1. General Display Local Resources Programs Experience Logon settings E Type the name of the computer or choose a computer from the drop down list Computer 192158110 Username admin Password Domain C Save my password Connection settings Save current settings or open saved connection On the General tab enter the system IP address Enter the administrator user name admin Enter the administrator password the default is codonics Click the Connect button CODONICS 17 NOTE Only one user can use Remote Desktop at a time If a second user connects to Infinity with Remote Desktop the first user will be logged out CAUTION When shutting down a PC connected to Infinity C with a Remote Desktop Connection make sure that you are not actually shutting down Infinity C Doing so could inadvertently disconnect other Infinity C users or interrupt drive recovery operations resulting in data loss Login Using Local Monitor Log On to Windows User name admin Password 20000000 1 Atthe Windows login enter the administrator user name admin 2 Enter the administrator password the default is codonics 3 Click the OK button 18 Infinity C Reference Guide System Configuration CAUTION Users not trained in network setup or DICOM configuration should seek professional assis
2. O CODONICS Infinity C Reference Guide Table of Contents Components UU UU T 1 gare 5 SmarnDriveGontigurati oM a 12 15 ER 16 VSEM CONIO AUO asein 19 BICOS Uo S 20 MOMONG OAI S NIME ETE EE 24 TEOUDIGSTIOOHPQ sionis 62250256226 5005509 20 62 05 98 o D3IRNIDEC odh4 0 002 tu0M0 do ao eos ca deseo 0 a 28 MET ER 29 CODONICS Components Unpacked Components EDICAL IMAGE SERVER C WW WR CAR Qc S WR m Wm V WA RAY WAT S coponics o mo chassis Main chassis key AC power adapter AC power cord Ethernet cable CODONICS SmartDrive Installation disc User s Manual disc Documentation Main Chassis Front 1 Power button 4 Disc drive 2 Mute button 5 Hard drives 3 Status lights 6 Front door 2 Infinity C Reference Guide Main Chassis Rear I oa L1 9 77 1 1 Power connector 3 Connector panel 2 Serial Attached SCSI SAS port CODONICS 4 Ethernet port 1 7 Serial port 5 Ethernet port 2 not used 8 USB 2 0 ports 6 VGA port Infinity C Referenc
3. a Publish this folder to the Web Share this folder Other Places ij My Computer My Documents a My Network Places Details CODONICS D Removable Disk File System 2 3 Run Configurator exe Infinity C Reference Guide Q IG 10 11 12 13 Oy 4 OF Configurator Basic Site Your Facility Name inc Locaic Purge Tempora Shs Minimum Temporary Space TB Maximum Conciarent T xport Associations Network P Albers ion Subnet Mask SMTP Sarver mail codonics com 12 catcway SMTP Username ec NWS Server surp Passwort System Name Cancel Enter the site name and site contact Select Dynamic or Static for the IP address Acquisition Type If Static was selected enter the system IP address and other network settings Make sure no spaces are in the System Name entry NOTE The Gateway IP address cannot be set to 0 0 0 0 A DNS Server entry is required for remote LogMeln support Select a locale Select the Purge Temporary Studies option if you want temporary studies to be automatically deleted when the system reaches 95 full If you want to set aside a minimum amount of temporary space enter an amount in tenths of a TB in the Minimum Temporary Space field Select a level of concurrent associations you want the system to try to use if exporting or SmartRouting studies Options are Serial One at a time Low Two to Three Medium Four
4. e BE System 10 1 100 106 Weh Viewer Storage NelworkSystem UPS M in Chassis Drives Tempcraturc 7 f 1H lotal Rallery 1 evel 107 Ay 10 1 100 106 100 0 40 39 0 C Notwork System Hosiname IP Address Subnet Mask Galeway Software Version Serial Number license Code 100 Free 2 7 TB gh Uscd 0 0 1H Mazin Chassis x n lt GMT 2003 INANITY JASFQOI 10 1 100 106 255 255 0 0 10 1 1 1 13 1 110C00037C 050 00075 155 Main Chassis 2 7TB 4 HDD 2 Click branches in the component tree to display status details CODONICS Fri Oct 23 9 37 25 Dashboard Status Information GMT 2009 gt gt gt lt Fri Oct 23 9 37 0 10 1 100 106 100 0 40 39 0 C 1 Storage capacity used 2 Network 3 UPS 4 Hard drives 5 System temperature gt mu a Fri Oct 23 9 37 jl SS GMT 2009 10 1 100 106 100 0 40 39 0 C 1 Processing status Infinity C is ready to process or is processing requests 2 Alert condition Infinity C can still process jobs but requires user attention 3 Fault condition Infinity C cannot process jobs and requires user attention 26 Infinity C Reference Guide Front Panel Status Lights O O al e t Power 5 Not used Hard drive activity 6 Hard drive status Network 1 activity 7 Hard drive power not u
5. e Guide Hardware Setup CAUTION Incorrect installation can result in system damage or loss of data Users not trained in computer hardware installation network setup or DICOM configuration should seek professional assistance Power Ethernet and SmartDrive 1 Place the main chassis on a solid level surface 2 Connect the power cord from the AC adapter CODONICS 3 Secure the power cord with the clip 4 Connect the AC power cord to the AC adapter and to a power outlet or uninterruptible power supply UPS optional Infinity C Reference Guide 0960 9 C 0900 290959 992905 6 Insert the SmartDrive Optionally program the SmartDrive refer to SmartDrive Configuration on p 12 CODONICS UPS Accessory 1 Insert the battery plug e oza 92096 006060000096 9999959 2 Connect the serial cable t
6. emote Desktop 1 From a PC on the network or a PC connected to the system using an Ethernet crossover cable start the Windows Remote Desktop Connection application NOTE If the PC does not have the Remote Desktop Connection application download the application from the Microsoft Windows website 2 Click the Options button 3 Remote Desktop Connection 5 jte Desktop nection General Display Local Resources Programs Experience Performance 3 Choose your connection speed to optimize performance LAN 10 Mbps or higher Allow the following Desktop background v Show contente of window while dragging Menu and window animation Themes v Bitmap caching 3 Onthe Experience tab change the connection speed to LAN 10Mbps or higher 16 Infinity C Reference Guide Remote Desktop Connection note Desktop finection General Display Local Resources Programs Experience Remote desktop size E Choose the size of your remote desktop Drag the slider all the way to the right to go fullscreen Less Y More Full Screen Colors True Color 24 bit 4 Note Settings on the remote computer might override this setting v Display the connection bar when in full screen mode 4 Onthe Display tab change the Color to True Color 24 bit or True Color 32 bit Remote Desktop Connection MM MM _
7. led System responses are slow Wait for jobs to complete Check the status lights The system shuts down Make sure you did not inadvertently shut down the system from the Remote unexpectedly Desktop Connection application If you did restart Infinity C and check its status using the System Status tool For additional assistance contact Codonics Technical Support A specific Windows Make sure that you are searching from your normal Windows desktop and not application cannot be found from the remote desktop System performance is slow Check System Status web page for possible problem Set PDU size to maximum of 128 KB on the Query Retrieve client and Store client NOTE For additional troubleshooting issues refer to the Infinity C User s Manual 28 Infinity C Reference Guide Shutdown Axe rrilri Administration 43 My Computer English Viewer 17 Run Japanese Viewer amp Windows Security System Status 543 Remote Support System Shutdown OKRE All Programs D 1 In the Start menu of the remote desktop or local monitor select System Shutdown Log Off o Disconnect System Shutdown jJ you sure that you want to shut down Shutdown 2 Click the Shutdown button registered and unregistered trademarks are the property of their respective owners Specifications subject to change without notice Patent Pending Copyright 2008 2010 by Codonics Inc P
8. o the UPS and to the serial port on the main chassis rear 0 Infinity C Reference Guide Sy 3 Connect the AC power cord to the UPS f N Gono o Db p B B AJ RE O w y 4 Connect the UPS power cord to a power outlet 00 og Bb Monitor Keyboard and Mouse Optional O 999 A 1 Connect the keyboard and mouse 950 0 69960600000 C 4 L 96990 4 TIR TA HDMI D C 000960560 9050600 eee 2 Connect the monitor NOTE It is recommended that the monitor power cord be connected to the same outlet as the main chassis or UPS power cord 10 Infinity C Reference Guide Hard Drive Installation Hard drives are factory installed in the order shown 11 SmariDrive Configuration 12 CAUTION Do not reconfigure or modify the software except as described in configuration tasks documented in this manual 1 Remove the SmartDrive from the main chassis 2 Connect the SmartDrive to a PC DA Edt View Favortes Tool Help T J 2 P Search 2 Folders address lt D File and Folder Tasks S profiles P Configurator Make a new folder
9. rinted in U S A Part Number 900 445 003 01 CODONICS 29
10. sed Network 2 activity not used Status Light Indication Power Blue Power on Hard drive activity Flashing amber Hard drive activity Hard drive power Blue Power on Hard drive status Off No disk activity CODONICS Green Disk activity Hed Hard drive fault 27 Troubleshooting Problem Solution Startup fails Check the power connection to back panel of Infinity C Check the UPS Verify the AC power cable is connected to the AC adapter and AC outlet Verify the AC adapter LED is on Verify that the SmartDrive is connected Login fails Verify the user name Verify the password case upper case and lower case Network not responding Check the system IP address and other network settings Verify that the network cable is connected to Ethernet port 1 upper Ethernet port Verify that the SmartDrive is connected DICOM station cannot Check all IP addresses and other network settings connect Check the AE Title and DICOM port in the Administration tool Ping the system from the DICOM station Verify that the network cable is connected to Ethernet port 1 upper Ethernet port Verify that the SmartDrive is connected One hard drive status light is Replace the hard drive red Multiple hard drive status Contact Codonics Technical Support lights are red Phone 1 440 243 1198 Toll Free 800 444 1198 USA only E mail support 9 codonics com Power supply module has Replace the power supply module fai
11. tance CAUTION Do not reconfigure or modify the software except as documented in this manual Users The system includes three user logins admin manager and operator The initial password for all three is codonics To change the passwords refer to the Infinity C User s Manual Date and Time Use the Windows Control Panel to set the date and time for the system N 19 O CODONICS DICOM Setup Allowing Access by DICOM Stations 4 9 5 22 1 the Administration tool Connection e User 3 P ord XXXXXXXX Database Infinity Cancel 2 Atthe login enter the administrator user name admin NOTE Entries in the User field are converted to uppercase automatically Enter the administrator password the default is codonics Click the OK button 20 Infinity C Reference Guide Oo rp 7 T inn File View Setup Control Help amp A 5 Click DICOM Stations 6 Click the Add button 21 22 DICOM stations Copy initial parameters from click Cancel if you want to keep the default parameters T Select the preconfigured station 8 Click the OK button DICOM Station s properties Identification Grant Import Export Kind Workstation Model Unknown Y Alias Station 1 DICOM parameters AE Title cr 3 Get IP address from incomming connection Secure connec
12. tion Private DICOM tags lt none gt Check IP Address at connection 9 Enter an alias name for the station 10 Enter the station s Calling AE Title 11 Enter the station s host name or IP address 12 Click OK 13 Add other stations as needed Infinity C Reference Guide oF Aliministration DICOM Stations Host lt lt automatic gt gt 104 Workstation CT Station 1 CT 1 192 168 1 100 104 14 When all stations have been added click the Save All button DxServer Administration A Save changes to DICOM Stations Yes Cancel 15 Click the Yes button Host Settings for Storing DICOM Studies Called AE Title TCP Port Description temp 104 Place studies in temporary storage perm 104 Place studies permanent storage NOTE The temp and perm Called AE Titles are default host settings and must be lower case to work properly Testing Store and Retrieve Store and retrieve operations should be tested before making Infinity C available for general use This entails storing a study from a DICOM station opening Study Manager on Infinity C to verify that the study was received then retrieving the study from the DICOM station For more information refer to the Infinity C User s Manual S 23 CODONICS Monitoring Status Detailed Status Information 1 Open the System Status Tool 24 Infinity C Reference Guid
13. to Five High Six to Seven Enter the e mail server information for system messages To manage Feature Keys click the Advanced tab CODONICS 13 14 rn sic Advanced f SmartRouting Feature Keys Add Delete Feature Keys Feature Key 0000VT1A0005 0100L195AH80 0250002G54MA O3JWS8LO00A0M 04L1B6TH8000 05002G4E TASO 068L000A0HU9 076212G00180 082 0 425000 09000A05GC8L 0AH2G00180N1 0B2821A00050 14 Click the Feature Keys subtab 15 To add a feature key click the Add button 16 17 18 19 20 21 Add New Feature Please enter Feature Key Enter the Feature key Click the OK button NOTE For information about the SmartRouting features refer to the Infinity SmartRouting Reference Guide Return to the Basic tab Click the Save button and close the window Disconnect the SmartDrive from the PC Insert the SmartDrive in the main chassis Infinity C Reference Guide Startup 11119 1 If there is a monitor installed press the monitor power button 2 If there is a UPS power on the UPS 3 Press the main chassis power button Wait five minutes for startup to complete indicated by six audible beeps If there is no local monitor refer to Login Using Remote Desktop on p 16 If there is a local monitor installed refer to Login Using Local Monitor on p 18 15 CODONICS Login Login Using R