AVX-300 English Manual - Av
Contents
1. For pole and post installations consider adding a proper adaptor not supplied Terminal Block Connections AO a O O A a AO a 2 f 2 2 s 5 ake Fig 3 Wiring connections Terminal 1 Marked GND Connect to the ground of the control panel Terminal 2 Marked 12V Connect to a positive Voltage of 8 2 16Vdc source usually from the alarm control unit Terminals 4 5 amp 6 Marked NC C NO These are the output relay contacts of the detector Connect to a normally closed or normally opened zone in the control unit When an intruder is detected alarm relay N O and N C switch for 1 8 sec Terminals 8 amp 9 Marked Tamper If a Tamper function is required connect these Terminals to a 24 hour normally closed protective zone in the control unit If the top cover of the detector is opened or the detector is detached from installation wall an immediate alarm signal will be sent to the control unit Terminals 3 7 amp 10 Marked EOL End of line optional terminals for end of line resistors connections Wire size requirements Use 22 AWG or larger wires Use the following table to determine required wire gauge and length Wire Gauge 22 20 18 16 Wire Length m 205 310 510 870 Ft 800 1200 2000 3400 For wires that placed under ground at high humidity areas and similar use NYY special wires Top PCB Layout Terminal block rae Tamper swi
2. 15m SIDE VIEW Fig 6 Wide Angel WA PIR MW Detection Pattern For LR Long Range mirror optic optional Model AVX 300 LR For long range optics order item AVX 300 LR range is about 20 meters one beam Consider that this type has higher false alarm rate Group A Positions 0 and 1 set sensitivity for 40m detection range Group B Positions 6 and 7 set sensitivity for 28m detection range Group C Positions B and C set sensitivity for 15m detection range Each range group includes 5 or 6 setting levels according to environmental condition risk Example If detector is used for 15m range with sunlight set switch to position 8 or 9 Jumpers Setting LED Mode Jumper JP2 Connect a jumper between the marked terminals to enable or disable the LED ON or OFF OFF LED OFF LED Buzzer Mode Jumper JP3 E ON OFF LED ON LED ON Buzzer provides the sound indication of Alarm signal If a buzzer function is required connect a jumper in position ON if it is not required in position OFF BUZZER OFF Buzzer OFF Hi ON BUZZER Buzzer ON ai ON The buzzer function is useful during walk test when it is hard to see the LED Important Reset the detector from Control Panel or by powering down than powering up before the new settings will take effect Test procedure Walk Test After tuning the sensitivity connect 12Vdc power to the system Allow 2 minutes of warm up time Mak
3. systems ltd AVX 300 Outdoor PIR with Double Dual Mirror INSTALLATION INSTRUCTIONS amp USER MANUAL Item 4786 A4BKE Revision II June 2012 I Av Gad Systems Ltd Panorama House 84 Ben Zvi Road Tel Aviv 68 104 Israel P O B 49 080 Tel Aviv 61 490 Israel WWW av gad com Tel 972 3 681 6767 Fax 972 3 683 5505 The AVX 300 is unique PIR and Microwave detector for outdoor IP 66 and harsh environment applications It comprises of Double Mirror Optics and advanced MW Detector inside stylist rigid plastic body This special mirror optics combined with state of the art MW Doppler sensor assures elimination of false alarms while maintaining high security standards for the detection of human intruders into protected area The detection sensitivity and range is controlled by digital rotary switch allowing 16 calibration levels so that the effective pattern will be set for every installation environment and protection site The AVX 300 is designed to protect large areas and can easily be installed on walls in order to provide a solid protection of the area while rejects interferences from birds and small animals due to Pet Mask optics The AVX 300 is designed for continuous round the clock operation and keeps its performances within a wide temperature and humidity range AVX 300 FEATURES Double Dual PYRO sensor Full pattern double mirror optics MW detection based on Doppler concept Adjusted
4. e sure that the protected area is cleared of all people 1 Start walking across the detection zone 2 Listen to ALARM sound whenever motion is detected The red LED turns on also whenever motion is detected 3 Allow 5 sec between each test for the detector to stabilize Specifications Detection Method Double Dual Element PIR amp MW Wide Range Mirror Pattern 90 5 with 30 zones detection 9 9 GHz 10 525 GHz Microwave Frequency 10 687 GHz 2 45 GHz Scope Length of protection zone Max 21m WA aon 40m LR mirror Power Supply Voltage 9 6 to 15 V filtered DC Start up 28mA 3mA Current consumption Standby 23mA 3mA Active 20mA 3mA Pp alayconiaets vale N C 28Vdc 0 1 A with 10 Ohm protection resistors y N O 28Vdc 0 1 A with 10 Ohm protection resistors Warm up Period 120 Sec Max Alarm Period 1 8 Sec Max N C 28 Vdc Maximum current 0 1 A open when cover is Tamper Switch wea Detection Speed Target velocity 0 3 to 3 0 3 to 3 m sec Dimensions of unit with bracket 192mm x 153mm x 251mm Operating temperature range 20 C 60 C All openings with gasket and sealed Protection Degree Protection against water and dust IP 66 level RFI Protection 30V m 10 1000 MHz EMI Protection 50 000V of electrical interference from lightning or power through Visible Light Protection Stable against halogen light sunlight or reflecting light www av gad com Warranty is according to Av Gad Detecto
5. emperature changes Wall angle of more than 10 from perpendicular line Mounting at more than 10 Deviation from horizontal line Facing metal doors Avoid installation of AVX 300 on the following types of ground Thick vegetation grass un mown large water sand and metal Install the AVX 300 on stable and moving free objects NOTE Recommended installation height is 2 4 meter The Double Dual high quality sensor detects motion crossing the beam it is less sensitive detecting motion towards the detector The AVX 300 performs best when provided with a constant and stable environment In order to ensure suitable operation of the AVX 300 type of ground should be one of the following Asphalt Cement Soil Clay Gravel or Grass mown Mounting the detector Holding a P screw Plastic wing nut Fig 1 Cover opening Fig 2 Wiring and positioning Use the AVX 300 integrated bracket for wall installation Remove top cover by unscrewing the holding screw at the topside of the bracket Attach bracket to the wall using 4 screws and anchors See fig 1 Insert the wire through the line hole wire bracket under silicon gasket See fig 2 Access for wiring connections is easy via the terminal block located on the PCB See fig 3 For detector alignment unscrew the plastic wing nut adjust the detector facing against the center of protected area and tighten the nut Replace the detector top cover Screw the holding screw
6. horizontally between 0 and 180 FET based DRO with strip line antenna VLSI based electronics with movement speed spectrum analysis N O amp N C relays switched at the same time Height installation calibrations free from 1 5m to 3 0m Pet and small animal Immunity up 40kg 16 levels of MW and PIR sensitivity rotary switch adjustment Environmental immunity Temperature compensation Micro controller signal processing Tamper protection Sound indication for walk test and intruder detection Unique waterproof and seal plastic design Detection Range Up to 20m Detect human intruders walking or running No maintenance required High RFI EMI Immunity Protection from Direct sunlight wind up to 30 m sec snow and rain small Pet animals removing the top cover housing pulling out or destruction Selecting mounting location The installation of the AVX 300 requires straight and solid base for the detector Local conditions of the protected zone better free from obstacles like walls fences trees ditches RF microwave The AVX 300 intergraded bracket provides installation on the wall allowing changing the installation angle vertically and horizontally in wide range Fig 2 choose a wall level with a maximum slope angle of 10 Consider a location that most likely intercept an intruder according to detection pattern in Fig 6 Avoid the following Installation Locations Facing direct sunlight Facing areas subject to rapid t
7. rs and Sensors Warranty terms and manual Specifications are subject to change without prior notice
8. tch Buzzer Serial Type lable Buzzer Switch Rotary switch Status LEDs Sealing rubber i Ga e Fig 4 Interface PCB layout LED Indicators Yellow LED MW detection is blinking during warm up period and self testing Green LED PIR detection Red LED Alarm Test and Tuning Sensitivity and Range Adjustment The calibration of range and sensitivity is performed by single digital 16 position rotary switch There are 3 groups of switch setting according to detection range Each group is divided to several levels of sensitivity according to installation environment The sensitivity levels values changed upon the mirror optic type WA wide angle LR Long range Important Make walk test at least once a week to confirm proper operation cause alarm trig and coverage of the detector Low Risk Low Risk Risk High Risk Noisy Area High Risk Very High Risk Very High Risk R High Risk Noisy Area Extremely Noisy Area High Risk Risk Low Risk Low Risk Low Risk Low Risk Risk High Risk High Risk Very High Risk Installation Hight 3m l Bracket Angle 0 Noisy Area Fig 5 Rotary switch setting For WA Wide Angle mirror optic The WA version is covering 18 meters range and 90 at temperature of 21 C As the temperature rise the sensitivity is decreasing AVX 300 Pattern TOPVIEW PIR mirror 90 5 PIR MIW Pattern
Download Pdf Manuals
Related Search
Related Contents
Converter Country Guide DO YOU NEED A VOLTAGE la version pdf 取扱説明書 Vehicle Data Recorder - Motorcraft Technical Resource 2015 Forte Owner`s Manual manuel d instructions iti bag2 mix pour family condens ED9732NV User Manual MANUAL DEL OPERADOR Posologie Chlorella - Ails des ours “nuova” forma geometrica Quando Le Corbusier pubblicò Copyright © All rights reserved.