Home
Pepper Controller
Contents
1. c o i c X l c security systems PTY Ltd Pepper Controller User Manual A Operating across a vast range of industries we use our expertise and insights to respond to client needs in sustainable and innovative ways As such we bring our philosophy of sustainable solutions through partnership to life by remaining committed to finding new and innovative ways to address the challenges of today and tomorrow At Ataraxia we consistently strive to exceed your expectations delivering technology with advanced cutting edge solutions no matter the scale or scope of your PROBLEM We pride ourselves on our ability to provide and deliver the highest level of support The Ultimate goal Peace of Mind System Overview About the Ataraxia Pepper Spray Unit Thank you for purchasing the Ataraxia Pepper spray alarm system You have made a wise decision in choosing it for It uses the latest in microcontroller technology and is specifically designed as a pepper spray alarm controller and SMS notification system The pepper spray alarm controller has been designed to provide the easiest configuration and the best possible convenience to the user for setting up the controller Please read this manual carefully before attempting to interface to the controller Monitoring This system is capable of transmitting alarms troubles and emergency information over GSM networks via SMS messages to specified users If you inadvertently init
2. Master Name Master Dwell Time in Seconds Slave Name slave Spray Time in Seconds Siren Sound Bomb on Time s Current Level in Seconds Zone Contig Slave Canister PIR A on Master Enabled C PIR B on Master Enabled Dwell Time in Seconds E PIR A on Slave Enabled poth onto C PIR B on Slave Enabled Trigger alarm Spray Time in Seconds Maximum Volume in Seconds Current Level in Seconds Prepaid SIM used Cellmodem Enabled Modbus Interface Auxilary Input 1 Disabled Additional IO Auxilarylnput2 Disabled C Enable Control Centre Uplink Control Cente Number 27833069073 A Editing Remotes A AX Ataraxia Configurator Remotel Remote Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Ataraxia Pepper Controller User Manual Name Code Button Button Code Ssynccounter Enabled Remotel 10000150 1022 3 4 0 peace of mind Editing Notifiers AX Ataraxia Configurator Cellphone Notifiers SMS Notifiers Deon Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Not Assigned Country South Africa 27 p Service Provider MTN 01 A Ataraxia Pepper Controller User Manual Notifier 5ettings Deon 27 Enabled E SMS on Po
3. OS Caution The battery terminals may not be reversed or wired improperly Doing this will cause irreversible damage to the controller as well as the connected sensors Connecting the PIR or other sensors For each of the two zones on the controller there are two connections for connecting sensors For Zone 1 they are named ZO1 P1A and Zo1 P1B For Zone 2 it is named ZO2 P1A and Zo2 P1B The 12V terminal and Gnd terminal next to the zone input terminals is to provide power to the sensors which may reguire power i e PIR sensors The zone input is active when the P1A and or P1B terminal is not linked to ground Normally closed PIA and PIB can be disabled enabled via the configuration software The image below shows how the sensors should be connected A Standard Connections of two PIR s connected to Zone 1 A and B Using more than one PIR on a Zone input If you want to connect more than one PIR on a Zone input do the connection as detailed below Please note that the system is wired in a closed loop If more than one sensor is wired to a single zone input the sensors MUST be wired in series configuration A Ataraxia Pepper Controller User Manual peace of mind Connecting external LED s to display the status You can display the status on external LED s wired to the outside of a building or structure to display the status of the alarm controller before you attempt to enter the building The termina
4. ames of the terminals as well as the meaning of each terminal and the use for it ADD ADD MOD MOD MOD EXT EXT EXT 202 202 202 Z02 Z01 201 201 ZO1 ALM ALM SIR SIR CAN2 CAN2 CAN1 CAN1 BAT BAT AC AC IN1 GND GND RX TX JSAFEIARM 12V GND 12V PIB PA GND 12V PIB PIA NO COM POS NEG POS NEG POS NEG POS NEG SOL SOL Power Supply If you are powering from an AC Transformer 16 24Vac 1 5A Min use the two terminals marked AC on the far right hand side of the unit CAUTION The battery terminals may not be reversed or wired improperly Doing this will cause irreversible damage to the controlled as well as the connected sensors 16 gt 24VAC A Ataraxia Pepper Controller User Manual peace of mind Powering from Solar Panel If you are powering the unit from a solar panel use the two terminals marked AC SOL on the far right hand side of the unit Positive and negative wires from the solar panel do not need to be in specific terminal order Caution The battery terminals may not be reversed or wired improperly Doing this will cause irreversible damage to the controller as well as the connected sensors Connecting the Battery Connect the Positive side of the battery to the Red battery lead or directly to the terminal marked BAT POS Connect the Negative side of the battery to the black battery lead or directly to the terminal marked BAT P
5. d Data From Unit Selected Port COM3 Read Complete Please ensure that your computer Laptop have a serial port or have a USB serial device connected prior to starting this software All available ports on your computer Laptop will be displayed in the top left box Select the port that is connected to the Ataraxia device and click on Read Data From Unit After a successful connection the offline signal at the top right will change to Online Use the NEXT Button to Navigate through the software or click on the tabs to FReset navigate to a specific item I Com patibility Mode for Previous Versions Main Board Version Ver 1 Rev 25 Release Date 7013 08 040 Main Board Serial No 1308010069 Start the Application by clicking on the Ataraxia Configurator Icon located on your desktop or start menu Click on the Next button to navigate to the Communications TAB To communicate with the unit you need a RS 232 port on your Computer Laptop You will also require the configuration programming cable Select the port connected to the Main Controller Click the Read Data From unit Button Follow the progress bar and wait for the Read Complete message to appear A Ataraxia Pepper Controller User Manual peace of mind Editing Global Settings AX Ataraxia Configurator Start Communications Global Settings Global Settings Master Canister Unit Name New Ataraxia Unit Maximum Volume in Seconds
6. ent the internal buzzer will beep three times Arming the system When the remote is pressed and siren sounds once the system is armed If the external status LED is used it will light up to indicate that the system is armed Please do not enter the site after the system is armed as it will result in the pepper gas being released and SMS notifications to be sent to all configured users Disarming the system When the remote is pressed and siren sounds twice the system is disarmed If the external status LED is used the light will go out to indicate that the system is disarmed You can now enter the site as the Pepper gas release system is disabled If configured the controlled will send SMS s to users indicating that the system was disarmed Intrusion Alarm If an intrusion alarm sounds indicated by a continuous bell or siren configurable time period the alarm may be silenced by pressing the remote supplied with the unit This will disarm the unit Please note that the pepper gas would have been released in the site and caution must be taken before entering the site NOTE If you return and find that an alarm has occurred while you were away it is possible thatan intruder may still be on the premises AN Unit Wiring ataraxia peace of mind A an a am mx run En pun wen ron wen pn mx fama 15r eman 12 mui rw eman umr ui run wm cnu Jon oe Terminals Please see below the n
7. for each unit repaired Products which Quantum Design and Engineering PTY Ltd determines not to be repairable will be replaced by the nearest equivalent product available at that time The current market price of the replacement product will be charged for each replacement unit WARNING Quantum Design and Engineering PTY Ltd recommends that the entire system be completely tested on a regular basis However despite frequent testing and due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to perform as expected AN
8. hat for a period of twelve months from the date of purchase the product shall be free of defects in materials and workmanship under normal use During the warranty period Quantum Design and Engineering PTY Ltd shall at its option repair or replace any defective product upon return of the product to its factory at no charge for labour and materials Any replacement and or repaired parts are warranted for the remainder of the original warranty or ninety 90 days whichever is longer The original owner must promptly notify Ouantum Design and Engineering PTY Ltd in writing that there is defect in mater al or workmanship such written notice to be received in all events prior to expiration of the warranty period International Warranty The warranty for international customers is the same as for any customer within South Africa with the exception that Ouantum Design and Engineering PTY Ltd shall not be responsible for any customs fees taxes or VAT that may be due Warranty Procedure To obtain service under this warranty please return the item s in guestion to the point of purchase All authorized distributors and dealers have a warranty program Anyone returning goods to Ouantum Design and Engineering PTY Ltd must first obtain an authorization number Ouantum Design and Engineering PTY Ltd will not accept any shipment whatsoever for which prior authorization has not been obtained Conditions to Void Warranty This warranty applies o
9. iate an alarm immediately notify the central station to prevent an unnecessary response NOTE The SMS notification function must be enabled by the installer before it becomes functional Features Canister Level Monitoring Resettable with pushbutton Support for External Status LED s External Alarm Output Relay Closed contact on Alarm Supports control for 2 Pepper Canisters Individual Zones 128 bit Encrypted Remotes with Unigue User Id for Armed and Disarmed State Adjustable Siren Time Adjustable pepper spray release time and dwell time SMS Notifications on selectable alarm fault states General System Operation Your Pepper spray alarm system is made up of a QDE ATX MP1 Controller one or more PIR s a 7Amp hr 13 5 Volt Battery 12Volt Actuator Siren 16Vac 1 25 A power transformer and a Ataraxia pepper gas canister One or more remotes is supplied with the system that is specifically code locked to the Ataraxia Units the main controller have an audible indicator for specific events and LED s to indicate specific statuses A Remotes Remotes are used to arm and disarm the system Up to 15 Remotes can be programmed into each controlled via the supplied configuration software A username can be tagged to each remote for customised SMS messages when a system is armed or disarmed Please note that a system cannot be armed whilst the sensors detect movement When a user tries to arm a unit while the sensor s detects movem
10. ing device evade detection by moving through an area of insuff icient coverage disconnect a warning device or interfere with or prevent the proper operation of the system Criminal Knowledge This system contains security features which were known to be effective at the time of manufacture It is possible for persons with criminal intent to develop technigues which reduce the effectiveness of these features It is important that a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected A Inadeguate Installation A security system must be installed properly in order to provide adequate protection Every installation should be evaluated by a security professional to ensure that all access points and areas are covered Locks and latches on windows and doors must be secure and operate as intended Windows doors walls ceilings and other building materials must be of sufficient strength and construction to provide the level of protection expected A re evaluation must be done during and after any construction activity Failure of Replaceable Batteries This system s wireless transmitters have been designed to provide several years of battery life under normal conditions The expected battery life is a function of the device environment usage and type Ambient conditions such as high humidity high or low temperatures or
11. large temperature fluctuations may reduce the expected battery life While each transmitting device has a low battery monitor which identifies when the batteries need to be replaced this monitor may fail to operate as expected Regular testing and maintenance will keep the system in good operating condition Insufficient Time There may be circumstances when the system will operate as intended yet the occupants will not be protected from the emergency due to their inability to respond to the warnings in a timely manner If the system is monitored the response may not occur in time to protect the occupants or their belongings Component Failure Although every effort has been made to make this system as reliable as possible the system may fail to function as intended due to the failure of a component Inadeguate Testing Most problems that would prevent an alarm system from operating as intended can be found by regular testing and maintenance The complete system should be tested weekly and immediately after a break in an attempted break in a fire a storm an earthguake an accident or any kind of construction activity inside or outside the premises The testing should include all sensing devices alarm indicating devices and any other operational devices that are part of the system AN Appendix A Supported Modbus Address Registers AN LIMITED WARRANTY Ouantum Design and Engineering PTY Ltd warrants the original purchaser t
12. ls marked as per the image below can be used for this purpose The EXT 12V power source is a protected power source specifically for the Arm and Safe LEDs and cannot be used to power any other device AN Ataraxia Pepper Controller User Manual peace of mind LED indicators The main controller has 4 Tri Colour LED s to display specific statuses and information Power LED When the Power LED is Green it means that the controller is connected to external power i e AC Transformer or solar panel When is is red it means that the External supply is lost or removed If configured the Power Off status will send a SMS notification to configured users Status LED The status LED displays the current state of the controller If Red it is armed and ready to release gas in the event of an intrusion If the light is green the controlled is disarmed and it is safe to enter the monitored site External LED s can also be wired to show the Status Canister LED When the inserted Pepper Gas canisters is full the Canister LED will glow bright green As the gas gets released the light will go dimmer When only 50 volume of the canister is left the LED will turn yellow and progress to bright red as the pepper gas volume drops A Software Installing the Configuration Software ToDO Using the Configuration Software N Ataraxia Configurator Click on a Port and then click on the READ button Rea
13. nly to defects in parts and workmanship relating to normal use It does not cover damage incurred in shipping or handling damage caused by disaster such as fire flood wind earthquake or lightning damage due to causes beyond the control of Quantum Design and Engineering PTY Ltd such as excessive voltage mechanical shock or water damage damage caused by unauthorized attachment alterations modifications or foreign objects damage caused by peripherals unless such peripherals were supplied by Quantum Design and Engineering PTY Ltd defects caused by failure to provide a suitable installation environment for the products damage caused by use of the products for purposes other than those for which it was designed damage from improper maintenance damage arising out of any other abuse mishandling or improper application of the products Ouantum Design and Engineering PTY Ltd s liability for failure to repair the product under this warranty after a reasonable number of attempts will be limited to a replacement of the product as the exclusive remedy for breach of warranty Under no circumstances shall Ouantum Design and Engineering PTY Ltd be liable for any special incidental or consequential damages based upon breach of warranty breach of contract negligence strict liability or any other legal theory Such damages include but are not limited to loss of profits loss of the product or any associated equipme
14. nt cost of capital cost of substitute or replacement equipment facilities or services down time purchaser s time the claims of third parties including customers and injury to property Disclaimer of Warranties This warranty contains the entire warranty and shall be in lieu of any and all other warranties whether expressed or implied including all implied warranties of merchantability or fitness for a particular purpose And of all other obligations or liabilities on the part of Quantum Design and Engineering PTY Ltd Quantum Design and Engineering PTY Ltd neither assumes nor authorizes any other person purporting to act on its behalf to modify or to change this warranty nor to assume for it any other warranty or liability concerning this product Out of Warranty Repairs Quantum Design and Engineering PTY Ltd will at its option repair or replace out of warranty products which are returned to its factory according to the following conditions Anyone returning goods to Quantum Design and Engineering PTY Ltd must first obtain an authorization number Quantum Design and Engineering PTY Ltd will not accept any shipment whatsoever for which prior authorization has not been obtained Products which Quantum Design and Engineering PTY Ltd determines to be repairable will be repaired and returned A set fee which Quantum Design and Engineering PTY Ltd has predetermined and which may be revised from time to time will be charged
15. re burglary or other types of emergencies where it may not provide protection Any alarm system of any type may be compromised deliberately or may fail to operate as expected for a variety of reasons Some but not all of these reasons may be Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discriminate between intruders and intended occupants Motion detectors do not provide volumetric area protection They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams They cannot detect motion which occurs behind walls ceilings floor closed doors glass partitions glass doors or windows Any type of tampering whether intentional or unintentional such as masking painting or spraying of any material on the lenses mirrors windows or any other part of the detection system will impair its proper operation Passive infrared motion detectors operate by sensing changes in temperature However their effectiveness can be reduced when the ambient temperature rises near or above body temperature or if there are intentional or unintentional sources of heat in or near the detection area Some of these heat sources could be heaters radiators stoves barbegues fireplaces sunlight steam vents lighting and so on Access by Intruders Intruders may enter through an unprotected access point circumvent a sens
16. wer UP Restart SMS on Mains Fail SM5 on Battery Low SMS on System Arm C SMS on System Disarm SMS on Alarm Master SMS on Low Canister C SMS on Auxilary Input 1 E SMS on Auxilary Input 2 E SMS Low Airtime Alarm E Allow SMS Control E Future 12 E Future 13 E Future 14 E Future 15 peace of mind Downloading the Configuration AX Ataraxia Configurator Program the Unit Test the Unit Send a Test SMS Cell No 27 Send SM5 Message 80 Chars Max This is a test 5M5 Get Cellmodem Status EF A Add on Modules GSM Cell Modem Interface ToDo RS232 Modbus Interface Currently the module only supports function 16 Modbus commands Holding Registers These registers however is all that is required to get all the information from the Ataraxia Controller AN Ataraxia Pepper Controller User Manual peace of mind Troubleshooting Viewing Trouble Conditions The control panel continuously monitors a number of possible trouble conditions If one of these trouble conditions occur it will be displayed on the LED s or if configured and SMS s will be sent to specific users NOTE A TROUBLE condition reduces the security your system is designed to provide Call your installing company for service Maintenance Notes to installers System Failures This system has been carefully designed to be as effective as possible There are circumstances however involving fi
Download Pdf Manuals
Related Search
Related Contents
E-P132-100 User Manual - KSH Internation Co., Ltd. Magazine n°27 - Brie Nangissienne 4,53Mo - Kawa 900Z Montage- und Betriebsanleitung 3 GB Installation DieselPro User Manual User Manual Mikrotik CCR1009-8G-1S-1S+ Ethernet LAN router プロジェクター利用の手引き (PDF 111kb) Copyright © All rights reserved.
Failed to retrieve file