1. Save a tree please don t print this document unless you really need to ORVOS monitooring GSM Alarm and Control system Gsm Eco v 1 0 info orvos ee Www orvos ee Content 1 General information 1 1 Function 1 2 Operation Description 1 3 Technical Specifications 1 4 Connector and LED Indicators Functionality 1 5 Connection Circuit 1 6 System Installation 2 System control commands 2 1 Change the way system informs about events 2 2 Enabling disabling zones 2 3 Managing Output Controller 3 Appendix 3 1 Technical support er OOOO DADA AAaAN oo info orvos ee Www orvos ee User Manual v1 0 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around e Gsm Eco later referenced as system contains a radio transceiver operating in 850 900 1800 1900 MHz bands Don t use the system in hazardous environment Don t use the system where it can interfere with other devices and cause any potential danger Don t use the system with medical devices e Don t use the system in hazardous environment e Don t expose the system to high humidity chemical environment or mechanical impacts Don t attempt to personally repair the system Any system repairs must be done only by qualified safety aware personnel The system must be powered by external DC 15VA power supply which must be approved by LST EN 60950 1 standard Any a
2. collector controlled output It can be used to control various electrical devices such as electric pumps heating lighting etc When outputs are enabled it corresponds to output pins being pulled to ground GND Enabling output OUT ON Disabling output OUT OFF info orvos ee Www orvos ee 3 Appendix 3 1 Technical Support Indication Possible reason Indicator is off or not blinking no external power supply circuit not properly connected blown fuse no network signal Indicator blinking several times per second SIM card is not inserted PIN code hasn t been disabled SIM card is not active System does not send any SMS messages and or does not ring SIM card account depleted incorrect SIM central number no network signal user number is not programmed If your problem could not be fixed by the self guide above please contact your distributor or tech support by email info orvos ee More up to date information about your device and other products can be found at the website www orvos ee 10
3. dditional device connected to the Gsm Eco system must be powered up by a LST EN 60950 1 approved supply External power supply can be connected to AC mains only inside installation room with automatic 2 pole circuit breaker capable of disconnecting circuit in the event of short circuit or over current condition Open circuit breaker must have a gap between connections of more than 3mm Mains power must be disconnected before any installation or tuning work starts The system installation or maintenance must not be done during stormy conditions Fuse F1 type C1S 2 5A Blown fuse cannot be replaced by the user and the replacement fuses have to be exactly the same as indicated by the manufacturer The WEEE Waste Electrical and Electronic Equipment marking on this product or its documentation indicates that in the EU the product must not be disposed of together with household waste info orvos ee Www orvos ee Limited Liability The buyer must agree that the system will reduce the risk of fire theft burglary or other dangers but does not guarantee against such events Orvos Monitooring LTD will not take any responsibility regarding personal property or revenue loss while using the system Orvos Monitooring LTD responsibility according to local laws does not exceed value of the purchased system Orvos Monitooring LTD is not affiliated with GSM operators providing cellular services therefore is not responsible for the
4. le call forwarding and voice mail It is worth to choose the same GSM cellular provider as most users use assuring fast and reliable SMS message delivery and phone call connection Even though alarm system Gsm Eco installation is not complicated it is recommended to be performed by a person with basic knowledge in electrical engineering and electronics to avoid any system damage info orvos ee Www orvos ee 2 System control commands S Very important Underscore symbol _ in this manual is used to represent space When writing SMS messages every underscore symbol should be replaced by single space symbol Don t leave any space at the beginning and the end of the message 2 1 Change the way system informs about events By default the system is set to inform users about events via SMS message To set system to inform users via calls user have to send SMS message to Gsm Eco CALL To change back the system to inform users via SMS user have to send SMS message to Gsm Eco SMS 2 2 Enabling disabling zones Enabling Zone Any zone can be enabled by sending the following SMS message ZONE1 ON or ZONE2 0N Disabling Zone Any zone can be disabled by sending the following SMS message ZONE1 OFF or ZONE2 OFF The zones can be enabled disabled together or separately one by one Both zones can be disabled by sending the following SMS message ZONE1 OFF_ZONE2 OFF 2 3 Managing Output Controller Alarm system Gsm Eco has open
5. n 2 Allowable digital input voltage values 0 30V Impulse duration gt 600ms Number of outputs 1 Output max parameters Current 500mA voltage 30V Output circuit OUT Open collector output Output is i pulled to COM when enabled L L Dimensions 108x52x30mm Operating temperature range 20 550C 1 4 Connector Functionality Short explanation of the main units Picture 1 GSM MODEM GSM network 850 900 1800 1900 MHz modem SIM CARD SIM card LED Light emitting diodes indicator ANT GSM antenna Connector functionality info orvos ee Www orvos ee Labeling Explanation DC DC power in connector COM Earth pin OUT Controlled output Open collector Zl Digital input Z1 Z2 Digital input Z2 1 5 Connection Circuit Useful Information When choosing GSM cellular provider it is worth inquiring whether the service is used in security application assuring fast and reliable SMS message delivery and phone call connection System Gsm Eco and security unit COM must be connected Inputs Z1 and Z2 are connected to security unit PGM outputs if PGM are implemented as open collector circuit or any other circuit and if it commutates with COM It is also possible to connect Z1 and Z2 inputs to for instance motion sensor or any other sensor as well as automatics device provided the inputs are comm
6. quality of cellular services Warranty Warranty period is a 24 month Warranty period starts from the day the system has been purchased by the end user The warranty is valid only if the system has been used as intended following all guidelines listed in the manual and within specified operating conditions Receipt with purchase date must be kept as a proof The warranty is voided if the system has been exposed to mechanical impacts chemicals high humidity fluids corrosive and hazardous environment or other force majeure factors Package content 1 GSM EGO irsin eerie qty 1 About User Manual This document describes Gsm Eco its operation and installation It is very important to read User Manual before start using the system info orvos ee Www orvos ee 1 General Information 1 1 Function Gsm Eco is a microcontroller based device used to inform users about the alarm in automatic or security systems and control one electric appliance open collector 1 2 Operation Description Alarm and control system Gsm Eco works over GSM network It works 24 7 i e it always reacts to the incoming signal The system has two digital inputs normal open When the alarm siren motion sensor fire alarm sensor door sensor any other sensor or PGM output gets activated Gsm Eco system sends an SMS messages or calls to both User1 and User2 numbers Userl and User2 numbers must be entered into SIM card memory Only one user can be u
7. sed as well Any number format can be used for example 37211111111 11111111 or even short numbers like 111 Users can choose which way the system informs about triggered zones By default SMS mode is enabled and SMS message with the name of the triggered input zone is being sent to both users for example Triggered ZONE or Triggered ZONE2 When triggered zone is restored the system sends SMS about restored zone and turns back to the previous status for example Restored ZONE1 or Restored ZONE2 If system calling mode is enabled at first the system will call to Userl and then to User2 If user answers to the system call it will last for 10 seconds and then system will hang up Gsm Eco can control electronic appliance an open collector from a GSM phone of any of the users For example users can turn on or off the heating lighting lift the gates blinds etc The system remembers the status of output in case of temporary electricity failures The system will ignore requests and calls coming from unknown telephone numbers If user calls to the Gsm Eco it will answer the call This function is useful to check if the system is working correctly info orvos ee Www orvos ee 1 3 Technical Specifications Electrical and mechanical specifications Supply voltage 9 15V 300mA DC max Current used in standby mode 30mA max GSM modem frequency 850 900 1800 1900 Mhz Number of digital inputs normal ope
8. utated with COM Gsm Eco aa DC COM OUT PR PRG OAE K Bg gt gt av Alarm system or other appliance Picture 2 info orvos ee Www orvos ee DC power supply connection circuit Alarm system or other Gsm Eco appliance Picture 3 1 6 System installation The system box should be fixed with four screws to the wall Since the Gsm Eco has integrated GSM antenna it should not be installed into the metal box For the connection of power supply output and inputs connectors should be used 1 thread 0 5mm2 cable Cables should be connected to the connectors and brought through the special cover hole for cables 1 Place SIM card in the holder but make sure that SIM card PIN code request is disabled PIN code can be disabled by putting SIM card into mobile phone and following proper menus SIM card should not have any remaining SMS messages 2 Connect the circuit as shown in Picture 2 Power supply cables are connected last When connecting Gsm Eco to security central system power supply usually the security system AUX output is used 3 When DC power supply ground transformer is used connect according to Picture 3 there is no need to connect any other power supplies 4 The system will start in less than a minute To increase system reliability it is recommended not to use prepaid SIM cards The system would fail to send any messages upon depletion of prepaid account Also it is recommended to disab