Home

Aqua SnakeEye™ OA-09 Extended Life NiMH Battery Operators

image

Contents

1. on this switch after connecting and powering the charger the charger may not function properly If this switch has already been turned on please ignore this step figure 7 2 Identify the following cable connection figure 8 for the charger located on the end of the OA 09 Extended Life NiMH Battery the Smart Charger TM12 10A2 figure 2 and the Universal AC adapter figure 3 figure 8 AQUA_OA_09V12 3 Connect the charger cable to the OA 09 Extended Life NiMH Battery charger cable making sure that the arrows lt line up This is very important as there is only one way to complete this connection 4 You MUST disconnect all of the output cables from the OA 09 Extended Life NiMH Battery before you power on the charger 5 Connect the Universal AC cable to the charger 6 Plug the AC adapter into the wall outlet 7 When the connection is complete you will notice 2 steady red lights on the charger 8 When you charge a fully depleted OA 09 Extended Life NiMH Battery the buzzer will beep 5 seconds for every 5 seconds time interval until the voltage reaches 12 5V This warning signal indicates that the OA 09 Extended Life NiMH Battery is NOT ready for use 9 When the OA 09 Extended Life NiMH Battery is fully charged one of the red lights on the smart charger will turn green 10 Alternate Charge Method You can also use the supplied 24V Car DC Adapter figure 4 in place of the AC Adapter to charge the OA 09
2. you hear 5 consecutive beeps this indicates that the OA 09 Extended Life NiMH Battery can power SnakeEye for another five minutes after which it will shut off At this time the OA 09 Extended Life NiMH Battery shall be recharged Please disconnect all of the output cables after use to prevent the OA 09 Extended Life NiMH Battery from damage cased by over discharging If you plan to store the OA 09 Extended Life NiMH Battery for an extended period of time it is recommended that you open the carrying bag and turn off the switch for battery charging control board figure 7 This will allow the battery to drain at a slower rate All rechargeable batteries will loose some of their charge in an idle state AQUA_OA_09V12 Warning N A PaE Do not short circuit the battery Disconnect all of the output cables to prevent the OA 09 Extended Life NiMH Battery from over discharging when not in use Fully charge the OA 09 Extended Life NiMH Battery before long term storage and always store the battery in a cool and dry location Avoid storing in a damp or humid environment It is recommended opening the carry bag and turning off the storage switch see figure 7 before long term storage If you turn off the storage switch remember to turn it back on when you plan to use OA 09 Extended Life NiMH Battery Only use the supplied AC power source and charger to charge the OA 09 Extended Life NiMH Battery Using other charger and or power
3. Aqua SnakeEye OA 09 Extended Life NiMH Battery Operators Manual Rev 1 2 AQUA_OA_09V12 VI Table of Contents Introduction Part List Getting Started Ready for Use Trouble Shooting Specifications AQUA_OA_09V12 I INTRODUCTION Congratulations on your purchase of the Aqua OA 09 Extended Life NiMH Battery When fully charged this wearable OA 09 Extended Life NiMH Battery will give you about 9 hours of uninterrupted use when connected to the SnakeEye Video Inspection Tool This OA 09 Extended Life NiMH Battery can also provide 12V DC for up to two other 12V portable devices using the supplied power output cables figure 6 When a second 12V device is connected the battery life will be decreased The combination of using one SnakeEye and another portable 12V DC device or two other portable 12V DC devices can not exceed 60 Watts This OA 09 Extended Life NiMH Battery can be attached to a waist belt and or worn around the shoulder or neck with the included adjustable shoulder strap for added convenience IMPORTANT NOTE Failure to operate and maintain the Aqua OA 09 Extended Life NiMH Battery in accordance with the instructions in this manual may result in damage to the unit damage to other personal property or personal injury Read this manual carefully and completely before operating the OA 09 Extended Life NiMH Battery and keep the manual on file for future reference CAUTION Use only the supp
4. Extended Life NiMH Battery Simply replace the Universal AC Adapter with the 24V Car DC Adapter and plug into the cigarette lighter in an auto This can be helpful if traveling from one site to another and you need the maximum battery capacity AQUA_OA_09V12 IV READY FOR USE Now with a fully charged OA 09 Extended Life NiMH Battery you are ready to connect the SnakeEye and or another 12V DC device If you don t use this OA 09 Extended Life NiMH Battery to power SnakeEye you can power up to two portable 12V DC devices The total power consumption combining using SnakeEye and or other 12V DC devices can not exceed 60 watts 1 To connect the SnakeEye to the OA 09 Extended Life NiMH Battery you will need 2 3 4 6 7 8 9 xww we N x x to have the supplied 5 foot SnakeEye to OA 09 Extended Life NiMH Battery cable figure 5 Assemble the SnakeEye for use Connect the 5 foot cable to the OA 09 Extended Life NiMH Battery Connect the other end of the 5 foot cable to the SnakeEye Turn on the SnakeEye and you are now ready to utilize the OA 09 Extended Life NiMH Battery for extended use of the SnakeEye When you are finished using the OA 09 Extended Life NiMH Battery make sure that you recharge the unit before storage to insure that it will be ready for use the next time it is needed If the low power warming LED on the front of the OA 09 Extended Life NiMH Battery turns red and
5. lied AC power source to charge the OA 09 Extended Life NiMH Battery Only use the OA 09 Extended Life NiMH Battery with a SnakeEye or another device that requires a 12V DC source Never charge or use the OA 09 Extended Life NiMH Battery in the rain or in water AQUA_OA_09V12 ll Part List You will find the following parts when you open this OA 09 Extended Life NiMH Battery 1 Battery Pack and Carry Bag figure 1 2 OA 09 01 Smart Charger TM12 10A2 figure 2 3 OA 09 02 Universal AC Adapter For Charger figure 3 AQUA_OA_09V12 4 OA 09 03 24V Car DC Adapter for Charger figure 4 5 One OA 09 04 5 Foot Cable from OA 09 Extended Life NiMH Battery to SnakeEye figure 5 6 Two OA 09 05 Output Cables for Other Portable 12V DC Devices figure 6 7 This User Manual AQUA_OA_09V12 Ill GETTING STARTED Though The OA 09 Extended Life NiMH Battery may have a small charge when you receive the unit it is recommended that the battery be fully charged before use to gain maximum use It will take approximately 10 hours to charge a fully depleted OA 09 Extended Life NiMH Battery CHARGING THIS EXTENDED LIFE NIMH BATTERY To charge the battery 1 If this is your first time to charge the OA 09 Extended Life NiMH Battery you need to open the carry bag and turn the storage switch on figure 7 Fail to turn on this switch will not allow the Extended Life NiMH battery to be charged properly If you turn
6. ry Material Ni MH Lead Free HHR900D applied 5 Discharging Current Continuous Maximum 5000 mA 6 Life Cycle gt 300 Cycles 7 Working Temperature Charging 32 F to 104 F 0 C to 40 C Discharge 14 F to 122 F 10 C to 50 C 8 Storage Time One Year when the storage switch is off and temperature is between 4 F to 95 F 20 C to 35 C 9 Stand by Time Two Months when the storage switch is on and temperature is between 4 F to 95 F 20 C to 35 C 10 Battery Cell Dimension 7 0in L X 3 5in D X 3 0in W 11 Weight 6 0 Lbs AQUA_OA_09V12 OA 09 01 Smart Charger TM12 10A2 Specification Charge Current 1A 2 Power on Indicator Red LED 3 Charge Indicators One dual color LED Red Charging Green Battery fully charged Flash Red Charge Failure 4 Charge Termination Mechanism 4 1 Negative Delta V Detected 4 2 Temperature rises higher then 0 7 degree C per minute 4 3 Zero Delta V for 12 Minutes All components are no Lead approval AQUA_OA_09V12
7. supply will automatically void product warranty Don t expose the OA 09 Extended Life NiMH Battery in fire or water Dispose of in accordance with all applicable laws and regulations Please contact your local recycle center for details V TROUBLE SHOOTING If the OA 09 Extended Life NiMH Battery will not operate the SnakeEye or other device make sure that the battery storage switch is on figure 7 If you turn on the storage switch and the green LED of OA 09 Extended Life NiMH Battery is on it indicates that the battery has enough power and is ready for use If the Green LED is not on you need to charge the OA 09 Extended Life NiMH Battery If after turning the battery storage switch on and it still will not operate the SnakeEye and other devices make sure that all of the cables are connected properly see section IV If after step 1 and 2 above are complete and it still will not operate the SnakeEye and other device make sure that the OA 09 Extended Life NiMH Battery is fully charged AQUA_OA_09V12 VI SPECIFICATIONS System structure SnakeEye Output connecter Battery Pack 3 party car cord cable oer Other device Output cable Car cord adapt Output cable AC Adapter p 22 i 24V Car DC e PPH 3 Converter i OA 09 Extended Life NiMH Battery Specification 1 Nominal Voltage 12V 2 Capacity 8 5AH 3 Charge Time 10 hours 1A charging current 4 Batte

Download Pdf Manuals

image

Related Search

Related Contents

Samsung 27" aukščiausios kokybės LED monitorius su itin siauru rėmu Vartotojo vadovas  T。T。/ 照明ユニッ ト施工説明書  ODYS 7“ DPF Touch  smc01a user guide.cdr  Bunn RL35 User's Manual  308-02-065 升级版灯带英文说明书图框  GTS® Manuel d`entretien, de fonctionnement et d`installation  Toshiba 55TL515U LED TV  grants international one-stop-portal  Untitled - Portal de Servicio Koblenz  