1. START DAY 02 To adjust the START and STOP dates use A or v then press Set to confirm and proceed to the next screen START MONTH J UN Input Output Port Feature The RadioNet OC1 has 4 x RJ45 connections and 1 x 3 5mm Stereo Jack Socket The I O Ports are wired to connectors labelled 1 and 2 RJ45 and 3 3 5mm Jack ONLY do not use connectors labelled 4 and 5 these are reserved for future RadioNet Controller features The 3 5mm Stereo Jack Socket is a no volt short circuit input that should be activated by a switch or relay The wiring of the Stereo Jack connector is shown in the figure below To activate this port use Input Port 1 in the RadioNet software Not Used OO Wire 1 ee LS c O _ u Wire 2 The RJ45 connectors are wired in parallel either or both connectors can be used with each pair of the wires in the 8 core cable shown in the figure below 1 amp 2 Auxiliary Output White Green 12V Green Ground 3 amp 4 Input 3 5 24V AC DC White Orange Blue 5 amp 6 Input 4 5 24V AC DC White Blue Orange 7 amp 8 Input 2 Short Circuit White Brown Brown RadioNet Input Output Software Setup To setup the inputs in the software enter the menu and select Settings then Input Output Control Select the input to be used then change the settings as per below EDU PUAT For each port you need to program Maru e Select ON or Off Ar zu Bee Select Mode of ope
2. 7 6 In System Setup you can choose to turn on the pH Control feature If you have chosen to turn this feature off you must manually maintain your pH level Setting up pH control pH control menu ENTER pH VALUE is used following a water chemistry test by you or your pool professional The value entered may trigger a catch up dose of acid pH DOSING TRIM is used to make adjustments to the amount of acid dosed to achieve optimal pH balance MANUAL ACID DOSE is used to trigger an immediate measured dose of acid to the pool ENTER pH VALUE pH DOSING TRIM MANUAL ACID DOSE To change the pH value press A or v then press Set pH DOSING TRI M 410 To change the pH dosing trim decrease pH press A then press set pH DOSING TRIM mE 10 To change the pH dosing trim increase pH press v then press set MANUAL ACID DOSE screen To change the acid dose value press A or v then press Start The MINERAL TEST or Salt Test feature instructs the RadioNet to perform an approximate measurement of the Mineral concentration in the pool water It is recommended that the actual Mineral concentration be measured regularly by your pool professional The Mineral Test is also performed automatically by the RadioNet controller on a daily basis Please refer to Managing Water Quality page 31 for further details regarding Mineral Concentration TESTI NG MI NERALS I 7 7 7 d d A progress bar
3. RadioNet Outdoor Computer s default setting operates Program 1 in the morning for Control and Restore Defaults 4 hours and Program 2 in the evening for 4 hours To set a program press the enter button on the program selection screen PROGRAM 1 ON PROGRAM 2 ON PROGRAM TI MES PROGRAM 3 OFF WI NTER MODE To select a setting press A or Y then press SYSTEM SETUP enter PROGRAM 1 E h STATUS ON or each program you need to set SU Seel Select ON or OFF Select SANITISER Output 0 up to 100 I NPUT OUTPUT CONTROL RESTORE DEFAULTS PROGRAM 1 5TART 06 00am ABIRE Select START and FINISH Time Arrow up or down to adjust Time or Days PROGRAM 1 DAYS MTWTFSS Select DAYS of the Week the program will PUMP SPEED LOW operate Select PUMP SPEED if using the i Gemini Twin pump AUXILIARY STATUS ON Select AUXILIARY to control the Auxiliary DAYS MTWIF99 power supply if using the Gemini Twin Pump Select ON or Off AUXILIARY Select DAYS of the week it will operate START 06 00PM Select START and FINISH time FINISH Please note when running two programs simultaneously the Program with the higher sanitation output and pump speed will override the program with lower settings System Setup Feature System Setup Feature By Default when you first turn on your RadioNet Outdoor Computer you will be prompted with the SYSTEM SETUP screen SI SLENSSETUR POOL INTERI OR FIBREGLASS S
4. press A or y then press set to confirm and proceed to the next screen To turn the NEVA RUN DRY pump protection feature on or off press A or v then press set to proceed to the next screen To adjust the current TIME press A or Y then press set to confirm and proceed to the next screen To adjust the DAY MONTH and YEAR press A or then press set to confirm and proceed to the next screen System setup is complete NB Single soeed pumps must be plugged into the auxiliary power supply located on the back of the RadioNet Outdoor Computer Activating Deactivating Winter Mode The RadioNet Outdoor Computer will start up with Winter Mode activated To Activate or Deactivate Winter Mode From the home screen press menu and scroll down to SETTINGS and push enter Then scroll down to WINTER MODE and push enter When Status is flashing push edit Use the up or down arrows to turn on or off The Winter Mode feature instructs the RadioNet to automatically reduce the sanitiser output of the Automatic programs during winter The Winter Mode feature has three settings E The sanitiser output reduction 0 10 20 30 40 50 or 60 E The start date month and day E The stop date month and day WINTER MODE To adjust the SANITISER REDUCTION amount S e ON ress or then press Set to confirm and REDUCTION 030 a o 7 j proceed to the next screen WI NTER MODE
5. Model RN Easy to use with advanced features Looe ERS A RadioNet Outdoor Computer Display Screen 5 Features 6 Typical System Installation 8 Installing the Acid Feeding System 9 Operating the RadioNet 10 Main menu 11 Changing pH Control 12 m4 Mineral Test 13 Super Sanitise Feature 13 Backwash Mode Feature 14 Settings screen 16 l Changing Program Times 17 Co 19 at ulatio NS on ya LS ecisionto purchase a RadioNet M Outdoor System Setup Feature 18 Computer Leonardo Cel Winter Mode Feature 21 Input Port Feature 22 On screen Messages 25 Restore Defaults 26 The Poolrite RadioNet Outdoor Computer contains many advanced features that are easy System History Feature 26 to set up and control Factory pre set modes enable first time users to have an effective sanitation system and pH control from the outset As competence in operating the system Changing from Salt to MagnaPool 26 is acquired the numerous outstanding features of the RadioNet Outdoor Computer can be f an a pen Leonardo Cell 27 gt i i Dee O A ll seal eevee Managing water quality n consumption This cell is optimised for low flow energy saving pumps Customer Care amp Checklist 37 41 45 RadioNet Outdoor Computer Display Screen Should you not find what you are looking for in this Owner Handbook please E email info poolrite com and we can point you in the right direction MASHAPLUL Poolrite
6. O TEMES Ed UE POO Pass ER ORs FIBREGLASS SS CE MES E UR POOL VOLUME 50 000L SYSTEM SETUP SURFACE AREA 50m2 SYS TEMESETUR AOL ele MAGNAPOOL To clear your current SYSTEM SETUP enter the menu select settings and scroll down to the Restore Defaults option and press Enter This will bring you back to the System Setup screen To modify your current system setup enter the menu select Settings and scroll down to SYSTEM SETUP Please note Automatic and Manual modes will not operate until you have configured the SYSTEM SETUP To adjust the type of POOL INTERIOR press A or v then press Set to confirm and proceed to the next screen To adjust the POOL VOLUME press A or v then press Set to confirm and proceed to the next screen POOL VOLUME Lx W x Avg Depth To adjust the POOL SURFACE area press A or v then press Set to confirm and proceed to the next screen POOL SURFACE AREA Lx W To adjust the POOL TYPE press A or v then press Set to confirm and proceed to the next screen Select MagnaPool ONLY if using genuine MagnaPool minerals in the pool SNS DENE SE pul pH CONTROL To turn pH CONTROL on or off press A or Y then press Set to confirm and proceed to the next screen SO SENS ETUR TARGET pH To adjust the TARGET pH setting press A Or v then press Set to confirm and proceed to the next screen eile Sle REPEAT PUMP SETUP To REPEAT PUMP SETUP press A or the
7. O may display next to the output bar graph We Cam el PUMP SPEED LOW R Gemini Pump speed has been overridden by a hand held Remote An Input Port is currently active Ball 7r rro OUTPUT R T High temperature has been detected P Gemini Pump is currently priming before changing to low speed M Multiple programs are currently active W Winter mode is currently active To reset your RadioNet Outdoor Computer to the factory default settings simply select the MENU option and scroll to find SETTINGS then scroll down to RESTORE DEFAULTS This allows you to set up all settings again NB Restoring defaults allows you to change from salt to MagnaPool and vice versa RESTORE DEFAULTS Restores defaults all settings will be lost press ALL SETTINGS WILL BE next to continue with the restore or press SC OS ie IES to cancel The next screen prompts for system esc next setup refer to p16 The System History feature enables a full report of all the controller s stats E e rM 01000 Displays cell run time hours total output LEONARDO CELL ACID DOSED KA hrs and acid dosed amount L press next esc to proceed to next display screen LOW MINERALS ai DRY events and No Flow hours press next to TET proceed to next display screen Displays low minerals hours Neva Run Dry OVER CURRENT Displays Over Current events High HIGH TEMP Temperature events and over temperature OVER TEMP prev re
8. adings press Next to proceed to next display screen RF COMMS 000 RESTARTS 100 VERSI ON i em O and software version number press eSC to exit prev esc the system history Displays RF Comms events Restarts events AI A D This function will enable changing from Salt to MagnaPool or from MagnaPool to Salt From the home screen press menu and scroll down to SETTINGS and push enter Scroll down to SYSTEM SETUP and push enter To scroll through all the set up options press set until the option POOL TYPE is shown On this screen push the up or down arrow to change from Salt to MagnaPool or vice versa Please note all system set up options will be retained unless changed Leonardo Cell Before calling your Poolrite Professional carefully read the instructions contained in this User Manual Note Failure to observe the following responsibilities may result in a service fee being charged Cell Installation Installation includes the following steps 1 Mounting the controller to the wall 2 Mounting the Leonardo cell to the pipe work and 3 Assembly of the acid lines CHECKLIST L Controller is attached to the wall using the included wall mounting bracket and screws The cell is then installed in such a way so that the indicator arrows embossed on the housing are pointing towards water flow The Leonardo cell can be installed either horizontally or vertically In the case
9. ccordance with Poolrite instructions without alterations or modifications of any nature whatsoever e The Poolrite RadioNet Outdoor Computer and Leonardo Cell returned at the purchaser s expense to Poolrite or the authorised Poolrite Professional from which it was originally purchased Poolrite does not accept responsibility for goods while in transit Exclusions This warranty excludes e Faults confirmed after examination to be caused by reasonable wear and tear e Faults confirmed after examination to be caused by any of the following Incorrect Water Chemistry The System has been operated subsequent to detection of a fault The use of Non Genuine Spare Parts e Faults arising from abnormal use lack of care extreme exposure to the elements or harmful substances insect vermin infestation negligence and or Acts of God or any other factors beyond the control of Poolrite This Poolrite Warranty supersedes all other warranties whether expressed or implied Leonardo Cell 3 Year Fixed Price Servicing Explained Part of Poolrite s Leonardo Cell warranty includes fixed price servicing which is a plan for yearly preventative servicing capped at 80 plus GST 88 00 incl GST per annum The Planned Maintenance includes the following 1 8 9 Visually check cell for wear damage and signs of use in pool water with metal based algaecides present Blue or Green discolouration of cell plates Record Service Hist
10. cessible No program times will run in this mode Automatic Mode In Automatic mode the RadioNet will operate at the programmed time settings All of the menus and controls are available in this mode Manual Mode In Manual Mode the RadioNet operates immediately Programmed times are ignored and the unit will operate until the user selects System Off or Automatic Mode All of the menus and controls are available in this mode SI SUBEMNOE MAGNAPOOL To access the menu features simply press menu button from the home screen or any screen where the menu option appears in the bottom left corner of the display Please note all features programmed under the main menu work in both Automatic and Manual modes E To access the menu features simply press menu E Pressing 4 or CO will cycle through the available menu features Pressing enter will enter the menu feature displayed E To exit the menu repeatedly press esc until the main screen re appears or wait and it will reset automatically Main Menu Features PH CONTROL MI NERAL TEST SUPER SANITISE To select a feature press A or v then press enter BACKWASH Ste Wes Soe SOS AUXILIARY SOCKET Changing pH Control Mineral Test Your RadioNet Outdoor Computer s default pH level is set to 7 4 This is the optimal level for bather comfort and sanitation effectiveness Poolrite recommends keeping the pH level between 7 2
11. ch can indicate a damaged pump shaft seal this must be repaired immediately by your Poolrite Professional or further damage may occur Pump motor seems noisy Internal components may be damaged check e with your Poolrite Professional to have the pump motor serviced The pump motor does not run Power may not be getting to the motor or motor internal components may be damaged check e the mains power point by plugging in a known working appliance to ensure power is available e fuses and main power supply switch for serviceability e whether the motor has overload tripped Poolrite motors incorporate an internal thermal overload switch that will reset automatically after the motor has cooled down e for blockages in the pump lint pot preventing the motor from rotating e for a burning smell that might indicate the motor has fused or burnt out consult your Poolrite Professional as replacement may be required gt n aa lt r lt r Warranty Product Details The RadioNet Outdoor Computer and Leonardo Cell are manufactured to the highest possible standards using the most current technology In the unlikely event that a problem occurs resulting from faulty manufacture or materials this product is covered under warranty Important Information In the event of a product fault that is covered under the Warranty Terms and Conditions the purchaser must in the first instance c
12. ed 80 120 ppm Fibreglass 80 120 ppm If Total Alkalinity is too high add acid If Total Alkalinity is too low add pH buffer STEP 4 CALCIUM HARDNESS Calcium Hardness is a measure of the calcium compounds dissolved in the water Calcium Hardness levels should be as low as practical to minimise the build up of calcium deposits on the Leonardo cell and pool surfaces The recommended Calcium Hardness range is Concrete 100 200 ppm Vinyl lined 0 150 ppm Fibreglass 0 150 ppm If Calcium Hardness is too high dilution with water is required If Calcium Hardness is too low add a calcium increasing agent NOTE It is important that a Total Hardness Test is not used to measure the calcium jm hardness of a pool Only a Poolrite Professional can perform a Calcium Hardness Test STEP5 MINERAL CONCENTRATION If the RadioNet M Controller has been setup as a MagnaPool then Mineral concentration should be maintained between 3 000 ppm to 4 000 ppm TDS The Radionet Outdoor Computer will display Possible Low Minerals when the minerals are low however it is recommended that this be regularly tested by your MagnaPool Professional Alternatively if RadioNet Controller is configured for salt then concentration should be between 4 500ppm to 6 000ppm TDS If the mineral or salt level is low add MagnaPool minerals or salt see Adding Extra Minerals If the mineral or salt level is too high leave as is until the pool water is progressiv
13. ely diluted by rain or dilute with fresh water The recommended water temperature range for residential pools is between 5 C and 32 C If your RadioNet displays Check Mineral Level take a water sample to your Poolrite Professional who can advise you of the number of bags of MagnaPool minerals required If you are operating a salt system take a water sample to your Pool Professional who will also advise the amount of salt required The RadioNet Outdoor Computer is suitable for off peak installation The dosage rate for start up of a MagnaPool is 40kg per 10 000L this dosage rate is designed to produce a concentration of approximately 3 000 parts per million of minerals in the main body of pool water The table below can be used to determine the amount of 10 kg bags of minerals for start up of a given pool volume No of 10kg bags of Pool Volume L MagnaPoolMinerals No of 10kg bags of Salt Start up dosage of MagnaPool Minerals and salt in 10kg bags Before operating the RadioNet the minerals must be fully dissolved in the pool water This is best achieved by circulating the water with the RadioNet turned off for 24 hours Cloudiness and some foaming may be observed in the water until the minerals are fully dissolved To assist with dissolving regularly brush the floor of the pool with a pool broom Please refer to the manufacturer s instructions on when Minerals Salt can be added WARNING Builders that i
14. equipment is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the system safely If any power supply cord is damaged it must be replaced by a Service Technician in order to avoid a safety hazard manual automatic or Press to select menu system off mode options Press arrow to Press arrow to change values change values Features e For use on any pool system and the intuitive software design is suitable for beginners through to advanced users e Software is optimised for MagnaPool and compatible with salt systems e pH Control reliable and probeless via predictive dosing as standard e Mated with the high water velocity Leonardo Cell e Improved pool water chemistry balance and control helps save money on chemicals and increases sanitation effectiveness e Six 6 programmable run times for full pool control Control by days e Programmable sanitation output to suit pool requirements and weather conditions e Soft start programming ramps up cell output for longer cell life e Auxiliary 240V 50Hz power supply When Paired with Gemini Twin pump The RadioNet Outdoor Computer is enabled to remotely control the Gemini Twin pump The advantage of this combination is that the Auxiliary Power Supply can then be used to control other accessories such as lights heater pumps or water features The auxiliary
15. gged into a 10 amp 220 240 volt power point Remember the filter pump power lead does not need to be plugged into the power pack if using the Gemini Twin pump If using any other pump the power lead must be plugged into this Power Pack Start by selecting a suitable place to attach the Mounting Bracket using the two screws provided The Mounting Bracket must be fixed with the screws horizontal and the vent louvres facing upwards If no suitable wall is available then install a 100mm x 100mm hardwood post with a vertical weather proof mounting board 400mm wide x 300mm high x 18mm thick attached Hook the Power Pack onto the Mounting Bracket by the top edge at the rear of the box When secure plug the power lead into a suitable 220 240 volt power point but do not switch the RadioNet Power on on AR 2 The Acid Feeding unit consists of hig all Du e Acid bottle lid EIN TN e 3m of PVC tube for acid i Ji B e Non return valve nm un A e Tapping band with acid injection nozzle for eg AAA O D 50mm pipe our yy A IN To successfully install the pH Control Acid Feeding System for your RadioNet Outdoor Computer ensure all equipment is turned off 1 Remove the supplied cap on the 5L Acid Bottle and replace it with the Acid Bottle Lid su
16. he mains power point is switched on e whether the mains power point is working by plugging in a known working appliance to ensure power is available Filter pressure builds up rapidly There may be a restriction or blockage in the system check e the return water inlets for obstructions e the Leonardo cell for obstructions e that vacuum cleaning has not been attempted with the filter valve in BACKWASH position Air bubbles going back to the pool There may be a leak in the suction line check e that return water inlets have good pressure e that pipe connectors are tight e the pump lid seal is clean lubricated with silicone grease and correctly fitted and tightened The pump runs but loses suction power and there is little or no water flow There may be a leak or obstruction in the system check e that strainer baskets in pump and skimmer box are not blocked with debris NOTE after opening the pump strainer pot lid air will have entered the filtration system Re priming the pump may be necessary when the system is started again e check filter condition via pressure gauge and backwash if pressure is too high e that the pump is primed If necessary re prime as per instructions e for air bubbles under the lid tighten lid if necessary e that all pipe connectors are tight e that valves before and after the pump are fully open Pump is leaking Internal components may be damaged check e for water on the ground under the pump whi
17. he valve on the top of your filter to RINSE TI MER BACKWASH Backwash then press next RRES dns i TH TURN PUMP OFF The Rinse will run for 60 seconds or alternatively press next to turn pump off SET VALVE TO FIORE R PRESS next TO TURN PUMP ON Press next to turn pump on Set the valve to Filter then press next BACKWASH TI MER 60 The backwash will run for 60 seconds or BACKWASH PRESS next IF THE alternatively if the sight glass on the valve COMPLETE The backwash is complete SUG bas der Bee becomes clear then press next to stop the amp next pump REPEAT BACKWASH REPEAT BACKWASH Select yes if the sight glass was not clear at the end of the 60 second backwash or no to proceed to next step Ensure filter pressure gauge has returned to normal pressure If not repeat process If the pressure remains high talk to your local Poolrite Professional Settings Screen Changing Program Times To access the programs select the Menu scroll down and select settings then the program times The Program Times feature controls what times and days of the week To get to the Settings Screen from the home screen press the menu button and scroll down your RadioNet will operate automatically to the Settings option and select There are six individual programs available which allow the user to set the times of automatic operation Settings allows you to change all Programs Winter Mode System Setup Input Output The
18. n press Set to confirm and proceed to the next screen PUMP SETUP GEMINI PUMP EXTERN To ADJUST PUMP SETUP press A or Y then POWER SOCKET press Set to confirm and proceed to the next screen If using a Gemini Twin Pump it is recommended to plug it into a separate 240v power supply and select EXTERN POWER SOCKET If no sockets are available the Gemini Twin Pump can be connected via the 240v Auxiliary socket and select INTERN POWER SOCKET A standard single speed pump can also be used and must always be installed via the 240v auxiliary socket STANDARD PUMP SINGLE SPEED How to pair the Gemini Twin pump for wireless control PUMP PAI RI NG To pair a Gemini Twin pump with RadioNet HOLD DOWN MODE ON controller hold down mode on pump for 5 PUMP FOR 5 SECONDS seconds prev PUMP PAI RING GEMINI PUMP DETECTED will be GEMINI PUMP DETECTED displayed on the screen when the controller has detected the pump then press next to confirm and proceed to the next screen DIE next System Setup Feature Winter Mode Feature PUMP PAI RING PAI RI NG PUMP PAI RING PAR es UC CESS EU SCS MEMES ET UP AUDI BLE ALARM SU STEMSSETUP NEVA RUN DRY So E MSS EL TI ME 10 30AM SCS MEMES EU DATE 01 JAN 2012 SUN MENS TUE COMPLETE Pump and controller are pairing Pairing of pump and controller has been successful Press next to proceed with the next screen To turn the AUDIBLE ALARM on or off
19. nstall quartzite wall surfaces are advised to disable the Never Run Dry feature of the RadioNet as part of the start up routine then enable the Never Run Dry feature after six weeks The Mineral Test function can be used to help this process The table below can be used to determine the amount of 10kg bags of minerals for on going maintenance to 3 000 parts per million of a given pool volume Current Mineral Level ppm Current Salt Level ppm The Mineral Test function can be used to help this process The table below can be used to determine the amount of 10kg bags of minerals for on going maintenance to 3 000 parts per million of a given pool volume Pool Volume L 5 000 10 000 15 000 20 000 30 000 40 000 50 000 60 000 70 000 80 000 90 000 100 000 110 000 120 000 Pool Volume L 5 000 10 000 15 000 20 000 30 000 40 000 50 000 2 500 3 000 4 000 5 000 5 500 60 000 70 000 80 000 90 000 100 000 110 000 120 000 2 900 3 000 01010 5 000 5 500 Customer Care amp Checklist Checklist Before calling your Poolrite Professional carefully read the instructions contained in this Handbook de NOTE It is important that a Total Hardness Test is not used to measure the calcium sh hardness of a pool Only a Poolrite Professional can perform a Calcium Hardness Test Radionet Outdoor Computer and Leonardo Cell L Check correct operation of power point by connecting another known
20. of a vertical installation please make sure that the electrodes plates of the cell are on top Ifthe Leonardo cell is installed below the water level of the pool The Babych valve assembly must be replaced with the blank plug Acid lines assembly includes the steps of gluing the T piece allows acid to mix with the pool water after Leonardo cell Also be sure to fit isolating valves for servicing cell and equipment L Non return valve has to be installed on the acid tube between the T piece and the pump as close as practical to the acid pump L The acid bottle lid from a standard 5L acid bottle is recommended to be replaced with the provided lid L Every tube connection with acid pump non return valve T piece and the acid bottle has to be fitted with a supplied clip MagnaPool Water Quality All Ecosystem enabled products are optimised for MagnaPool and compatible with salt pools Here are some tips on maintaining healthy pool water Pool water needs to be balanced to maintain its quality so that swimming is healthy pleasant and enjoyable To maintain water quality some key elements need to be monitored Simple measurements can be done using the 2 in 1 Test Kit supplied by your builder or a water sample can be taken to your local Poolrite Professional for a more detailed analysis and expert advice on the correct treatment to keep your mineral water balanced The following step by step guide will assist
21. ontact the nearest authorised Poolrite Professional for assistance or Poolrite on 1300 855 894 or visit www poolrite com Terms and Conditions Should examination by Poolrite confirm to its satisfaction that the RadioNet Outdoor Computer or Leonardo Cell has failed due to faulty manufacture or materials Poolrite warrants the original purchaser of the system and specified components for the following periods from the date of original purchase RadioNet POWER PACK 1 YEAR Leonardo Cell 2 YEARS plus 3 Year fixed price servicing This Warranty is applicable to workmanship and or materials Poolrite or an authorised Poolrite Professional will repair or replace at no charge all parts returned freight paid which display faulty workmanship and or materials Poolrite does not accept responsibility for loss damage or injury to persons or property arising from warranty related failure of equipment or installation of that equipment Unless with the express prior written approval of Poolrite any repair or replacement shall be provided only by Poolrite or its authorised Poolrite Professionals and this Warranty shall not extend to any expenditure otherwise incurred by the original purchaser Limitations This Warranty extends only to e The Poolrite RadioNet Outdoor Computer and Leonardo Cell operated and maintained strictly in accordance with Poolrite instructions and installed by agents duly authorised by Poolrite strictly in a
22. ory Acid clean with a 8 1 water acid solution Degrease cell with warm water and detergent solution Check O rings and gaskets Visually check Cell Housing Remove clean and check Babych Valve Remove clean and check Water Probe Check brass terminal nuts for corrosion and tightness 10 Check cell power lead for wear and damage 11 Reassemble and check operation 12 Complete 10 Point Service Checklist and Report This service is only available as workshop service only not in field Where the unit must be returned to the nearest Poolrite Branch or service Centre the price excludes freight All parts and labour required for the fixed price service are included in the AUD 80 plus GST AUD 88 00 incl GST per year Service Charge Head Office Poolrite
23. power supply can then be operated remotely with the Gemini Twin pump remote control a pH control Power out pump Power in AUX power Comm ports for command supply signals to Pool covers spas etc Typical System Installation pH Control Installing the Acid Feeding Typical Installation 4 dl 1 RadioNet OC1 Controller 4 Backwash Tank Diagram is illustrative only please refer to 2 Leonardo Cell 5 Gemini Twin Pump your Poolrite Professional if you are unsure 3 Titan VMF Filter 6 Hummerbird Heater of the correct system position or set up The equipment must be installed more than 3 5m away from the pool to avoid splash back The Leonardo cell should be installed in a position within 1 2 metres of a vertical wall or fence to allow the RadioNet to be easily mounted without the need to provide an additional post The cell may be installed vertically or horizontally level within 5 degrees in the return pool line Ensure that the pool water flows in the direction of the arrow indicated on the body of the Leonardo Cell Heaters and other equipment in the return to pool line must be before the cell i e between the cell and filter The pH Dosing System must be installed after the cell i e between the cell and the pool The RadioNet Power Pack must be mounted on a vertical wall or fence within 1 2 metres of the cell and at least 1 metre above the ground Also it must be in a position to allow its supply lead to be plu
24. pplied with the RadioNet Outdoor Computer 2 Cut the required length of PVC tube to connect to the IN port on the Acid Pump located on the back of the RadioNet Outdoor Computer 3 Cut a second length of PVC tube to connect the OUT port on the Acid Pump to the Tapping Band This tube will connect to the Tapping Band 4 Approx 10cm from the end of the PVC tube from the OUT port which will connect to the Tapping Band cut the PVC tube and insert the Non return Valve the arrow must point to the the tapping band ensuring the 10cm cut tube is reconnected after the Non return Valve 5 Select the position for the Tapping Band on a straight section of pipe must be after the Leonardo Cell on the return line to the pool 6 Cut out a section of pipe 40mm in length 7 Fit the Tapping Band to the return line of the swimming pool and adhere with an ABS compatible gluing agent NB PVC gluing agent will damage ABS fittings 8 Connect the PVC tube from the OUT port via the Non return Valve to the Tapping band Please note do not store the acid drum directly below the RadioNet Outdoor Computer or where fumes may harm equipment Operating the RadioNet Main Menu The RadioNet has three distinct operating modes E System Off E Automatic E Manual You can cycle through these modes by pressing mode de Wie ie MAGNAPOOL System Off In System Off mode all menus and controls are ac
25. ration Always ON actions are commenced immediately when an input signal is present INPUT PORT 1 i i STATUS ON MODE ALWAYS During PROGS actions occur only during a scheduled program TIMER CONTROL actions commence immediately and run for a set period of time INPUT PORT 1 For the input port you need to program SANS ERO Select SANITISER OUTPUT 0 to 100 sp la LOA Select PUMP SPEED if using a Gemini Twin Pump esc i E Select TIMER duration if using Timer Control Mode VET AUI For the output port you need to program JUDE UN Select ON or OFF DAYS OMT WIE Ss esc Select DAYS of operation ol TH P de ON START A FINI SH 10 00PM Select START and FINISH time ll M OH TT PUMP INTERLOCK ON Set the Pump Interlock ON or OFF NB Activating the Pump Interlock feature ensures the Output port is never active if the main pump Gemini Twin or standard single speed is not running 25 On screen Messages Example Input Output Setups NB Power should be turned off to the RadioNet when performing any wiring The voltage activated inputs are rated for a maximum 24V AC DC Do not exceed this rating or the device may be damaged Example 1 Connection to Pool heater for Heat On Demand operation e Connect I O Port 1 or 2 RJ45 with a cat5 cable to a suitable output from the heater 5 24V AC DC using wire pair 5 amp 6 e Enter the menu select Settings then Input Output Control e Selec
26. rom 240 volt power point 2 Remove cell from plumbing do not disconnect cell wiring 3 Place cell on the cleaning stand Tighten the nut to seal and ensure the plates are at the bottom as shown 4 Prepare a 8 1 acid cleaning solution by measuring 2 litres of water into a suitable Use extreme caution when pouring mixture into cell plastic container and then carefully adding 250ml of Hydrochloric Acid and stir thoroughly Carefully pour sufficient cleaning solution into the cell so as to fully cover the metal electrodes Allow to stand for 10 minutes then flush out with clean water If electrodes still show white deposits repeat steps 5 and 6 It is recommended that a warm water detergent solution be used to soak the electrodes at this point if there is any evidence of body fats oils or grease Reinstall the cell ensuring both rubber Q ring seals are in place and indicator arrow points towards water flow Re connect the power pack ie RadioNet plug to 240 volt power point and switch on i NOTE Care must be taken to ensure that the cell wiring does not come into contact with the acid solution This system is fitted with a backup battery and real time clock The time will not require resetting during power outages after performing manual Cell Cleaning TROUBLE SHOOTING GUIDE Trouble Shooting Guide RadioNet does not turn on Power may not be getting to the unit check e that t
27. running The RadioNet Controller will periodically display messages on the screen to let the user know of certain events that have occurred Some of these messages are purely for information whereas some are indications of a system shutdown that requires the user to restart the RadioNet Controller CHECK WATER FLOW No water flow is detected in the Leonardo Cell Action Check for any blockages refer to 038 39 AUXILIARY ON The Auxiliary Socket is currently powered on Action None is required RF communication to the Gemini Pump has been R interrupted MON Action Check pairing with pump or repair both devices connect The RadioNet has detected a high temperature and HGH TEMPERATURE will limit sanitizer output Action None is required The unit will self correct once it cools down A Neva Run Dry event has occurred and the RadioNet SHUTDOWN NRD FAULT has shutdown to avoid damage to the pump Action Ensure the pump is primed restart An Over Temperature event has occurred and the RadioNet has shutdown to avoid internal component SHUTDOWN OVER_TEMP damage Action Allow controller to cool before operating again An Over Current event has occurred and the RadioNet has shutdown to avoid internal component SHUTDOWN OVER CURR damage Action None is required however if this happens regularly consult your Poolrite Professional During Auto mode operation a number of quick reference messages AUT
28. t Input Port 4 e Set Status to ON and Mode to Always On e Set Sanitiser to desired level or 0 for pump only and Pump Speed to desired level Example 2 Automation Controller for heating and pool spa control e Setup as per example 1 above for pump control using a suitable output from the controller 5 24V AC DC e For spa control connect I O Port 1 or 2 RJ45 with a cat5 cable to a suitable output from the controller 5 24V AC DC using wire pair 3 amp 4 e Enter the menu select Settings then Input Output Control e Select Input Port 3 e Set Status to ON and Mode to Always On always active when the spa mode signal is present or During Progs active only during the scheduled program times e Set Sanitiser to desired level 10 20 recommended level for spas and Pump Speed to desired level Example 3 Auxiliary Timer using the Output Port e The Output Port delivers a 12V DC signal of up to 50mA to activate an isolated external device such as a relay or contactor e Connect I O Port 1 or 2 RJ45 with a cat5 cable to a suitable device using wire pair 1 12V DC amp 2 GND e Enter the menu select Settings then Input Output Control e Select Output Port e Set Status to ON and select the desired days of operation e Set the Start and Finish time e Enable the Pump Interlock to limit activation of the Output Port only when the main pump is
29. will be shown on the screen during a Mineral Test to indicate the time remaining until completion TESTING MI NERALS E POSSIBLE LOW If a result of Possible Low Minerals is returned MINERALS please see your pool profession to determine the required mineral dosage TESTING MINERALS Minerals OK indicates the RadioNet MINERALS OK Controller has determined a satisfactory level Mineral concentration is present The SUPER SANITISE feature instructs the RadioNet to run continuously for a set duration with the Leonardo Cell at 80 output This will override any pre set runtime and once complete the unit will return to normal settings US ISE DURATION 08 00h To adjust the Super Sanitise duration hours press A or v then press Start to begin super sanitising SUPERTSANITIISE REMAINING 07 59h Super Sanitise screen display when start is pressed Press stop to end Backwash Mode Feature To access the Backwash Mode select the menu and scroll down to BACKWASH and press enter Dp ECC may Tao Entering the Backwash feature instructs ser male Tm START BACKWASH the unit to guide you through the RINSE backwash process Starting a Backwash will Set the valve to Rinse and then press next automatically pause any currently running program Simply follow the instructions and press Next after completing each step PRESS next TO TURN PUMP ON Press next to turn pump on SET VALVE TO Set t
30. with maintaining the quality of your pool water It is recommended you perform water quality tests regularly STEP 1 SANITISER The RadioNet Outdoor Computer and Leonardo Cell automatically generates chlorine as the sanitising agent The recommended available i e free sanitiser concentration range for MagnaPool is between 0 5 ppm parts per million and 2 0 ppm For salt pools it is 1ppm to 3ppm Follow the instructions in the 2 in 1 Test Kit to measure the free sanitiser level NOTE Please refer to the governing authority tasked with setting relevant standards in your local area STEP 2 pH The pH is the central measure which affects the performance of all other pool water elements required for optimal water quality and bather comfort The pH of your pool must be maintained between 7 2 and 7 6 Follow the instructions in the 2 in 1 Test Kit to measure the pH level If the pH is too high add acid If the pH is too low add pH buffer or pH increaser The 2 in 1 Test Kit also allows you to determine the corrective actions required to maintain the correct pH of your pool Acid Demand Test STEP 3 TOTAL ALKALINITY Total Alkalinity is a measure of several chemicals in the water that help to maintain pH stability It is recommended that a water sample is taken to your local Poolrite professional to measure the Total Alkalinity level The recommended Total Alkalinity range is MAGNAPOOL AND SALT Concrete 100 150 ppm Vinyl lin
31. working appliance Program times are set as per instructions If Gemini Twin pump is used is it paired to the device Pump electrical connection is secure Water chemistry maintained as per instructions Cell has been maintained as per instructions L FE D E o Unit has not been tampered with by un authorised persons If the power supply cord is damaged then it should be repaired by an authorised service agent Filter and Pump Assembly Double adaptors and or extension leads have not been used to connect components The pool water level is maintained to at least 2 3 up the skimmer box opening O Both skimmer box basket and pump basket are clean and correctly in place LI Vacuum cleaning is done with the valve in Filter position only and not in Backwash position O The filter valve handle is not operated while the pump is operating Leonardo Cell Cleaning The Leonardo Cell is designed to operate for extended periods with minimum maintenance The cell cleaning function is performed automatically however manual cleaning on a regular basis will enhance sanitiser production and extend equipment life This is provided in the Fixed Price servicing however here is how to clean the Leonardo Cell SAFETY PRECAUTIONS Ensure that all safety guides for the handling of the acid solution as detailed by the manufacturer are followed 1 Remove Leonardo Cell controller ie RadioNet unplug f