2. Selection of TOP, External device

image

Contents

1. Vendor Select a model name of the external device which is communicated with TOP Select SIEMENS S7 1200 ETHERNET Check whether the external device you want to use is connectable or not External Device PLC in 1 System configuration XDesignerPlus Communication Manual 3 9 TO CHS HR E RHE Touch Operation Panel 3 Example of system setting Set Communication interface of TOP and external device as below 3 1 Example 1 Set your system as below Set Name TOP S7 1200 Series Note IP Address Note1 Note2 192 168 0 50 192 168 0 51 User Set Subnet Mask 255 255 255 0 255 255 255 0 User Set Protocol TCP TCP User Set Read Port 102 Port 2000 User Set Write Port 102 Notel The first 3 classes of external device s IP and TOP should be same Note2 Do not use the same IP in one network 1 XDesignerPlus Setting Project gt Project property of XDesignerPlus as below and download it to TOP machine kipas m E Project gt Project Property gt Project gt TOP Setting gt PLC Name T E Sopes e EN Set communication interface of SIEMETIC S7 1200 Series Ethernet PLC Setting COM2 0 PLC Comm info COM1 0 Zs z z EJ Ethernet 1 IP Address PLC whe wie PLC1 SIMETIC S7 1200 Read Port 0 65535 102 e S Write Port 0 65535 102 a USB Device 0 CF SD Card Setting IP Address PLC Input appropriate and usable IP address CFISD Card Read Write Port Ch
2. Twisted Pair Cable STP Shield Twisted Pair Cable or UTP Unshield Twisted Pair Cable category 3 4 5 Connection to Herb Trans receiver is available and must use direct cable for this configuration HM Connection configuration TOP number External number e 1 1 TOP 1 unit to External device 1 unit connection XDesignerPlus Communication Manual 2 9 TO HSH CHE RIN Touch Operation Panel 2 Selection of TOP External device Select a external device which is communicated to the TOP HMI PLC Uint XTOP Series Vendor SIEMENS Model XTOP12TS SA SD PLC Model SIMETIC S7 1200 ETHERNET LSIS PROFIBUS SAMSUNG PROFIBUS EX Packet MITSUBISHI 5 S7 300 400 3964R RK512 CP341 OMRON S7 CPU Ethernet Rockwell Allen Bradly 7 200 PPI MODBUS 7 300 400 Ethernet CP343 SIEMENS 7 300 400 MPi Direct GE Fanuc 7 300 400 MPi With PCAdaptor HITACHI SIMETIC S7 1200 ETHERNET _ KDT Systems as KOYO PANASONIC Matsushita Honeywell FATEK YOKOGAWA YASKAWA VIGOR EMOTIONTEK SCHNEIDER DELTA FUJI KEYENCE Setting Items Description Select a TOP series which is communicated with external device Install an OS file v3 1 as diagram below before download a project file you have made Series TOP Series OS Version XTOP HTOP V3 1 Name Select a TOP model which is communicated with external device Select vendor of the external device which is communicated with TOP Select SIEMENS AG
3. SIEMENS AG SIMETIC S7 1200 Series ETHERNET OP Communication Driver Support version OS V3 0 X XDesignerPlus 2 6 34 0 TOP Introduction A Please read this manual carefully to know connection methods and procedures of TOP to External device 1 System configuration Page 2 A section for showing connectable external devices serial signal types connection configurations Refer this section to select the right system configuration 2 Selection of TOP External device Page 3 A section for selecting a Top model and the external device 3 Example of system setting Page 4 A section for explaining examples to connect communications of TOP to External Device Select the correct example in your case according to 1 System configuration 4 Communication setting Page 6 A section for Communication setting The setting should be the same with the external device 5 Usable address Page 8 A section for usable address to communicate with external device XDesignerPlus Communication Manual 1 9 TO HZA E RHE Touch Operation Panel 1 System configuration System configuration of TOP and SIEMENS AG SIEMETIC S7 1200 Ethernet Series Series Link I F Comm type System setting CPU1211C CPU1212C CPU1214C Ethernet TCP SIMATIC S7 1200 PROFINET Interface on CPU 3 1 Setting Example 1 Page 4 Twisted Pair Cable Note1 Notel
4. ces that are usable with TOP is as below There might be difference in the range of device address by type series of CPU module TOP series supports the maximum address range that external device series use Please refer to each CPU module user manual carefully for devices that you desired to use to prevent not getting out of range Input 100000 0 E00000 0 IWw00000 EW00000 Output Q00000 0 A00000 0 QWOO0000 AWO00000 oan K Data Registers DB00001 DBX00000 0 DB00001 DBW00000 aaa ote DB65535 DBX65535 7 DB65535 DBW65534 Note1 Input Device I IW CPU Type can affect to IW0 IW2 writing as CPU is slaved from I O Please refer to PLC manual for more detail Note2 Output Device Q QW QD can write only in Run Mode STOP Mode make output data be reset Note3 32BIT address using check Word swap function Data Size 16bit 32bit Word Swap Note4 When DB settting in TIA Portal SW Symbolic access only must be checked Note5 TWhen setting Data type in DB using TIA Portal SW Bool shape must be 16bit XDesignerPlus Communication Manual 9 9
5. ddress A112 UTETE E eee 1 ISIH Sii Tm it SRT amp Go online Diagnostics General Diagnostics status Standard diagnostics Cycle time hWlerniary Diagnostics butter Functions Set time of day Reset to factory settings g Go offline in if ifs pe L Assign IP address MAC address IP address Subnet screen mask Use router Pronerties Info ul Diaanostics 5 Click Assign IP address after IP setup Note1 This sequence can be changed by device model Refer to PLC manual for more detailed information XDesignerPlus Communication Manual 6 9 Sta ae ERE Touch Operation Panel TO O 4 Communication setting Communication setup can be set on XDesignerPlus or TOP Main Menu The setting should be the same with the external device 1 XDesignerPlus Setup Project l TOP Setting ke XTOP12TS SA SD PLC Setting i COM2 0 COM1 0 J Ethernet 1 ks PLC1 SIMETIC S7 1200 E im Fi uz i USB Device 0 CF SD Card Setting CF SD Card Contents IP Address Read Port Write Port 2 Setting TOP s Main Menu In to the Main Menu While the power of TOP is turned on and the buzzer beeps once Touch the screen s upper part under the TOP logo on the front sheet WE Main Menu gt Comm Setup Communication setup 20 IP Address 192 168 000 050 21 Subnet Mastk 255 255 255 000 22 Gateway 192 168 000 001 23 Port 0 9999 2000 24 Pro
6. munication Diagnosis E TOP Confirming interface setting condition between external devices Move to Menu by clicking the top side of LCD screen as resetting the power of TOP Main Menu gt Communication setting Confirm if detail in number 20 24 is identical to the setup information of H Setup exercise 1 PLC Setup gt Click the button in Communication diagnosis of TOP Ethernet Diagnosis dialog box will pop up on the screen you can judge by following information that is shown on box no 3 section OK The communication status is good Time Out Error The communication status is error Error of the cable or Setting of TOP External device reference communication Diagnosis Sheet E Communication Diagnosis Sheet If you have problems of communication of TOP External device check your system with the sheet below Sd External device IP Address OK NG information o xDesignerPlus Subnet mask Project setting Gateway NG TOP Information Protocol UDP IP TCP IP NG Main Device IP Address OK NG Menu Setting OK Subnet mask Other specified setting info o System System Connection Method configuration 1 1 Name of cable Hub usage Direct Use Hub Cross No Hub NG External Name of CPU OK NG device Name of conmunkatondeice OO y C PSS other specfed semg OOOO NG a a Adaress range conton hero OOOO y XDesignerPlus Communication Manual 8 9 TO HUZA HRH 5 Support Address Devi
7. oose the port No that will be used in 2 2 Set TOP Main Menu In to the Main Menu While the power of TOP is turned on and the buzzer beeps once Touch the screen s upper part under the TOP logo on the front sheet E Main Menu gt Comm Setup Comm Setup 26 Ethernet Timeout 10 100 mSec 27 Ethernet Send Wait 00 10 mSec XDesignerPlus Communication Manual 4 9 2 External device setup TO H OR zs Touch Operation Panel Please set using SIEMENS SW Totally Intergrated Automation Portal V10 For further information of settings please refer to your PLC manual A N Do not use same IP address in one network area M Project 1 Create New Project in Totally Intergrated Automation 2 Select Add new device in Project tree Y Ef Save project aw AL FE x F F Project tree Devices Project Add new device my Devices amp Networks T Device configuration Online amp diagnostics b a Program blocks b Technological Objects ia PLE tags b Watch tables a ae m de pict 7 1200 rack Device overview Module 3 Added device in Project tree needed to be set Program blocks Technological Objects Note Check Symbolic access only check when DB Data Block set 4 Run the Compile after sets for error diagnosis 5 After Compile right click on the device name set in sec
8. tion 2 above and select Download to device Aan DEVICES amp Networks an PLC 1 CPU 1214C AGDGRly Memory ily Device configuration Open ai 4 Online amp diagnostics Openin new editor b lao Program blocks W cut Ctrl b Technological Objects E Copy Ctrl C NE j p Lag PLC tags Paste Ctrl ak E Watch tables x Jeler al Fi Rename F2 t D Local modules t Common data Go to device Fe Languages amp Resources ARR Online access ia 7 SIMATIC Card Reader Compile Download to device All Jetails view g Go online aw Go offline bl arna XDesignerPlus Communication Manual 4 Online amp diagnostics Hardware configurati Software Ctrl D Software all blacks 5 9 E IP setting TO HNA E RHE Touch Operation Panel 1 Expand Project tree in Online access and click a connectable path 2 Expand Marvell Yukon 88E8039 PCI E Fast Ethernet Controller LAN Port H W Note1 You can see current IP address and another tree 3 Expand IP xxx xxx x xxx CPUcommon and select Online amp diagnostics for IP change Devices Y Project i Add new dewice py Devices amp Networks gt P PLC_1 CPU 1214C ACIDC Rly d at Common data 4 d F Languages amp F g Online access 0 Online amp diagnostics P Program blocks t GH Technological Objects E SIMATIC Care Reacler 4 After setup menu popup click Funtions Assign IP address and set IP a
9. tocol TCP 25 Ethernet Station Num In Diag 0 31 00 26 Ethernet Timeout 10 100 mSec 27 Ethernet Send Wait 00 10 mSec oot izi 20 IP Address 21 Subnet Mask 22 Gateway 23 Port 24 Protocol 25 Ethernet Station Num In Diag 0 31 00 26 Ethernet Timeout 10 100 mSec 27 Ethernet Send Wait 00 10 mSec XDesignerPlus Communication Manual WE Setting external device Set communication interface of SIEMETIC S7 1200 Series Ethernet PLC Comm Info o IP Address PLC 192 S 68 Lo 15 Read Port 0 65535 102 ra Write Port 0 65535 102 IP Address PLC IP address for external device Read Wrtie Port Input the port number for input and output Description Input the IP number of external device Select port number of external device for communication Ethernet Port Communication Setup us Setup the IP address that TOP receives in the network Input subnet mask of network Input subnet mask of network Port setup automatically when S7 1200 Series and TOP are connected Choose allowed protocol from S7 1200 Series and set port number 1 N communication choose the station number you set in XDesignerPlus Waiting time for reply from external device 0 99 x 100 mSec Time between receiving device s reply and sending next signal 0 99 x 10 mSec 7 9 TO HSI HR E RHE Touch Operation Panel 3 Com