Home

Senses SV series industrial monitor user manual

image

Contents

1. The panel itself can be from 1 6 to 16 0mm thick Strengthening may be required for the panel Be sure to consider the weight of the monitor when designing the panel Page 15 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual 1 6 16mm Note To enhance the Senses SV19 SV17 monitor s maintainability operability and ventilation allow at least 35mm clearance between the monitor and any other objects The clearance must be large enough to allow you to insert or remove expansion boards and to attach connectors Side View Rear View 10 Unit mm Page 16 of 25 IT and Instrumentation for industry z Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual 2 3 Wall Mounting Optional These monitors are designed to support wall mounting applications There are three accessory items to support this feature e Wall mounting bracket x 1 pc e Binding head amp washer screws M4x0 7PxL6 0mm x 4 pcs e Truss head screws TTS 4 3 5x10mm black x 4 pcs Installation instructions 1 Refer to hole location in section 1 4 Dimensions Screw the truss head screws to the hole location on the wall Note Do not tighten the screw when mounting the monitor The mi
2. manual 1 4 Dimensions Lz7e rs9 365 8 wig aJOH Bunun IO L o LJ o o For Senses SV19P Rack or panel mount Page 7 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual wig yNo nd jeuog t7erso9 For Senses SV19F Open frame Page 8 of 25 IT and Instrumentation for industry z Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Pane Gul out Cb For Senses SV17P Rack or panel mount Page 9 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Pane Qul cut DIM For Senses SV17F Open frame Page 10 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual 1 5 1 O Inputs e For Senses SV19 monitors 6 543 2 1 SV19 DC Inputs 1 T S Port D sub optional This connector will be present
3. 5 connector can be connected to the system via the external D Sub15 connector located on the bottom side of the system unit 4 AV Port This connector can be connected to the system via the external connector located on the bottom side of the system unit 5 S Video Port This connector can be connected to the system via the external connector located on the bottom side of the system unit 6 T S Port D sub optional This connector will be present only if a touchscreen is installed It must be connected to the RS 232 port of the PC The touchscreen cable is included with all orders which include the touchscreen option Remark SV17 only supports one display input Please do not plug in multiple displays at the same time Page 12 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Chapter 2 System Setup This chapter details the system parts and components with figures Sections include e System Configuration Panel Mounting Wall Mounting Rack Mounting Desktop Stand 2 1 System Configuration The figure below shows the front and rear views of Senses SV19 SV17 monitors WGVOc EXT MENU SH Se O 6 5 4 3 2 1 Control Keypad For Senses SV19 Page 13 of 25 IT and Instrumentation for industry z Amplicon Sales 44 0 1273 570 220 Website www amplico
4. Exit the LCD Setting Page 24 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Image Adjust 1024x768 100Hz OSD Setting Adjust OSD setting Recall Previous Setting Monitor will recall the previous setting Sharpness Adjust Adjust Monitor s sharpness setting Use A or V button to increase or decrease the setting Page 25 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com
5. Senses SV series industrial monitor user manual Industrial Monitors Senses SV series Senses SV19 SV17 User manual Issue A Part No 85090084 Page 1 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Copyright Copyright 2008 Amplicon Liveline Ltd All rights reserved This publication including all photographs illustrations and software is protected under international copyright laws with rights reserved No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written consent from Amplicon Liveline Ltd Acknowledgements All product names or trademarks are properties of their respective owners Disclaimer This instruction manual is supplied to provide the user with sufficient information to utilise the purchased product in a proper and efficient manner The information contained has been reviewed and is believed to be accurate and reliable However Amplicon Liveline Ltd accepts no responsibility for any problems caused by errors and omissions Specifications and instructions are subject to change without notice The Senses SV series industrial monitors are ROHS compliant Page 2 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Ema
6. d that you spray the liquid cleaner on a cloth first before wiping the screen 4 Avoid using sharp objects to operate the touchscreen Scratches on the touchscreen may cause malfunction or internal failure to the touchscreen 5 These flat panel displays can be susceptible to shock or vibration When assembling the Senses SV19 SV17 make sure they are securely installed 6 Do not open the system s back cover If opening the cover for maintenance is a must only a trained technician is allowed to do so Integrated circuits on computer boards are sensitive to static electricity To avoid damaging chips from electrostatic discharge observe the following precautions v Before handling a board or integrated circuit touch an unpainted portion of the system unit chassis for a few seconds This will help to discharge any static electricity on your body v When handling boards and components wear a wrist grounding strap available from most electronic component stores Page 4 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Chapter 1 Introduction This chapter contains general information and detailed specifications of the Senses SV series SV19 SV17 industrial monitors Senses SV19 19 LCD industrial monitor and touchscreen optional Senses SV17 17 LCD industrial moni
7. er manual Appendix Appendix A Supported Input Timing Modes Supported Input Timing Modes The following timings are already programmed into the unit The input synchronous signals are automatically recognized Display Size Vsync Hz 640x350 70 640x400 70 640x480 60 640x480 72 640x480 720x400 800x600 5 7 6 7 1024x768 7 1152x864 75 7 0 0 800x600 2 0 0 0 Page 20 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Appendix B OSD Operation Function Description of OSD Menu Main Screen 1024x768 100Hz Signal Select Signal Select 1024x768 100Hz2 Signal Select a ee ee eae Page 21 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual VGA Input Setting Monitor s Input to VGA DVI Input Setting Monitor s Input to DVI AV Input Setting Monitor s Input to AV S Video Input Setting Monitor s Input to S Video Exit Exit the LCD Setting Video Adjust 1024x768 100Hz Wie Brightness Adjust Adjust Monitor s Brightness Use A or V button to increase or decrease the setting Contrast Adjust Adjust Monitor
8. il sales amplicon com Senses SV series industrial monitor user manual Table of Contents Safety Precautions 4 Chapter 1 Introduction 5 1 1 General Description 5 1 2 Features 6 1 3 Specifications 6 1 4 Dimensions 7 1 5 IO Inputs 11 Chapter 2 System setup 13 2 1 System Configuration 13 2 2 Panel Mounting 15 2 3 Wall Mounting Optional 17 2 4 Rack Mounting 18 2 5 Desktop Stand Optional 18 Appendix 20 Appendix A Supported Input Timing Modes 20 Appendix B OSD Operation 21 Page 3 of 25 IT and Instrumentation for industry z Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Safety Precautions Before getting started please read the following safety information 1 Be sure to ground yourself to prevent static charge when installing the internal components Use a grounding wrist strap and place all electronic components in any static shielded devices Most electronic components are sensitive to static electrical charge 2 Disconnect the power cord from the Senses SV19 SV17 monitors before installation Be sure both the system and the external devices are turned OFF Sudden power surges could damage sensitive components Make sure the monitor is properly grounded 3 Turn OFF the monitor power supply before cleaning Clean the system using a cloth only Do not spray any liquid cleaner directly onto the screen It is recommende
9. n com Email sales amplicon com Senses SV series industrial monitor user manual 6 5 4 3 2 1 Control Keypad For Senses SV17 1 Power switch Press this button to turn the monitor on off 2 Power LED When the light is green the power is on with an input signal When the light in flashing power is active with no input signal 3 SEL To scroll up the menu To increase the value of selected item 4 SEL To scroll down the menu To decrease the value of selected item 5 Menu Press this button to turn on off the OSD On Screen Display main menu Press this button to activate selected items 6 Exit Press this button to exit leave the selection menu Page 14 of 25 IT and Instrumentation for industry z Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual 2 2 Panel Mounting Two accessory items are needed for this application e Mounting bracket x 8 pcs e Pan head screws M4x0 7PxL45 0mm x 8 pcs Installation instruction 1 Find a plate and cut off a window refer to 1 4 Dimensions for the dimension details 2 Screw the mounting bracket to the unit 3 Combine flange nuts with box head screws and then screw to the mounting bracket to tighten the unit Note To obtain the maximum degree of moisture resistance be sure to mount the Senses industrial monitor on a smooth flat surface
10. nimum space between the wall and the top of screw should be 1 6mm 2 Mount the wall mounting bracket to the back cover of the unit 3 Mount the unit to the wall Page 17 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual 2 4 Rack Mounting Installation instruction 1 Remove 8 seal pads in front panel 2 Senses SV19 SV17 can be mounted directly to standard 19 industrial rack cabinets There are four screw holes on each side of front panel 2 5 Desktop Stand Optional 5 000 Side View These monitors are designed to support desktop stand applications Two accessory items are needed for this application e Wall mounting bracket x 1 pc e Binding head amp washer screws M4x0 7PxL6 0mm x 2 pcs Page 18 of 25 IT and Instrumentation for industry m Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Installation instruction 1 Mount the wall mounting bracket with the binding header amp washer screws to the back over of the monitor 2 The monitor can now stand on a desktop Page 19 of 25 IT and Instrumentation for industry z Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor us
11. only if a touchscreen is installed It must be connected to the RS 232 port of the computer The touchscreen cable is included with all orders which include the touchscreen option 2 DVI Port This connector can be connected to the system via the external DVI connector located on the bottom side of the system unit 3 VGA Port D sub This D Sub15 connector can be connected to the system via the external D Sub15 connector located on the bottom side of the system unit 4 AV Port This connector can be connected to the system via the external connector located on the bottom side of the system unit 5 S Video Port This connector can be connected to the system via the external connector located on the bottom side of the system unit 6 DC 12V This connector will be connected to the DC 12V Switching Power Supply Remark SV19 only supports one display input Please do not plug in multiple displays at the same time Page 11 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual e For Senses SV17 monitors 6 543 2 1 SV17P Inputs SV17F Inputs DC 12V This connector will be connected to the DC 12V Power Supply 2 DVI Port This connector can be connected to the system via the external DVI connector located on the bottom side of the system unit 3 VGA Port D sub This D Sub1
12. ontrols OSD enables user adjustments of on screen display settings 1 2 Features e High contrast color 19 0 17 0 SXGA TFT LCD display support resolution up to 1280x1024 e Heavy duty steel chassis with NEMA4 IP65 compliance e Resistive touchscreen capacitive touchscreen or tempered anti reflection glass options e Multi scan function supports SXGA XGA SVGA VGA VGA Text PC 9801 MAC e High Brightness and Ultra wide viewing angle with anti glare features e Power management system conforms to VESA DPMS standard e Advanced OSD control for picture quality adjustment e Supports VESA ARMS Desktop Stand e Rear Panel Wall or Rack mounting 1 3 Specifications e Construction Heavy duty steel chassis e Control OSD On Screen Display control pad on front side e Mounting Support Panelmount VESA arm mounting Rackmount and Wallmount optional e Net weight 9 46 Kgs for Senses SV19P e Net weight 8 32 Kgs for Senses SV17P e Dimension main body size o SV19P 482 0 W X 399 0 H X 59 eee o SV19F 482 0 W X 399 0 H X 59 5 o SV17P 482 0 W X 360 0 H X 60 0 o SV17F 482 0 W X 360 0 H X 60 0 e Operating Temperature Range 0 C 50 C e Relative Humidity 20 90 non condensing D D D YS Ss SS Page 6 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user
13. s Contrast Use A or Y button to increase or decrease the setting Exit Exit the LCD Setting Page 22 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Audio Adjust The Senses SV19 SV17 do not support Audio 1024x768 100Hz Se Colour Adjust 1024x768 100Hz Automatic Colour Tuning Monitor will automatically tune the colour setting Manually Colour Tuning Adjust colour setting Use A or Y button to increase or decrease the setting Exit Exit the LCD Setting Page 23 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Image Adjust 1024x768 100Hz LLLLLEI Automatic Image Tuning Monitor will automatically tune the image setting Horizontal Width Adjust Adjust Monitor s horizontal width setting Use A or Y button to increase or decrease the setting Horizontal Phase Adjust Adjust Monitor s horizontal phase setting Use A or Y button to increase or decrease the setting Horizontal Position Adjust Adjust horizontal position setting Use A or button to increase or decrease the setting Vertical Position Adjust Adjust vertical position setting Use A or button to increase or decrease the setting Exit
14. tor and touchscreen optional Chapter 1 includes the following sections e General Description e Features e System Specification e Dimensions e 1 0 Inputs 1 1 General Description The Senses SV19 SV17 are industrial 19 0 and 17 0 LCD monitors respectively They come with slim light and reliable features to replace traditional bulky CRT for industrial application Their unique front panel design is suited to open frame mounting Senses SV19F SV17F or rack and panel mounting Senses SV19P SV17P The monitors have VGA in DVI and S Video standard interfaces for different input sources from computer systems or multimedia systems that let you upgrade the display without changing anything from your system For HMI applications you can choose a resistive touchscreen capacitive touchscreen or glass interface to meet your application requirements These LCD monitors comprise colour active matrix thin film transistor TFT liquid crystal display to provide superior display performance and a maximum resolution of 1280x1024 which is ideal for displaying complex graphics and high definition images Other outstanding features that enhance this LCD monitors performance are Plug amp Play compatibility and OSD On Screen Page 5 of 25 IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Senses SV series industrial monitor user manual Display c

Download Pdf Manuals

image

Related Search

Related Contents

Globalsat Technology GH-615B/GH  Handbuch PP013, PP014, PP015, PP016  PDF Guía del usuario  PDF user`s guide  

Copyright © All rights reserved.
Failed to retrieve file