4Z Input/2 Output Expansion SnapCard Installation

image

Contents

1. WIRI NG TERMINALS Caution To prevent damage to the panel or card always remove panel AC power and disconnect the backup battery before installation 1 Remove panel AC power and disconnect backup battery Caution You must be free of static electricity when handling electronic components Touch a bare metal surface before touching the circuit board 2 Align the card holes with the standoffs and connector pins as shown in Figure 2 3 or 4 3 Press firmly to secure the board to the connector 4 Secure the card with the two thread rolling mounting Screws Figure 2 Installing the card in a Concord panel CONTROL PANEL pj BOARD e OPTIONAL EXPANSION lie CONNECTOR I H ALIGN BOARD el HOLES WITH STANDOFFS O q O w to Danie E 7 OPTIONAL expansion carp Figure 3 Installing the card Concord Express panel Hp PUSH SNAPCARD CONNECTOR ONTO PANEL HEADER SECURE SNAPCARD WITH TWO SCREWS 8642G31A DSF Figure 4 Installing the card in an Advent panel SECONDARY EXPANSION CARD connector gt PRIMARY EXPANSION CARD CONNECTOR CONTROL PANEL Ca C c CIRCUIT BOARD t 4 _____0 ___ ALIGN BOARD HOLES WITH STANDOFFS O EXPANSION CARD B 2 e
2. and rate of rise heat sensors 14 12V Out Auxiliary output regulated DC power supply 12 VDC 9 0 5A maximum Note If this output is used it will draw up to 500 mA from the panel Remember to include this current draw when calculating total panel power To wire the card all panels 1 Disconnect panel AC power and backup battery 4Z Input 2 Output Expansion SnapCard Installation Instructions 2 Wire the input devices or smoke detectors as shown in Figure 5 Use terminals 11 and 12 for the two wire 12V smoke detector loop You can connect up to 10 twowire smoke detectors on the loop for Concord and Concord Express panels Advent panels allow up to 20 twowire smoke detectors Use end of line resistors on all hardwire input loops as shown e Use Table 2 for two wire smoke detector loop and zone input wire lengths Important For Advent UL 864 listed applications all inputs and outputs must be dedicated to either fire or burglary applications Do not mix fire and burglary on any SnapCard in any partition for these installations 3 Reconnect the backup battery s and restore panel AC power Table 2 Maximum wire lengths Two wire Smoke Detector Loop Zone Input Wire Run Lengths Lengths Gauge Max Distance feet 22 330 300 20 470 18 830 750 16 1200 14 1900 12 2900 10 ohms maximum wire resistance Wire run based on 10 ohms maximum wire and device resistance including 2 0k ohm EOL resis
3. does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the affected equipment and the panel receiver to separate outlets on different branch circuits Consult the dealer or an experienced radio TV technician for help Contact information For contact information see www utcfireandsecurity com or www interlogix com For technical support toll free 888 437 3287 in the US including Alaska Hawaii Puerto Rico and Canada Outside the tool free area contact your dealer Copyright 2011 Interlogix a UTC Fire amp Security Company All rights reserved 4Z Input 2 Output Expansion SnapCard Installation Instructions
4. State Fire Marshall FCC compliance FCC Part 15 Information to the User Changes or modifications not expressly approved by Interlogix can void the user s authority to operate the equipment FCC Part 15 Class A This equipment has been tested and found to comply with the limits for a class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment
5. ing and connections Check that the output programmed trigger event actually occurs An output relay may have failed or been overloaded Reprogram to use a different unused output or replace the card Wrong output activates Check panel output programming Check output device wiring and connections Specifications Compatibility Concord Concord Express and Advent panels Power requirements 12 VDC 185 mA maximum from panel and panel backup battery Storage temperature 30 to 140 F 34 to 60 C Operating temperature 32 to 140 F 0 to 60 C Maximum humidity 90 relative humidity noncondensing Inputs Three supervised UL Fire rated hardwire zones One 12V Class B style B two wire smoke detector loop that provides up to 100 mA 10 detectors on Concord panels 20 detectors on Advent panels Outputs Two Form C relay contacts Contacts rated 5 0A 30 VDC maximum each contact or 5 0A 70 VAC One 12 VDC 500 mA regulated power output from the panel Power limited to 6 watts Dimensions 2 0 x 5 25 x 0 75 Hx W x D Installation In panel mounting Regulatory information Manufacturer UTC Fire amp Security Americas Corporation Inc 1275 Red Fox Rd Arden Hills MN 55112 6943 USA UL listings UL 985 Household Fire Warning System Units UL 1023 Household Burglar Alarm System Units UL 1610 Central Station Burglar Alarm Units Commercial Burglary CSFM California
6. interlogix A UTC Fire amp Security Company 4Z Input 2 Output Expansion SnapCard Installation Instructions Product summary 4Z Input 2 Output Expansion SnapCard The 4Z Input 2 Output Expansion SnapCard combines the capabilities of the 8Z Input and 4 Output Expansion SnapCards The card expands Concord Concord Express and Advent Panels The card includes the following features One 12V Class B two wire smoke detector loop that provides up to 100 mA Concord and Concord Express panels support up to 10 smoke detectors while Advent panels support up to 20 Compatible smoke detectors include System Sensor Models 21008 2100TS 2100D 2100TD 2400 2400TH Sentrol ESL Models 429AT 521B 521BXT Two Form C contact relays The relays are controlled by System commands or a combination of states and system events Three supervised UL Fire rated hardwire loops 2k ohm end of line resistors required that can be used for any UL listed hardwire device including Four wire smoke detectors Fire pull stations Water flow detector switches P N 466 1367 REV D January 2011 Gate valve switches Control valve supervisory switches Butterfly valve switches Rate of rise detectors Carbon monoxide and other gas detectors and e Standard burglar detection devices On Advent panels this card may be installed into the primary or secondary expansion slot and in combination w
7. ith other cards Outputs may be programmed to turn on lights open drapes and garage doors turn on a closed circuit TV CCTV camera during a burglary alarm turn exit lighting on during fire alarms and activate backup cellular phones or long range radios if primary communications are inoperable Installation guidelines Install a 2k ohm end of line resistor at the end device on each supervised two wire hardwire loop Install a power supervision module at the end device on four wire smoke loops e Plug the expansion card into the Concord panel expansion card connector the Concord Express expansion card connector or either the primary or secondary expansion card connector of the Advent panel Important On Advent panels SnapCard expansion slots must be used for either fire or burglary applications Do not mix fire and burglary applications on SnapCard inputs and outputs Use 4 conductor 22 gauge or larger wire from the terminals to the devices Use 18 gauge or larger for all fire applications Tools needed Screwdrivers e 22 gauge or larger hookup wire Thread rolling mounting screws included 2k ohm end of line resistors included Installation Use the following instructions to install the card wire input devices and program the panel Figure 1 Card components 4Z INPUT 2 OUTPUT EXPANSION SNAPCARD MOUNT ING PANEL SCREW RELAYS 2 CONNECTOR HOLES 2
8. l 42 Input 2 Output Expansion SnapCard Installation Instructions Wiring Table 1 describes each SnapCard terminal Terminals are numbered left to right Figure 5 shows how to wire detection loops and devices to the card Note Terminal 11 SMK can also power 4 wire smoke detectors Table 1 Card wiring terminal descriptions Terminal Description Use number 1 Relay 1 NC Normally closed N C opens on activation output 1 dry relay contact connection 2 Relay 1 Common C side of output 1 dry relay COM N C and N O contacts terminals 1 and 3 Contacts rated 5 0A 30 VDC or 5 0A 70 VAC maximum 3 Relay 1 NO Normally open N O closes on activation output 1 dry relay contact connection 4 Relay 2 NC Normally closed N C opens on activation output 2 dry relay contact connection 5 Relay 2 Common C side of output 2 dry relay COM N C and N O contacts terminals 2 and 6 5 0A 30 VDC or 5 0A 70 VAC maximum 6 Relay 2 NO Normally open N O closes activation output 2 dry relay contact connection 7 ZN1 Hardwire Input zone 1 8 ZCOM Common for hardwire input zones 1 2 and 3 9 ZN2 Hardwire Input zone 2 10 ZNS3 Hardwire Input zone 3 11 SMK Smoke sensor power supply Switched 12 VDC 100 mA maximum Positive side of 2 wire 12 VDC smoke loop 12 SMK Negative side of 2 wire 12 VDC smoke loop 13 GND Ground for 4 wire smoke sensors
9. problem occurs Refer to the panel nstallation Instructions and User s Manual for sensor zone or output testing information Note While the sensor test is a valuable installation and service tool it only tests sensor operation for the current conditions You should perform a sensor test after any change in environment equipment or programming Troubleshooting all panels Use Tables 3 and 4 to help diagnose and fix problems Table 3 Troubleshooting Hardwire Inputs Problem Action Solution One wrong or no inputs are detected Check input device wiring and connections Check panel input programming Check that the 2k ohm end of line resistor is correctly installed in the zone loop circuit Sensor trouble is indicated Check normally open N O input circuit for a break in the wires Check normally closed N C input circuit for a short in the wires Check input circuit for wires shorted to ground Check that ZCOM terminal 8 is used for input zone common and not GND terminal 13 Table 4 Troubleshooting Hardwire Outputs Problem Action Solution No outputs activate Check panel card programming Check output wiring and connections Check panel card power supplies If used check the optional external supply powering the output devices 4Z Input 2 Output Expansion SnapCard Installation Instructions One output never activates Check panel card programming for that output Check output wir
10. tor Figure 5 Typical 4Z Input 2 Output SnapCard Wiring 4Z Input 2 Output EXPANSION CARD TERMINALS RELAY 1 RELAY 2 SMOKE N C COM COM ZN1 ZCOM ZN2 ZN3 GND 12VOUT gt gt gt 4 5 4 OUTPUT EVICE CONTROL N O LISTED 2 WIRE or 4 WIRE 12V 12V SMOKE HEAT LISTED HARDWIRE DETECTOR SMOKE HEAT SUCH AS DETECTOR SUCH ESL 429AT AS ESL 449AT NJ prd NORMALLY USE IN AND OUT USE IN AND OUT DAISY CHAIN NIC N O DAISY CHAIN WIRING popa CONTACTS WIRING METHODS METHODS ONLY IN PARALLEL ONLY 2 0k Ohm EOL RESISTOR N RED 49 467 BLACK INSTALL AT LAST DEVICE GREEN WHITE 2 0k Ohm EOL RESISTOR fe 49 467 INSTALL AT LAST DEVICE POWER SUPERVISON UNIT SUCH AS ESL 204 12 24V x INSTALL AT LAST DEVICE TO ANY ZONE INPUT 4 4Z Input 2 Output Expansion SnapCard Installation Instructions Programming Input and output zones must be programmed to communicate with the panel and to function as desired For zone programming information refer to the panel nstallation Instructions Testing Once installed the card becomes an integral part of the panel We recommend that you test all zone inputs and outputs after all programming is completed and whenever a sensor or output related