Home
user manual daisy color
Contents
1. Pacifier clinical thermometer Geratherm Medical AG GB Geratherm daisy color GT 126 Germany C 0197 INSTRUCTION FOR USE Please read carefully before using FEATURES With visual fever alarm With orthodontic nipple design made of hard wearing silicon Compact accurate and durable LSI Large Scale Integration device Sensitive temperature sensor for fast results Automatic power off wihtin 30 seconds Easy to read large LCD liquid crystal display The device is waterproof No mercury inside PARTS DESCRIPTION LCD display with fever alarm indicator ONOOaRWNDNY sensor Power Button SPECIFICATIONS Measuring range 32 0 43 9 C below 32 0 C display L C above 43 9 C display H C Intended use Measurement of body temperature Resolution 0 1 C F Accuracy 0 1 C 34 0 C to 42 0 C 0 2 C other range 0 2 F 93 2 F to 107 6 F 0 4 F other range Display Liquid crystal display 3 1 2 digits Battery included CR2032 3 V Energieverbrauch 0 15 milliwatts in measurement mode Battery life More than 160 hours of continuous operation IP classification IP27 Protected against solid foreign objects with a diameter of 12 5 mm and protec tion against temporary immersion Dimensions 60 mm x 50 mm x 42 mm Weight Approx 23 grams including battery Beeper Approx 5 secs sound signal when end temperature reached Memory Built in memory enabling di
2. e battery 6 7 Avoid taking temperature in 30 minutes after physical exercises bathing or dining Do not store use and transport the unit under direct sunlight at a high temperature or in high humidity or dust Performance may be degraded 8 Stop using the thermometer if it operates erratically or if the display malfunctions 9 If the thermometer has been stored at below freezing temperatures allow the thermometer to warm naturally to room temperature before using 10 Before every use check the pacifier thermometer and especially the silicon nipple for signs of damage or wear 11 Do not use damaged pacifier any more 12 Always maintain the minimum time required for measurement which is indicated by the acoustic signal 13 The pacifier thermometer is intended only for oral measurement of body temperature in children up to 3 years of age 14 It is not suitable for constant sucking 15 Under specific conditions crying breathing through the mouth the displayed temperature may be too low 16 In case of doubt and signs of fever temperature higher than 38 5 C flushed appearance perspiration unwilling ness to drink restlessness measure the body temperature rectally BATTERY DISPOSAL For safety reasons the battery cannot be exchanged 1 When the symbol C7 appears the unit should be disposed of Discard the battery before disposing of the unit 2 Separate the panel sticker from the unit AAN 3 Use a screwdrive
3. ower than actual body temperature readings Special Features Last temperature memory recall Press and hold the ON OFF button while turning on the unit for more than 3 seconds The last measured temperature will appear with the letter M under the C sign Visual fever alarm fever alarm indicator If the temperature registers higher than 37 5 C the display will have a red background light for 35 9 T 5 seconds lt _ lt 36 0 T 37 1 A NOTE 37 2 T 37 4 Children should be attended by an adult during the entire temperature recording process After use the 37 5 T7 43 9 digital pacifier thermometer should be stored in a safe place out of reach of young children CLEANING INSTRUCTIONS Disinfect the thermometer by wiping the teat with the sensor and the shield with a cloth that has been immersed in a household antiseptic solution such as rubbing alcohol 44 0 T DISPOSAL Observe the applicable regulations when disposing of the thermometer and batteries This thermometer must not be disposed of together with domestic waste All users are obliged to hand in all electrical or electronic devices regardless of whether or not they contain toxic substances at a municipal or commercial collection point so that they can be disposed of in an environmentally acceptable manner Please remove the batteries before disposing of the thermometer Do not dispose of old batteries with your household wa
4. r to do it 4 Discard the battery A Note Discard old battery carefully out of reach of young children Do not dispose of the battery in a fire It may explode A Note Replacing the battery may damage the unit HOW TO USE 1 Remove the protective cover 2 Place the pacifier nipple in the child s mouth like a normal baby pacifier Be sure the child keeps the thermometer in his mouth during measurement and keep the child s mouth closed as much as possible A Note Drinking or eating prior to use may affect the reading 3 Start with the measurement after abt 3 5 minutes by pressing the ON OFF button The display will read with fever alarm indicator flashing red gt yellow gt green for 2 seconds 4 The display will show L C with C flashing 5 Once the degree sign C stops flashing the measurement is ready and the correct temperature is displayed An alarm will sound for approximately 5 seconds after measurement 6 The fever alarm indicator colored backlight will light up for 5 seconds the color depending on the temperature measured It is recommended to leave the thermometer in the baby s mouth to allow the nipple to warm up and obtain a more accurate reading 7 The unit will automatically turn off in approx 30 seconds However to save energy it is best to turn the thermome ter off immediately after the temperature has been noted A Note Oral temperature readings are often 0 5 C l
5. splay of the previously measured value Shut off Automatic shut off in approx 30 seconds Working Conditions Temperature 10 C to 40 C 50 F to 104 F Humidity 15 to 95 R H It is only is possible to measure temperatures that are above the ambient temperature Storage Conditions Temperature 25 C to 55 C 13 F to 131 F Humidity 15 to 95 R H Guarantee of Quality EN 12470 3 Clinical thermometers Part 3 Performance of compact electrical ther mometers with maximum device Geratherm is certified in accordance with Council Directive 93 42 EWG and EN ISO 13485 and is entitled to affix the CE mark C 0197 Notified Body T V Rheinland LGA Products GmbH Electromagnetic compatibility EMC The present medical product is a device with extremely high degree of noise immu nity Therefore the enclosure with the EMC tables was not printed out AN PRECAUTIONS l Use of this instrument is not intended as a substitute for consultation with your physician Prolonged high fever requires medical attention especially for your children Please contact your physician 2 Child s temperature shall be taken under adult s surveillance 3 Keep out of the reach of unsupervised children Choking resulting from a child swallowing a small part that has become detached from the thermometer 4 Do not boil bite bend drop or disassemble this thermometer 5 Do not attempt to disassemble the unit except to replace th
6. ste but at a battery collection station at a recycling site or in a shop LIMITED WARRANTY This thermometer is guaranteed for 2 years from the date of purchase against manufacturer s defect under normal use The warranty does not cover damage to your unit due to improper handling Following the directions closely will ensure years of dependable operation In case of professional use the manufacturer recommends to verify the accuracy by an authorized laboratory every 2 years in Germany this is compulsory SYMBOLINDEX Follow instructions for use Type BF applied part Keep dry The device must not Caution Read the be disposed of with i Manufacturer instruction manual household waste Store between 15 and Store between 25 C Batch code 95 R H and 55 C mm yyyy month year Geratherm Medical AG Fahrenheitstrasse 1 98716 Geschwenda Germany www geratherm com C 0197