Home

Pre-Delivery Orientation (PDO)

image

Contents

1. Exhaust fans kitchen bathrooms if provided Electrical outlets and fixtures Flooring hardwood vinyl ceramic tiles carpeting Gas fireplaces incl circulation fans if provided Interior finishes and trim carpentry Furnace Heat Recovery Ventilation system if provided Heating system Hot water heater if provided not a rental Hot water heater if provided not a rental Exterior finishes driveways walkways decks and Air conditioning system if provided and if landscaping are complete conditions permit TARN PDIF 01 01 PDF Unit Enrolment 1 will remove the sticker from the CCP and place it inside the breaker panel in your suite This ensures that the enrolment and reference numbers are readily available to you for future reference SPRING MINTOGARDENS MASTERCARE PDO 45 During your PDO your MasterCare Rep will place your Certificate of Completion and Possession number inside the breaker panel in your suite Suite Entrance Door 46 Suite Entrance Door Deadbolt Lock Intrusion Alarm Panel All Off Switch Main Communications Box Your PDO Companion Getting To Know Your New Home The following checklist has been designed to help acquaint you with your new condominium home During your Pre Delivery Orientation PDO a Minto MasterCare Representative will review workmanship and finishes in your suite with you as well adv
2. Manual as well as master code numbers for your suite intrusion alarm system will be included in the key package you will receive on your date of possession The All Off switch identified with a distinctive green switch located on the wall beside the suite entrance door is not only handy and helpful but is also a practical feature that allows you to conserve energy by activating the Energy Savings Mode on the thermostat and shutting off power to all hard wired lighting in your suite simply by turning off a single switch This grey metal box typically located on the ceiling inside the foyer closet is the central hub for all telecommunications services within your suite as well as the entry point for low voltage services entering the suite telephone data TV intrusion alarm water metering SPRING MINTOGARDENS MASTERCARE PDO KITCHEN Energy Star Refrigerator Above Range Exhaust Fan Energy Star Range Energy Star Dishwasher Appliance Warranty Packages Appliance Service Kitchen Sink amp Dishwasher Shut Off Valves GFCI Protected Electrical Outlet Check the fridge to ensure it is connected and working as intended the fridge is cooling and the light turns on when the door is opened Fan is incorporated into your microwave unit and is ducted to the exterior of the building The on off switch for the exhaust fan is located on the microwave control panel Switch both the fan and light on and off to ensure th
3. Shut Off Valves Cold amp Hot Exhaust Fan s Low Volume Dual Flush Toilets The MasterCare Representative will identify the locations for you Bathroom electrical outlets are GFCI protected preventing the risk of electrical shock If a GFCI outlet trips in order to provide protection it has to be reset using the associated RESET button to restore power to it The MasterCare Representative will identify the Test and Reset buttons for you on the electrical outlet cover You should test the GFCI receptacles as part of your regular homeowner s maintenance program Check to ensure that cold and hot water come out of both the sink and bathtub faucets Test them to ensure they work and hold water when in the CLOSED position The sink shut off valves are located inside the vanity cabinet below the bathroom sink Should an emergency such as a leak or flood occur the shut off valves allow you to turn off the water to the sink There is a shut off valve that enables you to turn off the water to the toilet only This valve is located on the wall next to below the toilet tank These valves installed upstream of the cold and hot water meters generally located in the main bathroom inside the vanity cabinet below the sink make it possible to shut off the water supply to the entire suite In suites with more than one bathroom the main water shut off valve is typically located in the master bathroom Each bathroom has an exhau
4. for increased energy savings when you are away from the suite The thermostat is set automatically into Energy Savings Mode by activating the All Off switch The MasterCare Representative will review the thermostat and its operation with you All suites are heated and cooled by means of a Fan Coil Heat Recovery Ventilation System HRV Larger suites have two or more Fan Coil units If your suite has more than one only one is an HRV The unit is located behind a rectangular metal cover panel that is typically located on the living room and or bedroom wall The filter for the unit is located behind the cover panel The MasterCare Representative will verify its presence during the PDO Like the living room a wall switch controls one half of a duplex electrical outlet in the bedroom s Power will only be directed to that portion of the electrical outlet when the corresponding light switch is in the ON position Check all electrical outlets to ensure both top and bottom sockets have power Typically the breaker panel is located on the wall in the corridor to the bedrooms or on the wall behind the master bedroom door The MasterCare Representative will identify the breaker panel for you The breaker panel in your suite contains circuit breakers and each circuit breaker is labelled to indicate the area or device it controls When an electrical circuit becomes overloaded the breaker opens breaks the circuit and the correspondin
5. Pre Delivery Orientation PDO The industry standard name for this meeting is Pre Delivery Inspection or PDI With Minto this appointment is more than just an inspection The Pre Delivery At your PDO we will review Orientation PDO is your first real opportunity to experience your new home in suite systems and explain how they operate We will review in suite finishes and workmanship with you and record any concerns We also walk you through your suite features and systems and explain how they operate Any deficiencies you record at PDO will be noted and attended to prior to your possession date Some repairs may take a little longer if material is required Here are some frequently asked questions about the Pre Delivery Orientation Who should attend a Pre Delivery Orientation The Pre Delivery Orientation is a time to learn about and familiarize yourself with your new home We therefore recommend that only the principal homeowners attend We also recommend that you limit the number of people who come to the PDO because it is a working session Based on the length of the visit we discourage bringing small children What if I am not able to attend the PDO The PDO is pre requisite to closing the suite and must be conducted prior to your closing date If you are not able to attend please let us know and we will send you a designate form You can select a designate to attend the meeting and sign off for you Don t forget to b
6. eaker located on the ceiling in your suite makes it possible for you to receive vital information regarding emergency situations Its primary function is to sound the fire alarm in your suite Therefore when the fire alarm is activated in the building you will hear it in your suite through the EVC Only authorized building personnel or the authorities such as the fire department can use it to 1 inform you of emergencies in the building 2 provide you with instructions as required and 3 update you on the status of an emergency situation The MasterCare Representative will identify the emergency speaker s for you during your PDO The emergency speaker is hard wired wired directly into the building fire alarm system and therefore does not require batteries Heat Detector s The heat detector located on the ceiling in your suite is a safety device that detects heat from potential fire The MasterCare Representative will identify the heat detector during your PDO The heat detector is hard wired directly to the building s fire alarm system which will sound when a heat detector is activated In accordance with the Ontario Fire Code heat detectors are installed in every suite and can never be removed by the homeowner 50 SPRING MINTOGARDENS MASTERCARE PDO Smoke Detector s The smoke detector s located on the ceiling in your suite notifies you of smoke and potential fire within your suite Smoke detectors sound only i
7. ey are both working as intended Please Note You should always use the exhaust fan when cooking on the stovetop to help control odours and humidity within your suite Turn the cook top portion of the range as well as the oven on and off to ensure everything is operating as intended Please Note Make sure all warranty information and or packaging is removed from inside the oven before turning it on Turn the dishwasher on and off to make sure it is hooked up and working as intended Please Note Make sure all warranty information and or packaging is removed from inside the dishwasher before turning it on Instruction manuals for your appliances are stored together in a top drawer in your kitchen We suggest you keep these in your Homeowner Organizer Your new appliances come with a One Year Manufacturer s Warranty As with all other service requests MasterCare will be happy to direct you with any appliance related warranty service requests by making the first call to Appliance Canada on your behalf It is recommended however that you call Appliance Canada directly to report the problem and arrange a service appointment Their contact information will be provided in this Homeowner s Manual Check to ensure that both the cold and hot water come out of the faucet The MasterCare Representative will identify the location of the cold and hot water shut off valves as well as the dishwasher intake shut off valve These are located in the cab
8. g breaker automatically switches off A circuit breaker once tripped must be reset to resume normal operation Should an electrical outlet or fixture in your suite not work check the breaker panel first to see if a circuit breaker has tripped Circuit breakers have three 3 positions ON TRIPPED and OFF To reset a circuit breaker first turn it to OFF completely before you turn it back to ON Switching the breaker directly from TRIPPED to ON will not restore service If the breaker does not reset and power is not restored advise MasterCare by completing a Service Request Form Please Note Always use a licensed professional Electrician if you choose to replace existing light fixtures or install lighting in your suite Please be aware that the wiring in a high rise condominium building differs substantially from that in a single family home Therefore incorrect installation could cause the fixture itself and or other electrical outlets and switches in the suite to malfunction 48 SPRING MINTOGARDENS MASTERCARE PDO TELEPHONE CABLE AND COMPUTER OUTLETS Telephone Cable and Computer Outlets Your suite is wired for telephone data and cable services Outlets for telephone cable and data are installed in your suite BATHROOM S GFCI Ground Fault Circuit Interrupter Outlet s Sink and Bathtub Sink and Bathtub Stoppers Sink Shut Off Valves Toilet Shut Off Valve Main Water
9. inet below the sink Knowing the location of these valves is essential particularly in the event of a plumbing emergency Should you ever experience a leak or a flood in the kitchen turn off the water in the kitchen as soon as possible to help mitigate any damage that could occur as a result of water exposure A Ground Fault Circuit Interrupter is a safety feature on electrical outlets located in the vicinity of a sink or water source that prevents the risk of electrical shock All GFCI receptacles can be tested and re set through an associated Test Reset button SPRING MINTOGARDENS MASTERCARE PDO 47 LIVING ROOM Wall Switch Controlled Electrical Outlet Thermostat HEATING COOLING UNIT S Fan Coil Heat Recovery Ventilation System HRV BEDROOM S Wall Switch Controlled Electrical Outlet Breaker Panel Please Remember It is your responsibility to advise Property Management of any additions and or changes you make to the electrical telephone cable and or data wiring in your suite A switch on the wall controls one half of a duplex electrical outlet in the living room The MasterCare Representative will identify this electrical outlet for you The thermostat offers the single greatest and easiest opportunity to conserve energy requiring nothing more than adjusting a switch to your desired temperature setting It allows you to select the temperature to your comfort level when you are home and adjust
10. ise you of the locations and correct operation of the various systems and equipment within your suite We emphasize the importance of the PDO as an opportunity for you to acquire valuable information regarding your new home as well as inspect your suite therefore it would be beneficial for you to familiarize yourself with this checklist prior to attending your appointment To make the most of your PDO we suggest you bring this PDO Companion with you and check off each of the listed items as you proceed through your appointment Se Green Features The slight gap under your suite entrance door is not a deficiency but is an essential part of the ventilation system as it provides an exchange of fresh air from the corridor to your suite Please Note Weather stripping should never be installed around your suite entrance door since it would impede the exchange of fresh air between the corridor and your suite and thus compromise the ventilation system Test to ensure that it locks and unlocks as intended The intrusion alarm panel is located on the foyer wall in close proximity to the front entrance door of your suite The intrusion alarm system for your suite is connected to a computer system located at the Concierge desk and Property Management office When armed the intrusion alarm system will monitor access through the front entrance door and will alert the Concierge and Property Management team of any unauthorized access A User s
11. l receive at the end of the Orientation The PDI Form serves as the official written record of the condition of your new home before you move in and will be used as a reference for future warranty service requests Certificate of Completion and Possession CCP At the time of your Orientation you will also receive a copy of the Certificate of Completion and Possession CCP which confirms that your new home has been enrolled with the Tarion Warranty Corporation Your home s enrolment number appears in the upper right hand corner as well as on the sticker affixed to the bottom left side of the form During your Pre Delivery Orientation the MasterCare Representative III TARION PROTECTING ONTARIO S NEW HOME BUYERS Pre Delivery Inspection Form Please list below any damaged incomplete or missing items as well as anything that is not operating properly Also note any substitutions of items referred to in or to be selected under the Agreement of Purchase and Sale APS or construction contract Please initial all changes and deletions As a minimum check the following DAMAGED INCOMPLETE OR MISSING OPERATING CONDITION Windows side lights and other glazing Window Windows interior and exterior doors including and door screens Bathtubs sinks and toilets Bathroom accessories if provided Mirrors countertops and cabinetry garage overhead door Door locks Faucets kitchen bathroom laundry room
12. n your suite The MasterCare Representative will identify the smoke detector s during your PDO The smoke detector s is hard wired to your in suite electrical panel and does not require batteries In case of a power failure to the building the smoke detector will not operate Please note The smoke detector s is are rather sensitive and may go off as a result of burnt toast excessive humidity from bathing or cooking or vapours from chemicals in cleaning products Carbon Monoxide A Carbon Monoxide CO Detector combined with a smoke detector is only Detector provided in those suites that are situated in close proximity to gas fired mechanical systems as required by the Ontario Building Code Combination smoke and CO detectors are hard wired to the in suite electrical panel and do not require batteries In case of a power failure to the building the carbon monoxide detector will not operate Please note Your building is equipped with emergency generators to ensure that life safety devices in your suite continue to function as intended should a power failure occur Fire Alarm This button is usually located on the bedroom corridor or living room wall Silencer Button Should the fire alarm go off in the building you could press the fire alarm silencer button and quiet the fire alarm within your suite for up to ten 10 minutes before it begins resounding again If an announcement is made it will still be heard even if you pres
13. ring a The designate should be a close family member or friend that you trust to conduct this camera and tape measure business on your behalf to your PDO What should I wear If your Pre Delivery Orientation is scheduled to take place prior to occupancy you will be required to wear a hard hat and safety boots which Minto will provide For this reason we also ask that you wear long pants Remember to bring along a pair of socks as you will need them inside the safety boots Will I have the opportunity to take measurements prior to my possession date We are able to accommodate one visit between your Pre Delivery Orientation and closing date This will be your opportunity to measure for window coverings and closet organizers or get quotes for work that you will be doing after you take possession You can contact our MasterCare office to arrange this visit at 416 486 4686 or by email at askmastercare mintospring com 44 SPRING MINTOGARDENS MASTERCARE PDO Pre Delivery Inspection PDI Form Prior to your closing date you will complete an in suite inspection as part of your Pre Delivery Orientation with a Minto MasterCare Representative Any defects in workmanship or materials incomplete or missing items that are discovered during your inspection as well as anything that is not operating properly or can not be assessed because it is obscured from view or was inaccessible will be listed on the PDI Form a copy of which you wil
14. sed the silencer button The alarm will still be audible from the corridor but will not be as loud or disruptive At the end of your Pre Delivery Orientation the MasterCare Representative will review and provide you with a copy of the following A copy of the Certificate of Completion and Possession CCP for your suite e This form confirms that your new home has been enrolled with the Tarion Warranty Corporation Your home s enrolment number appears in the upper right hand corner as well as on the sticker affixed to the bottom left side of the form You will be asked to date and sign this form at your Pre Delivery Orientation A copy of the completed PDI Form e This form lists any defects in workmanship or materials incomplete or missing items that you observed during your in suite inspection as well as anything that was not operating properly or could not be assessed because it was obscured from view or was inaccessible You will be asked to date and sign this form at your Pre Delivery Orientation SPRING MINTOGARDENS MASTERCARE PDO 51
15. st fan that is controlled by a wall switch The fan in the main bathroom operates continuously on low speed to provide airflow through the HRV unit The wall switch controls fan operation from low to high speeds only Use the wall switch to ensure the fan operates as intended The fan removes moisture and humidity from the air by directing it to the exterior of the building Therefore in order to control the humidity within the bathroom as well as throughout your suite it is important for you to remember to always use the fan when showering or bathing The Ontario Building Code specifies the use of water saving toilets in all new residential construction The toilet s in your suite uses less water per flush than older models and features a two button activation system that provides you with substantial water savings One button is for liquid waste and one button is for solid waste Flush toilet s to make sure that the water empties from the bowl as intended SPRING MINTOGARDENS MASTERCARE PDO 49 LAUNDRY ROOM Dryer Duct amp There is a duct that connects from the dryer in your suite to the exterior of the Auxiliary Lint Trap condominium building An exhaust fan is automatically activated when the dryer is turned on stays on the entire time the dryer is in use and pushes moist air from the dryer through the duct to the exterior The auxiliary lint trap is located on the ceiling inside your laundry closet The screen in the trap capt
16. ures lint as the moist air travels through it As a homeowner it is your responsibility to check and clean the screen inside the trap on a regular basis Carefully pull down on the knob to open the panel and access and clean the screen The lint trap located inside the dryer itself should be cleaned after every load and the screen inside the auxiliary lint trap on the ceiling should be cleaned frequently Please Note Ensuring that both lint traps are lint free is essential in maintaining the maximum efficiency of your dryer and preventing the risk of a fire Water Shut Off Valve The white box recessed in the wall beside your washer dryer stacked unit for the Washer contains the combined cold and hot water shut off valve for your washer The lever may be pulled forward or pushed back to turn the water supply on or off as required It is recommended that you turn the water supply to the washer off when you re not using it This is a precautionary measure that will help prevent a possible emergency situation from occurring such as a water supply hose bursting LIFESAFETY DEVICES The Emergency Speaker s Heat Detector s and Carbon Monoxide detector in your suite must never be disconnected or tampered with doing so would compromise the life safety of all residents would be in violation of the Ontario Fire Code and would be subject to a substantial fine Emergency Speaker s gt The emergency speaker EVC Emergency Voice Communication sp