1. Contact to Current Loop Current Terminal 1 fi m Voltage Cable Voltage Bridge Closed Voltage Bridge Open Fig 7 1 Voltage jumper with test voltage connection Procedure 1 Connect the meter to the terminals of the testing device as shown in the meter connection diagram and according to the usual testing methods Remove the access lock sliding piece if present 2 To connect the test voltage use a connecting cable with a contact pin of 2 5 mm diameter and 40 mm length 1 mm Insert this pin in the opening provided on the front of the terminal block right above the measuring terminals A Keep voltage cables free from voltage when inserting Touching live contact pins can be fatal 3 After testing remove the cable voltage free from the terminal cover The spring closes the contact and the voltage is connected again Insert the access lock sliding piece again and if necessary seal it D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 44 48 Maintenance 7 1 5 Creep Test A test voltage U of 1 15 U is used for the creep test no load test according to IEC 62053 21 e g U 265 V with U 230 V Procedure 1 Disconnect the meter from the mains for at least 10 seconds 2 Switch on the test voltage U and wait approx 10 seconds Both the active circle and the reactive diamond anti creep indication must now be permanently on The energy direct
2. minus B h O Q _ underscore _ C P p 0 H D d Q H 1 H E E R r 2 d F F S 5 3 3 G b T t 4 H H h U u 5 5 i V U 6 b d J W U 7 1 K X 7 8 H L L Y y 9 g M n Z d Display variations Some characters might be displayed differently depending on module and meter version Characters which can t be represented with the 7 segment display will be replaced by an underscore there are also meter versions with a slightly different character set E g the characters that cannot be shown are represented with a lower o 5 2 9 Meter Display List Available Items with OBIS Codes OBIS code Item FF Error code always first in the list C 1 0 Meter identification 8 character string 0 0 Customer identification 16 char string Readout 0 0 1 Customer identification characters 1 8 Display 0 0 2 Customer identification characters 9 16 Display C 1 1 Manufacture identification 8 char string C 90 1 IEC address of meter 1 8 0 Total active energy import 1 8 X Active energy import rate X X 7 1 6 2 8 0 Total active energy export 2 8 X Active energy export rate X X 7 1 6 D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 32 48 Operation OBIS code Item 3 8 0 Total reactive
3. Terminals are available with an opening diameter of 8 5 mm and 9 5 mm Terminals with opening diameter of 8 5 mm and 9 5 mm have the same position on the terminal block Fig 3 7 Terminal layout and dimensions Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Installation De installation 19 48 4 Installation De installation 4 1 Mounting the Meter The meter should be mounted as follows on the meter board or similar de vice provided for this purpose see also section 3 4 Dimensions 1 Find the correct position for the meter Ensure there are no wires underneath the holes to be drilled Define the desired form of fixing open or covered meter mounting Ensure with a phase tester or universal measuring instrument that the connecting wires are not live A 179 mm for open mounting 155 mm for covered mountin 52 5 mm 105 mm Fig 4 1 Drilling plan 4 Mark the three fixing points suspension triangle as shown in the drilling plan Fig 4 1 on the mounting surface provided Drill the three holes Unscrew the meter terminal cover For open meter mounting insert the meter suspension eyelet which is supplied in the terminal cover into the corresponding opening at the rear side of the meter until the suspension eyelet engages see Fig 4 2 Fig 4 2 Meter suspension eyelet 8 Fit the meter with 3 fixing screws on the mountin
4. E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 42 48 Maintenance 7 Maintenance The meter is maintenance free The following points should be regularly checked e sthe meter dry and clean particularly display and optical interface e sthe meter in operation and serviceable displayed data reasonable e Are all seals undamaged e Is there an error recorded based on periodical internal self tests since the previous check check on the display or readout list e Havethe values of the energy registers changed within reasonable limits since the last data readout no unauthorised manipulations Continue with section 6 3 Repairing Meters in case of irregularities 7T 1 Meter Testing The meters are calibrated during manufacturing A recalibration later on is not possible Meter tests should be performed at periodic intervals accor ding to the valid national regulations either on all meters or on specific ran dom samples For this purpose the meters must be removed as described in section 4 5 Disconnecting the Meter and replaced by a substitute meter for the duration of the test 7 1 4 Higher Register Resolution Display example The meter features a certification display sequence which allows registers to be displayed with 3 decimal places See 5 2 5 Display Sequence This sequence is entered by pressing the display button for more than 5 s It is left again if the display button is not pr
5. nel of energy supply companies responsible for system planning installa tion and commissioning operation maintenance decommissioning and disposal of meters The technical data and functional description of the ZCF100 meters can be found in separate documents e D000030926 Technical Data ZCF100Ax Cx series 2 e D000028645 Functional Description ZxF100Ax Cx series 2 D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 6 48 Description of Unit 1 Description of Unit 1 1 General View Fig 1 1 General view of meter 1 2 Purpose of Use D Restrictions for meters with software versions M51 and M52 The meters may not be used in networks with significant disturbances in the frequency range of 2 kHz to 150 kHz since the intended operating con ditions of the meters according to the harmonised standards EN50470 1 and EN50470 3 assume no significant noise currents and voltages in this frequency range Such significant disturbances occur for instance in large photovoltaic sys tems influence of the inverters with high emissions of extreme harmonics The ZCF100 meters record active and reactive energy consumption in all 1 phase 2 wire networks They are directly installed in the supply line by the energy supply company and are read regularly for billing purposes The data is displayed on an LCD and is also available via optical interface and with an AMR Module via CS PLC modem
6. C 5 0 0242 on z Valency Bit number The status register is available to be read via communication public or optical or displayed on LCD in hexadecimal form Some meter configuration contains also a special code with is 4 bytes long All reserved or not used bits are set to 0 by default Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Operation 37 48 5 5 4 Data Readout Procedure via Optical Interface or AMR Module Start the AMR Module according to the associated user manuals Connect the cable of the reader head to the Hand Held Terminal Place the reader head in the marked position on the face plate of the meter The reader head is held magnetically Start the data readout with the Hand Held Terminal 5 Remove the reader head from the meter again after readout Readout list The data read out are recorded in the form shown below The scope and example sequence of values in the readout list is determined by parameterisation Info flow Readout list Significance m IS Opening string initial sign on lt LGZOZCF100AC MXX RT Unit recognition for the specific manufacturer no identification of data MXX SW version lt ACK gt 0Z0 94 e Acknowledgement Z Transmission rate lt STX F F 00 R r Start of text Error message readout flag C 1 1 0000000074892473 amp r Meter identification number
7. GSM GPRS modem etc When provided with transmission contacts the meters can also be used as transmission contact meters for telemetering The rates can be controlled internally or externally with control inputs on the AMR Module With an AMR module the meters can also be used to record counting pulses of other physical media e g water or gas volumes or to directly transmit values recorded by other measuring devices Any other application of these meters is regarded as abuse Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Description of Unit 7 48 1 3 Field of Application Basic series Disconnector ZCF100xB only Extensions Parameterisation The basic version provides energy registers for tariffication a red test diode for active or reactive energy an optical interface for meter reading and an interface for various communication forms This interface is protected against fraud and is independent of the module suppliers The exchangeable AMR Module is situated outside the calibration liability The functionality of this meter is suitable for smaller consumers e g for households The function of the disconnector is customer specific and is defined by the communication module Possible uses anti tampering e g disconnection in case of tampering with magnets load limitation fuse control remote disconnect e g in case of change of tenant prepayment The status of
8. In the main field 100 and the characters to define whether it is an active or a combi meter respectively a meter with or without discon nector e g 100 Ab 100 AC 100 bC 100 bb In the index field the software version e g 21 for version M21 or with alternative format 2300 for M23 0 0 Then the service display appears for the parameterised start up time If the start up time for the service display is zero the display starts directly with the main display Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Operation 29 48 Service display Main display Example The service display allows tests to be carried out by allowing registers to be displayed at higher resolutions It provides information to assist the installer during installation or during subsequent testing of the network status The service display may also include data which can give information about the state of the meter during work in the field or in the test facility The service display is accessed when the meter is first powered up and on a long press more than 5 seconds of the display button in the main dis play Exception Ifthe display button is pressed long while the consumption since last reset is displayed the register is reset instead The items in the service display maximum 63 can be scrolled through with short presses less than 5 seconds of the display button When the end of the sequence is r
9. Phase voltage indication Tamper alert indicator 10 Index field five digits with 7 8 or 11 segments 11 Disconnect icon 12 Media icons water heating gas electricity 0 00140 l5 5 2 2 Explanation of LCD Elements Value field Unit indications Active energy direction indication Reactive energy direction indication For the purpose of this document flashing LCD segments will be shown in grey colour Up to 8 digit values can be displayed in the value field The 7 segment dig its are able to display numeric data or limited alpha numeric text Additional decimal points and colons enhance the 7 segment digits This allows the representation of values with decimal places as well as date and time for mats VA kWarh m MJ GJ With the unit indications below and on the right side of the value field the following units can be displayed V A kWh kVah kVarh kW kVa kVar m MJ GJ The unit displayed indicates which register is being viewed gt positive active energy direction imported from power company Za negative active energy direction exported to power company 4 9 positive reactive energy direction v negative reactive energy direction Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Operation 25 48 Quadrant Reactive anti creep indication Active anti creep indication Media icons Disconnect icon Tamper alert i
10. e forthe protection of persons e prevention of material damage e andthe training of personnel Landis Gyr AG provides training courses for this purpose on specific equipment please contact the relevant agent if interested D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 14 48 Safety 2 3 Safety Instructions The following safety instructions must be observed at all times The meter connections must not be under voltage during installation or when opening Contact with live parts is dangerous to life The relevant main fuse should therefore be removed and kept in a safe place until the work is completed so that other persons cannot replace it unno ticed Local safety regulations must be observed Protection earth connection must not be switched with the disconnetor Only useful tools have to be used This means a screw driver has to have the correct size for the screws and the metallic part of a screw driver has to be insulated The meters must be held securely during installation They can cause injuries if dropped Meters which have fallen must not be installed even if no damage is apparent but must be returned for testing to the service and repair de partment responsible or the manufacturer Internal damage can result in functional disorders or short circuits The meters must on no account be cleaned with running water or with compressed air devices Water penetrating
11. the disconnector is displayed on the meter but the disconnector is control led by the communication module If you need detailed information on the functionality of your disconnector please consult the user manual of the communication module installed The basic series can be extended with various AMR Modules for additional functions and communications e Multirate import export with external rate control e SO pulse output e Communication via PLC GSM GPRS or other media The meter functions which can be used in the system are defined by the module e g a 2 rate module is not able to control 6 rates in the meter Therefore meter and module together define the functionality range which can be used As the meter has a wide range of configuration possibilities a specific behaviour can in some cases differ from the description below The meters can be parameterised i e specific parameters can be set with software so that the meters can be supplied according to the specific wishes of the relevant utility Retroactive modification of the parameters is not possible The parameters stored in the meter are protected against unauthorised overwriting Details about parameter settings can be found in the functional description 1 4 Characteristics The meters have the following characteristics e Recording of active and reactive energy in all 4 quadrants ZCF100Cx or recording of active energy imported and exported ZCF100Ax
12. 1 1 8 0 000065 3 kWh Dee Total active energy import 2 8 0 000003 5 kWh g e Total active energy export 1 8 1 000021 5 kWh R Active energy import rate 1 lt 1 8 2 00043 8 kWh R F Active energy import rate 2 lt 2 8 1 000001 5 kWh R Active energy export rate 1 lt 2 8 2 00000 0 kWh R r Active energy export rate 2 lt C 5 0 02 4 e Status code phase fail flag lt ETX gt lt BCC gt End of text Checksum Fig 5 7 Example of readout list Valid for readout with E35C modules For other modules other codes could be delivered e g equal to error display values lt ACK gt CR lt LF gt lt STX gt lt ETX gt lt BCC gt ASCII character not visua lised in the data readout list The code Z in the data readout acknowledge string identifies the required transmission rate for the data to follow Code Z Transmission rate 0 300 bps 600 bps 1200 bps 2400 bps 4800 bps 1 2 3 4 5 9600 bps D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 38 48 Operation 5 5 5 Addressability of Meter The meter monitors every communication request received over the optical port or the AMR interface The AMR interface can be controlled by various inputs from the module e g cs interface input With SW versions M52 or higher the meter will react to the commu
13. De MMOS EE 26 5 2 5 Display Sequence rene nrn nn rr nnt niin hart nar r nain sa rns rena rn ri rnnin 27 920 DISPlay CMECK 4 5 eck eens es CHEM 30 9 2 1 Error DISDIAY m 30 5 2 8 Text Messages on Display 30 5 2 9 Meter Display List Available Items with OBIS Codes nenn 31 5 2 10 Display Status Messages nenne nnn net nn rr nnn inna innare rnit niin nain nina 33 D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 4 48 Table of contents 5 2 11 Energy Efficiency Items in the Meter Display 33 5 3 Optical Test OUtDUlL iiii eta eee tbi ine 34 9 4 Opticalnterace qoe ce RETE DER PINE EE 34 5 5 Data RREAGOUE mr s 35 9 9 4 EG 62056 21 e E 35 5 5 2 Readout Configuration EE 35 5 5 3 Readout Status COME C90 rm 36 5 5 4 Data Readout Procedure via Optical Interface or AMR Module 37 5 5 5 Addressability of a ae 38 Hr vu eor M A 39 6 Operating lui NN o oO em 39 6 2 Error Pii c 39 6 2 1 Structure of an Error Code uci iae eek by pae ae 39 6 2 2 Error Code Description 40 6 3 Repairing ME 41 T Maintenance uni 42 Ded Meter e EE 42 7 1 1 Higher Register Resolution a era une see ee ah 42 Bel CRM NO 42 7 1 3 Optical Test Outputs sueesuusssesssussssssssssssseeeeen nenne tree rrr reri nennen nn 43 7 1 4 Connection to a Meter Testing De
14. Descriptions Example Two errors are shown as Another two errors occur The displayed error code reads Error register Valency F F 00002001 F F 00028000 F F 0002A001 Byte 4 Byte 3 Byte 2 les IB 2T1 0 seggt zeben 7 6 54 3 2 1 jo alpha rr 8 4 2 1 m Bt N zi Co Bt N wech E HAAK d SS 00024001 Error code The following error code descriptions apply for E350 series 2 meters Error code descriptions for E350 series 1 meters can be found in the functional description D000028645 The allocation of the defined errors to the individual bits of the error register and the error code of the single errors is as follows Byte Bit Valency Error code Error code description 1 00 00 00 01 Insufficient time to complete power failure 00 00 00 02 More than 32 consecutive attempts to communicate with or initialise the MMI devices have failed 00 00 00 08 00 00 00 80 Not used Reserved Not used Not used Not used Reserved Not used Not used Not used Not used Not used 00 00 20 00 Calibration value failed checksum 00 00 40 00 Power fail data failed checksum NI OO oa AION gt I OINI ani oa BR OJN Co FR NM gt CO RI M A ol RI M gt or E 00 00 80 00 Failed checksum when restoring registers from EE
15. Identifier value units The maximum transmission rate is 9600 bps The response message identi fies the software version and the IEC 62056 21 transmission rate mode used The meter provides also a manufacturer specific mode C C which delivers only a part ofthe read out list start and end item are configurable during pro duction This can be used for fast read out for frequently required values 5 5 2 Readout Configuration Readout and display items Readout error code F F The readout items their order in the list along with the number of decimal places for the registers are specified in the configuration The register sizes can have up to 6 integer digits and up to 3 decimal places This is independent on the display configuration The readout list similar to the display list consists of a number of specified items The customer specifies the readout sequence This sequence is set at the factory All items are identified with OBIS codes when read out The items that can be placed in the readout list in any order except for Error code which is always first in the list are listed in section 5 2 9 Meter Display List Available Items with OBIS Codes on page 31 Most of these items can be included in the read out list The error code consists of 8 bits and describes the following Bit number Allocation Not used MMI initialisation or communications failure Error accessing EEPROM Calibration data is corrup
16. With small conductor cross sections e g 4 mm the connecting line must be placed in the indentation stamping of the current loop so that it cannot shift sideways when tightening the terminal screws Ensure that the con necting line remains in the indentation when tightening Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Installation De installation 21 48 Indentation stamping for smaller connection lines Current loop conductors Fig 4 4 Cross section through current loop conductors D Insufficiently tightened screws Insufficiently tightened screws of the connections can lead to increased power losses at the terminals and therefore to undesirable heating A contact resistance of 1 mQ causes a power loss of 6 4 W at 80 A A Insulate to correct length Touching live parts is dangerous to life Shorten the stripped part of the connecting wire if bare wire is visible above the terminal edge A Do not withdraw connecting wires with closed terminals Never withdraw connecting wires with the terminal closed since this could damage the terminal 4 3 Checking the Connections Before putting the meter into operation check and correct if necessary the following points to ensure a correct connection 1 Has the correct meter identification number been installed at the measuring point of the relevant consumer 2 Is the calibration connection closed s
17. and readout is performed with a handheld terminal refer to section 5 5 Data Readout 5 1 1 Display Button The display button is located on the front cover on the right of the LCD Display button Fig 5 1 Display button By pressing the display button the display mode or the displayed value can be changed see section 5 2 4 Display Definitions 5 1 2 Disconnector Button The disconnector button option is located on the terminal cover EZ Disconnector button Fig 5 2 Disconnector button If the disconnector button is pressed the disconnector opens and or closes depending on parameterisation i e a closed disconnector can always be opened with the disconnector button whereas closing an open disconnector needs an additional permission from the meter D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 24 48 Operation 5 2 Liquid Crystal Display LCD 5 2 1 Basic Layout The basic layout shows all indication possibilities of the LCD 123324 5 LLL s pa 4 9 em Gm Gm EM Gm Gm Gm m m 5 OOOO 0 0 On Li LI LI LGLGLL L3LTEYS GJ VA kWarh wv v v v Fig 5 3 Basic layout of LCD Reactive anti creep indication Active energy direction indication P import P export Reactive energy direction indication Q import Q export Active anti creep indication Value field eight 7 segment digits Unit indications 6 arrow symbols for rate indication
18. can be oper ated only by the AMR module The reactive energy Rc Ri is allocated to the 4 quadrants as follows R 4Q 4Q PM Er kvarh Rc Ri kvarh Quadrant II Quadrant Export A z A Import kWh Quadrant IIl Quadrant IV kWh Ri Rc kvarh kvarh P lt cb P 4 Ja R Fig 1 2 4 quadrant measurement Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Description of Unit 11 48 Channel configuration To each of the 8 available channels a measured quantity can be assigned by parameterisation The following table shows some of the most common measured quantities used Value OBIS Direction Quadrant s Unit A 1 8 0 Import I IV kWh A 2 8 0 Export II UI kWh A EA 15 8 0 Combined sum E He 111 IV kWh R 3 8 0 Import I kvarh R 5 8 0 Import kvarh R 6 8 0 Import II kvarh R 4 8 0 Export II IV kvarh 1 7 Instantaneous Values Instantaneous values are updated every second The following instantaneous values are available Measured value Resolution Start value Max value Voltages L1 L2 L3 1V 170 V 440 V Currents 11 12 13 0 01 A 0 2A 120 A Frequency 0 1Hz 47 Hz 53 Hz Power Factor 0 1 1 1 Power 0 01 kw 1 gt 0 075 1 Imax If no value is available can be shown e g if in creep or value below st
19. can cause short circuits 2 4 Radio Interference D Possible radio interference in residential environments This meter is normally a class B product In combination with some commu nication modules it can become a Class A product In a domestic environ ment this may then cause radio interference in which case the user may be required to take adequate measures Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Mechanical Description 15 48 3 Mechanical Description 3 1 Housing The internal construction of the meter will not be described here as the meter is sealed after calibration and verification Fig 3 1 Front view of meter Suspension hanger in upper position Suspension hanger in lower position Display button LCD Optical interface Front cover face plate with laser marking for details see Fig 3 2 Test diode red AMR Module compartment Terminal block cover 10 Screw with sealing point manufacturer or utility seal 11 Disconnector button A terminal block with all connecting terminals is located under the terminal cover On the terminal cover a sealing point for an utility seal prevents un authorised access to the phase connections and therefore help to avoid unrecorded power consumption Kess UNS D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 16 48 Mechanical Description 3 2 Face Pl
20. will be controlled by the installed module Please refer to the manual of the module for valid operation mode Alternatively to this indication a display of the disconnector status can be in the installed module and the display on the LCD can be disabled IX This icon is switched on when the meter has detected the tamper event parameterised either terminal cover or strong magnetic field L The phase voltage indication is switched on if the phase voltage is present wow w vV VvV Vv The 6 arrow symbols indicate the active rate as marked on the face plate It can be parameterised whether the arrow symbol for the active rate is on or flashing D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 26 48 Operation Index field Up to 5 digit indices are displayed in this field which define the value in the value field with groups C D and E of the OBIS identification code see following section Examples 1 8 0 indicates that the status group D 8 of total group E 0 active energy import group C 1 is displayed in the value field 0 9 1 indicates that the local time is displayed in the value field 5 2 3 Displaying OBIS Codes Representation example For OBIS Object Identification System the structure A B C D E F applies The individual groups have the following significance A Defines the medium e g electricity gas heat or water related data Group A is repre
21. with up to 6 rates e Rate control performed via AMR module e Data display on LCD e Measuring elements in DFS technology Direct Field Sensor with excellent measuring characteristics including flat load curve high stability and good protection against interference e Active energy measurement accuracy Classes 1 and 2 IEC62053 21 and MID accuracy classes A and B EN50470 3 D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 8 48 Description of Unit e Reactive energy measurement accuracy Class 2 IEC62053 23 e Wide range measurement from starting current to maximum current e Serial interface with optical input output for automatic readout of data on the spot and for service functions e AMR interface connection to communication module for meter reading and tariff control according to IEC 62056 21 e Storage of event information e g power outages e Installation aids e g phase voltages and direction of energy Presence of phase voltage voltage value is displayed Visual output creep indicator on LCD Display of energy direction Power indication 1 5 Type Designation ZCF 1 10 A B e F s2 Network Type RES ZCF 1 phase 2 wire network Connection Type 1 Direct connection Accuracy Class active energy 10 Class 1 IEC B MID 20 Class 2 IEC A MID Measured Quantities A Active energy C Active and reactive energy Additional Functionality C Met
22. D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Operation 33 48 5 2 10 Display Status Messages Depending from configuration the following messages can appear on the end of a display list Messages Meaning FF 00000000 Error detected if error value FF gt 0 rEd Reverse rotating field detected td Terminal cover removal detected mFd Strong magnet field tamper detected btd Disconnector breaker tamper detected VoltAGE Low Voltage is lower than the configured threshold standard value 170 V Fig 5 5 Sample Message for magnet tamper detected 5 2 11 Energy Efficiency Items in the Meter Display If configured appropriately the display can list 4 new Software 2 M52 items intended to allow the consumer to easily monitor energy flow Item Display Content Remarks Import Energy Meter St1 Import Energy 1 8 0 Resettable Export Energy Meter St2 Export Energy 2 8 0 Resettable 24 Hour Energy Import Energy 1 8 0 Refresh 24h Consumption over last 24 h every 5 min 1 Week Energy 1 Import Energy 1 8 0 Refresh w Consumption over last week every 1 hour The resolution of these 4 displays is 1 W Import and Export Energy meter display These registers St1 and St2 are counting energy permanently The Import and the Export energy Meter values can be reset by applying a long button press whilst the register value is being displaye
23. Electricity Meters IEC MID Landis Gyr manage energy better Residential ZCF100Ax Cx E350 series 2 1 phase User Manual Date 20 12 2011 File name D000030875 E350 ZCF100Ax Cx 1 ph series 2 User Manual EN docx Landis Gyr D000030875 EN n 2 48 Revision history Revision history Version Date Comments a 19 01 2010 b 05 05 2010 c f 06 09 2010 g 16 10 2010 h 09 12 2010 k 17 03 2011 m 01 06 2011 n 20 12 2011 First edition New display list items Combined sum integrated in channel configuration section 1 6 SW version presentation updated Disconnector tamper added More detailed explanation of disconnector icon table of required measuring times updated display status messages added error and status code explanation extended addressability added restriction for SW version lt M52 added Meter display list corrected voltage current frequency power items Explanation efficiency registers updated Table Instantaneous Values updated Display status messages updated Meter tools added Minor formatting and text improvements Updating 1 8 Instantaneous values Section 5 2 5 Display sequence entirely updated main and service display Declaration of conformity replaced Note about restrictions for meters with software versions M51 and M52 added in section 1 2 Purpose of use Section 1 3 Advice deleted integrated into note in section 1 2 Section 2 3 Safety Instructions exp
24. PROM Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Service 41 48 Byte Bit Valency Errorcode Error code description 1 _ Not used 00 02 00 00 Error accessing EEPROM Not used 00 08 00 00 Reserved Not used 00 20 00 00 Reserved 00 40 00 00 Error restoring energy registers 00 80 00 00 Error saving energy registers Not used Not used Not used Not used Not used Not used Not used 80 00 00 00 Reserved zl lU OI Om AJOIN gt I OINI ony a RI w rm OH co i MI gt oOo R MI A gt oO BRI MI gt oO BRIM These errors cannot be cleared using the formatted write command C150 or by power cycling the meter Contact a Landis Gyr Service Centre for support 6 3 Repairing Meters The following procedure should be adopted if a meter repair is necessary 1 If installed remove the meter see section 4 5 and fit a substitute meter 2 Describe the error found as exactly as possible and state the name and telephone number of the person responsible in case of inquiries Please also state serial no and complete type designation no 3 Pack the meter to ensure it is not damaged during transport Use the original packing if available Do not enclose any loose components 4 Send the meter to an authorised service centre D000030875 EN n
25. anded with remark that PE must not be Switched with disconnector and only useful tool have to be used Section 5 2 7 Error Display modified Remark about module data added in section 5 2 9 Content of section 5 2 12 Error descriptions E350 Series 1 and Series 2 moved partly into functional description and partly to section 6 2 Error Codes Safety information about cleaning added in section 6 1 and modified in section 7 2 Terminology changes breaker disconnector baud rate transmission rate baud bps bits per second Minor formatting and text improvements Section 1 6 3 Adapted to software version M54 8 measurement channels Section 5 2 9 New display item Disconnector tamper counter Nothing in this document shall be construed as a representation or guarantee in respect of the performance quality or durability of the specified product Landis Gyr accepts no liability whatsoever in respect of the specified product under or in relation to this document Subject to change without notice Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Table of contents 3 48 Table of contents Revision histony ae REEL 2 Table of contents iii cce kr ve ER Te Rd a UE D E Ru IE E E ER E RR E eines 3 Introd CUON EE 5 Beerpong geen 6 1 1 General View een 6 1 2 Purpose of Use 2uunnsssnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnennnennnenn
26. arameters which have an influence on the display sequence must be defined in the configuration process D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 28 48 Operation These items are e Leading zeros can be enabled disabled for registers e Energy register displays can be defined with an integer part of 6 digits in exceptional cases 5 and with 0 1 2 or 3 decimal places Max 6 significant digits left of the decimal point are allowed Max 8 digits including decimal places are available e Active rate indication can be enabled or disabled e Flashing decimal point to indicate that the meter is in the certification display sequence Main display Meter start Service display power up Auto scrolling list Service list Value 1 Value 1 Jo Value 2 Value 2 i n Value n Value 3 Jo Recall list Melee I Consumption since reset Reset of in P register Value 5 lo ja Value 2 Value 6 jg Jo Value 3 Value y Jo Value x O short press of display button lt 5 s BB long press of display button gt 5 s Fig 5 4 Overview display sequences Power up During power up the type and software version of the meter is displayed for 1 0 seconds The display contains
27. art value 1 8 Anti Tampering and Tamper Prevention E350 meters feature four optional anti tampering functions e Detection of terminal cover opening e Detection of DC magnetic field e Sealable access lock to voltage connections e Detection of Disconnector tampering Disconnector meters only 1 9 Disconnector The ZxC100xB version of the E350 meter is equipped with a disconnector which is controlled via the communication module Various functions can be implemented e disconnection if credit has been used up e _ change to minimum power mode if credit has been used up e disconnection if max power has been exceeded over a specified time e others D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 12 48 Description of Unit The disconnector can either be controlled via the AMR module or manually with the disconnector button on the meter s terminal cover if parameterised accordingly see also section 5 1 2 Disconnector Button 1 10 Software Tools Landis Gyr meters are provided with optimum support by suitable software tools during all phases of their life cycle e The Landis Gyr MAP110 service tool for customers is used for the test and installation of meters and for servicing work on the spot Meter testing and certification Meter re parameter isation Meter installation For the list of functions of MAP110 please see MAP documentation and functiona
28. ate The face plate laser marking on front cover shows customer specific meter information eee DD DD LET Coi I COLO LOLOL COLI te XK prp VA kWarh Wiry viv v v Pa ALTE T T MEL S A Imp kWh Place for Customer property plate H impkvarn j 1000 TXXXXX 0120UK Fig 3 2 Basic layout of face plate Meter data Double protection insulation symbol Approval symbol CE conformity symbol Customer No Barcode Ownership designation Active rate The display button and the display are fully described in section 5 OROD 3 3 Connection Diagrams examples D Where to find relevant diagrams The diagrams relevant for the installation are shown on the terminal cover normally Fig 3 4 Connection diagram ZCF100AB with disconnector Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Mechanical Description 17 48 3 4 Dimensions The meter is only available with an extended terminal cover see Fig 3 5 Fig 3 5 Meter dimensions The extended terminal cover offers increased safety since the phase and neutral connecting wires are protected underneath The suspension triangle complies with DIN standards ELT UR Y g e Fig 3 6 Meter without terminal block cover D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 18 48 Mechanical Description
29. d The number of pulses per time unit depends on the meter constant as stated on the face plate When registering energy the test diode will flash for example at a rate of 1 pulse per Wh or VArh of energy recorded with a meter constant of 1000 pulses per kWh kvarh The pulse width is 10 ms Optical interface Test diode Fig 5 6 Optical test output and optical interface 5 4 Optical Interface Access to module over optical port All meters have an optical communications port see Fig 5 6 Ifthe AMR module supports this function both meter and module can be accessed via optical port In this case the AMR module has to be addressed The optical interface allows reading the meter s registers and identity in the field using a suitable device Hand Held Terminal or PDA The readout list is in full accordance with the provisions of IEC62056 21 The optical port is normally closed a wake up string is sent to the meter which activates the readout list With this communication channel software can be downloaded to the module Additionally an external user can send commands to the module and upload data from the module via the opto port All communication is half duplex i e data can either be transmitted or received at any point in time If the module communicates with the opto port the meter will not accept sign ons from either the opto port or the AMR port If the module wants to read the meter it must terminate the opto por
30. d on the meter working like a trip recorder in a car During power outage registers St1 and St2 are reset These both registers start after recover of power with the values of the energy registers of import or export energy St1 import value register 1 8 0 St2 export value Regis ter 2 8 0 24 hour and 1 week consumption registers These registers show the energy consumed during the last period of 1 week 24 h register period of 1 day The meter counts the time duration continuously but doesn t synchronise with a calendar clock Time during power outages is not included in the elapsed time measure ments of the registers 24 Hour Energy Consumption and 1 Week Energy Consumption D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 34 48 Operation E g for the 24 h register assume registration for 5 hours followed by 1 hour power outage Then completion of the 24 h registration will complete 19 hours following the end of the outage 5 h 19h 24 h After resumption of power following an outage the registers 24 Hour Energy Consumption and 1 Week Energy Consumption will display 0 until the first refresh occurs i e after 5 min and 1 hour respectively 5 3 Optical Test Output The test diode is used for meter testing It transmits visible red pulses equi valent to the currently measured value The switching between active and reactive mode at combimeters is done by comman
31. eached auto scrolling of the main display will start The number of displays max 31 their sequence whether they are con tained in the auto scrolling list or only in the recall list all displays of the auto scrolling list appear also in the first part of the recall list and the dis play duration for the items between 1 and 15 seconds can be parameter ised Up to 12 displays under the control of the AMR module can be in cluded in the main display The auto scrolling list of the main display is displayed e ifthe end of the service display or the recall list of the main display is reached e if the display button isn t pressed for a period configurable at manufac turing of between 5 and 60 minutes default 30 minutes or e after a long press of the display button more than 5 seconds in the service display It shows the end user the main consumption data e g the status of rated registers and total registers current instantaneous demand etc After the last display in the auto scrolling list it starts again If the number of displays in the auto scrolling list is set to 1 auto scrolling is switched off and the first display of the recall list is displayed continuously The recall list of the main display is accessed by a short press less than 5 seconds of the display button while the auto scrolling list is running A short press moves the display to the next item in the recall list Re peated short presses will scrol
32. ealable sliding piece inserted and sealed Are the screws for the phase and neutral connection tightened well Are all inputs and outputs connected correctly The house connection or consumer fuse wires must be present at the input terminals 1 4 those of the meter to the consumer at the output terminals 3 6 Mount the terminal cover after a successful check of the connections tighten its screws and seal it D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 22 48 Installation De installation 4 4 Commissioning and Functional Check A Do not touch live parts The main fuse must be inserted to put the meter into operation and for the functional check Without terminal cover there is a danger of contact with the terminals Touching live parts is a danger to life The installed meter should be put into service and checked as follows 1 Insert the corresponding main fuse The meter is on 2 Check whether the display appears correctly no error message and with no load connected that the anti creep indicators are constantly on 3 Connecta load and check whether the anti creep indicator for active energy disappears 4 Check whether the disconnector if present works according to the functionality specified for your application 4 5 Disconnecting the Meter A Remove main fuse before disconnecting The connecting wires at the place of installation must not be live when remo
33. em A voltage monitor guarantees a safety data storage in the event of a mains voltage failure and a correct start up after the return of the voltage A non volatile memory EEPROM contains the parameter set of the meter and secures the stored measurements against loss due to power failure 1 6 2 Signal Generation The measuring element a DFS Direct Field Sensor registers the phase current with the magnetic field of the current loop and the phase voltage over a resistor divider The analog digital converters transform both signals into digital voltage and current data This data is then multiplied by a digital multiplier to produce an energy proportional value which is then transferred into the energy registers rate dependent The microprocessor generates pulses for the test diode from the digital value according to the meter constant R D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 10 48 Description of Unit 1 6 3 Signal Processing Calibration Start detection Measured quantities Measurement channels Energy registers Rates Rate control 4 quadrant measurement The meter records active and reactive energy and can distinguish between energy import and export in up to 6 rates depending on configuration Calibration data is stored during the final testing of the meter The microprocessor compares the measured power with the minimum starting power The signals are o
34. energy import 3 8 X Reactive energy import rate X X 1 6 4 8 0 Total reactive energy export 4 8 X Reactive energy export rate X X 7 1 6 32 7 0 Line voltage L1 31 7 1 Line current L1 36 7 0 Active energy L1 16 7 0 Total active energy 33 7 Power factor L1 151 7 0 Reactive energy L1 131 7 0 Total reactive energy 14 7 0 Mains frequency 82 8 2 DC field detection counter 82 8 1 Terminal cover removal counter 82 8 3 Disconnector tamper counter C 5 0 Status code see section 5 5 3 C 7 0 Power off counter C 7 1 Phase fail counter L1 0 2 0 Software version 0 2 1 Parameter identification C 2 0 Number of parameterisations 0 2 1 Scheme ID All off Blank display All on All segments on 5 8 0 Reactive Energy Q1 6 8 0 Reactive Energy Q2 7 8 0 Reactive Energy Q3 8 8 0 Reactive Energy Q4 9 8 0 Apparent Energy kVAh Q1 Q4 10 8 0 Apparent Energy kVAh Q2 Q3 15 8 0 Active Energy Absolute Value A Al kWh 16 8 0 Active Energy Absolute Value AJ A kWh 130 8 0 Reactive Energy Absolute Value R R kVArh 131 8 0 Reactive Energy Absolute Value R R kVArh 132 8 0 Reactive Energy Import R Q1 Q4 kVArh 133 8 0 Reactive Energy Export R Q2 Q3 KVArh 36 7 Phase RkW 151 7 Phase R kVar 4 Energy efficiency items see section 5 2 11 Module data 1 12 value and OBIS code will be sent by module End of list Landis Gyr
35. er with communication interface B Meter with communication interface and disconnector Rates e 1 rate d 2 rates t Multirate up to 6 rates Anti tampering No anti tampering F Anti tampering Version s2 Series 2 The e for the 1 rate execution can be skipped in some executions The AMR Module is not part of this type designation since it is a complete unit in itself Users can change it without opening the calibration seal Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Description of Unit 9 48 1 6 Measuring Principle 1 6 1 Overview Inputs Outputs Power supply Memory The main meter inputs are e Phase connection L1 and neutral for energy measurement power supply of the meter PLC communication with communication modules e Display button e Disconnector button only if meter equipped with disconnector The main meter outputs partly also inputs are e LCD to display measured values and the corresponding OBIS code e Optical test outputs red for active or for reactive energy e Optical interface for automatic data readout on site by means of a suitable HHT Hand Held Terminal also input e Secured AMR Interface for automatic data readout through an AMR module e g E35C module with a PLC GSM GPRS Ethernet or other medium also input The supply voltage for the meter electronics is taken from the Single phase syst
36. essed for a time between 0 and 30 minutes default 30 minutes determined by parameterisation DI u iu e This mode is used for accelerated product certification which can now be done with 0 5 kW in about 2 minutes It is indicated by a flashing decimal point 7 1 2 Measuring Times ZCF U 230 V For technical reasons higher measuring deviations can occur during short term measurements It is therefore recommended to use sufficiently long measuring times in order to achieve the required accuracy Table of required measuring times Current A Measuring uncertainty 0 2 Measuring uncertainty 0 1 coso 1 cosp 1 Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Maintenance 43 48 7 1 3 Optical Test Outputs The red test diode is positioned on the face plate It supplies pulses with a value of 1 Wh of the import or export energy measured This corresponds to a meter constant of 1 000 imp kWh For meter testing purposes only the rising edge is decisive 7 1 4 Connection to a Meter Testing Device To test the meter connect it to a dedicated testing device The meter uses a voltage jumper whereby a spring contact connects the voltage circuit of the meter to the phase terminal By inserting a contact pin of 2 5 mm diameter the voltage and current circuits of the meter are sepa rated and the test voltage is connected via the contact pin See Fig 7 1 Current Loop T
37. f the fault the meter should be disconnected removed and sent to the responsible Landis Gyr service centre according to section 6 3 Repairing Meters There are two kinds of errors persistent and transient errors Transient error codes are automatically reset at the next readout The errors can also be cleared either using the formatted write command C150 or by power cycling the meter D Note The formatted write command C150 only clears the error flags in the error register it does not eliminate the error Persistent error codes cannot be reset in the field If the reason for the error persists for example in the case of a component failure power cycling will not clear the error A meter showing a persistent error code must be consid ered unsafe for further use Contact a Landis Gyr Service Centre for sup port 6 2 1 Structure of an Error Code An error code is an eight digit value Each digit of the error code represents four errors i e four bits of the error register The status of the four bits is shown in hexadecimal code i e the single digits may show values between 0 no error code set and F all four error codes set D Error codes are added As all errors are shown in hexadecimal code a single error can appear in various ways depending on the presence of other errors D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 40 48 Service 6 2 2 Error Code
38. g surface provided D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 20 48 Installation De installation 4 2 Connecting the Meter A Remove main fuse before connecting The connecting wires at the place of installation must not be live when fit ting the meter Touching live parts is dangerous to life Remove the corres ponding main fuse and keep it in a safe place until work is completed so that it cannot be replaced by anyone unnoticed A Provide overcurrent protection For ZCF100xB meters As the disconnector is not equipped with a thermal and or short circuit protection device it needs to be protected with an exter nal fuse or overload switch For ZCF100xC meters As the meter has no internal overcurrent protection and no method of disconnection from the mains this must be provided by the end installation Connecting the phase and neutral connection line 1 Shorten the phase and neutral connecting wire to the required length and then strip them 2 Insert the phase and neutral connecting wire into the corresponding terminals the terminals are numbered as shown in the connection diagram and tighten the terminal screws firmly max torque 3 Nm It is recommended to identify the beginning and end of the relevant conduc tors with a suitable test unit e g buzzer to ensure that the right consumer is connected to the meter output Fig 4 3 Meter connections
39. ion indicators are off L 20 UL tt 7 1 6 Starting Test Procedure 1 Apply a load current of 0 1 of the base current I or for MID meters of the reference current l e e g 10 mA with I 1 10 A and the vol tage Un The meter must remain in creep Hu LI IL L mow kW h Lv e Gel 2 Increase the load current to 0 5 I for MID to 0 5 let i e 50 mA with Ip ke 10 A The energy direction arrow must appear within 10 seconds and both anti creep indications must disappear The optical test output for active energy must start to flash A 7 2 Cleaning A Danger of short circuits Never clean soiled meters under running water or with high pressure devices Water penetration can cause short circuits To remove normal dirt like dust a damp cloth is sufficient If the meter is heavily soiled it should be dismantled if necessary and sent to an authorised service centre so that a new plastic viewing window can be fitted Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Decommissioning Disposal 45 48 8 Decommissioning Disposal This section explains the disconnection of the meter from the system and its correct disposal 8 1 Decommissioning The procedure for disconnecting and removing the meter from the mains is described in section 4 5 8 2 Disposal Based on the data specified in environmental certificate ISO 14001 the compo
40. ited Kingdom Ltd NB0120 Systems amp Services Certification 202B Worle Parkway Weston super Mare BS22 6WA UK Northfields VASA Bont A Am 18 Mar 2010 Neil Bennett Head of R amp D Kevin Rayner Quality amp Process Manager E Residential EMEA This explanation and the associated documents are deposited Cette explication et les documents correspondants sont d pos s Bob Cox Landis Gyr Diese Erkl rung und die zugeh rigen Unterlagen sind hinterlegt bei EXT075 2 c de en fr Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Annex Declaration of Conformity 47 48 D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr Contact Landis Gyr Europe AG Theilerstrasse 1 CH 6301 Zug Switzerland Phone 41 41 935 6000 Langis www landisgyr com manage energy better
41. l description of the E350 Meter service Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Safety 13 48 2 Safety This section describes the safety information used in this manual outlines the responsibilities and lists the safety instructions to be observed 2 1 Safety Information Attention is drawn to dangers and their level severity and probability in this user manual in the following way A Definition of Danger For a possibly dangerous situation which could result in severe physical injury or fatality A Definition of Warning For a possibly dangerous situation which could result in minor physical injury or material damage Definition of Note For general details and other useful information to simplify work All safety information also describes the type and source of the danger its possible consequences and measures to counteract the danger 2 2 Responsibilities The owner of the meters is responsible that all persons engaged on work with meters 1 Are competent and qualified in accordance with national regulations see ISSA Guideline for Assessing the Competence of Electrically Skilled Persons Have read and understood the relevant sections of the user manual Strictly observe the safety instructions according to section 2 3 and the operating information in the individual sections In particular the owner of the meters bears responsibility
42. l through to the end of the recall list then End is displayed after which auto scrolling is resumed A long press more than 5 seconds in the main display will access the service display Exception If the display button is pressed long while the consumption since last reset is displayed the register is reset instead The following table shows a simple meter normal display sequence con figuration The value of the total active energy import register is assumed to be 000123456 Wh and that of the total reactive energy import register 000009876 Varh The registers are set to show 6 digits with 1 decimal place The leading zeros are not suppressed Displayed value Total active energy import Total reactive energy import Display check all segments on Empty display all segments off D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 30 48 Operation nn 3435 The meter first shows the total LIL th tt active energy import register as Hatt a kW h 00123 4 kWh followed by the reactive energy import register as Ex nnnm l 00009 6 kvarh and all segments on Hur AL and then all off The display dura II k Varh tion for each display can be set AA m between 1 and 10 seconds but not erre H H H HH HH H MJ individually This sequence is re JR DIE ER LS Gs DOMNH VAKWarh peated until the meter is switched S X CHO yw ow wv vy off or the recall list sho
43. ndicator Phase voltage indication Arrow symbols Indicates in which quadrant the present measurement is made An 1 quadrant T 3 quadrant P a Q nd th P A 2 quadrant wt 4 quadrant The reactive anti creep indication a diamond shows that the kvarh regis ters have entered anti creep mode No energy is flowing through the meter no reactive energy direction indicator displayed The active anti creep indication a circle shows that the kWh registers have entered anti creep mode No energy is flowing through the meter no active energy direction indicator displayed The media icons represent the medium measured from left to right water gas heating and electricity The media icon displayed corresponds to group A of the OBIS identification code see also section 5 2 3 The electricity media icon is either on if data from the internal meter is dis played or is flashing if data from an external meter is displayed automati cally controlled The water gas and heating media icons are also flashing if data from an external source is displayed This icon indicates that the respective media represented by the displayed media icon is disconnected by the disconnector Icon ON Disconnector open circuit interrupted Icon OFF Disconnector closed circuit closed current can flow Icon flashing Disconnector open can be closed locally Push Button This operation is the preset The operation
44. nennn AERE MEERE 6 1 3 Field of Appltcaton nenn 7 1 4 Characteristics un nee 7 1 5 Type Designation aussi en ne kehren 8 1 6 Measu ring del 9 t Zo Mt e e 9 E E E EE 9 1 03 2ignalPioeessnig ce a E O T aS 10 1 7 Instantaneous Values nemen nemen nennen nennen nennen n nenne se enses 11 1 8 Anti Tampering and Tamper Prevention eee 11 1 97 Peenaeen cT 11 1 10 Software Tools rt e nenn 12 De see 13 2 1 Safety NON AMO SE 13 ee Ee UE 13 2 3 Safety le e TL TEE 14 2 4 Radio Interference nn 14 3 _Mecha nical Description us 34004400044 oe erre reto naeh nam e Ene an nennen nenne nee 15 SN WR ee EE 15 3 2 FACS Plate ee detinere rnm ra SEENEN eege REENEN 16 3 3 Connection Diagrams Samples szene ale 16 3 4 Dimensions HIHI EGRE ace Dre DR Duo ERIT OR LEER TETUR 17 4 Installation De installation nn an nri erae rir nn 19 4 1 e aie th EE 19 4 2 Connecting the C et TTE 20 43 Checking the Connections e 21 4 4 Commissioning and Functional Check 22 4 5 Disconnecting the Meter occisi eeclesiae eA bep iiie ie caasa ipu ipee ecd tablets 22 Ben TU e a 23 5 1 Control Elements EE 23 5 1 1 Display Button RR 23 5 1 2 Disconnector Button 23 32 Lui Crystal Display E RG 24 5 2 1 BASIC Layout EE 24 5 2 2 Explanation of LCD Elements 24 5 2 3 Displaying OBIS Codes nennen nennen nn nn 26 9 24 Display
45. nents used in meters are largely separable and can therefore be taken to the relevant disposal or recycling point Disposal and environmental protection regulations For the disposal of meters observe the local disposal and environmental protection regulations in effect without fail Printed circuit boards Electronic waste disposal according to local regulations Plastic components Sorted and taken to recycling regranulation plant or if no other possibility to refuse incineration Metal parts Sorted and taken to collective materials disposal point D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 46 48 Annex Declaration of Conformity 9 Annex Declaration of Conformity AN Declaration of conformity Landis x D claration de conformit G rT C y Konformit tserkl rung Kak EXTO75 2 We Landis Gyr Limited Nous 1 Lysander Drive Wir Northfields Industrial Estate Market Deeping Peterborough PE6 8FB United Kingdom declare under our sole responsibility that the products d clarons sous notre seule responsabilit que les produits Product Name E350 erkl ren in alleiniger Verantwortung dass die Produkte e Single phase static meter Class index B ZCF110A s2 Compteur statique monophase Genauigkeitsklasse B ZCF110C s2 Statischer Einphasenz hler Class index A ZCF120A s2 Genauigkeitsklasse A ZCF120C s2 to which this declaration relate
46. nication request only under either of the following conditions Ifthe request contains no address If the address matches with the address of the meter The address of the meter is preset to the serial number of the meter For SW versions prior to M52 the meters reacts only if the request contains no address If the meter is connected to a communication bus with several meters the communication request must be started with address Otherwise a communication conflict between the meters will occur Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Service 39 48 6 Service 6 1 Operating Faults If the LCD is not readable or the data readout does not work the following points should be checked first 1 Is the mains voltage present main fuse intact 2 Is the maximum permissible ambient temperature not exceeded 3 Is the optical interface and or the liquid crystal display clean not scratched painted over misted over or soiled in any way Danger of short circuits Never clean soiled meters under running water or with high pressure devices Water penetration can cause short circuits To remove normal dirt like dust a damp cloth is sufficient If the meter is heavily soiled it should be dismantled if necessary and sent to an authorised service centre so that a new plastic viewing window can be fitted 6 2 Error Codes If none of the points listed is the cause o
47. nly passed on if the minimum starting power is exceeded The following energy values can be measured and stored in the registers e Active energy A e Reactive energy R e Apparent energy S A and R are the imported measured active and reactive energy A and R the exported measured active and reactive energy The combined values are the sum or the difference of the absolute values of A and A or R and R The measurement of single quadrants can be configured too Energy type kWh kvarh or kVAh Direction Import export reactive Instantaneous Values Voltage current frequency power factor There are 8 independent measurement channels One of the measured quantities can be assigned to each of this register The measurement channels 1 to 6 have 6 rated registers and 1 total each channel 7 and 8 have only 1 total register 44 registers are therefore avail able in total All registers work internally with 9 digits The internal valence is Wh Watt Hours They cannot be reset At 999999999 a rollover to 0 takes place The display and readout formats vary from the internal format The meter is designed for up to 6 rates The assignment of the rate regis ters is done by means of parameterisation and is shown on the face plate Rate control is performed by the external module With up to 2 rates the rate switching is operated by the AMR Module directly or by control inputs The rate switching for more than 2 rates
48. rt press of the display button or the service display long press of the display button is entered 5 2 6 Display Check During the display check all segments of the display are on Especially the index and value fields should be checked for missing segments 3 Q u QUEPQ SE lt lt uN e se DUDU DD DLL S lg UUUUDUDULDDe LI M DIDI 2s eL VA kWarh AONO vov v v v Ki 5 2 7 Error Display An error display can be included in a display sequence but it also automati cally turns up in case of a malfunction The error code is based on a 32 bit value in which each bit if set indicates a particular error condition In the following error display the error code 00002002 is composed of the two errors 00000002 and 00002000 ce 1 IT d The error codes are described in section 6 2 2 Error Code Descriptions 5 2 8 Text Messages on Display It is possible for the module to show information on the meter display Pos sible items include Ids of connected devices time For this the value and the index fields can be used This information is available in the module documentation Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Operation 31 48 The following characters can be used in text messages Character LCD Character LCD Character LCD lt SPACE gt A A N n
49. s is in conformity with the requirements of the following directives auxquels se r f rent cette d claration sont conformes aux prescriptions des directives auf die sich diese Erkl rung bezieht konform sind mit den Anforderungen der Richtlinien e 2004 22 EC Measuring Instruments Directive MID e 2004 22 EG Europ ische Messgeraterichtlinie MID The conformity was assessed in accordance with MID Module B D and the following harmonised EN standards La conformit f t contr l selon MID Module B D et les normes EN harmonis es Die Konformit t wurde berpr ft anhand MID Module B D und der harmonisierten EN Normen e EN 50470 1 2006 Electricity metering equipment a c General requirements tests and test conditions Metering equipment class indexes A Band C e EN 50470 3 2006 Electricity metering equipment a c Particular requirements Static meters for active energy class indexes A B and C Number of EC type examination certificate Notified Body Num ro du certificat de lexamination type EC Organisme notifi Nummer der EG Baumusterpr fbescheinigung Benannte Stelle e T10244 NMi Certin B V NB0122 Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands Number of quality system approval certificate Notified Body Num ro du certificat d approbation du system de Qualit Organisme notifi Nummer des Zertifikates ber die Anerkennung des Qualit tsmanagementssystems Benannte Stelle e GB07 72954 SGS Un
50. sented with the media icons A TEE vv L V 14 B Group B is not shown on E350 meters only channel 1 available C Defines the measured quantity the abstract or physical data items re lated to the information source concerned e g active power reactive power apparent power power factor current or voltage D Defines types or the result of the processing of physical quantities according to various algorithms The algorithms can deliver energy and demand quantities as well as other physical quantities E Defines the rates in use For abstract data or for measurement results without rates this value group can be used for further classification F Group F is not shown on E350 meters OBIS identification code 1 1 31 7 1 0 line current in phase L1 is repre sented as follows on the display Group A of the OBIS identification code is represented by the media icon for electricity groups B and F are not displayed and groups C to E are represented as index value 31 7 1 The line current in phase L1 is indicated with 25 24 A The active energy direction arrow P the phase voltage indication L1 and the arrow symbol of the current rate are also displayed 5 2 4 Display Definitions D The meter can show various displays Here are some examples Note The number of digits and decimal places displayed can be parameterised also whether leading zeros are to be displayed The following e
51. t lt module communication The module communicates normally via dims Access to module over optical port of meter is possible with Xxxxxxxx1 214 where xxxxxxxx is the meter number Opening 7214 7 bit even parity 1 stop bit 4800 bps This can be used to read out the module over the optical meter interface or to set the TOU table of the module Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Operation 35 48 5 5 Data Readout The power supplier can read the meter data particularly the energy con sumption locally in two ways e Reading the meter s LCD Only the data shown in the display list can be recorded e Automatic data readout via the optical interface with the aid of an AMR Module e g hand held terminal T3000 Further data are then acces sible depending on the parameterisation total registers etc Log cor responds to the provisions of IEC62056 21 a communication standard for meters 5 5 4 IEC 62056 21 Mode C The meter supports IEC 62056 21 mode C a This enables the reading of data from the meter in the data readout mode After an initial sign on se quence the meter transmits its data to the HHT This consists of a number of items which are set in the configuration Each item is sent in ASCII with OBIS IEC 62056 61 identifiers Each identifier is on a separate line sepa rated by carriage return and line feed characters orl and follows the for mat
52. ted Not used Error restoring energy registers Data saved to EEPROM on power fail is corrupted Not used NIDIA AeIOIN gt Oo Valid for readout with E35C modules For other modules other codes could be delivered e g equal to error display values D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Landis Gyr 36 48 Operation 5 5 3 Readout Status Code C 5 0 The E350 devices feature along with universal device status symbol showed on display also a status register which shows the current status of the device The readout status register C 5 0 consists of 16 bits 2 bytes and describes the following Bit number Allocation 0 Reverse export detect cleared after readout 1 Creep flag set on product initialization and cleared when meter first registers energy 2 L1 phase fail flag 3 L2 phase fail flag 4 L3 phase fail flag 5to7 Active rate coded bit7 bit6 bit 5 active rate 0 0 0 rate 1 0 0 1 rate 2 0 1 0 rate 3 0 1 1 rate 4 1 0 0 rate 5 1 0 1 rate 6 8 Strong magnetic DC field detected 9 Terminal cover removed 10 Disconnector state 0 open 1 closed 11 Disconnector tamper detected 12 to 15 reserved The bits 8 9 and 11 will be set as soon as a tamper event was registered The bits will be reset only at power down if configured or by a reset signal over the optical or AMR interface
53. vice cessere nennen 43 FAD Creep T6st ecc n nenne een 44 A Voe 11 UII e 44 T2 a io EE mmm 44 8 Decommissioning Disposal 2 enne annu nau DE n Ruanda cR xER a EERER anna han 45 8 1 DECOMMISSIONING TR o o I E 45 8 2 Dteppoesal E 45 9 Annex Declaration of Conformity nano anne 46 Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Description of Unit 5 48 Introduction Range of validity Purpose Target group Reference documents The present manual applies to the following meter versions Single phase Two wire network e ZCF100AC and ZCF100AB for active energy import and export e ZCF100CC and ZCF100CB for active and reactive energy import and export For a detailed explanation of the type designation see section 1 5 The user manual contains all information required for meter applications for the intended purpose This includes e Provision of knowledge concerning characteristics construction and knowledge of meters e Information regarding possible dangers their consequences and measures to prevent any danger e Details concerning the performance of all work throughout the service life of the meters parameterisation installation commissioning opera tion maintenance shutting down and disposal The content of this user manual is intended for technically qualified person
54. ving the meter Touching live parts is dangerous to life The corres ponding main fuse should be removed and kept in a safe place until work is completed so that it cannot be replaced by anyone unnoticed IN For ZCF100xB Do not use the disconnector as a main switch for disconnecting purposes The meter remains connected to the mains Remove the meter from the network as follows 1 Switch off the voltage The display goes off 2 Remove the seal at the terminal cover 3 Release and remove the terminal cover 4 Ensure with a phase checker that the connecting wire has no voltage If there is voltage remove the main fuse gn Remove the connecting wires of the AMR Module if available 6 Loosen the terminal screws of the phase and neutral connecting wire with a suitable screwdriver and withdraw the wires from the terminals 7 Fita substitute meter as described in section 4 2 Connecting the Meter and the following sections if necessary Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Operation 23 48 5 Operation 5 1 Control Elements E350 meters have a display button on the front cover and a disconnector button on the terminal cover ifthe meter is equipped with a disconnector Data acquisition is either made by reading the display or automatic readout via the optical interface For this purpose the optical head is placed on the marked position on the front cover ofthe meter
55. xamples show different settings Landis Gyr D000030875 EN n E350 series 2 1 phase ZCF100Ax Cx User Manual Operation 27 48 Total active energy import Mains frequency gs pur Q p r t UI fe du Ex LUC OG Lint th ot tt UM u kW h II 6 LOU v Ul UU e Total reactive energy import Status code p ur Q p wr ks nnnn ol Ex r1 LILILILI 0 Ltt Ann u k Varh rem oo D v LIL v Active energy import rate 1 Phase fail counter Q gu Cu gt u vm Q NMII1 TIT A L1 LLDIE ICI L i I u kW h 11 rp b i v Lie v Active energy export rate 2 Manufacturer identification number t nu roc Ex quay gt LU L I n E a i i AL CI IU IC tia 3n j 1 ret D DC P En Ed by Line voltage Water consumption OD 2632 RUN Heat consumption Fo Ex epey 0015643 bi 5 E Total power factor Gas consumption e nra ad m _ UOC 5 anc RE e 5 2 5 Display Sequence The previous section showed in detail the possible displays The display sequences shown on any specific customer s product are set through para meterisation at the factory There are two display sequences e Main display with an auto scrolling list and a recall list e Service display with the service list The main display can include up to 31 displays the service display up to 63 displays defined by parameterisation The p