1. N IRON THE INDUSTRIAL NETWORK COMPANY 100 POE4 Unmanaged Industrial 4 Port Mid Span POE PSE User Manual amp Installation Guide Revised 2011 09 02 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net N IRON THE INDUSTRIAL NETWORK COMPANY Industrial 4 Port Mid Span POE PSE Installation Guide 100 POE4 Revised 2011 09 02 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net Copyright O N TRON Corp 2008 820 S University Blvd Suite 4E Mobile AL USA 36609 All rights reserved Reproduction adaptation or translation without prior written permission from N TRON Corp 1s prohibited except as allowed under copyright laws Ethernet is a registered trademark of Xerox Corporation All other product names company names logos or other designations mentioned herein are trademarks of their respective owners The information contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein Contact I
2. 2011 09 02 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net TYPICAL APPLICATION Factory Switch TRON 7014FX2 1 s 8 Utility Power 48VDC 48VDC SS N TRON N TRON 5 Amp 5 Amp m Wireless Devices POE Print Server poe amp RFID Reade WiFi tun Barcode Scanner CAT5e Cable CAT5e Cable with POE Receiving Dock Shipping Dock CONNECTING THE UNIT For 10Base T ports plug a Category 3 or greater twisted pair cable into the RJ45 connector For 100Base T ports plug a Category 5 or greater twisted pair cable into the RJ45 connector Connect the other end to the far end station The total length of cable should not exceed 100 meters Although power is being applied to the Ethernet port the power does not boost data on the lines TROUBLESHOOTING 1 Make sure the Power LED is ON 2 Make sure you are supplying sufficient current for the 100 POE4 and all the powered devices plugged into it Note The inrush current and steady state current is dependent on the power requirements of the powered devices plugged into the 100 POE4 3 Verify that the POE light is on solid for the port in question 4 Verify cabling used between stations The 100 POEF4 is a mid span PSE not a POE switch 5 Verify that cabling is Category 3 or greater for 10Mbit Operation Revised 2011 09 02 Phone 800 894 0412 Fax 888 723 4773 Web
3. be available in all locations When an advance replacement is provided and customer fails to return the original product to N TRON within fifteen 15 days after shipment of the replacement N TRON will charge customer for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED N TRON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS N TRON SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO OPEN REPAIR OR MODIFY THE PRODUCT OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY
4. www the red lion net Email info the red lion net FCC STATEMENT This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation 1s subject to the following two conditions 1 this device digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may caus
5. 10 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net N TRON 100 POE4 MID SPAN POE GROUNDING TECHNIOUES The grounding philosophy of any control system is an integral part of the design N Tron switches are designed to be grounded but the user has been given the flexibility to float the switch when reguired The best noise immunity and emissions 1 e CE are obtained when the N Tron switch chassis 1s connected to earth ground via a drain wire Some N Tron switches have metal din rail brackets that can ground the switch if the din rail is grounded In some cases N Tron switches with metal brackets can be supplied with optional plastic brackets 1f isolation is required Users may run a drain wire amp lug from the screw provided on the back face of the enclosure In the event the provided grounding screw has been lost care should be taken to limit the penetration of the outer skin by less than 1 4 Failure to do so may cause irreversible damage to the internal components of the switch Note Ensure the power supply is grounded properly before applying power to the grounded switch This may be verified by using a voltmeter to determine that DRAIN WIRE WITH LUGS there is no voltage difference between the power supply s negative output terminal TO KNOWN GROUNDING POINT and the chassis grounding point of the switch mm NONMETALLIC DIN RAIL MOUNT As an alternative grounding method
6. ACCIDENT FIRE LIGHTNING POWER CUTS OR OUTAGES OTHER HAZARDS OR ACTS OF GOD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW N TRON ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS LOSS OF INFORMATION OR DATA OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF N TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE DISCLAIMER Some countries states or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for personal injury so the above limitations and exclusions may be limited in their application to you When the implied warranties are not allowed to be excluded in their entirety they will be limited to the duration of the applicable written warranty This warranty gives you specific legal rights which may vary de
7. E V2 POE OFF Color Green Note Redundant power inputs will not balance the power load Only load from one power supply is used at a time Revised 2011 09 02 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net APPLYING POWER Top View CHASSIS GROUND N V Negative GND Return V Positive 46 54VDC V Negative GND Return V Positive 46 54 VDC f DETAIL 4 Unscrew amp Remove the DC Voltage Input Plug from the top header Install the DC Power Cables into the Plug observing polarity on unit Plug the Voltage Input Plug back into the top header Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot Turn the power on the wire Note It is only safe to turn the power on the wires after the wires have been secured to the 100 POE4 WARNING Inserting the input plug while the 48VDC is applied may cause arcing and damage the input connector permanently Verify the Power LED stays ON GREEN Note Either V or V2 can be connected to power for minimal operation For redundant power operation V and V2 plugs must be connected to separate DC Voltage sources Use wire sizes of 20 10 gauge The power cord should be limited to less than 10 meters in order to ensure optimum performance Recommended 48V DC Power Supplies similar to 100 240VAC N Tron NTPS 48 5 DC 48V 5A or N Tron NTPS 48 2 DC 48V 2A Revised 2011 09 02
8. OE4 is not powered down before disconnecting the Cat5E cable Revised 2011 09 02 5 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net Functional Overview The 100 POE4 industrial 4 port Mid Span POE PSE 1s designed to provide power over Ethernet for POE capable devices where running a power line 1s either not possible or not cost effective This feature allows an end user to power a POE camera wireless access point or any other POE capable device without the need for running separate wires for power This also allows the ability for a centralized battery backup for all these devices Key Features FE cE Q Compact space saving package IEEE 802 3af Compliant Four 10 100Base TX RJ 45 Ports DATA IN Four 10 100Base TX RJ 45 POE Ports DATA amp POWER OUT Unmanaged operation Extended Environmental Specifications 40 C to 85 C Operating and Storage Temperature Operating Humidity 10 to 90 Non Condensing Full Wire Speed Communications LED POE Status Indication Power Fault Status LEDs Up to 0 8 Gb s Maximum Throughput Industry Standard 35mm DIN Rail Mounted Enclosure Redundant power inputs 46 49 VDC Supports up to 15 4Watts per channel 13 Watts at the Powered Device PD Hardened metal DIN Rail Enclosure Revised 2011 09 02 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net PACKAGE CONTENTS Please make sure the pac
9. both V legs of the power input connector are connected to chassis internally on the PCB Connecting a drain wire to earth ground from one of the V terminal plugs as shown here will ground the switch and the chassis The power leads from the power source should be limited to 3 meters or less in length DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GROUNDING POINT If the use of shielded cables is required it is generally recommended to only connect the shield at one end to prevent ground loops and interfere with low level signals i e thermocouples RTD etc Cat5e cables manufactured to EIA 568A or 568B specifications are required for use with N Tron Switches METALLIC NONMETALLIC SHIELDED PATCH CABLE STP STP Note Strain relief boots not shown for clarity purposes In the event all CatSe patch cable distances are small i e All Ethernet devices are located the same local cabinet and or referenced to the same earth ground it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals Revised 2011 09 02 11 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications 0 232 0 005 5 89 0 1 27 CATSe CABLE 0 237 0 005 6 02 0 1 3 EIA 568B CATSe CABLE Revised
10. ctors 10 100BaseTX 3 5 8 89cm 1 489 3 78cm 3 53 8 96cm 0 7 Ibs 0 31kg 35mm 46 49 VDC 1 6 A 48 VDC under full load 30 mA 48 VDC under no load 27 Amp 1 5 ms 48 VDC under full load 24 Amp 1 5 ms 48 VDC under no load Less than 100 mV 20 10 AWG 40 C to 85 C 40 C to 85 C 10 to 90 Non Condensing 0 to 10 000 ft gt Cat 3 Cable gt Cat 5 Cable Eight 8 RJ45 TX Copper Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Revised 2011 09 02 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net N TRON Limited Warranty N TRON Corp warrants to the end user that this hardware product will be free from defects in workmanship and materials under normal use and service for the applicable warranty period from the date of purchase from N TRON or its authorized reseller If a product does not operate as warranted during the applicable warranty period N TRON shall at its option and expense repair the defective product or part deliver to customer an eguivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of N TRON Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the remainder of the initial warranty pe
11. e undesired operation Cet appareillage num rique de la classe A r pond a toutes les exigences de I interference canadienne causant des r glements d quipement L op ration est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interference re ue y compris l interference qui peut causer l op ration peu d sir e Revised 2011 09 02 14 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2000 US and Canada and is listed for use in Class I Div 2 Groups A B C D T4A EMI EN 61000 6 4 EN 55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN 61000 6 2 IEC 61000 4 2 ESD IEC 61000 4 3 RS IEC 61000 4 4 EFT IEC 61000 4 5 Surge IEC 61000 4 6 Conducted Disturbances Warranty 3 years from the date of purchase Revised 2011 09 02 15 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net KEY SPECIFICATIONS Physical Height Width Depth Weight DIN Rail Electrical Input Voltage Steady Input Current Steady Input Current Inrush Current Input Ripple Input Wire Size Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseT Conne
12. ith the end plates removed WARNING Do not work on equipment or cables during periods of lightning activity WARNING Do not perform any services on the unit unless qualified to do so WARNING Observe proper DC Voltage polarity when installing power input cables Reversing voltage polarity can cause permanent damage to the unit and void the warranty Revised 2011 09 02 4 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net HAZARDOUS LOCATION INSTALLATION REOUIREMENTS 1 This equipment is suitable for use in Class I Div 2 Groups A B C and D or unclassified or non hazardous locations only 2 WARNING Explosion Hazard Substitution of components may impair suitability for Class I Division 2 3 WARNING Explosion hazard do not disconnect while the circuit is live or unless the area is known to be non hazardous 4 WARNING Explosion Hazard Do not remove or replace the device unless power has been switched off or the area is known to be non hazardous 5 Use 60 75 C rated Copper wire 0 22Nm 2 inch lbs Tightening torque for field installed connectors 6 WARNING Install only in accordance with Local amp National Codes of Authorities Having Jurisdiction 7 Class I Div 2 installations require that all devices connected to this product must be UL listed for the area in which it is installed 8 WARNING Damage may occur to the RJ 45 port of the powered device PD if the 100 P
13. kage contains the following items 1 100 POE4 2 Instruction Sheet Contact your carrier 1f any items are damaged UNPACKING Remove all the eguipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warnings before beginning the installation WARNING Never install or work on electrical equipment or cabling during periods of lightning activity Never connect or disconnect power when hazardous gasses are present Revised 2011 09 02 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net DIN Rail Mounting Install the unit in a standard DIN rail Recess the unit to allow at least 2 of horizontal clearance for CATSe cable bend radius To install the unit to 35mm industrial DIN rail place the top edge of the included mounting bracket on the back of the unit against the DIN rail at a 15 angle as shown Rotate the bottom of the unit to the back away from you until it snaps into place To remove the unit from the 35mm industrial DIN rail place a flat head screwdriver into the release clip found at the bottom of the unit and apply downward force on the clip until it disengages from the bottom of the unit from the DIN rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle to completely remove the uni
14. nformation N TRON Corp 820 South University Blvd Suite 4E Mobile AL 36609 TEL 251 342 2164 FAX 251 342 6353 Revised 2011 09 02 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net GENERAL SAFETY WARNINGS WARNING Do not operate the equipment in the presence of flammable gasses or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard WARNING Ifthe equipment is used in the manner not specified by N TRON Corp the protection provided by the equipment may be impaired WARNING Do not perform any services on the unit unless qualified to do so Do not substitute unauthorized parts or make unauthorized modifications to the unit WARNING Do not operate the unit with the end plates removed as this could create a shock or fire hazard WARNING Properly ground the unit before connecting anything else to the unit Units not properly grounded may result in a safety risk and could be hazardous and may void the warranty See the grounding technique section of this user manual for proper ways to ground the unit WARNING Do not operate the equipment in a manner not specified by this manual ENVIRONMENTAL SAFETY WARNINGS WARNING Disconnect the power and allow to cool 5 minutes before touching ELECTRICAL SAFETY WARNINGS WARNING Disconnect the power cable before removing the end plates WARNING Do not operate the unit w
15. pending on local law GOVERNING LAW This Limited Warranty shall be governed by the laws of the State of Delaware U S A Revised 2011 09 02 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net
16. riod whichever is longer N TRON shall not be responsible for any custom software or firmware configuration information or memory data of customer contained in stored on or integrated with any products returned to N TRON pursuant to any warranty OBTAINING WARRANTY SERVICE Customer must contact N TRON within the applicable warranty period to obtain warranty service authorization Dated proof of purchase from N TRON or its authorized reseller may be required Products returned to N TRON must be pre authorized by N TRON with a Return Material Authorization RMA number marked on the outside of the package and sent prepaid and packaged appropriately for safe shipment Responsibility for loss or damage does not transfer to N TRON until the returned item is recetved by N TRON The repaired or replaced item will be shipped to the customer at N TRON s expense not later than thirty 30 days after N TRON receives the product N TRON shall not be responsible for any software firmware information or memory date of customer contained in stored on or integrated with any products returned to N TRON for repair whether under warranty or not ADVANCE REPLACEMENT OPTION Upon registration this product qualifies for advance replacement A replacement product will be shipped within three 3 days after verification by N TRON that the product is considered defective The shipment of advance replacement products is subject to local legal requirements and may not
17. t Revised 2011 09 02 Most N Tron products are designed to be mounted on industry standard 35mm DIN rail However DIN rail mounting may not be suitable for all applications Our Universal Rack Mount Kit P N URMK may be used to mount the 100 POE4 enclosures to standard 19 racks as an option Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net FRONT PANEL 100 POE4 O r p ja oe nd EEE IK 5 Z From Top to Bottom Power LED V1 POE POE is being applied on the respective port with V1 as a valid source of power V2 POE is being applied on the respective port with V2 as a valid source of power LEDs The table below describes the operating modes Port LEDs are for power supply status only and do NOT indicate link or activity LED O Green Valid Power 46 54 VDC is applied Invalid Power lt 46 VDC is applied or Power Bus Fault detected OFF No Power is applied to the device POE is being applied on the respective port with V1 as a valid source of power Blinking POE PD detected with improper power classification OFF POE is not being applied on the respective port from the V1 power input Green POE is being applied on the respective port with V2 as a valid source of power Blinking POE PD detected with improper power classification POE is not being applied on the respective port from the V2 power input PO
Download Pdf Manuals
Related Search
Related Contents
レトロフィットサービス(PDF:615KB) T22ML rev0105 Cuisinart CPC-600 pressure cooker Téléphone sans fil DE 2111 www.truvativ.com Hussefelt and Holzfeller Pedals Ascom d41 QRG ScanVue Lite User Guide - Industrial Electronic Engineers Inc. Service Unit eBudde Training Manual Air/Manual Hydraulic Bottle Jacks Copyright © All rights reserved.