        Digital Multimeter Model C.A 5240
         Contents
1.                             Hz 100 Hz 1 kHz 10kHz  100 kHz  2    400 kHz  Resolution 0 01 Hz 0 1 Hz 1 Hz 10 Hz 100 Hz    9 i  Accuracy   0 1  reading    10 counts   4 counts   10 counts   Permitted   overload 500 V rms and 750 V peak   Operating a  at 500 V   range  1                  1  Trigger threshold     gt  500 mV from 1 Hz to 100 kHz   gt  1 5 V from 100 kHz to 500 kHz    5   CONTINUITY AND RESISTANCE       A Never test a resistance on a live circuit  HH Plug the leads into the multimeter and connect to the terminals of  the circuit or component to be tested     E Put the switch in the ohmmeter e     Q position  Press on the Q   en   button to switch from the audible continuity  test to the measurement of resistance and vice versa     Hi Automatic measurement selection  read off the value measured  I To save the measurement  if required  press on the HOLD button     If necessary  press on the following buttons    MM RANGE to select the measurement manually  HB MIN MAX to read min  and max  values    EH   to light the display    5 1 Resistances                                     Q 400 Q 4kQ 40 ka 400 kQ 4MQ 40 MQ  Digital  resolution   0 12 12 10Q   1002   1kQ   10kQ  Bargraph   ioo   100   iko   10ka   100k   1Ma  resolution  Accuracy   0 3  rdg   0 2  rdg   3 cts  0 2 rdg    1 rdg    10 cts   6 cts  10 cts  Oleo Wen  ay  lt 25V    circuit is live  Protection 500 V rms and 750 V peak                5 2 Audible continuity test e     On the 400 Q  measurement  a continu
2.  factor FC  lt 3  full scale  and FC  lt 6  mid scale    2  Use for 40 Hz to 1000 Hz frequencies   3  Admissible overloads   12 A for 30 seconds for 10 A measurements  600 mA for 30 seconds for 400 mA measurements    9   GENERAL SPECIFICATIONS       9 1 Dimensions and weight  M25x7x1 7   64x 177 x 42 mm  M 12 3 ounces  350 g     9 2 Power supply  E One battery 9 V  EH Autonomy   200 hrs with type 6 F22 battery  400 hrs with alkaline type 6 LF 22 battery  EH Indication of battery wear   C3  HH Automatic cut out after 30 minutes  Note   Restart from the OFF position    9 3 Buzzer   EH Continuous audible beep for the continuity test   EH Intermittent audible beep each time the switch and buttons are  activated and to indicate overruns     9 4 Climatic conditions  HH Temperature   use   0  C to  50  C   storage    20  C to  60  C  EH Relative humidity   use    lt  70  RH  storage    lt  80  RH  EH Altitude   use  lt  2000 m    9 5 Conformity with international standards    9 5 1 Electrical safety  as per IEC 1010 1    M Double insulation   W Installation category   Ill   M Degree of pollution  2 MW Assigned voltage   600 V RMS  Note   This overload category III multimeter conforms to the strict  reliability and availability requirements corresponding to fixed industrial  and domestic installations  IEC 664 1                              9 5 2 Electromagnetic compatibility  conforms to CE  M Emission  EN 50081 1  W Immunity  EN 50082 1     9 5 3 Mechanical protection  EH Degree of
3.  minimum voltage of 600 V and a voltage  surge of category III    M Never open the multimeter case before disconnecting from any  electrical source    M Never connect up to a circuit to be measured if the multimeter  case is not closed correctly    Ml Before any measurements are taken  ensure the leads and switch  are in the correct positions     EH Never measure resistances on a circuit with the power switched on     CONTENTS           T    Presentation beis 3  2  Description omic iia dn 4  3  DG and AC voltage  V  riiocoroiconmairi seeren arena nes 5  4  Frequency  HZ  isse LE BES LEE 6  5  Continuity and resistance  Q eM      ccceeeeeseeeeeteeeeeeeeeeees 6  6   Diode test  Suman ita 7  7  Capacitance   4p  coonmonononcnnnnncnncnncnnnrnccn nan conca 8  8  DC and AC current  A and MA   ococonicncnnnncnnncccnnconnnnnrncancnnos 8  9  General specifications 0 2    ee eee eect eeeceeeeeeeeeeseeaeeeeeaeeeeeeeeeaes 9  10  To order  accessories and spares         eee eee eeeeeeeeeee 10  11  Warranty oo    eee 10  12  Maintenance oe 10   Technical and Sales Assistance  wl  13  AD PONIX vuccocncicic is 32    1   PRESENTATION       The C A  5240 multimeter is intended to satisfy the everyday  requirements of electricity professionals        true RMS measurement    40 000 count digital display and 40 segment bargraph    automatic or manual selection of measurement      stops automatically after 30 minutes if a command or function has  not been activated      possibility of permanent op
4.  watertightness  IEC 529    protection index IP 40    10   TO ORDER       Use designations and references below    CADA Ea ES ran ae added ege Cat  2116 77  Sold with shockproof case  a pair of leads with probes attached    a 9 V battery and this user s manual   Accessories    BAC current probe model MN 251  200 A AC              Cat  2115 77  BAC current probe model MD 303  500 A AC              Cat  1201 21  BAC current probe model SR 652  1000 A AC             Cat  2113 46    m AC DC MicroProbe model K110   from 100 yA AC DC to 300 mA AC  450 mA DC     Cat  2111 73  E AC DC current probe model MR410        400 A AC 600 A DC  coccocccncccoconicononononccnnonccnncnnanaconcnnno Cat  1200 70  mAmpFLEX model 1000 24 1 1  1000 A AC                Cat  2112 39  E Replacement leads     ooooocoonccconiccciniccnnncccnocccinnncncnnnno Cat  2118 66  W Soft Carrying Case oo  ee eeeeeeteeteeneeeeteeeeeeeeeeateeeneeees Cat  2118 65  m Replacement shockproof case    oooocccocccocacoccconinananinos Cat  2980 15    Cat  2970 28  Cat  2970 21    mFuse set of 10 0 5A  mFuse set of 10 12A       11   WARRANTY       Our guarantee is applicable for three years after the date on which  the equipment is made available  copy available on request      12   MAINTENANCE       A For maintenance  use only specified spare parts   The manufacturer will not be held responsible for any  accident occurring following a repair done other than by its  After Sales Service or approved repairers     12 1 Replacemen
5. Digital Multimeter  Model C A 5240       User manual    ENGLISH       Meaning of the symbol A   Warning   Please refer to the User s Manual before using the  instrument    In this User s Manual  the instructions preceded by the above  symbol  should they not be carried out as shown  can result in a  physical accident or damage the instrument and the installations                             Meaning of the symbol  This device is protected by a double insulation or by a reinforced  insulation  No linking is required from the protection earth terminal  to ensure the electrical security              Thank you for purchasing a C A 5240 Multimeter   To get the best service from this instrument     W read this user s manual carefully    EH respect the safety precautions detailed     A SAFETY PRECAUTIONS A       EH Ensure that the value and type of fuses are respected  otherwise  the instrument may be damaged and the warranty cancelled      0 5 A HBC fuse     rapid F  500 V min      10 kA     6 3 x 32 mm     12 A HBC fuse     gR  600 V min      300 kA     10 3 x 38 mm    M Never use on voltage to earth circuits above 600 V  with a voltage  surge category of over Ill  that is to say  fixed industrial and domestic  installations  ref  IEC 664 1     M To be used indoors in environments with a maximum pollution  degree of 2  ref  IEC 664 1   a temperature between O and 50  C  and relative humidity below 70     EH Use accessories which conform to safety standards   IEC 1010 2 031   with a
6. ent  to switch from automatic to manual  mode  Hold the button down   gt  3 secs  to switch back to automatic  mode    Note   RANGE cannot be activated in Hz  automatic selection only     RANGE   Auto        Manual  4  gt 3s    Q     en                                                              HH Permanent operation  possibility of inhibiting automatic cut out   by keeping this button pressed before activating the switch from  the OFF position    Return to the OFF position cancels out permanent operation mode   the instrument automatically cuts out after 30 minutes if no  command or function is activated        mis  se         To switch the display lighting on and off   Note   switches off automatically after 1 minute                FUNCTION SWITCH    OFF  The off position   V  Alternating voltage up to 600 V   V   Direct and alternating voltage up to 600 V  Hz   Voltage frequency  up to 500 kHz    e     Q   Audible continuity test for R  lt  40 Q  resistance and resistance  measurements up to 40 MQ          Diode test  Junction voltage  RANGE is displayed                                              d    Capacities up to 40 uF  mA   Current up to 400 mA   and    on   terminal   10 A  10A   and   current  on 10 A terminal   RANGE is displayed                             O  Y 4 mm SAFETY TERMINALS    E COM   common  terminal for black lead  EH     terminal for red lead  E 10A  terminal for red lead 10 A   and   measurements    3 DC AND AC VOLTAGE       KM Plug the leads int
7. eration  see RANGE      Various measurement accessories broaden the scope of application  or provide the multimeter with new functions     See the list of accessories and references on the     To Order     page   Documentation upon request      Note   Always use accessories suitable for the voltage and the voltage  surge category of the circuit to be measured  as per IEC 1010      2   DESCRIPTION        See drawing in 13   APPENDIX      D LIQUID CRYSTAL DISPLAY    E 40 000 count measurement  height of figures  10 mm   Rate   2 measurements per second  E 40 segment bargraph  Rate   20 measurements per second  Note   the bargraph is inhibited in V       Hz and 4p  HB Automatic display of all command  measurement and function  symbols  W Battery level indicator    W Overrun indicator      the 4th from the left flashes    arrow at the far end of the bargraph    O CONTROL BUTTONS                                   and Q  em   In mA and 10A  to switch from direct     to alternating     and  vice versa Am     A   hy  E In Va  to switch from V   to V       and vice versa  Va     Via    ha 1             EH In Q  to switch from Q to e     and vice versa    HOLD  EH To hold the display of the last measurement  HOLD is displayed     MIN   MAX   PEAK   EH To display minimum and maximum values one after the other   The instrument goes into manual measurement selection    HB Hold this button down to switch to PEAK mode  1 ms   Only active   in V   mA and A      RANGE  I Selection of measurem
8. o the multimeter and connect up in parallel to the  circuit to be tested    EH Put the switch in the voltmeter V  or V    position   HH Automatic measurement selection  read off the value measured   EH Save the value  if necessary  by pressing on the HOLD button    If necessary  press on the following buttons    HE RANGE to select the measurement manually   HE MIN MAX to read off minimum  maximum or PEAK values    EH  gt   To light up the display                                            V   and     400 mV 4V 40 V 400 V 600 V  2   dE tonv   toonv   tmv   10mv   100mV  Eat al 1 mv 1omv   100mv   1v 10 V  Impedance 3 MQ 2 3 MQ  me e F 9 BUSSE    0 1  rdg   3 count  ae ey HEM esis   1 5  rdg   20 counts  Aopuracy  2  OS   2   reading   20 counts  KR 600 V eff  and 900 V peak                 1  Peak factor Fe  lt 3  full scale   Peak factor Fc  lt 6  mid scale    40 Hz frequency at 1 kHz  except for400 mV   measurement from 40 to 60 Hz  Rejection ratio   in common mode up to 1000 V    gt  110 dB and in series mode  gt  55 dB  50 and 60 Hz       2  Not accessible    4   FREQUENCY       HM Plug the leads into the multimeter and connect in parallel to the  circuit to be tested    HB Put the switch in the Hz voltage frequency position   HB Automatic measurement selection  read off the value measured  Note   the bargraph is inhibited when measuring frequency   EH If necessary  press on the following buttons      MIN MAX to read min  and max  values    3  to light up the display      
9. ous beep is emitted for a  resistance R  lt  40 Q  Response time   100 m  secs    Protection   same as resistances    6   DIODE TEST       A Never test a diode on a live circuit     EH Plug the leads into the multimeter and connect to the terminals of  the component to be tested     EH Put the switch in the     function       in the direct direction  the display gives the value of the junction  in volts  1 mV resolution      accuracy   1 L 10ct     live circuit voltage    lt  3V      short circuit current   0 8 mA     in the reverse direction  the display indicates the voltage of the  live circuit  in the region of 4 V     EH Save the value  if necessary by pressing on the HOLD button    KM With this function  apart from testing classic diodes  it is also  possible to test electroluminescent diodes  LED s or any other  semi conductor whose junction corresponds to a direct voltage of  less than 3 V      EH Protection   same as resistances    7   CAPACITANCE       A Never measure capacity on a live circuit   Always respect the polarity of the electrolytic condensers   This type of condenser may be temperature sensitive   do not touch it  therefore  during measurement   I Plug the leads into the multimeter and connect to the condenser  terminals     WM Put the switch in the capacitance meter position 4     KM Automatic measurement selection  read off the value measured  Note   The bargraph is inhibited during capacitance measurement    E To save the measurement  if required  pre
10. ss on the HOLD button     If necessary  press on the following buttons    RANGE to select the measurement manually  E MIN MAX to read min  and max  values   W  gt  lt  to light the display                                     JE 4nF 40nF 400nF 4 uF 40 pF  1   Resolution 1 pF 10 pF 100 pF 1 nF 10 nF   2 R  Accuracy  3   rdg   20 ct   1 5  rdg   5 cts  5ct  Protection 500 V rms and 750 V peak        1  For a capacitance C  gt  20 uF  the accuracy is   3 5  rdg   10 counts    8 DC AND AC CURRENT       A Always disconnect the circuit to be tested before connecting  the multimeter to the circuit   I Be careful   plug the leads into the multimeter and connect in series  to the circuit      the red lead on the         Terminal  up to 400 mA    the red lead on the    10 A    terminal  from 400 mA to 10 A  HB Put the switch in the ammeter A or mA position  Press on the     button to select d c  or a c     WB Reconnect the circuit to be tested to the power  E Automatic measurement selection   read off the value measured    E If necessary  press on the following buttons      RANGE to select the measurement manually    MIN MAX to read min  and max  values       to light the display                            A   and   40 mA 400 mA 10A  ahs AS 200 mV 1v 400 mV  uo 1 HA 10 HA 1 mA  Sr Hal 0 1 mA 1 mA 100mA  De   0 5  rdg   5 counts eee  li AG a   0 9  rdg   10 counts DENE  Protection  3  Fuse 0 5 A HBC Fuse 12 AHBC                    1  Voltage drop at terminals for 40 mA  400 mA  10A  Peak
11. t of battery and fuses   A The multimeter must be disconnected from any electrical  source    M Put the switch in the OFF position   EH Unscrew the captive screws and remove the lower half of the casing   M Replace the worn battery with a 9 V battery  6F22 or 6LF22     EH Replace the faulty fuses  ensuring value and type are respected      0 5 A HBC rapid F fuse  600 V     10 kA     min 6 3 x 32 mm     12 A HBC gR fuse  600 V min      300 kA     10 3 x 38 mm     12 2 Storage  If the multimeter is not to be used for a period of 60 days or more   remove the battery and store separately     12 3 Cleaning    A The multimeter must be disconnected from any electrical  source    To clean the case  use a cloth dampened with soapy water  Rinse   with a damp cloth  Then dry quickly with a cloth or pulsated air     12 4 Repair and calibration   To guarantee that your instrument complies with the factory  specifications  we recommend that the Model C A 5240 be submitted  to our factory service center at one year intervals for recalibration  or  as required by other standards     For instrument repair and or calibration  please call our factory  toll   free  at  800  945 AEMC  800 945 2362       CHAUVIN ARNOUX  Inc    d b a  AEMC  Instruments   15 Faraday Drive   Dover  NH 03820 USA   Tel   800  954 2362   603  749 6434   Fax    603  742 2346     Or contact your authorised distributor    Estimates for repairs  normal recalibration  and and calibration  traceable to N I S T  are available 
12. upon request  Overseas customers  must receive written authorisation before returning any instrument     12 5 Technical and Sales Assistance   If you are experiencing any technical problems  or require any  assistance with the proper use or application of this instrument  please  call our technical hotline      CHAUVIN ARNOUX  Inc    d b a  AEMC  Instruments   99 Chauncy St    Boston  MA 02111 USA   Tel   800  343 1391   617  451 0227   Fax    617  423 2952    www aemc com    
    