iLink LCD by Nel-Tech Labs, Inc. Installation & User Manual

image

Contents

1. MADE IN USA CHANNEL A i 6002 CHANNEL B i 6000 Ou 6n o o O 2 2 3 fe a T o o o o n m gt 5 z 5 S O 5 Os iS ss Ze SE E M m o bes o ow g g A 2 F 10 Connectivity Test Step 1 Verify the power switch on the right side of the unit is set to ON Step 2 On the LCD menu verify unit has a valid IP subnet gateway connect back amp port Example Step 3 On the LCD menu go to the PRESS UP ARROW TO CONNECT BACK and press the UP ARROW Example Step 4 The LCD will display the FORCING CONNECT PLEASE WAIT Example Step 5 If there is a Connect Back record waiting for the unit then the LCD will display ACTIVE CONNECT XXX XXX XXK XXX Example If there is no record waiting then it will display CONNECT TO XXX XXX XXX XXX for one second on the LCD to confirm a successful connectivity Example 11 Channel A amp B Output Level Adjustments Step 1 Verify CHANNEL A or B OUT is connected to either a phone s MOH port PA amplifier or speaker MADE IN USA CHANNEL A Boon CHANNEL B E soon a n IN OUT msn IN OUT m8 and or Step 2 Verify the unit is playing audio by listening to the internal monitor speaker VA Cycles Inte
2. iLink LCD by Nel Tech Labs Inc Installation amp User Manual Includes special section for iLink LCD LR Local Record Option Index Titrod cti oeei iniedi n voodoo nedo udo dosud E EE je 3 ilink Layout Summarys ceire errea aD Sedna e E EEE solo da 4 5 ECD L yout SUMMARY sesiis iee aai E EEEE i aa E E 6 8 Web BrOWSET arii e da dua Slo davno SB VSA koed EAA 9 Stala toe ako ari en A TA d ato Ku Sahat nooo Men Ueda 10 12 Connectivity Test Volume AdjustmieRtS s ads shoda de bands de aeawds 13 Troubleshoot 33536 ebusooi aE th Ada onde A bettie Mrs dy VA a ooo toky 14 Warranty FOC oe ussod o sud n skon E E E 15 Introduction The iLink LCD is an Internet downloadable messaging system utilizing state of the art MPEG compression to achieve truly stunning near CD quality audio storage and playback All unit management and audio downloads are accomplished by your dealer using a special controller software suite When an update is needed your dealer connects to the iLink via your high speed Internet connection and digitally transfers the MP3 audio files and configuration settings you need Changes can be initiated on demand scheduled from minutes to weeks or the iLink can be instructed to connect automatically and load new audio With the Local Record option users can record up to 16 message slots set interval time and select internal or external background music sources all from LCD interface Unpacking and Inspectio
3. Down to Cancel VA Changes Port gt Up to Confirm Down to Cancel Up to Confirm Up to Confirm Down to Cancel Pressing MENU advances through menu selections Pressing SELECT chooses menu option to be changed Note Changes to IP Settings only available in STATIC MODE If MAIN MENU item is idle for more than 90 seconds the LCD reverts back to MAIN SCREEN If SUB MENU is idle for more than 90 seconds the LCD reverts back to MAIN SCREEN and CANCELS any current changes LOCAL RECORD OPTION LCD Menu Feature on Channel A Only Before recording make sure microphone is plugged into unit Example Local Record 1 Press MENU until the LOCAL SLOTS screen is on the LCD 2 Press SELECT 3 On the SELECT SLOT menu the selected slot will have a Press the VA arrows until the slot that is to be changed has a 4 Press SELECT 5 ON the SELECT MODE menu press the W A arrows to choose the record play activate deactivate or delete function to be used in that slot 6 Press SELECT and the following action on that slot will occur a RECORD gt PLAY gt ACTIVATE gt DEACTIVATE gt DELETE gt e200 Recording Tips Recording should be performed about 6 to 8 inches from the microphone Maxiumum time of 45 seconds per slot is available for recording After RECORD function slot will be placed in DEACTIVATED Mode Interval 1 Press M
4. Volume If you see a LOCKED VOLUME SETTINGS message then the dealer has locked this setting Step 4 All volume adjustments are applied live so changes are saved to the unit instantly 13 Other LCD Status Messages Unit is booting Unit is initializing Unit is getting ip address Dealer is connected to unit Unit is connected to dealer Format in progress Unit is formatting Local Record Mode Only LAN LED Indicators LAN Yellow LL Green TOMB way OFF FLASHING FLASHING 100MB SOLID aa SOLID 14 Limited Warranty TERMS Nel Tech Labs warrants to the original purchaser Buyer that the Product sold is free from defects in material and workmanship at the time of purchase The warranty period begins at the time of Product s original purchase by the first end user The warranty applies for five 5 year from the original date of purchase or as long as the product is owned by the original purchaser whichever comes first Included in the warranty are parts and labor Buyer must provide written notice to Nel Tech Labs of any defective part or conditions within the warranty period If the defect is not the result of improper use service maintenance or installation and if the equipment has not been otherwise damaged or modified after shipment Nel Tech Labs or its authorized representative shall either replace or repair the defective Product at Nel Tech Labs s option No credit shall
5. ENU until the LOCAL INTERVAL is on the LCD 2 Press SELECT 3 Press the W A arrows to select interval time from 1 to 3600 seconds Hold V A arrows to increment or decrement interval time faster 4 Press SELECT to accept change Default Setting DEACTIVATED Background Music Source BGM 1 Press MENU until the LOCAL BGM SOURCE is on the LCD 2 Press SELECT 3 Press the V A arrows to select INTERNAL EXTERNAL or NONE 4 Press SELECT to accept change NOTE If setting BGM source to INTERNAL then the NTL Studio control software must be used to select the BGM playback content Default Setting BGM EXTERNAL Web Browser Feature on firmware version 07 09 x or higher The iLink LCD has a built in password protected web browser that will display the units serial number firmware version and MAC address This browser will also allow the units communication mode connect back address and port to be changed iLink LCD Configuration Manager Unit Information Serial Number K1132664 Firmware Version 0709X TE MAC Address 00 60 35 11 5a b8 j Status LOGIN OK Current Settings gt New Settings Mode DHCP IP Address 10 1 1 216 o 255 255 255 128 10 1 1 129 Default Gateway Connect Back IP 1 p Connect Back Port 1 Connect Back IP 2 0 0 0 0 80 Connect Back Port 2 Press Submit to make changes to the unit Leave New Settings blank if there is no change When changing Mode either DHCP or STAT
6. IC must be typed in the New Settings column When changing to STATIC mode the IP Subnet and Gateway must all be entered or the settings will not take when submitted The Status will indicate if the settings have been updated to the unit Installation Step 1 Wall or shelf mount the unit Rubber feet and screws are supplied in the accessory kit Step 2 Verify the power switch on the right side of the unit is set to OFF Attach the included power pack to a wall or power strip receptacle then attach the other end to the jack on the right side of the unit labeled 12VDC Step 3 Make sure any amplifiers if using any are turned OFF prior to any connections Step 4 Connect a RCA cable supplied in the accessory kit to the CHANNEL A OUT jack on the left side of the unit Connect the other end of the RCA cable to a phones MOH port PA amplifier or speaker For dual output applications follow the same procedure for the CHANNEL B OUT Step 5 Optional For messaging only applications the existing BGM Background Music can be fed through the iLink Connect the audio source to the CHANNEL A or B IN jack s on the left side of the unit This jack must only be fed signal level audio ANY AMPLIFIED AUDIO WILL DAMAGE THE UNIT Step 6 Connect an Ethernet cable supplied in the accessory kit to the LAN jack on the right side of the unit Connect the other end to a 10 100 speed switch or hub Wiring Diagram Left Side Right Side
7. P and DOWN BUTTONS Keypad buttons used to make changes to selected items 2 x 16 LCD White lettering on blue backlighting LCD used to display unit information LCD Menu y See next page If LOCAL RECORD OPTION is equipped and no IP address can be located after 60 seconds then lt LOCAL MODE ONLY will be displayed on the IP address line If LOCAL RECORD OPTION is equipped then see special LCD Menu for these modes on page 8 of this manual Changes Volume Changes Volume Locked if local volume control is disabled Changes Volume Changes Volume Cycles Internal Speaker to OFF A or B Up to Confirm Down to Cancel Changes Mode gt Select flashes first octet VA Changes digit gt to S p Select confirms and moves to next octet OWD t0 SANGE Select flashes first octet VA Changes digit gt Select confirms and moves to next octet Up to Confirm Down to Cancel Select flashes first octet VA Changes digit gt Select confirms and moves to next octet Up to Confirm Down to Cancel LCD Menu Continued Continued from previous page y Select flashes first octet gt VA Changes digit gt Select confirms and moves to next octet Up to Confirm Down to Cancel Select flashes first octet gt VA Changes digit gt Select confirms and moves to next octet Up to Confirm
8. be allowed for work performed by Buyer or unauthorized parties Out of warranty repairs are invoiced at the current Nel Tech Labs hourly rate plus the cost of parts shipping and handling In the event that the product serial number is missing or has been tampered with in any way the foregoing warranty is void and without effect and Nel Tech Labs shall have no liability whatsoever on account of defects to such product LIMITATIONS Except as stated above there are no warranties express or implied that extend beyond the specifications for the product Nel Tech Labs expressly disclaims any warranty express or implied that equipment sold hereunder is of merchantable quality or that it can be used or is fit for any particular purpose Buyer purchases and accepts equipment solely on the basis of the warranty here in above expressed Under no circumstances shall Nel Tech Labs be liable by virtue of this warranty or otherwise for any special indirect secondary or consequential damages to any person or property arising out of the use or inability to use the product REPAIRING OR REPLACING PRODUCT Buyer may obtain the repair or replacement of any eligible part or equipment covered under this warranty through a Nel Tech Labs dealer only Buyer is responsible for all shipping and handling charges in connection with the performance of this warranty Products returned to Nel Tech Labs must be securely packaged to prevent damage in transit freight prepaid and i
9. n Before you begin installation unpack and verify you have all the correct parts 1 iLink LCD 1 12VDC 500mA power supply 1 Ethernet cable 1 RCA to RCA cable 1 RCA to 3 5mm adapter 2 Wall mount screws 1 Instruction manual 1 Microphone Local Record Option Only If you are missing any of these parts STOP and call your dealer iLink Layout Summary Front of Unit 12VDC This is where the supplied 12VDC 500mA power pack is connected POWER Use this switch to turn the unit ON and OFF MIC Microphone input for Local Recording Optional Uses a standard 1 8 type computer microphone LAN This jack connects to the local Ethernet that allows the iLink connectivity to the Internet The jack also has two built in LEDs that report back network activity and speed status Rear of Unit MADE IN USA CHANNELA Isoon 9 CHANNELB E goon IN OUT 82 IN OUT 82 CHANNEL A or B IN This signal level jack allows an external BGM Background Music source to be fed through the iLink unit CHANNEL A or B OUT This jack connects to a phone systems MOH input or a PA amplifier 8Q or 600Q This switch changes the output impedance of the CHANNEL A or B OUT jack Top of Unit MENU BUTTON Keypad button used to cycle through menu items SELECT BUTTON Keypad button used to select menu item to be changed U
10. nsured for replacement value A return authorization number assigned by Nel Tech Labs must be clearly marked on the outside of the shipping container Proof of purchase must accompany shipment Items delivered to Nel Tech Labs without a return authorization clearly marked on the outside of the shipping container and or without proof of purchase is refused CONTACT Please contact Nel Tech Labs at the address and phone number below to receive a return authorization number and to arrange for the repair or replacement of a flawed part covered by this warranty Please indicate the Product s serial number in all correspondence or a RMA authorization number in the absence of a serial number Nel Tech Labs 4 Ash Street Extension Derry NH 03038 Phone 1 603 425 1096 COPYRIGHT NOTICE Unauthorized or unlicensed use of copyrighted audio content is illegal and Nel Tech Labs Inc takes no responsibility for such action by the user of this equipment FCC Part 15 This equipment has been tested and found to comply within the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of the equi
11. pment in a residential area is likely to cause harmful interference in which case the user will be required to correct interference at his own expense In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio amp television reception Changes or modifications not expressly approved by Nel Tech Labs could void the users authority to operate the equipment IC ES 003 This Class A digital apparatus complies with Canadian ICES 003 C et appareil num rique de la classe A est conform e a la norme NMB 003 du Canada CE CONFORMITY The Nel Tech Labs iLink conforms with the following standards in accordance with the EU Safety EMC Emissions amp EMC Immunities EN 60950 1 2001 EN 55022 1998 for Class A EN 55024 1998 A1 2001 A2 2003 EN 61000 4 2 1995 A1 1998 EN 61000 4 3 1995 EN 61000 4 4 1995 EN 61000 4 5 1995 EN 61000 4 6 1996 EN 61000 5 11 1994 C 15 Nel Tech Labs Inc 4 Ash Street Extension Derry NH 03038 1 800 344 4685 www nel techlabs com ilink led manual Rev E 08 12 Copyright 1984 2012 by Nel Tech Labs Inc
12. rnal Speaker to OFF A or B Step 3 Depending upon the device the 80 6000 switch may need to be pushed to better match the impedance of the device the iLink is driving MADE IN USA CHANNEL A E soon CHANNEL B E soon On OE n IN OUT m8 IN OUT m8 tot Step 4 Adjustment of the stored audio output level can be done through the LCD and Menu Depending upon the application either call into the phone system and be placed on hold OR listen to the PA systems speakers to fine tune volume VA Changes Volume If you see a LOCKED VOLUME SETTINGS message then the dealer has locked this setting Step 5 All volume adjustments are applied live so changes are saved to the unit instantly 12 Channel A amp B Input BGM Feedthrough Level Adjustments Optional Step 1 Plug feed from an unamplified external background music source to the CHANNEL A or B IN MADE IN USA CHANNEL A H soon CHANNEL B E soon a n IN OUT m8 IN OUT m8 and or Step 2 Verify the unit is playing audio by listening to the internal monitor speaker VA Cycles Internal Speaker to OFF A or B Step 3 Adjustment of the background music feedthrough level can be done through the LCD and Menu De pending upon the application either call into the phone system and be placed on hold OR listen to the PA sys tems speakers to fine tune volume VA Changes