Home

Audiofier SEQui2R 1.1 Addendum

image

Contents

1. Audiofier SEQui2R 1 1 Addendum August 2015 The information in this manual is subject to change without notice The software described by this document may not be copied to other media All trademarks are the property of their respective owners and use of them does not imply any affiliation with or endorsement by them Table of Contents Welcome to SEQui2R Audiofier EULA SEQui2R System Requirements Installation Snapshot loading workaround Installing the Update only for owner of SEQui2R 1 0 Important changes in SEQui2R 1 1 update Main Page new features Responsive Keyswitches layers Fixed Key switches Variable Key Switches The Key Scale Controls Panel Save User Function Import Key Scale Function User Presets Slots Bottom Panel Smart Legato Phrasing Function Options Page New Features View Notes Control Step Resonance Control Knob The New System Page Start Options Matrix Scale Options Matrix AUDIOFIER SEQui2R User Manual Welcome to SEQui2R Thank you for buying SEQui2R 1 1 The focus of SEQui2R is to provide a new way of creating sequences without being bound to a arpeggiator type of workflow SEQui2R enables the user to record and perform custom phrases which are altered by SEQui2R engine in order to follow the composition s chords progression But it does not end here As you ll see there are many applications for SEQui2R So please read on as even though the user interface is not overly complicated and does n
2. SEQui2R will wait for a set time if no keys are triggered then SEQui2R will set the first step as the starting note 12 Options Page New Features SEQui2R TEE gt Meni 3 Tune coe Purge 0 00 wh 4 gt GLOBAL OPTIONS VIBRATO CC 2 2 DELAY PAN VIBRATO SPEED 5 SE yy We DIGI RVRB COLOR 3 JU lz VIBRATO DELAY 32 31 STEP FILTER RESO P BEND RANGE 1 MOD FILTER A CC DYNAMICS CC 9 EFFECT AUTOMATOR 1 MOD FILTER B CC VIEW NOTES Cap Normal FILTER B BHVR i FILTER A TYPE 5 SOUNDEXPANSION FILTER B TYPE LOADED SEQuI2R Options The Global Options page offers a few new controls View Notes Control When this value edit is set to 1 every script generated note will be shown on the Kontakt Keyboard On position 0 it will only show the keys that the user presses Step Resonance Control Knob This is a small knob that has been added next to the Step Filter Resonance Value edit Now the user can manipulate the resonance values which are the same for both Group A and B when using the Step Filter Additionally this knob can be CC controlled 13 The New System Page This is a new page which offers exciting new features Start Options Matrix Start Options START OPTIONS MATRIX FROM KEY STARTING NOTES co 3 5 7 This matrix includes 4 slots where to set the optional starting notes When these values are set the optional start can be triggered and changed via keyswitch see
3. 1 activates the Optional Start function while G 1 deactivates it e Green keys A 1 B 1 these keys control the Legato function It overrides the Optional Start function They can be pressed both while idle or while a phrase is already playing B 1 activates the Legato function while A 1 deactivates it e Red keys A 0 BO these keys control the Tempo Behaviour see below Tempo Behaviour Menu o A 0 doubles the speed of the ongoing phrase o BO halves the speed of the ongoing phrase Variable Key Switches Pitch Mod NAIPATA The following keys will show and be active only in Play Mode Not in Recording Mode e Red keys CO D 0 These keys trigger the four optional starts See System Page Controls e Purple Keys E0 G 0 EO activates the scale selected in the Key scale control Menu From FO to G 0 they trigger the four scale variations System Page Controls Pitch Mod TTAN The following keys will show and be active only in Recording Mode Not in Play Mode e Red key CO it s the pause rest key To be used while recording a phrase e Purple keys DO AO these keys select the note value while recording a phrase They override the Note Value Menu on the GUI The values are from 32nd note DO to 2 4 AO The Key Scale Controls Panel The PRESETS Menu now includes a few more items Apart from the original choices of keys scales there are a few new features Fm H Gm H Dirn HW Dirn
4. WH Whole C Whole C Saue User User 1 User 2 User 3 User 4 User 5 User 6 User 7 User 8 User 9 i User 10 Import Save User Function When this item is selected two new items appear on the place of the Key Scale Power switch KEY CONTROLS Loc 1 Saue User Semi Dwn o Location Number value edit this allows the user to select one of the ten user locations to store the user Key Scale preset o Save led button this small button opens a dialogue window which will ask for a filename for the user preset to be saved After Save is clicked the newly saved user preset will be recallable via the The PRESETS Menu 10 by clicking the correspondent user preset number that was previously selected with the Location Number value edit Import Key Scale Function By clicking this item two new items appear on the place of the Key Scale Power switch KEY CONTROLS Loc 1 Import Semi Dwn o Location Number value edit this allows the user to select one of the ten user locations to which import an user preset o Import led button this small button opens a dialogue window which will show a choice of previously saved presets After Open is clicked the newly imported user preset will be recallable via the The PRESETS Menu by clicking the correspondent user preset number that was previously selected with the Location Number value edit User Presets Slots These will recall any user preset saved thr
5. above new Variable Keyswitches The label From Key is just a reminder of the first keyswitch that triggers the first optional starting note and it cannot be changed Scale Options Matrix Scale Options SCALE OPTIONS MATRIX FROM KEY KEYS SCALES FO C Am D Bm E C m F Dm This matrix includes 4 menus where to set the optional four key scales When these values are set the optional start can be triggered and changed via keyswitch see above new Variable Keyswitches 14 Midi Notes Drag amp Drop MIDI DRAG AND DROP CAPTURE This brand new feature allows the user to drag a Midifile containing the full recorded midi performance on the preferred DAW 1 Record your phrases in your DAW as you would normally using SEQui2R 2 Press the Capture button and place your DAW s playhead just before the first keyswitch which triggers the first phrase you played The button will light up 3 Play the whole performance or a few bars of it 4 Press again Capture button to deactivate it 5 A Midifile icon appears after the capturing has finished 6 Click on the Midifile Icon and drag it on your DAW where you have prepared a midi track or an instrument track A new midi region will be created containing all the midi notes SEQui2R has generated Only midi notes will be exported No Midi CC or Pitch Bending CC If SEqui2R Midi performance is happening over a Bpm change it s recommended to temporarily move SEQui2R s m
6. ction utility to unpack the rar or zip archives whichever you received This library is intended for use with MIDI controller keyboards ideally with 76 keys Due to the layout of SEQui2R it is recommended to have a few MIDI controllers sliders or knobs available to take fully advantage of SEQui2R capabilities MAC RECOMMENDED SYSTEM e Mac Pro Quad Core Intel Xeon 2 66GHz or higher 16GB RAM or more Mac OSX 10 7 or later SSD Solid State Drive NI Kontakt 5 5 PC RECOMMENDED SYSTEM e Intel Core 2 Quad or AMD Quad Core 2 66GHz or higher 16GB RAM or more 64 bit Windows Host Sequencer Sound card with ASIO drivers SSD Solid State Drive NI Kontakt 5 5 Installation Locate your downloaded file and use a zip extraction utility to uncompress SEQui2R SEQui2R makes use of Kontakt s snapshots feature Please refer to Kontakt s user manual to learn how to load and save snapshots To install SEQui2R factory s snapshots copy SEQui2R folder located inside Snaphots folder to On Mac OS X Macintosh HD Users Your Name Documents Native Instruments User Con tent Kontakt On Windows C Users Your Name My Documents Native Instruments User Content Kontakt Do not copy the folder Snapshots but only the folder named SEQui2R into the path above Failing to do so will result in the incapacity of loading SEQui2R factory patches While this may be a big handicap this library can still be used without them but the user wi
7. idi region to a steady time part of the arrangement or just after the end of it and the capture the performance as the tempo change will not be recorded and the sync will not be kept Bpm speed does not make any difference as long as there is no Bpm change during SEQui2R midi capturing The Exported Midi performance will adapt to the tempo change once is placed again in the correct song position 15 A BIG THANKS GOES TO ICE NEAL OSCAR LO BRUTTO ALEX LOFOCO ENRICO PINNA MARIA GRIG V I CONTROL FORUM MEMBERS AND GOD
8. ll have to create his own patches snapshots from scratch Snapshot loading workaround Note In some PC configurations the snapshot Kontakt folder is not created when Kontakt is installed but only when the user creates his first snapshot Therefore the path to the snapshots does not work if no user snapshots has ever been created prior to SEQui2R installation If you do not see a Kontakt folder in the snapshots path indicated in the manual please use this workaround 1 Do not move SEQui2R snapshot folder in the suggested path yet 2 Load SEQui2R in Kontakt 3 Follow Kontakt instructions on how to save a snapshot and save a dummy snapshot with any name 4 Pls check that you see it afterwards in the snapshot list 5 Open Kontakt s hood clicking on the wrench and click on instrument options 6 Select the tab Snapshots and click on show Kontakt should point you directly to the folder it wants you to put the snapshots in 7 8 Drag all the folders that you find inside SEQui2R snapshot folder The file INIT and the folders Electronic Organic Guitars and Rhythms Now check the snapshot list again and you should see all presets snapshots Installing the Update only for owner of SEQui2R 1 0 In order to update SEQui2R please follow these simple instructions 1 Back up temporarily the files SEQui2R nki SEQui2R_rsrc nkc SEQui2R_rsrc nkr and INIT nksn from the snapshots folder see above Put in the SEQui2R f
9. older the new SEQui2R nki SEQui2R_1_1 nkr and SEQui2R_1_1 nkc Put INIT_1_1 nksn where you previously had INIT nksn Load SEQui2R into Kontakt 5 5 Important changes in SEQui2R 1 1 update The following is a list of all major additions that make SEQui2R even better Responsive Keyswitches layers Ten user slots to save key scales user presets Import and export of user key scales presets Intelligent Legato Phrasing Start Step Filter MIDI CC controllable Resonance Knob Generated notes view System Page Four additional optional phrases start points user selectable and triggerable via keyswitches Four additional user selectable key scales triggerable via keyswitches Total Phrase Performance Midi Notes Drag amp Drop Main Page new features Responsive Keyswitches layers Pitch Mod eee As you ll notice Kontakts graphic keyboard color layout has been changed to reflect new features Fixed Key switches These keys will not trigger any sound but they will activate different functions e Green keys C 1 G 1 these keys activate each of the 8 available phrases per patch They can be pressed both while idle or while a phrase is already playing These keys override the 8 Sequences Selectors and the Recall Button altogether e Red key G 1 A 1 these keys control the Optional Start function It overrides the legato start function They can be pressed both while idle or while a phrase is already playing A
10. ot comprise many different pages a few important feature might not be apparent on the GUI at a first glance Audiofier EULA BY DOWNLOADING AND INSTALLING SEQui2R 1 1 YOU AGREE TO THE FOLLOWING SEQui2R library is licensed not sold to you This license is personal and non transferrable YOU MAY use SEQui2R in your own compositions including library music and or commercial work for clients media without any restrictions or additional fees YOU MAY install SEQui2R on multiple computers of yours as long as you are using the library and you are not sharing giving lending your license with others YOU MAY NOT make copies of this library as a whole or in part with the intent to re distribute sell or give them away this includes making available any of the content on a network e g through internet file sharing services or pirate sites YOU MAY NOT re use or re package any of SEQui2R content in another virtual instrument or sample library Installing the SEQui2R library implies that you agree to the above terms and conditions 2015 SEQui2R System Requirements To install SEQui2R you need at least 5GB of hard disk space over 10GB uncompressed While a fast hard drive is required a solid state drive is highly recommended in a fast computer due to SEQui2R s high number of samples and demanding CPU engine SEQui2R requires the retail Native Instruments Kontakt 5 5 SEQui2R_ will not work with Kontakt Player You will need an extra
11. ough the Save User Function Each snapshot can include ten unique user presets as they are saved or imported for each patch snapshot The user can import in one patch snapshot scales saved in other patch snapshots 11 Bottom Panel This panel has a few new features Utility Sequence e OPTIONAL START As before this value edit allows to select from which step the optional start feature will begin In conjunction with the new Optional start keyswitches this value edit will show from which step the phrase is starting Smart Legato Phrasing Function SEQui2R now recognizes when the user has left the keys for a specific length of time and starts the following phrase from its first step Before this was not possible and the user had to switch the legato function off in order to start the following phrase from the first step and subsequently legato on in order to activate it Now the legato keyswitch can be set at the beginning of a phrase and left on until desired providing there is a sufficient gap of time between the last legato line and the following phrase that needs to start on the first step Utility Sequence Leq On e LEGATO START With legato activated a knob appears beside Legato on label This knob should be used with care It sets the Time Gap SEQui2R waits before deciding to start the phrase from the first step when triggered again In other words once the user releases his hands from the keyboard

Download Pdf Manuals

image

Related Search

Related Contents

Capitolato speciale di appalto  VITA BULLETIN 51025  User Manual - Magnum Dimensions  OWNER`S MANUAL  User Manual - TDJ Australia  FRN-2108 Écriture pour enfants et adolescents  MANUEL D`UTILISATION  Equip 24-Port Cat.6 Shielded Patch Panel  Limits Operating Instructions Product Registration Form    

Copyright © All rights reserved.
Failed to retrieve file