User`s Manual Professional Rack Mount UPS PR3000

image

Contents

1. CyberPower The Power To Control the Power User s Manual Professional Rack Mount UPS PR3000 ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT www cyberpowersystems com CyberPowe wer To Control the Power TABLE OF CONTENTS SAFETY WARNINGS vase dee 3 BLOCK DIAGRAM uaa coe sessoneateceniteestareseenceasenrecenitesenared 4 INSTALLATION E ee ee 4 z uVesurm 4 HOW TO DERTERMINE THE POWER REQUIREMENTS OF YOUR zem 4 ESTIMATE POWER 5 HARDWARE 5 BASIC OPERTAIOD een ee ee eee eee eee 8 FRONT PANEL eee sees seat eaeenas 8 REAR PANEL n nn 9 TROUBLESHOOTING scitis opcional ade a n temi Hep 12 TECHNICAL SPECIFICATION 5er Radar m Lb tp Rxu REIHE 13 DEFINITIONS FOR ILLUMINATED LED INDICATORS 14 BATTERY HEPLAGEMEDBL E edt 15 BATTERY REPLACEMENT 16 LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE 18 PR3000 Guaranteed Uninterruptible Power System SAFETY WARNINGS This manual contains important safety instructions Please read and follow all instructions
2. ME mc TERTI GEESE CEA TEER 30 CEA Coe A Li To E 120 MAX20A c5 Saral Pot Serial Port OUT A tI Cf NU PRIHARY 7 WW D G3 Fsoanzsv 8 o OUT PUT 48Vv ITI IN PUT 48V 777 BATTERY PACK a AVR Indicator This LED indicates that the UPS is operating in automatic voltage regulation mode When the led is illuminated continuously it indicates input over voltage and the UPS unit bucks the voltage When the led is flashed in rotation it indicates that the UPS unit is boosting input voltage CyberPower The Power To Control the Power REAR PANEL DESCRIPTION Circuit Breaker Reset for Overload Protection Re settable circuit breakers provide optimal overload protection INFLUI Battery Backup and Surge Protection Outlets Provides two battery powered surge protected and AVR outlets for connected equipment and insures uninterrupted K operation of connected equipment during a power failure Provides a battery powered surge protected and AVR 0 outlet for the most critical connected equipment and insures N 7 1 e uninterrupted operation of connected equipment during a s ODO power failure Hu When the UPS is overloaded the other two minor outlets will not provide r to equipment Communication Protection Ports Ethernet RJ 45 Network Protection Ports protect s
3. carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate e Ihe AC power outlet must be installed near the ups and must be easily accessible e Attention risk of electric shock Disconnecting this unit from the power mains does not remove the risk Voltage may still be present from the battery pack The battery pack quick connectors should be disconnected before peforming maintenance or service work on the UPS e When replacing the batteries use the same number and type of batteries e Do not open or mutilate the battery or batteries Electrolyte is harmful to the skin and eyes e Abattery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles Never short circuit the battery terminals CyberPower yb Power To Control the Power BLOCK DIAGRAM INSTALLATION UNPACKING Inspect the UPS upon receipt The box should contain the following 1 UPS Unit 1 User s Manual 2 Rack Mount Brackets 2 Stands 1 PowerPanel Plus Software Disk 1 PowerPanel Software Disk 1 Telephone Cable 2 Serial Interface Cables DB 9 1 Serial to USB cable HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Insure that the equipment plugged into the five battery power supplied o
4. it returns to on line operation If the C UPS fails the self test please recharge the battery for 4 hours and perform another self test If it fails after recharging the battery please replace the battery Battery Indicators 5 This indicator shows a visual indication of the battery charge If battery capacity is under 20 no indicator LED will illuminate Za and UPS starts beeping PR3000 Guaranteed Uninterruptible Power System Loa ad Level Indicators Rg H e This indicator shows a visual depiction of the UPS load The load indicator LED will turn orange if the load is between 80 and 100 If the load is under 2096 no indicator LED will illuminate Power On Indicator gm This LED is illuminated when the utility condition is normal and the UPS outlets are providing clean power free of surges and spikes Battery Indicator This illuminates during utility failure indicating that the battery is Supplying power to the battery power supplied outlets D AN PN e Z D A m T INPUT 48v BATTERY PACK AC INPUT EON ERES D 7 pa P wu W 4 AL A a F M f T ML Ys M j e w we TEF i N 1 4 if Y x Hi fi P N P i Ex p j SZ AA M j cary CUN gy dr a RESET I Jl ees Y die F ar o fA rem
5. ASTE and must be disposed of properly Contact your local government for more information about proper disposal and recycling of batteries STORAGE First turn off your UPS and disconnect its power cord from the wall outlet Disconnect all cables connected to the UPS to avoid battery drain To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to insure battery life If the battery remains uncharged for an extended period of time it may suffer permanent loss of capacity 17 CyberPower The Power To Control the Power LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE By purchasing a CyberPower PR3000 in the United States or Canada the original end user referred to as the Initial Customer receives a Limited Warranty and Connected Equipment Guarantee from Cyber Power Systems USA Inc for ease of reading referred to as CyberPower Limited Warranty The Initial Customer receives an express limited warranty referred to as the Limited Warranty for the CyberPower PR3000 referred to as the Product Connected Equipment Guarantee CyberPower provides the Initial Customer with protection in the event that the Product is not free from defects in materials and workmanship and certain equipment connected to the Product is damaged the Connected Equipment Guarantee If you are an Initial Customer you are asked to read the following term
6. DICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES CyberPower does not sell the Products for use in high risk activities The Product is not designed or intended for use in hazardous environments requiring fail safe performance including the operation of nuclear facilities aircraft navigation or communication systems air traffic control weapons systems life support or medical applications or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities CyberPower does not authorize use of any of its products use in any High Risk Activities ANY SUCH USE IS IMPROPER AND IS A MISUSE OF CYBERPOWER PRODUCTS The Limited Warranty and the Connected Equipment Guarantee are governed by the laws of the United States and the State of Minnesota without reference to conflict of law principles The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded Contact Information CyberPower s address is 5555 12th Ave East Suite 110 Shakopee MN 55379 and its phone number is 952 403 9500 or 877 297 6937 toll free CyberPower is the warrantor under this Limited Warranty You may also co
7. Equipment by manufacturer and model Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and the name of the power 20 PR3000 Guaranteed Uninterruptible Power System utility supplier for the location of the Connected Equipment and Request a Return Materials Authorization RMA 4 Pack and ship the Product to CyberPower and if requested the item s of Connected Equipment a repair cost estimate for the damage to the Connected Equipment and all claim forms that CyberPower provides to you Show the RMA number on the shipping label or include it with the product Initial Customer shall prepay all shipping costs must pay the cost of the repair estimate and is responsible for packaging and shipment CyberPower s Duties CyberPower will inspect and examine the Product and the item s of Connected Equipment or at CyberPower s election your written statement and repair cost estimate for those item s You must return the product for inspection If the damage to Connected Equipment is covered by the Connected Equipment Guarantee CyberPower will in addition to Limited Warranty remedies for the CyberPower Product itself repair or pay the costs of repair or replace the Connected Equipment or at the option of CyberPower as permitted by law pay to the Initial Customer the Agreed Damage Amount up to the aggregate limits stated below for all item s of Initial Cus
8. e the UPS plugged into an AC outlet at all times To store your UPS for an extended period cover it and store with the battery fully charged Recharge the batteries every three months to insure battery life 10 To connect auxillary battery pack a Remove the protection cover on the UPS rear panel b Connect the black wire and the red wire of the Battery Pack to the negative black terminal and the positive red terminal of the PR3000 respectively See Figure 1 Note Due to the large current make sure to connect the positive to positive and the negative to negative Otherwise it may cause a short circuit and the unit may be irreversibly damaged PR3000 Guaranteed Uninterruptible Power System Figure 1 Connecting PR3000 with Battery Pack Battery Pack Postive Red Terminal Negative Black Terminal a CyberPo The er OW the er BASIC OPERATION FRONT PANEL DESCRIPTION mu um m PR3000 Yd 2 a Ros e um Sn SS i T ERED E L d Ogee oO CA i BATTERY SS Power Switch Press the power button to turn the UPS ON or OFF ON OFF Test Switch The PR UPS performs a self test automatically when power on If the UPS passes the test
9. ent must have been directly plugged into and properly connected to the Product in its original condition which was properly operated when a Power Disturbance passed through the Product and i exhausted the protection capacity of the CyberPower Product or ii damaged the CyberPower Product Further the Connected Equipment Guarantee does not apply if the Product has been operated in a failure mode or not in compliance with the operating instructions and manual or if the Connected Equipment has not been operated in compliance with the instructions and manuals of its manufacturer vendor CyberPower s total liability under this Connected Equipment Guarantee is limited to the Agreed Damage Amount defined below Making a Connected Equipment Guarantee Claim To make a Warranty claim for damage to Connected Equipment under the Connected Equipment Guarantee you must do the following 1 Provide reasonable proof of purchase for example a sales receipt that establishes you as the Initial Customer of the Product 2 Call CyberPower at 952 403 9500 or 877 297 6937 toll free write to CyberPower at 5555 12th Ave East Suite 110 Shakopee MN 55379 or e mail CyberPower at clains cyberpowersystems com within ten 10 days of the date of the event for which you wish to make a claim for warranty service 3 When you contact CyberPower identify the Product the Purchase Date the Serial Number of the Product and identify the item s of Connected
10. l free write to CyberPower at 5555 12th Ave East Suite 110 Shakopee MN 55379 or e mail CyberPower at clains cyberpowersystems com within ten 10 days of the event for which you want to make a claim 3 When you contact CyberPower identify the Product the Purchase Date and the Serial Number for the Product and request Return Materials Authorization RMA information 4 Pack and ship the Product to CyberPower as instructed in your RMA Show the RMA code on the shipping label or include it with the Product You MUST prepay all shipping costs and you are responsible for packaging and shipment CyberPower will inspect and examine the Product within ten 10 days of receipt If the Product is not as warranted CyberPower will repair or replace the Product and return it to you at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required CONNECTED EQUIPMENT GUARANTEE The Initial Customer is protected for the lifetime of the Product against certain losses due to the Product s defective material or workmanship that is directly i e no daisy chain and properly connected to equipment connected to the Product Connected Equipment subject to certain terms and limitations provided below The Connected Equipment Guarantee is not fi
11. nput voltage for output regulation while input voltage is from 15 to 26 under nominal AVR Max buck 13 of input voltage for output regulation while input voltage is from 8 to 26 ove nominal Utility Failure The UPS is providing battery power to the Battery backup outlets charge within a few minutes Overload Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and restart the UPS Overload Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and restart the UPS Surge Protection Malfunction Power surge has damaged the unit Please contact CyberPower 14 PR3000 Guaranteed Uninterruptible Power System BATTERY REPLACEMENT Contact your dealer or call the CyberPower Technical Support in this manual for information on battery replacement Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Servicing the battery can only be performed by trained personnel knowledgeable of batteries and their precautions Keep unauthorized personnel away from batteries CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present the risk of electrical shock Do not dispose of batteries in a fire as they may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the ba
12. ntact CyberPower on the Internet at www cyberpowersystems com 23
13. on 2 you wish to use the software connect the enclosed serial interface cable to the serial port on the UPS and an open serial port on the computer If you would like to use USB interface please connect the USB adapter with the serial cable then connect the USB adapter to your computer 3 With the UPS unit off and unplugged connect your computer monitor and any other devices into the battery power supplied outlets DO NOT plug a laser printer copier space heater vacuum paper shredder or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit CyberPower 4 TM wer To Control the Power To surge protect a network connection connect a network cable from the wall jack outlet to the IN jack of the UPS Then connect a network cable from the OUT jack on the UPS to the network device Plug the UPS into a wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e g refrigerator copier etc Avoid using extension cords If used the extension cord must be rated for 30 Amps Depress the power switch to turn the unit on The power on indicator light will illuminate Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically recharge To maintain optimal battery charge leav
14. on an AC Power Line on properly installed grounded and code compliant 120 volt power lines in the United States and Canada or a Power Disturbance on standard telephone land lines PBX telephone equipment lines ethernet lines or coaxial cables when properly installed and connected 3 Damage from fire flood wind rain rising water leakage or breakage of plumbing or abuse misuse or alteration of either the Surge Suppressor or the Connected Equipment 4 22 PR3000 Guaranteed Uninterruptible Power System Damage from any circumstance described as excluded above with respect to the product Exclusion of Consequential and Other Damages The sole and exclusive remedies of the Initial Customer are those provided by the Limited Warranty and Connected Equipment Guarantee CyberPower excludes any liability for personal injury under the Limited Warranty and Connected Equipment Guarantee CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property EXCEPT FOR AND ONLY FOR the specific limited agreement of CyberPower to provide certain warranty benefits regarding Connected Equipment under the Connected Equipment Guarantee loss of profits business interruption loss of information or data NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you DO NOT USE FOR ME
15. onds and turn the UPS on This should reset the unit The unit is not providing battery power The serial cable is not the cable that was provided with the unit You must use the cable included with the unit for the software 12 PR3000 Guaranteed Uninterruptible Power System TECHNICAL SPECIFICATIONS Capacity VA 3000VA Capacity Watts 2200W Voltage Range 85 150Vac Frequency Range 47 63Hz On Battery Output Voltage Pure Sine Wave at 120Vac 5 On Battery Output 60 Hz Frequency Transfer Time Typical Overload Protection On Utility Circuit Breaker On Battery Internal Current Limiting urge Protection and Filtering Lightning Surge Protection Internet Ready hysical Total of UPS Receptacles Maximum Dimensions 2U Rack 2 Weight 165 122 5 Sealed Maintenance Free Lead Acid Battery 8 Typical Recharge Time Indicators Power On Using Battery AVR Load Level Battery Level Audible Alarms On Battery Low Battery Overload nvironmental Operating Temperature 32 F to 95 F 0 C to 35 C Operating Relative Humidity 0 to 95 NON CONDENSING Power Panel Plus Software 13 TM The Power To Cantral the Power CyberPowe DEFINITIONS FOR ILLUMINATED LED INDICATORS On Off On Off On Off Set Long Beep Flash Condition AVR Max boost 13 of input voltage for output regulation while input voltage is from 8 to 15 under nominal AVR Max boost 26 of i
16. pplies to written and oral express warranties State or Provincial law may adjust the terms of the Limited Warranty or the Connected Equipment Guarantee or the State or Province may impose additional obligations or additional implied warranties To the extent necessary to comply with those laws the terms of the Limited Warranty and the Connected Equipment Guarantee should be read to adjust to those requirements only to the extent necessary to comply with such local law The Limited Warranty and the Connected Equipment Guarantee Do Not Apply Unless The Initial Customer 1 Has properly connected the Product and the Connected Equipment to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code ANS NFPA 70 without the use of any adapters extension cords of other connectors 2 Has provided a suitable and proper environment for use and installation of the Product and Connected Equipment 3 Has properly installed and operated the CyberPower Product and Connected equipment 4 Has operated the Product at all times within the limitations on the Product s VA capacity as stated in this User Manual CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following 1 Loss of or damage to data records or software the restoration of data or records or the reinstallation of software 2 Damage from causes other than Power Disturbances as defined above
17. rranty or Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product NOTE Some States do not allow limitations on how long an implied warranty lasts so the above limitation may not 18 PR3000 Guaranteed Uninterruptible Power System apply to you To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty Exclusive Remedies Under Limited Warranty Your exclusive remedy and CyberPower s sole obligations are as follows for the Product If a the CyberPower Product you purchased and still own is defective in material or workmanship under this Limited Warranty or any applicable warranty imposed by law and b all Limited Warranty requirements have been met CyberPower will repair or replace the Product if it proves to be defective in material or workmanship during the Warranty Period Making a Limited Warranty Claim To make a Limited Warranty claim on a Product you must do the following 1 Complete and return the CyberPower Warranty Registration Card or provide reasonable proof of purchase for example a sales receipt that establishes you as the Initial Customer the original end user consumer purchaser of the Product and prove that the Product was purchased within three 3 years of the event for which you want to make a claim for warranty service 2 Call CyberPower at 952 403 9500 or 877 297 6937 tol
18. rst dollar coverage CyberPower s obligation 19 CyberPower The Power To Control the Power is reduced by any amounts that Initial Customer is entitled to recover from other sources regarding the Connected Equipment including insurance other warranty or extended warranty coverage whether or not the Initial Customer makes a claim for recovery including but not limited to a claim under any applicable insurance other warranty or extended warranty To be covered under the Connected Equipment Guarantee a you must notify CyberPower within ten 10 days of the event for which intend to make the Connected Equipment claim b the Product must have been defective in materials or workmanship and such defect must have directly and proximately caused the damage c the Limited Warranty requirements have been met except that the three year limitation of the Limited Warranty does not limit the Connected Equipment Guarantee which is for the lifetime of the Product d none of the limitations or exclusions on warranty coverage apply other than the three year limit e the Connected Equipment must have been damaged by a transient spike or surge a Power Disturbance on an AC power line on properly installed grounded and code compliant 120 volt power lines in the United States and Canada or by a Power Disturbance on properly installed standard telephone equipment lines Ethernet lines or coaxial cables and f the Connected Equipm
19. s and conditions carefully before using the Product By using the Product you consent to be bound by and become a party to the Limited Warranty and Connected Equipment Guarantee If you do not agree to the terms and conditions of the Limited Warranty and Connected Equipment Guarantee you should return the Product for a full refund prior to using it REGISTRATION CyberPower requests that you complete and return the Warranty Registration Card enclosed with the Product or register the Product at its website www cyberpowersystems com to establish that you are the Initial Customer of the Product and therefore entitled coverage under the Limited Warranty and the Connected Equipment Guarantee Registration is not required for Limited Warranty or Connected Equipment Guarantee coverage but note if you do not complete a registration card you will be required to provide proof of purchase as described below to have the benefits of the Limited Warranty and Connected Equipment Guarantee LIMITED WARRANTY CyberPower warrants to you the Initial Purchaser that the Product will be free from defects in material and workmanship for three years from the date of original purchase subject to the terms of this Limited Warranty Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose if applicable to the Product is limited in duration to the period of ownership by the Initial Customer This provision shall NOT create any Implied Wa
20. s of shipping the Product and the Connected Equipment to and from CyberPower for inspection shall be borne solely by the Initial Customer CyberPower reserves the right to negotiate the cost and choose the facility at which any repairs will take place and CyberPower must be notified and approve any repair facility before any Connected Equipment is serviced Any repair or modification of the Connected 21 CyberPower The Power To Control the Power Equipment or the Product by a facility or entity not approved by CyberPower voids this Connected Equipment Guarantee If CyberPower determines in its sole discretion that it is impractical to ship the damaged equipment to CyberPower CyberPower may designate in its sole discretion an equipment repair facility to inspect and estimate the cost to repair such equipment The cost if any of shipping the equipment to and from such repair facility and of such estimate shall be borne solely by the Initial Customer Damaged equipment must remain available for inspection until the claim is finalized Whenever claims are settled CyberPower reserves the right to be subrogated under any existing insurance policies the claimant may have CONDITIONS COMMON TO THE LIMITED WARRANTY AND THE CONNECTED EQUIPMENT GUARANTEE The Limited Warranty and the Connected Equipment Guarantee are the only and the exclusive express warranty of CyberPower with respect to the Product This exclusion of other express warranties a
21. t least one piece to overload of equipment Wait 10 seconds reset the Outlets do not circuit breaker and then turn the UPS on provide power to equipment Recharge the unit for at least 4 hours Unit has been damaged bya Contact CyberPower at surge or spike tech cyberpowersystems com The UPS does Batiery is not fully charged Recharge the battery by leaving the UPS not perform plugged in at least 4 hours expected Contact CyberPower about replacement runtime batteries at tech cyberpowersystems com Turn the UPS off Wait 10 seconds and then turn the UPS on Battery is slightly worn out The on off switch is designed to prevent damage by rapidly turning it off and on The unit is not connected to The unit must be connected to a 110 120v an AC outlet 50 60Hz outlet Contact CyberPower about replacement The UPS will not turn on The battery is worn out batteries at tech cyberpowersystems com Only the individual Backup power outlet provides power to equipment Press the Self Test button to recover the other four outlets Connect the serial cable to the UPS unit and an open serial port of your computer You must use the cable that came with the unit The serial cable is not connected PowerPanel or The serial cable is connected PowerPanel to the wrong port Plus is inactive all icons are gray Try another serial port of your computer Shutdown your computer and turn the UPS off Wait 10 sec
22. tandard network cables TOCA 10 PR3000 Guaranteed Uninterruptible Power System Dual Serial Ports The PR3000 provides two serial ports to allow O 300 C connection and communication between the UPS and Serial Porti erial Port I two computers See Figure 2 This allows the PRIMARY simultaneous shutdown of two computer systems These interfaces are also compatible with the UPS service provided by Windows 2000 Windows NT Windows XP Windows Server 2003 and Mac OS 10X The Primary computer with PowerPanel Plus installed is the computer that you will use to control the UPS and make any change to the operation of the UPS The Secondary computer with PowerPanel installed is unable to exhibit any control over the UPS When there is a power failure the Primary computer will start to shutdown after a user controlled delay Once the Primary computer is shutdown the UPS will signal the secondary computer and initiate a shutdown The secondary computer will then shutdown Once the secondary computer has completed its shutdown the UPS will power off Serial Il Secondary Serial Part I Primary Primary Computer Secondary Computer Install PowerPanel Plus Install PowerPanel Figure 2 Dual Serial Port and Software Installation l1 CyberPower The Power To Control the Power TROUBLESHOOTING Problem Possible Cause Circuit breaker is tripped due Tum Poon unplug a
23. tomer s Connected Equipment The Agreed Damage Amount for all items of Initial Customer s Connected Equipment shall be the lesser of the amount determined under Clause 1 or 2 below reduced by any amounts described in Clause 3 below 1 The fair market value of the Connected Equipment as established by the lower of a the average price the same or similar items are being sold for on E bay b the price list of Orion Blue Book on the date of occurrence or if such price list is no longer published a published or announced price list reasonably selected by CyberPower or c the lowest price the same or similar items can be purchased for in the United States or 2 The aggregate ceiling amount for all Connected Equipment CyberPower PR3000 350 000 00 3 The amount s of all payment you have or are entitled to receive from insurance other warranties extended warranties or from other sources or persons for the Connected Equipment or damage to such equipment so that CyberPower s maximum liability shall be reduced to reflect all such other payments or sources of recovery If CyberPower replaces the connected equipment or pays to the Initial Customer the Agreed Damage Amount the Initial Customer shall transfer all item s to CyberPower without warranty by the Initial Customer but free of lien or other interest CyberPower reserves the right to inspect the Product the Connected Equipment and the site where the event occurred All cost
24. tteries Release electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery 1 Remove all watches rings or other metal objects Only use tools with insulated handles Do not lay tools or metal parts on top of battery or any terminals Wear rubber gloves and boots Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit 15 CyberPower wer To Control the Pow BATTERY REPLACEMENT PROCEDURE 1 Remove the right side 2 Remove the two retaining front panel screws of the cable protection cover then remove the cover 3 Disconnect the black and 4 Remove the four red cable 5 Pull the battery pack out from the unit 6 Take out the battery 16 PR3000 Guaranteed Uninterruptible Power System 7 Slide a new battery pack into the unit Assemble the screws cover cable and front panel in the reverse sequence of above steps 8 Recharge the unit for 4 8 hours to ensure the UPS performs expected runtime REMINDER Batteries are considered as HAZARDOUS W
25. utlets does not exceed the UPS unit s rated capacity 3000VA 2200W for PR3000 If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 If the power requirements of your equipment are listed in units other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The below equation only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any one time Users should expect usage requirements to be approximately 60 of the maximum value PR3000 Guaranteed Uninterruptible Power System TO ESTIMATE POWER REQUIREMENTS 1 Watts W x 2 0 VA or Amps A x 120 VA 2 Add the totals up for all pieces of equipment and multiply this total by 0 6 to calculate actual requirements There are many factors that can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s Capacity HARDWARE INSTALLATION 1 Your new UPS may be used immediately upon receipt However recharging the battery for at least four hours is recommended to insure that the batteries are fully charged Charge loss may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet The unit will charge in both the on as well as the off positi