Home
ART. DT12EAM
Contents
1. e Microwave element A MW antenna swt FACTORY SETTING DP2 N e N 12 p SW1 e MW sensitivity 2 swi S SW DIP 2 N e A 1 Anti mask module connector e SW2 FACTORY SETTING PIR sensor Q go 1234 L APP PIR sensitivity SW2 SW DIP 4 DM 93S 1P CO JEBUG UART 4 J8 RI ik R18 48k R20 1K P2 61K R23 ABK eee oooa EEE X6 HEADER 2X4 HEADER 2X2 HEADER 2X4 HEADER 2X4 J9 BLOCK 10 TAMPER TEOL AM FAI ALARM TEST 12V 2 Detection Pattern The DT12EAM has a 90 top view PIR and MW detection pattern with 12m detection distance when installed at 2 4m above the ground surface DT12EAM TOP VIEW SIDE VIEW 3 Selecting mounting location Avoid the following Installation Locations other microwave detectors as well as systems of anti intrusion surveillance The bracket provides DT12EAM installation on a wall The wall should be leveled Choose a location most likely to intercept an intruder according to detection pattern on page 5 The installation of the DT12bEAM requires straight and solid base for the dete
2. ART DI12EAM Dual Tech Sensor Antimask function USER MANUAL amp Cornelit Passion 1 on Technology Design Features Microwave detection based on Doppler concept N O relays switched at the same time Installation height is calibration free from 1 8m to 2 4m 5 9 to 7 8 ft PIR sensitivity adjustment MW intensity selection Temperature compensation Microcontroller signal processing Anti mask mechanism for PIR lens Front and back tamper protection Unique waterproof and sealed plastic design Detection Range 12m Detects human intruders walking or running No maintenance required High RFI EMI Immunity Protection from direct sunlight wind up to 30 m sec snow and rain small animals removal of top cover and removal from mounting bracket Assembly description The DT12EAM is a robust yet small detector which includes a large LED indicator that can be easily observed from long distances to provide indication of intrusion Using the supplied mounting bracket the DT12EAM can be easily mounted to walls using the provided mounting screws For installations requiring the detection beam to be adjusted horizontally or vertically to obtain the desired field of protection use the Outdoor Mounting Bracket pictured below not included DT12EAM Outdoor Motion Detector Outdoor Mounting Bracket The DI12EAM consists of two detection elements e PIR element
3. WIN J6 AM TROUBLE J6 AM TROUBLE J 6 8 2 4 Connessione interna tra FOUT e TIN 8 2 4 J8 2 4 Connessione interna tra AOUT e FIN J8 2 4 Connessione interna tra AOUT e TIN J8 2 4 Connessione interna tra AOUT FIN e FOUT TIN OO Terminal 1 Marked 12V Connect to a positive Voltage of 9 6 16Vdc source Usually from the alarm CP Terminal 2 Marked GND Connect to the ground of the CP Terminal 3 Marked Test 9 6 16 v on this pin will enter the DT12EAM to walk test mode even if SW2 position 1 is off Terminals 4 amp 5 Marked ALARM These are the output relay contacts of the detector Connect to a normally closed or normally opened zone in the control unit When an intruder is detected alarm relays N C and N O will switch for 1 8 sec Terminal 6 amp 7 Marked AM FAIL These are the output of the anti mask and Trouble relay N C and N O Will switch if one from the following scenario happens The supply voltage is under 8 5v Mask detection will restore if the mask is removed PIR or MW self test fail every 10 hours the detector made self test for PIR and MW Sensors Terminal 8 Marked TEOL End of line optional terminal for end of line resistors connections Terminals 10 amp 9 Marked TAMPER If a Tamper function is required connect these terminals to a 24 hour normally closed protective zone in the CP If the top cover of the detector is opene
4. 8 2 2 MW Sensitivity adjustment The MW has 4 configurable levels by SW1 Pomon fo High sensitivity more suitable for indoor application High sensitivity for outdoor application Medium sensitivity for outdoor application Low sensitivity for outdoor application Note This setting can affect the detection sensitivity of the infrared 8 3 Indications setting The DT12bEAM has 3 LEDs that each points at different indication 1 Green LED indicates PIR detection 2 Yellow LED indicates MW detection 3 Red LED alarm indication logic AND of both MW and PIR The installer has an option to control LEDs operation using the LED control on SW2 position 1 between ON and OFF Or by apply 9 6 16v to terminal block position 3 test e Place the top cover to the base and close it using the bottom screw 9 Anti mask The DT12bEAM has a sophisticate anti mask module P N3302196 A eo sad e Q e 38 e This module is assembled the 12 main board To activate the AM please pull up SW2 position 2 The DT12bEAM has aambient light sensor The DT12EAM made self calibration for the anti mask 30 minutes after power up Please be verify during installation that the DT12EAM is closed well before 30 minutes from power up If the first power up is under direct sunlight the DI 12EAM will made the self calibration 30 minutes after the sun light intensity will decrease 10 Oper
5. ation Note Connect the DT12EAM to a positive Voltage output of 9 6 16VDC Use only a listed power limited source The detector shall be provided with minimum of 4 hours of standby power from either a listed compatible control unit or power supply The detector is automatically operated once connected to power The LEDs start flashing one at a time side to side for 30 seconds during the warm up period and after that it will turn off At this time the detector is ready for operation 11 Test procedures Walk Test Make sure LEDs control is set to ON Allow 30 seconds of warm up time Make sure that the protected area is cleared of all people otart walking across the detection zone Look at the LEDs whenever motion is detected all LEDs are turned ON Allow 5 sec between each test for the detector to stabilize Upon installation the unit should be thoroughly tested to verify proper operation Walk across the entire area where coverage is desired Should the coverage be incomplete readjust sensitivity or relocate the detector Once coverage is as desired the LEDs may be disabled NOTE Walk Test procedure should be conducted at least once a year to confirm proper operation and coverage of the detector 12 Specifications Detection Method PIR AND MW 10 525GHz Microwave Frequency Power Input 9 6 to 16Vdc Active 24mA 5 Standby 21mA 5 Temp Compensation Dual slop temperature compensation Alar
6. ctor and setting of front panel against the center of protected area The protected area must be free from obstacles like walls fences trees ditches and Facing direct sunlight Facing areas subject to rapid temperature changes Mounted at more than 10 from the vertical or horizontal plane Facing metal doors Near direct sources of heat or airflow Clear all physical obstacles from the detection area e g plants laundry etc Clear all light reflecting surfaces from the detection area including puddles or other standing water Avoid installation on the following types of ground Thick vegetation Grass un mown Water Sand and Metal NOTES Hecommended installation height is 2 1m 6 8 ft The PIR sensor detects motion crossing the beam it is less sensitive detecting motion towards the detector The DT12EAM performs best when provided with a constant and stable environment In order to ensure suitable operation of the DT12bEAM the type of ground should be one of the following Asphalt concrete Cement Soil Clay Gravel or Grass mown 4 Detector Installation Important Prior to installation read both Operation and Selecting the mounting location sections carefully 1 Install the detector in such manner that the intruder is 2 The detector is to be installed at height of 1 8 to 2 4 most likely to cross the detection area from side to side meters 5 9 to 7 8 ft ideally 2 1m 6 8 ft
7. d or the detector is detached from installation wall an immediate alarm signal will be sent to the CP 6 Settings amp Adjustments 6 1 Detection beam direction The DT12bEAM detection beam direction is fixed As a result it is recommended to face the intrusion area with the detector 10 5 0 10 5 34 5ft 34 5ft 6 2 Sensitivity and Range Adjustment There are 2 options for PIR sensitivity option PIR potentiometer adjust oW position 3 PIR pulse setting when up 2 pulses down 3 pulses MW antenna FACTORY SETTING i O N e 12 S Z SW1 n MW sensitivity SW1 o e SW DIP 2 N e A 1 2 1 Anti mask module connector SW2 R PIR sensor FACTORY SETTING 1234 PIR sensitivity RI TR RIS R20 R21 1822 35 R16 17 ak 819 ga P1 ag AK 2 61K 5 48K ne 5 49014 on og HEADER 2X4 HEADER2X2 HEADER 2X4 lt HEADER 2X4 J9 BLOCK 10 TAMPER TEOL AM FAII ALARM TEST 12V General configuration setting table for sw2 On up Off down Indication LEDs Indication LEDs on Indication LEDs off 2 ON jOf Anti Mask Off 2 PIR pulse count Pet immunit Off
8. m Period 2 sec 0 5sec Form C NC NO Common Alarm Outputs 28Vdc 0 1 A with 10 Ohm Two Switches Current Draw Tamper Switch s N C 28Vdc 0 1 A with 10 Ohm Series protection resistors Opens when cover is removed from unit s base 10 V m plus 80 AM from 80 MHz to 2GHz mme IIR European directives RTTE EMC Low Voltage RoHS 47 CFR part 15 subpart C section 15 245 47CFR part 15 USA amp Canada subpart B RSS210 ICES 003 Protection Degree IEC 60529 IP 64 Specifications are subject to change without prior notice amp Cornelit Passion Technology Design
9. r1 1 8 2 4 meters 3 Make sure to attach the metal bracket to a leveled 4 Placing the detector on perpendicular wall is straight and firm wall leaving 10cm 3 9 inches from required for guarding a side window opening the top and 10cm 3 9 inches from both sides for easy Alternately the LC B1 15X Outdoor Mounting bracket installation and maintenance can be installed on the same wall allowing the detector beam to be rotated towards the window 6 Release the rear metal bracket by unwinding internal bottom screw 8 Attach the rear bracket to the wall using mounting 7 Release the detector body from the metal bracket by screws pulling the detector up and out 9 Insert wires through provided access hole and wiring 10 Attach the sealing sponge pad to the wire opening from the rear side after the wires have been connected and prior to final product affixing to the channels mounted bracket 11 Place the detector on the mounting bracket from top side down and then lock the screw at the bottom 5 Terminal Block Connections 8 Ooo 4 j HEADER 2X4 HEADER 2X 10 9 8 7 n k TIN TOUT FOUT FIN AOUT AIN TAMPER TEOL AM FAIL ALARM TEST 12V zi x HEADER 2X4 EST HEADER 2X4 JUMPER POSIZIONE VALORE RESISTENZA J5 EOL TAMPER 1 BK J5 EOL TAMPER 2 DIDNTUE X X J5 EOL TAMPER 3 J5 EOL TAMPER
Download Pdf Manuals
Related Search
Related Contents
Ginger 0310/PC Installation Guide どこ・イルカminiかんたん設定ガイド 701330 Rev C - Equine Full Leg Wrap Use Guide.ai Computer Gear 27-0052 power cable Gandhi Washington Method Support Tool User Manual Rosewill RX355-U User's Manual Instalación del hardware: Guía del usuario del Broadcom Gigabit Philips NTRX900 KitchenAid KFBP100LSS User's Manual Copyright © All rights reserved.