Home
Model 4201 RPM Programmer User`s Manual
Contents
1. FAST SLOW response ERROR MESSAGES The following error messages may be displayed CPEn The No 4201 is not connected to the RPM possibly indicative of a broken cable SHOr The two alligator clips are shorted together or their polarity is reversed The No 4201 will automatically shut off after flashing this message 5 times Erri The RPM being programmed has a DIP switch can t be programmed with the No 4201 Err2 The address entered is O or greater than 255 FAIL Programming was unsuccessful indicating a possibly faulty RPM which should be repaired or replaced 5 BATTERY REPLACEMENT Replace the batteries when LOW BATTERY message is displayed 1 Remove the 2 battery compartment cover screws and remove cover 2 Unplug the old batteries from the battery clips and replace with fresh 9 volt alkaline type batteries Place batteries in the compartment keeping the terminal clips to the left side of the compartment 3 Replace the battery compartment cover securing it with the 2 screws SPECIFICATIONS Dimensions 7 5 8 x 4 x 2 1 4 Power Three 9 volt alkaline type batteries Operating Temperature 32 F to 120 F 0 C to 50 C Storage Temperatura 4 F to 140 F 20 C to 60 C ADEMCO UMITED WARRANTY Alarm Device Manufacturing Company a Division of Pittway Corporation Seller 165 Eileen Way Syosset New York 11791 warrants its security equipment the procuct to be free rom defects in m
2. authorized A DEMCO ALARM DEVICE MANUFACTURING CO i A DIVISION OF PITTWAY CORPORATION 165 Eileen Way Syosset New York 11791 N3300V1 7 88 Copyright 1987 PITTWAY CORPORATION
3. ADEMCO _USER S MANUAL INTRODUCTION i The Ademco No 4201 RPM Programmer is a handheld device used to program addresses and response modes fast slow for Remote Point Modules RPMs that do not utilize a DIP switch Programming is accomplished by keypad entries which are displayed on an LCD display window The No 4201 can also be used to troubleshoot faulty RPMs even those with a DIP switch by displaying the RPM s unique address Multiple addresses indicates a fault The No 4201 is powered by three 9VDC alkaline type batteries located in the battery compartment below the keypad The No 4201 indicates low battery voltage by displaying the message LOW BATTERY on the display window Batteries should be replaced at that time Note Not all RPMs have this option Refer to the RPM Installation Instructions for details OPERATION The No 4201 is connected to the polling loop terminals of the RPM to be programmed by a supplied interface cable which has a phono plug and two alligator clips NOTE The RPM must be disconnected from its polling loop and only one RPM can be programmed or verified at a time with the No 4201 The No 4201 is activated by pressing the POWER key and will automatically shut off 60 seconds after the last time a key is pressed The software version number will be displayed for 1 second upon power up after which the word On will be displayed Keypad entries are accemplished by momentarily depressin
4. EN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Seller does not represent that the product may not be compromised or circumvented that the product will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Buyer understands that a properly installed and maintained alarm may only reduce the risk of a burglary robbery or tire without warning but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING However if Seller is held liable whether directly or indirectly for any loss or damage arising under this Limited Warranty or otherwise regardless of cause or origin Seller s maximum liability shal not in any case exceed the purchase price of the product which shall be the complete and exclusive remedy against Seiler This warranty gives you specific legal rights and you may also have other rights which vary from state to state No increase or alteration written or verbal to this warranty is
5. aterials and workmanship for one year from date of original purchase under normal use and service Seller s obligation is limited to repairing or replacing at its option ree of charge for parts labor or transportation any part proven to be detective in materials or workmanship under normal use and service Seller shall have no obligation under this warranty or otherwise if the productis altered or improperly repaired or serviced by anyone other than the Seller In case of defect contact the security professional who installed and maintains your security system or the Seiler for product repair This one year limited Warranty is in lieu of all other express warranties obligations or liabilities THERE ARE NO EXPRESS WARRANTIES WHICH EXTEND BEYOND THE FACE HEREOF ALL IMPLIED WARRANTIES OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECTION WITH THIS PRODUCT INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE ANY ACTION FOR BREACH OF ANY WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY MUST BE BROUGHT WITHIN 18 MONTHS FROM DATE OF ORIGINAL PURCHASE IN NO CASE SPALL SELLER BE L ABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY continued on next page 7 OTHER BASIS OF LIABILITY WHATSOEVER EV
6. g the appropriate key s Each key must be completely released befcre the next key is pressed Note that the No 4201 s LCD display operates best at room temperature If the unit has been exposed to cold temperatures ex stored in trunk of car allow it to warm up for 15 minutes at reom temperature before operating KEYPAD FUNCTIONS RPM addresses are programmed by first entering a number from 1 255 leading zeroes not required then pressing FUNC PROG 3 Additional keypad functions are activated by first pressing the FUNC key followed by pressing the appropriate labeled key for the desired function The No 4201 keypad functions are FUNC DISP 1 This function displays the current address of an RPM and is used to identify unknown RPM addresses or to verify address programming FUNC PROG 3 This function transfers the previously entered address and response mode data to the RPM Refer to the PROGRAMMING AN RPM section for specific programming details FUNC FAST 4 This function sets the fast response time for the RPM FUNC SLOW 6 This function sets the slow response time for the RPM FUNC CLEAR 7 This function clears the display window for key entry changes and resets the No 4201 for programming the next RPM Displays On FUNC TEST Q This function activates the test function currently inactive 1 3 PROGRAMMING AN RPM T 2 3 Connect the interface cable by p
7. lugging the phono plug into the faceplate jack and connect the alligator clips to the RPM polling loop terminals Red to Black to Activate the No 4201 by pressing the POWER key Automatically shuts off Programming k y entry format is as follows ADDRESS FAST 4 or SLOW 6 if available PROG 3 Where ADDRESS numerical keys corresponding to RPM s address 1 255 Omit the FAST SLOW entry if not available for RPM it is ignored if programmed When entry is completed the word PASS and the entered address will alternately flash 4 times indicating successful programming If the word FAIL appears it indicates a possibly faulty RPM Repeat the programming procedure If FAIL still appears the RPM must be repaired or replaced To change an entry press FUNC CLEAR 7 Disconnect the cable clips from the RPM and repeat procedure for each RPM to be programmed VERIFYING AN RPM S ADDRESS To verify the address of an RPM or display an RPM s unknown address connect the cable as described in step 1 above then press FUNC DISP 1 The flashing symbol _ indicates an address search is in progress The current address of the RPM will then flash 4 times If more than one address flashes it indicates that the RPM is defective and must be repaired or replaced Note that the verification feature can be used on any type of RPM including those with DIP switches and verifies addresses only not
Download Pdf Manuals
Related Search
Related Contents
Kicker 50 Si User's Manual WUH4A PTN 4K HDMI Switcher 4x1 - PTN E SERIES MK2 User Manual - produktinfo.conrad.com つなぎかたガイド - 121ware.com Bedienungsanleitung Nextbase Media 22 - next 0450000500-1437 Installationsanleitung heatapp! System USER'S MANUAL the User Manual Villard Bonnot, le « Copyright © All rights reserved.