iRT 30 - Buderus
Contents
1. Do not connect the wires to connection points in the boiler other than points 3 and 4 This can cause damage to the boiler or the thermostat lt COANDURWN M figure 5 6 6 Fix the thermostat onto the mounting plate o Place the thermostat onto the mounting plate refer to figure 5 7 a I Hook the thermostat from the top onto the mounting plate 2 Push the bottom side of the thermostat towards the wall until the thermostat clicks onto the mounting plate figure 5 7 24 English Installation of the IRT 30 5 2 Testing the thermostat Switch on the power supply of the boiler The thermostat automatically completes a start up and test program First the display is empty During 3 seconds all symbols will be shown on the display also refer to figure 3 1 Subsequently the version number of the software will be shown on the display After this a few tests will be executed During the first tests EE will be shown on the display If this test is successful a will be shown left in the display changing into a 2 After this the communication with the boiler will be tested If this test is succesful a I is shown in the display At the end the thermostat itself will be tested If this test is successful a is shown in the display After the test the day number and the time indication are blinking in the
2. 12 English If the thermostat is set to weather dependent regulation and you turn the temperature adjustment knob out of the AUTO mode the thermostat will function as for weather dependent regulation with room temperature compensation On the screen the symbol of weather dependent regulation will be replaced by the symbol for weather dependent regulation with room temperature compensation also refer to page 9 4 3 Setting the clock For a correct functioning of the clock program it is important that the set time is equal to the actual time Setting the clock is only possible when the display is in normal mode I Make sure the display is in normal mode refer to figure 3 2 Wait 7 seconds until the display returns to the normal mode if the display is not in normal mode for example because you are programming 2 Set the correct day Press and hold the DAY key Change the day number using the program knob Monday Tuesday 2 etc Release the DAY key J i ca N E Tu U M AN P N 3 Set the correct time Press and hold the TIME key Change the time using the program knob Release the TIME key m 2 1 ci J THE SS 4 4 Clock programs With the clock programs the IRT 30 can regulate the temperature automatically throughout the week The clock program uses switching points The program will switch over to your tempe
3. figure 3 2 Display in rest 4 Operation 4 1 General Read this manual carefully so you can operate the IRT 30 correctly Your installer can inform you in detail about the use of the clock thermostat Efficient heating and ventilation Avoid extreme temperature settings and quick changes of temperature in the program difference between day and night temperature may not exceed 5 C Do not let the temperature of the rooms drop too low during night setting Your CH must burn longer and more intensely to heat up walls which are cooled down Make sure your house has a good atmospheric humidity especially during the cold months You can achieve this by placing indoor plants or humidifiers A good atmospheric humidity contributes to a pleasant climate in your house Ventilate well briefly more ventilation takes less energy than ventilating a little for a long period Clock Set the clock of the IRT 30 to the correct time if necessary to ensure correct functioning of the clock thermostat refer to paragraph 4 3 Setting the clock Operation Power supply The IRT 30 does not use batteries but uses electric power The necessary electric power is supplied via a connection on the boiler During power failure or when switching off the power supply the clock will continue for at least one hour Your clock program will always be maintained Maintenance Clean the IRT 30 using a dry cloth Do not us
4. By means of this principle of control hot CH water is available nearly all the time If in another room a closed radiator valve is opened the room will quickly be brought up to temperature as a result When to apply the room temperature controlled regulation When the house is heated only by means of radiators When not to apply the room temperature controlled regulation When there is no appropriate reference room in the house to install the IRT 30 When your house is heated also by means of floor heating air heating or convectors In practice the room temperature controlled regulation is the principle which will be selected in most cases Weather dependent regulation This is a principle of regulation in which the determination of the CH water temperature is achieved by the outside temperature and a number of preset values in the IRT 30 This can be necessary when no reference room is available Furthermore this principle is used in buildings where it must be possible to heat the rooms independently from each other for example old people s homes or office blocks For this principle the separate rooms should be equipped with radiators with thermostatic radiator valves in order to regulate the temperature in each room English 5 6 English In a house which is heated by floor heating the temperature fluctuations should not become too large Furthermore this kind of heating heats up and cools down very slowly
5. Programmable roomthermostat Instruction manual e Gv o o do m 00 e oo 10 temperature adjustment knob Temperaturwahlschalter bouton de r glage de la temp rature manopola di regolazione della temperatura Temperatur indstillingsknap temporarily reduce the program temperature Programmtemperatur vor bergehend erniedrigen abaisser temporairement la temp rature du programme riduzione temporanea della temperatura programmata Midlertidig s nkning af programtemperatur temporarily raise the program temperature Programmtemperatur vor bergehend erh hen augmenter temporairement la temp rature du programme aumento temporaneo della temperatura programmata Midlertidig forogelse af programtemperatur adjustable program knob Programmwahlschalter bouton de r glage du programme tasto di programmazione Programdrejeknap day Tag jour giorno Dag time Zeit Heure ora Tid temperature Temperatur temp rature temperatura Temperatur vacation Urlaub vacances vacanze Ferie insert Einf gen ins rer inserire Indforing remove L schen effacer Slet heating Heizung chauffage riscaldamento Opvarmning hot water Brauchwasser eau chaude acqua calda Varmt vand menu Men menu menu Menu Technical specifications EV number EV number optional outside sensor Power supply Maximum wire thickness Permissi
6. D s um ae e SS 1 U RUM 2 Hold the INSERT key and release the other keys 3 Turn the program knob while holding the INSERT key until the desired PID number appears in the display 4 Release the INSERT key 2 Adjust the clock speed The IRT 30 thermostat has a internal clock This clock can lose or gain some time in the long term You can adjust the speed of the clock When you enter a correction of 1 the clock will run minute per year faster You can adjust the clock as follows I Simultaneously press the MENU INSERT and REMOVE key and release them 2 Press an hold the INSERT key again On the display corr appears NI r 11 gt V 3 Turn the program knob while holding the INSERT key until the desired clock correction appears 4 Release the INSERT key 3 Switching the slow temperature rise on or off If you have a boiler with a high capacity this can cause the CH water to heat up too fast This can result in a ticking sound in the tubes To prevent this you can set the slow temperature rise to on Configuration and calibration of the IRT 30 thermostat You can switch the slow temperature rise on or off as follows I Simultaneously press the INSERT REMOVE and MENU key and release them 2 Press the INSERT key twice again an hold it On the display SLO or FASt appears m Wy m ucl rt w
7. In this situation weather dependent regulation is a good choice because with this regulation the heating intensity of the boiler will only be affected by the outside temperature Because of this changes will take place relatively gradually What does the weather dependent regulation mean The heating intensity of the boiler is determined by the outside temperature and specific preset values on the IRT 30 clock thermostat When the outside temperature drops the boiler will burn more intensely and heat the CH water to a higher temperature up to a preset maximum temperature When the outside temperature rises the boiler will burn less intensely and heat the CH water to a lower temperature up to a preset minimum temperature The rooms will be heated by the continuously circulating CH water The temperature in the rooms to be heated can be regulated by means of thermostatic radiator valves When to apply weather dependent regulation When your house does not have a suitable reference room When you want to precisely regulate the temperature in more than one room When not to apply weather dependent regulation When your house does not comply with the above mentioned criteria This is a relatively less economical regulation principle so you should apply this kind of regulation only if strictly necessary Weather dependent regulation with room temperature compensation This kind of regulation is a derivative of the
8. Setting the clock 12 Setting the clock program 14 Setting the temperature Slow temperature rise 33 Switching point 3 14 42 Temperature control 11 25 Testing the thermostat 24 Thermostatic radiator valves 5 Vacation setting 18 Ventilate 10 Weather dependent regulation 5 42 Weather dependent regulation with room temperature compensation 44 English 45 Settings of the IRT 30 Min Max settings Standard setting Your settings by installer CV menu refer to paragraph 6 2 ECO temperature 10 25 16 C Advanced heat up YES NO YES Kind of temperatur regelation RR WD WD RTC RR Installation type 1 2 3 4 N A N A Starting point of the firing characteristic 10 90 Endpoint of the firing characteristic 10 90 Refer to Table A Room influence 0 10 Minimum CH water temperature 10 C Hot water menu refer to paragraph 7 2 Advanced heat water heat up 0 120 30 min Hot water stop delay 0 120 30 min Configuration settings refer to paragraph 8 1 PID number 1 213 l Correction of the clock speed 99 99 0 Slow temperature rise SLO FAST FAST Other settings refer to paragraph 4 6 Hot water ON OFF AUTO ON Heating ON OFF AUTO ON Standard clock refer to paragraph 4 5 RR WD RTC WD Monday to Friday 7 00 21 C 9 00 19 C I 17 00 21 C 23 00 ECO 4 Saturday and Sunday 8 00 21 C 23 00 ECO 4 TableA Standard settings for differ
9. Have you replaced an old geyser by a combi boiler A combi boiler can produce more hot water more comfort but also uses more energy Is the ECO setting too high as a result of which the room temperature is too high during the night Only WD and WD RTC Are the values for the starting point and end point set in the CV menu not set too high The display shows an incorrect temperature Is the IRT 30 thermostat able to determine the correct temperature Is the thermostat installed on a cold or warm wall Is it installed in direct sunlight or in draught Is the IRT 30 thermostat installed near an open window or near heat sources tv refrigerator or lamps If you are convinced that the indication of the temperature is incorrect most of the times it is correct the temperature measurement can be calibrated refer to chapter 8 Outside temperature indication is incorrect only for WD and WD RTC display shows on the position of the temperature indication Is the outside temperature sensor able to determine the correct outside temperature Installed on a warm or cold spot on the outside wall influenced by sun wind snow ice or rain Has the correct wiring preferably 0 75 mm2 been used Does the wiring run along a 230 V power supply cable Is the wiring connected to terminal 7 and 8 of the terminal block in the boiler If necessary the outside temperature sensor can be calibrated refer to chapter 8 Malfunctions a
10. In this menu you can I Change the heat up speed setting PID 2 Adjust the clock speed 3 Switching the slow temperature rise on or off 4 Reset the thermostat The configuration menu appears in the display when you first press and hold the MENU key and the INSERT key and after that press and hold the REMOVE key You now press and hold 3 keys at the same time You can scroll through the configuration menu by pressing only the INSERT key I Change the heat up speed PID setting If the thermostat is set to room temperature controlled regulation you can adapt the heat up speed of the CH installation This is necessary if the temperature in the room where the thermostat is fitted during heat up rises to a higher temperature then the set temperature and then drops to the set temperature There are 3 possible settings PID I This is the standard and also the fastest setting This setting satisfies almost all of the cases PID 2 This is a slower setting This setting is intended for a fast house that means a CH installation with a large boiler and radiators with a large surface PID 3 This is the slowest setting This setting is meant for very fast houses Configuration and calibration of the IRT 30 thermostat English 33 amp Q9 34 English You can adapt the heat up speed as follows I Simultaneously press the MENU INSERT and REMOVE key PID appears on the display
11. Set weather dependent regulation 3 Select the correct installation type 4 Leave the CH menu 5 Wait for 3 or 4 hours 60 C 45 C4 CH water temperature 30 C4 JSC tu ette eT end point starting point T T 20C IC cC I0C outside temperature Firing characteristic The firing characteristic is a line which shows the temperature of the CH water at a certain outside temperature You can set the firing characteristic with the help of 2 points the desired water temperature at 20 C outside temperature starting point the desired water temperature at 10 C outside temperature end point 26 English Setting the temperature control CH water temperature s a i i i i i i i i f i T T T T 20C UC OC 10C outside temperature CH water temperature T T T T 20C UC OC 10C outside temperature CH water temperature u A y 8 8 a P paR T T T T 20C 10 C cc I0C outside temperature Setting the temperature control 6 Check the temperature in the coldest room 7 Set the firing characteristic using the CH menu when the temperature in the coldest room is too cold or too warm refer to paragraph 6 2 For example if it is too cold or too warm in a room during winter the firing characteristic can be adjusted according to the following diagram Outside temperature is less then 0 C Warmer Colder raise th
12. display 1 I na DOR Uh a Set the day number and the time to the correct value refer to chapter 4 5 3 Setting the thermostat Before you start using the IRT 30 thermostat a few settings should be checked and if necessary changed I Set the correct kind of temperature control refer to chapter 6 2 Check the settings of the hot water supply and change them when necessary refer to chapter 7 3 Change the installation parameters of the thermostat if necessary refer to chapter 8 Installation of the IRT 30 English 25 6 Setting the temperature control 6 1 Selecting a temperature control The IRT 30 thermostat is suitable for 3 kinds of temperature control Room temperature controlled regulation RR Weather dependent regulation WD Weather dependent regulation with room temperature compensation WD RTC Select one of these control before you continue Chapter 3 describes the points of attention for making your choice You have selected room temperature controlled regulation RR Set the thermostat as follows I Go the CH menu refer to paragraph 6 2 2 Set room temperature controlled regulation 3 Leave the CH menu 4 Continue with setting the hot water supply refer to chapter 7 You have selected weather dependent regulation WD or WD RTC Set the thermostat as follows I Go the CH menu refer to paragraph 6 2 i Only change the settings mentioned below 2
13. hold the HEATING key The display shows the current boiler mode 0 z on off Standard setting is on 1 English 19 3 Turn the program knob to change the setting The boiler mode will change from on to off or the other way round w 4 Release the HEATING key The display will show the current display code of the boiler for 3 seconds e If your thermostat is set to weather dependent regulation with or without room temperature compensation I Make sure the display is in normal mode refer to figure 3 2 2 Press and hold the HEATING key The display shows the current boiler mode M on W off Standard setting is on A 3 Turn the program knob to change the setting On the display the symbol of your control appears next to the radiator On the right side in the display a number appears which may vary from 10 to 25 With this number you can set the outside temperature at which the CH installation has to switch off automatically When you turn the program knob to 25 the next setting is off M 4 Release the HEATING key The display will show the current display code of the boiler for 3 seconds was 20 English Operation Hot water If your boiler is also equipped with a hot water supply or controls one this hot water supply can be set to the ON OFF or AUTO mode as desired I Make sure the display is i
14. weather dependent regulation With this principle the CH water temperature is determined in first instance by the outside temperature and the preset values on the IRT 30 However the thermostat also measures the temperature in the room where it is fitted Brief description of the IRT 30 Brief description of the IRT 30 This information is used to make minor corrections to the signal to the boiler so that the desired temperature can be reached The temperature in the room where the thermostat is fitted is determined by the thermostat itself The temperature in all other rooms can be regulated by means of the thermostatic radiator valves Basically you can choose this kind of regulation in the same cases as you would choose the weather dependent regulation without room temperature compensation A suitable reference room should be available in the house What does weather dependent regulation with room temperature compensation mean The CH water temperature will be determined in first instance by the outside temperature and the preset values in the IRT 30 The IRT 30 also measures the temperature in the room where it is fitted On the basis of the measured room temperature the IRT 30 adapts the water temperature of the CH automatically The rooms will be heated by the continuously circulating water The temperature in the room where the thermostat is fitted will be determined by the thermostat itself The temperatur
15. 4 If the rooms have been equipped with too many or too large radiators the house can also be heated with water of a lower temperature The maximum temperature setting of the water can be reduced on the UBA In the morning heating up takes too long I Set the advanced heat up to on only for RR and WD RTC 2 Advance the switching point to give the installation more time to heat up the house 3 We advise not to let the difference between the day and night temperature exceed 5 C for floor heating we advise a maximum difference of 2 C Malfunctions and the display codes of the boiler At the beginning of the day the installation is heated up too far too long The rooms become too warm I Lower the temperature in the clock program for the switching point of the beginning of the day 2 Raise the PID setting so that the installation will burn less intensely 3 If the capacity of the boiler is much higher then necessary the water will be heated up too fast By means of the partial load potentiometer on the UBA the maximum capacity for heating up the water can be reduced so that the water will be heated up more slowly 4 If the rooms have been equipped with too many or too large radiators the house can also be heated with water of a lower temperature The maximum temperature setting of the water can be reduced on the UBA The room becomes too warm warmer then the set temperature I Is the IRT 30 thermost
16. ail In doing so you can refine the temperature regulation of your home The IRT 30 is suitable for three kinds of temperature regulation room temperature controlled regulation weather dependent regulation weather dependent regulation with room temperature compensation The kind of temperature control which is applicable to you is the starting point for setting the IRT 30 Therefore the following paragraphs will describe the three kinds of temperature regulations English 3 4 English 3 2 Selecting the correct kind of temperature regulation In paragraph 3 1 the three kinds of temperature regulation for which the IRT 30 is suitable are mentioned room temperature controlled regulation weather dependent regulation weather dependent regulation with room temperature compensation For the last two mentioned it is necessary to place an outside temperature sensor which determines the outside temperature and sends this information to the boiler on the outside wall of your house This must be a wall where the sun does not shine on directly and where the outside air can freely circulate around the sensor Room temperature controlled regulation This is the simplest principle of regulation It gives a high comfort level and has a high performance To ensure the installation will operate according these principles a number of conditions should be satisfied There should be a room in your house in wh
17. ake sure the connection wires stick out of the wall for at least 5 cm on the mounting location 5 Hold the mounting plate against the wall and mark the mounting holes on the wall only applicable for mounting directly onto the wall Remove the mounting plate Drill holes 5 mm on the marked positions Place the plugs in the holes ON oy Mount the mounting plates with the screws and washer against the wall Do not fasten the screws too tightly The mounting plate may not deform refer to figure 5 3 If you fix the mounting plate onto a standard terminal box you only need to use the screws and the washers refer to figure 5 4 figure 5 4 Installation of the IRT 30 English 23 5 Connect the wiring A Make sure the power supply of the boiler is switched off I Connect the wires onto the mounting plate by fitting them behind the clamps refer to figure 5 5 It is not important figure 5 5 which wire is connected to which clamp 2 Push the wires back into the hole in the wall if the wires are too long Fill the hole in the wall with filler to prevent draught affecting the operation of the thermostat 3 Make sure the wires are fitted into the slots of the mounting plate and that they do not cross each other 4 Connect the wires to the boiler Connect the wires to con nection point 3 and 4 of the connector refer to figure 5 6 Lj It is not important which wire is connected to point 3 or 4 ez
18. at able to measure the correct temperature only for RR and WD RTC Is the IRT 30 thermostat installed on a cold outside wall or in stream of draught 2 If the rooms have been equipped with too many or too large radiators the house can also be heated with water of a lower temperature The maximum temperature setting of the water can be reduced on the UBA 3 Are the thermostatic radiator valves installed correctly Is cold air streaming around the thermostatic radiator valves It is too cold colder then the set temperature in the room I Is the IRT 30 thermostat able to measure the correct temperature only for RR and WD RTC Is the IRT 30 thermostat installed between cupboards no natural airflow or in the vicinity of heat sources tv refrigerator radiator etc 2 Are the thermostatic radiator valves completely open in the room where the thermostat has been installed 3 Check the setting of the maximum CH water temperature on the UBA 90 C maximum 4 Has the pump switch on the UBA been set to position 2 only for WD and WD RTC Malfunctions and the display codes of the boiler English 39 40 English Energy consumption is too high higher then old boiler the boiler burns too often or too long Is the room heated while it is not in use Insert more switching points with a lower temperature to the clock thermostat Is the capacity of the new boiler higher then the capacity of the old boiler
19. ating you should contact your installer KD TALT cut HIN figure 9 1 Malfunctions and the display codes of the boiler English 41 Other codes Malfunction of the sensors On the display appears the symbol of the mechanic three blinking dashes on the position of the temperature indication the symbol of the room temperature or the symbol of the outside temperature indicating which sensor is malfunctioning refer to figure 9 2 and 9 3 E JU i SPAN Z c curbs V yey Balk s N NE c CAIRA figure 9 3 Outside temperature sensor Malfunction of the communication with the UBA On the display appears the symbol of the mechanic blinking text UbA refer to figure 9 4 figure 9 4 In both cases you should contact your installer 42 English Malfunctions and the display codes of the boiler 10 Glossary Switching point A switching point is a setting in your clock thermostat It is a moment in time at which you desire a different temperature To set this you have to enter the desired time and the desired temperature Reference room A reference room is a room for example the living room where a temperature can be measured which is representative for the entire house We assume that the temperature in other rooms for example kitchen or bedroom is equal to the temperature in the reference room A room where the temperature is not represent
20. ation of the IRT 30 thermostat 8 1 Adapting the configuration 8 2 Calibration Malfunctions and the display codes of the boiler 9 1 Malfunctions 9 2 Display codes of the boiler Glossary Index Technical specifications Settings of the IRT 30 English oo kA CJ WN h2 10 1 12 12 18 22 22 25 25 26 26 28 3l 3l 32 33 35 38 38 41 43 45 I Preface This manual is split up into two parts Manual for the user chapters up to and including 4 Manual for the installer This manual contains a glossary chapter 10 The glossary gives a description of the words which are not used in common parlance Also an index is included This enables you to easily find a specific subject in the manual After reading the User Manual you are able to use the IRT 30 clock thermostat You can enter the desired program so that you have the desired temperature at every moment of the day This manual gives an answer to the following question What do you have to know to control the IRT 30 The more technical issues can be found in the manual for the installer In this section you can also find the mounting and installation instructions The installer should also set the IRT 30 In the event of malfunctions you can find information about this in chapter 9 You can also contact your installer 2 Safety regulations Never disassemble the thermostat and do not drop it on the floor the thermostat contains vu
21. ative for the house due to open windows or the use of a fire place is not suitable as a reference room An other reason to appoint a specific room as reference room is that most of the time will be spent in this room Therefore it is important that the temperature regulation of this room is correct The other rooms in the house can have a lower or higher temperature Room temperature controlled regulation This is one of the principles of regulating the temperature in your house According to this regulation the thermostat measures the temperature in the room where it is fitted This measured temperature will be compared with the set desired temperature The thermostat now determines how intensely the boiler must burn to reach or maintain the desired temperature Weather dependent temperature regulation This is a principle of regulation in which the determination of the CH water temperature and the intensity of burning of the boiler is achieved by the outside temperature and a number of preset values in the IRT 30 With this the desired temperature will be reached as close as possible You can influence the temperature in the rooms by using radiators with thermostatic radiator valves Glossary English 43 44 English Weather dependent temperature regulation with room temperature compensation This is one of the ways to regulate the temperature in your house With this principle the CH water temperature and the intensit
22. ble ambient temperature in operation during storage Permissible relative humidity Electrical protection level Dimensions W x H x D Clock program total day programs total switching points per week adjustable by option for clock switching hot water provision Temperature regulation adjustment principle adjustment range smallest adjustable value setting via clock program setting via manual control 18127 18140 2 core polarity free low voltage connection with UBA 4000 1 5 mm 0 C 50 C 20 C 60 C 0 90 non condensing IP 00 175 x 90 x 35 mm 7 70 10 minutes modulates on the basis of room temperature outside temperature combination of both 10 C 30 C 0 5 C digital analogue Contents Contents 10 II Preface Safety regulations Brief description of the IRT 30 3 1 Introduction 3 2 Selecting the correct kind of temperature regulation 3 3 Operating controls 3 4 Information on the display Operation 4 1 General 4 2 Setting the temperature 4 3 Setting the clock 4 4 Clock programs 4 5 Your own clock program 4 6 Special functions Installation of the IRT 30 5 1 Mounting 5 2 Testing the thermostat 5 3 Setting the thermostat Setting the temperature control 6 Selecting a temperature control 6 2 CH menu Setting the hot water supply 7 Checking and or changing the settings 7 2 Hot water menu Configuration and calibr
23. d the TEMPERATURE key Change the time using the program knob Release the TEMPERATURE key You have now changed a switching point After a few seconds the display shows the actual time and the measured room temperature normal mode Inserting an arbitrary switching point If you want to have more switching points in your clock program do the following I Make sure the display is in normal mode refer to figure 3 2 2 Select a switching point using the program knob 4 Press and hold the DAY key and select a day using the program knob N N Ley 17E nuncu oT ee a 5 Release the DAY key 6 Press and hold the TIME key and select a time using the program knob eO 5 obo 5 20000 LLLI 7 Release the TIME key Operation English 15 e 16 English 8 Press and hold the TEMPERATURE key and select a time using the program knob U Bee amp i z 1171 o cti i Vi il LI 9 Release the TEMPERATURE key You have inserted a switching point Inserting a switching point at the current time You can also insert a switching point at the current time I Make sure the display is in normal mode refer to figure 3 2 2 Press and hold the INSERT key and change the temperature using the program knob The temperature indication is blinking 505 S u ad 3 Release the INSERT key when t
24. e any liquid or cleaning agents This may cause short circuiting or damage to the thermostat Outside temperature If you select the weather dependent regulation with or without room temperature compensation you need an outside manually temperature sensor which is connected to the boiler i556 J Without the outside temperature sensor only the room temperature controlled regulation can be used 4 2 Setting the temperature You can set the temperature in two ways I manually figure 4 1 Turn the temperature adjustment knob to the desired temperature refer to figure 4 1 automaticall T The clock program will be switched off 1556 J oF ht 2 automatically Turn the temperature adjustment knob counter clockwise un 4p FIF 2 til the dash points downwards Auto mode refer to figure 4 3 Raise the temperature by pressing the key 0 5 C per step refer to figure 4 3 Lower the temperature by pressing the key figure 4 2 The clock program will not be switched off but adjusted temporarily to your desire At the next switching point the clock program will be activated again The display usually shows the measured temperature in the room and therefore not the set temperature You can see the set temperature by pressing the or key briefly The set temperature will blink for 5 seconds After that the measured room temperature is shown figure 4 3 Operation English
25. e end point of the firing characteristic lower the end point of the firing characteristic Outside temperature is between 0 C and 10 C Warmer raise the starting point as well as the end point of the firing characteristic Colder lower the starting point as well as the end point of the firing characteristic Outside temperature is above 10 C Warmer Colder raise the starting point of the firing characteristic lower the starting point of the firing characteristic 8 Continue setting the hot water supply refer to chapter 7 If floor heating is used we recommend to reduce the maxi mum temperature of the CH water This can be obtained with the UBA of the boiler Reducing the maximum temperature of the CH water prevents too hot water in the floor heating English 27 6 2 CH menu The CH menu appears on the display when you simultaneously press the keys MENU and CH With the CH menu you can select the kind of temperature regulation and set all accompanying features key display I First press w exu 15 80 c 0 2 Press and hold E as the f ELD touts and subsequently press the key e T z RES 8 28 English 75 desired CH water temperature 80 measured CH water temperature 2 5 measured outside temperature these figures are examples For RR only the measured CH water temperature will be shown ECO temperature The lowest tem
26. e in all other rooms which must be heated can be regulated with the thermostatic radiator valves When to apply weather dependent regulation with room temperature compensation When you want to precisely regulate the temperature in more than one room and there is a reference room available When not to apply weather dependent regulation with room temperature compensation When your house does not comply with the above mentioned criteria This is a relatively less economical regulation principle so you should apply this kind of regulation only if strictly necessary English 7 8 English 3 3 Operating controls The IRT 30 can be controlled on two levels refer to the fold out page figure A and B I With the flap closed figure A you now have access to The temperature adjustment knob for manual adjustment of the temperature the and push buttons for temporary adjustment of the temperature within the clock program 2 With the flap open figure B you now have access to 10 operating controls One adjustable program knob by means of which you can scroll through a program and raise or lower the values Nine push buttons for several functions like time setting day setting program setting etc The principle of this operation is push and turn Select the key of the function you want to change and hold it Simultaneously turn the program knob clockwise to raise the value or Simu
27. ent types of installation Installation Type Starting point End point Room influence Radiators 20 C 75 C 6 2 Convectors 40 C 90 C 8 3 Thermostatic radiator valves in the living room 30 C 80 C 0 4 Only floor heating no radiators or convectors 20 C 50 C 4 705 259A 2600 04 2002
28. essary if the boiler also supplies hot water If the hot water supply is set to automatic refer to chapter 4 the thermostat takes care that the water in the boiler will only be heated during the day With the advanced hot water heat up and the hot water stop delay the start and stop points for heating the water can be set The advanced hot water heat up determines how long before the switching point from ECO to another temperature in the clock program the boiler starts heating the boiler water The hot water stop delay determines how long after the switching point to ECO in the clock program the boiler stops heating the boiler water If advanced heat up is set to on refer to chapter 6 the advanced hot water heat up starts heating the hot water calculated from the moment the CH installation starts advanced heating up the house 7 Checking and or changing the settings Check with the hot water menu refer to paragraph 7 2 whether the advanced hot water heat up is set correctly Change the advanced hot water heat up if necessary Check with the hot water menu whether the hot water stop delay is set correctly Change the hot water stop delay if necessary Leave the hot water menu The IRT 30 thermostat is now ready for use Setting the hot water supply English 31 7 2 Hot water menu The hot water menu appears on the display when you simultaneously press the MENU and HOT WATER keys With the h
29. f unheated rooms cold water pipes and draught Do not mount the thermostat in a blind corner of the room Mount the thermostat on a flat surface p F P p 3 Install the wiring 1 Switch off the power supply of the boiler before you install the wiring Install the cable between the boiler and the thermostat Do not connect the cable yet Installation of the IRT 30 To obtain a correct functioning system the wiring should comply with the following specifications the cable must consist of 2 connection wires the thickness of the wire should preferably be 0 75 mm and may not exceed 1 5 mm maximum cable resistance 2 x 5 Ohm maximum cable length 30 m maximum cable length running parallel to a high current cable 2 5 m 4 Mount the mounting plate onto the wall Make sure the power supply of the boiler is switched off I Remove the old thermostat if you want to replace it by the figure 5 1 IRT 30 2 The mounting plate can be fitted to a standard terminal box or directly to the wall 3 Remove the mounting plate from the thermostat At the bottom side of the thermostat are 2 right angled slots Here the click on latches are located Press the click on latches out of the slots using a flat screwdriver refer to figure 5 1 A Remove the mounting plate from the thermostat refer to figure 5 2 figure 5 2 l l l 4 M
30. gram knob to set the amount of days you will be absent Include the current day as a vacation day For weather dependent regulation 4 0 appears in the display instead of ECO l eo 080 EL Ls Release the VACATION key Press and hold the TEMPERATURE key Use the program knob to set the temperature x d o IN Zl 10 41 71054 Release the TEMPERATURE knob Operation Operation On the display a suitcase symbol is shown to indicate the vacation setting is activated Removing the vacation setting You can remove the vacation setting in two ways l Press and hold the VACATION key Use the program knob to set the days to 0 press and hold the REMOVE key All digits change into an 8 and disappear from the right to the left ZOS m Wait until all digits have been removed Release the REMOVE key When you release the REMOVE key before all digits have been removed the vacation setting has not been removed Heating You can switch on or off your CH installation with the HEATING key When you have selected the weather dependent regulation with or without room temperature compensation you also can automatically switch off the heating at a certain outside temperature Set the thermostat as follows e If your thermostat is set to room temperature controlled regulation I Make sure the display is in normal mode refer to figure 3 2 2 Press and
31. he desired temperature is set The switching time is set to the current time rounded off at 10 minutes Removing a switching point I Make sure the display is in normal mode refer to figure 3 2 2 Select the switching point you want to remove with the program knob 4 n c hi CUL 3 Press and hold the REMOVE key All digits change into an 8 and disappear from the right to the left ZOZ fy U 4 Wait until all digits are removed 5 Release the REMOVE key When you release the REMOVE key before all digits have been removed the switching point has not been removed Operation Operation Copy the switching points of the previous day You can copy the switching points set for a day to the next day For example you can copy the switching points from Monday to Tuesday or from Sunday to Monday Note it is only possible to copy the switching points to the next day for example copying switching points from Friday to Monday is not possible I Press and hold the DAY an the INSERT key simultaneously 2 Turn the program knob until the display shows the day number you want to copy to ze STN 3 c Copying is shown by a dash which moves from left to right in the display 2 steps As soon as the settings have been copied the display shows two dashes left of the day number 3 Release the DAY and the INSERT key Return to the
32. ich the temperature is representative for the temperature in the rest of your house This must be a room where for example the fireplace does not burn all day long or the outside door or windows are not open very often Such a room is called a reference room Reference room A reference room is a room for example the living room where a temperature can be measured which is representative for the entire house We assume that the temperature in other rooms for example kitchen or bathroom is equal to the temperature in the reference room An other reason to appoint a specific room as reference room is that most of the time will be spent in this room Therefore it is important that the temperature regulation of this room is correct The other rooms in the house can have a lower or higher temperature Brief description of the IRT 30 Brief description of the IRT 30 What does room temperature controlled regulation mean The IRT 30 continuously measures the temperature in the room where it is fitted The measured temperature will be compared with the desired set temperature The IRT 30 determines how intensely the boiler has to burn to heat the CH water in order to achieve and maintain the desired temperature The IRT 30 calculates the lowest possible water temperature so that the boiler has to burn no more than necessary In general the boiler will therefore burn for a longer period at a lower capacity
33. igure 4 2 ECO means the setting of the night temperature standard set to 16 C English 13 14 English In the standard clock program for the weather dependent regulation you do not find temperatures but scale points One point of the scale corresponds with a temperature range of 0 5 C to 2 C The calculation starts at 0 which corresponds with a standard room temperature 20 C Consequently means 18 19 5 C and means 20 5 22 C point does not correspond with C Where setting or changing of the temperature is mentioned A in the text you must change the scale points for the weather dependent regulation This is possible with steps of 0 5 points 4 5 Your own clock program Instead of using the standard clock program it is also possible to create your own clock program In doing so you can create a clock program appropriate for your daily schedule For each switching point you can adapt the time and the temperature Furthermore you can insert or remove switching points Changing a switching point I Make sure the display is in normal mode refer to figure 3 2 2 Select the switching point you want to change using the program knob fa Uh Pu aT zu 3 Change the time as follows Press and hold the TIME key Change the time using the program knob Release the TIME key Operation 4 Change the temperature as follows Press and hol
34. l appears Configuration and calibration of the IRT 30 thermostat 3 In the middle of the display the temperature to which the temperature adjustment knob is set is shown On the right side a blinking temperature which you can alter is shown GO cui a m PNI 4 Turn the program knob while holding the MENU and OM REMOVE keys until the blinking temperature reflects the temperature onto which the temperature adjustment knob is set 5 Release all keys when you are finished Calibration of the outside temperature sensor The outside temperature sensor should be calibrated when the measured temperature shown on the display deviates from the actual outside temperature at the outside temperature sensor Note The outside temperature sensor can only be calibrated when it is connected to the boiler and the weather dependent regulation WD or WD RTC has been set You can calibrate the outside temperature sensor as follows I Make sure the display is in normal mode refer to figure 3 2 i Ex 2 Simultaneously press the MENU and REMOVE keys three times and hold them To the right on the display the TEMP BUITEN symbol appears In the middle of the display the temperature to which the temperature adjustment knob is set is shown On the right side a blinking temperature which you can alter is shown ic i co EM 3 Turn the program knob while holding the MENU and OH REMOVE key
35. lnerable electronic parts and sensitive sensors Avoid high temperatures moist and dusty surroundings Do not use liquids or cleaning agents to clean the thermostat Switch off the power supply of the CH before you install the thermostat Make sure the power supply of the CH is actually switched off 2 English Preface and Safety regulations Brief description of the IRT 30 3 Brief description of the IRT 30 3 Introduction The IRT 30 clock thermostat has been specially developed for the use with boilers fitted with the universal burner auto unit UBA 4000 The IRT 30 is designed for wall mounting and is powered via a connection to the boiler Thus the thermostat does not use any batteries By making use of a computer program the thermostat continuously receives data from the boiler and the other way around With this information the thermostat is able to give instructions to comfortably heat your home supply the boiler with hot water at the right time save as much energy as possible You can program the IRT 30 with a maximum of 70 switching points for one week Furthermore you can change the switching points and remove or insert them Switching point A switching point is a setting in your clock thermostat It is a moment in time at which you desire a different temperature To set this you have to enter the desired time and the desired temperature In paragraph 4 4 this will be explained in det
36. ltaneously turn the program knob counter clockwise to lower the value In chapter 4 operation will be explained in detail 3 4 Information on the display The screen also referred to as display shows information about the operation of the boiler and the thermostat by means of digits and symbols The display in figure 3 1 shows all possible symbols Beside this the meaning of each symbol is described 2D A8 p eii C Becas Has figure 3 1 Brief description of the IRT 30 Brief description of the IRT 30 boiler does not heat the CH water hot water supply OFF clock program is shown boiler heats the CH water hot water supply ON Boiler heats CH water according to clock program hot water supply AUTO CH boiler ON room temperature controlled regulation is active weather dependent regulation is active weather dependent regulation with room temperature compensation is active CH boiler OFF automatic summer winter mode only when outside temperature sensor is connected each block 0 5 C lower higher night setting ECO mode vacation setting boiler display code may indicate malfunction day number Monday Tuesday 2 Sunday 7 time indication temperature indication English 9 10 English During programming the display shows information about the switching points of the program In rest normal mode the following is shown on the display
37. m 4 L 3 Turn the program knob while holding the INSERT key until the desired PID number appears in the display 4 Release the INSERT key 4 Reset the thermostat You can switch off the thermostat and switch it on again reset This causes the thermostat to run the start and test program again refer to paragraph 5 2 You can reset the thermostat as follows I Simultaneously press the MENU INSERT and REMOVE key and release them 2 Again press the INSERT key three times and hold it On the display tESt appears PA als DR s Z M TT Pe wm 3 Release the INSERT key 8 2 Calibration Although the sensors of the IRT 30 thermostat are of high quality some irregularities can not be avoided in the long term You can recalibrate the sensors then Only recalibrate the sensors when the measurement deviation becomes clearly evident and irritating Incorrect calibration may have serious consequences to the operation of the thermostat Preferably let the installer recalibrate the thermostat during a service visit Configuration and calibration of the IRT 30 thermostat English 35 36 English Calibration of the temperature sensor of the thermostat The temperature sensor in the IRT 30 thermostat should be calibrated when the measured temperature shown on the display deviates from the actual temperature It is no simple task to determine the actual temperature in the r
38. n normal mode refer to figure 3 2 2 Press and hold the HOT WATER key The display shows the current hot water mode SHO 3 Turn the program knob to change the mode of the hot water supply Successively the modes ON OFF and AUTO will be shown Set the desired mode using the program knob e ON oa AUTO 4 Release the HOT WATER key In the AUTO mode the hot water supply will be switched off when the ECO mode in the clock program is set Operation English 21 7 150 cm 22 English 5 Installation of the IRT 30 This chapter is important for installers and may also be of interest to some users 5 1 Mounting I Check the contents of the package The package should contain the following clock thermostat IRT 30 with mounting plate bag with 2 screws 2 washers and 2 plugs this manual 2 Find a suitable mounting position The thermostat should be mounted to an inside wall at a distance of approximately 150 cm above the floor Consider the following when searching for a suitable mounting position There should be enough air circulation around the thermostat but no draught The air temperature should be representative for the whole room Do not mount the thermostat too near heat sources like radiators hot water pipes tv sets radios fire places lamps or incoming sunlight Do not mount the thermostat too near cold sources like walls o
39. nd the display codes of the boiler Clock loses gains time Time indication is blinking I The time indication blinks after a power failure or as a result of an interruption of the connection to the boiler Check the time setting and press the TIME key to let the clock run normally again 2 Contact your installer when the clock loses or gains time Malfunction of the communication I Is the wiring of the IRT 30 thermostat connected to terminal 3 and 4 of the terminal block in the boiler 2 only for WD and WD RTC Has the correct wiring preferably 0 75 mm2 for connection of the outside temperature sensor been used Does the wiring run along a 230 V power supply cable 3 Is the cable defective You can check this by connecting the IRT 30 thermostat directly to terminal 3 and 4 of the boiler using a short cable 9 2 Boiler display codes When you press the HEATING key a boiler display code appears in the display for 3 seconds This code is shown on the position of the temperature indication A boiler display code consists of two symbols The first symbol indicates the current function of the boiler the second symbol indicates which part of the function is active or in some cases is not active In case of a malfunction the display shows the symbol of a mechanic refer to figure 9 1 Press the reset button on the boiler when an error code appears on the display of the thermostat If the malfunction keeps repe
40. ntrol Installation type The type of installation Radiators 2 Convectors 3 Thermostatic radiator valves in the living room 4 Only floor heating no radiators or convectors To each type of installation a special firing characteristic is attached starting point end point room influence refer to table 6 1 Starting point The desired CH water temperature at 20 C This is called the starting point of the firing characteristic End point The desired CH water temperature at 10 C This is called the end point of the firing characteristic Room influence A factor which indicates the influence of the room temperature to the WD RTC control English 29 Minimum CH water temperature 0 l The thermostat takes care that the CH water temperature can never drop below this value Standard the minimum CH water temperature is set to 10 C If you release the CH key and wait for 5 seconds the display returns to normal mode Table 6 1 Standard firing characteristics for different types of installation Installation type Starting point End point Room influence Radiators 20 C 75 C 6 2 Convectors 40 C 90 C 8 3 Thermostatic radiator valves in living room 30 C 80 C 0 4 Only floor heating no radiators or convectors 20 C 50 C 4 30 English Setting the temperature control 7 Setting the hot water supply This chapter is only nec
41. oom The position you are measuring and the accuracy of the thermometer you are using may influence the result t is also important to measure the temperature when the tempe rature is stable i e not during the heat up periods etc You can recalibrate the temperature sensor as follows I Make sure the display is in normal mode refer to figure 3 2 2 Press and hold the MENU and then REMOVE key Hold both keys In the middle of the display the temperature which is measured by the sensor in the thermostat is shown On the right side a blinking temperature which you can alter is shown 41 cL 26 3 Turn the program knob while holding the MENU and REMOVE keys until the blinking temperature indicates the actual temperature Tu at Ch gt lew o 4 Release all keys when you are finished Calibration of the temperature adjustment knob Calibration of the temperature adjustment knob of the thermostat may be necessary when the actual temperature deviates from the temperature which is set manually with the temperature adjustment knob For example the temperature adjustment knob is set to 20 C but in the long term the actual temperature never rises above 19 C You can calibrate the temperature adjustment knob as follows I Make sure the display is in normal mode refer to figure 3 2 2 Simultaneously press the MENU and REMOVE keys twice and hold them To the right on the display the TEMP symbo
42. ot water menu you can set during which period of the day hot water is available key display I first press D 75 desired CH water temperature 75 00 25 Qs 80 measured CH water temperature 2 5 measured outside temperature these figures are examples For RR only the measured CH water temperature will be shown Advanced hot water heat up e key and aa The time during which the water in the boiler is press on already heated up before the CH installation starts heating up the house This time can be set from 0 to 120 minutes Standard the value is set to 30 minutes release the Hot water stop delay B key 38 The time during which the water in the boiler is still heated after the CH has been switched over to the ECO temperature This time can be set from 0 to 120 minutes Standard the value is set to 30 minutes When you release the HOT WATER key and wait for 5 seconds the display returns to the normal mode 32 English Setting the hot water supply 8 Configuration and calibration of the IRT 30 thermostat This chapter is intended for the installer Configuration and calibration of the IRT 30 thermostat are only necessary in exceptional situations 8 1 Adapting the configuration The IRT 30 thermostat can be adapted with a few settings to the speed and the capacity of the CH installation These settings are included in the configuration menu
43. perature which can be used in a clock program Standard the ECO temperature is set to 16 C Advanced heat up yes I no 0 only for RR and WD RTC If the advanced heat up is set to off the boiler starts heating at the moment when the clock program switches over from a low temperature setting to a higher temperature setting If the advanced heat up is set to on the thermostat takes care that the boiler starts heating earlier so that the desired temperature is reached at the switching point of the thermostat The thermostat learns in the long term how much earlier the boiler must start heating Standard the advanced heat up is set to on yes 1 Kind of temperature regulation The kind of temperature regulation which is selected The set regulation can be recognised by the symbol on the display Setting the temperature control a room temperature controlled regulation RR y weather dependent regulation without room temperature compensation WD as weather dependent regulation with room temperature compensation WD RTC for WD and WD RTC the outside temperature will be displayed in the right bottom corner of the display as well The settings described below are only applicable for weather dependent regulation with or without room temperature compensation 1 i k T eg st aU ae t i wes 6 Setting the temperature co
44. rature settings on these points in time Operation Operation Switching point A switching point is a setting in your clock thermostat It is a point in time at which you desire another temperature To set the switching point you have to enter the desired time and the desired temperature You can check the switching points by slowly turning the program knob You will see the day number time and temperature for each switching point Looking to the clock program you can see a clock in the left upper corner of the display As soon as you change a setting in the clock program the clock symbol starts blinking The IRT 30 is supplied with a standard clock program This program looks like this For room temperature controlled For weather dependent regulation regulation and weather dependent regulation with room temperature compensation Monday to Friday Monday to Friday day number t m 5 day numbers t m 5 700u 21l C 700u 10 9 00u 19 C 9 00u 1 0 17 00u 21 C 17 00u 10 23 00u ECO 2300u 4 0 Saturday and Sunday Saturday and Sunday day number 6 en 7 dagnummers 6 en 7 8 00u 21 C 800u 1 0 23 00 u ECO 23 00u 4 0 30 c 25 C T 11 00 1300 15 00 7 00 9 00 11 00 13 00 15 00 17 00 900 21 00 2300 e switching point e Switching point Mo to Fri Mo to Fri Sat Sun 2 Sa Sun This program is activated when the temperature adjust knob is in AUTO refer to f
45. s until the blinking temperature reflects the actual outside temperature 4 Release all keys when you are finished Configuration and calibration of the IRT 30 thermostat English 37 38 English 9 Malfunctions and the display codes of the boiler In this chapter some possible problems malfunctions will be described Furthermore the possible solutions will be given You can always contact your installer if the problems persist For some items the solution depends on the set kind of regulation This will be reflected by the following abbreviations RR room temperature controlled regulation WD weather dependent regulation WD RTC weather dependent regulation with room temperature compensation 9 Malfunctions During heat up an annoying ticking sound is heard in the pipes At the beginning of the day the water will be heated up as quickly as possible to enable the radiators to warm up the rooms as quickly as possible The metal tubes will expand because of the sudden temperature rise which may result in a ticking sound I Increase the PID setting to reduce the heat up speed of the installation 2 Set slow temperature rise to ON 3 If the capacity of the boiler is much higher then necessary the water will be heated up too fast By means of the partial load potentiometer on the UBA the maximum capacity for heating up the water can be reduced so that the water will be heated up more slowly
46. standard clock program It is always possible to return to the standard clock program This will erase all other switching points I Make sure the display is in normal mode refer to figure 3 2 2 Press and hold the TIME REMOVE and INSERT key All digits change into an 8 and disappear from the right to the left 3 Wait until all digits have been removed 4 Release the TIME REMOVE and INSERT key When you release the keys before all digits have been removed the standard clock program has not been activated your own switching points will be maintained English 17 18 English I 2 3 on 4 6 Special functions Look at the current display codes of the boiler Briefly press the HEATING key The display codes of the boiler will be shown for 3 seconds on the temperature position Also refer to paragraph 9 2 and the installation instructions of your boiler Ww e x Look at the outside temperature When the thermostat is set to weather dependent regulation you are able to look at the outside temperature Briefly press the MENU key The outside temperature will be shown for 3 seconds Vacation setting With this function you can set a lower temperature for a longer period without changing the clock program This is called the vacation setting Make sure the display is in normal mode refer to figure 3 2 Press and hold the VACATION key Use the pro
47. y of burning of the boiler is determined in the first instance by the outside temperature and the preset values on the IRT 30 However the thermostat also measures the temperature in the room where it is fitted The temperature in the room where the thermostat is fitted is determined by the thermostat itself This measured temperature is compared with the set desired temperature The thermostat can now correct the preset values to ensure the desired temperature can actually be reached or maintained Firing characteristic The firing characteristic is a line which shows the temperature of the CH water at a certain outside temperature You can set the firing characteristic with the help of 2 points the desired water temperature at 20 C outside temperature starting point the desired water temperature at 10 C outside temperature end point Glossary Il Index Advanced heat up 27 Air heating 5 Boiler display codes 18 37 40 Change switching point 14 Connection wiring 23 Control principle 10 Convectors 5 CV menu 27 Display 8 ECO temperature 27 Firing characteristic 25 29 43 Heat up speed 32 Hot water menu 31 Hot water supply 20 30 Insert switching points 15 16 Installation 21 Maintenance l Malfunctions 37 Mounting 21 Outside temperature l 26 Outside temperature sensor 4 36 Power I Reference room 4 Reset 33 Room temperature controlled regulation 4 42 Safety regulations 2