Home

Model No. SR6-SONY

image

Contents

1. further away from 5 volts the faster the shuttle speed The closer to 5 volts the slower the shuttle speed AMPEX VPR 2 Interface Connector 15 Pin D type female Pin 1 Not Used 2 Not Used 3 Record Command Active Low Open Collector Output 4 Play Command Active Low Open Collector Output 5 Stop Command Active Low Open Collector Output 6 Shuttle Voltage Active Low Open Collector Output 7 Not Used 8 Shuttle Command Active Low Open Collector Output 9 Command amp Status Common 10 Local Status Input Active Low Input Internal pullup to 5 VDC 11 Play Status Input Active Low Input Internal pullup to 5VDC 12 Record Status Input Active Low Input Internal pullup to 5 VDC 13 Fast Forward Status Input Active Low Input Internal pullup to 5 VDC 14 Rewind Status Input Active Low Input Internal pullup to 5 VDC 15 Stop Status Input Active Low Input Internal pullup to 5 VDC Installation is complete 3 SR6 SONY Serial to Parallel Converter 4 OPERATION Upon receipt of the RECORD PLAY or STOP command the SR6 outputs a momentary GPI LOW 250 milliseconds in duration on the appropriate output The RECORD command pulses both the RECORD PLAY GPIs Receipt of the REWIND or FFWD command causes the SR6 to output a latched GPI LOW on the REWIND FFWD output and a pulsed output on the Shuttle Command output VPR 2 mode OR output a momentary GPI LOW 250 milliseconds in duration on the REWIND FFWD output This is user configured using
2. the Rear Panel DIP Switches For latched operation the next received command clears all previously latched outputs 5 FUNCTIONS GPI OUTPUTS FUNCTION RECORD PLAY STOP REWIND FFWD Shuttle Command Ampex VPR2 Mode only G Lh E LALA a The front panel LEDs turn on to indicate GPI ACTIVATION Status Tally Inputs The SR6 STATUS INPUTs require an active low pull to Status Common on the desired input for proper status detection The active low can be provided by an open collector output switch closure relay contact closure or TTL signal Each STATUS INPUT has an internal pullup to 5 VDC It is recommended that an opto isolator be used with each Status line from the VPR 2 The emitter of the output transistor on the opto isolator output should be tied to Status Common The collector of the output transistor should be tied to the desired STATUS INPUT Set Rear Panel DIP Switch 5 to ON 4 SR6 SONY Serial to Parallel Converter Rear Panel DIP Switches NOTE Switches are read Only on power up After making changes to the switches turn the unit off then on for changes to take effect Switch Function 1 4 Not Used 5 Source of Status Tallies ON Use Controlled Device Status Tallies OFF SR6 generates Status Tallies from received commands 6 GPI Output ON AMPEX VPR 2 mode OFF All GPI outputs are pulsed low 250 milliseconds 5 SR6 SONY Serial to Parallel Converter 6 SPECIFICATIONS Front Panel
3. types of damage resulting from the use of the product HHH 9 SR6 SONY Serial to Parallel Converter
4. 12843 Foothill Bivd Suite D Sylmar CA 91342 818 898 3380 voice hl EE EEE OO JD JD J JE ay AEE ee eee z EE EE EE 1 H 7 EEE GEE OO D EOE 29 EEE EEO EE 818 898 3360 fax CONTROLS www dnfcontrols com Model No SR6 SONY Serial to Parallel Converter USER MANUAL Manual VerSion 0eeceeeeeeeeeeeeeeeeeeeeees 2 1 120403 a ar anne eo aes SR6 SONY User Manual doc SR6 SONY Serial to Parallel Converter 1 REVISION HISTORY 120403 Rev 2 1 Company header information revised Added DNF Controls Limited Warranty DESCRIPTION The SR6 SONY Serial In to Parallel Out Converter provides simple emulation of the SONY BVU 800 The SR6 converts the following SONY serial commands into six open collector GPIs RECORD PLAY STOP REWIND and FAST FORWARD Additionally the SR6 SONY accepts the following 6 tallies from the controlled device to provide real time status to the control point LOCAL RECORD PLAY STOP REWIND and FAST FORWARD NOTE It is recommended that an opto isolator be used on each tally line from the Controlled Device to the SR6 SONY The SR6 SONY can be configured to control an AMPEX VPR 2 or provide a standard 250 millisecond pulsed GPI output using the Rear Panel DIP switches INSTALLATION Plug one end of a 9 conductor RS422 serial cable into the 9 pin connector on the rear of the SR6 SONY Plug the other end of the cable into the 9 pin connector on the controller Plug the 9 pin D t
5. 6 Status LEDs Record Play Stop Rewind FFWD Jog 1 Power LED Size 1 RU 9 Lx 1 75 Hx 4 5 D Weight 5lbs Rear Panel Connectors RS422 Serial In 9 Pin D type connector female DB9 F Power 5 volt D C 500 ma 90 265 VAC 50 60 Hz converter Supplied DB9M VTR Interface 15 pin D type connector female DB15F Switch Output Open collector sink 50mA Status Input SPST contact closure momentary POWER CONNECTOR 9 Pin D type male DB9M Pin 1 5v DC 6 5 VDC 2 5v DC 7 Ground 3 Ground 8 Ground 4 Not Used 9 Ground 5 Not Used RS422 SERIAL CONNECTOR 9 Pin D type female DB9F Pin 1 Frame Ground Transmit A gt Receive B Transmit Common Spare Receive Common Transmit B gt Receive A Frame Ground D 9 4 G Lh E LA LA D SR6 SONY Serial to Parallel Converter STANDARD VTR INTERFACE CONNECTOR 15 Pin D type female DB15F Pin 7 1 Not Used 2 Not Used 3 Record Command Active Low Open Collector Output 4 Play Command Active Low Open Collector Output 5 Stop Command Active Low Open Collector Output 6 Rewind Command Active Low Open Collector Output 7 Fast Forward Command Active Low Open Collector Output 8 Not Used 9 Command amp Status Common 10 Local Status Input Active Low Input Internal pullup to 5 VDC 11 Play Status Input Active Low Input Internal pullup to 5VDC 12 Record Status Input Active Low Input Internal pullup to 5 VDC 13 Fast Forward Status Input Active L
6. ow Input Internal pullup to 5 VDC 14 Rewind Status Input Active Low Input Internal pullup to 5 VDC 15 Stop Status Input Active Low Input Internal pullup to 5 VDC SR6 SONY Serial to Parallel Converter Typical Connection Diagram RP uzmi DBI5F Adapter included NOT USED POWER SRE SONY SUPPLY NOT USED 7100 s em TYPICA I H Loop THAU via E 7 L VTR DDR o a U PARALLEL CONTROL 9 Pn na ASAD i oe sts MULTI PIN CONNECTOR RECORD STATUS FFWD STATUS REW STATUS STOP STATUS SR6 SONY TO SONY 33 PIN PARALLEL CONTROL SONY 33 PIN PARALLEL CONTROL DB15 FEMALE 33 PIN FEMALE PIN SRE SONY STOP FFWD REWIND PLAY RECORD COMMON 8 SR6 SONY Serial to Parallel Converter 7 DNF CONTROLS LIMITED WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one 1 year from the date of sale to the original purchaser from DNF Controls In order to enforce the rights under this warranty the customer must first contact DNF s Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair If DNF s Customer Support Department cannot fix the problem the customer will be issued a Returned Merchandise Authorization number RMA The customer will then ship the defective product prepaid to DNF Controls with the RMA number clearly indicated on the customer
7. s shipping document The merchandise is to be shipped to DNF Controls 12843 Foothill Blvd Suite D Sylmar CA 91342 USA Failure to obtain a proper RMA number prior to returning the product may result in the return not being accepted or in a charge for the required repair DNF Controls at its option will repair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principally UPS Ground for shipments within the United States of America Shipments to international customers will be sent via air Should a customer require the product to be returned in a more expeditious manner the return shipment will be billed to their freight account This warranty will be considered null and void if accident misuse abuse improper line voltage fire water lightning or other acts of God damaged the product All repair parts are to be supplied by DNF Controls either directly or through its authorized dealer network Similarly any repair work not performed by either DNF Controls or its authorized dealer may void the warranty After the warranty period has expired DNF Controls offers repair services at prices listed in the DNF Controls Price List DNF Controls reserves the right to refuse repair of any unit outside the warranty period that is deemed non repairable DNF Controls shall not be liable for direct indirect incidental consequential or other
8. ype female connector on the POWER SUPPLY into the male 9 pin connector on the rear of the ST100 Plug the AC connector into a wall outlet 90 VAC 265 VAC 50 60 Hz Select REMOTE operation on the VTR s front panel INSTALLATION for Standard VTR Set Rear Panel DIP Switch 6 to OFF Wire the desired command lines to the controlled VTR per the Standard VTR Interface Connector chart Wire the Command Common to the VTR Command Input Common If Controlled Device Status Tallies are to be returned to the controlling point ALL tallies must be connected Local Play Record FFWD Rewind and Stop It is recommended that an opto isolator be used on each tally line from the Controlled Device to the SR6 SONY Set Rear Panel DIP Switch 5 to ON Installation is complete 2 SR6 SONY Serial to Parallel Converter INSTALLATION for AMPEX VPR 2 Wire SR6 pin 9 to AMPEX pin 31 Ground Wire SR6 pin 3 to AMPEX pin 5 Record Wire SR6 pin 4 to AMPEX pin 1 Play Wire SR6 pin 5 to AMPEX pin 15 Stop Wire SR6 pin 8 to AMPEX pin 20 Shuttle Command Wire SR6 pin 6 to AMPEX pin 16 through 27K ohm 1 4 Watt series resistor Wire AMPEX pin 4 12 Vdc to AMPEX pin 16 through 100K ohm 1 4 Watt series resistor The value of the 27K and 100K resistors can be adjusted for a desired shuttle speed per the following When pin 16 voltage is gt 5 volts the tape shuttles forward 5 volts the tape shuttles reverse The