1. 16 The Cyclo 04 DMX may be programmed and operated with any lighting control device that is compatible with the USITT DMX standard This section describes how to operate the system with a controller See DMX protocol on page 20 for specific control values Connecting a DMX control device Connect a data cable from the Cyclo 04 DMX to the control devices data output If the control device does not have an RJ 45 socket then you may need to purchase or wire an XLR to RJ45 converter For wiring information see Creating a data link on page 9 SETTING THE FIXTURE TO DMX OPERATION DMX operation is enabled by setting pin 10 on the DIP switch to OFF The DIP switch can be accessed by loosing the cover access screw do not remove it completely and sliding open the access plate as shown in the following illustration Cyclo 04 DMX user manual Control address selection The Cyclo 04 DMX requires 4 DMX control channels The DMX address also known as the start channel is the first control channel used It is a logical address to which control instructions are sent In this way a controller can send instructions to a fixture or fixtures at a particular address For example when using four channels of control data the Cyclo 04 DMX reads the data on the start channel DMX address and the next three channels If the DMX address is set to 100 the Imager uses channels 100 101 102 103 and 104 Be sure to allow adequate cha
2. INTENSITY CONTROL The intensity of the individual colors can be set from minimum to maximum on channels 1 to 4 Cyclo 04 DMX user manual 19 DMX PROTOCOL Start code 0 Channel Value Percent Function 1 White intensity 0 2 0 Tube off 3 252 1 99 Intensity 1 gt 100 253 255 100 Intensity 100 2 Red intensity 0 2 0 Tube off 3 252 1 99 Intensity 1 gt 100 253 255 100 Intensity 100 3 Green intensity 0 2 0 Tube off 3 252 1 99 Intensity 1 gt 100 253 255 100 Intensity 100 4 Blue intensity 0 2 0 Tube off 3 252 1 99 Intensity 1 gt 100 253 255 100 Intensity 100 20 Cyclo 04 DMX user manual SPECIFICATIONS CvcLo DMX PHYSICAL R E 2 ME e ER HO Ra 1190 x 98 x 88 mm 50x 4 x 3 7 in WEI SIE ues NIE er ERU PRI EIU EO seed Ver A e 6 7 kg 14 8 lbs Shipping dimensions nerea 1210x 115 x 95 mm 51 x 4 8 x 4 in Shipping Weight 5 ren aa RET TQ E Rp USE 7 1 kg 15 7 Ibs Fitur color uui lp EE EE ORAS ere REIS RANDE IP N Grey INSTALLATION Orientation A e eer TROIS o RR eus any Minimum free space around fixture when installed 25 mm 1 inch SOURCE Approved lamp type eee eee eee ee OSRAM T5 FH 28 watt tubes Light souree rra ads T5 tubes 3x28W Expected lamp life i dotado boa ads bed Sy T led 20000 hours POWER IAC POWER ved eate dr EE TR EMEN EN ES 198 V 254 V 50 60 Hz Maximum power and current 230 V 50Hz 0 56 A 128 watts AC Input lt a EE Ee e EnstoNet I
3. 5 sec pr state On Off 1 10 speed 10 sec pr state On On 1 30 speed 30 sec pr state OFF crossfade 0 ON crossfade 50 OFF Run program ON Pause program OFF Master ON Slave 10 ON Stand Alone mode Table 1 DIP switch settings in stand alone mode PROGRAM SELECTION DIP switch 1 to 4 each controls a single tube and these DIP switches can be combined to activate more than one tube If DIP switch 7 is set to OFF crossfade 0 then the tube will turn fully off before it fades in or alternatively when more tubes are selected the next tube will fade in If DIP switch 7 is set to ON crossfade 50 the tube will only fade down to 50 before it fades to full again or alternatively when more tubes are selected the next tube will fade in when the first reach 100 and they will meet at 50 MASTER SLAVE When a fixture is set to master DIP switch pin 9 is off it will transmit a synchronizing signal to slave fixtures over the data link whenever it changes to the next scene Slave fixtures DIP switch pin 9 is set on only change scenes when they receive synchronization signals from the master fixture The slave program will be as set by its DIP switch so to have a master and a slave run the same program their DIP switch settings have to be the same apart from the Master Slave setting The synchronization signal is the same as used by other Martin Architectural products so this enables the stand alone fun
4. in series The internal wiring of the fixtures carries AC power through the fixture Male and female Ensto connectors are provided at opposite ends of the fixture for input and output cables AC power is connected into the fixture via the female Cyclo 04 DMX user manual 7 EnstoNet Installation System socket and out to the next fixture via the male socket at the other end of the fixture Power cabling and connectors are not supplied with the Cyclo 04 DMX but cabling and connectors in a range of configurations can be ordered from your local Ensto distributor or the following connectors and cables are available from your Martin dealer ENSTO 3 pole 16A 250V male connector o n 00008 P N 05347202 ENSTO 3 pole 16A 250V female connector o n senunssunnn rruna P N 05327202 ENSTO male female cable 15 cm 5 9in 0 0 0 eee eee P N 11501019 Be sure to refer and comply with local standards Some common AC cable configurations are Wire EU Wire US Pin Marking brown black live L or 1 blue white neutral N yellow green green ground um Cyclo 04 DMX fixtures can be powered in series with other Cyclo 04 DMX fixtures of the same type When doing this be sure to use a power cable that is able to handle the 0 56A that is drawn by each fixture in the series Data linking multiple fixtures You need to create a data link if you are going to be Operating multiple Cyclo 04 DMXs in a synchro
5. 15 cm 5 9in 2 6 eee ee eee P N 11501019 XLR male to RJ 45 converter 2 0 eee eee eee P N 11840087 XLR female to RJ 45 connector s s u nauuna P N 11840086 CATS network cables 2 m 6 5 ft x 50 pieces o ooococoooocccoccc P N 91611044 CATS network cables 5 m 16 4 ft x 30 pieces P N 91611045 CATS network cables 10 m 32 8 ft x 15 pieces P N 91611045 Cyclo 04 DMX user manual 4 Martin www martin architectural com e Olof Palmes All 18 e 8200 Aarhus N e Denmark Tel 45 8740 0000 e Fax 45 8740 0010
6. 2 1 110 0 0 3 35 J 67 99 131 1639 195 227 259 291 323 3551387 4199 451 483 0 0 1 0 0 4 36 68 1009 132 164 196 228 260 292 324 356 388 420 f 452 484 i i i o o 5 37 69 1019133 1659 197 2291261 2931325 357 389 421 453 485 0 1 1 0 0 6 38 70 1029134 166 198 230 262 294 326 358 390 422 454 486 1 1 1 0 0 7 39 71 1039135 1679199 231 263 295 327 359391 4239 455 487 OO O 7 MO 8 40 72 1049136 1681200 2321264 2961328 360 392 424 456 488 1 0 0 1 0 9 41 J 73 1059137 1699 201 233265 297 329 361 393 4251457 489 0 1 0 1 0 10 42 74 1069138 1709 202 234 266 298 330 362 394 426 458 490 i SID ola e 11 43 75 1079139 171 203 235 267 299 331 363395 427 459 491 ojop1p1jo 12 44 76 1089140 1729 204 236 268 300 332 364 396 428 f 460 492 1 0 1 1 0 13 45 77 1099141 1731205 237 269 301 333 365 397 4299 461 493 0 dl 14 46 78 110 142 174 206 238 270 302 334 366 398 430 f 462 494 11111110 15 47 79 111 143 1751207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 2401272 304 336 368 400 432 464 496 Iolo ala 17 49 f 81 1139145 1771209 241 273 3051337 3699401 4339 465 497 0 1 0 0 1 18 50 f 82 1149146 1781210 242 274 306 338 370 402
7. 434 466 498 1 1 0 0 1 19 51 83 1159147 179211 243 275 307 339 371 403 435 f 467 499 eJpop1poJa 20 52 84 1169148 1801212 2441276 308340 372 404 436 f 468 500 1 o 1 0 1 21 53 J 85 1179149 1811213 245 277 3091341 3739 405 437 469 501 0 1 11 0 1 22 54 86 118 150 1829214 246 278 310 342 374 406 438 470 502 4 19 9 ola 23 55 87 119 151 183 215 247 279 311 343 3751407 4391471 503 0 0 0 1 1 24 56 88 1200152 1841216 248 280 3121344 376 408 4409 472 504 1 0 0 1 1 25 57 89 1219153 1859217 2491281 313 345 377 409 441 473 505 ode id 26 58 90 122154 1861218 2501282 314346 3781410 442 f 474 506 1 1 0 1 1 27 59 91 1239155 1879219 251 283 315 347 3799 411 4439 475 507 0 0 1 1 1 28 60 92 1249156 1881220 252 284 316 348 380 412 444 476 508 pop 39 29 61 93 1259157 1899221 2531285 317 349 3811413 445 477 509 0 1 1 1 1 30 62 94 126 158 1909 222 2541286 318 1350 3821414 4469 478 510 111111111 31 63 95 127 159 191223 255 287 3191351 383415 447 9 479 511 Table 2 DIP switch address settings yee AN y 111811 n 111181 y NN M OMAN z BEEE 012345678910 012345678910 CEP CET Channel 2 Channel 14 Channel 46 Address Setting Examples 18 Cyclo 04 DMX user manual PES ELE 1 612345678910 Channel 100
8. cause the program will reset to the first scene when the master starts its program from the beginning Here is an example of what will happen when a slave fixture has fewer scenes than the master fixture Scene pattern Master with 7 scenes 01234560123456012 Slave with 3 scenes 01201200120120012 PROGRAM EXAMPLES In all programs in these examples each scene lasts for 1 second at full speed The following symbols are used in program diagrams Fade in V Fade out Tube turned fully off Tube turned fully on Tube turned on at min level Fade to 50 and back to 100 in one scene Example 1 DIP switch 7 is set to OFF crossfade 2096 and only white is selected White AWWM Scene 010101010101 Example 2 DIP switch 7 is set to OFF crossfade 0 and white and red is selected White A A A A A A Red LN A A A A A Scene 012301230123012301230123 Example 3 DIP switch 7 is set to ON crossfade 50 and only white is selected Scene 0000000000000000 Example 4 DIP switch 7 is set to ON crossfade 50 and white and red is selected White AAAMAAAMAAAAAAMAAAAA red WWWNNWNMNMNN Scene 012301230123012301230123012301230123 Example 5 The rainbow effect is achieved by selecting red green blue and DIP switch 7 is set to ON crossfade 50 red A A A A At A A AtA green A A A A A A A A A blue A A A A A A A A Scene 012012012012012012012012012 DMX OPERATION
9. ctionality to be used with a range of other Martin products To have a single fixture run alone it must be set to master Slave fixtures must not be connected to more than one master Advanced master slave To make more advanced schemes it is important to understand how scenes are numbered The scene pattern is always established in the sequence white to red to green to blue This means that if white is enabled it will always be placed first in the program When crossfade 0 is selected each color takes up two scenes fade in and fade out When crossfade 50 is selected each color takes up one scene fade in only Scene numbering always starts at 0 and a maximum number of 8 scenes 0 7 can be set with all colors enabled and crossfade 0 Each scene can be seen as a translation from one output to another this translation is called a fade and the time of the fade is set by the speed setting of the DIP switch When a fixture is in slave mode each new fade is initiated by a synchronization signal received from the master When the slave receives a synchronization signal and initiates a fade it will not act on new synchronization pulses until the fade is complete If a slave fixture has Fewer scenes than the master fixture it will run these in a cycle continuously until the master fixture signals that the program should start from the beginning again More scenes than the master then the additional scenes will never run be
10. e fixture To ensure adequate ventilation we recommend that the Cyclo 04 DMX be installed with a minimum of 25 mm 1 inch of free space on each side Screw the fixture into place using either Reattach the fixture to the mounting plate and lock it into place by tightening the two Phillips screws on the side of the mounting plate AC POWER Maximum power usage data for the Cyclo 04 DMX is supplied in Specifications Cyclo DMX on page 21 Cyclo 04 DMX fixtures incorporate four electronic ballasts that leak a total of between 0 8 4mA of power Because of this we recommend connecting a maximum of seven Cyclo 04 DMX fixtures per phase on a 30mA HPFI circuit breaker A normal 30 mA HPFI circuit breaker normally trips because of a current fault or leakage of approximately 20mA It is important that the installation is carried out correctly in order to avoid unintentional tripping of the circuit breaker Many installations use common neutral leads in branch circuit distribution boxes It is important that the neutral lead in the cable is connected to the same HPFI circuit breaker that it is not connected to the neutral leads from other HPFI circuit breakers The neutral lead must be only associated with that specific circuit breaker Additionally it is important that the fixtures are connected correctly to the ground earth to ensure that the power leakage is able to run off You can power Cyclo 04 DMX fixtures by wiring them
11. e Cyclo 04 DMX is a DMX controllable fluorescent color changer This fixtures is designed to be used for cove lighting perimeter lighting light walls behind semi transparent materials or any place where room is restricted Cyclo 04 DMX is a fixture based on dimmable fluorescent T5 tubes The T5 tubes have achieved widespread popularity due to their design and high efficacy combined with their long lamp life Cyclo 04 DMX control and power cables are through wired for easy installation The Cyclo 04 DMX offers Controllable RGB color mixing Full 0 100 intensity control of the red green blue and white tubes Bright output Long lamp life of 20 000 hours It is important to read this manual through before you attempt to install this product SAFETY INFORMATION This product is for professional use only It is not for household use These products present risks of lethal or severe injury due to fire and heat electric shock and falls Read this manual before powering or installing these fixtures follow the safety precautions listed below and observe all warnings in this manual and on the fixtures If you have questions about how to operate these fixtures safely please contact your Martin dealer or call the Martin 24 hour service hotline at 45 70 200 201 Protection from electric shock Disconnect the fixtures from AC power before removing or installing a lamp fuses or any part and when not in use Always ground eart
12. emale termination plug P N 91613018 into the IN socket of the first fixture FLUORESCENT TUBES Burning in new tubes In order to obtain the full 20000 hour life time new fluorescent tubes must be burned in for 100 hundred hours at full power Identifying tube positions Tube positions are identified in the Cyclo 04 DMX as follows Marking in fixture Marking on tube Color Reference illustration R OSRAM 28 60 Red G OSRAM 28 66 Green S B OSRAM 28 67 Blue R ees OSRAM 28 827 2700K white SS OSRAM 28 840 4000K white None OSRAM 28 860 6000K white CLEANING We recommend that you clean the dust cover with a damp cloth STAND ALONE OPERATION In stand alone mode individual Cyclo 04 DMX fixtures can run a set of pre programmed shows without an external controller Multiple Cyclo 04 DMX fixtures can also be linked together and scene changes on all fixtures can be synchronously triggered by a master fixture SET THE FIXTURE TO STAND ALONE OPERATION Stand alone operation is enabled by setting pin 10 on the DIP switch to ON The DIP switch can be accessed by loosing the cover access screw do not remove it completely and sliding open the access plate as shown in the following illustration DIP SWITCH SETTINGS IN STAND ALONE MODE Pin Function 1 White 2 Red 3 Green 4 Blue 5 amp 6 Program speed Pin6 Pin 5 Speed Off Off Full speed 1 sec pr state Off On 1 5 speed
13. h the fixtures electrically Cyclo 04 DMX user manual Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault protection Do not expose the fixtures to rain or moisture Refer all service to a Martin service technician Protection from burns and fire Provide a minimum clearance of 0 1 meters 4 inches around the fixture Do not modify the fixture or install other than genuine Martin parts Do not operate the fixture if the ambient temperature Ta exceeds 40 C 104 E Protection from injury due to falls Verify that all external covers and rigging hardware are securely fastened Block access below the work area whenever installing or removing the fixture Cyclo 04 DMX user manual INSTALLATION This section describes in general terms how to install the fixture and connect it to AC and dimmer power These procedures shall be performed by qualified professionals p m Mains U d 200 250V AC i 50 60 Hz LI U U U Category 5 DMX network DMX control device To mount the fixture 1 Loosen the two Philips screws holding the mounting plate to the fixture 2 Remove the mounting plate from the fixture 6 Cyclo 04 DMX user manual Warning 3 Fasten the mounting plate to the mounting surface using four 4 mm 1 6th in mounting hardware that is able to bear the 6 7 kg 14 8 lbs weight of th
14. martinarchitectural Cyclo 04 DMX Martin Measurements are in millimeters 2003 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means with out permission in writing from Martin Professional A S Denmark Printed in Denmark P N 35000131 RevA INTRODUCTION 22 ee eke es ss EE EE ER EE Ek EE Ek Ee RR ee 4 Safety information Ee EE EE EE EE nh 4 INSTALLATION oo a a RC 4 Cs 6 Ges MERE in Daca AR ue Ei c ER ENA 7 Data linking multiple fixtures s e e ee eee 8 Fluorescent tubes EE EE eee 10 oe grate rana pav e geb Tae salad dae RT 10 STAND ALONE OPERATION lt lt lt e cece eee eee ees 11 Set the fixture to stand alone operaion 00 ee de ee 11 DIP switch settings in stand alone mode eee eee 12 Program selection e eee 12 Master slave xs ies oe eee O ens Od WE ERO Lee 4 12 Program examples e e SE ete 14 DMX OPERATION 3 2 a uices ca docu ee ene aw eae aaa eae ata 16 Connecting a DMX control device 0 0 0 cee 16 Setting the fixture to DMX operation EE ee Ee ee eee 16 Control address selection llle 17 IOS GGG E EET Nar NTE leq esa aaah eed ee Saeed ae 19 DMX PROTOCOL cia a di aj 20 SPECIFICATIONS CYCLO DMX x x x ee esse ee eee ooo 21 Cyclo 04 DMX user manual INTRODUCTION Note Warning Thank you for selecting the Martin Cyclo 04 DMX Th
15. nnels when setting the control address If control channels for one fixture overlap control channels for another fixture then one of the fixtures will receive the wrong commands Two Cyclo 04 DMXs may share the same address if they are to respond identically They will receive the same commands and individual control will be impossible The default factory set control address is 1 Setting the DMX address 1 Select an address for the fixture on your controller Look up the DIP switch setting for the address in the following table 2 Set pins 1 through 9 ON 1 or OFF 0 as listed in the table 3 Ensure that pin 10 is set to OFF Cyclo 04 DMX user manual 17 Find the address in the table Read the settings for pins 1 5 to the left and read the settings for pins 6 9 above the address O means OFF and 1 means ON Pin 10 is always OFF for DMX operation DIP switch Setting 89 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 880 0 0 0p1 1 1 1 0 0 0 0 1 1 1 1 0 OFF i8 0 0 1 1 0 0p1 1 0 0 1 1 0 0 1 1 17 ON s po 1pop1fo 1pfo 1fo p1po 1fo 1 fo 1 1 2 3 4 5 0 0 0 0 0 32 64 96 128 160 192 224 256 288320 352 384 416 448 480 1 0 0 0 0 1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481 0 1 0 01 0 2 34 66 98 130 1629 194 2261258 2901322 354386 4189 450 48
16. nous way using the stand alone functionality Controlling more than one fixture via a DMX control device Cyclo 04 DMX user manual Creating a data link The data transmission rate 250 kbits s used by DMX512 requires the selection of a cable which does not significantly distort the signal or give rise to spurious signal reflections Cables intended for use with audio systems microphone cables while having the convenience of flexibility availability and relative low cost are NOT suitable for use with DMX512 because of their high capacitance and incorrect characteristic impedance at DMX512 data rates this will give rise to bit time distortion and signal reflections overshoot Cabling systems shall provide a balanced nominal 120 ohm terminated transmission line and be made of cables with a characteristic impedance in the range 100 120 ohms The following cabling accesories can be ordered from your Martin dealer CATS network cables 2 m 6 5 ft x 50 pieces ooooooooooommmo o P N 91611044 CATS network cables 5 m 16 4 ft x 30 pieces uunnunuue c P N 91611045 CATS network cables 10 m 32 8 ft x 15 pieces EE 2 000005 P N 91611045 Termination Plig RIAS sis Stet os nec re RiGee rada P N 91613028 Note Mixing cables of different impedances and other characteristics not isolated by buffers or other processing devices may affect system reliability Always use solid or stranded shielded twi
17. nstallation System connector plug not supplied THERMAL Maximum ambient temperature Ta o oo anuara 40 C 104 F Cooling oie eres an aseo a I Eget Road Edad RA o convection DYNAMIC EFFECTS Dimmable tubes oti divas ob oe beat edad e EN A aces Red green blue and white Independent dimming of each tube via DMX control device CONTROL AND PROGRAMMING Control options eses 0 eee eee eens DMX512 stand alone master slave REC A a DR qug abre RU os ative oes RS 485 Setting and addressing Lg EE R SR oR Z R TE AT Ge TR TRR ARR K 3 DIP switch Data input veins rotatorio ada RJ 45 Data output Es AE AA AA AAA NE RTE ee ae e d RJ 45 DMX CHAN ELS daret SE AI D RIA DS IE AE S UR et E 4 ORDERING INFORMATION Cyclo04 DMX ti SA Bethe aria DEN P N 90550005 Cyclo 04 DMX user manual 21 22 INCLUDED ITEMS sain py an 341 ss AD CN ER ONE Sia noe dine OSRAM T5 FH28W 60 red BE ere rti retten in nne sone pe ROS OSRAM T5 FH 28W 66 green EER EE E Sees OSRAM T5 FH28W 67 blue Lamisil AE TA 59 OSRAM T5 FH28W 840 white User manual ACCESSORIES Diffuser front for Cyclo 04 EE SE ES ee ee ee dee P N 91611078 Termination Plug RJ 45 Te NR RE R Ar aS NT SS Na Se ee ee ee ee ee P N 91613028 ENSTO 3 pole 16A 250V male connector ee ee see See ees ee de P N 05347202 ENSTO 3 pole 16A 250V female connector esse dee see ee dee P N 05327202 RJ 45 connector 15 cm 5 9 in P N 11840088 ENSTO Male female cable
18. sted pair foiled twisted pair STP FTP 100 or 120 ohm cables that conform to ISO IEC 11801 category 5 or higher with RJ 45 connectors wired as follows Pair Wire Color Function DMX512 Pin Pair 2 1 white orange data 1 DMX512 Pin 3 2 orange data 1 DMX512 Pin 2 Pair 3 3 white green data 2 DMX512 Pin 5 4 green data 2 DMX512 Pin 4 Pair 1 5 blue Not assigned 6 white blue Not assigned Pair 4 7 white brown Signal Common 0 v DMX512 Pin 1 8 brown Signal Common 0 v DMX512 Pin 1 Shield drain The minimum wire size is 0 2 mm 24 AWG for runs up to 300 meters 1000 ft and 0 322 mm 26 AWG for runs up 500 meters 1640 ft Your Martin dealer can supply the right cable in various lengths The RJ 45 sockets in the Cyclo 04 DMX are wired as follows pins 7 amp 8 to ground pin 2 to signal cold and pin 1 to signal hot Cyclo 04 DMX user manual 9 Creating the data link Connect the RJ 45 connector on the Cyclo 04 DMX to the RJ 45 connector on the next Cyclo 04 DMX Continue connecting fixtures output to input Up to 32 devices may be connected on a serial link Terminate the link by inserting a an RJ 45 termination plug into the RJ 45 data output of the last fixture Warning If you are using Stand Alone programs see Stand alone operation on page 11 on multiple fixtures on a data link and you experience random flicker or other unexplained control problems insert a f