ONYX-1222 1st edition manual 2014

image

Contents

1. Reader optional Chapter 1 General Information 1 2 Slim Medical Panel PC ONYX 1222 1 3 Specification Hardware Specifications Display 11 6 1366x768 LCD CPU Intel Celeron J1900 Processor Disk Drive 5 Hard Disk Drive Solid State Drive Space Expansion N A Function Power On Off Speaker Volume Up Down LCD Brightness Key Up Down VO 1x Isolated RS 232 port 4x USB 2 0 ports 2x Isolated Gigabit LAN Sound 1 x Line out 1 x Mic in LCD Specifications Display Type 11 6 LCD Max Resolution 1366 x 768 Max Colors 16 7M Dot Size mm 0 1875 x 0 1875 Luminance cd m2 400 TYP Back Light Life Time gt 15 000 Hrs Chapter 1 General Information 1 3 Slim Medical Panel PC ONYX 1222 Note All ONYX LCD products are manufactured with High precision technology However there are a small number of defective pixels in all LCD panels that are not able to change color This is a normal occurrence for all LCD displays from all manufacturers and should not be noticeable or objectionable under normal operation All LCD panels are qualified for industry standard conditions in the following total 7 dead pixels on a screen or if there are 3 within 1 inch square area of each other on the display Chapter 1 General Information 1 4 Slim Medical Panel PC ONYX 1222 Mechanical Specifications Architecture Close frame Front Bez
2. Onyx Healthcare SU ZHOU INC Room 12 2F Building B No 5 Xing Han Street Suzhou Industrial Park Jiang Su Province China Tel 86 512 67625700 Fax 86 512 6761 7337 Email cnsales onyx healthcare com Onyx Healthcare Singapore PTE LTD 57 Genting Lane 07 00 Singapore 349564 Tel 65 67498749 Fax 65 67461595 Email sgsales onyx healthcare com Slim Medical Panel PC ONYX 1222 Safety amp Warranty 1 Read these safety instructions carefully Keep this user s manual for later reference Disconnect this equipment from any AC outlet before cleaning Do not use liquid or spray detergents for cleaning Use a damp cloth 4 For pluggable equipment the power outlet must be installed near the equipment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall could cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before connecting the equipment to the power outlet 9 Warning To avoid risk of electric shock this equipment must only be connected to a supply mains with protective earth Avertissement Pour viter tout risque de choc lectrique cet appareil doit tre connect une alimentation secteur avec une prise de terre 10 Position the power cord so that
3. Medical Panel PC ONYX 1222 Chapter Hardware Installation Chapter 2 Hardware Installation 2 1 Slim Medical Panel PC ONYX 1222 2 1 Safety Precautions Warning Always completely disconnect the power cord from your board whenever you are working on it Do not make connections while the power is on because a sudden rush of power can damage sensitive electronic components Always ground yourself to remove any static charge before touching the board Modern electronic devices are very sensitive to static l a electric charges Use a grounding wrist strap at all times Place all electronic components on a static dissipative surface or in a static shielded bag when they are not in the chassis Caution Chapter3 Award BIOS Setup 3 1 Slim Medical Panel PC ONYX 1222 2 2 Quick Tour of ONYX 1222 Before you start to set up ONYX 1222 take a moment to become familiar with the locations and purposes of the controls drives connections and ports which are illustrated in the figures below When you place ONYX 1222 upright on the desktop its front panel appears as shown in Picture 2 1 Barcode Scanner optional m Handset optional M SR optional Picture 2 1 Front View of ONYX 1222 Series Chapter3 Award BIOS Setup 3 2 Slim Medical Panel PC ONYX 1222 When you turn the Medical Station around and look at its rear cover the sunken I O section is at the bottom of the station as
4. people cannot step on it Do not place anything over the power cord 11 All cautions and warnings on the equipment should be noted Slim Medical Panel PC ONYX 1222 12 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient over voltage 13 Never pour any liquid into an opening This could cause fire or electrical shock 14 Never open the equipment For safety reasons only qualified service personnel should open the equipment 15 Warning Do not modify this equipment without authorization of the manufacturer Avertissement Ne pas modifier cet quipement sans l autorisation du fabricant 16 Warning It is necessary for checking or replacing the battery pack every year Avertissement Il est n cessaire de v rifier ou de remplacer la batterie chaque ann e Slim Medical Panel PC ONYX 1222 16 If any of the following situations arises get the equipment checked by service personnel a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the users manual e The equipment has been dropped and damaged f equipment has obvious signs of breakage 17 DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 140 F IT MAY D
5. shown in Picture 2 2 The I O section includes various I O ports including a serial port two Ethernet ports four USB ports the microphone jack and so on Line out Isolated Gigabit LAN x 2 Isolated COM Portx 1 T USB 2 0x 4 Picture 2 2 Rear view of ONYX 1222 Series Chapter3 Award BIOS Setup 3 3 Slim Medical Panel PC ONYX 1222 When you turn ONYX 1222 around and look at its right side one USB 3 0 port and the smart card reader are on the right side as shown in Picture 2 3 Smart Card Reader optional USB3 0x1 Picture 2 3 Right view of ONYX 1222 Series Chapter3 Award BIOS Setup 3 4 Slim Medical Panel PC ONYX 1222 2 3 Turn On and Boot up into Windows OS This section is for Windows operating system only If you are installing a different operating system please contact your vendor for installation details Your ONYX 1222 will begin loading Windows OS once you push the power button to turn power on After less than one minute Windows desktop screen will appear You can select the programs from the start menu in the left down corner of the desktop screen 2 4 Turn off Turning off ONYX 1222 properly is important for system reliability There are two ways to turn off the system 1 On start menu click shut down and select OK 2 Push the power button and then the system will shut down automatically Chapter3 Award BIOS Setup 3 5 Slim Medical Panel PC ON
6. the maintenance or are beyond repair we strongly recommended that you should inform us as soon as possible for the suitable solution For the computers that are no longer useful or work well please contact with worldwide distributors for recycling The worldwide distributors show on the following website http www onyx healthcare com tw Contact php Note Follow the national requirement to dispose unit Appendix Miscellanea A 5 Smart Healthcare
7. AMAGE THE EQUIPMENT 18 External equipment intended for connection to signal input output or other connectors shall comply with relevant UL IEC standard e g UL 1950 for IT equipment and ANSI AAMI ES 60601 1 2005 AND CAN CSA C22 2 No 60601 1 08 IEC 60601 series for systems shall comply with the standard IEC 60601 1 1 Safety requirements for medical electrical systems Equipment not complying with UL 60601 1 shall be kept outside the patient environment as defined in the standard Caution It may cause the danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer Slim Medical Panel PC ONYX 1222 Classification 1 Degree of production against electric shock not classified 2 Degree of protection against the ingress of water IPXO 3 Mode of operation Continuous 4 Type of protection against electric shock Class equipment 5 No Applied Part No AP APG Slim Medical Panel PC ONYX 1222 FCC Warning This device complies with Part 18 FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Slim Medical Panel PC ONYX 1222 UL Module Description oie C US ONYX 1222 module is developed to suitable for the Classification Mark require
8. Slim Medical Panel PC ONYX 1222 ONYX 1222 11 6 LCD with LED Backlight Intel Celeron J1900 Quad Core Processor Slim Medical Panel PC ONYX 1222 Manual 1st Ed Dec 2014 Slim Medical Panel PC ONYX 1222 Copyright Notice This document is copyrighted 2014 All rights are reserved The original manufacturer reserves the right to make improvements to the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to assure its accuracy ONYX Healthcare Inc assumes no liabilities resulting from errors or omissions in this document or from the use of the information contained herein ONYX Healthcare Inc reserves the right to make changes in the product design without notice to its users Slim Medical Panel PC ONYX 1222 Acknowledgments e Intel Celeron is registered trademarks of Intel Corporation e IBM PC AT PS 2 are trademar
9. YX 1222 Chapter Driver Installation Chapter3 Driver Installation 3 1 Slim Medical Panel PC ONYX 1222 There are several installation ways depending on the driver package under different Operating Systems Please follow the sequence below to install the drivers For Windows 7 Step 1 Chipset Driver Step 2 Graphics Driver Step 3 LAN Driver Step 4 Audio Driver Step 5 USB 3 0 Driver Step 6 Resistive Touch Driver only for ET series Step 7 TPM Driver Step 8 Barcode Scanner Driver optional Step 9 USB Audio for Handset optional For Windows 8 Step 1 Chipset Driver Step 2 Graphics Driver Step 3 MBI Driver Step 4 TXE Driver Step 5 LAN Driver Step 6 Audio Driver Step 7 Resistive Touch Driver only for ET series Step 8 TPM Driver Chapter 4 Drivers Installation 3 2 Slim Medical Panel PC ONYX 1222 Step 9 Barcode Scanner Driver optional Step 10 USB Audio for Handset optional Chapter 4 Drivers Installation 3 3 Smart Healthcare Slim Medical Panel PC ONYX 1222 Appendix Miscellanea Appendix A Miscellanea 1 Slim Medical Panel PC ONYX 1222 A 1 General Cleaning Tips You may need the following precautions before you begin to clean the computer When you clean any single part or component for the computer please read and understand the details below fully 1 Never spray or squirt the liquids directly o
10. el Plastic bezel with resistive touch screen Color White Mounting Holder VESA 75 100mm Screw type M4 8mm Construction 3mm ABS PC TYPE Plastic housing Dimension WxHxD 300mmx 208mm x 39 mm Net Weight 3 3 Ib 1 5 Kg Power Supply Specifications Model Eljintek Inc GMPU70A 6 Input Voltage 100 240V AC 50 60 Hz Output Voltage 24V 2 91 70W max Model Adapter ATM065 P120 Input Voltage 100 240V AC 9 50 60 Hz Output Voltage 12V 5A 60W max Chapter 1 General Information 1 5 Slim Medical Panel PC ONYX 1222 Environmental Specifications Operating Temperature 0 C to 40 C 32 F 104 Operating Humidity 30 to 75 RH non condensing Operating Pressure 700 to 1033 hPa Storage Temperature 20 C to 60 C 4 F 140 F Storage Humidity 10 to 90 RH non condensing Storage Pressure 700 to 1033 hPa Vibration 0 5G 5 500Hz Random operation Shock 20G peak acceleration 11 msec duration operation Drop 76cm 1 Corner 3 Edge 6 Surface EMI Safety CE FCC Class B ANSI AAMI ES60601 1 EN 60601 1 Touch Screen Type Projective Capacitive 5 wire Resistive Interface USB interface Light Transmission gt 75 Chapter 1 General Information 1 6 Slim Medical Panel PC ONYX 1222 1 4 Dimension 208 Chapter 1 General Information 1 7 Slim
11. ks of International Business Machines Corporation e Microsoft Windows is a registered trademark of Microsoft Corporation e HILisa trademark of Realtek Semi Conductor Co Ltd All other product names or trademarks are properties of their r espective owners Slim Medical Panel PC ONYX 1222 Packing List Before you begin installing your Medical Station please make sure that the following items have been shipped m ONYX 1222 Slim Medical Panel n Utility DVD ROM which contains Drivers and Utilities Slim Medical Panel PC ONYX 1222 If any of these items are missing or damaged you should contact your distributor or sales representative immediately Headquarters Onyx Healthcare Inc 2F No 135 Lane 235 Pao Chiao Rd Hsin Tien City Taipei 231 Taiwan R O C TEL 886 2 8919 2188 FAX 886 2 8919 1699 E mail sales onyx healthcare com http www onyx healthcare com Worldwide Offices Onyx Healthcare USA Inc 2663 Saturn street Brea CA 92821 USA Tel 1 714 996 1800 Fax 1 714 996 1811 Email usasales onyx healthcare com Onyx Healthcare EUROPE B V Ekkersrijt 4002 5692 DA Son The Netherlands Tel 31 0 499 462020 Fax 31 0 499 462010 Email eusales onyx healthcare com Slim Medical Panel PC ONYX 1222 Onyx Healthcare Technology GmbH An der Trift65d 63303 Dreieich Germany TEL 49 0 61033 7479 00 Fax 49 0 61033 7479 49 Email eusales onyx healthcare com
12. ment Slim Medical Panel PC ONYX 1222 Safety Symbol Description The following safety symbols are the further explanations for your reference Medical equipment with respect to electric shock fire and mechanical hazards only in accordance with ANSI AAMI ES 60601 1 2005 AND CAN CSA C22 2 No 60601 1 08 Attention consult ACCOMPANYING DOCUMENTS VA e S ev o Stand by Ground wire Protective Ground wire qm Slim Medical Panel PC ONYX 1222 Contents Chapter 1 General Information 1 1 INtrOAUCtion iii 1 2 1 2 FeatUte eec eee cer ti 1 3 1 3 1 4 1 4 DIMENSION 1 8 Chapter 2 Hardware Installation 2 1 Safety Precautions eese 2 2 2 2 Quick Tour of ONYX 1222 ness 2 3 2 3 Turn and Boot up into Windows 2 7 ov reine 2 7 Chapter 3 Driver Installation Appendix A Miscellanea A 1 General Cleaning 1 1 1 1 1 1 3 8 C 2 A 2 Cleaning Tools crei C 3 Scrap Computer Recycling C 5 Slim Medical Panel PC ONYX 1222 Chapter General Information Slim Medical Panel PC ONYX 1222 1 1 Introduction ONYX 1222 Slim Medical Panel PC is based
13. nto any computer component If you need to clean the device please rub it with a piece of dry cloth 2 Be cautious of the tiny removable components when you use a vacuum cleaner to absorb the dirt on the floor 3 Turn the system off before you start to clean up the component or computer 4 Never drop the components inside the computer or get circuit board damp or wet 5 Be cautious of all kinds of cleaning solvents or chemicals when you use it for the sake of cleaning Some individuals may be allergic to the ingredients 6 Try not to put any food drink or cigarette around the computer 7 ONYX Healthcare Inc has tested and verified these cleaning disinfectants CIDEX Viraguard Control IIl Disinfectant Germicide Caviwipes Dispatch Disinfectant Cleaner CLH69101 Puregreen 24 Disinfectant can be used with ONYX 1222 Use of any other disinfectants will Appendix A Miscellanea A 2 Slim Medical Panel PC ONYX 1222 void the warranty A 2 Cleaning tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items to clean their computers and peripherals Below is a listing of items you may need or want to use while cleaning your computer or computer peripherals Keep in mind that some components in your computer may only be able to be cleaned using a product designed for cleaning that component if this is the case it will be men
14. on Intel Celeron 41900 Quad Core processor which delivers performance improvement of more than 100 percent compared to systems running traditional single core processors With four cores computing engines ONYX 1222 can simultaneously execute four computing tasks It accommodates one 2 5 SATA hard disk drive SSD and two DDRIII SODIMM up to 8GB The high brightness LCD zero noise solution integrated multimedia functions make them the perfect platform upon which to build comprehensive lifestyle computing applications ONYX 1222 includes all the features of a powerful computer into a slim and attractive chassis It has a 11 6 400 nits TFT display with 1366 x 768 resolution ONYX 1222 owns a side mounted USB 3 0 port and a smart card reader to support high speed data transfer and ID check Combining ONYX 1222 into your system can achieve both cost saving and efficient improvements in common applications including Surgical Radiology PACS Picture Archiving Communication Systems LIS Lab Information Systems and Electronic Medical Record ONYX 1222 is definitely your perfect choice Chapter 1 General Information 1 1 Slim Medical Panel PC ONYX 1222 1 2 Feature e Intel Celeron J1900 Quad Core Processor Supports Dual Channel DDR3 SODIMM up 8GB Built in RFID and Smart Card Security Optional e High Speed USB 3 0 Port 5 Smart Function Keys e Handset with remote control Optional Magnetic
15. tioned in the cleaning tips e Cloth A piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be used on most hardware as well we still recommend you to rub it with a piece of cloth e Water or rubbing alcohol You may moisten a piece of cloth a bit with some water or rubbing alcohol and rub it on the computer Unknown solvents may be harmful to the plastics parts e Vacuum cleaner Absorb the dust dirt hair cigarette particles and other particles out of a computer can be one of the best methods of cleaning a computer Over time these items can restrict the airflow in a computer and cause Appendix Miscellanea A 3 Slim Medical Panel PC ONYX 1222 circuitry to corrode e Cotton swabs Cotton swaps moistened with rubbing alcohol or water are excellent tools for wiping hard to reach areas in your keyboard mouse and other locations e Foam swabs Whenever possible it is better to use lint free swabs such as foam swabs Note We strongly recommended that you should shut down the system before you start to clean any single components Please follow the steps below Close all application programs Close operating software Turn off power switch Remove all device OT e oc Pull out power cable Appendix Miscellanea A 4 Smart Healthcare Slim Medical Panel PC ONYX 1222 A 3 Scrap Computer Recycling If the computer equipments need