to the unit or property losses includes facilities and buildings 15 Incase of malfunction or burning smell the unit must be immediately ceased for checking 16 Ifa thunderstorm approaches in the distance immediately turn off the power Lightning from the storm may cause fire or electrical shock 17 The above safety instructions must be followed during the operation of the unit All persons operating this unit should review this manual No compensation or claim can be made against the manufacturer if damage is caused to the personnel or facilities that result from the improper use of this unit Laboratory Equipment Pty Ltd 2 LEVEL INCUBATOR SHAKER 2013 VER1 01 2 Unit Description ZHWY 2102 2112 series Two Layers Incubator Shakers are designed for large capacity growth of biological organisms under optimum conditions of temperature time and agitation These microprocessor controlled incubator shakers offer a number of advanced features include user friendly digital setpoints keypad overtemperature alarm and self correcting feedback controls on temperature and shaking speed Features in Summary Powerful triple eccentric drive mechanism guarantees a lifetime of smooth and continuous shaking motion lt A PID microprocessor controller maintains precise temperature and shaking speed
9. the temperature range of ambient S5 C to 60 C the refrigeration parameter can be set at the value 2 The refrigeration is cancelled 6 Overtemperature Alarm In case the gap between measured temperature and setting temperature excels 3 C the unit sends out audible and visible alarm automatically and the yellow alarm indicator flashes The platform keeps on shaking while the heating or refrigeration stops Press the Temperature key will cancel the alarm for 30 minutes Reset the temperature value the unit exits the alarm mode 7 Speed Control To set the desired shaking speed first press the Set Confirmation key then press the Increase key to enter the password 3 Press the Speed key the unit enters into speed setting mode The desired speed value can be set via the Increase Decrease key To confirm the new setting press the Set Confirmation key Setting of a new value overwrites the old value in the memory 8 Timer When timer function is needed first press the Set Confirmation key then press the Increase key to enter the password 3 Press the Timer key the unit enters into timer setting mode the desired timer value can be set via the Increase Decrease key To confirm the new setting press the Set Confirmation key By the time the remaining time reaches 0 00 the platform stops shaking the unit sends out audible and visible alarm for 2 minutes Press the Timer key the alarm will be muted Laboratory Equipment Pty Ltd 2
10. trical requirement 240V 50 60Hz of the unit 3 Do not use extra power cords or lines for this unit do not bend entangle or twist the power cord or apply excessive tension to it otherwise it may cause damage to the unit or result in electrical shock or fire 4 Do not touch the unit with wet hands or insert other items into the wind inlet when the unit is running It may cause a fire or electrical shock 5 Do not move the unit when it is operating 6 Incase moving the unit is necessary please be sure the unit is kept upright Otherwise it may cause damage to the refrigeration system inside 7 Itis good practice to ensure that the shaking platform comes to a complete standstill before open the door of the chamber 8 When opening or closing the chamber door please handle with care do not use too much force 9 Incase fuse has to be replaced the electric power supply has to be cut off 10 The unit must be placed on solid flat floors near a grounded electrical outlet allow sufficient clearance on all sides of the unit at least 20cm for proper ventilation Avoid locations under direct sunlight or near heat producing equipments such as an oven 11 After continuous refrigeration for 10 days it is good practice to de damp the unit by turning on the heating function 12 Regular check to the flask clamps is necessary to ensure they are in good status 13 Frequent opening of the chamber door is not recommended as this may affect the