1. 6 Marks A D should all be in the same spot If not the unit will need to be recalibrated Please see calibration adjustment information 2015 Johnson Level amp Tool 9 ec 8862H English_Manuals 3 19 15 3 30 P Page 10 Accuracy Self Check Horizontal Laser 40 6693 and 40 6695 only 1 Setthe instrument on a level surface such as a flat head tripod centered between two walls marked 1 amp 2 approximately 25 feet apart See fig 1 2 Point the instrument directly at wall 1 Turn the laser on and mark the beam as point A 3 Turn the instrument 180 degrees so that the laser is pointed directly at wall 2 Turn the laser and mark the beam as point B 4 Move the instrument and the tripod so the laser is positioned approximately 2 feet away from wall 1 see fig 2 Level the tripod and position the instrument on the tripod facing wall 1 Turn the laser on and mark the beam as point C 5 Turn the laser off and rotate the laser 180 degrees so that it is facing directly to wall 2 6 Tum on the laser and mark the beam as point D Wall 1 Wall 2 7 Measure the distance between points A amp C 8 Measure the distance between points B amp D 9 If the difference between points A amp C and points B amp D are less than 1 16 your instrument is within its tolerance 10 If it is greater than 1 16 your unit will need to be recalibrated 10 2015 Johnson Level amp Too 8862H English_Manuals 3 19
2. 2015 Johnson Level amp Tool 7 ec 8862H English_Manuals 3 19 15 3 30 P Page 8 This laser level was designed for various mounting applications 1 Laser base can be attached to a 5 8 x 11 or 1 4 x 20 tripod 2 Laser can be attached to a pole or ladder by using the mounting strap 3 Position the laser by rotating the laser to shoot the beam down the back of the base Ideal for installing x metal track 4 Rare earth magnets located on base allows the base to attach to metal surfaces Wall 5 The laser can be attached to a wall with a Hang nail screw using the wall hang hole Hole 8 2015 Johnson Level amp Tool Din 3 19 15 3 30 P Page 9 8 Self Check amp Fine Calibration IMPORTANT It is the responsibility of the user to verify the calibration of the laser before each use m Figure 1 Accuracy Self Check Plumb point accuracy self check 1 As shown in figure 1 put the unit on the ground in the direction shown in figure 1 1 2 Power on the unit and mark the center of plumb down as point E and plumb up point as A 3 Turn the unit 90 as shown in figure 1 2 and place the down beam on the E mark Mark the center of the plumb up point as B 4 Turn the unit 90 again as shown in figure 1 3 and repeat step 3 Mark the center of the plumb up point as C 5 Turn the unit 90 again as shown in figure 1 4 and repeat step 3 Mark the center of the plumb up point as D
3. 30 P Page 13 10 Application Demonstrations Reference for fence installation Reference for pipeline installation Reference for dormer installation Plumb reference for lamp installation Reference for door frame installation Reference for construction cubic partition Reference for vertical partition 2015 Johnson Level amp Tool 13 ec 8862H English_Manuals 3 19 15 3 30 P Page 14 11 Care and Handling This laser unit is a precision tool that must be handled with care Avoid exposing unit to shock vibrations and extreme temperatures Before moving or transporting the unit make sure that the unit is turned off Remove the batteries when storing the unit for an extended time more than three months to avoid damage to the unit should the batteries deteriorate Always store the unit in its case when not in use Avoid getting the unit wet Keep the laser unit dry and clean especially the laser output window Remove any moisture or dirt with a soft dry cloth Do not use harsh chemicals strong detergents or cleaning solvents to clean the laser unit 12 Product Warranty Johnson Level amp Tool offers a three year limited warranty on each of its products You can obtain a copy of the limited warranty for a Johnson Level amp Tool product by contacting Johnson Level amp Tool s Customer Service Department as provided below or by visiting our web site at www johnsonlevel com The limited warran
4. and On Off Switch 1 4 Screw Thread Hole Calibration Port Plug Output Window Belt Slot Wall Hang Hole Magnets Laser Attachment Wheel 1 4 Screw to Attach Laser Magnets ga and 5 8 Screw to Attach to Tripod 2015 Johnson Level amp Tool ec anis E 3 19 15 3 30 P Page 6 6 Operating Instructions IMPORTANT It is the responsibility of the user to verify the calibration of the laser before each use Alkaline Battery Installation Note Always check to be sure that the on off switch is in the off position before removing and replacing batteries v 1 As shown in figure unscrew the battery cover and put 3 AA alkaline batteries into the battery compartment noting the polarity as shown in the battery compartment Screw the battery cover shut Turn the on off switch to on If the power LED is flashing the battery is low 6 2015 Johnson Level amp Tool ec 8862H English_Manuals 3 19 15 3 30 P Page 7 7 Using the Product Power on off Turn the compensator lock on off switch in the direction indicated by the arrow To unlock and tum laser on To lock and tum laser off Note Product must be within 3 of level for self leveling feature to function properly Greater than 3 will result in an alarm condition flashing laser and intermittent beeping sound Output of laser line 40 6692 40 6693 U 40 6695 Up Up d Left Right Front Front Down an Down Un Down Jus
5. place the laser tool in a manner that may cause someone to unintentionally look into the laser beam Serious eye injury may result Do not operate the tool in explosive environments i e in the presence of gases or flammable liquids Keep the laser tool out of the reach of children and other untrained persons Do not attempt to view the laser beam through optical tools such as telescopes as serious eye injury may result Always turn the laser tool off when not in use or left unattended for a period of time Remove the batteries when storing the tool for an extended time more than 3 months to avoid damage to the tool should the batteries deteriorate Do not attempt to repair or disassemble the laser tool If unqualified persons attempt to repair this tool warranty will be void Use only original Johnson parts and accessories purchased from your Johnson authorized dealer Use of non Johnson parts and accessories will void warranty 2015 Johnson Level amp Tool 3 8862H English_Manuals 3 19 15 3 30 P Page 4 DANGER Class Illa Laser Product Max Power Output lt 5mW Wavelength 625 645nm THIS TOOL EMITS LASER RADIATION DO NOT STARE INTO BEAM AVOID DIRECT EYE EXPOSURE 4 Location Content of Warning Labels 40 6692 40 6695 4 2015 Johnson Level amp Too 8862H English_Manuals 3 19 15 3 30 P Page 5 5 Location of Part Components Output Window g Battery Cover Compensator Lock
6. 13 14 15 Self Check amp Fine Calibration Technical Specifications Application Demonstrations Care and Handling Product Warranty Warranty Registration Accessories Trouble Shooting Qty 1 1 1 3 1 1 1 Product simultaneously projects two three or five laser beams 40 6695 left right front up and down 40 6693 front up and down and 40 6692 up and down Magnetic dampening compensation system Maintains level even when affected by vibration on the job site Laser flashes and sounds an audible alarm when product is beyond leveling range Low voltage indication with power indication light flashing e Pendulum locking mechanism helps protect unit s inner mechanisms Multi functional magnetic base for attaching to tripod or any metal surface Dust and rain resistant 2015 Johnson Level amp Tool 8862H English_Manuals 3 19 15 3 30 P Page 3 3 Safety Instructions Please read and understand all of the following instructions prior to using this tool Failure to do so may void the warranty ATTENTION A IMPORTANT Read all instructions prior to operating this laser tool Do not remove any labels from tool Do not stare directly at the laser beam Do not project the laser beam directly into the eyes of others Do not set up laser tool at eye level or operate the tool near a reflective surface as the laser beam could be projected into your eyes or into the eyes of others Do not
7. 15 3 30 P Page 11 Calibration 1 Locate the back port rubber plug and side calibration port plastic plug 2 Carefully remove the rubber plug in the battery compartment and the plastic plug on the side of the laser 3 Compensator must be unlocked before making calibration adjustments 4 Use a 3mm Allen wrench 5 For adjustment to the level front beam turn the Back Figure I calibration screw clockwise to raise the beam and counter clockwise to lower the beam 6 For adjustment to the plumb beam turn the Side Figure H calibration screw clockwise to move the plumb beam away from you and counter clockwise to move the beam toward you Back Port Rubber Plug Fig Side Port Plastic Plug 2015 Johnson Level amp Tool 11 8862H English_Manuals 3 19 15 3 30 P Page 12 9 Technical Specifications Laser Wavelength Laser Classification Maximum Power Output Accuracy Interior Range Self Leveling Range Power Supply Battery Life Dimensions Weight Working Temperature Center Screw Thread IP Protection Class 635nm 10 Class Illa lt 5mW 1 8 50 ft 2mm 10m Up to 100 ft 30m depending upon light conditions 3 3 AA alkaline batteries included Approx 50 hours of continuous use 5 00 x 1 97 x 5 75 127 x 51 x 146mm 1 43 Ibs 0 65 Kg 14 F to 113 F 10 C to 45 C 1 4 20 and 5 8 11 54 2015 Johnson Level amp Too 8862H English Manuals 3 19 15 3
8. ns off after a short time clean the battery terminals and install new alkaline batteries Confirm that the On Off switch is fully engaged in the ON position If the laser is out of calibration less than 1 2 50 follow recalibration procedure in the user manual If the laser is out of calibration more than 1 2 50 contact an authorized Johnson Service Center or Johnson Level amp Tool s Customer Service Department If the laser beeps and flashes constantly place the laser on a surface that is within the self leveling range If it is still beeping and flashing it is out of calibration Follow calibration procedure in the user manual 2015 Johnson Level amp Tool 17 8862H English_Manuals 3 19 15 3 30 P Page 18 18 2015 Johnson Level amp Tool
9. serial number for your product that is located on the bottom of the unit PLEASE NOTE THAT IN ADDITION TO ANY OTHER LIMITATIONS OR CONDITIONS OF JOHNSON LEVEL amp TOOL S LIMITED WARRANTY JOHNSON LEVEL amp TOOL MUST HAVE RECEIVED YOUR PROPERLY COMPLETED WARRANTY CARD AND PROOF OF PURCHASE WITHIN 30 DAYS OF YOUR PURCHASE OF THE PRODUCT OR ANY LIMITED WARRANTY THAT MAY APPLY SHALL NOT APPLY AND THERE SHALL BE NO WARRANTY 2015 Johnson Level amp Tool 15 8862H English_Manuals 3 19 15 3 30 P Page 16 14 Accessories Johnson accessories are available for purchase through authorized Johnson dealers Use of non Johnson accessories will void any applicable limited warranty and there will be NO WARRANTY If you need any assistance in locating any accessories please contact our Customer Service Department In the U S contact Johnson Level amp Tool s Customer Service Department at 888 9 LEVELS In Canada contact Johnson Level amp Tool s Customer Service Department at 800 346 6682 16 2015 Johnson Level amp Tool 8862H English_Manuals 3 19 15 3 30 P Page 17 15 Trouble Shooting If the laser will not turn on clean the battery terminals and install new alkaline batteries Confirm that the On Off switch is fully engaged in the ON position If the laser will not illuminate clean the battery terminals and install new alkaline batteries Confirm that the On Off switch is fully engaged in the ON position If the laser tur
10. ty for each product contains various limitations and exclusions Do not return this product to the store retailer or place of purchase Non warranty repairs and course calibration must be done by an authorized Johnson service center or Johnson Level amp Tool s limited warranty if applicable will be void and there will be NO WARRANTY Contact one of our service centers for all non warranty repairs A list of service centers can be found on our web site at www johnsonlevel com or by calling our Customer Service Department Contact our Customer Service Department for Return Material Authorization RMA for warranty repairs manufacturing defects only Proof of purchase is required 14 2015 Johnson Level amp Tool 8862H English_Manuals 3 19 15 3 30 P Page 15 NOTE The user is responsible for the proper use and care of the product It is the responsibility of the user to verify the calibration of the instrument before each use For further assistance or if you experience problems with this product that are not addressed in this instruction manual please contact our Customer Service Dept In the U S contact Johnson Level amp Tool s Customer Service Department at 888 9 LEVELS In Canada contact Johnson Level amp Tool s Customer Service Department at 800 346 6682 13 Warranty Registration Enclosed with this instruction manual you will find a warranty registration card to be completed for your product You will need to locate the
11. zum 3 19 15 3 30 P Page 1 JOHNSON Self Leveling Two Three or Five Beam Laser Dot Model No 40 6692 40 6693 amp 40 6695 s an l JLT3 JUTS Instruction Manual Congratulations on your choice of this Self Leveling Two Three or Five Beam Laser Dot We suggest you read this instruction manual thoroughly before using the laser Save this instruction manual for future use These lasers either emit two three or five laser beams which projects a series of visible points on surfaces around the product 40 6695 left right front up down 40 6693 front up and down and 40 6692 up and down Beam visibility depends upon lighting conditions in the work area This is a Class Illa laser tool and is manufactured to comply with CFR 21 parts 1040 10 and 1040 11 as well as international safety rule IEC 285 2015 Johnson Level amp Tool e 8862H English_Manuals 3 19 15 3 30 P Page 2 Table of Contents 1 Kit Contents 2 Features and Functions 3 Safety Instructions 4 Location Content of Warning Labels 5 Location of Parts Components 6 Operating Instructions 7 Using the Product 1 Kit Contents Description Self Leveling Two Three or Five Beam Laser Dot Multi Functional Magnetic Base Mounting Strap AA Alkaline Batteries Magnetic Floor Target not included in 40 6692 Instruction Manual with Warranty Card Soft Sided Pouch and Hard Shell Carrying Case 2 Features and Functions 10 11 12
Download Pdf Manuals
Related Search
Related Contents
FT TIROS DTU 13 Mesh2-French manual Imperia Presto Cheese Manuale dell`utente OWNER`S MANUAL - Bowtech Archery Massive Power supply 17108/47/10 Copyright © All rights reserved.
Failed to retrieve file