USER MANUAL - Electrocomponents

image

Contents

1. Figure C 6 Return Loss measurements for Patton Model 580
2. of use installation the Model 580 is designed to be installed at the building entrance Both models use a multi stage Silicon Avalanche Diode circuit and will continue functioning while handling the appropriate IEC 801 5 surges applicable to their use see the tables in Appendix B Both the 570 and 580 will additionally protect against surges up to and exceeding 2kV 1kA in fail safe mode Models 570 and 580 support a wide range of balanced interfaces from RS 422 to 100Base T Highlights include a low insertion loss less than 0 4dB at 100MHz and minimal near end cross talk greater than 43 dB at all frequencies up to 100 MHz Grounding is accomplished via an external ground strap that provides a separate unit ground to chassis ground connection Warning This product will not provide complete protection should your equipment or building be subject to a direct lightning hit 3 0 INSTALLATION Patton s Model 570 8 580 surge protectors are easy to install and are designed to operate transparently to your network This section describes connection procedures for both models 3 1 PRODUCT APPLICATIONS Both Models 570 8 580 protect all eight pins on the modular RJ 45 Cat 5 interface and work in environments with data rates up to 100 Mbps The following descriptions will give you a general guideline for installing the units in your Cat 5 environment 3 1 1 POINT OF USE APPLICATION MODEL 570 The Model 570 is designed for installation o
3. 570 or 580 Exterior Wall Electrical Panel Model 570 or 580 Model 570 or 580 Model 580 Figure 2 A typical barrier application for the Patton Model 580 3 2 INSTALLATION PROCEDURES In order to operate as designed the Model 570 and 580 must be connected correctly to your Cat 5 network Please read all the instructions below and follow them carefully Connection of the Model 570 or 580 to an I O Port 1 Turn off equipment power and unplug disconnect the existing connection between the UTP cable and the equipment s I O port continued Install the Model 570 580 between the incoming UTP line and the protected equipment see Figure 3 below This installation requires a straight through Cat 5 patch cable with modular RJ 45 connectors supplied with unit Note It doesn t matter which end of the Model 570 580 plugs into which cable Cat 5 patch cable to protected equipment 6 inches or less Cat 5 input from network ZASObEZL INS 025 130900 an Gingsisyyed Connection to g Spre chassis ground Figure 3 Installation of Model 570 580 Surge Protectors 3 Locate a metal chassis ground on the equipment to be protected This is often a hex screw on a D shell or AUI connector Sometimes a metal back panel is attached by screws one of which can be used for chassis grounding If you cannot locate a chassis ground connection on your eguipment contact Patto
4. USER MANUAL MODEL 570 580 100Base T CAT 5 Surge Protectors PE PATTON Hs Electronics To Part 07M570 580 B SALES OFFICE Doc 074091UB Z Revised 2 16 96 Sone TECHNICAL SUPPORT 301 975 1007 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 570 580 components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification If this product fails or does not perform as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Te
5. chnical Service at 301 975 1007 Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 570 580 Technical Service hours 8AM to 5PM EST Monday through Friday 2 0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product This product has been thoroughly inspected and tested and is warranted for One Year parts and labor If any questions or problems arise during installation or use of this product please do not hesitate to contact Patton Electronics Customer Service at 301 975 1007 2 1 FEATURES Multi level surge protection Operation at Speeds up to 100 Mbps Optional 2 4 6 or 8 wire versions EIA TIA TSB 40A Category 5 Compliant e N E X T better than 43 dB at 100 MHz e Shunts surges directly to chassis ground Easy to install 2 2 DESCRIPTION Devices that connect to Category 5 cabling systems are routinely threatened by unwanted electrical energy lightning AC power induction ESD and more Higher speed devices such as those operating at 100 Mbps are especially vulnerable to the effects of these hazards which can include data loss and hardware damage The Patton Model 570 and 580 Series Surge Protectors provide effective surge protection for devices operating in Category 5 Cabling Systems The Model 570 is specifically designed for point
6. ices be tested and comply with all applicable International standards relating to the product type and category of use Electromagetic Compatibility Directive 89 336 EEC specifically addresses communication line surge protection devices since conformity to immunity standard EN50082 1 1992 is mandatory The EN50082 1 10992 standard incorporates International Organization for Standardization ISO publications 801 2 and 801 4 which describe Electrostatic Discharge and Electrical Fast Transient requirements ISO 801 5 describes Surge Immunity Requirements and is expected to be adopted as a mandatory requirement under EN50082 1 by the Technical Committee in 1996 Any protector sold into the international community must meet these standards This device has been tested and found to comply with these standards as evidenced by its CE mark IEC 801 5 Threat Levels as a Function of Class Class Sym Lines Coupling Mode Line GND Zs 42 Ohms 1 1 0 kV 24A 2 1 0 kV 24A 3 2 0 kV 48 A 4 n a n a 5 4 0 Kv 95A Wave 1 2 x 50 us Forms 1 2 x 50 us Figure B 1 IEC Threat Levels as a Function of Class Note All test results are for the Model 570 580 alone not including the standard 6 patch cable that is normally shipped with the unit APPENDIX B EIA TIA TSB 40A COMPLIANCE The Model 570 80 series surge protectors have been designed to conform to stringent EIA TIA TSB 40 standards as regui
7. n LAN eguipment in a typical office environment see Figure 1 below For best results the Model 570 should be connected as close as possible to the communication port of the device to be protected a 6 inch Category 5 patch cable is provided with the Model 570 Also the flat braided grounding wire on the Model 570 should be attached to the grounded metal frame of the device being protected Model 570 Model 570 Figure 1 A typical point of use application for the Patton Model 570 3 1 2 BARRIER APPLICATION MODEL 580 The Model 580 is a more robust protector than the Model 570 and is designed for use as a barrier protector on LAN eguipment in campus networks Applications include cable runs between buildings cable runs between floors on multi story structures and as a higher capacity replacement for the Model 570 a 6 inch Category 5 patch cable is provided with the Model 580 continued The Model 580 is also well suited for use in severe lightning areas heavy industrial environments and installations with heavy machinery in the direct vicinity of sensitive LAN eguipment and cabling Figure 2 below shows a typical application for the Model 580 For best results the braided grounding strap on the Model 580 should be attached to the grounded metal frame of the device being protected When installation is made ata barrier such as an external wall the braided strap should be connected to a nearby electrical ground Model
8. n Technical Support at 301 975 1000 to discuss an alternative grounding solution Connectthe braided ground strap directly to the chassis ground connection you have located see Figure 3 above The best way to make this connection is to attach the braided metal strap using a hex nut or screw on your device Caution Surge energy may run both directions on the ground strap To provide the best protection it is essential that the ground strap on the Model 570 580 be connected to the chassis ground of the protected device Do not engthen the ground strap of the Model 570 580 or connect to a ground other than chassis ground unless instructed to do so by Patton Technical Support Connection of the Model 580 at a Barrier Wall Bldg Entrance etc 1 Disconnect the UTP cable from the wall jack or patch panel jack Install the Model 580 between the UTP line and the jack This installation requires a straight through Cat 5 patch cable with modular RJ 45 connectors supplied with unit Note It doesn t matter which end of the Model 580 plugs into which cable Locate an electrical ground nearest the jack Often this will be on an electrical panel or sub panel If you cannot locate a nearby electrical ground contact Patton Technical Support at 301 975 1000 to discuss an alternative grounding solution Connect the braided ground strap directly to the electrical ground you have located The best way to make this connection is
9. red for all Category 5 connecting hardware These standards specify the capacitance and near end cross talk N E X T to insure proper operation of ALL connected eguipment Specific test results are shown in the tables on the following pages TSB 40A COMPLIANCE TESTING RESULTS TYPICAL NEAR END CROSSTALK MEASUREMENT SOURCE VICTIM PAIRS Figure C 1 N E X T measurements for Patton Model 570 SOURCE VICTIM PAIRS 51 0 45 0 Figure C 2 N E X T measurements for Patton Model 580 Note All test results are for the Model 570 580 alone not including the standard 6 patch cable that is normally shipped with the unit APPENDIX B continued TSB 40A COMPLIANCE TESTING RESULTS TYPICAL ATTENUATION MEASUREMENT FREQ PINS 1 2 PINS 3 6 PINS 4 5 Figure C 3 Attenuation measurements for Patton Model 570 25 62 5 Figure C 4 Attenuation measurements for Patton Model 580 10 APPENDIX B continued TSB 40A COMPLIANCE TESTING RESULTS TYPICAL RETURN LOSS MEASUREMENT FREG PINS 1 2 PINS 3 6 PINS 4 5 PINS 7 8 MHz dB dB dB dB 1 27 3 27 6 28 0 aj 420 4oa 94 40 4 23 10 41 4 16 33 4 35 3 23 20 37 0 284 HB 33 4 23 25 14 240 250 L 109 198 218 Figure C 5 Return Loss measurements for Patton Model 570
10. to attach the braided metal strap to a metal panel or wallplate screw using a hex nut or screw Caution Surge energy may run both directions on the ground strap To provide the best protection it is essential that the ground strap on the Model 580 be connected to an electrical ground APPENDIX A SPECIFICATIONS Environment Category 5 Interfaces that utilize the RJ 45 connector including RS 422 423 10Base T Token Ring Fast Ethernet 100Base T and ATM Connectors RJ 45 Female Response Time Clamped to 13 V after 0 1 us Characteristic Impedance 100 Ohms NEXT Loss Model 570 worst pair Better than 46 dB at 100 MHz Model 580 worst pair Better than 43 dB at 100 MHz Surge Clamp Voltage Model 570 13 V max with 1 KV Input Model 580 15 V max with 2 KV Input Surge Rating IEC 801 5 Standard Level DC Clamp Voltage Common Mode to Gnd each line 7 5 V 50 mA Differential mode per pair 8 1 V O 50 mA Insertion Loss Less than 0 4 dB at 100 MHz including connector Return Loss Better than 14 dB Group Delay None 1 MHz to 100 MHz Series Resistance Less than 400 milliohms Grounding External ground strap provides separate unit ground to chassis ground contact Dimensions 2 25 x 1 69 x 75 APPENDIX B INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC COMPLIANCE Meets IEC standards 801 2 801 4 and 801 5 CE Mark Effective January 1996 the European Economic Community will reguire that all electronic dev