Conext™ SW Inverter Charger
Contents
1. 0 9 m cable 7 6 m cable 22 9 m cable Product Accessory Shown above Product Number s 1 Conext SW DC Switchgear 865 1016 2 Conext SW AC Switchgear 865 1017 61 3 Stacking Kit not shown 865 1019 61 4 MPPT 60 150 Solar Charge Controller 865 1030 1 MPPT 80 600 Solar Charge Controller not shown 865 1032 5 Conext SW On Off Remote Switch not shown 865 1052 6 System Control Panel SCP 865 1050 7 Conext ComBox 865 1058 8 Automatic Generator Start AGS 865 1060 9 Battery Temperature Sensor BTS 808 0232 02 10 3 ft network cable 0 9 m 809 0935 25 ft network cable 7 6 m 809 0940 75 ft network cable 22 9 m 809 0942 975 0636 01 01 Rev B 2 3 Components and Mechanical Features Conext SW Inverter Charger Mechanical Features Figure 2 2 Conext SW Front and Side Panels Conext SW Front and Side Panels Before you begin to operate the Conext SW review the front panel features shown in Figure 2 3 and described in the next table A detailed view of the lights and buttons on the front panel is also shown Item Description 1 Front Panel contains the Inv Enable and Clear Fault Reset buttons as well as various LEDs status indicator lights See Front Panel Buttons and Status LEDs on page 2 5 Network and communications ports See AC and
2. 3 15 Navigate To Conext SW Setup Menu 3 16 Conext SW Setup Menu Operational Settings 3 18 Selecting Basic Settings 4 4 Selecting Advanced Settings 4 6 Menu Map of the Conext SW Basic Settings 4 7 Inverter Settings Menu Screen 4 9 Charger Settings Menu Screen 4 13 Custom Settings Menu Screen 4 18 AC Settings Menu Screen 4 20 GEN Support Menu Screen 4 22 Multi Unit Config Menu Screen 4 23 Setting a Device Number 4 26 Adv Features Menu Screen 4 28 View Device Info Log 5 4 Inverter Output Power versus Temperature Derating Graph 6 5 975 0636 01 01 Rev B xiii xiv Tables Table 3 1 Table 3 2 Table 3 3 Table 3 4 Table 4 1 Table 4 2 Table 4 3 Table 4 4 Table 4 5 Table 4 6 Table 4 7 Table 4 8 Table 4 9 Table 4 10 Table 4 11 Table 4 12 Table 4 13 Table 5 1 Table 5 2 Table 5 3 T
3. 6 3 AC Transfer Specifications 6 4 Physical Specifications 6 4 Environmental Specifications 6 4 Regulatory 6 5 975 0636 01 01 Rev B Figures Figure 1 1 Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 3 1 Figure 3 2 Figure 3 3 Figure 3 4 Figure 3 5 Figure 3 6 Figure 3 7 Figure 3 8 Figure 4 1 Figure 4 2 Figure 4 3 Figure 4 4 Figure 4 5 Figure 4 6 Figure 4 7 Figure 4 8 Figure 4 9 Figure 4 10 Figure 4 11 Figure 5 1 Figure 6 1 Materials List 2 2 Re ana DE Rp 1 2 Xanb s System Components 2 2 Conext SW Front and Side Panels 2 4 Front Panel Buttons and Status LEDs 2 5 AC and DC Terminals Network and Communication Ports Panel 2 6 Startup Screen s t csintalan a te ee reis E a 3 9 SCP Top Level Screens 3 10 System Status Jorsen Br gt ass tae ars a eA Ae Ra Shee ed Se as 3 11 Conext SW Home Screen 3 11 Selecting a Device Setup Menu 3 14 Viewing the Meters Screen
4. 4 12 Charger settings Menu k tier RE RE e Re ee i A pue 4 13 Battery Charger Functions 7 7 7 4 15 Multi Stage Charging Process 4 15 Equalize Charging the Batteries 7 7 4 16 Using Charger Block 7 7 7 4 17 Custom Battery Settings Meng vie rss Sc nece uin ete iem Sin er agen dtes 4 18 AG RTL NGS WERE EN ue Dyson EEE ell 4 20 Gen Support Settings pet ar I a I FE THE 4 22 Multi U it Config Mens see seas erect nn aS uoce Gus Idi bc quum 4 23 Setting the Device NIITiges esses esie EHRE suce 4 25 Setting the Device Number ese sse eee eR aue qe nme es 4 26 Restoring Factory Default Settings 77 4 27 Using the Advanced Features ses deemed ee 4 28 Configuration Sheet secs ose meinn nn a idii iE 4 29 Troubleshooting General Troubleshooting Guidelines 5 2 Inverter Applications ass Hi HE e ee tee bs i 5 3 Vew DEVICE Into LOGS 1 eese es sie S pie Stee RASA wee I pfeil UM mts ro BEI 9 4 Troubleshooting the Conext SW via the SCP 9 5 Fault Detection Types 5 a a 5 5 Warming Types sanae PD EE 5 6 Specifications Inverter Specifications 6 2 Charger Specifications
5. Figure 4 11 Adv Features Menu Screen Table 4 13 Adv Features Description and Values Item Description Default Range EuroFreq When enabled sets the Enabled Enabled AC output frequency to Disabled a constant 50Hz a Applies to all Conext SW models The default inverter AC output frequency is 50 Hz To change the inverter AC output frequency to 60 Hz 1 Putthe system in Standby mode See To change an operational setting on page 3 18 2 Change the EuroFreg to Disable See To select and change a configurable setting on page 4 6 NOTICE EQUIPMENT DAMAGE Do not change the frequency to 60 Hz unless the equipment and appliances connected to the inverter s output can operate in this frequency setting Failure to follow these instructions can result in equipment damage 3 Restore the system to Operating mode See To change an operational setting on page 3 18 IMPORTANT Restoring to default see Restoring Factory Default Settings on page 4 27 means that the AC output frequency will change back to 50 Hz 4 28 975 0636 01 01 RevB Configuration Sheet Configuration Sheet SETTING DESCRIPTION DEFAULT YOUR SETTING Inverter Settings Low Batt Cut Out Select battery voltage below which batteries will be cut out 21 0V LBCO Delay
6. Model SW 2524 230 SW 4024 230 Item Default Min Max Default Min Max Batt Type F looded Flooded Gel F looded Flooded Gel AGM Custom AGM Custom Custom Settings See page 4 18 See page 4 18 Batt Capacity See page 4 7 See page 4 7 Max Chg Rate 1007 107 1007 1007 107 1007 Charge Cycle 3Stage 3Stage 3Stage 3Stage 2StgNoF loat 2StgNoF loat Default Batt Warm Hot Warm Cold Warm Hot Warm Cold Temp ReCharge Volts 25 0V 22 0V 27 0 25 0V 22 0V 27 0V Absorb Time 180min 1min 480min 180min 1min 480min Auto Chg Enable Enabled Enabled Enabled Enabled Disabled Disabled Chg Block Start 12 00AM n a 12 00AM n a Chg Block Stop 12 00AM n a 12 00AM n a Configuration via SCP Table 4 6 Charger Settings Menu Description Item Description Batt Type Sets the system battery chemistry and type Flooded AGM Gel and Custom Selecting Custom displays the Custom Settings item which allows you to adjust the settings for each charging stage Custom Settings See page 4 18 Batt Capacity Selects the system battery capacity in amp hours Setting the battery capacity to zero 0 resets the charging current to its default values Zero Ah battery capacity implies there is no absorption exit current criteria and absorption only exits when the absorption timer default 3hrs range 1min 8hr expires Max Chg Rate Same description as Basic Settings on page 4 8 Charge Cyc
7. Fault Warning LED illuminates steadily if a fault is detected a fault detection condition and flashes intermittently when a warning condition is active When AC is present and qualified the AC IN LED will illuminate steadily indicating also that AC is passing through Charging LED flashes intermittently when the Conext SW is in charge mode and is producing DC output to charge your batteries The Inv Enabled LED illuminates steadily when invert mode is enabled If AC is present and invert mode is enabled this LED remains illuminated even though AC power is being passed through Gen Support LED flashes intermittently when the inverter is in generator support mode and is assisting the generator 2 5 Components and Mechanical Features 2 6 Conext SW AC DC Ports Side Panel A DANGER ELECTRICAL SHOCK AND FIRE HAZARD Installation must be done by qualified personnel to ensure compliance with all applicable installation and electrical codes and regulations Instructions for installing the Conext SW are provided in a separate installation guide for use by qualified installers only Failure to follow these instructions will result in death or serious injury Figure 2 4 AC and DC Terminals Network and Communication Ports Panel Item Description 1 Ba
8. Do not cover or obstruct ventilation openings Do not mount in a zero clearance compartment Overheating may result Charge only lead acid batteries e Do not open nor disassemble the inverter charger There are no user serviceable parts inside Do not expose to rain or spray e Disconnect and lockout all AC and DC sources before servicing Servicing includes maintenance or cleaning or working on any circuits connected to the inverter charger See following note Failure to follow these instructions will result in death or serious injury NOTE Turning off inverter mode using the Inv Enable switch on the front panel disabling the inverter and charger functions using the SCP and putting the unit in Standby mode will not reduce an electrical shock hazard Safety A DANGER ELECTRIC SHOCK HAZARD e For indoor use only This inverter charger is designed for off grid solar backup and hybrid applications See the installation guide for information Do not operate the inverter charger if it has been damaged in any way Do not operate the inverter charger with damaged or substandard wiring Wiring must be done by qualified personnel to ensure compliance with all applicable installation codes and regulations Failure to follow these instructions will result in death or serious injury AWARNING EXPLOSION AND FIRE HAZARD e Charge only properly rated such as 24 V lead acid GEL AGM Fl
9. e AC backfeed protection The Battery Temperature Sensor BTS provides these protection features e Battery over temperature charging protection preventing battery charging at 60 C or higher e Charging voltage compensation based on the temperature of the battery the BTS is connected to 1 An AC backfeed error occurs when the AC output of the inverter charger is connected or routed back to the inverter charger s AC input terminal or if the an AC internal transfer relay error is detected 1 6 975 0636 01 01 Rev B Components and Mechanical Features The following topics will be covered in this chapter e System Components e Mechanical Features 975 0636 01 01 RevB 2 1 Components and Mechanical Features System Components Xanbus System xanbus ENABLED 2 2 The Conext SW uses Xanbus a network communications protocol developed to send Conext SW s operational settings and status to other Xanbus enabled devices You can configure and monitor the Conext SW and every Xanbus enabled device in the system using an optional System Control Panel SCP Another component is the optional Automatic Generator Start AGS which allows operation with a wide range of generators supported through a dedicated generator input Simply the AGS automatically starts and stops your generator Solar charge controllers allow renewable energy collected from the sun to charge batteries as might be the case in an off grid application o
10. Fault Detection Types 975 0636 01 01 Rev B There are three types of fault detection messages automatic manual and escalating automatic Table 5 1 describes how they differ in their behavior and how you can respond to them when they appear on the SCP Table 5 1 Fault Detection Types and Behaviors Fault Detection type Behavior Automatic Clears automatically if the fault condition that generated the message goes away You can also acknowledge automatic fault detections without waiting for them to clear automatically Manual Require you to clear them by e pushing the Clear Fault button on the Conext SW or on the device that generated the fault detection if the fault condition still exists the fault detection message reappears and e correcting the condition that caused the fault 5 5 Troubleshooting Warning Types 5 6 Table 5 1 Fault Detection Types and Behaviors Fault Detection type Behavior Escalating automatic Clears automatically if the fault condition goes away just like an automatic fault detection However if an escalating automatic fault detection occurs several times within a defined time period the escalating automatic fault detection becomes a manual fault detection requiring user intervention For example if three fault detections occur in one minute it will no longer clear itself but becomes a manual fault detection Then you must identify the problem correct the fault condition a
11. you can always return to the starting point the System Status screen by pressing Exit repeatedly until the screens stop changing The System Status screen displays e Qualified AC source if applicable and total power to and from the source e Battery capacity and voltage level e Net battery input or output current e Total inverter loading e Time and date System Status Battery 13 8A 24 0V Line 1 Battery input output current and voltage BatLev EEE E F Line 2 Battery level meter Load EEE 1750W Line 3 Power supplied to loads AC In 230V 1750W Line 4 AC input source and line to neutral menu 1 37AM May 11 Voltage Bottom left corner displays AC depending on the active input source The menu arrow indicates the Enter button Press Enter to display the Select Device menu Figure 3 3 System Status Screen The Conext SW Home screen is the first of the Device Home screens Each Conext SW installed in the system has its own Home screen The screen appearance varies with the status of each inverter charger The Conext SW Home screen displays real time operating data specific to the Conext SW The Conext SW status changes according to the states described in Table 3 2 on page 3 12 To display the Conext SW Home screen While viewing the System Status screen press the down arrow key CSW4024E 00 Home Top Line Device name and number lerem acc RG are Line 1 Inverter charger status Battery 16 4A 26 2V Lin
12. INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK AND C REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION THE ACCURACY CANNOT BE GUARANTEED APPROVED CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT WWW SCHNEIDER ELECTRIC COM Document Number 975 0636 01 01 Revision Rev B Date 12 2012 Product Part Numbers 865 2524 61 865 4024 61 Contact Information www schneider electric com For country details please contact your local Schneider Electric Sales Representative or visit the Schneider Electric website at http www schneider electric com sites corporate en support operations local operations local operations page Information About Your System As soon as you open your product record the following information and be sure to keep your proof of purchase Serial Number Product Number Purchased From Purchase Date About This Guide Purpose Scope Audience Organization 975 0636 01 01 RevB The purpose of this Owner s Guide is to provide explanations and procedures for operating troubleshooting and maintaining the Conext SW Inverter Charger The Guide provides safety guidelines as well as information about operating and troubleshooting the unit It does not provide det
13. short or open cells and ensure correct voltage Battery state charge or capacity is so low that the DC voltage collapses when inverter load is applied Inverter load is so large that the DC voltage collapses when inverter load is applied F48 DC Under Voltage Automatic Voltage at the DC Check for the correct battery Fault input terminals is voltage at the inverter s DC below the Low input terminals Battery Cut Out LBCO setting for Check for external DC loads 10 seconds on the batteries Check condition of batteries and recharge if necessary Reduce the Low Battery Cut Out LBCO setting Battery bank capacity may be inadequate for the loads in the system Battery is Charge the battery discharged F49 DC Over Voltage Escalating Auto Voltage at the DC Clear the fault and attempt fault detection input terminals is restart Ensure battery Must occur 3 times above the High voltage is 21 33 VDC default in 30 seconds Battery Cut Out settings at Conext SW before becoming a Setting terminals Check all other manual fault charging source outputs detection battery cables F52 EE ERROR Cal Manual A problem has Clear the fault and check the Fail been detected with latest configuration made or EE ERROR Config the internal any recent configurations If Pati memory fault detection reoccurs or er occurs frequently service is F55 EE ERROR Log required Fail F56 EE ERROR Strings 5 8 Fail 975 0636 01 01
14. to go back to the System Status menu screen To clear fault detections warnings 1 From the device Setup menu screen use the up or down arrow buttons to highlight Clear Faults Warnings 2 Press Enter to clear the highlighted selection 975 0636 01 01 Rev B Configuration via SCP The following topics will be covered in this chapter e Viewing Conext SW s Firmware Version e Setting System Time and Date e Viewing Basic and Advanced Settings e Configuring Basic Settings e Configuring Advanced Settings 975 0636 01 01 Rev B 4 1 Configuration via SCP Viewing the Firmware Revision Number 4 2 You may need to view the firmware revision number F W Rev of the Conext SW when troubleshooting the unit with authorized service personnel To view the firmware revision number 1 From the System Status screen press the Enter button The Select Device menu screen appears From the Select Device screen press the Enter button The System Settings Menu screen appears From the System Settings screen press the down arrow button to highlight View Device Info then press Enter The Device Info screen appears Read the displayed information The series of numbers and letters opposite F W Rev is the firmware revision number Press Exit three times to return to the System Status screen 975 0636 01 01 Rev B Setting the Time and Date Setting the Time and Date 975 0636 01 01 RevB The system time and date
15. Are the configuration settings correct for your particular installation Are the display panel and the communications cable properly connected and undamaged Is the battery temperature sensor and its cable properly connected and undamaged Contact Customer Service for further assistance Please be prepared to describe details of your system installation and provide the model and serial number of the unit See the front and or back of the manual for contact information 975 0636 01 01 Rev B Inverter Applications Inverter Applications Resistive Loads Motor Loads Problem Loads 975 0636 01 01 RevB The Conext SW performs differently depending on the AC loads connected to it If you are having problems with any of your loads read this section Resistive loads are the easiest and most efficient to drive Voltage and current are in phase which means they are in step with one another Resistive loads generate heat in order to accomplish their tasks Toasters coffee pots and incandescent lights are typical resistive loads It is usually impractical to run larger resistive loads such as electric stoves and water heaters from an inverter due to their high current requirements Even though the inverter may be able to accommodate the load the size of battery bank will limit inverter run time Induction motors AC motors without brushes require up to six times their running current on startup The most demanding are those t
16. DC Terminals Network and Communication Ports Panel on page 2 6 2 4 DC battery terminals See AC and DC Terminals Network and Communication Ports Panel on page 2 6 975 0636 01 01 Rev B 975 0636 01 01 RevB Item Conext SW Inverter Charger Mechanical Features Description AC Ground terminals See AC and DC Terminals Network and Communication Ports Panel on page 2 6 AC line terminals See AC and DC Terminals Network and Communication Ports Panel on page 2 6 Manual reset button for the built in 30 amp AC input circuit breaker Two variable speed cooling fans maintain a cool internal temperature of critical components The two fans control airflow through the transformer and power compartments of the unit Ensure at least 250 mm of clearance for proper ventilation Mounting holes for permanent installation n x Inv Enabled AC IN Fault Clear Fault Inv Enable o Pu Gen Support Charging Warning G v Figure 2 3 Front Panel Buttons and Status LEDs Item Description 1 Inv Enable button is used to enable and disable inverter mode Enabled is different from the inverter being on When enabled the inverter can be on or off When disabled the inverter is always off Clear Fault Reset button is used to clear any fault detections if pressed momentarily If held down for more than three seconds the unit will reset reboot itself
17. Features e Basic Protection Features 975 0636 01 01 Rev B 1 1 Introduction Materials List 1 2 Congratulations on your purchase of the Conext SW Inverter Charger called Conext SW The Conext SW has been designed to give you premium true sine wave power ease of use and outstanding reliability for your off grid and power backup applications The Conext SW ships with the following items One Conext SW unit One set of owner s and installation guides One Battery Temperature Sensor BTS Two Xanbus network terminators Two sets of 5 16 18 nuts and washers for the DC terminals Two DC terminal covers red and black with two sets of 446 32 screws One Installation bracket with one set of M6 nuts for mounting not shown NOTE If any of the supplied accessories are missing contact customer service for replacement See Contact Information www schneider electric com on page ii Schneider Figure 1 1 Materials List 975 0636 01 01 Rev B Key Features Key Features The Conext SW Inverter Charger is a true sine wave inverter charger that can be used for off grid backup solar and hybrid applications The Conext SW Inverter Chargers are designed to operate with a wide variety of generators and are capable of operating in parallel with a generator for short durations to assist with starting large loads The Conext SW is a convenie
18. Rev B Table 5 3 Fault Detection Messages Troubleshooting the Conext SW via the SCP Code Message Type Cause Solution F57 FET1 Over Automatic Ambient Ensure adequate ventilation Temperature temperature may around the Conext SW be too high Allow inverter to cool down and try restarting Operating too Remove excessive inverter large of a load for loads too long while inverting Inverter cooling If the temperature is above fan may have 40 C the fan should be on stopped working Hold your hand or a piece of paper to the inverter vent to check if the fan is working Both fans should be active at the same time Inverter airflow Increase the clearance intake may be around the inverter and or blocked unclog the airflow intake vents F58 FETZ Over Automatic Same as F57 Same as F57 Temperature F63 Power Board Temp Automatic Temperature Service required unreadable sensor is damaged F64 AC overload Escalating Auto Persistent Avoid loads with long surge fault detection excessive inverter current Must occur 3 times current above in 60 seconds rated current before becoming a manual fault F68 Transformer Over Automatic Same as F57 Same as F57 Temperature F70 Unique Dev Automatic In a Multi Unit Assign a unique device Needed configuration if number for each unit See To two or more units set the Conext SW device have the same number on page 4 26 device number F
19. amp hours Max Chg Rate Sets the percentage of the maximum DC output current that is available to the charger The maximum DC output current for different models is SW 2524 230 65 ADC SW 4024 230 90 ADC If multiple Conext SWs are charging the same battery bank set each inverter s Max Chg Rate to 1 n of the desired charge rate where n is the number of inverter chargers Charge Cycle Sets the charging method 3 Stage bulk absorption float or 2StgNoF loat bulk absorption no float ReCharge Volts Sets the recharging volts to tell the charger to initiate charging when the battery drains past the value setting AC In Breaker Sets the breaker limit of incoming AC generator or grid Low Batt Cut Out Low Battery Cut Out LBCO controls when the inverter stops producing AC output due to a low battery voltage condition The inverter will stop producing AC output only after this level has been reached for the period of time set by the LBCO Delay This setting is not temperature compensated 4 8 975 0636 01 01 Rev B Configuring Advanced Settings Inverter Settings Menu 975 0636 01 01 RevB Configuring Advanced Settings The Inverter Settings menu contains settings that control when the Conext SW starts and stops producing AC output CSW4024E 00 Adv Charger Settings AC Settings Gen Support Multi Unit Config Restore Defaults Adv Features Inverter Settings Search
20. been reached for this uninterrupted period of time Once the inverter has shut off the battery voltage must rise 4 volts above the Low Batt Cut Out setting for inverter operation to resume 4 9 Configuration via SCP Table 4 4 Inverter Settings Description Item Description Hi Batt Cut Out Hi Batt Cut Out sets the maximum battery voltage at which the inverter will operate If the battery voltage exceeds this limit for more than one minute the Conext SW displays a fault message and shuts down The inverter will not support AC loads when in this condition If a qualified AC source is present the unit passes AC through to the loads The inverter automatically restarts when the voltage drops to 3 volts below the Hi Batt Cut Out setting If battery voltage continues to rise after shutdown an external charger may still be charging the batteries The Conext SW cannot control how external chargers operate Search Watts Search Watts sets the Conext SW s search sensitivity when search mode is enabled When a load larger than this setting is present the inverter starts producing AC output Enabling search mode from the Setup menu can minimize power draw from the battery during periods of low demand from loads Also see Using Search Mode on page 4 11 Search Delay Search Delay sets the time between search pulses When searching for loads the Conext SW sends out search pulses to determine if a load is present If t
21. by function cannot work with clocks and timers or devices that need power 24 hours a day Examples of devices with timers include video recorders coffee makers with brew timers refrigerators and freezers with defrost timers Examples of devices that need power 24 hours a day include telephone answering machines alarm systems motion detection lights and some thermostats e When the inverter is searching the output for loads lights that have a wattage lower than this setting may flash momentarily Using Inverter Block The Inverter Block feature halts inverter function for a period of time each day This period of time is defined by the Inv Block Start and Inv Block Stop settings Inverter Block allows you to control which time period is not ideal for inverting This can be a time period when conserving battery power is more important than running loads The Inverter setting must be initially Enabled in order for the Inverter Block to work as intended The Inv Block Start setting disables inverter function if the inverter is initially enabled and then Inv Block Stop enables the inverter function However if the Inverter setting is initially Disabled when Inv Block Start commences then the succeeding Inv Block Stop will not enable inverter function automatically The inverter will remain disabled Setting the Inv Block Start and Inv Block Stop to the same time disables Inverter Block Disabling Inverter Block means that inverting is al
22. change the settings Figure 4 7 AC Settings Menu Screen Table 4 9 Setting Defaults and Ranges Model SW 2524 230 SW 4024 230 Item Default Min Max Default Min Max ACIn Breaker 30A 5A 30A 30A 5A 30A ACIn Lo Volt 170V 170V 220V 170V 170V 220V ACIn Hi Volt 270V 240V 280V 270V 240V 280V ACIn Lo Freq 45Hz 40Hz 49Hz 45Hz 40Hz 49Hz ACIn Hi Freq 55Hz 51Hz 68Hz 55Hz 51Hz 68Hz AC Qualify Time 5sec 5sec 300sec 5sec 5sec 300sec Table 4 10 AC Settings menu Item Description ACIn Breaker Sets the AC Input breaker size based on the size of the installed AC breaker The breaker size must not exceed the capacity of the AC source such as a generator The Conext SW limits the maximum input current to this setting by derating its charging current If the connected loads exceed the breaker setting the AC breaker trips The breaker may not trip if Gen Support is enabled and Gen Amps is configured not to exceed the generator s rated output current ACIn Lo Volt Sets the minimum acceptable input voltage level from the AC source generator or grid ACIn Hi Volt Sets the maximum acceptable input voltage level from the AC source generator or grid 975 0636 01 01 Rev B Configuring Advanced Settings Table 4 10 AC Settings menu Item Description ACIn Lo Freq Sets the minimum acceptable input frequency from the AC source generator or grid ACIn Hi Freq Sets the maximum a
23. halts charging for a period of time each day This period of time is defined by the Chg Block Start and Chg Block Stop settings In areas where the utility charges variable rates for electricity it is preferable to use utility power for charging only during non peak hours Charger Block can prevent utility power from being used for battery charging during peak billing periods During the time period set between Chg Block Start and Chg Block Stop AC input continues to be passed through to the loads Inverter operation remains unaffected during the charger block period During the Charger Block period no charging occurs even if the batteries discharge below the ReCharge Volts setting However a Solar Charge Controller may charge batteries during the Charger Block period If the charger is operating that is in Float Absorption Bulk or Equalize stage at the Chg Block Start time charging stops immediately and the charger enters an idle state identical to No Float see Two Stage on page 4 16 When the Charger Block period is over the charger does not resume the charge stage that Chg Block Start interrupted Instead if the batteries are above the ReCharge Volts setting the charger remains idle If the battery voltage falls below the ReCharge Volts setting during the Charger Block period the Conext SW Inverter Charger begins a new charge cycle with the Bulk stage after the Charger Block period has expired at the Chg Block Stop time Se
24. is no longer usable the consumer is legally obligated to ensure that it is collected separately under the local electronics recycling and treatment scheme 975 0636 01 01 Rev B Contents Important Safety Instructions 2 3 Precautions When Working With Batteries vii Regulatory viii PMGUCERECCING esent aee eden tater ine seas Se Tse He eR eS as ger eq ein foetus ix Introduction Materials List ass a epe e edu deduce a RE A AH EEE Fa 1 2 Key Fedliles kae wes rn rn a e E E E a ues Re ae E 1 3 Key Features Explained sas ses He ae et a is ees a 1 4 Multiple Unit Configuration esse HER ERS REED Se equite 1 5 Generator Suppbff ssscocSr shinee re a ridet 1 5 Basic Protection earl eG essen 1 6 Components and Mechanical Features System Components Boats HF rex Sains See ee eee eee te 2 2 RENDUSSYSIEHLE SS SH HEERES ER 2 2 Xanbus enabled Products and Other Accessories 2 3 Conext SW Inverter Charger Mechanical Features 2 4 Conext SW Front and Side Panels en Saarel ue affa 2 4 Conext SW AC DC Ports Side Panel es ep ce rer HE ee aces 2 6 Operation Start Up Behavior 3 2 Inverter Operation Using the Front Panel 3 3 Operating Limits for Inverter Operat
25. or the down arrow button to change the value Hold down the button to scroll through a large range of values quickly The previously set value appears with an asterisk beside it Press Enter to select the value 5 If you have another setting to change return to step 1 Or If you have no more settings to change press Exit until the SCP displays the desired screen or menu 4 4 975 0636 01 01 RevB Advanced Settings menu 975 0636 01 01 RevB Viewing the Basic and Advanced Settings Menus The Advanced Settings option gives you access to the full range of Conext SW settings including everything displayed on the Basic menu As a safeguard against unintended Advanced configuration the SCP displays the Basic settings by default To view the Advanced settings you must perform a special keypress NOTICE EQUIPMENT DAMAGE The advanced settings are intended for qualified installation service personnel only Before changing advanced settings you must be familiar with the settings and the system wide impact of changing those settings Setting parameters incorrectly could damage connected equipment such as batteries or could severely affect the performance of your system Incorrect charging configuration can lead to battery damage Failure to follow these instructions can result in equipment damage To select the Advanced Settings menu 1 Onthe Select Device menu select a Conext SW device 2 Press Enter The
26. output drops by 2 amps plus 10 per cent of the GenSup Amps setting for 6 seconds For example if GenSup Amps is set to 10 amps the inverter starts to support when the load exceeds 10 amps for 2 seconds and stops when it drops more than 3 amps below the GenSup Amps setting or 7 amps 2 amps plus 10 per cent of 10 amps 3 amps The system can enter this state if the battery voltage is above the Low Batt Cut Out setting and Gen Support is enabled See Gen Support Settings on page 4 22 Bulk The Conext SW is bulk charging the batteries from qualified AC input from an AC generator or grid AC input is also passed through to the load while bulk charging Absorption The Conext SW is absorption charging the batteries from qualified AC input from an AC generator or grid AC input is also passed through to the load while absorption charging ABS Finish The Conext SW has completed the absorption stage and is waiting for other Conext SWs in the system to complete absorption This status can occur only when there is another Conext SW also charging the battery Equalize Equalization has been turned on and the Conext SW is equalizing the batteries after completing a full charge cycle 975 0636 01 01 Rev B 975 0636 01 01 RevB Inverter Charger Operation using the System Control Panel SCP Table 3 2 Conext SW Home Screen States Conext SW Status Displayed When Float The Conext SW is floa
27. that the BTS uses to adjust the charging voltage when the temperature is above or below 25 C a TheEqlz Voltage setting is displayed when Eqlz Support is set to Enabled NOTE If a warning is received indicating that a setting is not accepted by the SCP gradually increase the value of the setting until the SCP accepts it This type of warning means that an internal minimum threshold value is being crossed and therefore the setting cannot be saved Configuration via SCP AC Settings 4 20 TheAC Settings menu configures the voltage and frequency limits for AC In These are the limits at which the Conext SW considers input voltage qualified that is suitable for charging batteries or powering loads Ifthe input voltage is not qualified according to these settings the Conext SW transfers from using AC input to inverting CSW4024E 00 Adv Inverter Settings Charger Settings Gen Support Multi Unit Config Restore Defaults Adv Features IAC Settings GR ACIn Breaker 30 0Al ACIn Lo Volt 170 0V ACIn Hi Volt 270 0V ACIn Lo Freq 45Hz ACIn Hi Freq 55Hz AC Qualify Time 5sec Ix30Al 5A to 30A 1 pu70 0V1 170 0V to 220 0V 270 0V 240 0V to 280 0V T x45Hz 40Hz to 49Hz ER x55Hz 51Hz to 68Hz Follow procedures on To select and change a configurable setting on page 4 6 to
28. the Inv Enable button on the Conext SW on the front panel The Inv Enabled 6 LED illuminates 2 Turn on the main AC breaker or AC disconnect to supply AC input power to the inverter NOTE The Inv Enabled LED will remain lit However AC will continue to be passed through also called AC bypass to the loads until conditions exist that cause AC to be disqualified in which case the unit will start inverting The AC IN LED should also illuminate The Charging amp LED will start flashing to indicate that the unit is charging the battery The charger automatically starts when qualified AC power is connected and when the battery is not fully charged 3 Turn off the main AC breaker or AC disconnect to stop AC input power from going into the inverter 4 Place aload on the inverter This also usually means turning on the inverter s AC distribution sub panel s breaker switch 5 Connect a load such as a lamp into an outlet connected to the sub panel circuit and turn it on The lamp lights up 6 Repeat step 2 The lamp will remain lit up 7 Repeat step 3 The inverter charger should invert immediately The transfer relay will make a clicking sound and the Inv Enabled 9 LED will illuminate The lamp should remain lit up If any part of this test does not happen correctly determine the cause before continuing to use the unit 8 Monitor the Conext SW front panel The indicator LEDs on the front panel show you the oper
29. the Meters screen and changeable settings Changeable settings are identified by the square brackets around values in the right hand column To display the Setup menu for a device Highlight the device name on the Select Device menu by using the up and down arrow buttons and then press Enter on the highlighted device Or From the Home screen menu simply press Enter Select Device menu Inverter Charger Setup menu Select Device sd CSW4024E 00 Setup System Settings CSW4024E Inverter Enabled Device 2 Search Mode Disabled Device 3 Charger Enabled Device n Force Chg State XW SCP Equalize Disabled Clock Mode Operating Select device from list Clear Faults Warnings View Device Info and then press Enter to Basic Settings jew device Set nu eye NOTE The SCP only displays four lines of the Setup menu at one time To view additional settings press the down arrow button Figure 3 5 Selecting a Device Setup Menu When a particular device is selected it is possible to change its settings and operate the device using the Device Setup menu screen For more information on how to operate the Conext SW see Changing Operational Settings on page 3 16 975 0636 01 01 RevB Meters Screen 975 0636 01 01 RevB Inverter Charger Operation using the System Control Panel SCP The Meters screen displays total system power production generator voltage and current status and load voltage and curren
30. the batteries is a controlled overcharging method that mixes up the electrolyte and reactivates the unused areas of the plate material restoring batteries to a full state of charge Consult the battery manufacturer s recommendation for equalize charging settings To start equalizing the batteries Onthe device Setup menu highlight Equalize and select Enabled NOTE Only flooded or vented batteries should be equalize charged Hydrogen and oxygen gases are produced when batteries are equalize charged See warning below AWARNING EXPLOSION HAZARD Provide adequate ventilation and remove all sources of ignition to prevent explosion Failure to follow these instructions can result in death or serious injury 975 0636 01 01 Rev B Configuring Advanced Settings IMPORTANT In a system where more than one device is capable of equalizing batteries such as a system including multiple Conext SW units and Solar Charge Controllers there is no system wide equalization command for all devices To equalize with multiple devices each would have to be enabled individually Alternatively equalization can be performed using only one device During the equalization process one device applies the equalization charge while the other devices continue to operate in synchronized charge mode typically in float three stage charging or no float two stage charging Using Charger Block The Charger Block feature
31. 0 0 0 0 0 0 0 0 0 0 09 080202020202000009080802020000000002020202000000020202020000000902020 020 000 o cP aP oP 8 00 QUK KUR ORE E oP MoCo ra a SKK KORR QE R KORR REUS 080262020202000009020802020 00000202020202000000020202020900009020202020 o0a e 208900020202000009200062020 000009000202020200090902020202000009290202020 0085 0829000002000000292000020000 009290002020200002929000002000029292900020200 0095 20290902000200002020006000000020295000000200002009020002000020292900020200 0285 080202020202000009090802020000090909020202000009090202020900090902020202000009 20220202020200000909020202020000090902020202000909020202020000090202020200 0o86 OOM aate 000 c eataa agaa o o oae cac a c o o c tcc o o o a e Caco Sen xanbus eider www schneider electric com E ectric Conext SW Inverter Charger Conext SW 2524 230 865 2524 61 Conext SW 4024 230 865 4024 61 Owner s Guide www schneider electric com Copyright 2012 Schneider Electric All Rights Reserved All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies Exclusion for Documentation UNLESS SPECIFICALLY AGREED TO IN WRITING SELLER A MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION B ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES DAMAGES COSTS OR EXPENSES WHETHER SPECIAL DIRECT
32. 0 VAC 170 270 VAC Frequency range 40 70Hz 40 70 Hz AC INPUT Connection Single Phase L N Single Phase L N Supplemental protector resettable 30A 30A 6 3 Specifications AC Transfer Specifications NOTE All transfer specifications are at nominal conditions ambient temperature of 25 C 230 VAC 50 Hz input unless otherwise specified Physical Specifications Environmental Specifications 6 4 SW 2524 230 SW 4024 230 Transfer time utility to invert lt 20 ms lt 20 ms Relay current rating 30 A 30 A Minimum AC input voltage for transfer 170 VAC RMS 170 VAC RMS Maximum AC input voltage for 270 VAC RMS 270 VAC RMS transfer Minimum AC input frequency for 40 Hz 40 Hz transfer Maximum AC input frequency for 70 Hz 70 Hz transfer Cooling Fan cooled Fan cooled temperature temperature controlled controlled SW 2524 230 SW 4024 230 LxWxH 387x343x197 mm 387x343x197 mm Net Weight 28 kg 34 5 kg SW 2524 230 SW 4024 230 Nominal ambient temperature 25 C Operating temperature range 20 to 60 C starts derating above 25 C see following graph Storage temperature range 40 to 85 C Humidity Operation Storage lt 95 RH non condensing Ingress protection rating Indoor only IP 20 Pollution degree Over voltage category AC mains CAT III Altitude Operating 2 000 m Mounting wall mount usin
33. 28 8V 24 0V 32 0V Float Voltage 27 0V 22 0V 32 0V 27 0V 22 0V 32 0V Batt Temp Comp 54mV C 0mV C 90mV C 54mV C 0mV C 90mV C The Custom Battery Settings menu can be viewed if Custom is selected as the Batt Type This menu allows you to adjust charging and equalization voltage for batteries with specifications that fall outside the default settings for the battery types the Conext SW offers You can also adjust the temperature compensation constant for the battery temperature sensor on this menu 975 0636 01 01 Rev B 975 0636 01 01 RevB Configuring Advanced Settings IMPORTANT All settings for configuring a custom battery type are based on the default settings for a flooded battery type Table 4 8 Custom Battery Settings Menu Description Item Description Eqlz Support Enables or disables the ability to enter an equalization cycle Refer to the battery manufacturer s specifications to determine whether equalization is recommended Eqlz Voltage Selects the equalization voltage Consult your battery manufacturer for equalization voltage setting Bulk Voltage Sets the bulk voltage for a custom battery type See note below Absorb Sets the absorption voltage for a custom battery type Voltage Float Sets the float voltage for a custom battery type See note Voltage below Batt Temp Battery temperature compensation for a custom battery type Comp This setting is the coefficient
34. 71 Too Many Masters Automatic In a Multi Unit There can only be one Master configuration if unit Assign the other units as more than one unit Slave See Multi Unit Config is configured as Menu on page 4 23 Master 975 0636 01 01 Rev B 5 9 Troubleshooting Table 5 3 Fault Detection Messages Code Message Type Cause Solution F73 Transformer Temp Automatic Temperature Service required unreadable sensor is damaged F74 Other Unit Automatic In a Multi Unit Clear the primary fault on the Invert Fault configuration if unit that caused this fault to one of the units be detected detects a fault that needs to be resolved F75 Master Inverter Automatic In a Multi Unit Make sure that the two units Lost configuration if are connected in the same the Slave unit Xanbus network Check cannot detect the cable connections and Master unitin the ensure that the plugs are Xanbus network neatly inserted in the ports Check if the Xanbus network is properly installed with network terminators F76 No Masters Automatic In a Multi Unit Assign the other unit as configuration if Master See Multi Unit Config all units are Menu on page 4 23 configured as Slave F79 Battery Sensor Automatic The BTS has been Replace the BTS Short damaged F85 PowerBoard Over Automatic Same as F57 Same as F57 Temperature F87 Inconsistent Automatic In a Multi Unit Configure all units to the Frequencies co
35. Conext SW Inverter Charger onext SW 2524 230 865 2524 61 onext SW 4024 230 865 4024 61 wner s Guide ae DDr X6 Inv Enabled ACIN Fault Clear Fault Inv Enable Gen Support Charging Waming B v A SO WORQRQORAQRRORONOKR KORR ARR 20800820202020202000002020202020000020202020 0000090202020 000009020202020 0a EROR QOO OFEN FON RUNE OR KUNA OUO 20 o oco oO ooo o o0600090009090909090505050505050505090505050505020209000700 08020202020200000902080202000000090202020200000902020202000009090802020200000P 20220262020200000000026202000000090202020200000000020202020000090202020200 oPe 08020202020200009020802020 000002020202020 000902020202030020920202020 00a o SO Be NR NO ON ON 8 2228822 2228020902002030202000205020502030203026200020902090 03e26300e 080220002000000090900020200000009020202020000090960020200000009090202020 0009 002202020202000000090262020 000009020202020 0009090202020200000902020202000 EU 028 0 0 0 0 0 0 0 0 0 0 0 0 0 000 0 0 0 0 0 0 000 0 0 000 000 0 0 0 0 0 0 00000 008 020202020 0 0 020262020 0 0202020202020 0 02020202020 020 020202020 0 0 0 0 gt 822020202000009090262020 0000090802020202000909020202020000090202020200 0o80 080202020202000009090802020 000009090202020900090902020202000009020202020 00a o or x x x OX DARAUS RR d COOKIE QE QR FOE KORR OO QUK OO D ORO 020900 000909090909090965090905090905090505050502050 02020
36. O W for 30 minutes b 4000 W for 30 minutes O W for 30 minutes c 5000 W for 5 seconds 2500 W for 300 seconds d 7000 W for 5 seconds 3500 W for 300 seconds 33 0 V default 6 2 975 0636 01 01 Rev B 975 0636 01 01 RevB Charger Specifications NOTE All charging specifications are at temperature of 25 C 230 VAC 50 Hz in Charger Specifications nominal conditions ambient put unless otherwise specified DC Output SW 2524 230 SW 4024 230 Maximum output current 65 A 90 A Nominal output voltage 24 VDC 24 VDC Charging output voltage operation 12 0 32 0 VDC 12 0 32 0 VDC range Equalization cycle Automatic Manual by SCP Automatic Manual by SCP Optimal charging efficiency 90 90 Dead battery charge voltage gt 12 0 VDC gt 12 0 VDC Charging methods two settings Three stage charge Bulk Absorption Float default Two stage charge Bulk Absorption Without a battery temperature sensor three settings Cool 10 C Warm 25 C default Hot 40 C With a battery temperature sensor provided The temperature compensation coefficients on a 24 volt battery are as follows Flooded 54 mV x 25 C BTS C Gel 54 mV x 25 C BTS C AGM 42 mV x 25 C BTS C AC Input SW 2524 230 SW 4024 230 Power factor at full charge rate 0 98 0 98 Current 10 6A 14A Voltage 230 VAC 230 VAC Voltage range 170 27
37. Restore Defaults fidv Features Follow procedures on To select and change a configurable setting on page 4 6 to change the settings Figure 4 8 GEN Support Menu Screen Table 4 11 GEN Support Menu Description and Values Setting Description Default Range GenSup Mode Turns the generator Disabled Disabled support feature on and Enabled off GenSup Amps Sets the generator load 248 AN 0240 level at which the Conext SW supplies power from the batteries to support the generator a Applies to all Conext SW models The Conext SW supports the generator when the AC load current drawn from the generator exceeds the GenSup Amps setting for one to two seconds The system can enter this state if the battery voltage is above Lou Battery CutOut LBCO plus 1 volt and generator support is enabled 975 0636 01 01 Rev B Multi Unit Config Menu Configuring Advanced Settings TheMulti Unit Config menu configures the Conext SW to operate as a part of a multiple unit installation CSW4024E 00 Adv Inverter Settings Charger Settings AC Settings Gen Support i en Restore Defaults Adv Features Dev Name Dev Number Invtr Mode HouseBatt1 CSW4024E 00 Multi CSW4024E 00 Master Gen1 Master Slave Gen1 Grid1 ExHouseBatt11 HouseBatt5 Follow procedures on To select and change a configurable setting on page 4 6
38. Select the time delay before low battery cut out is engaged 10sec Hi Batt Cut Out Select the voltage above which batteries will be cut out 29 0V Search Watts Select Watts at which level Search Mode triggers on 50H Search Delay Select delay time before Search Mode triggers on 2sec Inv Block Start Sets the time to halt inverting 12 00AM Inv Block Stop Sets the time to resume inverting 12 00AM Charger Settings Batt Type Select your battery type FLOODED GEL AGM etc F looded Custom Settings Makes BATTERY CUSTOM SETTINGS screen visible Eqlz Support Enable battery EQUALIZE function Enabled Eqlz Voltage Select maximum EQUALIZE voltage 32 0V Bulk Voltage Select maximum BULK charge voltage 28 8V Absorb Voltage Select maximum ABSORPTION charge voltage 28 8V Float Voltage Select maximum FLOAT charge voltage 27 0V Batt Temp Comp Select BATTERY TEMPERATURE COMP coefficient 54mV C Batt Capacity Select battery bank capacity 250Ah Max Chg Rate Select maximum charge rate 100 Charge Cycle Select 2 or 3 stage charge cycle 3Stage Default Batt Temp Select system default battery temp setting Warm ReCharge Volts Select voltage at which charger will initiate a charge cycle 25 0V Absorb Time Sets the maximum Absorption time 180min Auto Chg Enable Select automatic charging overrides Charger setup Enabled Chg Block Start Sets the time to halt charging 12 00AM Chg Block Stop Sets the time to resume charging 12 00AM AC Qualify Time Sets charger waiting time 5sec AC
39. Settings AC Breaker Select AC Input current limit 30A AC Lo Volt Select lowest acceptable AC voltage 170V AC Hi Volt Select highest acceptable AC voltage 270V AC Lo Freq Select lowest acceptable AC frequency 45Hz AC Hi Freq Select highest acceptable AC frequency 55Hz Generator Support GenSup Mode Enables Generator Support function Disabled GenSup fimps Generator current level at which Generator Support Starts 24A Multi Unit Config Dev Name Select unique device Name for each unit CSW4024E CSW2524E Dev Number Select unique device number for each unit 00 Invtr Mode Select Master or Slave designation for each unit Master AC In Select AC source type Gen1 Battery Identify batteries HouseBatt1 Restore Defaults Restores all system default settings Advanced Features EuroFreq Sets AC output frequency to 50 Hertz Enabled 975 0636 01 01 Rev B 4 29 4 30 Troubleshooting The following topics will be covered in this chapter e General Troubleshooting Guidelines e Inverter Applications e View Device Info Logs e Troubleshooting the Conext SW via the SCP 975 0636 01 01 Rev B 5 1 Troubleshooting General Troubleshooting Guidelines 5 2 This section will help you narrow down the source of any problem you may encounter Please read the following troubleshooting steps 1 m 100646 Check for a warning or fault detection message on the SCP or a fault code on the inverter information panel If a message is displayed record it i
40. Settings The Conext SW configuration settings can be viewed in Basic and Advanced menu formats The Basic Settings include configuration items you may have to adjust routinely or as part of initial setup The Basic Settings option appears by default on the Setup menu screen The Conext SW Basic settings include menus for configuring e Battery type setting see page 4 7 e Battery capacity setting see page 4 7 e Maximum charging rate setting see page 4 7 e Charging cycle setting see page 4 7 e Charging volts setting see page 4 7 e AC priority setting see page 4 7 e AC Breaker settings see page 4 7 e Low battery cutout setting see page 4 7 To view the Basic Settings menu From the Setup menu scroll to the bottom of the screen to highlight Basic Settings and press Enter See Figure 4 2 CSW4024E 00 Setup CSW4024E 00 Setup CSW4024E 00 Basic Mode Operating F looded Inverter Enabled Clear Faults Marnings Batt Capacity 220Ah Search Mode Disabled View Device Info Max Chg Rate 807 Grid Support Disabled Charge Cycle 3Stage ReCharge Volts 25 0V AC In Breaker 30 06 Low Batt Cut Out 21 0V Figure 4 1 Selecting Basic Settings To select and change a configurable setting 1 Onthe desired configuration menu press the up arrow or down arrow button to highlight the setting you want to change Press Enter to highlight the current value of the setting Press the up arrow
41. Setup menu screen appears 3 Press Enter up arrow down arrow at the same time NOTES e This keypress Enter up arrow down arrow enables the Advanced settings for every device in the system e After performing the keypress Advanced Settings appears at the top of the Setup menu see Figure 4 2 When the keypress is performed again the Setup menu displays Basic Settings as the last item on the menu see Figure 4 1 The Conext SW Advanced settings include menus for configuring e Inverter settings see page 4 9 e Charger settings see page 4 13 e AC transfer limit settings see page 4 20 e Generator support settings see page 4 22 e Multiple unit operation including customizing the default model name of the inverter charger and setting its network device number Setting the device number is important when multiple Conext SW units are on the Xanbus network and sharing connections such as AC loads and AC generator The device number is also used when configuring paralleled Conext SW units for master slave operation see page 4 23 4 5 Configuration via SCP 4 6 Additionally from Conext SW Advanced settings you can e Restore factory defaults e Access other advanced features To view the Advanced Settings menu From the Setup menu with Basic Settings or Advanced Settings highlighted press Enter See Figure 4 2 CSW4024E 00 Setup CSW4024E 00 Adv Advanced Settings Inverter Setting
42. The regulatory maximum for continuous AC loads is 80 of the breaker rating that the loads are connected to The Conext SW senses pass through current going to the AC load The difference between the pass through load and 80 of the Power Share setting is the current that is available for charging the batteries For example ifthe AC input ofthe Conext SW is from an AC panel with a 30 amp breaker the Power Share setting on the SCP should be selected as 30 amp Based on this the charger will control the charge current so that the total current draw is equal to or less than 24 amps in this case Should the load current be more than about 24 amps the charger output will reduce to zero 0 amp but the Conext SW will continue to supply power to the loads The Conext SW will continue to pass through power to the loads even if the load current exceeds the Power Share setting In this case it will be up to the user to remove disconnect loads if tripping the AC input breaker supplying the Conext SW is to be avoided 975 0636 01 01 Rev B Inverter Charger Operation using the System Control Panel SCP Inverter Charger Operation using the System Control Panel SCP This section contains detailed information and procedures for using your Conext SW in conjunction with the SCP If you re using the SCP to operate or monitor the status of the unit you may also refer to the System Control Panel Owner s Guide A WARNING LIMITATIONS ON USE D
43. Watts Search Delay Inv Block Start Inv Block Stop CSH4024E 00 Inv Low Batt Cut Out LBCO Delay Hi Batt Cut Out hh mm AM 21 01 10sec 29 0v 50H 2sec De Bson hh mm AM Ix21 0V 20 0V to 24 0V Ixf sec Losec to 600sec i T 29 0V 21 0V to 33 0V 25H to 250H 1 Sees xZsec 1sec to 25sec Follow procedures on To select and change a configurable setting on page 4 6 to change the settings Figure 4 4 Inverter Settings Menu Screen Table 4 3 Setting Defaults and Ranges Model SW 2524 230 SW 4024 230 Item Default Min Max Default Min Max Low Batt Cut 21 0V 20 0V 24 0V 21 0V 20 0V 24 0V Out LBCO Delay 10sec Osec 600sec 10sec Osec 600sec Hi Batt Cut Out 29 0V 21 0V 33 0V 29 0V 21 0V 33 0V Search Watts 50H 25H 250A 50H 25W 250W Search Delay 2sec 1sec 25sec 2sec 1sec 25sec Inv Block Start 12 00AM n a 12 00AM n a Inv Block Stop 12 00AM n a 12 00AM n a Table 4 4 Inverter Settings Description Item Description Low Batt Cut Out Same description as Basic Settings on page 4 8 LBCO Delay LBCO Delay controls how long the inverter is allowed to operate at or below the Low Batt Cut Out level before turning off due to a low battery voltage condition The inverter will stop producing AC output only after the Low Batt Cut Out level has
44. able 5 4 Front Pane LEDS s ern EEE I HE A 3 4 Conext SW Home Screen States 7 7 3 12 Meters Screen ovs a ee E ERREGER E ETE EEE S 3 15 Conext SWORD ees bs son itt teme es t e Si ae eae 3 17 Setting Defaults and Ranges 4 7 Basic Ellis rese amenities mde IL alan E a epi aie E aie 4 8 Setting Defaults and Ranges HE Crete eae ias mi i eo 4 9 Inverter Settings Description AFFE a se tess Pee ein Fa BEI 4 9 Setting Defaults and Ranges eso seme RA EIE RR eM 4 13 Charger Settings Menu Description 7 7 4 14 Setting Defaults and Ranges rss a a ne 4 18 Custom Battery Settings Menu Description 4 19 Setting Defaults and Ranges ser mer er me a 4 20 AC Settings MERU sane ee ern HS esa 4 20 GEN Support Menu Description and Values 4 22 Multi Unit Menu Description and Values 4 23 Adv Features Description and Values 4 28 Fault Detection Types and Behaviors 5 9 Warning Types and Behavior 7 7 5 6 Fault Detection Messages eee saint EEE TER 9 7 Warning Messages gt 22235 ee 8 11 975 0636 01 01 RevB XV xvi Introduction The following topics will be covered in this chapter e Material List e Key
45. ails about particular brands of batteries You need to consult individual battery manufacturers for this information The Guide is intended for users and operators of the Conext SW Inverter Charger This Guide is organized into the following chapters Chapter 1 Introduction covers material list key features and basic protection features Chapter 2 Components and Mechanical Features provides detailed information on system components and the product s main features Chapter 3 Operation provides operational instructions from the Front Panel including operation using the System Control Panel SCP Chapter 4 Configuration via SCP provides instructions to change inverter and charger settings using the System Control Panel SCP Chapter 5 Troubleshooting covers normal troubleshooting guidelines that also includes fault detection and warning codes and how to interpret them Chapter 6 Specifications covers product specifications About This Guide Conventions Used The following conventions are used in this guide A DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury AWARNING WARNING indicates a potentially hazardous situation which if not avoided can result in death or serious injury A CAUTION CAUTION indicates a potentially hazardous situation which if not avoided can result in mode
46. are set using the SCP Time stamped events such as fault detections and warnings and logged historical data require that the system be set to the correct time The SCP has an internal clock that controls the time for all Xanbus enabled devices in the system You can set the time time format and date on the Clock menu The Clock menu is accessible on the Select Device menu To set the time and date 1 Fromthe System Status screen press the Enter button The Select Device menu Screen appears 2 Fromthe Select Device Screen press the down arrow button to highlight Clock then press Enter The Clock screen appears and Set Time is highlighted 3 Press Enter and use the up and down arrow buttons to change the hour setting 4 Press Enter and use the up and down arrow buttons to change the minute setting 5 Press Enter and use the up and down arrow buttons to select AM or PM This is not applicable if the 12 24 Hour setting is set to 24 6 Press the down arrow button to highlight Set Date 7 Press En setting er and use the up and down arrow buttons to change the month 8 Press Enter and use the up and down arrow buttons to change the day setting 9 Press Enter and use the up and down arrow buttons to change the year setting 10 Press Enter to confirm the changes 11 Press Exit twice to return to the System Status screen 4 3 Configuration via SCP Viewing the Basic and Advanced Settings Menus Basic
47. ating status of the Conext SW A description of the LEDs is provided in Table 3 1 If none of the front panel LEDs are on see General Troubleshooting Guidelines on page 5 2 3 3 Operation Table 3 1 Front Panel LEDs rl Icon LED Status Action or Status Item Steady If generator or grid AC is unavailable You can run your appliances from Ir Green and operating conditions are met the inverter e the Conext SW will produce AC Inv Enabled voltage to power loads Flashing The inverter is assisting a generator You can run your appliances from Gen Support Green in powering loads the inverter E Steady When the Conext SW is connected You can run your appliances using Green to a generator or grid and is passed through AC e producing qualified AC the AC IN AC IN light illuminates Flashing Conext SW is connected to a Your battery bank is being Charging Green qualified AC source is charging and replenished and AC loads are 3 passing through power to AC loads receiving power from a qualified AC aoi E d source Steady A fault has been detected on the Investigate and clear the fault x Red network detection condition o Fault Flashing A warning is detected Investigate by examining warning Warning Red logs on SCP AN 8 4 Fault Detections and Warnings A fault detection condition affects the operation of the unit A fault detection sometimes requires user intervention by cleari
48. cceptable input frequency from the AC source generator or grid AC Qualify Sets the waiting time in seconds before the charger begins Time charging Charging cannot begin until there is qualified AC ACGood so the charger counts from the moment AC is qualified up to the time set in AC Qualify Time before starting to charge 975 0636 01 01 Rev B 4 21 Configuration via SCP Gen Support Settings 4 22 GEN Support allows power to be automatically drawn from the batteries to assist an AC generator to support heavy loads that is loads that exceed the available current from the generator Generators have a limited output current and it is possible to reach this limit when operating heavy loads The Conext SW is designed to assist the generator when heavy current demands load down the generator by supplying additional power from the batteries In addition the battery charger can reduce its charging current to the batteries so the combined charge AC current and total load current does not exceed the capacity of the generator or trip its output breakers or fuses NOTE Running and start up peak currents are limited to the maximum current limits of the inverter CSW4024E 00 Adv CSW4024E 00 Gen Inverter Settings GenSupp Mode Disabled xDisabled or Enabled Gemer Sisi GenSupp Amps 30A AC Settings Ex2401 4A to 24a Gen Support e Multi Unit Config
49. e To change an operational setting on page 3 18 NOTE When changing the operational setting for Charger remember that enabling the charger is not the same as the charger being turned on An enabled charger can either be on or off that is charging or not charging respectively A disabled charger cannot be turned on except when the Auto Chg Enable is set to Enabled See Charger Settings Menu on page 4 13 for details Force Chg State Manually changes the charge stage to either Bulk or Float when 3 Stage cycle is selected or Bulk or NoFloat when 2 Stage cycle is selected See To change an operational setting on page 3 18 Equalize Enables or disables battery equalization See To change an operational setting on page 3 18 Mode Selects the Conext SW operating mode Operating or Standby The red Standby button on the SCP has similar functionality See To change an operational setting on page 3 18 Clear Faults Warnings Clears any active faults that were detected or warnings If the fault detection or warning condition is still present the fault detection or warning message may reappear See To clear fault detections warnings on page 3 18 View Device Info Displays the View Device Info logs screen On the Device Info screen you can view the Warning fault detection and Event Logs See View Device Info Logs on page 5 4 Meters Displa
50. e Flooded x807 _T10z1to 1007 Batt Capacity 2500h Max Chg Rate EBOI x3Stage or 2StgNoF loat Charge Cycle 3Stage ReCharge Volts 25 0V L i Ix25 0V 22 0Vlto 27 0V AC In Breaker 30 08 i Low Batt Cut Out 21 0V urne x30 0Al 5 061to 30 061 FF 555m x21 0V 20 0V to 24 0V Follow procedures on To select and change a configurable setting on page 4 4 to change the settings Figure 4 3 Menu Map of the Conext SW Basic Settings Table 4 1 Setting Defaults and Ranges Model SW 2524 230 SW 4024 230 Item Default Min Max Default Min Max Batt Type Flooded Flooded Gel Flooded Flooded Gel AGM Custom AGM Custom Batt Capacity 250Ah 50Ah 700Ah 250Ah 50Ah 1000Ah Max Chg Rate 1007 10 1007 1007 107 1007 Charge Cycle 3Stage 3Stage 3Stage 3Stage 2StgNoF loat 2StgNoF loat ReCharge Volts 25 0V 22 0V 27 0V 25 0V 22 0V 27 0V AC In Breaker 30A 5A 30A 30A 5A 30A Low Batt Cut 21 0V 20 0V 24 0V 21 0V 20 0V 24 0V Out 975 0636 01 01 Rev B 4 7 Configuration via SCP Table 4 2 Basic Settings Item Description Batt Type Sets the system battery chemistry and type F looded AGM Gel and Custom Selecting Custom displays the Custom Settings item which allows you to adjust the settings for each charging stage Batt Capacity Selects the system battery capacity in
51. e 2 Battery current in or out and voltage Load i 1750N Line 3 Power supplied to loads AC1 0 0V OW Line 4 AC in status setup system The setup arrow indicates the Enter The system arrow indicates the button Press Enter to display the Exit button Press Exit to display inverter charger setup menu the System Home screen Figure 3 4 Conext SW Home Screen Operation 3 12 Pressing the down arrow button from the Conext SW Home screen displays the Home screens for other Conext SW units and other Xanbus enabled devices in the system Table 3 2 Conext SW Home Screen States Conext SW Status Displayed When Invert The Conext SW is supplying power to loads by inverting power from the batteries AC input from the AC generator or grid is absent or out of nominal range Qualifying AC The Conext SW is determining if AC input from the AC generator or grid is within a usable voltage and frequency range It is also displayed when the Conext SW is awaiting application of AC power or a command to enable invert mode GenSupport There is AC input from the generator and the Conext SW is supporting the generator by supplying additional power to the critical loads The Conext SW supports the generator when the AC load current drawn exceeds the GenSup Amps setting for 1 to 2 seconds The Conext SW uses stored DC capacity to load share with the generator until the total AC load current generator plus inverter
52. e the problem after referring to this table contac customer service Table 5 3 Fault Detection Messages Code Message Type Cause Solution F1 AC Output under Escalating Auto Inverter voltage is Remove excessive load voltage fault detection under 202 volts Must occur 3 times in 30 seconds before becoming a manual fault detection F2 AC Output over Escalating Auto Inverter voltage is Check if there is an external voltage fault detection over 260 volts power source that is running Must occur 3 times parallel to the inverter s in 30 seconds output before becoming a manual fault detection F17 AC Backfeed Manual AC backfeed from Service required welded relay F44 Battery Over Automatic Battery Stop charging if necessary Temperature temperature is over 60 C Check cable connections Poor battery Check battery voltage current compartment and temperature If battery is ventilation not accepting charge it may need to be replaced Check for excessive ambient temperature and adequate ventilation in the battery compartment Automatic BTS may be If the unit displays a damaged temperature of over 100 C 975 0636 01 01 Rev B the BTS will need to be replaced 5 7 Troubleshooting Table 5 3 Fault Detection Messages Code Message Type Cause Solution F47 DC Under Voltage Automatic Immediate battery Check battery condition Immediate under voltage fault
53. e used to bring the inverter out of search mode or the inverter may be programmed to remain on by disabling Search Mode See Using Search Mode on page 4 11 Clocks You may notice that your clocks are not accurate Some ofthe clocks on your appliances may reset when the Conext SW is in search mode Searching When the inverter is in search mode it may not start some loads even though the rated wattage on the load is more than the Search Watts setting Disable Search or apply an additional load companion load to make the inverter exit search mode 5 3 Tro ubleshooting View Device Info Logs When troubleshooting it sometimes becomes necessary to look at information logs the Conext SW keeps inside its onboard memory Each log entry is generated automatically when a condition occurs and recorded accordingly in one of the information logs The information logs are organized according to e Warnings CSW4024E 00 Setup Mode StandBy Clear Faults Warnings View Device Info Basic Settings Events Figure 5 1 View Device Info Log 5 4 Fault detections CSW4024E 00 Dev Info View Fault Log View Warning Log View Event Log To view device info logs 64 May 17 11 35AM Fault Log InvChg 64 May 17 5 58AM 47 May 3 3 15AM 76 Time N A 1 From the device Setup menu screen use the up or down arrow buttons to highlight View Device Info Press Enter The De
54. essing the Standby button momentarily affects only Conext SW units it does not affect charge controller operation After disabling inverting and charging with the Standby button the system continues to pass AC input through to the loads Pressing the Exit and Standby buttons at the same time puts the entire Xanbus network system including charge controllers into Standby mode In Standby mode the Conext SW stops passing AC input through to the loads After the keypress command to enter Standby mode the AGS Automatic Generator Start if installed shuts down the generator if it is running after a cool down cycle This section describes the different types of screens and menus on the SCP To monitor Conext SW operation and change settings it is helpful to know how to locate these screens and menus This screen is shown when the SCP first receives power from the Xanbus network Fault Warning O san Schneider Electric Figure 3 1 Startup Screen 3 9 Operation Viewing the SCP Home Screens System Status Screen The top level screens on the SCP are the Startup screen the System Status screen and the Device Home screens After power is applied and the Startup screen appears the SCP displays the System Status screen You can view the Device Home screens for the Conext SW and other devices in the system by pressing the up and down arrows as shown i
55. f Conext SW The charge controllers form part of the Xanbus network See Xanbus enabled Products and Other Accessories on page 2 3 for part numbers The Xanbus system includes the Conext SW and other Xanbus enabled devices The Conext SW is the device in a Xanbus system that typically provides network power 500 mA at 12 VDC All of the Xanbus enabled devices such as the Conext SW the SCP and the AGS are able to communicate their settings and activity to each other Xanbus Network Conex SW EN P P MTS MPPT Solar e Charge N aii C t S Controller TTI AGS an VA i It BT ll EN PEE El I og E d DER SM eee y network terminator S network terminator Figure 2 1 Xanbus System Components The Xanbus enabled designation see left means that this product works on a Xanbus network Xanbus enabled products are e Simple to operate and routine tasks are automated e Controlled by software that eliminates analog signalling errors e Less susceptible to interference and line loss e Upgradable through new software releases For detailed instructions and a complete list of Xanbus enabled devices visit www schneider electric com 975 0636 01 01 Rev B System Components Xanbus enabled Products and Other Accessories
56. g installation bracket 975 0636 01 01 Rev B Regulatory Full power at ambient 3750 SW 4024 230 3500W 3500 IM 3000W 3000 n 2750 2500 SW 2524 230 2500W 2000 c 1750 1500 i 20 10 0 5 10 15 20 25 30 35 40 45 50 55 60 C Figure 6 1 Inverter Output Power versus Temperature Derating Graph NOTE The charger output current does not derate up to 60 C Regulatory All Models Safety CE marked for the Low Voltage Directive 2006 95 EC and RCM marked for Australia and New Zealand per e EC EN 62109 1 Safety of power converters for use in photovoltaic power systems Part 1 General requirements e IEC EN 62109 2 Safety of power converters for use in photovoltaic power systems Part 2 Particular requirements for inverters EMC CE marked for the EMC Directive 2004 108 EC per e EN 61000 6 3 generic residential EMC emissions e EN 61000 6 1 generic residential EMC immunity RCM marked for Australia and New Zealand per e AS NZS 61000 6 3 EMC generic emission standard for residential commercial and light industrial environments 975 0636 01 01 Rev B 6 5 6 6 Index Numerics 2 stage charge mode 16 A ABS Finish 12 Absorption 12 absorption charging stage 15 AC bypass 5 AC settings menu description 20 ACGood 13 Adjustable frequency 3 Advanced menu 5 automatic generator start 11 B battery equalization 16 Battery power 5 battery type 7 13 14 B
57. g the AC qualification frequency range See AC Settings on page 4 20 Temperature controlled variable speed internal cooling fans the fans turn on when the internal temperature reaches 45 C and reaches maximum speed at 70 C The fan turns off when the internal temperature falls to 40 C Xanbus enabled the Conext SW Inverter Charger is also Xanbus enabled which allows network compatibility and communication with other Xanbus enabled devices See more information under Xanbus System on page 2 2 1 In Conext SW Inverter Chargers multiple unit configuration installation is limited to two units one master unit and one slave unit Introduction Key Features Explained Built in Charge Formulas Battery Temperature Sensor Manual Equalization Dead Battery Charging Load Management Multiple Unit Configuration Generator Support For the unit to perform at the highest level the batteries must be charged correctly The Conext SW has optimized algorithms for flooded gel and AGM batteries Since battery temperature is a key factor in correct charging the charging formula must be adjusted automatically and in real time according to the actual battery temperature to ensure that batteries are fully charged but not overcharged For this reason a battery temperature sensor BTS is included with the Conext SW that works with a temperature compensated charge formula Over a period of time the cells in a flo
58. hat start under load for example compressors and pumps Of the capacitor start motors typical in drill presses and band saws for example the largest you can expect to run is 1 horsepower Universal motors are generally easier to start Check that the Locked Rotor Amps LRA rating of the motor load does not exceed the maximum surge current rating of the inverter Since motor characteristics vary only testing will determine whether a specific load can be started and how long it can be run If a motor does not start within a few seconds or loses power after running for a time it should be turned off When the inverter attempts to start a load that is greater than it can handle the inverter may shut down from an AC overload fault Very Small Loads f the power consumed by a device is less than the threshold of the search mode circuitry and search mode is enabled the inverter will not run Most likely the solution will be to disable Search Mode or lower the sense threshold Fluorescent Lights CFL and Power Supplies Some devices cannot be detected when scanned by search mode circuitry Small fluorescent lights are the most common example Some computers and sophisticated electronics have power supplies that do not present a load until line voltage is available When this occurs each unit waits for the other to begin To drive these loads either a small companion load like a light bulb rated for more than the Search Watts setting must b
59. he Conext SW finds a load above the Search Watts setting the inverter turns on Conext SW power draw while in search mode decreases when Search Delay is increased but the Conext SW s response time to active loads is slower Inv Block Start Sets the time to halt inverting See Using Inverter Block on page 4 12 for more information Inv Block Stop Sets the time to resume inverting See Using Inverter Block on page 4 12 for more information 975 0636 01 01 Rev B Configuring Advanced Settings Using the Low Battery Cut Out and LBCO Delay Settings The Low Batt Cut Out setting is the lowest battery voltage level acceptable for use by the inverter When the batteries discharge to the Low Batt Cut Out setting and are held at or below this level for the LBCO Delay time the inverter output shuts down and transfers any available AC source like an AC generator to the charger to bring the battery level back above the Low Batt Cut Out setting After shutdown the inverter does not support any AC loads and AC loads must be powered by an AC generator If using an automatic generator starting system it is recommended to set the Xanbus AGS voltage trigger setting higher than the Conext SW Low Batt Cut Out voltage Otherwise inverter output turns off before the generator automatically starts causing the battery voltage to recover slightly This may then stop the Xanbus AGS from starting the generator or result in the inve
60. ighlight the Conext SW device name and then press Enter 1A 1B System Status CSW4024E 00 Home Battery 13 8A 24 0V Status Invert BatLev EEE E F Battery 16 4A 26 2V Load EEE 1750u Load EEE 1750H AC In 230V 1750W AC1 0 0V 0H menu 1 37AM May 11 wsetup systeme gc p AER fw w m Zw OOOO Oro CT Z YV 6 Iw 2 Select Device CSW4024E 00 Setup System Settings Inverter Enabled Device 2 Search Mode Disabled Device 3 Charger Enabled Device n Force Chg State XW SCP Equalize Disabled Clock Mode Operating Clear Faults Warnings View Device Info Basic Settings Figure 3 7 Navigate To Conext SW Setup Menu 975 0636 01 01 Rev B 975 0636 01 01 RevB Inverter Charger Operation using the System Control Panel SCP Table 3 4 Conext SW Setup menu Menu Item Description Inverter Enables or disables the inverter See To change an operational setting on page 3 18 NOTE When changing the operational setting for Inverter remember that enabling the inverter is not the same as the inverter being turned on An enabled inverter can either be on or off that is inverting or not inverting respectively A disabled inverter cannot be turned on Search Mode Enables or disables Search Mode See To change an operational setting on page 3 18 For more information on this setting see Using Search Mode on page 4 11 Charger Enables or disables the charger Se
61. ion 3 5 Operating Limits for Charger Operation 3 6 Inverter Charger Operation using the System Control Panel SCP 3 7 OUP FEaluies ec nemen mein DB BE I a 3 8 Using the Standby Button 3 9 SCP Navigation 3 9 Startup Screen ee 3 9 Viewing the SCP Home Screens 3 10 Viewing Other Screens 3 14 Changing Operational Settings 3 16 975 0636 01 01 Rev B xi Contents 4 5 6 Xii Configuration via SCP Viewing the Firmware Revision Number 7 7 7 7 7 7 4 2 Setting th Time and Dales are Pieni eed aah ie e eei eu pe a HU d 4 3 Viewing the Basic and Advanced Settings Menus 4 4 COrifig ritig Basic Settings dee aee tease AR dag EHE RER EB ERS HS 4 7 Configuring Advanced SettingS scrres ony pene nn 4 9 Inverter Settings Mehl aee esse ee a ns Seat me 4 9 Using the Low Battery Cut Out and LBCO Delay Settings 4 11 Using Search Mod ser sera tese ee eosdem totidem onc Reale Reon 4 11 Using Inverter Block
62. ions with two paralleled Conext SW units the master unit must have Search mode disabled The slave unit must have Search mode enabled When Search mode is disabled on the master unit and Search mode is enabled on the slave unit only the master Conext SW operates and the slave unit comes online only when the load exceeds approximately 60 of the rated output of the master unit When the load drops below 20 of the master s rated output the slave unit turns off Configuration via SCP When to set up Search mode The Search mode feature is only valuable if the inverter can spend a couple of hours sleeping each day Therefore if Search mode is to be used it must be adjusted properly The initial adjustment should be made so that the inverter comes on only when needed Certain types of loads can cause Search mode not to work as expected These types of loads are described on Problem Loads on page 5 3 of the Troubleshooting chapter If these kinds of loads are in the system follow the suggestions given to eliminate the problem If the problem loads cannot be eliminated there are two work around solutions 1 Disable Search Mode from the main Conext SW Setup menu causing the inverter to always remain at full output voltage 2 Useasearch friendly companion load whose only purpose is to be switched on to wake up the inverter to power the load that is unable to bring the inverter out of Search mode NOTES e Search mode
63. lay status information for each device A device number consists of two digits ranging from 00 default to 31 If only one of each device is installed in the networked power system you do not need to set the device number However setting the device number to a value other than 00 is recommended in case you need to use the Restore Defaults command After performing the command checking that the device number has returned to 00 indicates that the command was successfully completed To set the Conext SW device number 1 Onthe Conext SW Setup menu select Advanced Settings If Basic Settings appears instead of advanced Settings on the Setup menu display Advanced Settings by pressing Enter up arrow down arrow simultaneously On the Advanced Settings menu select Multi Unit Config and then press Enter On the Multi Unit Config menu select Dev Number See Figure 4 10 Press Enter to highlight the instance number Use the up and down arrow buttons to adjust the two digit identifier number Press Enter ak OI CSH4024E 01 Multi Dev Name CSH4024E Dev Number 01 Invtr Mode Slave Battery HouseBatt1 Follow procedures on To select and change a configurable setting on page 4 6 to change the settings Figure 4 10 Setting a Device Number 4 26 975 0636 01 01 Rev B Configuring Advanced Settings Restoring Factory Default Settings 975 0636 01 01 RevB The Restore Defaults command returns the Conext SW t
64. le Sets the charging method 3Stage bulk absorption float or 2StgNoF loat bulk and absorption only no float Default Batt Temp Selects the battery temperature charging compensation if a battery temperature sensor is not installed In the absence of a battery temperature sensor the charger uses one of three settings Cold 5 C Warm 25 C or Hot 40 C ReCharge Volts Sets the recharging volts to tell the charger to initiate charging when the battery drains past the value setting Absorb Time Sets the maximum time spent in the absorption stage before transitioning to float or no float Auto Charge Enable When this setting is enabled it overrides the Charger function to begin charging automatically when qualified AC is present This happens even when the charger function is previously disabled Chg Block Start Sets the time to halt charging See Using Charger Block on page 4 17 for more information Chg Block Stop Sets the time to resume charging See Using Charger Block on page 4 17 for more information 975 0636 01 01 Rev B Configuring Advanced Settings Battery Charger Functions When AC power is available the Conext SW can operate as a battery charger Different battery types and chemistries require different charging voltage levels Not charging batteries at the required levels can shorten battery life or damage the batteries The Conext SW is co
65. lowed to occur at any time when the right conditions for inverting exist NOTE In a multiple unit configuration set the same Inverter Block settings to both the master and slave units 975 0636 01 01 RevB Charger Settings Menu 975 0636 01 01 RevB Configuring Advanced Settings The Charger Settings menu provides options for configuring the Conext SW to operate from your battery bank CSW4024E 00 Adv CSW4024E 00 Chg Batt Type Custom Settings Batt Capacity Inverter Settings pirates J AC Settings Gen Support Multi Unit Config Restore Defaults Adv Features 1007 3 Stage Harm Max Chg Rate Charge Cycle Default Batt Temp ReCharge Volts fibsorb Time fiuto Chg Enable Chg Block Start hh mm AM hh mm AM Chg Block Stop F looded 250Ah J 25 0V 1 180minl Enabled l ee d dessen Gel AGM Custom x250Ah 50Ah to 2000Ah 18021 171 to 100x 3 Stage or 2StgNoF loat Peete ee xWarm Hot Cold 22 0V to 27 0V t iM T 25 0v1 I Tx180nin imin to 480min TxEnabled or Disabled Follow procedures on To select and change a configurable setting on page 4 6 to change the settings Figure 4 5 Charger Settings Menu Screen Table 4 5 Setting Defaults and Ranges
66. mmediately As soon as possible record the conditions at the time the problem occurred These details should include the following as well as any other information asked for on the page These details are e Firmware revision of the Conext SW e Type of loads the Conext SW was running or attempting to run e Battery condition at the time of fault detection battery voltage or temperature for example if known e Recent sequence of events for example charging had just finished AC generator had stopped but the inverter did not come on e Any known unusual AC input factors such as low voltage or unstable generator output e Extreme conditions which may have existed at the time temperature or moisture for example Attempt the solution indicated in these guidelines If your inverter front panel or SCP is not displaying a Fault detection light check the following list to make sure that the present state of the installation allows proper operation of the unit Read these guidelines carefully Is the Conext SW located in a clean dry adequately ventilated area Have the AC input breakers opened If so your pass through load may have exceeded the rating of one or more of the input breakers Are the battery cables adequately sized and short enough See the Installation Guide for more information Is the battery in good condition and are all DC connections tight Are the AC input and output connections and wiring in good condition
67. n Figure 3 2 Appears for a few seconds after the system starts Schneider up or when the system has been reset Startup Screen Press Enter to view Select Device menu Select device from list and press Enter to view System Status Select Device f Screen Screen device Setup menu 5 Inverter Charger Home Screen Device 2 Home Screen Press Enter from a Device Home screen v to view the Device Setup menu Device 3 Home Screen The number of Home screens depends on the number of Xanbus enabled devices installed in the system Device n Home Screen Figure 3 2 SCP Top Level Screens The System Status screen appears after the Startup screen The System Status screen displays aggregated status information for the entire power system For example a single system may have three Xanbus network connected Conext SWs two MPPT Solar Charge Controllers one AGS Automatic Generator Start module and one SCP System Control Panel all connected to a single battery bank and a single AC generator The System Status screen always features a Menu arrow pointing to the Enter button Pressing Enter takes you to the Select Device menu 975 0636 01 01 Rev B Conext SW Home Screen 975 0636 01 01 RevB Inverter Charger Operation using the System Control Panel SCP IMPORTANT If you are uncertain which SCP screen or menu you are viewing
68. nd clear the fault detection or reset the device To view a list of the detected faults 1 Onthe Select Device menu highlight System and press Enter 2 Onthe System Settings menu highlight View Fault List 3 Press Enter There are two types of warnings automatic and manual When the Conext SW detects a warning condition it displays a warning message on the SCP Table 5 2 describes how they differ in their behavior and in how you can respond to them when they appear on the SCP Table 5 2 Warning Types and Behavior Warning type Behavior Automatic warning Clears automatically if the warning condition that generated the message goes away You can also acknowledge automatic warnings without waiting for them to clear automatically Manual warning Requires you to acknowledge it before you can proceed with configuring or operating the Conext SW Manual warnings are usually in the form of a Yes No question that you may acknowledge by pressing the Enter button on the SCP for Yes and the Exit button for No Refer to the System Control Panel Owner s Guide for more information To view a warning list 1 Onthe Select Device menu highlight System and press Enter 2 Onthe System Settings menu highlight View Warning List 3 Press Enter 975 0636 01 01 Rev B Troubleshooting the Conext SW via the SCP Table 5 3 provides a detailed description of the fault detection messages and solutions If you are unable to resolv
69. nfiguration if same AC output frequency all units are not See Using the Advanced configured to the Features on page 4 28 same AC output frequency F88 MPPT Ground Automatic In a Xanbus Check the MPPT and clear Fault network an MPPT the ground fault F56 has detected a ground fault F56 F93 Wrong Batt Automatic An unknowns BTS Use only the BTS that was Temperature was plugged into provided with the Conext SW Sensor the BTS port Inverter Charger To order use product number 808 0232 02 975 0636 01 01 Rev B Troubleshooting the Conext SW via the SCP Table 5 4 provides a detailed description of the warning messages and solutions If you are unable to resolve the problem after referring to this table contact customer service Table 5 4 Warning Messages Code Message Fault Type Cause Solution W48 DC under voltage Automatic Voltage atthe DC Check for the correct battery Warning input terminals is voltage at the inverter s DC below the Low input terminals Battery Cut Out LBCO setting Check for external DC loads on the batteries Check condition of batteries and recharge if necessary Reduce the Low Battery Cut Out LBCO setting Battery bank capacity may be inadequate for the loads in the system W69 AGS not Automatic The GenSup Mode Install an AGS on the network connected setting is enabled or disable the GenSup Mode but there is no setting AGS connected in the Xanbus ne
70. nfigured at the factory to work with the battery types recommended for inverter applications Ifthe default settings do not work for your specific installation you can adjust the charge stage settings as recommended by the battery manufacturer on the Custom Battery Settings menu see page 4 18 IMPORTANT This information is provided for guidance only Variations in battery chemistry and site specific environmental considerations mean that you should consult your system designer or battery manufacturer for specific recommendations for appropriate battery voltage and current settings Multi Stage Charging Process Bulk Stage Absorption Stage 975 0636 01 01 RevB The charging cycle is a multi stage process Whenever qualified AC power is present at the inverter s input it passes power through to the connected load and begins charging the batteries NOTE Ifthe AC input fails or drops below the lower VAC limit as set in AC Settings the complete multi stage charge cycle Bulk Absorption Float No Float restarts once the source AC returns to within tolerance condition If the batteries are already nearly full the charge cycle will take little time to complete Bulk charge is the first stage in the charging process and provides the batteries with a controlled constant current Once the battery voltage rises to the bulk voltage threshold the charger switches to the Absorption stage Absorption charge is the second s
71. ng is selected the charger automatically switches to the float stage after the batteries have received a bulk and absorption charge The batteries will be maintained at the default float voltage level for the selected battery type or the voltage selected under Float Voltage on the custom battery Settings menu NOTE The battery voltage can increase above the float voltage when using an external charging device such as PV arrays wind turbines or micro hydro generators Be sure to include appropriate charge management equipment with all external DC sources Two stage bulk and absorption only no float mode differs from an ordinary three stage charge mode in that it does not continuously maintain the battery at float voltage Instead the Conext SW begins charging the battery in bulk mode whenever the battery voltage drops below the recharge level While the battery voltage is above the recharge level the inverter continues to pass power through from the AC source to the loads but does not actively charge the batteries Equalize Charging the Batteries Many battery manufacturers recommend periodic equalize charging to level out the voltage between individual cells improving battery performance and lifespan Over time the battery s electrolyte can become stratified causing inactive areas in the plate material If this condition is allowed to continue for extended periods the battery plates can sulfate and become unusable Equalizing
72. ng the condition using the Clear Fault button on the inverter charger s front panel Press the button once to clear the condition See Troubleshooting on page 5 1 for information on clearing fault detections from the SCP A warning alerts you to a condition that could possibly affect operation of the unit A warning usually precedes a fault detection condition IMPORTANT If you are having problems with any of your loads refer to Inverter Applications on page 5 3 975 0636 01 01 Rev B Inverter Operation Using the Front Panel Operating Limits for Inverter Operation 975 0636 01 01 RevB Temperature The Conext SW series of inverter chargers will operate at rated power continuously at 25 C with some models capable of continuous operation at much higher ambient temperature However the continuous power rating at elevated ambient temperature may differ between models See Environmental Specifications on page 6 4 for full details In higher ambient temperatures ifthe loads draw full power for an extended period of time the unit may shut down to protect itself against overheating Surge Power The Conext SW series of inverter chargers feature a surge rating of 200 of rated power for five seconds at 25 C See Inverter Specifications on page 6 2 for full details Operating the inverter charger in conditions outside of normal rated power and temperature limits however will result in thermal shutdown and or significan
73. nt combination of an inverter multi stage battery charger and transfer switch in one electronic device The Conext SW Inverter Charger s key features are 975 0636 01 01 Rev B True Sine Wave output as an inverter the Conext SW provides true sine wave power for your microwave entertainment system computer and other loads This power is identical to the AC source provided from the utility grid power company Some of the benefits of high efficiency true sine wave power include consistent cooking in your microwave handling of sensitive loads such as your TV set dimmer switches and appliances with speed controls Multiple unit configuration the Conext SW Inverter Charger has a highly versatile platform capable of parallel multiple unit configuration to increase power levels High surge capacity the Conext SW Inverter Charger has a surge rating that is twice the maximum continuous output power rating to start difficult loads like well pumps refrigerators or A C compressors See Inverter Specifications on page 6 2 Power factor correction Power factor corrected PFC input minimizes AC input current required for charging increasing AC pass through capacity Multi stage charging the Conext SW Inverter Charger has a high output multi stage charging capability that minimizes charging time Adjustable frequency the Conext SW Inverter Charger is capable of operating from a 50Hz and 60Hz power source by extendin
74. o factory default settings After using the Restore Defaults command the Conext SW is no longer configured for the power system NOTICE EQUIPMENT DAMAGE Do not use the Restore Defaults command while the Conext SW is operating De energize the power system and disconnect the Conext SW AC input before using the Restore Defaults command Reconfigure the Conext SW before reconnecting the AC input and re energizing the power system Failure to follow these instructions can damage the inverter charger To restore Conext SW default settings 1 Onthe Advanced Setup menu select Restore Defaults Warning W252 appears asking to confirm the Restore Defaults command 2 To cancel the command press Exit To continue with the Restore Defaults command press Enter IMPORTANT If a warning is already active in the system selecting Restore Defaults brings up the Warning List with warning W252 at the top Press Enter to view W252 and continue with the Restore Defaults process IMPORTANT Restoring to default also means that the AC output frequency will change back to 50 Hz See Using the Advanced Features on page 4 28 for information on changing the AC output frequency to 60 Hz 4 27 Configuration via SCP Using the Advanced Features CSW4024E 00 Adv Fea EuroFreq Enabled xEnabled Disabled Follow procedures on To select and change a configurable setting on page 4 6 to change the settings
75. o not use in connection with life support systems or other medical equipment Failure to follow these instructions can result in death or serious injury The SCP provides operating configuring and monitoring capability for your Xanbus system The System Control Panel e Monitors activity throughout your power system e Displays the latest information about your inverter charger battery voltage level battery charge output and generator start and stop activity e Displays the settings for each Xanbus enabled device in the system e Enables you to adjust the settings for each Xanbus enabled device in the system e Preserves all of its settings if system power is interrupted After power is restored you don t have to reconfigure the SCP or any of the Xanbus enabled devices connected to it The SCP provides remote configuration and monitoring capabilities for the Conext SW and other Xanbus enabled devices in the power system Please refer to the System Control Panel Owner s Guide for complete information on using the System Control Panel You can monitor Conext SW operation on the SCP using the e System Status screen see page 3 10 e Conext SW Home screen see page 3 11 e Conext SW Meters Menu see page 3 15 975 0636 01 01 RevB 3 7 Operation SCP Features FaultWarpips O pee rl Standby 1 Schneider i 6 c DWG Feature Description 1 Fault Wa
76. oded battery can develop uneven chemical states This can result in aweak undercharged cell which in turn can reduce the overall capacity of the battery To improve the life and performance of a non sealed flooded battery the Conext SW s multi stage charging cycle includes a manual equalize mode that can be used if recommended by the battery manufacturer Another feature that the Conext SW includes is dead battery charging The Conext SW unlike many chargers has the ability to recharge batteries even if the battery voltage is very low that is as low as 12 volts The Conext SW has a built in transfer relay that connects your inverter output or AC input from the AC generator to your loads Because the usual AC power sources such as small generators often have limited current availability having the capability to manage your AC loads is extremely valuable The Conext SW provides a number of features to facilitate this e The charger is power factor corrected to use AC current as efficiently as possible Minimizing the AC current used by the charger means more current is available for your AC loads e The Conext SW has a power share feature which prioritizes your AC loads by reducing the charge current and maintaining the total input current to less than the breaker setting Occasionally AC input sources have low voltage To avoid loading these weak sources any further the charger automatically reduces its AC current draw as the AC
77. ooded or lead calcium rechargeable batteries because other battery types may explode Do not work in the vicinity of lead acid batteries Batteries generate explosive gases during normal operation See note 1 Do not install and or operate in compartments containing flammable materials or in locations that require ignition protected equipment See notes 2 and 3 Failure to follow these instructions can result in death or serious injury NOTES 1 Follow these instructions and those published by the battery manufacturer and the manufacturer of any equipment you intend to use in the vicinity of the battery Review cautionary markings on these products 2 This inverter charger contains components which tend to produce arcs or sparks 3 Locations include any space containing gasoline powered machinery like a generator fuel tanks as well as joints fittings or other connections between components of the fuel system A CAUTION FIRE AND BURN HAZARD Do not cover or obstruct the air intake vent openings and or install in a zero clearance compartment Failure to follow these instructions can result in moderate or minor injury vi 975 0636 01 01 Rev B Safety Precautions When Working With Batteries Important Battery work and maintenance must be done or supervised by qualified personnel knowledgeable about batteries to ensure compliance with battery handling and maintenance safety precau
78. r disable the inverter A separate control device called a System Control Panel or SCP may also be used to enable or disable the inverter However the unit will remember its inverter function setting in succeeding operations This means that if the inverter function is left enabled before a reset or power down power up cycle the inverter function will remain enabled When a function is enabled it generally means that it is standing by and other conditions may have to be met before the function is utilized For example the charger function on the Conext SW may be enabled but it will not charge unless qualified AC power is present Similarly even if the inverter function is enabled inverting may not occur if the batteries cannot supply the energy required for the loads IMPORTANT Review the Important Safety Instructions on page v before operating the inverter charger 975 0636 01 01 Rev B Inverter Operation Using the Front Panel Inverter Operation Using the Front Panel 975 0636 01 01 RevB IMPORTANT Review the Important Safety Instructions on page v before operating the inverter charger Once the inverter charger is installed you can operate it in invert mode The steps below will test the unit for normal operation using the front panel PA X Inv Enabled AC IN Fault Clear Fault Inv Enable e e p Gen Support Charging Warning iS va A To test the inverter using the front panel 1 Press
79. rate or minor injury NOTICE NOTICE indicates a potentially hazardous situation which if not avoided can result in equipment damage Abbreviations Acronyms and Symbols AC Alternating Current LED Light Emitting Diode AGS Automatic Generator Start SCP System Control Panel BOS Balance of System SW Sine Wave DC Direct Current VAC Volts Alternating Current PPE Personal Protective VDC Volts Direct Current Equipment PV Photovoltaic Earth Related Information You can find more information about Schneider Electric as well as its products and services at www schneider electric com iv 975 0636 01 01 Rev B Important Safety Instructions READ AND SAVE THESE INSTRUCTIONS DO NOT DISCARD 975 0636 01 01 RevB A DANGER ELECTRICAL SHOCK AND FIRE HAZARD Installation must be done by qualified personnel to ensure compliance with all applicable installation and electrical codes and regulations Instructions for installing the Conext SW are provided in a separate installation guide for use by qualified installers only Failure to follow these instructions will result in death or serious injury A DANGER ELECTRICAL SHOCK AND FIRE HAZARD e Read all instructions cautionary markings and all other appropriate sections of this guide before operating troubleshooting and performing maintenance on the Conext SW e Exercise extreme caution at all times to prevent accidents
80. removing cell caps while charging whether equalization is acceptable for your battery and recommended rates of charge Failure to follow these instructions can result in moderate or minor injury NOTICE RISK OF INVERTER CHARGER DAMAGE Never place the Conext SW Inverter Charger unit directly above batteries gases from a battery will corrode and damage the inverter charger Failure to follow these instructions can result in damage to equipment The Conext SW Inverter Charger is certified to appropriate European Australian and New Zealand standards For more information see Regulatory Approvals under Specifications The Conext SW Inverter Charger is intended to be used for off grid backup solar and hybrid applications It is not intended for other applications as it may not comply with the additional safety code requirements needed for those other applications See Limitations On Use below A WARNING LIMITATIONS ON USE Do not use in connection with life support systems or other medical equipment Failure to follow these instructions can result in death or serious injury 975 0636 01 01 Rev B Safety Product Recycling AL Do not dispose of this product with general household waste Electrical appliances marked with the symbol shown must be professionally treated to recover reuse and recycle materials in order to reduce negative environmental impact When the product
81. rning light indicates a device has a fault detection or warning condition and requires attention The light flashes when a warning occurs and turns on steadily when a fault detection occurs 2 Enter button confirms selection of a menu item or displays the next Screen 3 Up arrow button scrolls upward through screen text or increases a selected value 4 Down arrow button scrolls downward through screen text or decreases a selected value 5 Exit button cancels selection of a menu item or displays the previous Screen 6 Screen shows menus settings and system information 7 Standby button disables inverting and charging on all Conext SW units in the system when pressed and held for one to two seconds To enable inverting and charging press and hold the Standby button again for one to two seconds 3 8 975 0636 01 01 Rev B Inverter Charger Operation using the System Control Panel SCP Using the Standby Button SCP Navigation Startup Screen 975 0636 01 01 RevB The Standby button has two functions depending on how it is pressed First when only the Standby button is pressed it can disable inverting and charging for all Conext SW units in the system Second when it is pressed simultaneously with the Exit button this action puts the entire system into Standby mode Pressing the Standby button produces the same result as disabling Invert and AC Charge from the System Settings menu on the SCP Pr
82. rter cycling on and off multiple times before the generator automatically starts If using an automatic generator starting system with the start trigger set to the same voltage as the LBCO voltage do not set the LBCO Delay for less than the amount of time it takes the generator to start and connect Otherwise inverter output turns off before the generator automatically starts causing the battery voltage to recover slightly This may then stop the Xanbus AGS from starting the generator or result in the inverter cycling on and off multiple times before the generator automatically starts Using Search Mode Why use Search mode Single units Multiple units 975 0636 01 01 Rev B Search mode allows the inverter to selectively power only items that draw more than a certain amount of power which can result in power savings The Conext SW has a no load power draw of about 38 W SW 2524 230 and 40 W SW 4024 230 Enabling Search mode reduces this power draw to less than 8 W for all models Search mode operates differently in single unit and multiple unit installations When a single Conext SW has Search mode enabled the inverter sends electrical search pulses through its AC output These search pulses search for connected AC loads The delay between search pulses is set using the Search Delay setting After a load larger than the Search Watts setting is detected the inverter turns on To use Search mode in multiple unit installat
83. s Meters Charger Settings Inverter Disabled AC Settings Search Mode Disabled Gen Support Multi Unit Config Restore Defaults Adv Features Figure 4 2 Selecting Advanced Settings To select and change a configurable setting 1 On the desired configuration menu press the up arrow or down arrow button to highlight the setting you want to change Press Enter to highlight the current value of the setting Press the up arrow or the down arrow button to change the value Hold down the button to scroll through a large range of values quickly The previously set value appears with an asterisk beside it Press Enter to select the value 5 Ifyou have another setting to change return to step 1 Or If you have no more settings to change press Exit until the SCP displays the desired screen or menu IMPORTANT If you have no more settings to change it is recommended to leave the Setup menu in the Basic Settings format to help prevent unintended configuration Ifthe Setup menu displays Advanced Settings press Enter up arrow down arrow atthe same time The Setup menu should then display Basic Settings as the last item on the menu 975 0636 01 01 Rev B Configuring Basic Settings Configuring Basic Settings An overview of the Conext SW Basic Settings menu structure is shown below aa xFlooded Gel AGM Custom NETTE bp x250ah 50Ah to 20008h Batt Tup
84. t charging the batteries from qualified AC input from an AC generator or grid The Conext SW is set for three stage charging AC input is also passed through to the load while float charging NoF loat The Conext SW finishes the absorption stage and the Conext SW is set for two stage charging ACGood The Conext SW has determined that AC input is within a usable voltage and frequency range LdSenseActv Search Mode is enabled and the Conext SW is standing by waiting to begin inverting See Using Search Mode on page 4 11 Operation Viewing Other Screens Select Device Menu Device Setup Menus 3 14 This section describes the next level of screens and menus on the SCP The Select Device menu displays a list of Xanbus enabled devices in the system including the Conext SW and the SCP The Select Device menu is where you can access the Setup menus for each device in the system The length ofthe Select Device menu depends on how many Xanbus enabled devices are installed The Select Device menu also contains the Clock menu where the time and date are set and the System Settings menu where system level settings can be configured The System Settings SCP and Clock menus are always available from the Select Device menu regardless of the number of Xanbus enabled devices installed To display the Select Device menu While viewing the System Status screen press Enter Device Setup menus display status information on
85. t stages Each unit charges batteries based on the Max Charge Rate setting and active internal temperature based deratings If equalization is enabled on one or more devices capable of equalization charging only those devices perform an equalize cycle after absorption Other devices transition to float if three stage charging is selected or transition to AC pass through if two stage charging is selected Generator Support The Conext SW inverter chargers can operate in tandem with an AC generator to temporarily assist power loads with large start up demands such as air conditioners and water pumps An Automatic Generator Start device AGS must be installed in the system in order for this feature to work When this mode is enabled and generator capacity defined the inverter will come on line and assist the generator when the generator reaches its capacity The battery bank must be well charged in order for the inverter to engage this mode For more details see Gen Support Settings on page 4 22 975 0636 01 01 Rev B 1 5 Introduction Basic Protection Features The Conext SW has the following protection features e Over temperature shutdown for critical components such as the transformer and the power board e Battery temperature sensor BTS failure battery temperature out of range fault protection e DC output over voltage protection during charge mode e AC output overload and short circuit protection during invert mode
86. t status To view the Meters screen On the Conext SW Setup menu highlight Meters and then press Enter Figure 3 6 Viewing the Meters Screen Table 3 3 Meters Screen CSW4024E 00 Setup CSN4024E 00 Meters Mode ACGood Inverter Enabled Battery 23 9V 0 0A N A Search Mode Disabled Load 4504 230V 1 8A Charger Enabled AC In 1 6A 231V 50Hz Force Chg State Equalize Disabled Mode Operating Clear Faults Warnings View Device Info Basic Settings Screen Item Description Mode Operating state of the Conext SW See also Conext SW Home Screen States on page 3 12 Battery Displays battery voltage charging current and battery temperature The battery temperature comes from the BTS connected to the Conext SW If the BTS is not installed Battery shows as N A that is not available Load Displays power consumption watts voltage volts and current amps supplied to the AC loads AC In AC input current voltage and frequency connected to the Conext SW AC INPUT L terminal Operation Changing Operational Settings The following table shows the various settings you can change to effectively operate the Conext SW inverter charger To navigate to the Conext SW Setup menu 1 From the System Status Screen see 1A press Enter to view the Select Device menu Go to step 2 Or From the Conext SW Home screen see1B press Enter The Conext SW Setup menu appears 2 H
87. tage of battery charging and provides the batteries with a controlled constant voltage During this stage the current drawn by the batteries slowly decreases When this current falls below 2 of the battery capacity or when the configurable Absorb Time expires the charger switches to the Float or NoFloat stage depending on the selected charge cycle NOTE If there are DC loads on the batteries the charger s current may never decrease to a level to initiate the next stage of charging In this case the charger would stay in absorption until the Absorb Time setting is reached To make sure the charger does not remain in absorption for too long adjust Absorb Time on the Charger Settings menu The timer begins at the start of the absorption stage and terminates absorption charging if the charge current does not decrease to below 2 of the battery capacity before the Absorb Time setting expires The Absorb Time setting may be increased if the charge cycle continually runs the full Absorb Time in the absence of DC loads This is an indication of too large a battery bank for the selected Absorb Time setting Configuration via SCP Float Stage Two Stage Float charge maintains a trickle charge on the batteries whenever AC is present on the Conext SW input Float charging reduces battery gassing minimizes watering requirements for flooded batteries and makes sure the batteries are in a constant state of readiness When three stage chargi
88. te the inverter charger with an AC source before a DC source like the battery Do not rely solely on AC bypass power to provide energy to connected loads Always operate with a battery connected to the inverter charger Failure to follow these instructions can damage the inverter charger 3 5 Operation Operating Limits for Charger Operation 3 6 By default the maximum charger output current is the rated charger output current for the particular model Using the SCP you can reduce the total output if you change the maximum charge rate Max Chg Rate on the Conext SW Basic Settings menu or Inverter Settings menu under Advanced Settings The charger can charge batteries when the AC input voltage is within the minimum and maximum range of 170 to 270 VAC They are the default minimum and maximum settings The minimum range setting can be adjusted from 170 to 220 VAC and the maximum range setting from 240 to 270 VAC The charger can also be configured to accept and operate from a wide AC source frequency of between 40 to 70 Hz The default range setting is between 45 to 55 Hz This wide range allows the Conext SW to charge your batteries even when incoming AC voltage becomes less than the typical 50 Hz Power Share The Conext SW charger uses AC INPUT L to charge the batteries The AC loads have priority which means that the charger will reduce its output with large AC loads and increase the output again when the AC load decreases
89. the type Gent Geni Grid of AC source when two power sources are available and an AGS is also present Battery For identifying batteries HouseBatt1 HouseBatt1 only HouseBatt5 a Applies to all Conext SW models When installing a multiple unit system every setting on the Multi Unit Config menu except for Dev Name must be configured for each Conext SW in the system The settings should be configured in the following order Dev Number then Invtr Mode The Conext SW accepts only a single AC source either from the grid or from a generator In a power system where the Conext SW is solely connected to the grid and an AGS is neither present nor required the AC In setting can be either Gen1 or Grid1 Therefore the default value of Gen1 need not be changed In a situation where the AC source is a generator and the AGS is being used to start the generator to produce AC power the AC In setting must be set to Gent Therefore the default value of Gen1 must remain unchanged In a power system where the two AC sources are available but only one AC source can be used an external transfer switch becomes necessary When an external transfer switch is used and an AGS with a B signal connection is also present change the AC In setting to Grid1 975 0636 01 01 Rev B Configuring Advanced Settings Setting the Device Name The Dev Name setting allows you to customize the name of the Conext SW as it is displayed on o
90. ther screens and menus The available characters are AtoZ atoz Oto9 space NOTE Increasing the number of characters in a device name may cause other text on the same line to run off the edge of the screen Device names should be limited to 10 characters or less To customize the Conext SW name 1 975 0636 01 01 Rev B On the device setup menu select Advanced Settings If Basic Settings appears instead of Advanced Settings on the Setup menu display Advanced Settings by pressing Enter up arrow down arrow simultaneously On the Advanced Settings menu select Multi Unit Config and then press Enter Select Dev Name and then press Enter The last letter of the Conext SW name is highlighted Begin customizing the device name e To change the character press the up or down arrow button Holding down the button causes the characters to scroll more quickly e To delete the character press Exit e To add characters press Enter When the correct character is shown press Enter to select it After pressing Enter to select the last character of your customized device name press Enter again to return to the menu 4 25 Configuration via SCP Setting the Device Number Setting the device number gives a Xanbus enabled device a unique identity when several devices of the same type are installed in the networked power system When each identical device has a unique number the SCP can correctly identify and disp
91. tions AWARNING ENERGY AND FIRE HAZARD e Always wear proper non absorbent gloves complete eye protection and clothing protection e Remove all personal metal items like rings bracelets and watches when working with batteries See CAUTION below e Never smoke or allow a spark or flame near batteries Failure to follow these instructions can result in death or serious injury A CAUTION BURN HAZARD Batteries can produce a short circuit current high enough to weld a ring or metal bracelet or the like to the battery terminal causing a severe burn Failure to follow these instructions can result in moderate or minor injury A CAUTION ELECTRIC SHOCK HAZARD Determine if the battery is inadvertently earthed grounded If inadvertently grounded remove the source from ground e Avoid contact with any part of a grounded battery e Remove ground during installation and maintenance Failure to follow these instructions can result in moderate or minor injury 975 0636 01 01 Rev B vii Safety Regulatory viii A CAUTION CHEMICAL HAZARD Never allow battery acid to drip when reading specific gravity or filling battery Make sure the area around the battery is well ventilated e Make sure the voltage of the batteries matches the output voltage of the inverter charger e Study and follow all of the battery manufacturer s specific precautions such as removing or not
92. tly decreased performance See Inverter Specifications on page 6 2 for information on continuous operation at higher than rated power Difficulty on starting loads The inverter charger should be able to operate all AC loads rated at or below its power rating Some high horsepower induction motors used in pumps and other motor operated equipment require very high surge currents to start and the inverter charger may have difficulty starting these loads If you have problems starting certain loads ensure that e The battery connections are tight and clean e The DC cabling is no longer than the recommended length Refer to the Conext SW Inverter Charger Installation Guide for this information e The AC wiring is of recommended size Refer to the Conext SW Inverter Charger Installation Guide for this information e The battery is of sufficient capacity and is fully charged Battery power during AC bypass When qualified incoming AC is detected by the inverter charger and the battery is sufficiently charged the AC is automatically passed through to the loads However when there is qualified incoming AC but there is no battery power that is the battery is disconnected from the inverter charger for some reason the inverter charger will not be able to successfully pass the AC through to the loads A connected battery with sufficient power is needed for AC bypass to occur NOTICE EQUIPMENT DAMAGE Do not energize and opera
93. to change the settings Figure 4 9 Multi Unit Config Menu Screen IMPORTANT Accessing this menu automatically places the Conext SW in standby mode When entering the Multi Unit Config menu the unit identifies itself by flashing all front panel LEDs After exiting the Multi Unit Config menu the Conext SW returns to operating mode and the front panel LEDs stop flashing Table 4 12 Multi Unit Menu Description and Values Item Description Default Range Dev Name Allows the customizing CSW4024E Can be changed of the default name for will vary from by the user the inverter charger model to model This setting is optional and does not affect operation See Setting the Device Name on page 4 25 Dev Number Allows setting of a 00 usually fora 00 31 unique unit number in a multiple unit system See Setting the Device Number on page 4 26 single unit or for two units this will designate the master 1 In Conext SW Inverter Chargers multiple unit configuration installation is limited to two units one master unit and one slave unit 975 0636 01 01 RevB 4 23 Configuration via SCP AC In setting 4 24 Table 4 12 Multi Unit Menu Description and Values Item Description Default Range Invtr Mode For this to operate one Master Master Slave Conext SW must be configured to Master and the other as Slave otherwise a system wide fault is asserted AC In For identifying
94. ttery Positive DC terminal connects to the positive battery cable red 2 Battery Negative DC terminal connects to the negative battery cable black 3 XANBUS interface ports are used to connect Xanbus enabled devices including the optional SCP and AGS STACKING port Feature not available in these models a Remote REM port provides connection for the on off remote switch Battery temperature sensor BTS port provides connection for the battery temperature sensor supplied AC input output wiring compartment access panel with the compartment cover AC knockouts 975 0636 01 01 Rev B Operation The following topics will be covered in this chapter e Start Up Behavior e Conext SW Front Panel e Conext SW with the SCP System Control Panel e Battery Charging Reference 975 0636 01 01 Rev B 3 1 Operation Start Up Behavior 3 2 When the Conext SW is powered up energized or has been reset using the Reset button on the front panel all of the front panel LEDs illuminate and remain on for a minimum of five seconds During this interval the fans also turn on as the unit executes internal diagnostics The Conext SW inverter function is initially disabled meaning the unit will not invert even if there is sufficient battery voltage every time the Conext SW is energized for the first time After being energized the Inv Enable button on the front panel can be used to enable o
95. tting the Chg Block Start and Chg Block Stop to the same time disables Charger Block Disabling Charger Block means that charging is allowed to occur at any time when the right conditions for charging exist 975 0636 01 01 Rev B 4 17 Configuration via SCP Custom Battery Settings Menu NOTICE EQUIPMENT DAMAGE Consult your battery manufacturer and associated documentation before setting a custom battery type and before battery charging or equalization Failure to follow this instruction may cause damage to the battery Custom Settings appears only when Batt Type is set to Custom Eqlz Support Enabled Eqlz Voltage 32 0V Bulk Voltage 28 8V 28 8V 27 0V 54mV C CSW4024E 00 Chg Batt Type Custom Custom Settings Batt Capacity 220Ah Max Chg Rate 1007 Charge Cucle 3 Stage Eqlz Voltage appears only when Eglz Support is Enabled fibsorb Voltage Float Voltage BattTempComp Follow procedures on To select and change a configurable setting on page 4 6 to change the settings Figure 4 6 Custom Settings Menu Screen Table 4 7 Setting Defaults and Ranges Model SW 2524 230 SW 4024 230 Item Default Min Max Default Min Max Eqlz Support Enabled Enabled Enabled Enabled Disabled Disabled Eqlz Voltage 32 0V 27 0V 32 0V 32 0V 27 0V 32 0V Bulk Voltage 28 8V 24 0V 32 0V 28 8V 24 0V 32 0V Absorb Voltage 28 8V 24 0V 32 0V
96. twork 975 0636 01 01 Rev B 541 5 12 975 0636 01 01 RevB Specifications NOTE Specifications are subject to change without prior notice Specifications Inverter Specifications NOTE All inverter specifications are at nominal conditions ambient temperature of 25 C 230 VAC 50 Hz input unless otherwise specified AC Output SW 2524 230 SW 4024 230 Output waveform true sine wave true sine wave Continuous output power AC Maximum 2500 W 3500 W 30 minutes 2800 WA 4000 W Maximum continuous output current 11A 16A Surge power rating 5 seconds 5000 W 7000 We Inverter peak output current 24 3A 42A AC OUTPUT connection Single Phase L N Single Phase L N Peak efficiency 91 5 92 Output power factor O to 1 Oto 1 capacitive or inductive Operating voltage range 216 232 VAC 216 232 VAC Nominal voltage 230 VAC 230 VAC Operating frequency range selectable selectable 50 or 60 Hz 50 or 60 Hz Default output frequency 50 Hz 50 Hz DC Input SW 2524 230 SW 4024 230 Voltage range 20 34 VDC 20 34 VDC Maximum continuous power voltage 22 27 VDC 22 27 VDC range Maximum battery current 250A 250A No load power draw Inverter On 38W 40W Low battery voltage shutdown cut off 21 0 V default other values selectable 21 0 V default High battery voltage shutdown cut off 33 0 V default other values selectable a 2800 W for 30 minutes
97. ulk 12 bulk charging stage 15 C Charger Block start and stop 17 charger settings menu description 13 charging battery temperature sensor 4 built in charge formulas 4 dead battery 4 equalization 4 load management 4 custom battery menu 18 D default settings restoring 27 Down arrow button 8 E Enter button 8 equalize charging 16 equalize mode 12 Exit button 8 975 0636 01 01 Rev B F fault warning LED Xanbus System Control Panel 8 Float 13 float charging stage 16 G generator support 12 generator support menu description 22 H High surge capacity 3 Information about Your System form ii Invert 12 inverter serial number ii Inverter Block start and stop 12 inverter settings menu description 7 9 K keypress for system standby mode 9 L LdSenseActv 13 M meters screen 15 Multiple Unit Configuration 5 multi unit menu screen 23 Multi stage charging 3 N no float charging stage 16 NoFloat 13 P Power factor correction 3 Power Share 6 proof of purchase ii IX 1 Index Q qualifying AC 12 R restore default settings 27 S Schneider Electric web site iv search mode 17 9 10 11 serial number ii standby button 8 9 system home screen 10 System standby mode 9 1 Temperature controlled 3 troubleshooting general guidelines 2 motor loads 3 problem loads 3 resistive loads 3 True Sine Wave output 3 two stage charge mode 16 U Up arrow button 8 X Xanbus SCP device set
98. up menus 14 features 8 select device menu 14 Xanbus enabled 3 IX 2 975 0636 01 01 Rev B Schneider Electric www schneider electric com For other country details please contact your local Schneider Electric Sales Representative or visit the Schneider Electric website at http Awww schneider electric com sites corporate en support operations local operations local operations page 975 0636 01 01 RevB Printed in Canada
99. v Info screen appears Use the up or down arrow buttons to select which information log you want to view then press Enter to confirm a selection The log screen appears 4 Use the up or down arrow buttons to scroll the list then press Enter to view the particular log entry 5 Press the Exit button to return to previous screens 975 0636 01 01 Rev B Troubleshooting the Conext SW via the SCP Troubleshooting the Conext SW via the SCP The Conext SW is designed with a number of protection features to provide efficient operation If however you have any problems operating your inverter charger read this troubleshooting chapter If you cannot resolve the problem record the necessary information This information will help Customer Service to assist you better when you contact them A DANGER ELECTRICAL SHOCK HAZARD Do not disassemble the inverter charger The Conext SW contains no user serviceable parts Failure to follow these instructions will result in death or serious injury When a fault detection or warning message appears you can acknowledge the message to clear the screen To acknowledge a fault detection or warning message press the Enter button on the SCP This action does not clear the fault detection or warning condition so you should consult Table 5 3 for suggested actions after you have acknowledged the message Refer to the System Control Panel Owner s Guide for more information on faults and warnings
100. voltage approaches the minimum acceptable level See Multiple Unit Configuration on page 1 5 See Generator Support on page 1 5 975 0636 01 01 Rev B Key Features Multiple Unit Configuration Conext SW Inverter Charger supports multiple unit configuration to increase capacity This also requires the installer to select a Master unit and a Slave unit or units Parallel Multiple Multiple unit configuration allows two inverter chargers to operate in parallel Unit Configuration thereby doubling the capacity in inverter mode The multiple inverters communicate over the Xanbus network and intelligently share the load and balance the load between the units The Master Conext SW synchronizes operation through the Xanbus network between the other unit When AC loads are present all units produce power effectively sharing the load When Search mode is enabled only the Master unit produces the AC output Multiple Unit Multiple Conext SW Inverter Chargers synchronize charging stages to ensure Charging efficient charging of the battery bank When a single unit transitions from bulk to absorption so do all other units In absorption all units must complete the absorption stage before transitioning to the next stage Note that units do not load share when charging except during the bulk stage The Conext SWs stop sharing charge current just before completing the bulk stage The units do not share charge current during the absorption and floa
101. ys the Meters screen See To view the Meters screen on page 3 15 Basic Select to display and or adjust the basic Conext SW settings Settings See Configuring Basic Settings on page 4 7 Advanced Select to display and or adjust the advanced Conext SW Settings settings See Configuring Advanced Settings on page 4 9 NOTE Meters and View Device Info are not operational settings rather they are informational Basic and Advanced Settings are covered in another section of the guide 3 17 Operation CSW4024E 00 Setup Meters Inverter Search Mode Charger Force Chg State Bulk Equalize Clear Faults Warnings View Device Info Basic Settings Disabled f Mode Operating j H IxEnabled Disabled xEnabled Disabled IxEnabled Disabled TxBulk Float NoF loat Ieee aes xEnabled Disabled ME IxOperating Standby Figure 3 8 Conext SW Setup Menu Operational Settings To change an operational setting 1 8 4 From the device Setup menu screen use the up or down arrow buttons to highlight any operational setting you wish to change Press Enter then use the up or down arrow buttons to move between selections For example the inverter setting can be changed to either Enabled or Disabled Press Enter to confirm the selection Press Exit twice