Home

Model HPC400

image

Contents

1. JOFRA Marine Instruments A complete range of calibration equipment for temperature pressure and signal approved for marine use FP Temperature Sensors A complete range of temperature sensors for industrial and marine use M amp G Pressure Testers Pneumatic floating ball or hydraulic piston dead weight testers with accuracies to 0 015 of reading M amp G Pumps Pressure generators from small pneumatic bicycle style pumps to hydraulic pumps generating up to 1 000 bar 15 000 psi because calibration Is a matter of confidence www jofra com Sales amp Service Offices AMETEK Mansfield amp Green North America Tel 1 800 527 9999 e cal info ametek com AMETEK Singapore Pte Ltd Singapore Tel 65 6 484 2388 aspl ametek com sg AMETEK Inc Beijing Rep Office China Tel 86 10 8526 2111 jofra ametek com cn AMETEK GmbH Germany Tel 49 2159 9136 510 e info mct de ametek de AMETEK Calibration Instruments UK Tel 44 0 1243 833 302 jofra ametek co uk 8 www jofra com
2. csccsseeeseeeees 0 to 2 bar 30 psi Pressure range T 970 cccceccseeeeeees O to 20 bar 800 psi AND E E E T EEE E E E enc Pneumatic Test MOCIUM cccceccceseeceececeeeceeeesaeeesaeeeeaeseeseeseeeesseesees Air e121 113 Renn te ee eee ee AAAA Scissor SMM S teeth ENT E EE Buna N Wetted parts Aluminum brass stainless steel nylon Nylatron GS Connection to test object Hose 0 6 m 24 in with 1 4 BSP and NPT female terminations IZ OC TEEN 21 6x12 1x6 2 cm 8 5x4 8x2 4 in WY CIM TE TAE A E 1 4 kg 3 0 Ib Included with System A delivery e HPC standard delivery see page 5 e Hand pump T 960 or T 970 with a 0 6 m 24 in hose with 1 4 BSP and NPT female terminations e 3 8 BSP female adapter with 1 4 BSP and NPT female terminations e Quick connector between pump and HPC calibrator e 1 roll of Teflon tape e Protective carrying case Accessories e Pressure hose for T 960 970 0 5 meter e Pressure hose for T 960 970 1 0 meter e Pressure hose for T 960 970 2 0 meter e Pressure hose for T 960 970 5 0 meter e Set of BSP female fittings Teflon tape packings Fitting size 1x1 8 1x3 8 1x1 2 e Set of NPT female fittings Teflon tape packings Fitting size 1x1 8 1x1 4 1x3 8 1x1 2 e Connections for APM H S pressure modules e Fitting 1 8 NPT male to 1 4 NPT male for APM H pressure module e Fitting 1 4 NPT male to 1 4 NPT male
3. 1 4 NPT male from 1 8 BSP male Adapter to 1 4 BSP female from 1 8 BSP male 1 8 sealed gasket washer type Test leads red and black Hand strap with clip User manual Model HPC400 Handheld Pressure Calibrator www jofra com JOF RA HPC400 System A e AXX 0 to 2 bar 0 to 30 psi e AHX 0 to 20 bar 0 to 300 psi This system includes the HPC calibra tor together with one pneumatic hand pump T 960 and T 970 depending on the chosen pressure range System A is an easy to use single hand operated calibration system No need for a flat surface to operate the system just hold it in your hand The system comes in a carrying case with cut outs for fit tings hose and the complete assembled calibration unit no time is required to assemble the unit The calibrator can at any time be used separately for other pressure test jobs A special quick connector between the pump and the calibrator makes it possible to separate the system in sec onds and swivel the calibrator for easy viewing The HPC calibrators used in System A are delivered cali brated in both pressure and vacuum T 960 and T 970 pumps for system A Model T 960 pneumatic pressure pump features an extended range volume adjuster for precise control of the pump pressure and a comfortable pistol grip handle Model T 970 pneumatic pressure pump is similar to the T 960 but generates pressures up to 20 bar 290 psi Pressure range T 960
4. for APM S pressure module HPC400 System B e BXX Vacuum to 2 bar 30 psi e BHX Vacuum to 20 bar 300 psi This system includes the dual func tion pneumatic hand pump With this pump you can calibrate both vacuum and pressure applications It takes just a few seconds to switch between vacuum and pressure just push one but ton valve on the hand pump The System B comes in a carrying case with cut outs for fittings hose and the complete assembled calibration unit no time required to assemble the unit before use The calibrator and the pump are fitted with a special quick connector that makes it possible to separate the system in seconds without any tool This quick connector also makes it possible to use the assembled system with the calibrator twisted to any angle T 965 and T 975 hand pumps for system B Model T 965 and T 975 pneumatic pressure pumps fea ture both vacuum and pressure generation Quick switch valve makes it easy to switch from vacuum to pressure measurement A built in release valve a volume adjuster for fine adjustment and a dual pressure output enable a safe and simple operation The unit offers both metric and imperial threads on the reference connection and the hose Pressure range T 965 008 vacuum to 2 bar 30 psi Pressure range T 975 vacuum to 20 bar 300 psi TYD eee eee ee eee eee ae ee Pneumatic Test medii seess Air OperatOM ssiiissaninda ansen annA EEREN R
5. switch tests switch in HART resistor or other calibration tasks assisted by the outstanding functions and features of the HPC400 Electrical connections HPC calibrators are well equipped and include inputs for mA voltage switches and temperature measurements including 24 VDC supply for mA transmitters Units 15 different pressure engineering units Pressure connections 1 8 BSP female 300 series stainless steel 1 4 NPT male and 1 4 BSP female adapters are supplied as standard FUNCTIONAL SPECIFICATIONS Pressure gauge compound ranges Dl A E E EAEE N A A I NT 0 96 to 2 7 amp 20 IS EEE E E A T EE A 14 to 15 100 amp 300 Engineering units built in User Selectable cccccccsecccseccesseeeeeeeeeeesseeeeseeenaes 15 units bar mbar MPa kPa inHg 0 C mmHg 0 C kg cm mmH 0 4 C mmH O0 20 C psi inH O 4 C inH O 20 C inH O 60 F cmH 0 4 C cmH O0 20 C Pressure accuracy ambient temp 18 to 28 C 65 to 82 F All pressure ranges cccsececeeeeeseeeeeeeeeeeeseeees 0 05 F S Le E KAUN a EETA E A EE AE IAEE EEN 0 10 F S F S full scale is the numerical value of the positive pressure range Temperature effect outside 18 to 28 C 65 to 82 F 0 005 F S C Accuracy includes hysteresis nonlinearity repeatability and reference standard uncertainty 1 Year typical long term stability operated inside the rated temperature span and pressure range Requiring frequentl
6. EARNAN EAERI Scissor O A eea E S Buna N Wetted parts Aluminum brass stainless steel nylon Nylatron GS Connection to test object Hose 0 6 m 24 in with 1 4 BSP and NPT female terminations SIZ E E 21 6x12 1x6 2 cm 8 5x4 8x2 4 in TE OMG E E AEA AE NTT 1 4 kg 3 0 Ib Included with System B delivery e HPC standard delivery See page 5 e Hand pump T 965 or T 975 with a 0 6 m 24 in hose with 1 4 BSP and NPT female terminations e 3 8 BSP female adapter with 1 4 BSP and NPT female terminations e Quick connector between pump and HPC calibrator e 1 roll of Teflon tape e Protective carrying case Accessories e Pressure hose for T 975 0 5 meter e Pressure hose for T 975 1 0 meter e Pressure hose for T 975 2 0 meter e Pressure hose for T 975 5 0 meter e Set of BSP female fittings Teflon tape packings Fitting size 1x1 8 1x3 8 1x1 2 e Set of NPT female fittings Teflon tape packings Fitting size 1x1 8 1x1 4 1x3 8 1x1 2 e Connections for APM H S pressure modules e Fitting 1 8 NPT male to 1 4 NPT male for APM H pressure module e Fitting 1 4 NPT male to 1 4 NPT male for APM S pressure module ORDERING INFORMATION Order number HPC 400 NONE 002C 007C 020C G IND AXX AHX BXX BHX HPC 400 020C G BC BHX Model HPC400 Handheld Pressure Calibrator JOF RA Description Type Model No calibrator pressure system on
7. ly Pressure range Vacuum to 2 bar 30 psi gauge compound Vacuum to 7 bar 100 psi gauge compound Vacuum to 20 bar 300 psi gauge compound Calibration certificate NIST traceable calibration certificate Accessories Optional Rechargeable battery pack Soft case Pressure system Calibrator only Syst A T 960 pump ranges up to 2 bar 30 psi Syst A T 970 pump ranges up to 20 bar 300 psi Syst B T 965 pump ranges up to 2 bar 30 psi Syst B T 975 pump ranges up to 20 bar 300 psi Sample order number HPC400 vacuum to 20 bar NIST traceable certificate rechargeable battery package soft case system B T 975 pump AWAY Oligemerelan ACCESSORIES Rechargable battery kit Option B The HPC400 is available with a set of 4 rechargeable AA batteries and a charger Useful soft case Option C The HPC400 can be delivered with a soft case as an option The handy soft case is designed for protection during transport The soft case has separate compartments for HPC400 w Velcro strap test leads test hoses and temperature probe A shoulder strap ensures convenient transportation when climbing ladders etc and the handy strap makes it possible to hang the instrument on a valve ladder etc The manual and calibration documents fit into a pocket on the front of the soft case Complete calibration systems The HPC400 is available as a calibrator only or one of 6 ready for test systems that are complete and equipped to meet your press
8. pressure SOF RA Handheld Pressure Calibrator Model HPC400 Pressure ranges HPC400 2C Vacuum to 2 bar 30 psi HPC400 7C Vacuum to 7 bar 100 psi HPC400 20C Vacuum to 20 bar 300 psi Transmitter loop features Transmitter loop measurement 24 volt DC loop supply and HART resistor Easy pressure switch test Opening and closing pressures are automati cally recorded and deadband is calculated All is presented in a large graphical display Useful set of features The HPC400 offers a selection of useful features voltage measurement high speed minimum maximum hold 5 user specified setups high or low resolution and dampened readout for fluctuating pressures The HPC400 series is a true calibrator a field instrument designed for Ready to use systems easy and reliable check and calibration of pressure Use the HPC400 The HPC400 is available as a complete series in process control applications such as verification or calibration of pressure gauges transducers transmitters pressure switches and safety valves system or as an independent instrument The systems are ready for use complete with calibration pump hose fittings and a convenient hard case to store the complete The HPC400 series is recognized for its high quality and carefully selected time saving features making calibration tasks easy to perform All relevant information is shown in the large multi information display at once such as 15 different pressu
9. re units transmitter mA reading min max recording peak reading and semi automatic pressure switch test recording the closing opening and hysteresis pressure deadband and 5 user specified setups for frequent measurement calibration jobs system Maintenance of the instrument is easy Recalibration of the unit can be performed locally with an accurate pressure reference no need to send the unit back to the manufacturer for recalibration For all systems pump and calibrator are separate so replacement of the pump does not require return of the complete system for repair The HPC can be delivered as an individual calibrator or as a complete calibration system ready for use in a carrying case including pump hose connectors battery test leads user manual and traceable calibra tion certificate AMETEK CALIBRATION INSTRUMENTS ISO 9001 Manufacturer Specification Sheet SS HPC400 JOF RA Clear graphical display Large backlit graphical display shows the pressure Icons show current status and mode 1 2 or 3 measurement windows to suit your applications and demands Intuitive menu system Combination of soft keys and cursor keypad ensures an easy operation Zero To keep high accuracy a dedicated zero button is av il able to provide convenient zero before test ON OFF Auto shut off to expand battery life time user program mable Useful set of features Perform semi automatic pressure
10. ure calibra tion needs Option C AMETEK CALIBRATION INSTRUMENTS Headquarters AMETEK Denmark A S Gydevang 32 34 3450 Aller d Denmark Tel 45 4816 8000 ametek ametek dk Sales amp Service Europe Asia Africa Middle East and South America Oktober 2009 Information in this document is subject to change without notice 2009 by AMETEK Inc www ametek com All rights reserved AMETEK Calibration Instruments is one of the world s leading manufacturers and developers of calibration instruments for temperature pressure and process signals as well as for temperature sensors both from a commercial anda technological point of view JOFRA Temperature Instruments Portable precision thermometers Dry block and liquid bath calibrators 5 series with more than 25 models and temperature ranges from 90 to 1205 C 130 to 2200 F All featuring speed portability accuracy and advanced documenting functions with JOFRACAL calibration software JOFRA Pressure Instruments Convenient electronic systems ranging from 25 mbar to 1000 bar 0 4 to 15 000 psi multiple choices of pressure ranges pumps and accuracies fully temperature compensated for problem free and accurate field use JOFRA Signal Instruments Process signal measurement and simulation for easy control loop calibration and measurement tasks from handheld field instruments to laboratory reference level bench top instruments
11. x 20 F S Power supply BAON ni seuncceesaceenen 4 x 1 5 VDC Alkaline Battery tyPe cccceccsseecseeeeeeeeeeeeeees AA LR6 MN1500 AM3 Battery lifetime cccceeeeeee Typically more than 35 hours Low battery indicator ce ceccseseeeseseteeeetesasetenaeeeenes Yes Instrument dimensions LxWxH Calibrator cccccssceeeeseeees 201x99x50 mm 8 3x3 9x2 0 in HPC400 weight incl battery ceeeee 635 g 22 4 oz Calibrator shipping 243x180x80 mm 9 6x7 1x3 1 in Calibrator weight shipping ccceeeeeeee 1 1 kg 39 5 oz Miscellaneous Compliance EN 61326 2006 amp CISPR 11 Edition 5 0 2009 Class B WANNA Oligcmerelan JOF RA Function Feature HPC400 Single sensor high accuracy pressure calibrator Select display high or low resolution Yes JOF RA HPC400 PRESSURE RANGES This table shows the resolutions that can be obtained by the HPC calibrators throughout all engineering units 20 133 C100 300 2000 n a Static pressure psi 30 000 100 00 300 00 C O Pa n a 3 n a aw Proof pressure maximum allowable pressure without a shift in calibration Burst pressure sensor damaged or destroyed some risk of personal injury STANDARD DELIVERY HPC Calibrator e HPC400 calibrator Traceable calibration certificate NIST with pressure and vacuum performance 4 x 1 5 volt batteries Adapter to
12. y zeroing Display E E E AAAA V A E A Graphical with light Display resolution cccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeneeeeenes 5 digits Display update cccscccceeeeceeeseseeeeees 3 times per second Input output 18 to 28 C 65 to 82 F MA TINGO rannin Oto 24 mA IMA AaCCUFaCY 1 cceeeeceeceeeeeeeeeeeeeeeeeneees 0 015 RDG 2 pA Transmitter SUDDIY ccccccceesseeeeeeeeeseeeeeeees 24 VDC 10 Voltage measurement cccceeeeeeeeeeeeeeeeeneeees 0 to 30 VDC Voltage ACCULACY cceeceeeeeeeeeeeeeeeees 0 015 RDG 2mV HART resistor ccccccccseeeseeececeeeeseeeeeeaeeeseeeeeeseneaaas 250 Q Peak hold Capture cccceceeseeeeeeeeeeeeees 50 milliseconds Switch test INPUT eee eeeeceeeeeeeeaeeeeeeseeeees 5V lt 1mA Temperature effect outside 18 to 28 C 65 to 82 F 0 001 F S C Media compatibility Nickel plated brass and 316 stainless steel Model HPC400 Handheld Pressure Calibrator JOF RA Environmental Operating temperature 10 to 50 C 14 to 122 F Storage temperature 00000 20 to 60 C 4 to 140 F Ingress protection rating cceceeeeee eee eeeeeeeeeeeeeeeeeeeeees IP54 Pressure connection All calibrators wsccccicccucssiuaretindasntbesimoeueubiease 1 8 BSP female Adapters to 1 4 NPT male and 1 4 BSP female are included as standard Pressure overload Overload alarm OL in display at appro