MOVI-PLC advanced Controller Remote Maintenance via ORA11B
Contents
1. eee eeccccccc ORA11B eo w eeeeccc MOVI PLC advanced Controller Remote Maintenance via ORA11B Edition 09 2008 Manual 16717228 EN SEW EURODRIVE Driving the world General NOES a raaa eiai aaiae iaiia 4 1 1 Use of the mania keni ER 4 1 2 Structure of the safety 6 4 1 3 Right to claim under warranty cre erenneren eeuna e emen 5 1 4 Exclusion of liability irte te e reed 5 1 5 Copyright notice ite rette e e e rtt ce Ede te eee 5 PR 6 2 1 Preliminary information 6 2 2 EE 6 2 3 Fargo oroo oa E ra 6 2 4 Designated use n tees d i P 7 2 5 Operation 7 2 6 Installation reais eae Rr RR eS ee ee 7 2 7 Other applicable documentation 7 AT a N 7 System Description ico 8 3 4 Remote maintenance via the ORA11B 8 Assembly and Installation Notes
2. is n m 64174AXX Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 11 4 Assembly and Installation Notes Step by step instructions for removing ORA11B from a DIN rail Move and hold the screwdriver towards the ORA11B see following figure This draws apart the plastic spring of the movable latch hook 64185AXX First pull ORA11B forward and then upward and away from the DIN rail see follow ing figure 64181AXX 12 Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Assembly and Installation Notes Connections and terminals at the front of ORA11B 43 Connections and terminals at the front of ORA11B The following figure shows the connections and control elements of the ORA11B option necessary for remote maintenance OQOOOOOOOOOOQOO ORA11B A RJ45 Line r 3 LAN 2 INIL LAN4 Power Chom 4 5 O Data 6 Q Status RODRI e 64063AXX 1 Reset button 2 Telephone connection RJ45 plug connector 3 4 port Ethernet switch LAN 1 LAN 4 for network connection 4 PowerLED 5 COMLED 6 Data LED 7 Status LED 4 3 4 Reset button Operation Meaning Press once briefly Resets ORA11B via software
3. Deutsch Engish display hep text Basic Settings Dial In Dial Out Portforwarding EURODRIVE EZ 12023AEN NOTE Do not use the browser button Update to update the content of the page To update the content of a page confirm your entries by clicking on OK in the configuration interface Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 23 Configuration Establishing a remote maintenance connection via ORA11B 5 4 Establishing a remote maintenance connection via ORA11B Proceed as follows L Bl Programs 1 First call up the network connection wizard see following figure To do so select Start Settings Network and Dial up Connections Make New Connection Documents Settings Taskbar amp Start Menu 2k Local Area Connection Control Panel Network and Dial up Connections S3 make New Connection Eg Search 4 Printers 2 Help ai g Run Local Area Connection 2 Shut Down The network wizard is called 12031AEN 2 Select the network connection type Select the Dial up to private network radio but ton see following figure Network Connection Wizard Network Connection Type You can choose the type of network connection you want to create based on your network configuration and your networking needs Dial up to private network Connect using my phone line mode
4. Paper Cutter H Ethernet Eje 0 DHE B 1 Axis_1 B 2 Axis_2 B 3 Axis_3 Remote system location SBus Ethernet MOVI PLC advanced Axis 1 Axis 2 Axis 3 64004AEN Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B System Description Remote maintenance via the ORA11B modem Scope of delivery The scope of delivery of the ORA11B option part number 1822 005 3 consists of option 2telephone cables TAE N to RJ12 and RJ12 to RJ12 each 3 m long Optional scope Telephone adapter set for Europe suitable for Belgium France Italy Austria of delivery Switzerland part no 1811 216 1 Content of this This user manual describes the hardware required for remote maintenance of the manual MOVI PLC advanced controller and how a connection is established via the ORA11B modem NOTE For further function descriptions refer to the online help of the configuration interface of ORA11B Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 4 Assembly and Installation Notes Step by step instructions for mounting ORA11B to a DIN rail 4 Assembly and Installation Notes 4 1 Step by step instructions for mounting ORA11B to a DIN rail Proceed as follows Moisture and liquids can enter the interior of the ORA11B Severe or fatal injuries from electric shock ORA11B may not be used in wet or moist environments e g close to wate
5. Pinging 192 168 10 3 with 32 bytes of data from 192 168 10 3 bytes 32 time 17ims TTL 64 from 192 168 180 bytes 32 time 172ms TTL 64 from 192 168 10 3 bytes 32 time 156ms TTL 64 from 192 168 18 3 bytes 32 time 156ms TTL 64 ics for 192 168 16 3 Sent 4 Received 4 Lost 9 6 loss gt Approximate round trip times in milli seconds Minimum 156ms Maximum i 2ms Average 163ms 12042AEN MOVI PLC advanced also responds to a ping command see following figure C MINNT system32scmd exe 192 168 10 4 Pinging 192 168 10 4 with 32 bytes of data Reply from 192 168 10 4 bytes 32 time 219ms TTL 254 from 192 168 10 4 bytes 32 time 15 ms TTL 254 from 192 168 10 4 bytes 32 time 172ms TTL 254 from 192 168 10 4 bytes 32 time 15 ms TTL 254 statistics for 192 168 16 4 Packets Sent 4 Received 4 Lost loss gt D Approximate round trip times in milli seconds Minimum 15 ms Maximum 219ms Average 176ms CM 12043AEN Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 31 32 Configuration Establishing a connection on the engineering PC The file NetConfig cfg of MOVI PLC advanced must contain the following entries under Ethernet 2 lt Ethernet2 gt lt IPAddress gt 192 168 10 4 lt IPAddress gt lt Netmask gt 255 255 255 0 lt Netmask gt lt Ethernet2 gt 5 6 Establishing a connection on the engineering PC Select the entry Ethernet 1
6. in MOVITOOLS MotionStudio under Network communi cation connections Tick the Activate checkbox 2 then press the Edit button 3 see following figure 1 2 Configure communication plugs Activate Ethercat No Activate Activate SMLP Yes russe 3 D Activate H Abbrechen 64000AEN Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Configuration Establishing a connection on the engineering PC Select the SMLP settings 1 tab In the Basic settings group box in the input field Broadcast IP Address 2 enter the IP address of MOVI PLC advanced see follow ing figure 1 Ethernet 1 SMLP settings Ethercat settings IV Activate SMLP Basic settings Timeout 2 Broadcast IP address 92 168 10 255 Broadcast scan duration 5 5 EX 5 Address listings 10000 H ms Default value Yes Default 1000 ms Network adapter Default 5s IP addresses of SMLP servers Excluded IP addresses i 64003AEN As a result the MOVI PLC advanced is also found in the online scan and the PLC Editor can be started as usual NOTES able in the menu items e MOVITOOLS MotionStudio Proposal 15000 ms tings Proposal 10000 ms PLC Editor Project Work area Proposal 8000 ms fective before a timeout of a lower level Settings Options Com
7. 192 168 10 2 Set 255 255 255 0 as subnet mask Select the following menu items to make the settings Start Settings Network Connections Highlight the existing network connection and right click on the menu item Proper ties Tick the Internet protocol TCP IP checkbox in the LAN connection proper ties window The Internet Protocol TCP IP Properties window will open see fol lowing figure General You can get IP settings assigned automatically if your network supports this capability Otherwise vou need to ask your network administrator for the appropriate IP settings C Obtain an IP address automatically r Use the following IP address IP address 192 168 10 2 Subnet mask 255 255 255 0 Default gateway j C Gbten DNS server address automatically r Use the following DNS server addresses Preferred DNS server Altemate DNS server Cancel 12021AEN Confirm your entries with OK Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Configuration Configuration of ORA11B 3 Select Internet Options from Start System Configuration The Internet Proper ties window is displayed see following figure Select the Connections tab 1 and click on LAN Settings 2 in the Local Area Network LAN Settings field 1 General Security Content Connections Programs Advanced D Use the Internet Con
8. 2 1 78 File and Printer Sharing for Microsoft Networks 3 Client for Microsoft Networks Install Uninstall Properties 4 General DNS WINS Options This checkbox only applies when you are connected to a local network and a dial up network simultaneously When checked data that cannot be sent on the local network is forwarded to the dial up network PPP link Use IP header compression 63998AEN If you want to continue using an existing company intranet while the modem connec tion is active you have to deactivate the Use default gateway on remote network checkbox 5 on the General tab Confirm your entries with OK NOTE Internet access is only available when the modem connection has been deactivated 28 Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Configuration 5 Establishing a remote maintenance connection via ORA11B 11 In the last step select the menu items Start Settings System configuration System Hardware Device manager Modems Select the used modem Make a right mouse click to open the context menu and choose Properties see following figure Agere Systems AC 97 Modem F 3 xl General Modem Diagnostics Advanced Driver Resources Port COM4 Speaker volume m Maximum Port Speed 115200 m Dial Control Cancel 63999AEN Since
9. MOVI PLC advanced Controller Remote Maintenance via ORA11B 21 Configuration Configuration of ORA11B 5 3 3 Changing default settings Once ORA11B has been connected to the PC via a patch or crossover cable you can enter the default IP address 192 168 10 3 in the browser You have to enter your user name and password to avoid unauthorized access see fol lowing figure The default settings are Username SEW Password ORA11B J about blank Microsoft Internet Explorer n xl File Edt View Favorites Tools Help EJ Heak gt A bo Bsearch Favorites Ty Address 192 168 10 3 ee Enter Network Password ixl 7 Please type your user name and password Site 192 168 10 3 Ream UserName SEW PBewed f Save this password in your password list Cox zi 12022AEN Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Configuration 5 Configuration of ORA11B After logging in successfully the start page of ORA11B opens see following figure You can enter the default settings see chapter 5 3 1 under the respective menu item For more information refer to the online help under Display help text FJ SEW EURODRIVE Microsoft Internet Explorer Datei Bearbeten Anskht Favorten Extras 7 Harek gt 7 suchen sgFavoiten Preden Al D SOO Adresse 48 http 192 168 10 3
10. and restarts it Hold for at least 3 seconds Resets the hardware of ORA11B and restarts it Pressing it 3 times in quick succession Deletes all settings of ORA11B and resets the unit to the within 2 seconds factory settings Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 13 Assembly and Installation Notes Connections and terminals at the front of ORA11B 4 3 2 Connecting ORA11B to an analog telephone line To connect the modem to the analog telephone line use the supplied connection cable TAE N to RJ12 alternative RJ12 to RJ12 Insert the RJ12 plug connector 2 in the RJ45 socket of the ORA11B and the TAE N plug connector 1 in the telephone jack see following figure ORA11B 2 LAN2 A vans RJ45 Line O Pow 1 Pad EW Q Status ooooooooeooooo 64202AXX NOTE If the connection cables included in the scope of delivery do not fit your telephone jack you can use the telephone adapter of the optional telephone adapter set Europe part no 1811 216 1 from SEW EURODRIVE The Europe telephone adapter set can be used in the following countries Belgium France e Italy Austria Switzerland Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Assembly and Installation Notes Connections and terminals at the front of ORA11B The following table shows the pin as
11. can have live bare and movable or rotating parts as well as hot surfaces depending on their enclosure Severe or fatal injuries All work related to transportation storage setup mounting connection startup maintenance and repair may only be carried out by qualified personnel in strict ob servation of The relevant detailed operating instructions Warning and safety signs on the units All other relevant project planning documents operating instructions and wiring diagrams The specific regulations and requirements for the system National regional regulations governing safety and the prevention of accidents Never install damaged products Submit a complaint to the shipping company immediately in the event of damage Removing covers without authorization improper use as well as incorrect installation or operation may result in severe injuries to persons or damage to property Refer to the documentation for additional information 23 Target group Only qualified personnel is authorized to install startup or service the units or correct unit faults observing IEC 60364 or CENELEC HD 384 or DIN VDE 0100 and IEC 60664 or DIN VDE 0110 as well as national accident prevention guidelines Qualified electricians in the context of these basic safety notes are persons familiar with installation assembly startup and operation of the product who possess the required qualifications Manual MOVI PLC advance
12. continue 5 Inthe Smart cards window select the Do not use my smart card radio button see following figure Network Connection Wizard Smart Cards You can use your smart card with thes connection j You can configure this connection to use your smart card to log you into the remote network Select whether to use your smart card wath this connection 12035AEN Click Next to continue 6 In the Connection availability window select the For all users radio button see following figure Network Connection Wizard Connection Availability You may make the new connection available to all users or just yourself You may make this connection available to all users or keep it only for your own use A connection stored in your profile will not be available unless you are logged on Create this connection For all users C Only for myself 12036AEN Click Next to continue Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 25 5 Configuration Establishing a remote maintenance connection via ORA11B 7 To complete the network connection wizard enter aname for the modem connection e g remote maintenance and tick the Add a shortcut to my desktop checkbox siehe following figure Network Connection Wizard Completing the Network Connection Wizard Type the name you want to use for this connection Remote Maintenance To create this connection and save it i
13. dial up is to be via an outside line deactivate the checkbox Wait for dial tone before dialing 1 in the Dial control field Confirm your entry with OK Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 29 5 Configuration Testing the modem connection 5 5 Testing the modem connection Click the Dial button to close test the modem connection Connect Remote Maintenance 21 x User name SEW Password n Save password Dial oor 23456789 Cancel Properties Help 12038 The connection is established see following figure Connecting Remote Maintenance sg Dialing 00123456783 E Cancel 12039AEN To display the status of the modem connection highlight the shortcut on the desktop right click on it and select Status from the context menu see following figure Disconnect 12040AEN 30 Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Configuration 5 Testing the modem connection The status of the modem connection is displayed see following figure General Details r Connection Status Connected Duration 00 01 29 Speed 33 6 Kbps Activity Sent ap Received LS Bytes 4 768 426 Compression 0 0 0 2 Properties Disconnect 12041AEN Now ORA11B responds to a ping command see following figure le C WINNT system32 c C gt ping 192 168 10 3
14. eeeeereeeeeeeeereneen nnne 10 4 1 Step by step instructions for mounting ORA11B to a DIN rail 10 4 2 Step by step instructions for removing ORA11B from a DIN rail 11 4 3 Connections and terminals at the front of ORA11B n se 13 4 3 1 Reset HUO nme REED 13 4 3 2 Connecting ORA11B to an analog telephone line 14 4 3 3 Connecting MOVI PLC advanced to 16 4 3 4 Operating displays of the ORA11B 16 4 4 Connections and terminals at the bottom of 17 4 4 1 Voltage supply of ORA11B ssssssssseeee emen 17 18 5 1 Used components topology seeennn nnn 18 5 2 Overview of assigned IP addresses ssssssseeee 18 5 3 Configuration of ORA11B sssssssssssssseeeeeeennee nennen ennt nnne 19 9 3 1 Default SettingS eet 19 5 3 2 Establishing a network connection to the ORA11B modem 20 5 3 3 Changing default settings 20 0 0 22 5 4 Establishing a remote maintenance connection via ORA11B 24 5 5 Testing the modem connection essssseenenenn 30 5 6 Establishing a connection on the engineeri
15. g electric shock CAUTION Possible damage to property Damage to the drive system or its environ ment NOTE Useful information or tip Simplifies handling of the drive System Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B General Notes Right to claim under warranty 1 3 Right to claim under warranty You must observe this manual as the prerequisite for fault free operation and fulfillment of any right to claim under warranty Therefore read the documentation before you start working with the software and the connected units from SEW EURODRIVE Make sure that the documentation is available to persons responsible for the system and its operation as well as to persons who work independently on the unit You must also ensure that the documentation is legible 1 4 Exclusion of liability You must observe this manual and the documentation of the connected units from SEW EURODRIVE to ensure safe operation and to achieve the specified product character istics and performance requirements SEW EURODRIVE assumes no liability for injury to persons or damage to equipment or property resulting from non observance of these operating instructions In such cases any liability for defects is excluded SEW EURODRIVE guarantees that the software is free from deficiencies in title and that it can be used for the purposes for which it is intended Beyond this there is no guar antee for technical details
16. or suitability for a certain purpose SEW EURODRIVE will not be liable for damage delays or impediments to performance beyond our area of responsibility or for damage as a result of inappropriate improper or unintended use of the software 1 5 Copyright notice 2008 SEW EURODRIVE All rights reserved Any reproduction modification distribution or unintended use in whole or in part is pro hibited Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Safety Notes Preliminary information 2 Safety Notes The following basic safety notes are intended to prevent injury to persons and damage to property The operator must make sure that the basic safety notes are read and ob served Ensure that persons responsible for the machinery and its operation as well as persons who work independently have read through the documentation carefully and understood it If you are unclear about any of the information in this documentation or if you require further information please contact SEW EURODRIVE 2 1 Preliminary information The following safety notes refer to the operation of the ORA11B If you use other SEW components also refer to the safety notes for the relevant components in the corre sponding documentation Please also observe the supplementary safety notes in the individual sections of this documentation 22 General information A HAZARD During operation the connected units
17. 2 MNP 10 MNP10 EC MNP 5 V 42bis V 44 Supported transmission standards V 32bis V 32 V 23 V 22 V 22bis V 21 V 34 V 34 for 56 version also V 90 and V 92 Bell Norm 103 212 LAPM 4 port Ethernet switch 10 100 MBit s full half duplex autosense Automatic wiring recognition Crossover or Patch Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Index 7 Index A Assembly and installation notes 10 Configuration sinesinde 18 Establishing a connection on the engineering PC 32 Establishing a remote maintenance connection via ORAT1B 24 Overview of assigned IP addresses 18 Testing the modem connection 30 Used components topology 18 Connecting MOVI PLC advanced to ORA11B 16 Connecting ORA11B to an analog telephone line 14 Connections and terminals at the bottom of ORA11B 17 Voltage supply of ORAT1B 17 Connections and terminals at the front of ORA11B sssssssssss 13 Content of this manual 9 Copyright NOCE ari E TRE 5 E Establishing a connection on the engineering PC 32 Establishing a remote maintenance c
18. IP addresses must be in the network defined by the net mask This network must be dif ferent from existing local networks check with the IT department if necessary Engineering PC LAN connection IP address 192 168 10 2 Net mask 255 255 255 0 Remote data transmission connection The IP address 192 168 1 254 is sent from the ORA11B modem to the RDT link of the engineering PC while the connection is established ORA11B e Router switch IP address 192 168 10 3 Net mask 255 255 255 0 Modem Local address of the PPP connection 192 168 1 253 P address of the remote end 192 168 1 254 MOVI PLC address 192 168 10 4 advanced Net mask 255 255 255 0 18 Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Configuration Configuration of ORA11B 5 3 Configuration of ORA11B 5 3 1 Default settings The ORA11B modem has been configured with the following default settings Menu Basic Settings Web Interface Authentication User name SEW Password ORA11B Menu Basic Settings IP Addresses LAN IP address 192 168 10 3 Net mask 255 255 255 0 Menu Dial In Activate dial in Yes Idle time 0s Rings before call is answered 2 Activate NAT Activated Authentication for dial in Activated User name SEW Password ORA11B Authentication via PAP IP addres
19. Maximum speed bps 115200 pons Modem protocol x Use dialing rules Fhe Hardware features IV Enable hardware flow control IV Show icon in taskbar when connected Enable modem error control DK Cancel Initialization Show terminal window Run script Edi Cancel 2 Enable modem speaker 63997AEN If necessary deactivate the Enable modem compression 2 checkbox in the Hard ware features group Confirm your entries with OK Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 27 5 Configuration Establishing a remote maintenance connection via ORA11B 10 Select the Networking tab In the Components checked selection field deacti vate the checkboxes File and printer sharing for Microsoft networks 2 and Client for Microsoft network 3 see following figure on the left Activate the Internet protocol TCP IP checkbox 1 and click the Properties but ton 4 The Properties TCP connection window will open You do not have to set anything here Click the Advanced button The Advanced TCP IP settings window appears see following figure General Options Security Networking Sharing 31 xl Type of dial up server am calling Windows 95 98 NT 4 2000 Internet Settings Components checked are used by this connection 1 Y Intemet Protocol TCP IP
20. d Controller Remote Maintenance via ORA11B Safety Notes Designated use All activity in the other areas of transportation storage operation and disposal must be carried out by persons who are appropriately trained 24 Designated use 1 is an analog modem with integrated router and a 4 port switch which allows remote access to connected units It can be used to establish a connection via an analog phone line for example to a remote facility Technical data and information on the con nection requirements are provided on the nameplate and in the documentation these must be observed under all circumstances 25 Operation A WARNING Unwanted operating statuses of the system Severe or fatal injuries An interruption of the communication link between the system and the remote mainte nance station can lead to unwanted operating statuses Make sure that instructed staff has implemented safety measures on site 26 Installation The connected units must be installed and cooled according to the regulations and spec ifications in the corresponding documentation The connected units contain components that can easily be damaged by electrostatic energy and improper handling Prevent mechanical damage or destruction of electric components may pose health risk The following applications are prohibited unless the unit is explicitly designed for such use Usein potentially explosive areas Use
21. in areas exposed to harmful oils acids gases vapors dust radiation etc 2 7 Other applicable documentation The following publications and documents apply to the connected units Operating instructions manuals of the units Units are for example MOVI PLC MOVIDRIVE B etc Forunits with functional safety technology also the respective Safe Disconnection Manual Conditions manuals 2 8 Disposal Observe current national regulations Dispose of the individual materials separately in accordance with the country specific regulations in force Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B System Description Remote maintenance via the ORA11B modem 3 System Description 3 1 Remote maintenance via the ORA11B modem Remote maintenance is a key tool in ensuring that the best possible worldwide support is provided for MOVI PLC advanced ISDN lines are not available everywhere and ac cess via Ethernet is often not possible due to network administration requirements In this case using an analog modem connection is the best alternative ORA11B offers an analog modem a router and a 4 port switch It can be used to estab lish a connection via an analog phone line to a remote facility This enables the usual access to the MOVI PLC advanced controller and all units connected to the system bus Engineering PC with analog modem Project Edit Network Vie Dc a Paper Cutter
22. m or ISDN Click Next to continue 12032AEN 3 Select the unit you want to use for establishing the connection Tick the Modem checkbox see following figure Network Connection Wizard Select a Device This is the device that will be used to make the connection fou have more than one dial up device on your computer Select the devices to use in this connection S Infrared Modem Port SERIAL1 0 FS 5 Modem Age Modem COM4 Click Next to continue 12033AEN 24 Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Configuration 5 Establishing a remote maintenance connection via ORA11B 4 Enter the call number of the network to which you want to establish a connection see following figure To dial out of a private phone system an outside line must first be selected by entering a 0 The comma after the 0 represents a pause that will last long enough to obtain the outside line The full number is then dialed Network Connection Wizard Phone Number to Dial You must specify the phone number of the computer or network you want to connect to Type the phone number of the computer or network you are connecting to If you want your computer to determine automatically how to dial from different locations check Use dialing rules rea code Phone number z 23456789 Country region code zi Use dialing rules 12034AEN Click Next to
23. munication timeout To establish a stable connection you probably have to increase the timeout settings in MOVITOOLS MotionStudio and in the PLC Editor The timeout settings are avail Network Configure communication connections Ethernet SMLP set These suggested timeout settings prevent that a timeout of higher level becomes ef Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 33 Technical Data General technical data 6 Technical Data 6 1 General technical data 34 General technical data of ORA11B Operating voltage DC 10 60 V Power consumption in standby mode 2W Power consumption when connection is active 3 W Input level High level 4 12 V Low level 0 1 V Current consumption of an active input against GND internal 5 V Typically 0 35 mA Switch output max switching voltage DC 30 V AC 42 V Switch output max current load DC1A ACO 5A Weight 300 g Dimensions width x height x depth 70 mm x 110 mm x 75 mm Temperature range 0 C 55 C Maximum permitted humidity 95 non condensing Protection class Housing IP40 Screw terminals IP20 Technical data of ORA11B modem Technical data of ORA11B modem Communication interface for incoming and out going PPP connections Analog 56k modem Transmission rate 56 kB s Supported data compression standards Fax Class 1 2 MNP 2 3 4 V 4
24. n 6 Target group eene 6 Scope of delivery ORA11B 9 Structure of the safety notes 4 System description senes 8 Remote maintenance via ORA11B 8 T Technical data essen 34 Testing the modem connection 30 V Voltage supply of ORA11B 17 Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Drive Technology Drive Automation System Integration Services How we re driving the world With people who With comprehensive With uncompromising think fast and With a worldwide With drives and controls knowledge in virtually quality that reduces the develop the service network thatis that automatically every branch of cost and complexity of future with you always close at hand improve your productivity industry today daily operations SEW EURODRIVE 1 Driving the world With a global presence With innovative With online information that offers responsive technology that solves and software updates and reliable solutions tomorrow s problems via the Internet available Anywhere today around the clock SEW EURODRIVE GmbH amp Co KG P O Box 3023 D 76642 Bruchsal Germany Phone 49 7251 75 0 Fax 49 7251 75 1970 sew sew eurodrive com WWW Sew eu
25. n the Network and Dial up Connections folder click Finish To edit this connection in the Network and Dial up Connections folder select it click File and then click Properties Add a shortcut to my desktop lt Back Cancel 12037AEN Click on the Finish button The Connect Remote Maintenance window opens 8 Before you can select anything you have to enter more settings see following figure Enter your user name and password here Connect Remote Maintenance 2 x User name Password Dial n Save password 0 0123455783 M Cancel Properties Help 12038 Click the Properties button The Remote Maintenance window opens 26 Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Configuration 5 Establishing a remote maintenance connection via ORA11B 9 Select the General tab In the Connect using selection field tick the Modem checkbox Click the Configure button 1 The Modem Configuration window is displayed see following figure Remote Maintenance 21x General Options Security Networking Sharing Connect using amp Modem Agete Systems AC S7 Modem COM 4 O Infrared Modem Port SERIAL1 0 IV All devices call the same numbers Configure Phone number Modem Configuration 2 Phone number Agere Systems AC S Modem 4 fi2 Alternates EE at a ee
26. nection Wizard to Im connect your computer to the Internet i Setup Dial up settings 2 Remote Maintenance Add Remove di Settings Never dial a connection Dial whenever a network connection is not present C Always dial my default connection Local Area Network LAN settings Automatic configuration Automatic configuration may override manual settings To ensure the OK Cancel use of manual settings disable automatic configuration Automatically detect settings Use automatic configuration script Proxy server 3 Use a proxy server 21 iussa Advanced ITI cma 63987AEN The Local Area Network LAN Settings window opens If necessary deactivate the Use a proxy server 3 checkbox in the Proxy server group This only needs to be done to access the ORA11B configuration page After successful configuration you can re activate the Use a proxy server checkbox so that you can access other web sites or the configuration interface via the dial up connection NOTE The proxy server still needs to be deactivated and reactivated when a second net work card has been installed in the engineering PC To bypass the proxy server for local addresses click on Advanced 4 to add the IP address of ORA11B to the list of exceptions as an alternative to deactivating activating the proxy server Manual
27. ng 32 Techrical ree Ud ni 34 6 1 General technical data ssssssssssssseeeeseeeee nennen enne nnn 34 6 2 Technical data of ORA11B modem sse 34 HD qm 35 Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B General Notes Use of the manual 1 General Notes 1 1 Use of the manual The manual is part of the product and contains important information on operation and service The manual is written for everyone starting up or servicing this product The manual must be accessible and legible Make sure that persons responsible for the system and its operation as well as persons who work independently on the unit have read through the manual carefully and understood it Consult SEW EURODRIVE if you have any questions or if you require further information 1 2 Structure of the safety notes The safety notes in this manual are designed as follows Symbol A SIGNAL WORD Nature and source of hazard Possible consequence s if disregarded Measure s to avoid the hazard Symbol Signal word Meaning Consequences if disregarded Example Imminent hazard Severe or fatal injuries A WARNING Possible hazardous situation Severe or fatal injuries General hazard A CAUTION Possible hazardous situation Minor injuries Specific hazard e
28. onnection via ORA11B 24 Exclusion of liability 5 G General notes 4 Exclusion of liability esses 5 Right to claim under warranty 5 Structure of the safety notes 4 Use of the manual sese 4 Introduction Content of this manual 9 M Mounting and installation notes Connections and terminals at the front of ORAT11B 13 Mounting ORA11B to a DIN rail 10 Removing ORA11B from a DIN rail 11 Mounting ORA11B to a DIN rail 10 0 Operating displays of ORA11B 16 Other applicable documentation 7 Overview of assigned IP addresses 18 R Remote maintenance via ORA11B 8 Removing ORA11B from a DIN rail 11 Reset button sss 13 Right to claim under warranty 5 S Safety Notes Disposal koci E 7 Safety notes dera 6 Designated use 7 General doit Ra diea 6 Installation 7 ODOration t asit et cepe qiie 7 Preliminary informatio
29. rcours es Install ORA11B in a dry place that is protected against splashing water Switch off the power supply of the control cabinet and secure it against being switched back on inadvertently before mounting or removing the unit There are 3 latch hooks on the back of the ORA11B see following figure Two latch hooks 1 2 are located at the outer edge the third latch in the center 3 is movable 3 64182AXX Position the ORA11B with both latch hooks on the outer edge on the DIN rail accord ing to the following figure Rotate the ORA11B down towards the DIN rail until the movable latch hook clicks audibly 3 CLACK ui 64173AXX ORA11B is now installed 10 Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Assembly and Installation Notes 4 Step by step instructions for removing ORA11B from a DIN rail 4 2 Step by step instructions for removing ORA11B from a DIN rail Proceed as follows A HAZARD Open electric components Severe or fatal injuries from electric shock Switch off the power supply of the ORA11B and secure it against being switched back on inadvertently before removing the unit Remove all plug connectors nserta screwdriver with blade width 4 5 mm in the movable latch hook see following figure NNNNS i D
30. rodrive com
31. ses for PPP connection WAN Own IP address 192 168 10 253 IP address of the remote end 192 168 10 254 NOTES If you reset ORA11B by performing a unit reset see chapter 4 3 1 all deviating settings e g IP address will be reset to the default settings Chapters 5 3 2 and 5 3 3 describe how you can change the default settings Goto chapter 5 5 if you want to establish a remote maintenance connection with ORA11B with the default settings Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 19 20 Configuration Configuration of ORA11B 5 3 2 Establishing a network connection to the ORA11B modem ORA11B is configured via a network connection between ORA11B and a PC NOTE We recommend to use a second network card in the PC This avoids interrupting an existing network connection and re configuring it Based on the default settings of ORA11B you have to set up a network connection as follows 1 Internet Protocol TCP IP Properties For the default settings of ORA11B press the reset button of ORA11B three times Do not hold down the button for any longer than 1 second at a time You must press the button three times within 2 seconds The default IP address 192 168 10 3 is found on the housing of ORA11B The IP ad dress of the PC must be different from the IP address of ORA11B However the IP address of the PC must be from the same network e g
32. signment of the RJ12 and TAE N plug connectors Ww EN A 4 i b2 8 1 M E 123456 RJ12 TAE N 64178AXX RJ45 TAE N Pin Description 1 E Not connected 2 a2 For connecting a downline telephone 3 a1 Fi 5i Incoming telephone line outside line or extension line 5 b2 For connecting a downline telephone 6 W Not connected Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Assembly and Installation Notes Connections and terminals at the front of ORA11B 4 3 3 Connecting MOVI PLC advanced to ORA11B Use an Ethernet cable RJ45 to RJ45 to connect X37 of the MOVI PLC advanced con troller with an Ethernet switch LAN 1 LAN 4 of the ORA11B option see following figure ORA11B Ir y o Q Power Ocom Q Data Q Status o pe c LAN2 AE Lana s 64204AXX 4 9 4 Operating displays of the ORA11B option The ORA11B option has 8 LEDs that display the current status of ORA11B and the re mote maintenance connection Designation Di
33. splay Meaning 4 switch port status LEDs Yellow Link with 10 MBit s one LED each at LAN1 2 Green Link with 100 MBit s 3 4 LED flashes data transfer Power LED Green Supply voltage is present COM LED Green Establishing modem connection Orange Modem connection is established Data LED LED flashes Receiving data Status LED Red e Initialization phase A fault has occurred Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B Assembly and Installation Notes Connections and terminals at the bottom of ORA11B 4 4 4 4 1 Voltage supply of ORA11B 25 25 10 60 VDC 55 26 26 GND 9 Connections and terminals at the bottom of ORA11B Terminal Designation Description 25 10 60 VDC Voltage supply 26 GND Mass Manual MOVI PLC advanced Controller Remote Maintenance via ORA11B 64177AXX 17 5 Configuration Used components topology 5 Configuration 5 1 Used components topology Engineering PC ORA11B MOVI PLC advanced LAN Mii UR ARS ERE 4944 Ethernet cable N E for configuration b purposes 2 s Ethernet cable E Data transmission TETIT 8 M analog telephone line 64005AEN 5 2 Overview of assigned IP addresses NOTE Other IP addresses not listed as examples can be used as well Note that all
Download Pdf Manuals
Related Search
Related Contents
Guide de culture Alix POISSON H.264 Network DVR User Manual Entris - Strumenta MANUAL DE USUARIO DYNAVOICE SUB 8 取扱説明書 ① - SoftBank SELECTION Home Decorators Collection 1872510210 Instructions / Assembly MIPRO ACT-70T Cobra MT975 - User Manual KOHLER K-T16176-4-BN Installation Guide Copyright © All rights reserved.