Home

AC890PX-M Modular Chassis AC Drives

image

Contents

1. No Enclosure Frame M only O No special option 1 Advanced High N gt 50 Hz 60 Hz None SinCos encoder Endat 2 1 Incremental quadrature encoder Resolver Resolver repeater Mark registration Endat 2 1 encoder NO GQ GM O None CANopen communications ControlINet communications DeviceNet communications Profibus communications Modbus TCP IP Ethernet IP Profinet Mark registration Endat 2 1 encoder RS485 communications Encoder with repeater output High Resolution Analogue Input Dm Gd TL d vVGaoazZzeo Not fitted Firewire 1394A CAN peer to peer communications Encoder with repeater output High Resolution Analogue Input 0 nmn s Ec AC890PX Modular Chassis Drive Packaged Drives Options Factory Supplied Packaged Drives Options Factory Supplied High Power Packaged AC Drives 110 kW 400 kw 500 kW AC890PX FASTPACK AC890PX FASTPACK Drive 110 400 kW In addition to being supplied in kit form AC890PX Modular Chassis drives can be supplied as a FASTPACK free standing drive complete with all neccessary anciliary components to enable control of either an AC induction or Permanent Magnet AC motor Designed as a simple replacement to star delta or soft start control of motors FASTPACK can be configured to deliver complete control in a ready to install IP33 or IP54 enclosure Control options such as operator keypad start stop pushbuttons
2. 19 AC890PX Modular Chassis Drive Accessories and Options Accessories and Options Communication Interfaces Supported Protocols Ethernet IP Communication Speed 10 100 Mbits s By Drive System Explorer software via RTNX protocol Suitable for firmware Version 3 2 Supported Protocols Modbus TCP Communication Speed 10 100 Mbits s epg By Drive System Explorer software via RTNX varn protocol _ Suitable for firmware Version 3 2 8903 DN 00 DeviceNet communication interface i Supports the group 2 only slave subset of the w DeviceNet protocol Communication Speed 125 k 250 k and 500 kbits s oe Dip switch or software setting of station address and network speed Supported Messages Polled I O Cyclic Outputs Change of State COS Explicit Messaging Suitable for firmware Version 1 9 Profile DS402 Communication Speed 20 k 50 k 125 k 250 k 500 k 1 Mbits s selectable by software or DIP switch setting Station Address DIP switch or software setting of station address and network speed Supported Messages SDO PDO NMT SYNC Suitable for firmware Version 1 3 8903 CN 00 ControINet communication interface Communication Speed Selectable by software or DIP switch setting Station Address Software setting of station address Supported Messages Polled UO Suitable for firmware Version 1 4 8903 PB 00 PROFIBUS DP communication
3. 100 mA per output directly as the speed setpoint for a fast response time In addition to this Analog Input the 8903 Al option provides an incremental encoder input as well as an incremental encoder output Resolution 15 bits sign bit The 8903 EP Encoder Option has the 11 V same functionalities of the 8903 AI Input Format ss TRES except for the analogue input Input Impedance 100 KQ Input Low Pass Filter 3 kHz Encoder Power Supply Maximum output current 100 mA per output High Resolution Analogue Input 8903 Al Only AC890PX Modular Chassis Drive Accessories and Options Anciliary Parts AC Input Chokes Parker s range of AC input chokes have been especially selected to match the requirements of the Parker AC drive range and are used to reduce the harmonic content of the supply current Nominal 400 VAC 110 100 C0O501691U411 132 90 CO501691U413 160 340 80 CO501691U416 200 425 55 COQO501691U420 250 535 45 C0O501691U425 280 600 40 C0O501691U428 315 680 35 C0O501691U431 For other voltages please contact your local sales office Output Chokes To limit capacitive currents and prevent nuisance tripping in installations with longer cable runs over 100 m a choke may be fitted to the drives output This limits the capacitive current and prevents overcurrent trips and excessive temperature rise in the motor These may be used with 380 460 V and 500 575 VAC drives Motor Choke Maximum Cu
4. Ireland Dublin Tel 353 0 1 466 6370 parker ireland parker com IT Italy Corsico MI Tel 39 02 45 19 21 parker italy parker com KZ Kazakhstan Almaty Tel 7 7272 505 800 parker easteurope parker com NL The Netherlands Oldenzaal Tel 31 0 541 585 000 parker nl parker com NO Norway Asker Tel 47 66 75 34 00 parker norway parker com PL Poland Warsaw Tel 48 0 22 573 24 00 parker poland parker com PT Portugal Leca da Palmeira Tel 351 22 999 7360 parker portugal parker com RO Romania Bucharest Tel 40 21 252 1382 parker romania parker com RU Russia Moscow Tel 7 495 645 2156 parker russia parker com SE Sweden Spanga Tel 46 0 8 59 79 50 00 parker sweden parker com SK Slovakia Bansk Bystrica Tel 421 484 162 252 parker slovakia parker com SL Slovenia Novo Mesto Tel 386 7 337 6650 parker slovenia parker com TR Turkey Istanbul Tel 90 216 4997081 parker turkey parker com UA Ukraine Kiev Tel 380 44 494 2731 parker ukraine parker com UK United Kingdom Warwick Tel 44 0 1926 317 878 parker uk parker com ZA South Africa Kempton Park Tel 27 0 11 961 0700 parker southafrica parker com We reserve the right to make technical changes The data correspond to the technical state at the time of printing 2012 Parker Hannifin Corporation All rights reserved EMEA Product Information Centre Free phone 00 800 27 27 5374 North A
5. emergency stops and output contactors can all be selected from a list of standard options to meet a host of control requirements from simple motor speed control to more complex applications AC890PX AC890PX Modular Air Cooled Parallel AC Drive Systems 400 900 kW For systems with higher power requirements up to 900 kW a maximum of three AC890PX Modular Chassis drives can be connected in parallel with the use of additional input and output chokes Parker is able to offer this solution as a turnkey fully integrated drive system with all necessary anciliary control hardware and software Alternatively a simple freestanding drive with or without AFE can be supplied up to 900 kW With cooling designed to meet specific requirements we can offer any number of cooling methods including chillers air water heat exchangers force natural ventilation or water cooling AC890PX Modular Chassis Drive Packaged Drives Options Factory Supplied 900 kW 2000 kW A ROEA Modular Advanced Cooled Parallel Modular Air Cooled Parallel AC890PX Modular Advanced Cooled Parallel AC Drive Systems 500 2000 kW With the introduction of an innovative Parker engineered cooling system drive systems with increased power outputs can be created with an extremely compact footprint The award winning advanced cooling design draws from years of Parker experience in refrigeration technology combined with state of the art
6. per 100 m to a maximum of 2000 m Operating Humidity Maximum 90 relative humidity at 40 C non condensing Climatic Conditions Class 3k3 as defined by EN60721 Standards and Conformance Pollution degree II non conductive pollution except for temporary condensation Europe This product conforms with the Low Voltage Directive 2006 95 EC EMC Compatibility CE Marked to EN618000 3 EMC Directive Safety 0 SIL3 PLe as per EN13849 1 AC890PX Modular Chassis Drive Technical Characteristics Dimensions The AC890PX Modular Chassis Drive has been designed to mount in a standard 600 x 600 mm Rittal TS8 cubicle The mounting system is sufficiently flexible to allow the AC890PXM to be installed in other floorstanding enclosure with minimal modification If the product is to be mounted in a wider or deeper cubile then additional brackets may be required to form a rigid frame Refer to booklet HM501225U001 for detailed assembly and mounting instructions 79 5 170 0 170 0 R CC L lt gt 110 kW 1150 515 135 kg 132 kW 1150 500 515 135 kg 160 kW 1150 500 515 135 kg 200 kW 1150 500 51S 135 kg 250 kW 1150 500 S15 135 kg 280 kW 1150 500 JS 155 kg 315 kW 1150 500 JUS 155 kg Power Ratings are based on 400V nominal supply constant torque ratings All dimensions and weights are approximate O OSLL Drawing shows TS8006 backplate Connections Power connectors Safe Torque Off ST
7. 250 320 380 480 590 700 210 250 310 420 480 160 190 240 280 340 390 430 155 185 210 2995 340 365 410 140 Lie 210 270 325 405 Was 140 170 220 190 245 285 350 435 4795 520 180 230 EES 350 425 905 120 145 180 240 E 105 130 150 185 210 235 AC890PX Modular Chassis Drive Technical Characteristics Electrical Characteristics AC890PX Modular Chassis Drive Power Supply Requirements 3 300 460 VAC 3 500 575 VAC 3 600 690 VAC 10 10 10 45 65 Hz 2 kHz standard adjustable to 4 kHz de rating may apply 150 for 60 seconds 110 for 60 seconds 0 1000 Hz in V Hz mode 0 350 Hz in Closed loop vector mode 0 120 Hz in Sensorless vector mode gt 100 mA 0 94 Auxiliary Supply Requirements 24 VDC 30 W 8902 EQ Encoder Quadrature Incremental 8 W 8902 E1 Sin Cos Encoder 3 3 W 8902 M1 Mark Registration 1 W 5 V plus upto 3 W 24 V supply 8902 RE Resolver 3 2 W 8902 RR Resolver Repeater 4 4 W 8903 DN Devicenet 8903 CB CANopen 8903 CN ControlNet 1 3W 8903 SP Peer to peer 8903 PB Profibus 8903 PB Profibus 2 3 W 8903 NIM Modbus TCP 8903 IP Ethernet IP 1 6 W 8903 PB Profinet Environmental Characteristics Operating Temperature 0 to 40 C derate up to a maximum of 50 C 25 to 55 C 25 to 70 C Product Enclosure Rating IP20 NEMA 1 standard 1000 m ASL Derate output current by 1 5
8. Modular Chassis Drive Accessories and Options Input and Output Cards Auxiliary digital input 8903 M1 only 0 V to 5 V relative to X63 pin 5 15 V to 26 V relative to X63 pin 5 30 V relative to X63 pin 5 Low logic level lt 1 mA High logic level gt 3 mA lt 10 mA Typical input at 24 V 7 mA 30 V Input Safety Category SELV Terminal Type 6 way pluggable 3 5 mm terminal block 150 m screened cable is reccomended for all lengths but essential if over 30 m in order to comply with EMC regulations Auxiliary digital outputs 8903 M1 only Input Voltage VS B V to 24 V Maximum Input Voltage 30 V 100 mA per output Low logic level lt 3 V to 100 mA High logic level gt VS 4 V to 100 mA Indefinite withstand Max Output Frequency 250 kHz per output Terminal Type 8 way pluggable 3 5 mm terminal block 150 m screened cable is reccomended for all lengths but essential if over 30 m in order to comply with EMC regulations High Resolution Analogue Input 8903 Al and 8903 EP Encoder Card 250 kHz lt 10 mA per channel Description Two differential channels in quadrature The high resolution Analog Input Clock direction or clock only Option adds a sixth analogue input 30 V differential 0 30 V single ended to the AC890PX Modular Chassis 3 V 1 V differential drive This input can be used as the 8 V 1 V single ended other inputs within a configuration or Maximum output current
9. e Sensorless flux vector control A ultra high performance sensorless vector algorithm delivers a combination of both high torque and close speed regulation without the need for any speed measuing transducer e Closed loop flux vector control Full closed loop flux vector performance can be achieved by simply adding an encoder feedback technology box This provides 100 continuous full load standstill torque plus a highly dynamic speed loop more than sufficient for the most demanding of applications e Servo control Extremely fast control loops and process bus make the AC890PX Modular Chassis drive ideal for single Permanent magnet AC motor control e 4 Quadrant active front end power supply module The drive is used to feed energy back into the mains supply with sinusoidal currents and unity power factor with very low levels of harmonic distortion Suitable for use with AC induction and PMAC motors AC890PX Modular Chassis drive can control any of the following motor types offering total flexibility of motor selection allowing the most suitable motor to be selected for the application e AC Induction motors e PMAC servo motors e Torque Motors s e e e e e e ee e e e e e ee e e e e 6 66 e e 6 e eee 6 e e 6 666 ee 6 e e 666 e e ee 6 e ee 6 6 e e e e High speed PMAC servo motors Compatible with a wide range of feedback options Thanks to a range of optional feedback cards AC890PX Modular Chassis drive works with all types of
10. 0 mA per channel Description Two differential channels in quadrature The HTTL 8902 EQ speed feedback Clock direction or clock only option allows incremental encoders 30 V differential 0 30 V single ended to be connected directly to the drive 30 V maximum to provide highly accurate speed 3 V 1 V differential feedback measurement Supplies 8 V 1 V single ended variable voltage isolated encoder Encoder Power Supply Maximum load 200 mA or 2 W power supply Resolver Feedback Card 8902 RE L i E oa Maximum Speed Up to 50000 min with 2 pole resolver Carrier Output Signal 7 Vrms 8 kHz s Maximum Carrier Supply 70 mArms os 12 Vpeak p Description lt 5 T The 8902 RE resolver speed Resolution Equivalent to 16 bits in one revolution of resolver feedback option allows the resolver Inputs Differential inputs Zin 2 KQ to be connected directly to the drive Maximum Input Voltage 12 Vpeak to provide highly accurate speed feedback measurement Contains a Carrier output signal to power the resolver 21 AC890PX Modular Chassis Drive Accessories and Options Feedback Cards SinCos EnDat2 1 Feedback Card 8902 E1 8902 EI 00 00 Optional SinCos encoder card Maximum Pulse Rate 250 kHz Receiver Impedance 1200 Input Format two differential 1 V signals in quadrature Maximum load 250 mA Adjustable Voltage 5 V 10 V Description The SinCos speed feedba
11. 5 keys for on screen menus TS8008 7 keys for on screen menus TS8010 8 keys for on screen menus TS8015 9 keys for on screen menus Memory CompactFlash slot Programming USB 1 1 connector type B RS232 via RJ12 Communication Ports Communication RS232 via RJ12 RS485 via RJ45 Ethernet 10 100 Base T connector RJ45 30 AC890PX Modular Chassis Drive Related Products Features Multilingual Interface Pre Engineered Projects Programming and Displayin e Library with over 4000 symbols Italian German English e Support for BMP JPG WMF Spanish French Dutch graphic files Unicode Support for e Database functionality Japanese Chinese traditional Chinese simplified Thai Korean Others available Graphical Trend Alarm Logs Machine Drawings Dimensions 189 2 148 6 153 4 112 8 0 89 224 3 esas 58 4 188 5 144 1 36 262 207 8 56 226 3 172 1 74 325 8 241 3 56 293 3 2 10 1 25i 406 4 330 2 78 6 370 6 294 4 5 17 J CANopen fieldbus option card master DeviceNet option card Siot for CompactFlash Profibus option card LINK fieldbus option card FireWire fieldbus option card Power Supply A5485 R5232 Ethernet Mini USB AS23727 Communrcation 24de Comnunicabon pey L Presgreurwringy _ Module 31 AC890PX Modular Chassis Drive Related Products TMW Series Torque Motors 1200 22 100 Nm Description Parker Torque Motors are complete and ready to use direct drive systems specifically desi
12. C890PX Series STO card CS module AC890PXS only CD module CP module 400 kW only Set of control cables AC890PX Modular Chassis Drive Technical Characteristics Technical Characteristics Power Ratings Nominal 400 VAC modules 565 VDC 890PX 43215 890PX 43260 890PX 43300 890PX 43420 890PX 43480 890PX 43520 890PX 43580 Nominal 460 VAC modules 650 VDC 890PX 43215 890PX 43260 890PX 43300 890PX 43420 890PX 43480 890PX 43580 Nominal 575 VAC modules 810 VDC 890PX 63160 890PX 63210 890PX 63260 890PX 63310 890PX 63410 Nominal 690 VAC modules 975 VDC 890PX 73130 890PX 73160 890PX 73190 890PX 73230 890PX 73280 890PX 73320 890PX 73340 110 147 S277 160 214 200 268 250 335 280 375 315 422 112 150 149 200 187 250 224 300 298 400 373 500 112 150 149 200 224 300 112 150 298 400 110 147 132 177 160 214 200 268 250 335 280 375 315 422 See Ordering Information for full order codes and description 132 177 160 214 200 268 250 335 315 422 355 476 400 536 149 200 187 250 224 300 298 400 298 400 448 600 149 200 187 250 224 300 298 400 298 400 132 177 160 214 200 268 250 335 315 422 355 476 400 536 215 260 300 420 480 580 200 250 300 380 460 580 160 210 260 310 410 130 160 190 230 280 320 340 260 340 390 480 600 660 720
13. DINOUT2 DOUT4A DOUT4B DOUTSA DOUTSB DOUT6A DOUT6B THERMB THERMA tag Description Digital Input 1 Jog Digital Input 2 Run Digital Input 3 Stop Digital Input 4 Reverse Digital Input 5 Unassigned Digital Input 6 Unassigned Digital Input 7 Unassigned Digital In Out Running Dgitial In Out Zero Speed Relay output 4 Relay output 4 Relay output 5 Relay output 5 Relay output 6 Relay output 6 Motor thermistor input B Motor thermistor input A OV AIN1 AIN2 AIN3 Remote Setpoint AIN4 Speed Trim AOUT1 Speed Feedback AOUT2 Torque Feedback 10 V 10V STO Status STO Status 24 VDC Daisy chain to next drive 0 VDC DOUT3A DOUT3B 24V OV DIN1 Jog DIN2 Run DIN3 Stop DIN4 Reverse DIN5 Unassigned _ DING Unassigned DIN7 Unassigned DIN8 DOUT1 Running DIN9 DOUT2 Zero Speed AC890PX Modular Chassis Drive Technical Characteristics Standard Power Configurations r Pee ke He bee He d EMC Filter L eee i i ee s d Output Motor Chokes Where cable runs exceed 100 m the use of motor chokes is advised to prevent nuisance tripping of the drive due to capacitive currents AC Line Chokes Line chokes providing 3 line impedance are mandatory for the AC890PX Series drives and have several benefits including e Protecting the drive from voltage drops e Eliminating nuisance trips
14. KW 33 Square Frame Asynchronous Vector Motors 0 75 kW 314 KW 33 Parker Hannifin the global leader in motion and control technologies A world class player on a local stage Global Product Design Parker Hannifin has more than 40 years experience in the design and manufacturing of drives controls motors and mechanical products With dedicated global product development teams Parker draws on industry leading technological leadership and experience from engineering teams in Europe North America and Asia Local Application Expertise Parker has local engineering resources committed to adapting and applying our current products and technologies to best fit our customers needs Offenburg Germany Littlehampton UK Manufacturing to Meet Our Customers Needs Parker is committed to meeting the increasing service demands that our customers require to succeed in the global industrial market Parker s manufacturing teams seek continuous improvement through the implementation of lean manufacturing methods throughout the process We measure ourselves on meeting our customers expectations of quality and delivery not just our own In order to meet these expectations Parker operates and continues to invest in our manufacturing facilities in Europe North America and Asia Local Manufacturing and Support in Europe Parker provides sales assistance and local technical support through a networ
15. O The AC890 series features Safe Torque Off functionality as standard offering users protection against unexpected motor start up in accordance with EN 13849 1 PLe or SIL 3 The STO functionality helps protect personnel and machinery by preventing the drive from restarting automatically It disables the drive pulses and disconnects the power supply to the motor so that the drive cannot generate any potentially hazardous movement The state is monitored internally within the drive The example wiring diagram shows the minimum connections required to implement STO with the AC890PXM series AC drives AC890PX Modular Chassis Drive Technical Characteristics DC DC Link Bus Ve DC DC Link Bus Ve L1 L1 AC Input Supply GND Earth J L2 L2 AC Input Supply DBR Dynamic Brake Resistor L3 L3 Ac input Supply M1 U Motor Output U M2 V Motor Output V M3 W Motor Output W X11 01 X11 02 X11 03 X11 04 X11 05 X11 06 X11 07 Users must conduct a risk assessment to identify the appropriate STO wiring scheme and ensure that all safety requirements are met STOA To disable STO connect to X14 03 STO OV To disable STO do not connect STO B To disable STO connect to X14 03 STO OV To disable STO connect to X14 04 STATUS To disable STO do not connect STATUS To disable STO do not connect STO OV To disable STO connect to X14 04 24 VDC DRIVE STO START REQUEST D L O 11 01 X11 03 X11 06 14 03 AC890 AC890P
16. X Series STO X14 04 It is the user s responsibility to ensure the safe and correct use of the STO function of the AC890PX Series User s should read and fully understand chapter 6 Safe Torque Off of the product user manual Manual No HA501299_ 01 AC890PX Modular Chassis Drive Technical Characteristics Non power connectors Term X10 X12 01 X12 02 X12 03 X12 04 X12 05 X12 06 X12 07 X12 08 X12 09 X13 01 X13 02 X13 03 X13 04 X14 01 X14 02 X14 03 X14 04 Label OV AIN1 AIN2 AIN3 AIN4 AOUT1 AOUT2 10 V 10 V 24 VDC 24 VDC 0 VDC OV DOUT3A DOUT3B 24 VDC OV Description USB programming port 0 V Reference Supply Analogue Input 1 analogue Input 2 Analogue Input 3 Remote setpoint Analogue Input 4 Speed Trim AOUT1 Speed Feedback AOUT2 Torque Feedback 10 V Reference Supply 10 V Reference Supply 24 VDC User Supplied 24 VDC Daisy chain out to next drive 0 VDC Daisy chain out to next drive 0 V User Supplied Drive healthy relay output Drive healthy relay output 24 V DC Common supply U V Reference Speed Term X15 01 X15 02 X15 06 X15 04 X15 05 X15 06 X15 07 X15 08 X15 09 X16 01 X16 02 X16 03 X16 04 X16 05 X16 06 X16 08 X16 09 Potentiometer To Control Bracket Encoder ro 24 V Auxiliary Supply Shield BAIN optional Drive Healthy DR ZS Label DIN1 DIN2 DINS DIN4 DIN5 DING DIN7 DINOUT1
17. aerospace climate control filtration fluid amp gas handling hydraulics pneumatics process control sealing amp shielding AC890PX Modular Chassis Drive High Power AC Drive 110 kW 2000 kW Barker ENGINEERING YOUR SUCCESS A WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE e This document and other information from Parker Hannifin Corporation its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise The user through its own analysis and testing is solely responsible for making the final selection of the system and components and assuring that all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the application follow applicable industry standards and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably
18. ck option 8902 E1 allows a1 V SinCos encoder to be connected directly to the drive to provide highly accurate speed feedback measurement Decodes Heidenhain EnDat2 1 absolute position encoders and supplies 5 V or 10 V for the encoder SinCos registration position 8902 M1 and 8903 M1 Maximum Pulse Rate 250 kHz Receiver Impedance 1200 Description Input Format 2 differential 1 V signals in quadrature e The 8903 M1 00 and 8902 MA 00 Encoder Supply 250 mA maximum load feedback cards allow operation Supply Voltage B V 10 V adjustable without external registration Terminal Type Sub D15 connector position thanks to the connection Maximum Cable Length 150 m screened cable of the encoder to the drive They provide highly accurate speed feedback measurement and regstration Nevertheless registration applications are best achieved when both cards are used e Interpolates each encoder line with 11 bit accuracy giving 4 million counts rev on a 2048 line encoder e Supplies 5 V or 10 V to the encoder e Decodes Heidenhain EnDat2 1 J absolute position encoders e Isolated digital inputs that can be used either for general purpose inputs or for inputs from registration mark sensor 8903 M1 only lt lt 3 non isolated digital outputs that can be either for general purpose outputs or for synthesizing an encoder output 8903 M1 only L NO 2 AC890PX
19. configuration and monitoring e System identification tool Parameter adjustment and project creation Product Codes 8906 DSELITE 00 8906 DSEDEV 00 8906 DSERUN 00 8906 DSEDE 906 DSERUNUPG 00 real time data acquisition oscilloscope System identification tool NO 6 Order Code AC890PX Modular Chassis Drive 09 4 5j 6ej 7 8 o io 11 12 13 14 AC890PX Modular Chassis Drive Order Code 890PX S C A A High Power Modular AC Drive Series Standalone Drive SD Common DC Bus Drive CD Air Cooled 400 460 V Nominal Supply 575 V Nominal Supply 690 V Nominal Supply 400 460 V Nominal Supply 3215 3260 3300 3420 3480 3520 3580 110 132 kW 150 200 HP 132 160 kW 200 250 HP 160 200 kW 250 300 HP 200 250 kW 300 400 HP 250 280 kW 400 500 HP 280 315 kW 375 476 HP 315 400 kW 500 600 HP 575 V Nominal Supply 3160 3210 3260 3310 3410 112 149 kW 150 200 HP 149 187 kW 200 250 HP 187 224 kW 250 300 HP 224 298 kW 300 400 HP 298 373 kW 400 500 HP 690 V Nominal Supply 3130 3160 3190 3230 3280 3320 3340 M 0 B 110 kKW 132 kW 150 200HP 132 kW 160 kW 200 250 HP 160 kW 200 kW 250 300 HP 200 kW 250 kW 300 400 HP 250 kW 280 kW 400 500 HP 280 kW 315 kW 375 476 HP 315 kW 400 kW 500 600 HP Modular Chassis Drive Brake not available for CD inverter Brake fitted as standard to SD inverter
20. d Cooled AC Systems Drive 500 kW 2 MW Higher power ratings of up to 2 MW can be achieved using Parker s innovative advanced cooled PowerPak modules These larger drives use the same modular construction as the rest of the AC890PX Modular Chassis drive range but are supplied with Parker s 2 phase advanced cooling system which uses a non conductive liquid refrigerant This enables power density to be increased significantly resulting in a significantly smaller footprint than can be achieve by air cooling alone AC890PX Modular Chassis Drive Overview Product Description The AC890PX Modular Chassis is a modular high power AC drive platform designed for industrial applications with power requirements ranging from 110 KW up to 2000 kW Available in kit form for integration into a standard control enclosure or as a packaged standalone air cooled or 2 phase liquid refrigerent cooled drive AC890PX Modular Chassis drives can be configured for use in a wide range of applications and industries Compact Modular Design The plug in modular nature of the AC890PX Modular Chassis makes it easy to configure the drive to suit a number of alternative input power configurations including 12 18 pulse and Active Front End AFE The PowerPak phase modules common supply modules capacitor and control module can be arranged to suit the particular requirements of the application PowerPak Phase Module Low maintenance ensures maxi
21. drive design to produce a truly high performance AC drive range The hermetically sealed system has no compressor requires no routine maintenance and uses a non conductive non corrosive coolant AC890PX Modular Chassis Drive Related Products Related Products HMI Touchscreens TS8000 Series TS8000 is a high performance HMI touchscreen range with powerful features that would normally only be found in PC based displays The TS8000 is able to communicate with many different pieces of hardware through its 10 100Base T Ethernet port Furthermore a USB programming port allows programs to be downloaded or access to trending and data logging while data can be collected and stored on a standard CompactFlash card freeing up internal memory Multi lingual interface e Built in symbol library of HMI specifications common objects Model Screen Colour Number of Pixels Built in web server TS8003 32 FSTN 2 128 x 64 e CompactFlash support e Integrated automatic multiple TS8006 5 TET 256 QVGA 320 x 240 protocol conversion e Free programming software TS8008 7 7 DSTN 256 VGA 640 x 480 TS8010 10 4 TFT TS8015 TS ET 32 000 XGA 1024 x 768 Technical specifications Power Supply 24 VDC 20 Operating Temperature 0 50 C Relative Humidity 80 non condensing Altitude 2000 m Enclosure IP66 Nema 4 Keypads TS8003 8 user assignable keys 5 navigation keys 12 numeric keys 7 dedicated keys TS8006
22. e Reducing harmonic distortion of the supply e Increasing the life of the drive EMC Filter Optional These EMC filters arer a cost effective and easily implemented solution for the reduction of Radio Frequency Interference RFI in order to meet the requirements of EN61800 3 EMC directive Semi Conductor Fuses Short circuit protection semiconductor fuses should be installed in the 3 phase supply to the CS input module to protect the drive s input bridge Circuit breakers of HRC fuses will not sufficiently protect the input bridge 17 AC890PX Modular Chassis Drive Technical Characteristics Versatile Power Configurations The AC890PX Series can be configured to operate in a number of different power configuration modes to suit the exact requirments of your application The modularity of the AC890PX Series enables different combinations of PowerPak modules to be easily selected and installed to achieve these schemes without involving significant amounts of pre engineering work Standard Inverter SD Standard inverter configuration for control of single motor applications in either open or closed loop mode DC Fed Inverter CD DC fed inverter for either single or multi drive configurations where a suitable DC input supply is available DC Input Common DC Bus System Common DC bus system using a standard SD inverter with a high power input stage to supply multiple CD common bus drives e Power range
23. eforms are almost sinusoidal which minimizes network harmonics Nominal 400 VAC LA482468U220 LA482471U220 C0O468326U220 CO0468325U220 LA482468U315 LA482471U315 CO0468326U315 CO0468325U315 LA482468U355 LA482471U355 CO0468326U355 CO0468325U355 Nominal 500 VAC LA482469U220 LA482472U220 CO0468326U220 CO0468325U220 LA482469U315 LA482472U315 CO0468326U315 CO0468325U315 LA482469U355 LA482472U355 CO0468326U355 CO0468325U355 CD CD AC Input additional drives stages LCL Filter Typical AFE drive configuration AC890PX Modular Chassis Drive Accessories and Options Drive System Explorer DSE Software Description DSE890 is the programming monitoring and diagnostic software platform for AC890 and AC890Px series variable speed drives DSE890 Programming Software Communication between the drive and PC is via a mini USB port located on the front of the drive Thanks to the on line help users can achieve the optimum drive configuration without the need to navigate through complicated parameter menus Advanced programming is carried out through a set of pre engineered templates in order to create the required configuration It is possible to monitor every parameter of the drive either as a digital value or as a function in the chart recorder during normal operation Creates projects quickly and easily e Graphical tool based on a block diagram approach e Integrated digital oscilloscope e On line
24. egration into power drive systems Drive shown part assembled Technical Characteristics Overview The AC fed SD version of the AC890PX Modular Chassis drive is available with three AC input power supply options to suit individual requirements 380 480 VAC 500 575 VAC 600 690 VAC kW ratings 400 VAC 50 Hz HP ratings 460 VAC 60 Hz HP ratings kW ratings 575 VAC 60 Hz 690Vac 50 Hz 110 315 kW 110 315 kW 110 315 kW 215 580 A 160 410 A 130 340 A 150 500 HP 200 400 HP 200 400 HP 200 580 A 160 410 A 130 340 A 150 overload for 60 s 400 kW 132 400 kW 132 400 kW f00A 170 440A 160 430 A 600 HP 200 500 HP 200 500 HP f00 A 240 500A 160 430 A 110 overload for 60 s AC890PX Modular Chassis Drive Overview Range Overview The AC890PX Modular Chassis Drive is a high performance high power modular drive designed to control 3 phase induction or permanent magnet AC motors or to be used as an active front end with power ratings ranging from 110 kW 2000 kW It can be supplied either in modular kit form or as a packaged drive system AC890PX Modular Chassis High Power AC Drive 110 400 kW The AC890PX Modular Chassis drive has been designed to be sold in kit form for assembly by a system integrator or panel builder The product is engineered for easy assembly into a standard industrial enclosure with all necessary fixing brackets supplied as
25. foreseeable uses of the components or systems High Power AC Drive AC890PX Modular Chassis Drive VOC EA E E E use dnsadass EE EE 5 Range UVerVieWw eee e 6 Product Description sss eee eee 7 Features and Bs NOTIN ET 8 PNG 5519 2 Control 016 oe eee ne ee ee ee eee E eee eae 9 HT 10 Application S oct enet Setoccasecetccesansnensoesansueasszmoraiqsautees E aeaa 10 Component List VET TT 11 Technical CharacterisStics 2 ccssecssecseeceeeeeeseeeeeeeeeeeees 12 POWT IHH E 12 Electrical Characteristics eee 13 Environmental Characteristics eee 13 Standards and Conformance sss eee eee 13 EI THT 14 BTT ONS eee ena ae eer eat en a nee en ee ee ee ene eee eee 15 Standard Power CONMGUlallONS weccinccceptssccecccucasbidonstncdemtededaodetesingodetedadeiderede 17 Accessories and Options csceceseneesenceeenenseeeneesenensenens 20 COMMUNICATION Interfaces eee eee 20 FO SCG a OS gees cease gece E e E A E AEE E 21 niput and Output e essa vavatuetinaetaccoue muetiyaretaveemieueeleneeitiumebetaradseniives 23 Ls anrr POU E E E T E E E E E E TT 24 Drive System Explorer DSE Sofware 26 Order COG i arenicnenacannwenacesavesansensecsuecepuesiiaenbantoieesnnesnnesnienn 27 Packaged Drives Options Factory Supplied 28 RELALCO T Nns l aT 30 Sla o 30 TMW Series Torque Motors 1200 22 100 Nm sese 32 MGV High Speed Low Inertia Servo Motors sss 32 Round Frame Asynchronous Vector Motors 0 18 kW 315
26. gned for use with AC890 and AC890PX Modular Chassis drives to fully and effectively respond to the specific needs of the Plastics and Rubber industries Developed in collaboration with machine builders and end users a number of innovative dedicated features have been integrated into the motors such as a generously sized integrated thrust bearing to support back pressure from the screw as well as specific mechanisms allowing quick and easy removal of the screw from the motor Delivering torques up to 22100 Nm at speeds ranging from 50 to 500 min Parker Torque Motors represent the perfect alternative to gearbox based systems for extruders applications of power up to 400 kW e High power compact design e Water or natural cooling e Overtemperature protection built in e Wide range of feedback devices e Integrated thrust bearing e Customizable shaft ends e P54 protection e IMB3 mounting MGV High Speed Low Inertia Servo Motors Description MGV Series servo motors are innovative direct drive solutions specially designed for applications that require high speeds and low inertias MGV motors can be found in many automotive or aeronautical component test rigs starters pumps alternators gearboxes Highly responsive with exceptional dynamic performance MGV motors are ideally suited to the needs of simulation testing speed in urban cycle or motor racing speed cycling of an internal combustion engine etc e High maximum
27. interface Supported Protocols PROFIBUS DP Demand data and Data exchange Communication Speed Up to 12 Mbits s selected by the master Station Address DIP switch or software setting of station address Suitable for firmware Version 1 4 Communication Speed Up to 400 MBaud Peer to peer communication between drives via IEEE 1394 standard Suitable for firmware Version 3 2 20 AC890PX Modular Chassis Drive Accessories and Options Communication Interfaces Supported Protocols PROFINET I O Real Time RT Protocol S Communication Speed 100 Mbits s x Station Address Software setting of station address via DSE Suitable for firmware Version 3 3 8903 SP 00 CAN peer to peer communication interface Supported Protocols Peer to peer data exchange with other drives Communication Speed Up to 1 Mbits s selectable by DIP switch Station Address Selected by DIP switch setting Suitable for firmware Version 3 3 Supported Protocols CANopen over EtherCAT CoE DS301 compliant Communication Speed 100 Mbits s Suitable for firmware Version 3 7 8903 RS 00 RS485 Modbus communication interface Supported Protocols Modbus RTU only Communication Speed 1200 to 115200 bits s Station Address Selectable via software Suitable for firmware Version 3 7 Feedback Cards Incremental Quadrature Encoder Card 8902 EQ 250 kHz differential 200 kHz single ended lt 1
28. k of dedicated sales teams and authorized technical distributors throughout Europe For contact information please refer to the Sales Offices on the back cover of this document or visit www parker com Manufacturing O Parker Sales Offices Distributors Worldwide Manufacturing Locations Europe Littlehampton United Kingdom Dijon France Offenburg Germany Milan Italy Asia Shanghai China Chennai India North America Rohnert Park California Irwin Pennsylvania Wadsworth Ohio Charlotte North Carolina New Ulm Minnesota Dijon France 192 300030N1 688358 High Power AC Drive AC890PX Modular Chassis Drive www parker com ssd ac890pxm AC890PX Modular Chassis Drive Overview Description AC890PX Modular Chassis drive is supplied in a kit format for assembly into a standard Rittal TS range industrial enclosure This enables system integrators and panel builders to add any number of drive sections into their standard electrical control systems thereby reducing overall enclosure size and complexity The AC890PX Modular Chassis kit is supplied complete with all of the necessary individual components and fixings required to complete the assembly of the drive It can easily be assembled by a technician with minimal drives technical knowledge Features e AC Fed SD or DC Fed CD modular design configuration e Power range 110 400 kW e Sold in kit format for self assembly e Easy int
29. lain language and engineering units PLC like function blocks for advanced applications e Multilingual e Quick setup menu e Auto tuning e Diagnostic messages e Drive configuration Applications AC890PX Modular Chassis drives are suited to many different motor control and power conversion applications where power density and compactness are key design considerations e Fan and pump control e Automotive test stands e Extruders e Decanter and batch centrifuges e Hoists and cranes e Winder un winder stands e Ski lifts and cable cars e Wind turbine grid tie Drive System Explorer DSE DSE software allows users to program configure monitor and diagnose AC890PXM drives with the use of a PC An easy to use interface guides the user through every step of project creation and implementation TUR EERTE wa aad 7 ye TRS e here BLAR E i TEESE R EEE mamm me g lt e Offshore and marine e Solar energy capture e Ocean wave energy grid tie AC890PX Modular Chassis Drive Overview Component List Overview The following is an overview of the parts supplied as part of a AC890PX Modular Chassis kit The actual contents will vary dependant upon the configuration and rating of the product ordered Backplate Busbar Assembly L pes Pair of mounting rails Set of TS8 mounting brackets and assembly screws Vent hood AC890 series control module A
30. merica CA Canada Milton Ontario Tel 1 905 693 3000 US USA Cleveland Tel 1 216 896 3000 Asia Pacific AU Australia Castle Hill Tel 61 0 2 9634 7777 CN China Shanghai Tel 86 21 2899 5000 HK Hong Kong Tel 852 2428 8008 IN India Mumbai Tel 91 22 6513 7081 85 JP Japan Tokyo Tel 81 0 3 6408 3901 KR South Korea Seoul Tel 82 2 559 0400 MY Malaysia Shah Alam Tel 60 3 7849 0800 NZ New Zealand Mt Wellington Tel 64 9 574 1744 SG Singapore Tel 65 6887 6300 TH Thailand Bangkok Tel 662 186 7000 99 TW Taiwan Taipei Tel 886 2 2298 8987 South America AR Argentina Buenos Aires Tel 54 3327 44 4129 BR Brazil Sao Jose dos Campos Tel 55 800 727 5374 CL Chile Santiago Tel 56 2 623 1216 MX Mexico Apodaca Tel 52 81 8156 6000 192 300030N1 August 2012 from AT BE CH CZ DE DK EE ES FI FR IE IL IS IT LU MT NL NO PL PT RU SE SK UK ZA US Product Information Centre Toll free number 1 800 27 27 537 www parker com Your local authorized Parker distributor
31. mp adapters e Rotary actuators e High temperature metal seals s Quick disconnects e Quick disconnects e Tie rod cylinders e Metal amp plastic retained e Vacuum generators cups amp sensors composite seals e Thermal management 35 Parker Worldwide Europe Middle East Africa AE United Arab Emirates Dubai Tel 971 4 8127100 parker me parker com AT Austria Wiener Neustadt Tel 43 0 2622 23501 0 parker austria parker com AT Eastern Europe Wiener Neustadt Tel 43 0 2622 23501 900 parker easteurope parker com AZ Azerbaijan Baku Tel 994 50 2233 458 parker azerbaijan parker com BE LU Belgium Nivelles Tel 32 0 67 280 900 parker belgium parker com BY Belarus Minsk Tel 375 17 209 9399 parker belarus parker com CH Switzerland Etoy Tel 41 0 21 821 87 00 parker switzerland parker com CZ Czech Republic Klecany Tel 420 284 083 111 parker czechrepublic parker com DE Germany Kaarst Tel 49 0 2131 4016 0 parker germany parker com DK Denmark Ballerup Tel 45 43 56 04 00 parker denmark parker com ES Spain Madrid Tel 34 902 330 001 parker spain parker com Fl Finland Vantaa Tel 358 0 20 753 2500 parker finland parker com FR France Contamine s Arve Tel 33 0 4 50 25 80 25 parker france parker com GR Greece Athens Tel 30 210 933 6450 parker greece parker com HU Hungary Budapest Tel 36 23 885 470 parker hungary parker com IE
32. mp beverage many angles to find new e Business amp general aviation e Air conditioning e Factory automation e Industrial machinery e Commercial transports e Food beverage amp dairy e Food amp beverage e ife sciences ways to create value What e and based weapons systems e Life sciences amp medical e ife science amp medical e Marine ever the motion and control e Military aircraft e Precision cooling e Machine tools e Mobile equipment technology need Parker has e Missiles amp launch vehicles e Processing e Packaging machinery s Oil amp gas e Regional transports e Transportation e Paper machinery e Power generation the experience breadth of e Unmanned aerial vehicles e Plastics machinery amp converting e Process product and global reach Key Products e Primary metals e Transportation to consistently deliver No Key Products e C02 controls 6 semiconductor amp electronics e Flight control systems e Electronic controllers e Textile Key Products company knows more about amp components e Filter driers e Wire amp cable e Analytical gas generators motion and control technol e Fluid conveyance systems e Hand shut off valves e Compressed air amp gas filters e Fluid metering delivery e Hose amp fittings Key Products e Condition monitoring ogy Man Ranker Tortura amp atomization devices e Pressure regulating valves e AC DC drives amp systems e Engine air fuel amp oil filtration info call 00800 27 27 5374 e Fuel systems amp com
33. mum machine up time and CP Err r N productivity Module Thanks to a plug in design the power modules of the AC890PX Modular CARR Chassis drive has been designed to be replaceable in minutes by any technician even a non specialist These lightweight ship anywhere modules help to reduce machine or process downtime and lost productivity in the event of a fault occurring Module AC890PX Modular Chassis drives can be configured with different PowerPak module combinations dependant upon the application CD Module CP Module l The capacitor module is only fitted to 400 kW drives and provides extra Capacitance for the DC bus CD Module l CD i These output modules each provide a single phase of the complete drive Module 4 and can be interchanged with each other CS Module A 3 phase input rectifier containing a half controlled diode thyristor bridge cs d This module supplies DC to the three CD modules and also includes an Module integral dynamic brake switch AC890PX Modular Chassis Drive Overview Features and Benefits AC890PX Modular Chassis drive can be configured for five modes of operation allowing the appropriate level of control to be selected for the motor and application e QOpen loop V F speed control This is the simplest form of control available and is ideal for motor speed control where an AC induction motor is controlled by varying the voltage and frequency supplied to the motor
34. n technology e Mobile e Oil amp gas e Transportation amp automotive Key Products e if sciences o Oil amp gas e Power generation amp energy e Analytical sample conditioning e Military e Transportation e Truck hydraulics Key Products products amp systems e Semiconductor e Welding e Air preparation e Fluoropolymer chemical delivery e Telecommunications Key Products e Compact cylinders fittings valves amp pumps e Transportation Key Products e Diagnostic equipment e Field bus valve systems e High purity gas delivery fittings e Brass fittings amp valves e Hydraulic cylinders e Grippers valves amp regulators Key Products e Diagnostic equipment amp accumulators e Guided cylinders e Instrumentation fittings valves e Dynamic seals e Fluid conveyance systems e Hydraulic motors amp pumps e Manifolds amp regulators e Flastomeric 0 rings e Industrial hose e Hydraulic systems e Miniature fluidics e Medium pressure fittings amp valves e EMI shielding e PTFE amp PFA hose tubing amp e Hydraulic valves amp controls e Pneumatic accessories e Process control manifolds e Extruded amp precision cut plastic fittings e Power take offs e Pneumatic actuators amp grippers fabricated elastomeric seals e Rubber amp thermoplastic hose e Rubber amp thermoplastic hose e Pneumatic valves and controls e Homogeneous amp inserted amp couplings amp couplings e Rodless cylinders elastomeric shapes e Tube fittings amp adapters e ube fittings a
35. ology to best suit the needs of their application Features E Open standards for protection Support for popular industrial Ultra fast control loops Z of investment fieldbus networks e Torque loop 62 5 us J The AC890PX Modular Chassis E aaro CANopen e Speed loop 62 5 us drive has been specifically designed mere DeviceNet P _ pran E po 4 to integrate seamlessly into your E l ang S CAOR QOP DEn He automation network with the adition a gt aero 5 of a communications interface Open FireWire IEEE 1394 Range of feedback options roces Kor e Incremental encoder mee HS ioe ne a e EnDat 2 2 option 02 e Real time synchronization between drives SinCos encoder e Resolver Two performance levels to suit all applications Advanced Performance High Performance Motion control with position control All advanced features plus Motion control function blocks incremental move Library of pre engineered application specific LINK VM absolute move move home function blocks such as Section Control line drive master ramp winder blocks Shaftless printing cut to length adanced winding and speed and current winder PID process sequencer advanced traversing control AC890PX Modular Chassis Drive Overview Tools Programming Operator Controls The AC890PX Modular Chassis drive operator keypad provides access to all pf the drive s functions in a logical and intuitive manner The backlit display presents all functions in p
36. part of the kit The AC890PX Modular Chassis drive offers systems builders the flexibility to add all ancillary components in order to tailor the product to meet their customers needs Packaged Drive Options Factory Supplied 100 400 1 NW 2MW l AC890PX Modular FASTPACK simple packaged drive system 110 400 kW The AC890PX Modular FASTPACK provides users with a ready to install standalone drive in an industrial enclosure complete with all additional control equipment FASTPACK delivers an integrated packaged solution for single motor applications on short lead times A range of standard pre engineered control and communications options can be specified to complete the package and provide the neccessary control and feedback whatever the application 1 MW 400 900 kW 100 400 2 MW AC890PX Modular Air Cooled Parallel AC Systems Drive 400 900 kW Larger power paralleled drive solutions based on the AC890PX Modular Chassis drive can be supplied as a fully engineered solution direct from the factory This allows up to three AC890PX Modular Chassis drives to be paralleled together to achieve control of motors with powers up to 900 kW The air cooled solution provides a cost effective solution as the modular design of the product allows only the required power stages to be supplied to create a parallel solution 100 400 1 NW 2MW E 110 400 kW 100 400 1 NW 2MW a AC890PX Modular Advance
37. ponents e Refrigerant distributors e Electric actuators amp systems e Hydraulic systems amp components e Safety relief valves e Controllers e Hydraulic lubrication amp e Inert nitrogen generating systems e Solenoid valves e Gantry robots coolant filters e Pneumatic systems amp components e Thermostatic expansion valves e Gearheads e Process chemical water e Wheels amp brakes e Human machine interfaces amp microfiltration filters e Industrial PCs e Nitrogen hydrogen amp zero e Inverters air generators e inear motors slides and stages e Precision stages e Stepper motors e Servo motors drives amp controls e Structural extrusions FLUID amp GAS HANDLING HYDRAULICS PNEUMATICS PROCESS CONTROL SEALING amp SHIELDING Key Markets Key Markets Key Markets Key Markets Key Markets e Aerospace e Aerospace e Aerospace e Chemical amp refining e Aerospace e Agriculture e Aerial lift e Conveyor amp material handling e Food beverage amp dairy e Chemical processing s Bulk chemical handling e Agriculture e Factory automation e Medical amp dental e Consumer e Construction machinery e Construction machinery e Food amp beverage e Microelectronics e Fnergy oll amp gas e Food amp beverage e Forestry e ife science amp medical e Oll amp gas e Fluid power e Fuel amp gas delivery e Industrial machinery e Machine tools e Power generation e General industrial e Industrial machinery s Mining e Packaging machinery e Informatio
38. popular feedback systems providing greater flexibility during the design stage of a project e Incremental encoder e Resolver e SinCos Endat 2 1 encoder e Absolute encoder EnDat2 2 option 02 AC induction motors PMAC brushless motors s e e e e e ego ee 6 6 e Torque motors High speed PMAC motors AC890PX Modular Chassis Drive Overview AC890PX Control Module At the heart of the AC890PX Modular Chassis drive is a highly advanced control module that manages all of the drives functions Taking advantage of leading edge control algorithms running on a fast 150 MHz microprocessor the drive can achieve very high bandwidth control loops This allows you to use the drive for the most demanding of industrial applications Benefits Integrated safety functionality The integrated Safe Torque Off STO functionality offers protection against unexpected motor start up in accordance to EN 13849 1 PLe SIL 3 as standard Minimal delay between fieldbus setpoints and the control loops Designed to integrate in existing automation systems the AC890PX Modular Chassis drive features high performance ports linked directly to the fast control loops of the drive Minimum delay exists between your digital setpoint sent through a fieldbus and the control loops Flexible feedback options The AC890PX Modular Chassis drive offers system designers complete l flexibility in their choice of feedback R techn
39. rrent Order Code 250A ___ C0471702U250 S200A00 CUATHITU2U320 400A C0471702U400 SOA CC0471702U500 GOA __s C0471702U600 TOA 60471702750 Auxiliary Transformers 1 kVA 30 VAC control transformer for auxiliary power supply requirements 400 480VAC C0501514 500 690 VAC 0 C0501515 NO 4 AC890PX Modular Chassis Drive Accessories and Options EMC Filter A range of custom designed optional EMC Electromagnetic Compatibility filters are available for use with Parker SSD Drives product range They are used to help achieve conformance with the EMC directive BS EN 61800 3 2004 Adjustable speed electrical power drive systems Part 3 Upto 132kW C0467843U340 Upto3t5kW 2 off C0467843U340 AFE 4 Quadrant In many applications the overall power consumed by the system is less than the sum of power of the installed motors as some motors will be driven electrically while others are coasting being driven by the momentum of the machine For such applications it is beneficial to connect the drives of all sections of the machine to a common DC bus the energy generating sections are then fed into the energy consuming sections which reduces the overall energy consumption of the system I aS gt Thanks to the 4 quadrant 4Q functionality of the AC890PX Series excess energy in the system is returned to the network and not dissipated in the form of heat through braking resistors The current wav
40. speeds avoid the need for mechanical gearing e Low inertia allowing very fast acceleration deceleration e Constant power operation above nominal speed removes the requirement to oversize the drive e Water cooling ensures compact size and low noise operation e High dynamic capabilities allow the operating conditions of the tested product to be accurately reproduced 32 Round Frame Asynchronous Vector Motors 0 18 kW 315 kW Description These IE2 efficiency round frame asynchronous induction motors are suitable for use with the Parker SSD Drives AC650V AC690 and AC890PX Modular ranges of Inverters in closed loop mode Featuring a durable rigid construction these motors are specially engineered for use in heavy industrial applications Featuring axial In Line force ventilation fan and 2048 ppr incremental encoder the round frame vector motor are suitable for general purpose closed loop control applications For applications requiring higher dynamic performance such as in printing or test rig applications the MA series square frame vector motors should be considered e Light Aluminium body up to and including 160 frame size Cast Iron contruction over 160 frame e P55 Protection as minimum e Foot or flange mounting options e Paint finished in Black e Insulation Class F IEC EN60034 1 e Auxiliary cooling fan allows low speed operation e 2048 ppr incremental encoder e 3x PTC thermistors embedded in motor s
41. tator Square Frame Asynchronous Vector Motors 0 75 kW 314 kW Description The MA series family of motors has been specially engineered to be suitable for high dynamic performance when used with a flux vector type controller AC890PX Modular AC690 and AC650V They permit operation in constant power at maximum speed up to 8000 min e Compact square frame format e Same frame dimensions as DC motors of similar power rating e Thermostat embedded in stator e Incremental encoder e IP23 or IP54 protection e Insulation Class F CEI EN60034 1 e Auxiliary cooling fan allows low speed high torque operation e High overload capability e Higher operating speeds AC890PX Modular Chassis Drive Related Products Options e Adjustable terminal box mounting position Holding brake IES efficicency Insulated bearings on 315 frame 8 Pole versions also available Options Terminal box mounting on right or left PTC thermister S vibration class IP55 protection Roller bearing on frame 100 Anti condensation heater 33 At Parker we re guided by a relentless drive to help our customers become more productive and achieve higher levels of profitabil ity by engineering the best gia sali ies tel apie CLIMATE CONTROL gippnpugsisuient FILTRATION ments tt ta looking al Key Markets Key Markets Key Markets Key Markets customer applications from e Aircraft engines e Agriculture e Aerospace e Food a
42. to 400 kW e 400 700 VAC AC input e Multi motor applications e Common DC bus power sharing hH AC Input Using special option 1 400 kW CS module running 3x110 kW CD sections ae AC890PX Modular Chassis Drive Technical Characteristics Active Front End AFE Regenerative drive solution for excess system energy and for regenerative applications With active input for elimination of supply harmonics with unity power factor e Power range to 2 MW e 4Q regenerative system e Unity power factor additional drives stages LCL Filter Parallel AC890PXP For power demands greater than 400 kW offered as pre built systems in either air or liquid cooled formats for single multi motor or AFE control AC890PX Series control module can control up to 3x sections of power modules to achieve power ratings of up to 2000 kW e AC or DC input supply e Motor control or AFE configuration ________ e Air cooled to 1200 kW advanced cooled to 2 MW AC Input _ M 12 18 Pulse Configuration 12 pulse Offered as a pre built system the 12 18 pulse configuration can be fi used in single motor applications where power quality and minimial supply harmonic distortion is critical e 400 690 VAC AC input e Power range to 1000 kW e Minimised input harmonics SD I hh Lda da lt UU UU S cee aed ee i j ji n 12 Pulse 18 Pulse 18 Pulse AC Input AL AC Input U AC Input U

Download Pdf Manuals