Sterilox Dental System User Manual

image

Contents

1. 800 604 1879 Sterilox Dental Operating Procedures Maintenance Generate Sterilox Solution Replacing the Fuses The two fuses located on the back of the Sterilox Dental Generator are the only user Press and continue to hold down the gray dispense button to generate Sterilox serviceable parts Solution Release the dispense button to stop the generation of Sterilox Solution Never generate less than 250 ml of the Sterilox Solution to ensure that it is within specification Use the Sterilox Solution as directed on the following page CAUTION Read the fuse label located on the back of the Sterilox Dental Generator before fuse replacement Replace the fuses only with Generate additional Sterilox Solution as required emptying the waste container when those of the same type and rating The Sterilox Dental Generator is necessary protected by two 3 15A 250V time delay fuses Ensure an Adequate Electrolyte Level 1 Power off the Sterilox Dental Generator and remove the cord If the Sterilox Electrolyte Solution level runs low the Generator will cease generation of Sterilox Solution and the yellow LOW light on the Reservoir Status will be illuminated Replenish the electrolyte ensure that the green OK light on the Reservoir 2 With a small flat screwdriver open the door to the power entry module as shown in the upper photo to the right Status is illuminated and press and continue to hold the gray Dispense Button to 3 With t
2. sterilox dental sterilox dental PuriCore Inc 508 Lapp Road Malvern PA 19355 800 604 1879 484 321 2700 www puricore com 0001 0102 Rev B PuriCore sterilox dental LIMITED WARRANTY STERILOX DENTAL SYSTEM Includes Sterilox Generator Model 9000 0010 Generator Sterilox Electrolyte Solution Electrolyte and Sterilox Solution Solution and together with Electrolyte Products PuriCore hereby warrants that the Products shall for designated shelf life or use by date on the label as applicable conform in all material respects to the specifications therefore as set forth in documentation accompanying the Products and be free from any material defects in materials and or workmanship This limited warranty applies only to Products used in accordance with the Generator User Manual and instructions for the Sterilox Dental System PuriCore hereby warrants that the Sterilox Generator shall for a period of one year from the date of purchase conform in all material respects to the specifications therefore as set forth in PuriCore s documentation accompanying the product and be free from any material defects in materials and or workmanship PuriCore at its sole discretion will repair or replace any item covered by this warranty with equivalent units and or parts The aforementioned warranties collectively Warranty apply solely to the original purchaser and are not transferable Disclai
3. Wash the containers separately from the Sterilox Dental Generator Use a solution of mild liquid detergent and warm tap water e Do not apply cleaning solution directly to the Sterilox Dental Generator Slightly dampen a cotton cloth paper cloth or sponge with a solution of mild liquid detergent and warm tap water Clean all exterior surfaces of the Generator Once cleaned the surface can be wiped with a dry cloth 800 604 1879 Sterilox Dental Precautions Sterilox Dental Solution Applications General Operating Precautions Hospital Grade Hard Surface Disinfection The Sterilox Solution is a hospital grade hard surface disinfectant Pour full strength Sterilox Disinfectant Solution into a spray bottle Apply the disinfectant label provided in the Starter Kit to the exterior of a spray bottle and ensure all staff are properly trained in the use of Sterilox Solution as a hard surface disinfectant e Add Sterilox Electrolyte Solution to the Sterilox Dental Generator only when the Sterilox Dental Generator is powered ON and the yellow LOW light on the Reservoir Status is illuminated e Always pour the entire contents of the Sterilox Electrolyte Solution bottle into the 1 Forheavily soiled surfaces a pre cleaning step is required Generator The green OK light on the Reservoir Status indicates that there is 2 Hold the plastic spray bottle 6 8 inches from the surface to be treated and spray enough Sterilox Electrolyte Solution in the reser
4. GENERATOR AND OR PRODUCTS IN ANY MANNER THAT IS INCONSISTENT WITH THE INSTRUCTIONS CONTAINED IN THIS USER MANUAL OR ANY MATERIALS DOCUMENTATION OR LABELING REGARDING THE STERILOX DENTAL SYSTEM OR WITH ALL APPLICABLE SAFETY REGULATORY AND INDUSTRY SAFETY STANDARDS OR THEIR EQUIVALENT Copyright 2010 PuriCore Inc All rights reserved PuriCore and Sterilox are registered trademarks of PuriCore Inc All other trademarks are property of their respective owners Except for the creation of back up copies this guide may not be copied in whole or in part without the express written consent of PuriCore Inc This product is covered by Patent No 7 828 942 and additional pending patents PuriCore Inc 508 Lapp Road PuriCore Malvern PA 19365 800 604 1879 484 321 2700 Sterilox Dental 800 604 1879 800 604 1879 Sterilox Dental Warranty and Limitation of Liability sorornnrrennnrrernnrrrnrnnrrnnnnerennner 2 Fat goe CHO g PR E T 4 SCAN ATION and I CITING EEE 6 Opeiaung lad 0101 10 OE 8 Sterilox Dental Solution Applications arrrrvrrnnrrrvrnnnrrrerrnnnrrrnnnner 10 isch RE 12 Maintenance EE n 15 wm 18 BUDDIES amp ACCCSSON enerne aetema ure iles eH eubcib ues E 19 Fo 20 Technical Inf rmatiOn 21 My Sterilox Generator Serial Number Sterilox Dental 800 604 1879 800 604 1879 Sterilox Dental Introduction The Sterilox Dental System manufactures a safe natura
5. prevent getting solution in the eyes 3 Slowly expel the Sterilox Solution from the needle and continuously flush the root canal for 1 minute working the needle in an up down motion being careful not the extend past the root canal apex 4 Allow 1 ml of Sterilox Solution to remain in the root canal for 5 minutes 5 Placea hand file of appropriate diameter to working length and mechanically agitate the Solution 6 Remove the Sterilox Solution by suction 7 Atthis step the clinician may choose to use an appropriate solution to aid smear layer removal 8 Repeat steps 1 7 at the clinician s discretion 9 Rinse the canal continuously for 1 minute with Sterilox Solution and dry the canal thoroughly before sealing and obturation Sterilox Dental 800 604 1879 800 604 1879 Sterilox Dental Precautions Warnings and Cautions For your protection read these safety instructions completely and keep this guide for further reference Observe and comply with all warnings cautions and instructions placed on the Sterilox Dental Generator or described in the installation and operating instructions UL Approved This device has been tested as laboratory equipment in accordance with applicable UL Underwriters Laboratory specifications and meets specified electronic leakage requirements J Warnings This symbol located on the Sterilox Dental Generator is intended to alert you to a possible electrical shock hazard e Use only a
6. Discard any unused refrigerated Sterilox Solution after 48 hours Discard any unused refrigerated diluted Sterilox Solution for Daily Maintenance after 96 hours Sterilox Solution Appearance and Odor It is normal for the Sterilox Solution to appear slightly cloudy at times The cloudiness will dissipate in a few minutes Sterilox Solution will have a mild chlorine odor 800 604 1879 Sterilox Dental Sterilox Dental Solution Applications Maintenance Disinfection of Dental Unit Water Lines To disinfect dental unit water lines an initial purging is required followed by daily maintenance as detailed below Purging Dental Unit Water Lines This step is a mandatory initial purge of the dental unit water lines and if line has been inactive for 1 month or more 1 Ensure that all hand pieces electric motors air water tips and couplings are removed prior to the primary disinfection of the dental unit water lines 2 Empty the dental unit water bottle and empty or air dry the lines 3 Fill the water bottle with the Sterilox Solution 4 Flush each dental unit water line with approximately 250 ml of Sterilox Solution NOTE Leave a small amount of Sterilox Solution in the bottle Do not allow the lines to run dry 5 Keep the Sterilox Solution in the lines for four hours 6 After four hours air purge the dental unit water lines until all Sterilox Solution is removed 7 Refill the dental unit water bottle with Sterilox Solu
7. Sterilox Dental Generator in an upright position reach under the bottom of the unit to Remove the plug with a flat access the drain plug screwdriver With a flat screwdriver remove the plug by turning the plug head counterclockwise When the Sterilox Electrolyte Solution stops flowing slightly tip the unit side to side to empty the tank of residual electrolyte solution When the draining is completed re insert the plug into the drain hole and turn it clockwise until fully inserted DP Do not over tighten the plug Over tightening the plug Empty the reservoir tank of all can strip the threads and cause the Sterilox Electrolyte Me Eee Solution to leak when refilling Always replace the plug immediately after draining the Sterilox Electrolyte Solution Sterilox Dental 800 604 1879 Operating Procedures WARNING For external use only Not for injection HANDLING Sterilox Solution is non irritating and non sensitizing to skin and eyes and requires no special handling precautions STORAGE Refrigerate unused Sterilox Solution in a sealed air tight plastic or glass container Store Sterilox Solution up to 48 hours Store Diluted Sterilox Solution for Daily Maintenance up to 96 hours INGREDIENTS Water 99 574 Sodium chloride 0 4 Hypochlorous acid 0 025 Sodium chlorate 0 001 DISPOSAL Sterilox Solution is safe to the environment No special disposal considerations are required for unused Sterilox Solution
8. e 5000 5189 Chlorine Test Strips 6000 6017 Water Bottle Uptake Tubes 6000 6018 6000 6016 Sterilox Dental Beaker Sterilox Hard Surface Disinfectant Container Label 0001 0142 800 604 1879 Sterilox Dental Service Installation and Priming Sterilox Dental Generator Service If the Sterilox Dental Generator requires service follow the instructions below 1 Call PuriCore Customer Service at 800 604 1879 2 Have the Sterilox Dental Generator serial number located on the back cover of the Generator available to give to the Customer Service Representative 3 If the PuriCore Customer Service Representative cannot solve the problem over the phone you will be given instructions on how to return the Sterilox Dental Generator If the Generator qualifies under the original factory or extended warranty terms and conditions a replacement unit will be shipped to you at no charge The replacement Sterilox Dental Generator will have the remaining balance of the original or extended warranty coverage 4 It is imperative that the reservoir tank be completely drained before shipping the Sterilox Dental Generator Drain the reservoir tank as described in the Draining the Reservoir Tank section on page 16 of this User Manual 5 Place the Sterilox Dental Generator in the original shipping box or in the box provided by PuriCore Customer Service 6 Return the Sterilox Dental Generator as instructed by the PuriCore Customer Service Re
9. e dental unit water bottles must be of medical grade silicone or neoprene If necessary replace these uptake tubes inside the dental unit water bottles with the uptake tubes provided in the Sterilox Starter Kit 3 Power On the Generator Select a level surface on which to operate the Sterilox Dental Generator The Generator should be positioned for easy access to the rear power switch Connect the power cord to the back of the Sterilox Dental Generator and plug the other end into an AC power outlet with a grounded receptacle Press the ON OFF switch on the rear switch to the On position Observe that the yellow LOW light on the Reservoir Status Panel is illuminated Power on the Generator 3 Install the Containers Insert the dispense container in the top well of the Sterilox Dental Generator Ensure that the waste extension sleeve 1 2 inch clear Teflon tube is placed over the waste spout Install the sleeve on the waste An extra sleeve has been provided for your convenience spout Insert the waste container in the bottom well Sterilox Dental 800 604 1879 Supplies amp Accessories Ordering Sterilox Dental Supplies and Accessories To order Sterilox Dental supplies call PuriCore Customer Service at 800 604 1879 PuriCore Part Number Sterilox Electrolyte Solution Case of Four Bottles 6000 6006 Palintest 1000 Chlorometer Duo Meter 3000 3001 Palintest Tablets 3000 3013 Replacement Waste Spout Sleev
10. ectrolyte Solution Dry the well s with absorbent paper towel Ensure the containers are installed as described in this User Manual Empty the waste container regularly If the Sterilox Generator continues to leak ensure that the waste extension sleeve is placed properly over the spout Discontinue use immediately and call PuriCore Customer Service Test the Sterilox Solution as described on in Operating Procedures in this User Manual If the AFC level is not within the recommended range call PuriCore Customer Service Turn the Generator off and back on If the problem continues call PuriCore Customer Service 800 604 1879 Introduction Sterilox Solution Definitions Sterilox Electrolyte Solution Sterilox Solution Waste Product The Sterilox Electrolyte Solution is used by the Sterilox Dental Generator to make the Sterilox Solution The use of any other solution is unauthorized and will void any applicable product warranty The Sterilox Solution hypochlorous acid HOCI is produced by the Sterilox Dental Generator and is used to disinfect and maintain dental unit water lines to disinfect hard surfaces and to cleanse root canals following endodontic procedures The waste product dilute sodium hydroxide NaOH is produced by the Sterilox Dental Generator and is collected in the waste container in the lower well This product should be emptied into a sink drain when necessary The waste product is safe for dis
11. he same small flat screwdriver pull out the fuse holder complete the generation of Sterilox Solution assembly as shown in the lower photo to the right o A Open door of the Test the Sterilox Solution 4 Replace the blown fuses P entry module Available Free Chlorine AFC Concentration To test the Sterilox Solution for 5 Reinstall the fuse holder assembly and plug in the power cord proper concentration use one of the two following methods Power on Sterilox Dental Generator and proceed as normal e Free Chlorine Check Test Strips When using the test strips follow the Directions for Use provided which depict the acceptable color range e Palintest 1000 Chlorometer Duo Meter When using the meter follow the Fuse holder operating procedure provided with the instrument assembly The recommended concentration range is 180 260 ppm AFC Contact PuriCore Customer Service if your Sterilox Solution is out of specification To order these test strips or the Palintest meter see the Supplies and Accessories page in this User Manual Sterilox Dental 800 604 1879 800 604 1879 Sterilox Dental Maintenance Draining the Reservoir Tank If the Sterilox Dental Generator needs to be shipped or transported you must drain the Sterilox Electrolyte Solution as follows 1 Power off the Sterilox Dental Generator and remove the power cord Carefully position the Sterilox Dental Generator over the Sink While maintaining the
12. l and effective ready to use solution formulated as a disinfectant to remove biofilms and harmful pathogens in dental unit water lines DUWL as a hospital grade hard surface disinfectant and as an endodontic cleanser following root canal procedures The Sterilox Dental System includes the Sterilox Dental Generator which produces a hypochlorous HOCI solution Sterilox Solution This solution is non cytotoxic non mutagenic and has shown no contact hypersensitivity and no oral toxicity Shipping Contents The Sterilox Dental System consists of a Sterilox Dental Generator the precursor Sterilox Electrolyte Solution and the Sterilox Starter Kit as shown below Sterilox Dental System Sterilox Generator Sterilox Electrolyte Solution One case of four bottles Dispense Container ia uh Sterilox Starter Kit Uptake Tubes Free Chlorine Test Strips Beakers Sterilox Hard Sur Waste face Disinfectant Container Label Container User Manual Power Cord 800 604 1879 Sterilox Dental Technical Information Electrical Supply Mains Nominal eee 100 240V 50 60 Hz M aximUm CUNEN EE E E ere ee eT S oM 3 5 amps F ses 2 used TMS ee EEA NETERA REE EREE 3 15A 250V time delay Supply Voltage TN 10 of Nominal Environmental PETE Room temperature Storage Temperature Sterilox Electrolyte Solution rrrrrrrrrrnrrrrnnnnnnrrrrrrrrrnnnnnnnnn 10 30 C 50 85 F Operations UY AV PE Unit can operate c
13. mer and Limitation of Liability THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED AND PURICORE EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ALL OTHER WARRANTIES ARE EXPRESSLY DISCLAIMED IN PARTICULAR AND WITHOUT LIMITING THE FOREGOING LIMITED WARRANTY AND DISCLAIMER PURICORE SPECIFICALLY DOES NOT OFFER AND HEREBY DISCLAIMS ANY REPRESENTATION OR WARRANTY THAT THE STERILOX DENTAL SYSTEM BE USEFUL FOR OR RESULT IN TREATMENT DIAGNOSIS OR DETECTION OF ANY DISEASE ILLNESS INFECTION OR CONDITION THE EXCLUSIVE REMEDY FOR ANY BREACH OF THIS LIMITED WARRANTY SHALL BE AT PURICORE S OPTION REFUND OF THE PURCHASE PRICE REPAIR OR REPLACEMENT WITH THE IDENTICAL PRODUCT OR CLOSEST SUBSTITUTE THEN SOLD BY PURICORE IN NO EVENT SHALL PURICORE BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES REGARDLESSOF THE BASIS FOR THE CAUSE OF ACTION USE THE GENERATOR AND PRODUCTS ONLY AS DIRECTED FOLLOW ALL INSTRUCTIONS CAREFULLY HEED ALL WARNINGS AND OBEY ALL APPLICABLE LAWS REGULATIONS SAFETY AND INDUSTRY STANDARDS AND PRACTICES DO NOT INSTALL OR OPERATE THE GENERATOR AND OR PRODUCTS IF YOU HAVE NOT REVIEWED THIS MANUAL OR IF ANY INSTUCTIONS ARE UNCLEAR OR UNFAMILIAR TO YOU STERILOX SHALL NOT BE LIABLE FOR INJURIES DAMAGES OR LOSSES OF ANY KIND SUSTAINED AS A RESULT OF USING THE
14. n approved power cord set If you are not sure as to the proper power cord to use with your Sterilox Dental Generator contact PuriCore Customer Service e Do not operate the Sterilox Dental Generator if there is damage to the power cord or plug if the Generator is malfunctioning or if it has been dropped or otherwise damaged Never attach or detach the Sterilox Dental Generator from a source of AC power with wet hands Do not directly touch or apply power or disconnect power if the power cord is wet Use a dry glove or towel to avoid a possible shock hazard e Never pull on the power cord to remove the plug from an outlet Grasp the plug and pull to disconnect e Do not attempt to service the Sterilox Dental Generator yourself as opening the Generator housing risks a shock hazard that could result in serious injury or death Opening the Sterilox Dental Generator for any reason will void any applicable product warranty Contact PuriCore Customer Service to return the Sterilox Dental Generator for repair Do not allow Sterilox Electrolyte Solution to spill over the back of the Generator when filling Sterilox Dental 800 604 1879 Precautions A N Cautions Be certain to read and understand the important safety and operating information below before proceeding Monitor the waste container levels and dispose the waste product as needed When disposing the waste product avoid contact with eyes skin mucous membranes or clothing Do no
15. ontinuously Fluid Capacity NANTES 4 0 Liters BE 66 1 IG onei eii tunc i blink RU Ser IRR Des Pb Pu Ep Mis eu aar aA Ua PEE dese E bpb CAKE ii ei 500ml WAY ABTS CONTAIN a e a r r e E i nr adani 150ml Physical Characteristics Weight with no Becfolfe E 5 2 Kg 11 5 Ibs Weight with 4 0 liters of Electrolyte errrrrrrnnnnnnrrrrrrrrrrnnrrrnnnnnnnrrrrrrrrernnnnnnnnnnnnserrsnnnnne 9 2 Kg 20 3 Ibs pz o RE TOER EDER EEE DN 323 mm 12 7 KA LG EE REE E NKO 381 mm 15 B o DER Ur 206 mm 8 11 800 604 1879 Sterilox Dental Troubleshooting PuriCore Customer Service 800 604 1879 Have your Sterilox Dental Generator serial number ready located on the back cover Problem You are missing a part or the Sterilox Dental Generator is broken The unit fails to power on which means that none of the lights are illuminated on the Reservoir Status Panel You are out of Sterilox Electrolyte Solution The Sterilox Solution or the Waste Product has spilled in the well s When starting with an empty waste container the waste container overflows with waste product on a single 500 ml dispense The Sterilox Solution has a very strong chlorine odor The Sterilox Generator fails to operate Sterilox Dental Solution Call PuriCore Customer Service Check the fuses If the fuses are okay call PuriCore Customer Service Call PuriCore Customer Service to order additional Sterilox El
16. posal in drains Sterilox Dental Generator Controls The Reservoir Status Panel displays two lights to indicate the level in the Electrolyte reservoir The green OK light indicates that the unit is ready to be used The yellow LOW light indicates that the reservoir requires one bottle of Sterilox Electrolyte Solution Flashing lights indicate that an error has occurred Depress and continue to hold down the gray Dispense Button to generate Sterilox Solution Release the Dispense Button to stop the generation of Sterilox Reservoir Status OK Reservoir Solution Each time the panel is depress a minimum of 250 ml must be produced to keep the Sterilox Solution within specification The Power Switch allows you to turn the Generator on or off The Generator can be left On when not in use Power switch 800 604 1879 Press the Dispense Panel to generate Sterilox Solution Sterilox Dental Installation and Priming Caution Read all warning and safety instructions before operating the Sterilox Dental Generator 1 Unpack the Sterilox Dental Generator Discard any packing material including any REMOVE BEFORE USE labels and underlying packaging material Do not apply power to the Sterilox Dental Generator until all packing materials are removed Remove any rubber caps covering the spouts on the dispense well top and the waste well bottom 2 Replace the Uptake Tubes IMPORTANT The uptake tubes inside th
17. presentative Sterilox Dental 800 604 1879 Prime the Generator 4 Fill the Generator with Sterilox Electrolyte Solution Lift the fill lid on the top of the Sterilox Dental Generator Carefully and slowly pour an entire bottle of the Sterilox Electrolyte Solution into the funnel The green OK light on the Reservoir Status Panel will illuminate Use caution when pouring the Sterilox Electrolyte Solution to avoid spills The priming process conditions the Sterilox Dental Fill the Generator with Sterilox Generator for use and is only needed when it is first unboxed or unused for an extended period Hold down the Dispense Button and dispense 200 ml of Sterilox Solution into the dispense container Electrolyte Solution This initial portion of the Sterilox Solution primes the Generator s electrochemical cell is not suitable for use and should be discarded down a sink drain Dispose of the waste product in the waste container as well Replace both the dispense container and waste o Press the Dispense Button to container into their respective wells Wait 10 minutes generate Sterilox Solution for before using the Sterilox Dental Generator again priming Note During the initial priming process the Generator might become unresponsive as the unit initiates itself Turn the power off and then on to reset the Generator Repeat the priming procedure two to three times until the Generator no longer becomes unresponsive
18. t allow the waste product to be inhaled or ingested Wash your hands after handling Sterilox Solution might cause slight discoloration of some unprotected metals such as aluminum and steel After being thoroughly wetted with Sterilox Solution for 5 minutes wipe dry with a paper towel sponge or cloth Use the Sterilox Dental Generator only as described in this user manual and only with the accessories supplied or recommended by PuriCore Use only the approved Sterilox Electrolyte Solution Use of any other solution can severely damage the Sterilox Dental Generator and will void the warranty Never operate the Sterilox Dental Generator unless both the dispense container and the waste container are inserted into the wells of the Generator Always use the Sterilox Dental Generator on a firm level surface to ensure against tipping Do not move the unit when it is filled with fluid unless the Generator is malfunctioning and must be drained Operate the Generator in an upright position Placing unit on its side or on its back or front risks spilling of the Sterilox Electrolyte Solution and other damage 800 604 1879 Sterilox Dental
19. tion 8 Attach the bottle and run a minimum of 250 ml of Sterilox Solution through each of the individual water lines 9 Air purge the unit water lines until the Sterilox Solution is removed 10 Fill the dental unit water bottle with diluted Sterilox Solution for Daily Maintenance see table below and flush each line with a minimum of 200 ml Daily Maintenance of Dental Unit Water Lines Use diluted Sterilox Solution for Daily Maintenance every time you refill your dental until water bottle to keep the water lines free of biofilms buildup Fill the water bottle with a small volume of Sterilox Solution diluted with water based on the bottle capacity according to the table below Water Bottle Capacity Add Water to Bottle Add Sterilox Solution 800 604 1879 Sterilox Dental Warnings Always unplug the power cord from the back of the Sterilox Dental Generator before initiating any maintenance procedures to avoid shock or damage to unit Never allow fluid to enter the power entry connection Never place a filled Sterilox Dental Generator on its side or upside down Cleaning the Sterilox Dental Generator s Exterior e Always clean the exterior of the Sterilox Dental Generator in its upright position e Keep the funnel lid closed while cleaning Seepage of cleaning solution into the funnel will contaminate the solution in the reservoir tank e Remove the dispense and waste containers from the wells of the Sterilox Dental Generator
20. voir tank until thoroughly wetted Allow the surface to remain wet for 5 minutes e Overfilling the Sterilox Electrolyte Solution can damage the electric components of the Sterilox Dental Generator and will void the warranty Never top off overfill the tank or add Sterilox Electrolyte Solution while the green OK light is illuminated Wipe the surface with a clean cloth sponge or paper towel Endodontic Cleanser Sterilox Solution is intended for use as an endodontic cleanser following root canal procedures Dispense Sterilox Solution using a disposable standard dental syringe The mechanical action of the Sterilox Solution moving in the root canal facilities easy removal e Never pour the Sterilox Solution or the Waste Product back into the Generator of debris and necrotic pulp tissue from the root canal Use Sterilox Solution to irrigate cleanse moisten lubricate and debride root canal systems e Sterilox Electrolyte Solution is not a disinfectant or endodontic cleansing solution 1 Fill 12 cc of Sterilox Solution into the recommended standard dental syringe either two 6 cc syringes or one 12 cc syringe and attached a standard endodontic needle approximately 27 30 gauge to the syringe 2 Remove the cap from the needle and insert the needle into the root canal NOTE As with any endodontic procedures use a rubber dam for endodontic therapy and prevent ingestion of the Sterilox Solution Use personal and patient protection to