1. an SMS message should not be sent A following C means that the event is to be reported to the monitoring station while means no report 19 You can move around the cursor with the help of the right and left buttons and you can alternate between characters and with any number button 11 2 3 SMS texts An SMS message with maximum 20 characters can be set to each event The module will send this SMS when the event has occurred With the help of up and down buttons similarly to the above mentioned method you can choose an event and create an assigned SMS message in the bottom line of the display You shall move the cursor with the help of the left and right buttons By pressing the number buttons repeatedly you will see the characters as follow Push button 0 0 A Push button 1 1 amp lt gt _ you will have the space character after pushing it the first time Push button 2 2AaBbCc Push button 3 3DdEeFf Push button 4 4GgHhli Push button 5 5JjJKkLI Push button 6 6MmNnOo Push button 7 7PpQqRrSs Push button 8 8TtUuVv Push button 9 JWwXxYyZz As it was shown earlier it is possible to name each user and zone Certain events can be assigned to certain users E g in case of the events Arming and Disarming it might be important to know which user has armed or disarmed the system Similarly in case of alarm or sabotage it might be necessary to find out which zone has caused it Inse
2. the user will not be able to reach the Zone memory menu item Zone Bypass Is the user authorised to bypass certain zones If this authority is not allowed the user will not be able to reach Zone Bypass menu Clear smoke detectors Is the user authorised to reset the smoke detectors If this authority is not allowed the user will not be able to reach Clear smoke detectors menu Arming through the telephone Is the user authorised to arm the partition or partitions that are allowed for him her remotely through a telephone with the help of his her own user code Disarming through the telephone Is the user authorised to deactivate the partition or partitions that are allowed for him her remotely through a telephone with the help of his her own user code 15 15 16 5 7 8 9 Relay control through the telephone Is the user authorised to control relay outputs remotely through a telephone with the help of his her own user code Recording voice messages Is the user authorised to record the 12 voice messages and listen them back Error list In this menu item you can list all valid errors These kinds of errors are e g the signals of zone sabotages keypad sabotage accumulator s fault etc The list changes dynamically that is if an error has been corrected that error will disappear from the list this way the installer can check the changes while trying to repair the e
3. RELAY SENSOR IN1 IN12 1 SIGNALLING DEVICE TAMPER NC TRANSFORMER 220V AC 29
4. device OUT2 12V 1 0A programmable Make sure to avoid short circuit and to the maximum current load of each output The ON state of the outputs is signalled by the red signals of the LEDs there The outputs are protected against overcurrent If the output notices overcurrent in ON state it turnes off the outgoing 12V voltage and the blinking of the belonging red LED signals the overcurrent state Additionally the module contains 3 pieces of relays with independent outputs NO COM NC that can be used freely Maximal load of relays 12V 5 0A The relays can assigned to events or can be controlled through a telephone see 11 6 3 1 11 6 3 4 3 3 1 Installation of external and internal signalling devices Outputs OUT1 OUT2 be programmed according to the following method e wiring 1 in normal state and 12V in case of an alarm e wiring 2 12V charge of siren s battery in normal state and OV in case of an alarm e wiring 3 permanent 12V output In this case eg OUT1 provides the continuous power supply of the siren and OUT2 starts signalling devices in case of an event It is possible to connect further signalling devices by using the outputs of the relay You can set starting and stopping events or timings to these 3 4 Installation of the keypad The GSM UTLIMATE module is capable of accepting various keypads For this program version SATEL CA 64 LCD has been adapted You have to connect the keypad to the
5. enter data e g in case of entering SMS messages they move the cursor right or left In this case you can leave this menu by pushing or buttons A further meaning of push button is accepting entered data while push button means cancel e g in the menu Changing user In user s menus if you do not press any push buttons for a certain time a countdown starts on the keypad After this time has expired the keypad leaves the menu and returns to the date screen During the time of countdown you can stop the procedure by pushing any button and you can go on doing what you did in the menu Maximum 8 keypads can be connected to the system with different keypad ID number however at the same time you can enter the menu on only one of them Countdown and automatic menu exit is actually a prevention against forgetting a keypad in the menu blocking the others The function of this automatic menu exit is disabled in certain installer menus where longer monitoring is necessary e g monitoring inputs M1 M11 The description of the keypad menu 1 Arming This menu item only appears if the user who has entered the menu by using his her code is authorised to arm some partitions and that certain partition is not armed at that time see Rights section M4 1 3 In the menu the user can arm the authorised partition or partitions by pressing push button M1 1 Full arm Both partitions are activated at the same ti
6. for installation and finding errors M11 14 1 Zone test This menu shows the actual resistor value that can be measured on the zones listing the 12 zones and inputs A and B next to each other The meanings are as follows 0 short circuit 1 value corresponding to 1kOhm 2 value corresponding to 2kOhm open circuit M11 14 2 Output tests The outputs can be turned on and off so that the devices on the outputs can be checked with the help of the following buttons 1 RELE1 off on 2 RELE2 off on 3 RELE3 off on 4 OUT off on 5 2 off on 0 refers to OFF and 1 refers to ON state In case of and OUT2 exclamation mark signals if there is overcurrent on the output terminal When exiting the menu the outputs restore their previous state according to their settings and operation M11 14 3 Power checking The power of the accumulator and the existence of AC power can be checked If the accumulator is in charge before you enter the menu about one minute is needed until the displayed voltage level restores to the actual power of the accumulator from the temporarily higher voltage that is caused by charging M11 14 4 Analogue input Reserved for future developments M11 14 5 Event spy Here the latest event can continuously be monitored In case of the occurrence of a newer event the display gets automatically refreshed too M11 14 6 GSM power check At installation try to
7. module as follows ULTIMATE CA 64 LCD CKM gt CKM DTM gt DTM KPD gt KPD L gt The maximum number of keypads can be 8 pieces You have to address the keypad as follows In powered down state close the CKM and DTM connectors on the keypad in a way that the relating cables of the alarm system should not be connected After turning the power supply on again the keypad offers the requested address 0 7 There cannot be two keypads with the same address After turning off the device again can the keypad be installed according to the above mentioned wiring description wiring the keypads parallel 3 5 Installation of serial connection Standard serial port to PC connection There is a possibility to program the module by PC control all parameters or change the system program firmware 3 6 GSM antenna Radio antenna SIM card The enclosed antenna has to be led through the 214 hole drilled on the top of the box Any kind of SIM card can be inserted into the SIM case where call and SMS functions are allowed IMPORTANT NOTE The request for pin code has to be disabled before you insert the SIM card into the module Note With the help of a supplementary PC program UltimateRemoter exe the module can also be reached remotely through a mobile phone in data call mode the settings can be checked modified the events can be read etc In case of certain SIM cards and services the service provider does not enable accep
8. place the aerial in a way that the telephone can measure an as good GSM power as possible It can be checked continuously with a few second delay The value of power can be read on a scale of 0 31 26 11 15 Program version The GSM Ultimate internal program version can be checked in this menu It might be necessary to know at the replacement of newer program versions with extended functions M11 16 Radio devices Here you can do the assignment teaching and setting of radio devices see below M 11 16 1 Delete RF devices It deletes all radio devices After use all radio devices have to be reassigned M11 16 2 RF sensor programming A Maximum two radio devices can be assigned to each zone The first primary device of each zone can be assigned here On the bottom line of the keypad you can see the state of primary radio device for the 12 zones 7 signals the zones that have not been assigned You can choose the zone to be assigned by the right or left arrows Then push button 1 to assign On the keypad a question will appear whether you really wish to reassign the primary device belonging to the zone In case of yes you will see 2 on the bottom line of the keypad in the place of the zone signifying that the module is ready to learn the device We shall send signals from the radio device twice to be assigned Move in front of the infra sensor open close the contact of the magnet sensor or cause a sabotage signal b
9. sabotage With alternative impulses Continuous 2K normal state Short circuit impulse arming 1K impulse disarming circuit opening sabotage With one kind of impulse Continuous 2K normal state 1K impulse arming disarming short circuit or circuit opening sabotage M11 6 Outputs The module has two 12V voltage output terminals for operating the signalling devices smoke detector etc OUT1 OUT2 and pieces of independent relay output terminals for operating external devices RELE1 RELE2 RELE3 The parameters of these output terminals can be set in the below mentioned menu items M11 6 1 1 OUT1 connection You can choose from the below mentioned installation methods to install OUT1 output YYY VVVV WV Siren 12V In inactive state there is no voltage on the output terminal At alarm it releases 12V for operating the signalling devices Siren 0V In inactive state it releases 12V and charges e g the internal accumulator of the siren with it At alarm the voltage is set to 0 and the siren is armed Fix 12V A continuous 12 is released independently from the state of the alarm process You can install OUT2 the same way M11 6 1 2 OUT1 Siren delay The length of time can be set between the occurrence of an alarm event and sound of the siren that is connected to OUT1 output This time can be set between 0 255 seconds in seconds 11 6 1 3 OUTI Siren time max The maximum time of the siren caused
10. since the last activation Characters next to each other signal the change in the zone s state The meanings of the certain characters are as follows gt amp amp the zone has stayed in inactive state from the beginning to the end gt the zone has tilted but has not caused an alarm e g it signalled during the time of leave or in disarmed state gt the zone has caused an alarm gt b the zone is bypassed Zone bypass see section M9 This menu can only be reached by authorised users see section M4 Zone bypass Authorised users can bypass certain zones in this menu Characters next to each other indicates the state of certain zones gt signals that the given zone is active gt b signals that monitoring of the zone has been disabled bypass With the help of right left buttons the cursor can be moved around the zones and with the help of any number button the state of the zone can be changed back and forth to signal 16 M10 11 This menu item can only be reached by authorised users see section 4 Clear smoke detectors This menu disconnects power supply received from OUT2 output from the smoke detectors for a few seconds and by doing so it resets them See section Connecting smoke detectors Installer menu This menu item can only be reached by the installer code here all necessary settings can be fulfilled at installation M11 1 Settin
11. 2 3 11 2 4 11 3 11 4 11 5 11 6 11 6 1 1 11 6 1 2 11 6 1 3 11 6 2 11 11 11 11 N WwW WwW Ww A 11 7 11 8 11 9 11 10 11 11 11 12 11 13 11 13 1 11 13 2 11 13 3 11 13 3 1 12 gt ON ALARM 11 13 3 2 gt QUICKARM M11 13 3 3 gt ZONE MONITORING M11 13 3 4 gt TESTS M11 14 gt ZONE TEST M11 14 1 gt OUTPUT TESTS M11 14 2 gt POWER CHECK M11 14 3 gt ANALOGUE INPUT M11 14 4 gt EVENT SPY M11 14 5 gt GSM POWER CHECK M11 14 6 gt PROGRAM VERSION M11 15 gt RADIO DEVICES M11 16 gt DELETE RF DEVICES M11 16 1 gt RF SENSOR PROGRAMMING A M11 16 2 gt RF SENSOR PROGRAMMING M11 16 3 gt RF REMOTE KEY PROGRAMMING M11 16 4 gt RF KEY ASSIGN M11 16 5 gt CLEAR ALL ALARM M11 17 11 The use of LCD keypad On the keypad you can see the date and time in still state From here you can enter the menu by entering a user code For this enter the code with 4 or 6 digit on the keypad then press You can move around the menu items with the up and down buttons By pushing the right arrow or you can enter a menu item or a submenu and by pushing the left arrow or you can exit a menu item come one level up in the menu structure There are certain submenus where the left and right buttons are necessary to
12. ER SETTINGS gt 001 gt CODE gt NAME gt RIGHTS gt 002 gt 012 gt ERRORLIST gt TIME SETTINGS gt EVENTLIST gt ZONE MEMORY gt ZONE BYPASS gt CLEAR SMOKEDETECTOR gt STOP SOUNDER gt INSTALLER MENU gt ZONES gt 201 gt ZONE NAME gt CONNECTION gt PARTITION SET gt ZONE SENSITIVITY gt ENTRY DELAY gt LEAVE DELAY gt INTELLI ZONE gt SILENT LOUD gt TRACKER NORMAL gt 7 TIME gt NIGHT SETTINGS gt 202 gt 212 gt EVENTS gt CONTACT ID CODE gt NOTIFICATIONS gt SMS TEXTS gt VOICE MESSAGES gt PHONE NUMBERS gt CTID USER ID gt A B INPUTS gt OUTPUTS gt OUT1 OUTPUT gt OUT1 CONNECTION gt SIREN DELAY gt SIREN TIME MAX gt OUT2 OUTPUT gt OUT1 amp 2 SETTING gt RELE1 OUTPUT gt ACTIVAT EVENT gt DEACT EVENT gt START DELAY gt TIME MAX gt RELE2 OUTPUT gt RELE3 OUTPUT ALARM TIME MAX ZONE ALARM MAX AUTO ARM TEST EVENT TIME TEST EVENT FREQUENCY NIGHT DELAY LCD KEYPAD gt BACKLIGHT gt DOORBELL gt SETTINGS gt NIGHT MUTE 1 1 1 1 2 1 3 1 4 2 4 4 1 4 2 4 3 5 6 M7 M8 M9 M10 M11 MI E1 M11 11 11 11 11 11 11 11 11 11 11 1 222 43 4 25 6 8 19 10 11 2 M11 2 1 M11 2 2 11
13. GSM ULTIMATE Installation and User Manual for module version 1 30 Table of contents Technical information The main characteristics of the device 3 How to install the panel 3 1 Installation of the sensors 3 2 Installation of arming disarming circuit 3 2 1 installation method 1 controlled by a switch or a relay 3 2 2 installation method no 2 controlled by two kinds of short circuit impulses 3 2 3 installation method no 3 controlled by one kind of short circuit impulse 3 3 Installation of the outputs 3 3 1 Installation of external and internal signalling devices 3 4 Installation of the keypad 3 5 Installation of serial connection 3 6 GSM antenna Radio antenna SIM card 3 7 Installation of power supply 3 8 Installation of the accumulator 3 9 Installation of smoke detectors 4 The meaning of the panel s LED signals 5 The LCD keypad 5 1 Information that can be read on the keypad 5 2 How to program the module through the keypad 6 Deleting the central memory 7 Recording voice messages 8 The use of radio devices 9 Functions that can be reached through a telephone 10 The menu structure of the LCD keypad 11 The use of LCD keypad Ne M1 M11 The description of the keypad menu General wiring diagram 1 Technical information Power supply Average power consumption Operational temperature Size Accessories Proposed external elements Inputs Outputs Progr
14. am connector GSM transmitting device Charging of accumulator 16V 18V 50Hz AC 200mA 0 60 C 202x124 mm GSM antenna 900 1800 MHZ cable Plastic fixing mounts 4 pcs Accumulator cable 1k Ohm resistor 40 pcs Transformer 16V 40 VA Accumulator 12V 7Ah Keypad programmer SATEL CA 64 LCD maximum 8 pcs 12 zones maximum 24 sensors Installation methods can be chosen by each zone e Short circuit activated e Activated by circuit opening e DEOL closed by resistor monitoring sabotage 1 or2 sensors zone 2 inputs A B for activation or deactivation with DEOL closure 1 analogue voltage input reserved Keypad power supply KPD 12V 0 5A DC Sensor power supply 12 V 12V 0 5A DC internal signalling device 12V 1A DC OUT2 external signalling device 12V 1A DC RELAY independent NO NC RELA Y2 independent NO NC RELAY3 independent NO NC 5 232 serial connector for PC programming SONY ERICSSON 47 5 industrial GSM module Cyclical voltage controlled charge max 800mA charging current 2 The main characteristics of the device 12 24 zone multifunctional alarm system with built in GSM communicator e handling two independent partitions that can also be armed disarmed from an independent external device e storing 576 events with date and time e LCD keypad with transparent menu system easy and quick to program e Telephone calls with recordable voice messages 12
15. by the alarm process can be set This time can be set between 1 25 minutes 22 11 6 2 OUT1 amp 2 SETTING If Sabotage audible option here is not enabled the zone sabotage event causes a sound signal only in armed state If this option is enabled zone sabotage causes a sound signal in deactivated state as well M11 6 3 1 RELE1 Activating event The occurrence of different events turnes the relay on and off taking the later mentioned timings into consideration Entering the menu the list of all kinds of events is to be seen You can move around them with the help of the up and down buttons You can alternate between Y and N by pressing any number button that is whether the event shall turn the relay on or not More events can be chosen and the occurrence of any of them can turn on relay In the event list number 0 means control through the telephone You have the possibility to decide here whether the relay could be controlled remotely through the telephone or not M11 6 3 2 RELE1 Deactivating event Similarly to the above menu you can specify the events the occurrence of which should cause the relay to be turned off The occurrence of any chosen event turns the relay off In the list of events number 0 means control through the telephone You have the possibility to decide here whether the relay could be deactivated remotely through the telephone or not 11 6 3 3 RELE1 start delay It can be
16. d in the last but one minute it signals with a short beep So the user has time to exit Armed tracker zones to disarm the device to return to Starting zone which restarts timing M11 2 Setting the parameters of events You can set the below mentioned characteristics to each zone M11 2 1 CONTACT ID code Here three digit event code can be set that is necessary for CONTACT ID signal The panel contains the standard event codes by default however these can be changed if necessary You can move around the different events with the help of the up and down buttons The code of the chosen event can be entered on the keyboard The hexadecimal numbers of A B C D E F can be revealed by pressing buttons 2 and 3 repeatedly You can move the cursor among the digits with the help of the right and left arrows M11 2 2 Notifications Similarly to the above mentioned menu item choose the event whose characteristics are to be changed with the help of the up and down buttons You will see the following structure in the second line of the display 8 ore g P S C The four characters that follow P refer to telephone numbers 1 4 Where you can see that phone number will be called in case of the event occurs however the number will not be called if you see The four characters that follow S also refer to telephone numbers 1 4 but they mean sending an SMS message an SMS message should be sent
17. disarmed then armed again the zone will be allowed again which means that it can forward alarms however only as it is maximally allowed Value zero means that the number of alarms is not limited M11 9 Auto arm It can be set that if all zones are still for a given time 1 255 hours the panel gets armed automatically M11 10 Test event time The time hour minute can be set when the module shall send the test report M11 11 Test event frequency The frequency of test reports can be set that is in how many days interval shall the module send a test report Value zero means that the module does not send a test report M11 12 Night timing The parameter can be set between and 25 minutes for further information see section M11 1 11 Night setting M11 13 LCD Keypad M11 13 1 Backlight On the keypad we distinguish between LCD keypad backround lighting and push button ligting You can choose from the below mentioned combinations to set them LCD 0 1 In inactive mode both LCD and push button lightings are turned off By pressing any button they start lighting in complete intensity After one minute they get back to normal LCD 1 Key Aut In inactive mode LCD lights in half intensity and push button background lighting is turned off By pressing any button both of them start lighting in complete intensity After one minute they get back to normal LCD On Key Aut LCD is always lit and pu
18. en 1 and 255 minutes and the panel is in disarmed state then if the zone detector does not tilt in the given time a zone cover event is generated If the parameter is zero the function is disabled 18 M11 1 11 Night You can set how the zone should operate in case of night setting Possible options Always armed at night it will behave according to the day set with the set delays etc E g if it is an entering zone then it will go on behaving as an entering zone at night too Armed tracker These zones normally work the same way as Always armed zones however if a Starting zone signals it initiates a timing section M11 12 night timing During timing the module disregards the signals of Armed follow zones Disarmed In night armed state the module disregards these zones Starting zone This zone corresponds to Disarmed zone however due to its signal night timing starts see M11 12 for armed tracker zones Note At night arming night timing also starts to operate the same way it would have entered a Starting zone that is for the set time the module disregards the signals of tracker zones leaving time for the user to exit Armed tracker zones Note In the last two minutes before the expiry of night timing at the signal of any Armed tracker zone the keypad indicates that timing expires by beep signal In the last minute it signals with a long an
19. g zones 701 First the zone needs to be chosen the data of which you wish to modify 2 712 If you already assigned a name to the zone earlier this name will also appear next to the number You can modify the following data to each zone M11 1 1 Zone name You can enter a zone name with maximum 10 characters You can get the letters by pushing the number buttons repeatedly similarly to writing an SMS on the mobile phone The only difference is that the cursor does not automatically move forward but by moving the right left buttons This name can appear later in the SMS messages being sent at certain events e g alarm sabotage see section M11 2 3 M11 1 2 Connection mode Three different installation methods can be chosen for each zone gt armed by short circuit gt armed by circuit opening gt DEOL inactive state 2k alarm short circuit or circuit opening sabotage gt Radio zone only in case of Ultimate with radio receiver If the zone is chosen to be radio zone the module disregards the state of the given physical input and considers only the signals of radio devices Note Within a system you can use radio and wired devices however one zone can be chosen to be only either of them radio or wired Teaching of the radio devices is described in section 11 16 RF devices M11 1 3 Partition set You have the option to choose which partition this zone belongs to gt Partition 1 amp 2 the zone belo
20. hort circuit impulse that comes in through another independent contact It is e g the receiver part of RF Remote Control Subsystem module where as a result of the activating push button the relay of it closes for a short time and as a result of the deactivating push button this procedure happens with another relay If a situation like this happens connect the input according to the wiring below You have to choose wiring mode 2 Impulse 2kind at settings see 11 5 eae dl ual Disarm Activate Continuous 2k Ohm Normal state Short circuit impulse Arm 1k Ohm impulse Disarm Open Sabotage 3 2 3 installation method no 3 controlled by one kind of short circuit impulse In the third installation method we arm and disarm the module with the same short circuit impulse that is the module gets armed as a result of one impulse and gets disarmed as a result of another While you are setting the module you have to choose wiring mode 3 Impulse 1 kind see M 11 5 Continuous 2k Ohm Normal state 1k Ohm impulse arm disarm Short circuit or open sabotage 3 3 Installation of the outputs The alarm system has 4 pieces of voltage outputs two of them are fix and two of them can be programmed Power supply of keypad KPD 12V 0 5A fix Power supply of sensors 12 V 12V 0 5A fix Internal signaling device 12V 1 0A programmable External signaling
21. ing in a way that the old code remains unchanged Note The system does not accept 000000 code this code is reserved for delete see section M4 2 M4 User settings This menu item can only be reached by installers entering the menu by using installer code or by users who have been given authority to by the installer There is a possibility to modify users options in this menu First you have to choose the user whose options you wish to modify F01 F12 If you entered and stored a name to the given user before then it will also appear next to the number You can modify the following details of the users individually M4 1 Name You can enter a name with maximum 10 characters You can get the letters by pushing the number buttons repeatedly similarly to writing an SMS on the mobile phone The only difference is that the cursor does not automatically move forward but by moving the right left buttons This name can appear later in the SMS messages being sent at certain events e g opening closing see section M11 2 3 M4 2 Code Here a code with 4 or 6 digit is set that will later be the given user s code Entering 000000 deletes the user code 4 3 Rights Here you can allow or ban the following rights for the user You can move around the rights with the up down buttons and you can change whether you allow the user the certain right by pressing any number button This is signalled by Y allowed or N banned 1 Part
22. ition 1 Is the user authorised to partition 1 14 10 11 12 13 14 Partition 2 Is the user authorised to partition 2 Arming Is the user authorised to arm the above partition or partitions Disarming Is the user authorised to disarm the above partition or partitions Change user code Is the user authorised to change his her own user code If this right is not allowed Change user code menu item will not appear when the user enters the menu with his code Editing users Is the user authorised to change all users details authorities and to set new users You should allow this authority to that possibly one person who will maintain users options in the future and set potential new users If this authority is not allowed the user entering the menu with his her own user code will not see the menu item Users Error list Is the user authorised to see error lists If this authority is not allowed the user will not be able to reach the Error list menu item Time setting Is the user authorised to set the time on the panel If this authority is not allowed the user will not be able to reach the Time setting menu item Event list Is the user authorised to see the event list If this authority is not allowed the user will not be able to reach the Event list menu item Zone memory Is the user authorised to see the changes of zones states If this authority is not allowed
23. me if the user has the authority M1 2 Arm partition 1 Only partition 1 is activated if the user has the authority M1 3 Arm partition 2 Only partition 2 is activated if the user has the authority 13 M1 4 Night arm In case of night arming both partitions get activated at the same time In this case zones will behave as described in section M 1 10 Night setting The user should have authority for both partitions Note For further arming methods see M11 13 3 3 QUICKARM M2 Disarming This menu item only appears if the user who has entered the menu by using his her code is authorised to disarm some partitions and that certain partition is armed at that time see Rights section 4 1 3 If both partitions are armed and the user is authorised to disarm both partitions it is possible to disarm either partition 1 or partition 2 or both of them in the appearing menu by entering user identification code and In case of night arm it is not possible to disarm by partitions In disarmed state in case of an alarm happening as a result of 24 hour zone or sabotage event the system can be silenced by entering user code and and pressing DEACTIVATE SIGNALLING DEVICES appearing on the LCD keypad Change user code In this menu the user who has entered the menu by using his her code can change his her own user code You can enter your new 4 or 6 digit identifier code and validate it by pressing You can exit the menu by press
24. n be avoided e g a false alarm that is caused by the convection from starting a gas convector Here the time limit 1 25 minutes can be set and during this time the detector shall tilt at least twice for the alarm to be started In case this parameter is zero this function is disabled and each signal causes alarm M11 1 8 Silent Audible zones All zones are by default set to be audible which means that the signalling devices start operating in case of an alarm In case of silent zone if the alarm was caused by this zone the signalling devices do not start operating M11 1 9 Tracker Normal When a zone is set to be tracker and is violated one of the two following cases may occur gt In armed state if the violator enters the tracker zone through another entry delay zone then the tracker zone takes up the remaining delay of the entry delay zone gt If there is no violation of any delay zone before the violation of tracker zone the tracker zone starts the alarm immediately according to its own entry delay Example delay of corridor zone is e g 30 seconds The keypad is in the living room the living room zone should be signed to be tracker zone and entry delay should be zero In this case entering the living room through the corridor the living room will also take up delay But entering the living room not through the corridor will cause immediate alarm M11 1 10 Zone cover time If the zone cover time is set to be betwe
25. ne numbers You can specify maximum 4 telephone numbers to be used for the alarm and the method of acknowledgement for each and also the maximum 2 telephone numbers of the monitoring station You can find the following menus here 1 Telephone number Acknowledgement of 1 telephone number 2 Telephone number Acknowledgement of 2 telephone number 3 telephone number Acknowledgement of 3 telephone number 4 telephone number Acknowledgement of 4 telephone number 1 telephone number of monitoring station 2 telephone number of monitoring station VVVVVVVVVV You shall set the telephone numbers consistently the module accepts only numbers The following options exist in case of acknowledgement gt acknowledgement gt acknowledgement gt acknowledgement Stop In the first case when an acknowledgement is not requested at the alarm call the module plays the voice message twice after a short siren signal then automatically disconnects the line It considers the telephone call to be successful if the call has been accepted In the second case acknowledgement the module gives out a siren signal then waits for the customer to press on his her telephone If is not pressed that is the call is not acknowledged the module hangs up the line within a few seconds This case the call is considered to have been unsuccessful therefore the module will try to call this number again in the next cycle If is p
26. ngs to both partitions E g in case of two adjoining shops where one partition refers to one of the shops and the other partition to the other shop such a common zone means commonly used rooms e g toilet where both owners can enter separately even if the other shop s partition is already armed gt Partition 1 The zone belongs only to partition 1 gt Partition 2 The zone belongs only to partition 2 gt 24 hour zone It is always active independently from the armed or disarmed state of partitions The system is not partitioned in default each zone is in Partition 1 amp 2 17 11 1 4 Zone sensitivity You can set the time that the module does not take note of if the change is shorter than the determined time on the given zone input This interval can be set in tenth seconds steps between 0 25 5 seconds limits and they can be set to each zone separately M11 1 5 Entry delay Entry delay can be set to each zone between 0 255 seconds The violator has this time to disarm the system after the violation of this zone otherwise the procedure of alarm will start M11 1 6 Leave delay Each zone s exit delay can be set between 0 255 seconds individually The user has this time to leave the zone after arming the system M11 1 7 Intelligent zone In case of intelligent zone the process of alarm will not be started unless there are at least two signals in a given time interval By this the most frequent false alarms ca
27. nt if any error has occurred in the system e g error of battery error of GSM field strength sabotage of zone etc ALARM alarm is in process ARMED system is armed either partition A or B or both of them 1 32 partition A is armed 33 64 partition B is armed ERROR error signal of system you can find the description of error in the ERROR LIST menu Note To show the state of zones on the keypad see 11 13 3 4 Zone monitoring 5 2 How to program the module through the keypad You have to start programming the module by entering the installer code see 11 The use of the keypad The default installer code of ULTIMATE module is 1111 Change it after entry Then according to the menu system described in chapter 10 take the possibilities of setting in order and enter or choose the appropriate parameters To find further information on the use of LCD keypad see sections 70 The menu structure of LCD keypad and 11 The use of LCD keypad 6 Deleting the central memory If the installer has not written down or lost the changed code entering the system can only take place if the whole central memory is deleted You can do the complete delete as follows e Power down the module Remove all the cables and resistors from all input terminals Connect 1k Ohm resistor between input B and the GND Keep the push button of the panel pressed and this way turn the power supply on In 10 seconds alternate blinking can be seen when you can
28. on 3 continuously both partitions can be armed at the same time Complete arming e Pressing push button 4 continuously corresponds to night arming M11 13 3 3 Zone monitoring Enabling this function it is possible to monitor zones state continuously when the menu is not shown on the keypad When date time is shown If this option is enabled zone appearance can be chosen as follows By pressing push button 7 continuously for 5 6 seconds zone monitoring gest turned off on the keypad pressing push button 8 continuously a character appears corresponding to each zone on the bottom line of the keypad These characters have the meaning 4 zone is inactive 1 12 zone signals in case of radio zone the sensor s battery belonging to the zone is weak This kind of indication method stays active as long as it is turned off by pressing push button 7 By pressing push button 9 continuously for 5 6 seconds the violated zones appear on the bottom line of the keypad according to their names In case there are more violated zones the keypad shows them alternatively one after the other continuously Next to the zone in case of radio zone the letter V in the last character position signals that the sensor s battery belonging to the zone is weak This kind of indication method stays active until it is turned off by pressing push button 7 25 M11 14 Tests The below mentioned menu items provide help
29. owers under 11 V it generates a report of error towards the keypad and the monitoring station The charging current is 800 mA with the help of it a completely flat accumulator can be recharged within 10 hours 3 9 Installation of smoke detectors The installation of smoke detectors is identical with the installation of zones However there is a difference namely that the power supply of the smoke detector should not be taken from the fix 12V output but from output OUT 2 In this case the installation of OUT2 should be set to fix 12V See M11 6 1 1 referring to OUT2 After the signal you can reset the smoke detector in menu DELETING SMOKE DETECTOR see M10 4 The meaning of the panel s LED signals POWER the system is under power supply GSM NET GSM connection is all right field strength is appropriate GPRS NET connected to GPRS system ALARM alarm is in process ARMED system is armed either partition A or B or both of them ERROR communicational error The LED belonging to the outputs and relays has a continuous light if it is turned on The blinking of LED at power outputs signals overcurrent 5 LCD Keypad 5 1 Information that can be read on the keypad You can see the state of the alarm system on the LCD display which contains the following main information e Armed or disarmed state the Armed LED blinks or not and which partition is armed e Blinking of error LED signals beside the reports of error se
30. pieces of 5 second long messages Sending SMS messages with user and zone identification e g OPENING THE SHOP THOMAS Signalling to monitoring station CONTACT ID Differentiating 47 kinds of events 4 telephone numbers for the alarm calls and SMS 2 telephone numbers for Contact ID signals Handling 12 users 12 user codes with 4 6 digits Arming disarming by telephone enquiry on state relay control and voice recording e Free Ultimate Remoter program for PC for the functions as follows e Programming the module on serial port or by remote download e Complete remote diagnostics power supply battery voltage overcurrent monitoring control of zones and outputs inspection of event memory 3 How to install the panel 3 1 Installation of the sensors 3 different installation methods can be used they can be set by each zone see 11 1 2 e activated by short circuit e activated by circuit opening e input closed by resistor DEOL At DEOL types of installation connect the sensors to inputs IN12 with the enclosed Ohm resistors according to the drawing below eee Contact alarm According to the above application the input can have the states as follows 1k Ohm inactive state 2k Ohm alarm Open sabotage Short sabotage In case 12 sensors are not enough there is the possibility to double the sensors within a zone according to the method as follo
31. ressed during the time of siren siren is ceased and the voice message is played twice and in a few seconds the line will hang up This case the call is considered to be successful and no further calls will be directed to this telephone number because of this event The third case acknowledgement Stop coincides with the previous case with an addition that during or after the voice message if is pressed the module stops reporting the event No further telephone calls SMS messages and calls to the monitoring station will be directed to or sent because of this event However if other events have happened notification about them will start independently M11 4 CTID user ID Here you can specify the four digit customer identification that is necessary for the Contact ID signal The ID can contain digits as well as the A B C D E and F letters You shall specify it the same way it was described in Contact ID event code see section 11 2 1 21 11 5 B inputs Inputs A and B can be used to connect external code switch hopping code remote controls or any other devices that are used for arming or disarming Input A refers to partition 1 while input B to partition 2 You can choose from the below mentioned methods VVVVVVVVVVVV VV V Only with a keypad This time the module does not monitor inputs A and B With a switch 1K 2K Continuous 1K armed Continuous 2K disarmed Short circuit or circuit opening
32. rrors Next to Error list you can see the number of error events in brackets After eliminate some of the reasons of the errors the signal does not cease immediately E g if you can read Accumulator missing and connect the accumulator the signal will go on being there for maximal 10 minutes This happens because of the cycle of charge and voltage control Other signals e g zone sabotage immediately disappear after the error being repaired This menu can only be reached by authorised users see section M4 Time setting Here you can set the actual date and time Entering the menu you can see yy hh dd hh mm where you can enter the appropriate numbers instead of the letters After entering the numbers you can store the new data by pressing push button You can exit the menu during the time of entering the numbers by pressing push button and in this case the date and time set earlier will stay unchanged This menu can only be reached by authorised users see section M4 Event list You can see the last 576 events in groups of 16 That is first you have to choose which 16 events you are interested in in chronological order Events 001 016 are the most recent 001 of which shows the most recent event of them all The higher the serial number is the oldest the event is This menu item can only be reached by authorised users see section M4 Zone memory In this menu you can control the changes in zones
33. rting into the SMS text the module will replace it with name of the correspondent zone or user when sending this SMS message E g the SMS written Opening the shop The SMS sent Opening the shop Thomas The length of the name does not have to be calculated into the maximum 20 characters only This means that the sent SMS message where a name is substituted can be longer than 20 characters The module decides from the event whether the should be replaced with a zone name or a username The other character that can be substituted for is This can be replaced by the number of the user or zone User nr 13 means the installer while zone 0 means the LCD display e g in case of sabotage E g SMS written Opening the shop user SMS sent Opening the shop 3 user If the SMS text was left completely empty space until the end the module will send its own originally set short SMS messages in English Actually the original messages correspond to the name of the event which in case of SMS texts setting can be read on the top line of the LCD M11 2 4 Voice messages Similarly to the above choose between the events with the help of the up and down buttons Give the number of the voice message 01 12 the module should play in case of this event occurs One voice message can be assigned to more events 20 If the voice message number is 0 the module will send only a beep instead of a voice message at calling M11 3 Pho
34. see it you should release the button within 4 seconds e The module has returned to zero settings and the installer code has changed to 1111 again 7 Recording voice messages The GSM Ultimate module is capable to record 12 pieces of 5 second voice messages These messages can be assigned to any of the alarm events or system events see 11 2 4 Thus on alarm call the appropriate voice message will be played according to the event type The next chapter will describe how to record and play voice messages 8 The use of radio devices GSM Ultimate with supplementary radio module is able to accept the signals of radio devices produced by ELMES Ltd These devices are radio infra sensors magnet open close detector window glass break detector key ring remote control with 2 or 4 buttons repeater signal repeater to span distances The devices to be used first have to be assigned to GSM Ultimate module as described in section M11 16 Radio devices Maximum 2 radio sensors can be assigned to each zone in this way 24 sensors can be joined to one GSM Ultimate module In addition a 2 or 4 buttoned key ring remote control can be assigned to each device The functions of the remote control push buttons must be set as it is described in section 11 16 3 RF key assign After the devices have been assigned the zone installation method also has to be set to Radio zone in the zones where radio devices have been assigned section 11 1 2 Zone ins
35. ser Is it armed 2 6 beeps armed 3 beeps disarmed It refers to the partition s that the user has authority to arm through the phone Relay OFF 310 3 beeps ok buzzing not authorised user ON 311 3 beeps ok buzzing not authorised user Enquiry on relay 319 6 beeps relay is ON 3 beeps relay is OFF Relay2 OFF 320 3 beeps ok buzzing not authorised user Relay2 ON 321 3 beeps ok buzzing not authorised user Enquiry on relay2 329 6 beeps relay is ON 3 beeps relay is OFF Relay3 OFF 330 3 beeps ok buzzing not authorised user Relay3 ON 331 3 beeps ok buzzing not authorised user Enquiry on relay3 339 6 beeps relay is ON 3 beeps relay is OFF Voice recording to the 1 memory 8901 The module records 5 seconds after location the beep Voice recording to the 2 memory 8902 The module records 5 seconds after location the beep The module records 5 seconds after the beep Voice recording to the 12 memory The module records 5 seconds after location the beep Listening to recorded voice message 8001 message 1 The module plays back the voice 8002 message from the given memory location 8012 12 If a command is wrong the module signals it with 1 deep beep 11 10 The menu structure of the LCD keypad gt ARMING gt FULL ARM gt ARM PARTITION 1 gt ARM PARTITION 2 gt NIGHT ARM gt DISARMING gt CHANGE USERCODE gt US
36. set how long the module should wait after the occurrence of an activating event before turning on the relay This interval can be set between 0 255 seconds The delay specified here does not refer to telephone remote control When activation is done through the telephone the relay turns on immediately M11 6 3 4 RELE1 time max The maximum time interval for the relay can be set to be in activated state After this time has expired the relay shall turn off even if no deactivating event has occurred This interval can be set between 0 254 seconds Value 255 means that no maximum time has been set for the relay That is the relay gets deactivated only as a result of a deactivating event or remote deactivation through the telephone The parameters of RELE2 and RELE3 can be set the same way M11 7 Alarm time max It can be set between 5 and 25 minutes in minutes how long an event should be valid after its occurrence When this time has expired and some of the telephone calls and SMS message sending fail the module stops the alarm process and does not start any further notification to signal this event This only refers to that special event the telephone calls and SMS messages caused by newer events go on being directed and sent to 23 11 8 Zone alarm max It can be set between 1 and 25 how many signals a zone can send This way we can avoid that a faulty detector shall cause alarm processes permanently The device being
37. sh button is turned off in inactive mode By pressing any button button lighting gets turned on After one minute it restores e LCD On But On Both LCD and push buttons light continuously LCD Off But On Neither LCD nor push buttons lit not even by pressing any button M11 13 2 Doorbell Each zone can be set in a way that the keypad gives out a beep at the sensor s signal For example to signal in case of opening door To set this function you can move the cursor between the zones with the right and left buttons and with the help of any number push button the chosen zones state can be changed back and forth to or signals 24 11 13 3 Settings Other useful functions be set on the keypad M11 13 3 1 Night mute If this function is enabled at night arming and after disarming from night armed state all keypad sound signals turn off except for the short sound signals following pushing any buttons M11 13 2 Signal at alarm If this option is enabled in case of an alarm the keypad goes on hooting for 20 seconds This can be stopped immediately by disarming or by the Stop sounder menu item M11 13 3 3 Quickarm By enabling this function the following functions can be used on the keypad e By pressing push button 1 continuously for 5 6 seconds partition 1 can be armed e By pressing push button 2 continuously for 5 6 seconds partition 2 can be armed e By pressing push butt
38. t only assign the device but you shall set the zone to operate as radio zone as described in section M 1 1 2 Zone type M11 16 2 RF sensor programming B The second secondary radio sensors can be assigned here the same way as described in the previous section 27 M11 16 3 remote key programming A key ring radio remote control with 2 or 4 buttons can be assigned to each user the same way as it was described about the assignment of radio sensors 11 16 4 RF key assign To the buttons of key ring radio remote controls you shall set what functions they should initiate You shall assign to each buttons of the remote control any of the functions described below Arm Part amp Part2 Arm Partl Arm Part2 Night Arm Disarm Relayl Relay2 Relay3 In the last three cases it starts the relay with the delay and timing that was chosen at the relay s setting M11 17 Clear all alarm The installer has the possibility to delete all alarms in process He can do so by choosing this menu 28 GSM aerial COM NO1 NC2 COM2 NO2 NC3 COM3 NO3 a ee Power OW oY OY OW OW OY DY ON GSM 444466666 GPRS card GSM module a error RELAY1 RELAY RELAY3 RS232 connection to PC 22 7 0 927272 AC 16 18V ACCUMULATOR COM NC NO NC LCD KEYPAD TAMPER ALARM
39. tallation method You can perform these settings including the assignment of the devices easier with the attached Ultimate Remoter program v1 22 or newer versions The radio devices signal if their power decreases under 7V The module treats this signal as an event that can be forwarded to the monitoring station or an alerting SMS can be sent to the user There is also the relating noise among the events that informs the monitoring station or the user about a possible radio sabotage attempt while detecting strong disturbing radio signals 10 9 Functions that can reached through a telephone To reach the device through a telephone you have to do the steps as follows e Call the phone number of Ultimate module e The module accepts the phone call and with a beep it signals to be ready to accept commands e Enter user identification in the form of 9password e g in the case of identification 1234 you should enter 91234 e The module signals with three beeps if the password is correct and with a deep beep if it is not e Now you can set the requested commands which you have authority to use according to the table below see M4 3 e At last disconnect the call COMMAND CODE REPLY Entering password Opassword 3 beeps ok 1 deep beep invalid password Arm l 6 beeps ok buzzing not authorised user Disarm 0 3 beeps ok buzzing not authorised u
40. ting data calls therefore it is not possible to get connected to the module through the phone In this case ask the service provider for further assistance In case of GSM Ultimate with radio receiving module make sure to place the radio antenna right Do not place the radio antenna too close to the GSM antenna because at the start of GSM call the strong radiance may disturb and weaken the reception of radio devices s signals GSM and radio antenna should not be mounted on the same side of the metal box e At fixing the device in its place check the strength of further radio devices signals see section 11 16 2 RF sensor programming A Assemble the antennas in a way that their base should metalically touch the metal box 3 7 Installation of power supply Primary power supply 16 18V 40VA transformer Make sure to arm the device only after everything has been installed and there are no hanging cables Ascertain that there are no metallic contacts or litter on the panel and the outputs are not short circuited by anything It is forbidden to assemble any input or output of the alarm system in turned on state Start arming the device by connecting the accumulator first 3 8 Installation of the accumulator The spare power supply of the module is provided by a 12V 7Ah accumulator which assures minimum 72 hour operation in case it is necessary The system cyclically charges and tests the accumulator If the voltage l
41. ws At setting it also has to be taken as DEOL type see M11 1 2 Contact opens on alarm Contact opens on alarm According to the application above the input can have the states as follows 1k Ohm inactive state 2k Ohm alarm 3k Ohm alarm Open sabotage Short sabotage 3 2 Installation of arming disarming circuit You can arm and disarm the module from the keypad from some external unit key switch radio control etc and from a telephone To turn on and off the device from an external unit you can use two inputs input A and B differentiated by partition partition 1 input A partition 2 input The installation of it can be done in three different ways 3 2 1 installation method no 1 controlled by a switch or a rela Activation and deactivation can be done by a switch or a correspondent relay e g by an output of a code switch relay according to the following drawing While setting the device you have to choose wiring mode 1 Switch 1 2 see 11 5 B Sa Ak Closed switch 1k Ohm Arm Open switch 2k Ohm Disarm Short circuit or open Sabotage In the example we have used input B which controls partition 2 3 2 2 installation method no 2 controlled by two kinds of short circuit impulses It might be necessary to have a kind of installation method where arming is done by a short circuit impulse and disarming is done by another s
42. y disassembling the cover of the device E g in case of window breakage sensors this signal can be induced the easiest way by disassembling the cover The module waits half minute for the assignment If there is no signal from the radio device during this time the zone will not be assigned In this case the device assigned to the zone earlier will also be deleted This method can also be used to delete a device assigned by mistake During the time of assignment the module will accept the signals of only those devices that have not been assigned yet So accidental signals from earlier assigned devices will not cause an incorrect assignment After the procedure of assignment you will see a number code in the position of the zone on the bottom line of the keypad that refers to the last signal arriving from the device e g 1 3 sabotage however these carry no importance from the point of view of assignment In case of each signal the keypad will give out a beep and in the position of the zone appears to indicate which zone has signalled A number between 0 and 63 at the end of the bottom line of the keypad indicates the radio field strength of the last received signal At installation find the ideal place of the sensor by paying attention to this so that you can have the best possible reception In case of greater distances or many intermediate walls you shall use radio repeaters For the operation of the radio device you shall no