        AIR-SURE LEAK DETECTOR - Retro
         Contents
1.    DESCRIPTION     Primarily intended as a tool to locate leaks in single ply and two ply membrane systems  including but not limited to  air barriers   vapor barriers  roofing systems  waterproofing and ground liners     Can be utilized during construction  prescriptive testing  and post construction   For commercial  industrial  institutional and residential applications   COMPOSITION AND MATERIALS     Air Sure Leak Detector body is comprised of powder coated steel  The test chamber is durable poly carbonate  with a closed cell   neoprene rubber seal     Material Safety Data Sheets  MSDS  for the Air Sure Test Solution are available from your local distributor upon request     DIMENSIONS    Leak Detector body  20 0 in  x 6 5 in  x 6 5 in   28 0 in  x 17 0 in  x 17 0 in   with Standard Dome Profile attached   14 0 pounds  6 4 kg    POWER SUPPLY     One  1  12V sealed lead acid gel battery  rechargeable    ACCESSORIES     Air Sure Leak Detector comes complete with Standard Dome Profile  4L Air Sure Test Solution  with four  4  250 mL dauber  bottles   Battery Charger  and Operator   s Manual     2  TECHNICAL DATA    APPLICABLE STANDARDS     Test method is in keeping with ASTM E 1186 98    Standard Practices for Air Leakage Site Detection in Building Envelopes and Air  Retarder Systems    method 4 2 7 Chamber Depressurization in Conjunction with Leak Detection Liquid      MATERIAL CONSIDERATIONS     Testing using the Air Sure Leak Detector  in conjunction with Air Sure Test So
2.  fumes or dust  Do not place the Leak Detector near    fire or extreme heat       Use of an attachment not recommended by the distributor may result in a risk of fire   electric shock  or personal injury     14    Optional Accessories    There are a variety of other test chamber profiles that can be used to test specific details and require the  hose attachment  Each end of the hose fits onto the adapters located on the profile and on the standard  dome  To use the hose attachment profiles  place the Leak Detector on a flat surface  such that the  standard dome chamber has a continuous seal to the surface  Place the hose attachment profile over the  test area  once Test Solution has been applied to the detail   Run the test as normal  holding the hose  attachment profile over the sample area  Contact your local distributor for a list of available profiles  or for  information on custom profiles        15    Storage and Transportation    In order to keep the Air Sure Leak Detector in optimal working condition  store the equipment when not in  use  and use caution when transporting the equipment  Follow the guidelines below     Storage    If you are storing the equipment in the recommended Air Sure Security Case  follow the packing  instructions on the case to ensure a stable environment for the equipment when not in use  If you are not  using the Air Sure Security Case  store the Leak Detector with the test chamber on the unit  The Leak  Detector and the Test Solution should b
3.  is required     Charging Care   When using the battery charger  adhere to the following safety guidelines      DO NOT OPERATE THE LEAK DETECTOR WHILE IT IS BEING CHARGED       The Leak Detector should be charged in a location where the temperature is between  10  C  50  F  and 40  C  104  F   Do not operate the charger outdoors       Guard against electrical shock by preventing body contact with grounded surfaces while  charging the Leak Detector       Do not expose the battery charger to any liquid or frozen liquid       An extension cord should not be used in conjunction with the charger  Use of an  extension cord in this manner could result in fire or electric shock       Do not operate the charger with a damaged cord or plug  If the cord or plug is damaged   have them replaced immediately by a qualified electrician       Do not operate the charger if it has received a sharp blow  been dropped  or otherwise  damaged in any way  It must be replaced       To reduce the risk of electric shock  unplug the charger from the power outlet before  attempting to perform any maintenance or cleaning  Once unplugged  the charger may  be wiped clean with a clean  damp cloth and allowed to dry before used again     Battery Use    Do not attempt to change the battery  or use non Air Sure batteries  The Air Sure warrantee does not  cover damage caused from using non Air Sure batteries and or battery chargers     If the battery is punctured  and the battery fluid comes into contact with th
4.  on  the headlight in the nose cone  will be activated  The corresponding Light Indicator on the faceplate will illuminate when the Light  Switch is activated     Note  The headlight should be used only to illuminate the test area and is not intended as  a replacement for any auxiliary lighting necessary to perform this  or any other  work     Air Sure Test Solution    Use only Air Sure Test Solution with the Leak Detector  The Air Sure Test Solution has been specially  formulated such that it will not have any adverse effects upon single ply waterproofing  roofing  or air  barrier membranes  or on the Leak Detector unit  Do not use the Air Sure Test Solution on    breathable     membranes  such as building wrap  as it will break down the surface tension of moisture on paper   causing it to pass through the building wrap     Do not use the Air Sure Test Solution to detect oxygen leaks     If the Air Sure Test Solution comes into contact with the eyes  flush eyes immediately with lukewarm  water  If irritation persists  contact your doctor     Before conducting any onsite testing using the Air Sure Test Solution  check the expiry date on the  shipping bottle to ensure that the Test Solution has not passed its expiry date  Even if the expiry date has  not been reached  ensure that the Test Solution is still functional before using it for onsite testing   Conduct a    test    using the Air Sure Leak Detector and Test Solution on a known leak area to ensure that  the Test Solutio
5.  present  Bubbles may also form and pop  quickly  A very large leak may not form a bubble  but  rather blow solution away from the detail  This may also  be caused by lack of solution on the testing area  The  movement of the solution in this fashion usually signifies  a leak  However  a retest is advised in this situation     When a leak has been identified  the test should be  halted immediately  letting the pressure within the test  chamber decrease before removing the machine from  the detail  The detail can then be marked for further  repair  or the bubble can be photographed if  documentation is required for the particular job        12    If the test procedure is followed correctly with the  machine in Auto Mode  the unit will automatically shut off  when a pressure differential of 500 Pa  2 0 inches of  water column  is reached     Record the test results     Note  This does not imply that the workmanship of the  detail is to the specifications of the particular job  nor  does it imply that the detail in question will not leak at a  higher pressure differential        Cleaning the Test Area of Residual Test Solution    Although testing has shown that the Test Solution causes no damage to the membrane or metal details  it  is essential that all residual test solution be removed from all working surfaces once testing has been  completed  Injury may occur by slipping on a surface that has had solution applied to it  Wipe the detail  with a clean  dry cloth  to remove tes
6.  the casing and chamber of the Leak Detector with a clean cloth  For best results  use a furniture  polish on the casing  NEVER use gasoline  other petroleum based products  or any solvent for cleaning  the Leak detector     17    Retro Specs Limited Warrantee for the United States and Canada    What Does this Warrantee Cover     Subject to the exclusions contained below  Retro Specs Ltd  warrants its leak detection equipment to be  free from defects in materials and workmanship under normal consumer usage for the period s  outlined  below  This limited warrantee is a consumer   s exclusive remedy  and applies as follows to new Air Sure  Products and Accessories purchased by consumers in the United States or Canada  which are  accompanied by this written warrantee     Products and Accessories    Products Covered Length of Coverage    Products and Accessories as defined   One  1  year from the date of purchase  above  by the first consumer purchaser pf the  product        Exclusions    Normal Wear and Tear  Periodic maintenance  repair and replacement of parts due to normal wear and  tear are excluded from coverage     Batteries  Only batteries whose fully charged capacity falls below 80  of their rated capacity and  batteries that leak are covered by this limited warrantee     Abuse  amp  Misuse  Defects or damage that result from   a  improper operation  storage  misuse or abuse   accident or neglect  such as physical damage  cracks  scratches  etc   to the surface of the pr
7. AIR SURE LEAK DETECTOR    USER MANUAL       Welcome    Thank you for purchase of the Air Sure Leak Detector  We are pleased that you have selected our  equipment for your membrane testing needs        Retro Specs Ltd   Box 69   Grosse Isle  MB  ROC 1G0    204 322 5081    rskevinknight gmail com       www retrospecslitd com       Air Sure and Retro Specs are registered in the US Patent and Trademark Office and the Canadian  Intellectual Property Office        Retro Specs Ltd  1997  2000  2005  2006  2011     The information contained in Retro Specs Ltd  user manuals is believed to be correct at the time of  printing  Retro Specs Ltd  reserves the right to change or modify any information or specifications without  notice  The contents of Retro Specs Ltd  user manuals are provided    as is     Except as required by  applicable law  no warrantees of any kind  either express or implied  including  but not limited to  the  implied warrantees of merchantability and fitness for a particular purpose  are made in relation to the  accuracy  reliability or contents in this manual     Caution  Changes or modifications made to the Leak Detector that are not expressly approved by  Retro Specs Ltd  will void the user   s authority to operate the equipment     Contents    Safety and General Information            0 0 0 0 cee eee 4  Introduction to the Air Sure Leak Detection System               0    eee eee 6  Getting Started  os  oc ey be ib ek Bey ob te ee eit iS bed eee Vest eed ae ee Pe
8. e See eg Eee Ra ee RE RW a Ae SAEC DR i ee eo Bae ees Ee 18  Specifications  cortas ut ege agis opes God ped a acs  Pain cael e od Sa du a Rae he Melee atacand aon 20    Safety and General Information    IMPORTANT INFORMATION ON SAFE AND EFFICIENT OPERATION OF YOUR AIR SURE LEAK  DETECTOR  DO NOT ATTEMPT TO OPERATE THE LEAK DETECTOR UNTIL YOU HAVE  THOROUGHLY READ AND UNDERSTAND ALL OPERATING INSTRUCTIONS AND SAFETY  PROCEDURES CONTAINED IN THIS MANUAL  FAILURE TO COMPLY WITH THESE OPERATING  INSTRUCTIONS AND SAFETY PROCEDURES MAY RESULT IN ACCIDENTS INVOLVING FIRE   ELECTRIC SHOCK  AND OR SERIOUS PERSONAL INJURY  SAVE THIS MANUAL AND REVIEW IT  FREQUENTLY FOR CONTINUED SAFE OPERATION     General Use      Use the Leak Detector for the correct purpose  Do not use it for anything other than what it was  designed to do  Use only Air Sure Test Solution with the Leak Detector  Use of an attachment  not recommended by the distributor may result in a risk of fire  electric shock  or personal injury       Never use the Leak Detector in an explosive atmosphere  Normal sparking of the motor could  ignite flammable liquid  gases  fumes or dust  Do not place the Leak Detector near fire or  extreme heat       Use safety glasses when the Leak Detector is in operation     Do not operate the tool when tired  or while under the influence of drugs  alcohol or medication     Keep the work area clean  Cluttered or dirty areas that have been improperly cleaned of residual    Test Solution are pot
9. e ia 7  What s mthe Box oos ld RD bap een eats deta deat dot bep udo AR arg wig aed oobi ee 7  Gharging the  Battery  9 21 2 ag cade tee atra ae deal eap e ua Mae Ag ee eee A A pae dd 8  Battery USE AER TET 8  Getting to Know Your Air Sure Leak Detector                  0 0200 cece eee 9  Hardware Components 22 esu dia haere hd tus deba dor Pmt Lue Deed depo eed dd et doa 9  ControliPanel wie dipae os Rap eel Ed PR x uv ba e ra E Ed NE d ait xus gd 10  Air Sure  Test Solutiofi   see ERRARE LR p eR AR ER MUERE PANIER 11  Using the Air Sure Leak Detector            0 0    ce e 11  Cleaning the Area Around the Detail Being Tested           lll lees 12  Applying Test Solution to the Sample Area                00000 ce lh 12  Placing the Leak Detector Over the Detail              llle 12  Activating the Leak Detector 2  2 02  ce eR a Ru RR Re ed PA Rud RR 13  Cleaning the Test Area of Residual Test Solution               00 0000 cee ee 14  Optional  ACCessorles  oisi ke ei eae A Rae ca ie RN E erede RE E 15  Storage and Transportation o oerscsci biert te Saacan at pE he 16  Storage oet poi eat te ca a T e e tacet a e a S eho d qo 5 EE re e E oe tana 16  Hoisting   e etes aom Lu idc op Rabe eens e aea eh as 16  Transportation Dy AIP ick  dee cs E ERREUR UR AARAU ha Dee Shee I EL MEER 16  Maintenance uos REIR Sac RSG RR eg mb EA pe CECI RR RS EA 17  Maintenance  asyr ciii depan AE Vad a UA EAS ee ea PASS CREE FETA 17  Gleaning  qx Ole dni Aa ze an Rc Ee Rc RA ode 17  Warrante    v o
10. e skin  wash the skin  immediately with soap and water  and seek medical attention  If the fluid gets into the eyes  flush eyes  immediately with lukewarm water for at least ten minutes  and seek immediate medical attention  Return  the defective Leak Detector to an authorized service center or to your local distributor     Getting to Know Your Air Sure Leak Detector    Hardware Components    The test chamber is the clear  plastic dome located on the end of the Air Sure Leak Detector  The black   rubber strip that runs along the bottom of the test chamber is the chamber seal  The nose cone is  located inside the test chamber  and is attached to the Leak Detector body  Contained within the nose  cone are the pressure switch  and the nose cone light  To remove or change the test chamber  first  locate the ring lock  which surrounds the nose cone  and turn it in a counterclockwise motion  Once the  ring lock is removed  the test chamber simply pulls off     Located within the Leak Detector body are the motor  the battery  and circuitry  The control panel is  located on the face of the Leak Detector body  The trigger switch is found on the handle  which is  attached to the body     Control Panel    It is important to be familiarized with the control panel before operating the Air Sure Leak Detector     Charger Connection          Charging Indicator    Battery Power Level  Indicator    Pressure  Indicator    Auto Mode    Switch and w  Indicator    Light Switch and  Indicator    Au
11. e stored in a dry and secure area   out of reach of children     Hoisting    Follow local hoisting and rigging regulations when lifting equipment to the test destination  DO NOT lift the  equipment by carrying it up an unstable incline  ladder or scaffolding     Transportation by Air    There are no components inside the Leak Detector which restrict transportation by air  The following is a  list of particulars that will aid you in passage through customs     Batteries are sealed lead acid gel    Serial number is located on the side of the machine body    Country of origin is located on the control panel    The weight of the Leak Detector is approximately 15 pounds  6 8 kg      16    Maintenance    Maintenance    Check damaged parts  Discontinue using the Leak Detector if any part of the unit appears damaged   Refrain from further use until the unit is properly repaired or replaced at an authorized service center   Never open or disassemble the Leak Detector     Some parts of the Air Sure Leak Detector may be serviced without bringing the unit to the distributor s  service depot       Burned out light bulb in the nose cone  replace with a 6 3V 0 15A  size T 374  incandescent light  bulb  Unscrew the lens cover counterclockwise to remove  Once the lens cover has been  removed  unscrew light bulb counterclockwise  Replace bulb  Screw lens cover  clockwise  back  onto the Leak Detector    For problems that are not listed above  contact your local distributor     Cleaning    Wipe
12. ential hazards       Avoid dangerous environments  Do not work on wet and or slippery surfaces  Do not carry the  Leak Detector up steep inclines or ladders  Follow the proper hoisting guidelines for your area       Do not overreach  Keep proper footing and balance at all times  Do not use the Leak Detector  while on a ladder or on unstable support     Storage and Maintenance      Store the Leak Detector and Test Solution in a dry and secure area   out of reach of children      Keep the handle and the body of the Leak Detector dry  clean and free from oil and grease   Always use a clean cloth when wiping the Leak Detector  Never use brake fluids  gasoline   petroleum based products  or any strong solvents for cleaning      Never open or disassemble the Leak Detector      Check damaged parts  Discontinue using the Leak Detector if any part of the unit appears    damaged  Refrain from further use until the unit is properly repaired or replaced at an authorized  Service center     Air Sure Test Solution      Do not use the Air Sure Test Solution to detect oxygen or other gas leaks       Do not use the Air Sure Test Solution on  breathable  membranes  such as building wrap       If the Air Sure Test Solution comes into contact with the eyes  flush eyes immediately with  lukewarm water  If irritation persists  contact your doctor        Battery and Charging    Do not operate the Leak Detector while it is being charged     Use only the battery charger provided with the Leak Detecto
13. lution  will not damage the membrane system when  the equipment is used as intended     Air Sure Test Solution should not be applied to plastic resin building wraps     3  USE    PREPARATORY WORK     The sample area selected should be wiped clean of dirt  grit  dust or debris  Test area should not be hot  from torching   frosted   extremely wet  and should be free of ice  Testing can be performed on seams  joints  and penetrations in the membrane     20    METHOD   Air Sure Test Solution is applied liberally to the area being tested  The test chamber is placed over the sample area  and the Leak    Detector activated  Contact between the Test Solution and test chamber should be avoided  Bubbles in the Test Solution indicate  the presence of a possible leak     4  AVAILABILITY AND COST    AVAILABILITY   Air Sure Leak Detector is available worldwide  usually shipped from stock  Contact Retro Specs Ltd  for a list of distributors   COST     Current price list available from local distributor     5  WARRANTEE  The information contained herein is the best available relating to the Air Sure Leak Detector  and the recommendations contained    herein are based upon information believed to be reliable  Limited warrantee covers all parts and labor costs resulting from defects  in materials or workmanship for a period of one  1  year     6  MAINTENANCE    CLEANING     Test chamber and machine casing should be wiped clean with a damp cloth  Furniture polish may be used on the machine casi
14. m  please contact your local  distributor        Getting Started    What   s in the Box    Your Air Sure Leak Detector comes equipped with a battery already installed  battery charger  Air Sure  Test Solution  and four bottles with daubers  You can purchase other accessory items and profiles for  maximum performance     To purchase other Air Sure Leak Detector accessories and  profiles  contact your local Air Sure distributor        Charging the Battery    New machines are shipped with batteries partially charged  Before using your Air Sure Leak Detector   you should charge the battery  using the following instructions     1  Plug the battery charger into the Leak Detector  The socket is located on the face of the control  panel        2  Plug the other end of the charger into the appropriate electrical outlet     3  A full recharge can be achieved in approximately three  3  hours  Although the built in circuitry will  prevent overcharging  it is recommended that the charger be disconnected after this time  To  reduce the risk of damage to the charger cord  pull it by the plug when disconnecting the charger   Do not step on the cord  or subject it to damage or stress  Disconnect the charger from the power  supply when not in use  As the batteries are sealed lead acid gel batteries  they are not subject to  the effects of memory  and may be charged within any level of charge remaining  The Air Sure  Leak Detector is designed to achieve approximately 130 tests before recharging
15. n still    oubbles     see Using the Air Sure Leak Detector      10    Using the Air Sure Leak Detector    There are five steps in correctly performing a test with the Air Sure Leak Detector     1 Clean the area around the detail being tested   2  Apply Test Solution to the sample area    3  Place the Leak Detector over the detail    4 Activate the Leak Detector    5 Clean the test area of residual Test Solution     Cleaning the Area Around the Detail Being Tested    Ensure that the test area is free of dirt  dust and debris  The test area should not be hot  from torching    frosted  or extremely wet  slight dampness around the test area will not compromise the results of the  test   The area being tested should be free of ice  which may act to    plug    the leak     Applying Test Solution to the Sample Area    Apply the Test Solution to the sample area using the dauber included with the 250 ml bottles  When  applying the Test Solution  ensure the entire sample area is covered with a wet film of solution  In the  case of a penetration  ensure the entire area is covered  In the case of a seam or joint  ensure that there  is solution pushed into the seam or joint  Do not overapply Test Solution  the Test Solution has been  overapplied if the Test Solution has formed a froth or foam over the sample area instead of a thin film      The Air Sure Test Solution is specially designed to cling to membranes and metal details  However   testing of the detail should be conducted immedia
16. ng   Do not use gasoline  petroleum based products or solvents on the Air Sure Leak Detector     CHARGING    Air Sure Leak Detector is designed to perform approximately 100 tests before recharging if the battery is required  A full recharge  can be achieved in approximately three  3  hours  Although the built in circuitry will prevent overcharging  it is recommended that  the charger be disconnected after this time     LIGHT BULB     Nose cone light bulb is a 6 3V 0 15  size T 374  incandescent light bulb     7  TECHNICAL SERVICES  Technical support is available from Retro Specs Ltd  Call 204 322 5081   Specification assistance     Site advice and recommendations     8  RELATED REFERENCES   ASTM E 1186 02   PWGSC National Master Specification   Section 07271 Air Barriers  Descriptive Proprietary     Section 07272 Air Barriers  Performance     Canada Mortgage and Housing Corporation Guidelines for Delivering Effective Air Barrier Systems  ASTM STP 1422 A New Protocol for the Inspection and Testing of Building Envelope Air Barrier Systems          21    
17. oduct  resulting from misuse   b  contact with liquid  water  rain  extreme humidity or heavy perspiration  sand   dirt or the like  extreme heat  or food   c  use of the Products or Accessories for commercial purposes or  subjecting the Product or Accessory to abnormal usage or conditions  or  d  other acts which are not the  fault of Retro Specs  are excluded from coverage     Use of Non Air Sure Products and Accessories  Defects or damages that result from the use of Non   Air Sure branded or certified Products  Accessories  Electronics or other peripheral equipment are  excluded from coverage    Unauthorized Service or Modification  Defects or damages resulting from service  testing  adjusting   installation  maintenance  alteration  or modification in any way by someone other than Retro Specs  or its  authorized service centers  are excluded from coverage    Altered Products  Products or Accessories with  a  serial numbers or date tags that have been removed     altered or obliterated   b  broken seals or that show evidence of tampering   c  mismatched board serial  numbers  or  d  nonconforming or non Air Sure housings  or parts  are excluded from coverage     Who is Covered     This warrantee extends only to the first consumer purchaser  and is not transferrable     18    What Will Retro Specs do     Retro Specs  at its option  will at no charge repair  replace or refund the purchase price of any Products or  Accessories that does not conform to this warrantee  We may 
18. r  Use of another charger may    damage the unit  may cause serious injury  and will void the warranty  The charger was provided  for use only with this Leak Detector  To reduce the risk of injury  do not charge any other  batteries  or any other piece of equipment  with this battery charger       Guard against electrical shock by preventing body contact with grounded surfaces while charging  the Leak Detector       To reduce the risk of electric shock  unplug the charger from the power outlet before attempting to  perform any maintenance or cleaning  Once unplugged  the charger may be wiped clean with a  clean  damp cloth and allowed to dry before used again       If the battery is punctured  and the battery fluid comes into contact with the skin  wash the skin  immediately with soap and water  and seek medical attention  If the fluid gets into the eyes  flush  eyes immediately with lukewarm water for at least ten minutes  and seek immediate medical  attention  Return the damaged Leak Detector to an authorized service center or to your local    distributor     Do not expose the battery charger to any liquid or frozen liquid     To reduce the risk of damage to the charger cord  pull it by the plug when disconnecting the    charger  Do not step on the cord  or subject it to damage or stress       An extension cord should not be used in conjunction with the charger  Use of an extension cord  in this manner could result in fire or electric shock       Do not operate the charger 
19. t solution  Wash area with water and wipe dry  Check the surface by  running your hand along the test area  If the test area is slippery to the touch  then repeat the cleaning  procedure until the surface is no longer slippery  It is the responsibility of the tester to remove all residual  Test Solution        Note  Prior to using the Air Sure Test Solution  ensure that the Test Solution has not passed its expiry  date  and is functioning as intended  The solution should be tested on a    known    leak  if the solution does  not bubble  it has expired     13    Notes on Using the Air Sure Leak Detector  When using the Air Sure Leak Detector  always  adhere to the following safety guidelines       When using the Leak Detector  ensure that the pressure reference port  located on the  nose cone exterior  remains uncovered throughout testing  Be careful not to cover the  port with your finger when running the machine          Use the Leak Detector for the correct purpose  Do not use it for anything other than what  it was designed to do       Always employ appropriate safety measures while using the Leak Detector  use safety  glasses when the Leak Detector is in operation  do not operate the Leak Detector when  tired  or while under the influence of drugs  alcohol or medication  and do not use the  Leak Detector while on a ladder or on unstable support       Never use the Leak Detector in an explosive atmosphere  Normal sparking of the motor  could ignite flammable liquid  gases 
20. tely after application of the solution in order to achieve  optimum results     Take care not to spill the Test Solution  Secure the cap back onto the dauber bottle when not in use to  avoid spilling Test Solution           11    Placing the Leak Detector Over the Detail    Center the chamber over the detail  holding the unit firmly against the membrane  When the seal is in  continuous contact with the substrate  the machine is ready for activation  It is not absolutely necessary to  achieve a perfect seal between the test chamber and the membrane  as the machine will adjust for any  extraneous leakage that may occur     When placing the chamber over the detail  avoid contact between the Test Solution and the chamber seal   If there is solution under the seal  bubbles may form at the seal  producing a false test result  If this  occurs  a retest should be performed in order to achieve optimum test results        Activating the Leak Detector       Once the chamber has been correctly placed over the test area  the machine is ready for activation   Begin the test by pulling and holding down the trigger switch located on the handle  The test can be  stopped whenever necessary by releasing the trigger switch     When the test is run  if the solution around the test area bubbles  a leak is present  If the solution  does not bubble  the detail is airtight     Careful observation is important as bubbles of different e    sizes can form anywhere within the test area where  solution is
21. to Mode Switch and Indicator  When the Auto Mode switch is engaged  the pressure  differential created by the Leak Detector can increase to a maximum of 500 Pa  When the Auto   Mode switch is disengaged  the pressure differential created by the Leak Detector can increase to  a maximum of approximately 2 500 Pa  When the Auto mode Indicator is lit  the Auto mode  switch is engaged     Note  Auto Mode    on    is the default setting on the Leak Detector     Pressure Indicator  The pressure sensor within the main body of the Leak Detector is set to  approximately 500 Pa  2 0  water   When the pressure differential across the test chamber  reaches this level  the Leak Detector will sound an alarm  the Pressure Indicator light will  illuminate  and the unit will automatically shut off indicating the completion of the test  provided the  Auto mode switch is the default    on    position      Battery Power Level Indicator  The Battery Power Level Indicator light will remain lit when the  battery is at the required level for operation  As the battery begins to wear down  the Battery  Power Indicator light will flash  indicating that the battery requires recharging  As the battery  continues to decrease in energy  the light will begin flashing more slowly     Charging Indicator  The Charging Indicator will become illuminated when the battery charger is  plugged into the Leak Detector  and the battery is receiving a charge     Light Switch and Indicator  When the Light Switch is turned
22. use functionally equivalent  reconditioned refurbished pre owned or new Products or Accessories     How to Obtain Warrantee Service or Other Information     Contact your local distributor  You will receive information on how to ship the Products or Accessories  at  your expense  to an Air Sure authorized repair center  To obtain service  you must include   a  a copy of  your receipt  bill of sale or other comparable proof of purchase   b  a written description of the problem   and  c  your address and telephone number     What Other Limitations Are There     ANY IMPLIES WARRANTEES  INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTEES OF  MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE  SHALL BE LIMITED TO THE  DURATION OF THIS WARRANTEE  OTHERWISE THE REPAIR  REPLACEMENT  OR REFUND AS  PROVIDED UNDER THIS EXPRESS LIMITED WARRANTEE IS THE EXCLUSIVE REMEDY OF THE  CONSUMER  AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTEES  EXPRESS OR IMPLIED    IN NO EVENT SHALL RETRO SPECS BE LIABLE  WHETHER IN CONTRACT OR TORT  INCLUDING  NEGLIGENCE  FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT OR  ACCESSORY  OR FOR ANY INDIRECT  INCIDENTAL  SPECIAL OR CONSEQUENTIAL DAMAGES OF  ANY KIND  OR LOSS OF REVENUE OR PROFITS  LOSS OF BUSINESS  OR OTHER FINANCIAL  LOSS ARISING OUT OF OR IN CONNECTION WITH THE ABILITY OR INABILITY TO USE THE  PRODUCTS OR ACCESSORIES TO THE FULL EXTENT THESE DAMAGES MAY BE DISCLAIMED BY  LAW     19    Air Sure Leak Detector Specifications    1  GENERAL 
23. with a damaged cord or plug  If the cord or plug is damaged  have  them replaced immediately by a qualified electrician       Do not operate the charger if it has received a sharp blow  been dropped  or otherwise damaged  in any way  It must be replaced       Do not operate the charger outdoors       Disconnect the charger from the power supply when not in use     Introduction to the Air Sure Leak Detection System    The Air Sure Leak Detection System is an effective  efficient and affordable testing system designed to  find leaks in single and two ply membranes used in all applications  When used in conjunction with visual  inspection  it provides an accurate reflection of the quality of installation of the membrane  and will assist  in determining whether the completed system is in adherence with installation specifications and building  codes     When a test is performed  the Air Sure Leak Detector will indicate whether there are leaks in the test  sample  It is a simple pass fail test  Areas where the membrane has been penetrated or damaged   fasteners and masonry ties   or where membrane continuity has been compromised  seams and joints   are just some of the details which can be tested using the Leak Detector  The Air Sure Leak Detector  allows for the testing of the quality of workmanship quickly  efficiently  and on the job site  with little or no  disruption to the critical path of construction     If you have any questions regarding the Air Sure Leak Detection Syste
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
VPAP™ ST VPAP™ S AutoSet CS™ S9™ Auto  Manual  設計変更ガイド  Samsung Samsung Armani-SAMSUNG Bruksanvisning  Best U102E User's Manual  www.cs.swan.ac.uk  User Manual for Android  Sanyo Xacti VPC-WH1YL User's Manual  ・アクション ニ フルアクション ・電 源 二 (本体)単三アルカリ乾電池X3本  HDX HDXMPN Use and Care Manual    Copyright © All rights reserved. 