2.    PRO1D V11 122 series MID    DIN rail single phase two wire energy meter       User manual    Version 1 0    DMMetering g 2011    1 1    1 2    1 3    1 4    1 5    1 6    1 7    1 8    Safety instructions  Foreword   MID certificates  Type number table  Performance criteria  Specifications  Basic errors  Description  Dimensions  Installation  Operation  Troubleshooting    Technical support       User manual 0014       1 1 Safety instructions    A  A    Information for Your Own Safety   This manual does not contain all of the safety measures for operation of this  equipment  module  device  because special operating conditions  local code  requirements or local regulations may necessitate further measures  However  it  does contain information which must be adhered to for your own personal safety and  to avoid damage to the equipment  This information is highlighted by a warning  triangle with an exclamation mark or a lightning bolt depending on the severity of  the warning     Warning  Means that failure to observe the instruction can result in death  serious injury or  considerable material damage     Caution  Means hazard of electric shock and failure to take the necessary safety precautions  will result in death  serious injury or considerable material damage     Qualified personnel   Installation and operation of this equipment described in this manual may only be  performed by qualified personnel    Only people that have proper knowledge about the local standards rega
3.   The warranty period is 3 years after production  and only valid for construction  faults     DMMeteringg 2011 sox User manual 0014       1 3 MID certificates    KEMAX       CERTIFICATE    EC Type examination certificate 6319 10    Manufacturer   Inepro Metering BV  Contact person   D  van der Vaart  Address   P O  Box 92  Postal code  Place   2450 AB  Leimuiden  Country   The Netherlands  Instrument   Electronic single phase two wire energy meter  Direct connected  Mark   Type   PRO 1TE PRO1D  Register   Mechanical LCD  Accuracy Class    B  Measurement range   230V  5 45  A  50 Hz  2000 imp  kWh  Temperature range  gt   10  40   C  Use   Indoor  Protection Class an    Environmental class   M1  E2  Registry method   bidirectional method with always positive register  the meter always counts the energy    of the measuring point as received energy  irrespective of the real energy direction    The energy meter meets the requirements of Directive 2004 22 EC of the European parliament and the council of  31 March 2004 on measuring instruments     Certification was based on compliance with the following harmonised standards     EN 50470 1  2006    Electricity metering equipment  a c   part 1  General requirements  tests and test  conditions   Metering equipment  class indexes A  B and C   EN 50470 3  2006    Electricity metering equipment  a c   part 3  Particular requirements   Static meters for    active energy  class indexes A  B and C   Valid until   March 30  2020  The result
4.  meter should be installed on a location where the meter can be read  easily      When the meter is installed in an area with frequent surges for example due  to thunderstorms  welding machines  inverters etc  the meter should be  protected with a Surge Protection Device      After finishing installation  the meter can be sealed to prevent tampering      Connection of the wires should be done in accordance with the following  connection diagram     DMMeteringg 2011 28 User manual 0014                1 phase line in   3 phase line out   4 neutral line in   6 neutral line out   20 and 21 Pulse output contact    1 11 Operation    Consumption indication   There is a two color LED on the front panel of the meter  When the meter is powered  on and no load is connected to it  the LED lights up green  When power is consumed   the LED will flash red  The faster the LED flashes  the more power is consumed  For  this meter  the LED will flash 1000 or 2000 times per kWh depending on the version  of the meter  see section 1 3 for details    Please note  There are two versions of this meter with a difference in how reverse  current is handled  One version counts up in both directions and one only counts up  in one direction and doesn   t count in the other direction    This has an effect if the meter is connected in reverse  terminal 3 Load in and  terminal 1 load out  or used with any sort of energy production system  solar panels   wind generators  etc   See section 1 3 for details     R
5.  registered trademark of Inepro Metering   member of the  Inepro Group  Other names appearing in this manual may be trademarks of  third parties and are property of their respectful owners     1 2 Foreword    Thank you for purchasing the DMMetering PRO1 series DIN rail single phase two  wire energy meter  The DMMetering PRO1 series energy meter is the most  advanced type electronic kWh meter available at the market  With the  DMMetering product range we have introduced a large scale of energy meters on  the market suitable for 110V AC to 400V AC  50 or 60Hz   Besides the normal  energy meters we also developed our own pre paid energy and water meters  with chip card or infrared card and a complete PC management control system   For more information on other products please contact our sales department at  Sales ineprometering com or info inepro com hk     Although we produce the DMMetering PRO1 series meter according to the  requirements of IEC 62053 3 and our quality inspection is very accurate there  might always be a possibility that your product shows a defect or failure for  which we do apologize  Under normal conditions your product should give you  years of trouble free operation  In case there is a problem with the energy meter  you should contact your dealer immediately  All energy meters are sealed with a  special seal  Once this seal is broken there is no possibility to claim any warranty   Therefore NEVER open an energy meter or break the seal of the energy meter 
6. RO1 series is labeled as follows     PRO1D TE V11 xxx    L__   Pulse led and pulse output   1   1000 impulses   kWh  2   2000 impulses   kWh  Reverse counting   1   Does not count when energy is reversed  2   Counts up regardless of energy direction    Type of display     1   LCD without backlight PRO1D  2   LCD with backlight PRO1D  3   Mechanical register PRO1ITE    1 5 Performance criteria     Operating humidity   Storage humidity   Operating temperature  Storage temperature  International standard  Accuracy class   Protection against penetration  of dust and water   Insulating encased meter  protective class    1 6 Specifications     Meter type   Nominal voltage  Un   Operational voltage   Insulation capabilities      AC voltage withstand     Impulse voltage withstand   Basic current  Ib    Maximum rated current  Imax   Max  current for direct wire connection  Max  current for busbar connection  Operational current range   Peak current withstand  Operational frequency range  Internal power consumption   Test output flash rate  RED LED   Pulse output rate  pins 20  amp  21   Consumption indicator  RED LED     75    95     10  C    50  C   30  C    70  C  EN 50470 3   1     lt    lt     IP51    II    PRO1 series  230V AC  161   300V AC    2KV for 1 minute   6KV   1 2uS waveform   5A   45A   32A   45A   0 4  Ib  Imax   30Imax for 0 01s   50Hz  10     lt 2W   10VA   1000 or 2000 imp kWh  see section 1 3  1000 or 2000 imp kWh  see section 1 3  Flashing at load running    User 
7. e injury    e Make sure the protection cover is placed after installation    e Installation  maintenance and repair should only be done by qualified   personnel     DMMeteringg 2011 22x User manual 0014       e Never break the seals to open the front cover as this might influence the  functionality or accuracy of the meter  and will void all warranty    e Do not drop  or allow physical impact to the meter as there are high precision  components inside that may break and render the meter measurement  inaccurate     Exclusion of liability   We have checked the contents of this publication and every effort has been  made to ensure that the descriptions are as accurate as possible    However  deviations from the description cannot be completely ruled out  so  that no liability can be accepted for any errors or omissions in the information  given  The data in this manual is checked regularly and the necessary  corrections will be included in subsequent editions  If you have any suggestions   please let us know     Subject to technical modifications without notice     Copyright   Copyright Inepro Metering March 2011 All rights Reserved    It is prohibited to pass on or copy this document or to use or disclose its contents  without our express permission  Any duplication is a violation of the law and  Subject to criminal and civil penalties  All rights reserved  particularly for  pending or approved patents award or registered trademarks     Registered trademarks   DMMetering   is a
8. eading the meter  The PRO1 series meter can be delivered with either a digital or mechanical register   See the version numbering in section 1 3     Digital register   The PRO1D series energy meter is equipped with a 5 2 digit LCD which is used  to record consumption and can t be reset to zero  The display has 5 digits before  and 2 decimals after the dot on the display  The reading accuracy is 1 100 kWh     Mechanical register  The PROTE series energy meter is equipped with a mechanical 5 1 register  which is used to record consumption and can   t be reset to zero  Five decimals  are marked with black color and one decimal is marked with red  The reading  accuracy is 1 10 kWh     Pulse output   The PRO1 series DIN rail energy meter is equipped with a pulse output which is  optically isolated from the inside circuit  It generates pulses in proportion to the  measured consumption for purpose of remote reading or accuracy testing  The  pulse output is a polarity dependant  open collector transistor output requiring an  external voltage source for correct operation  For this external voltage source  the  voltage  Ui  should be lower than 27V DC  and the maximum switching current   Timax  is 27MA  To connect the impulse output  connect 5 27V DC to connector 20   collector   and the signal wire  S  to connector 21  emitter   The pulse output  depends on the version and is either 1000 or 2000 impulses per kWh  See section  1 3 for details regarding the impulses per kWh     DMMeteri
9. it breaker or other  overcurrent protection device used in the circuit      An external switch or a circuit breaker should be installed on the supply  wires  which will be used to disconnect the meter  It is recommended that  this switch or circuit breaker is placed near the meter because that is more  convenient for the operator  The switch or circuit breaker should comply  with the specifications of the building   s electrical design and all local  regulations      An external fuse or thermal cut off which will be used as an overcurrent  protection device for the meter must be installed on the supply side wire  and  it is recommended that this protection device is near the meter since that is  convenient for the operator  The overcurrent protection device should  comply with the specifications of the building   s electrical design and all local  regulations      This meter can be installed indoor  or outdoor enclosed in a meter box which  is sufficiently protected  subject to local codes and regulations      TO prevent tampering  an enclosure with a lock or a similar device can be  used      The meter has to be installed against a fire resistant wall      The meter has to be installed in a well ventilated and dry place      The meter has to be installed in a protective box if the meter is exposed to  dust or other contaminants      The meter can be installed and used after being tested and can be sealed  afterwards      The meter can be installed on a 35mm DIN rail      The
10. manual 0014       1 7 Basic errors     0 05Ib   O 1Ib   O 1Ib   Imax  O 2Ib   Imax    1 8 Description    m    OOW DY    Material    Register   Case   Terminal block  Protection cover       1 9 Dimensions    Height  Width  Depth  Weight    DMMetering g 2011       Cos  m   1  1 5   Cos     0 5L  1 5   Cos     0 8C  1 5   Coso   1  1 0   Cos     0 5L  1 0   Cos     0 8C  1 0   Register   Terminal block   Case    Protection cover  Security wire slot    PC inflammable plastic   ABS inflammable plastic  ABS inflammable plastic  ABS inflammable plastic       C B  18  A  i  wo  T    35    91  117 5  D E  117 5 mm  18 mm  58 5 mm  0 12 Kg  net    7  User manual 0014    Turn off and if possible lock all sources supplying the energy meter and the  equipment that is connected to it before working on it    Always use a properly rated voltage sensing device to confirm that power is  off     Installation should be performed by qualified personnel familiar with  applicable codes and regulations    Use isolated tools to install the meter    Fuse or thermal cut off or single pole circuit breaker should be fitted on the  Supply line and not the neutral line    The meter   s casing is sealed  if not properly looked after  this seal could be  broken  voiding the warranty and damaging the meter          We recommend that the connecting wire which is used to connect meter to  the outside circuit should be sized according to local codes and regulations  for the maximum amount of current of the circu
11. ng wires to the  connected in meter  clamp 3 should be  reverse in case of a   connected to load in and clamp 6  reverse enabled to load out    meter   See section 1 10 for details     Maybe there is a Please contact technical support  fault inside the for a meter replacement   meter     The register doesn   t   Is there almost no   Check if the consumption led is  count  load on the meter    blinking  see above   200 flashes  of the LED equals 0 1kWh or  O 2kWh and should be clearly  visible on the display     Maybe there is a Please contact technical support  fault inside the for a meter replacement   meter     No pulse output  Is DC power Check the external voltage source  connected to the  Ui  is 5 27V DC   meter      Is the pulse output   Check correct connection   connected connect 5 27V DC to connection  correctly  20  collector   and the signal wire   S  to connection 21 emitter      Maybe there is a Please contact technical support  fault inside the for a meter replacement   meter   Pulse output rate Maybe there is a Please contact technical support  wrong  fault inside the for a meter replacement     meter        DMMeteringg 2011   11    User manual 0014       1 13 Technical support  For questions about one of our products please contact     The Inepro Metering dealer in your region      Your local Inepro Metering distributor    Email  support ineprometering com    www ineprometering com    5        RoHS  2002 95 EC    Hy    DMMeteringg 2011  12  User manual 0014   
12. ngg 2011  O User manual 0014    DMMeteringg  2011    During repair and maintenance  do not touch the meter connecting clamps  directly with your bare hands  with metal  blank wire or other conducting  material as that will cause an electric shock and possibly cause injury   Turn off and if possible lock all sources supplying the energy meter and the    equipment that is connected to it before opening the protection cover  before working on it    Turn off and lock out all power supply to the energy meter and the  equipment to which it is installed before opening the protection cover to  prevent the hazard of electric shock     Maintenance or repair should only be performed by qualified personnel  familiar with applicable codes and regulations    Use insulated tools to maintain or repair the meter    Make sure the protection cover is in place after maintenance or repair   The meter   s casing is sealed  if not properly looked after  this seal could be  broken  voiding the warranty and damaging the meter         10  User manual 0014       Problem check  Solution    The consumption Is there any load Only if there is a load on the meter  LED is not flashing   connected to the will this LED flash     PULSE LED   meter    If the load is very low  the time  Is the load on the between 2 flashes is very long   line very low  This can be mistaken for a broken  meter  As a test  an electric water  boiler   1L600W  should make it  blink once every second     Is the meter Swap the connecti
13. rding  electrical installations and are allowed to work on these installations according to  the local regulations are considered qualified personnel in this manual     Use for the intended purpose   The equipment  device  module  may only be used for the application cases  specified in the catalog and the user manual and only in connection with devices  and components recommended and approved by Inepro Metering B V     Proper handling   The prerequisites for perfect  reliable operation of the product are proper transport   storage  installation and connection  as well as proper operation and maintenance   When operating electrical equipment  certain parts of this equipment carry  dangerous voltages  Improper handling can therefore result in serious injury or  material damage     Only use isolated tools suitable for the voltages the meter is used for    Do not connect while the circuit is energized  current is running     Do not connect the meter to a 3 phase   400VAC   network    Place the meter only in dry surroundings    Do not mount the meter in an explosive area or exposed to dust  mildew   and or insects    Make sure the used wires are suitable for the maximum current of this meter    e Make sure the AC wires are connected correctly before activating the  current voltage to the meter    e Do not touch the meter   s connection clamps directly with your bare hands   with metal  blank wire or other conducting material as that will cause an  electric shock and possibly caus
14. ring point as received energy  irrespective of the real energy  direction or     2  registration with reversal preventing device     The energy meter meets the requirements of Directive 2004 22 EC of the European parliament and the council of  31 March 2004 on measuring instruments     Certification was based on compliance with the following harmonised standards     EN 50470 1  2006     EN 50470 3  2006     Valid until    Electricity metering equipment  a c   part 1  General requirements  tests and test  conditions   Metering equipment  class indexes A  B and C    Electricity metering equipment  a c   part 3  Particular requirements   Static meters for  active energy  class indexes A  B and C     June 11  2020    The results are recorded in thefollowing annex  test report 70965037 TDT 6356 10           G  4  ir  P J J G  Nabuurs  Managing Director    The investigation reported here does not confer any right to use an approbation mark granted by KEMA     Integral publication of this certificate and adjoining reports is allowed  pan  This certificate is issued provided that neither KEMA nor the RvA assumes any liability     KEMA Nederland B V  Utrechtseweg 310  6812 AR Arnhem  The Netherlands P 0  Box 9035  6800 ET Arnhem  The Netherlands    T  31  0 26 3 56 2215 F  31  0 26 4 42 6211 C amp M kema com www kema com trade register Arnhem 09080262       DMMetering   2011    Experience you can trust      5  User manual 0014    DMMeteringg  2011       1 4 Type number table     The P
15. s are recorded in the following annex  test report 2113897 TDT 6319 10     KEMA Quality B V     a       ir  P J J G  Nabuurs  Managing Director       Notified  body number 0344  The investigation reported here does not confer any right to use an approbation mark granted by KEMA     Integral publication of this certificate and adjoining reports is allowed   This certificate is issued provided that neither KEMA nor the RvA assumes any liability     KEMA Nederland B V  Utrechtseweg 310  6812 AR Arnhem  The Netherlands P O  Box 9035  6800 ET Arnhem  The Netherlands  T  31  0 26 3 56 2215 F  31  0 26 4 42 6211 KAL kema com www kema com handelsregister Arnhem 09080262  Experience you can trust        DMMetering   2011  4  User manual 0014          CERTIFICATE    EC Type examination certificate 6356 10    Manufacturer  Contact person  Address   Postal code  Place  Country    Instrument  Mark   Type    Register  Accuracy Class    Measurement range    Temperature range  Use  Protection Class    Environmental class    Registry method    Inepro Metering BV  D  van der Vaart  P O  Box 92   2450 AB  Leimuiden  The Netherlands    Electronic single phase two wire energy meter   Direct connected   PRO 1TE   Mechanical   B   230 V   5 45  A   50 Hz   1000 or 2000 imp  kWh    10  40   C   Indoor   II   M1  E2   2 options are available by selection per interconnection of soldering islands     1  bidirectional method with always positive register  the meter always counts the  energy of the measu
    