Home

Precision Impedance Analyzers

image

Contents

1. Wayne Kerr s policy is one of continuous development and consequently the product may vary in detail from the description and specification in this publication www waynekerrtest com sales waynekerr info October 2007 Issue A1
2. K Wayne Kerr Electronics Vinnetrow Business Park Vinnetrow Road Runcton Chichester West Sussex PO20 1QH UK Tel 44 1243 792200 Fax 44 1243 792201 Wayne Kerr Electronics 165L New Boston Street Woburn Hsin Tien City MA 01801 6201 USA Tel 1 781 938 8390 Sales 800 933 9319 Fax 1 781 933 9523 Technical data sheet Installation category ll in accordance with IEC664 Pollution degree 2 mainly non conductive Safety Complies with the requirements of EN61010 1 EMC Complies with EN61326 for emissions and immunity Mechanical Height 190 mm 7 5 Width 440 mm 17 37 Depth 525 mm 20 5 Weight 14 5 kg 32 Ib Order codes Description Order code 6505B 1J6505B 5MHz Precision Impedance Analyzer 6510B 1J6510B 10MHz Precision Impedance Analyzer 6515B 1J6515B 15MHz Precision Impedance Analyzer 6520B 1J6520B 20MHz Precision Impedance Analyzer 6530B 1J6530B 30MHz Precision Impedance Analyzer 6550B 1J6550B 50MHz Precision Impedance Analyzer 65120B 1J65120B 120MHz Precision Impedance Analyzer All models supplied with User manual 2m AC power cable Universal component fixture 1 1011 USB memory Options Description Order code Bin handler non isolated B1 Bin handler isolated 24V B2 DC Bias 0 to 40V 0 to 100mA D1 DC Bias 40V to 40V D2 USA TAIWAN Wayne Kerr Electronics Corporation No228 21 Sec 2 Bei Hsin Rd Taipei 231 Taiwan Tel 886 2 2915 8990 Fax 886 2 2915 5775
3. Wayne Kerr Electronics Technical data sheet i Sea WAYNE KERR Meas Bek vs ee Y Ses PASE eeu eee O O 6 3 si 000G Precision Impedance Analyzers 6505B 5MHz 6520B 20MHz 65120B 120MHz Precise high frequency impedance measurements Characterize components to 120 MHz 65120B 0 05 basic measurement accuracy Comprehensive measurement functions Easy to use with large TFT touch screen Intuitive user interface Fully programmable over GPIB e e e Clear graphic displays e Keyboard and mouse optional control Competitively priced The 6500B series of Precision Impedance Analyzers provide precise and fast testing of components at frequencies up to 120 MHz Basic measurement accuracy is 0 05 making the instruments the best in the class The accuracy and versatility makes the precision analyzers the ideal choice for many different tasks and applications including passive component design dielectric material characterisation and manufacturing test www waynekerrtest com 6510B 10 MHz 6530B 30MHz 6515B 15MHz 6550B 50MHz Engineers need to evaluate component characteristics at high frequencies with very high levels of accuracy The 65120B 120MHz Precision Impedance Analyzer is therefore ideal for many demanding tasks combining accuracy and ease of use at an affordable price If a frequency range up to 120MHz is not requ
4. ce General Power Supply Input voltage 9OVAC to 264VAC Autoranging Mains frequency 47Hz to 63Hz Display 8 4 VGA 640 x 480 colour TFT with touch panel Local Printer HP PCL compatible graphics printing Centronics parallel printer port Epson compatible text ticket printing Network Printer HP PCL compatible graphics printing 1 Future enhancement sales waynekerr info Electronics GPIB interface External instrument control 24 pin IEEE 488 connector Remote trigger Rear panel BNC with internal pull up operates on logic low or contact closure USB interface Two Universal Serial Bus Interfaces USB 1 1 compliant VGA interface 15 way D type connector to drive an external monitor in addition to the instrument display Network interface 10 100 BASE TX Ethernet controller RJ45 connector Keyboard interface Standard USB or PS 2 keyboard port Instrument front panel remains active with keyboard plugged in Mouse interface Standard USB or PS 2 mouse port Touch screen remains enabled when the mouse is connected Bin handler option B1 option non isolated 5V or B2 option Isolated 24V 25 way D type connector Environmental conditions This equipment is intended for indoor use only in a non explosive and non corrosive atmosphere Temperature range Storage 20 C to 60 C Operating 0 C to 40 C Full Accuracy 18 C to 28 C Relative humidity Up to 80 non condensing Altitude Up to 2000 m U
5. cy range 6505B 20Hz to 5MHz 6510B 20Hz to 10MHz 6515B 20Hz to 15MHz 6520B 20Hz to 20MHz 6530B 20Hz to 30MHz 6550B 20Hz to 50MHz 65120B 20Hz to 120MHz Frequency step size 0 1mHz Accuracy of set frequency 0 005 AC drive level 10mV to 1Vrms 200A to 20mArms Varies with frequency Signal source impedance 500 nominal DC bias D1 option 0 to 100mAdc bias current 0 to 40Vdc bias voltage D2 option 40V to 40Vdc bias voltage Binning optional 10 bins with absolute and percentage limits 25 way D type interface connector Option B1 non isolated Common OV Bin outputs 0 to 5V nominal with gt 10mA current sink capability Option B2 isolated Common 24V input Outputs 0 to 24V with gt 10mA current source capability www waynekerrtest com Technical data sheet Mode of operation Graphical sweep mode Allows graphical sweep of any two measurement parameters Swept parameters frequency drive level or DC bias Meter mode Allows the instrument to be used as a standard LCR meter Setup Data Up to 20 instrument setups may be locally stored for each mode Measurement connections Four front panel BNC connectors permit three or four terminal connections with the screens at ground potential Measurement accu racy Dissipation factor 0 0005 1 D Quality factor 0 05 Q 1 Q Capacitance Inductance Impedance 0 05 Varies with frequency drive level and measured impedan
6. ired then the other models are available in this range Measurement parameters e Impedance Z Phase Angle Capacitance C Dissipation Factor D Inductance L Quality Factor Q Resistance R Reactance X Conductance G Susceptance B Admittance Y High measurement accuracy Capacitance inductance and impedance basic accuracy is an excellent 0 05 Dissipation factor accuracy is 0 0005 and the quality factor accuracy is 0 05 sales waynekerr info Electronics Graphical sweep of components The 6500B series of Precision Impedance Analyzer are highly accurate high frequency component analyzers with a host of useful features Graphical sweep of two measured parameters is available and displayed on the large clear colour display Swept parameters are frequency drive level and DC bias Display formats available include series or parallel equivalent circuit For single frequency measurements a meter mode is available Variable drive and bias levels AC drive levels up to 1V or 20 mA can be selected to evaluate components in realistic operating environments D1 DC bias option provides 0 to 40V dc bias voltage and 0 to 100mA dc bias current D2 option provides 40V to 40V dc bias voltage External control The GPIB interface is used to control the instrument and read back measured values for applications such as quality control or for archiving purposes An Ethernet interface similarly allows the in
7. lied with all models ensures optimum performance when measuring a wide range of leaded components and devices 1J1012 2 terminal and 1J1014 4 terminal Fixtures allow connection to surface mount devices To provide more connection options a range of optional accessories is available Protection against charged capacitors High precision measuring instruments can be damaged by charged capacitors which can cause costly repairs and unacceptable downtime All the models in the range incorporate protection against charged capacitors Comprehensive and precise component tests at higher frequencies The 6500 series is best summarised by Comprehensive and precise component tests at higher frequencies The instrument is the perfect solution for those who have demanding component measurement needs Trig Trace Setup i Zoom Markers eek 100 00k T o000M di 100 00M Hz Simultaneous plot of impedance and phase displayed against frequency on a clear colour display sales waynekerr info Technical specifications Measurement parameters Any of the following parameters can be measured and displayed AC functions e Impedance Z Phase Angle Capacitance C Dissipation Factor D Inductance L Quality Factor Q Resistance R Reactance X Conductance G Susceptance B Admittance Y Display format Series or parallel equivalent circuit all parameters Test conditions Frequen
8. strument to be controlled and to send out data allowing it to be integrated into many test environments Wide range of interfaces An external monitor or projector may be connected to the instrument The ability to provide a large screen display of measurement results is invaluable in production environments or for teaching and training Instrument control from both a keyboard and mouse is available Any keyboard or mouse with either PS 2 or USB interfaces can be simply connected to provide an alternative method of instrument control and operation Data storage and retrieval All measurement and setup data can be stored using the Ethernet interface or a USB flash memory Setup Data Up to 20 instrument setups may be locally stored for each mode Bin handling option B1 option non isolated 5V or B2 option isolated 24V signals are available through a 25 way D type connector 10 bins can be set using absolute or percentage limits Future Enhancement www waynekerrtest com Technical data sheet Printer outputs Hard copy printouts can be obtained in a number of ways including direct to an HP PCL compatible graphics printer or Epson compatible text ticket printer A networked HP PCL compatible printer may also be used via the Ethernet connection Component connections Four front panel BNC connectors permit three or four terminal connections with the screens at ground potential The 1J1011 Component Fixture supp

Download Pdf Manuals

image

Related Search

Related Contents

Targus EverVu    Samsung M181DN manual de utilizador  - Centre for Advanced Internet Architectures (CAIA)  technical specification of mobile flash butt welding machine    〔 テクニカルデータ 〕  Electronics Technician Volume 3 - San Francisco Maritime National  ESXi Embedded und vCenter Server-Handbuch zur  MODELS LMF-12 TP-15 & TP-16  