Home
GSM/SMS
Contents
1. Comparison For example The exit amp delay time is set at 30 seconds single zone delay time is set at 40 seconds Sensor Arm Alarm Normal and home mode zone Delay 30s to arm Delay 30s to alarm Single delay zone Delay 30s to arm Delay 40s to alarm 24 H zone Always in arm state Alarm immediately Disarm Password The default disarm password is 1234 It is suggested to change the passcode for safety 12 13 Setting through SMS f you use a non smart phone you can set your system by sending the related SMS command codes to the SIM card in the control panel Item SMS Command Code SMS menu 2 22 System setting inquiry 00 Disarm 0 Arm 1 Home arm 2 Two way talk 3 Call back to leave a 10 second voice memo 4 Store emergency telephone numbers 5 Store emergency SMS numbers 6 Store speed dial number 8 Change zone name 901 950 Set exit amp entry delay time 11 Set alarm volume and ringing time 12 Change disarm passcode 13 Set single zone delay time 14 For example 1 Send 5 to the SIM card number of the control panel 2 You will receive a menu SMS from the control panel MEI nu A w NF H 3 Copy and edit the menu message and then send it back N C E f 1 6123456 2 6123457 E 4 5 Send 4 1 V J V M 4 You will receive a SMS
2. O2 GSM SMS Alarm System X Printed in China PA GO2 UM EN V1 2 User Manual Foreword Dear users Thank you for choosing our product This product is a totally DIY wireless home security solution It features automatic connection to various accessories putting your home under all round protection To experience this wonderful product please follow the instructions in the user manual Disclaimer Dear users We have reviewed this manual thoroughly in order that it will be an easy to use guide to this product All statements technical information recommendations in this manual are believed reliable but the accuracy and completeness thereof are not guaranteed or warranted The specifications and information regarding the products in this document are subject o change without notice Photocopy copy reproduction translation to any language modification storage in a etrieval system or retransmission in any form or by any means electronic mechanical or otherwise is strictly prohibited without prior written permission n no event we are liable for any indirect special incidental or consequential damages including without limitation lost profits or loss or damage to data arising out of the use or inability to use this document even if the product has been advised of the possibility of such damages Contents In the Box Included Accessories How It Works Accessories Remote Control Door Window
3. and please make sure they are always clean Working Mode Testing Mode After a 1 minute self test the detector enters a testing mode It detects once in every 10 seconds and emits alarm signal when motion is detected This will last for 3 minutes and then switches into power saving mode Power Saving Mode If the PIR motion detector detects movements twice in 3 minutes it automatically goes into asleep state If there is no movement detected in next 3 minutes it will switch from asleep state to arm During the 3 minutes the detector won t be active and send any signals to the control panel As long as there is a movement detected within 3 minutes the duration of power saving mode will be extended Case 2 Press the test button and then arm 3 minutes later Sleep after detecting human movement twice No human movement within 3 minutes Switch from sleep to arm Case 1 Initial start and then arm Detection Range 0m 2m 4m 6m 8m J 2 2m Z ge opis See Om Side view Pet Immune Function This sensor adopts a special design to improve detection accuracy Pets less than 25kgs will not trigger the alarm as 2 2 2m ie ee ee ee Zone Mode of Sensor Sensors can be placed in different zones for different requirements Four different zones can be selected Normal zone In arm or home arm state the detectors set
4. to normal zone work normally Once intrusion is detected the detectors trigger an alarm Home zone When system is in home arm state the detectors set to home zone are disarmed The detectors set to other zones are armed That is partial arm Single delay zone Sensors set to this zone will alarm at the specified time which can set by yourself after being triggered 24 H zone The detector set to 24 H zone trigger an alarm immediately when detecting intrusion no matter the system is armed or disarmed Sensors in This Kit Zone Mode Default Setting Door Window Contact Normal Zone PIR Motion Detector Home Mode Zone You can set zone by changing the jumpers in detector After the setting detector can work in corresponding mode It must be paired to the control panel again How to set Open the rear cover of the detector change the array of jumpers on the zone setting to the corresponding position as below Mind the direction of DO D3 H m ee ome Mode Zone Normal Zone Signal Delay Zone 24 H Zone Getting Started Step 1 Insert SIM Card B 1 AUN efore inserting the SIM card please perform the following steps ake sure the alarm system is powered off IMPORTANT Remove the default code permanently from the SIM card Turn off the voice mail function if it is enabled Insert the SIM card into the SIM card slot wait until the GSM indicator starts blinking once every 3 seconds it m
5. Contact PIR Motion Detector Zone Mode of Senso seno ete t EAR RU sony uae dds Peg en ei 8 Getting Started 2 Step 1 Insert SIM Card Step 2 Download the App Step 3 Add an Account Step 4 Be Familiar with the Alarm System 0 Step 5 System Settings 1 oup sup rel Rei te l4 Other SMS Notifications Installation Sensor Placement 5 Installation Mode Placing the Control Panel Mounting the Door Window Contact Mounting the PIR Motion Detector Pairing Deleting Accessory Pairing New Remote Control and Sensor Pairing New Wireless Siren Deleting Sensors Deleting Wireless Sireri us ort tenter e trees rae ie te UR edet Reload the Batteries of Accesories Arm amp Disarm by Free Phone Call Restore to Factory Settings Specifications Control Panel Remote Control Door Window Contact PIR Mation DST CEO ss ie ect tei Orbi aee eiae etie eter te teint In the Box m O GSM Signal Indicator Lt Voice Memo Indicator 1 2 3 J Q Call 4 5 6 0 I Record Voice Memo LI Bo 0 1 Arm Disarm Home Arm Blinks once per second Searching network Blinks once per 3 seconds Connected with network amp Blinking There is a new voice memo Enter a phone number and press this call button to make a call 4 Press and hold it for 3 seconds to leave a 10 second voice memo Press once to l
6. an record an alarm voice message by the following steps Enter disarm password default setting 1234 and then press and 10 second alarm message Distinction Voice memo Message is recorded to your family members button to leave a Alarm voice message Message is played when you pick up an emergency call Accessories Remote Control Status Indicator Arm Disarm Home Arm SOS Button System Status Press once to arm The siren beeps once to confirm the system is armed Press once to disarm The siren beeps twice confirm the system is disarmed Press once to home arm After 3 seconds the siren beeps once to confirm the system is in home mode Note The control panel only stops handling alarm signal from the home mode zone sensor which enables users to move freely at home SOS The control panel will hoot on site with indicator flashing and users will receive SMS and calls t Press the button After the indicator on the remote control blinks once press button within 3 seconds to mutely arm the system Press the 1 button After the indicator on the remote control blinks once press I button within 3 seconds to mutely disarm the system Door Window Contact The contact contains a transmitter and a magnet It can be mounted on doors windows and any other objects that can be opened or closed When the transmitter and magnet are separated ov
7. cker 2 22m Ground Step 2 Press the test button twice and walk from left to right in the room The status indicator will blink once when motion is detected Note This PIR motion detector can also be mounted at special location by using the supplied bracket and screw kits 18 Pairing Deleting Accessory The included accessories have been paired with the control panel by default if you want to pair new accessories please follow these instructions Pairing New Remote Control and Sensor Enter the disarm password default 1234 then press the amp button on the control panel and trigger the sensors once 7 When a beep is heard from the control panel the sensor is paired successfully If two beeps are heard the sensor has already been paired before I 19 DE 26 Press any button on the remote control Press the test button more than twice Separate the transmitter and the magnet over 2cm Note To pair other sensors please refer to the related user manuals a Pairing New Wireless Siren Siren is sold separately 1 Make sure the siren enters pairing sta
8. eans the network is connected Step 2 Download the App Download the App by searching keywords GO2 Alarm in the App Store or Google Play and then create your own account GO2 Alarm Q Available on the GET IT ON 0 App Store gt Google play Step 3 Add an Account Step 4 Be Familiar with the Alarm System Now you can tap 6 to arm disarm home arm your system remotely Tap and app will skip to messages interface automatically After sending the SMS you will receive a phone call from the control panel to leave a 10 second voice memo Tap and app will skip to messages interface automatically After sending the SMS you will receive a phone call from the control panel to start a two way talk 10 Step 5 System Settings Store Emergency Numbers amp SMS Numbers Emergency numbers are the phone numbers that will receive calls from the control panel when the alarm goes off SMS numbers are the phone numbers that will receive alarm SMS from the control panel when the alarm goes off IMPORTANT After phone numbers are stored only those numbers can modify the system i settings Commands from unauthorized phone numbers will be rejected Once an alarm is triggered the control panel will dial the emergency numbers 3 rounds at most if a phone is picked up with operation on phone button the system will stop dialing 1 1 I 1 1 Store Speed Dial Number Aft
9. er 2 cm the contact will send a signal to the control panel to trigger an alarm Overview Status Indicator T i Battery Tamper Switch Transmitter 1 Magnet L Zone Setting Status Indicator Blinks once Door window is opened Blinks once per 3 seconds Low battery please replace battery PIR Motion Detector The detector adopts digital dual core fuzzy logic control processing technology and intelligent analyze algorithm When human body s infrared spectrum is detected it will send alarm signal to the control panel The detector features pet immunity for animals up to 25kgs Overview oo N 2 1 Detection Lens e C 2 Status Indicator 3 Test Button e I 8 4 Bracket Slot 5 Double sided Tape Stick Place Status Indication Blinks continuously Motion detector performs a self test Blinks once Motion is detected Blinks twice Motion detector has exited testing mode and goes to power saving mode Blinks once per 3 seconds Low battery please replace battery PCB Layout Ca E E E z Tamper Switch Infrared Sensors 2 fo 2 Zone Setting c ogg 1 Status Indicator Tamper Switch When the tamper switch is pressed system will alarm immediately Infrared Sensors The infrared sensors detect movement
10. er the number is stored you can dial this number immediately by pressing button once on the control panel Change Zone Name 10 remote controls and 50 sensors could be extended and the names of sensors are able to be edited This function aims at guiding users to identify the invasion location quickly by changing the sensor name Their sequence in naming follows pairing order For example the first paired sensor is by default set to zone 1 the second paired sensor is by default assigned to zone 2 etc In case of emergency if you did not change the sensor name this control panel will send SMS with zone number to user e g Zone 1 Alarm RO Exit amp Entry Delay Time If you dont want to carry remote controls you can set the exit or entry delay Suppose entry delay was set at 30 seconds the system will allow you 30 seconds to disarm the system before alarming Suppose exit delay was set at 35 seconds the system will allow you 35 seconds to leave before the system is armed The beep is heard in every second to remind you to leave The pace of reminding sound will speed up in last 15 seconds Thus leaves you enough time to leave home without triggering the system Single Zone Delay Time To apply this function you should change the zone mode of the sensor to single delay zone first Please refer to Zone Mode of Sensor on page 9 After the time setup the single delay zone sensor will delay to alarm when it is triggered
11. for confirmation from the control panel Other SMS Notifications You will receive SMS for reminding you 1 When the control panel and sensors are in low battery the 1st stored phone number will receive a SMS 2 When the AC power of control panel fails or restores the 1st stored phone number will receive a SMS 3 When the tamper switch of sensors trigger an alarm all the stored phone numbers will receive a SMS 14 Installation Sensor Placement The alarm system is most effective with well placed sensors Determine which area you want to guard and what kind of detectors should be used The following picture is the potential places shown for different types of detectors You can refer it to choose an ideal place C Wireless Siren B Remote control A Alarm panel 1 Front door Magnet contact 2 Living area PIR motion detector 3 Window living area Magnet contact 4 Window living area Magnet contact 5 Terrace door Magnet contact 6 Window Magnet contact 7 Bedroom PIR motion detector 8 Kitchen Gas detector 15 Installation Mode There are possibilities to trigger an alarm when mounting the sensors You can press the button for 3 times on the control panel to enter the 10 minute installation mode During this period system only beeps 3 times when the sensor is triggered You can also press button on the control panel to exit this mode Placing the control panel There are two insta
12. he alarm system can be done by calling the SIM card No in the control panel Do not hang up until the system disconnected by itself The alarm system will not call you back and the system is disarmed Restore to Factory Settings Send text 0000 to the control panel the system will be restored to factory settings but the paired sensors remain working 22 Specifications Control Panel Power Supply Battery GSM Frequency Standby Current Alarm Current Internal Siren Expandable Accessories Radio Frequency Housing Material Operating Condition Control Panel Dimensions Bracket Dimensions Remote Control Power Supply Transmit Current Transmitting Distance Radio Frequency Housing Material Operating Condition Dimensions 23 DC12V 500 mA 3 7V 600 mAh Li ion Battery 850 900 1800 1900 MHz lt 56 mA lt 270 mA 90 dB 10 Remote Controls 50 Sensors 315 MHz or 433 92 MHz ABS Plastic Temperature 10 C 55 C Relative Humidity lt 80 non condensing 125 x 150 x 30 mm L x W x H 87 5 x 81 5 x 12 mm Lx W x H DC 3V CR2025 lithium battery x 1pc lt 7 mA lt 80 m open area no interference 315 MHz or 433 92 MHz ABS Plastic Temperature 10 C 55 C Relative Humidity lt 80 non condensing 53 x 31x 11mm LxWxH Door Window Contact Power Supply Static Current Alarm Current Transmitting Distance Radio Frequency Housing Material Operating Condition Transmitter Dimens
13. ions Magnet Dimensions PIR Motion Detector Power Supply Static Current Alarm Current Detection Scope Transmitting Distance Radio Frequency Housing Material Operation Condition Detector Dimensions Bracket Dimensions DC 3V CR2032 lithium battery x 2pcs 5 uA 9 mA 80 m open area no interference 315 MHz or 433 92 MHz ABS Plastic Temperature 10 C 55 C Relative Humidity 8096 non condensing 71x31 5x15 mm Lx W x H 71x12 5x 15 mm LxWxH DC 3V AA 1 5V LR6 battery x 2 pcs 50 uA 9 5 mA 8m 110 80 m open area no interference 315 MHz or 433 92 MHz ABS Plastic Temperature 10 C 55 C Relative Humidity lt 80 non condensing 100 x 59 x 43 mm L x W x H 52 x 30 x 26 5 mm L x W x H 24
14. isten to a new voice memo or replay ll n SIM Card Slot E bg i of Power On Off L Ey Adapter Jack 4 l System Status Arm Press 3 to arm your system Now all the sensors are on guarding Disarm Enter the password default setting 1234 and press I to disarm your system Now your system stops handling alarm signal from sensors except these sensors in 24 H zone home Home Arm Press to part arm your system Now your system only stops handling alarm signal from home mode zone sensors which enables users to move freely at Included Accessories 77 his alarm system has the following accessories included in the box p PIR Motio Detector x 1 Door Window Contact x 1 Remote Control x 2 AC Adapter x 1 User Manual x 1 How It Works The control panel will receive an alarm signal when a sensor is triggered it will hoot and inform users by sending SMS and making calls When you receive a phone call from the control panel you will hear your pre recorded alarm voice message first and then you can remotely control the system by pressing the numbers on your phone keyboard Operation Function 0 Disarm 1 Arm 6 Turn off siren 9 Turn on siren Two way talk Hang up You c
15. llation methods for users The one is placing the control panel on the desk the other one is mounting it on wall by using the supplied screw kit Please choose an ideal place and suitable method to mount your control panel 16 17 Mounting the Door Window Contact Make sure the contact works properly before installation Step 1 Choose a suitable installation location It can be installed on doors windows or any other objects that can be opened or closed If it is applied to metal doors please place a spacer under the transmitter and magnet Step 2 Secure the contact with the supplied sticker Make sure the gap marks on the side of transmitter and magnet are closed to each other and within the range of 1cm As long as the space between transmitter and magnet is over 2cm The status indicator on the transmitter will blink once Mounting the PIR Motion Detector Important Avoid installing the motion detector directly towards windows and near heat Sources such as heat extraction units air condition micro wave oven refrigerator etc Avoid placing two motion detectors in the opposite of each other Don t place them in each other s detection range ax g a 7 p e a f Step 1 The ideal mounting height of the motion detector is 2 2 2 meters from the floor t is suggested to mount it at the corner of the wall by using the supplied 3M sti
16. te please refer to relevant user manual 2 Press A or amp j on the control panel to send out a pairing signal to the siren When a beep is heard from the siren the siren is paired successfully If two beeps are heard the siren has already been paired before i If a wireless siren is paired you can turn on or off the arm disarm tone by sending 63701 or 63700 to the control panel The default setting is off Deleting Sensors Send SMS with content 21 to the control panel then you will receive an SMS to confirm the successful deletion of sensors Send SMS with content 23 to the control panel then you will receive an SMS to confirm the successful deletion of remote controls Deleting Wireless Siren Press and hold the pair button of the wireless siren the deletion is succeeded when two beeps are heard from the wireless siren 20 21 Reload the Batteries of Accessories Remote Control Loose the screw Open the case and change the battery Door Windor Contact Open the case and change the battery PIR Motion Detector Loose the screw Open the case and change the battery Arm amp Disarm by Free Phone Call Arming the alarm system can be done by calling the SIM card No in the control panel Hanging up the call after you hear the dialing tone and then you will be called by the control panel do not answer the phone call and the system will be armed Disarming t